HomeMy WebLinkAboutLetter; Response to CommentsArchitecture, Planning P.O. Box 529 Telephone 251.947.3864
Interiors, Construction Administration Robertsdale, Alabama 36567 Fax 251.947.3138
ADAMS STEWART
ARCHITECTS, LLC
St. Lucie County Planning and Development
ATTN: Lori Bender
Re: 2007-0528
DG Fort Pierce FL
Aimee Cooper
Comment: 7-30-20 VEG PERMIT E-MAILED TO ERD VEG PAPERWORK, NEED SURVEY,
THEN SEND TO ERD. **VEG PERMIT IN THE ON-LINE VEGETATION FOLDER (SEARCH
"DOLLAR GENERAL"). FEE LOADED. Response: Please attached survey.
Lori Bender
Comment: THE CODE SECTIONS REFERENCED ON THE PLANS DO NOT COMPLY WITH
FCB 6TH ED 2017 PLEASE REVIEW AND RESUBMIT. SECTION 107.2 FBC 6TH ED 2017.
Response: This has now been revised on Sheet T1 Code Information and A01.1 Life Safety.
Comment: THE OCCUPANCY LOAD CALCULATIONS ARE INCOMPLETE MISSING
INFORMATION (AREAS) PLEASE REVIEW AND RESUBMIT. SECTION 107 FBC6TH ED
2017. Response: The Table 1004.1.2 has been revised on Sheet T1 Code Information.
Comment: THE DUMPSTER ENCLOSURE REQUIRES A SEPARATE PERMIT.
Response: The separate permits have been applied for and hard copies have been sent. Please
see attached application.
Steven Poreba
Comment: I DO NOT SEE COMPLIANCE WITH SECTION C401.2 FOR LOAD
CALCULATIONS, EQUIPMENT OR DUCT SIZING.
Response: HVAC equipment load calculations have been added to sheet M3. Duct sizing schedule
for the air terminals have been added to sheet Ml.
Andy Wentz
Comment: NEED OCCUPANT LOAD FOR PLUMBING REVIEW 107.2 FBC 6TH EDITION
2017. t
Response: Occupany load has been added to sheet P1.
Comment: NEED TO SHOW TEMPERING VALVES ON HOT WATER SYSTEM. 607.1.2 FBC
6TH EDITION 2017
Response: Water heater schedule has been revised on sheet P1 to show limiting device for EWH-1
that serves the lavatories with temp set to 110 deg F. EWH-2 serves the mop sink and requires 140
deg F. A detail has been added showing installation of the temp limiting device.