HomeMy WebLinkAbout7-20-20 REKUS-SIGNEDPOOL SPECIFICATIONS 44'-0" MAX. WIDTH 14'0" MAX.LENGTH 28'0" PERIMETER 75' AREA 315 sq.ft. MIN. DEPTH 3'6" MAX DEPTH 5'6" ACCESS RIGHT ELEV. TOB T.B.D. EXCAVATIED DIRT HAUL RAISED BEAM N/A TILE 6x6 STEP EDGE 2x6 COPING EDGE OVERPOUR INTERIOR FINISH GEM COAT SWIMOUT (1) LADDER N/A HANDRAIL NO GRAB RAIL NO FILTER PENTAIR C&C TIMECLOCK N/A CIRC. PUMP PENTAIR SUPERFLO VS POOL DRAIN 302 CHANNEL DRAIN MODEL#CMP25506-320 POOL RETURNS 4 VAC. LINE STUBOUT SKIMMER (1)TILED 2"—DECK _JETS----------T----------------- I - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - --------, CHLORINATOR IC30 ------------ ----- ----- -- ---------------------------2--SHEER -DESCENT-------L------------------- r-'�r- r- "' -- - F-- ----� � FILL LINE N/A OVERFLOW N/A I co I \ l WATERFEATURE (2)BUBBLERS, (2)DECK JETS & R 18 ;+12" , CONCRETE (1)48" SHEER DESCENT +s" +6'9 & LIGHTS POOL Q) LED COLOR GLOBRITE swlM EDGE 48" R SPRAY DECK ELECTRIC BY HORIZON OUT TILE SHEER TRANSFORMER YES J. BOX YES DESCENT I HEATER NO SIZE ------ btu POOL GUARD GEM GAS TYPE N/A TANK N/A COLOR ALARM 3 6 HOOKUP BY N/A LED LITE 14 x28i INTERIOR 7 DEEP PATIO SPRAY DECK SQ FT ±893 POOL TERMITE YES DONE BY BUGMAN 00 EXISTING PATIO NO SQ FTDGE ±---- N ! 5'6" STILE 1499 N DECK DRAIN 46' PLANTERS NO DEEP APPROX. GALLONS 10,600 G.P.M. -- 00 1 s TURNOVER 6 HR. 0 MIN. SUN R --- n SHELF SCREEN ENCLOSURE YES FOOTERS YES R CHILD BARRIER SPLASH GUARD ALARM & \ SCREEN ENCLOSURE 00 x z w � C —n w Digitally signed by Marvin R Rodgers Marvin R DIN: c=US, o=Unaffiliated, ou=AO141 00000001 725 Rodgers cn=DatMRodgers 2020 OR Rod 23:46:49-04'00' JOB INFORMATION: HORIZON POOLS REKUS RESIDENCE 7437 BOB 0 LINK WAY PORT ST LUCIE, FL M. RANDALL RODGERS, P.E. FL License No.68212 1801 Hazelwood Drive Ft Pierce, FL 34982 (772)201-1634 ***ELECTRIC NOT INCLUDED*** FBC 2017 Compliance NEC 2017 Compliance PREPARED BY: Mitt 1: STEVE HORST 1 DRAFTING & DESIGN SERVICES (772)201-7846 horst.steve@yahoo.com 4 Pool construction complies with FBC 2017. ANSI-7. ANSI-15 —Water Velocity —Max 8ft/sec as per FBC 2017—R4501.6.3 —Pool Barrier to comply with Section R4501.17-6th edition FBC —Skimmers comply with FBC 2017—R4501.21.2 —Soil bearing capacity assumed 2,000psi @95% compaction —Equipment Foundation 3'x7' conc. slab min 3.5" thick pour in Dlace or CIDDroved Hurricane Rated precast eauiDment Dads WHEN PROVIIDED SHALL BE AT 20" MAX BELOW THE WATERLINE SWIMOUTS (NO SCALE) PRESSURE GAUGES INSTALLED ON FILTER PUMP FOR FINAL INSPECTION ll�Ell X 3�`c S O N Vacuum (In Hg) X 1.13 Feet Of Head HYDRO —STATIC RELIEF DEVICE INSTALLED IN AREAS THAT EXCEED 1' WATER TABLE IN SHELL TO GRAVEL BED MAIN DRAIN POOL DETAIL (NO SCALE) ': -4F Ell Pressure (PSI) X 2.31 Feet Of Head Vacuum Head + Pressure Head = Total Dynamic Head #8 COPPER TO GRID HORIZONTAL INSTALL #8 COPPER TO GRID VERTICAL INSTALL PoolBond PB-2008 Install in Plumbing T at least 3" Below Water level in Return Piping.lnstall in sprinkler box for easy access WATER BOND DETAILS FOR NICHLESS LIGHT SYSTEM OUTSIDE ANGLE OF REPOSE 6' AND FURTHER — 4" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 3' TO 6' — 6" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 0' TO 3' — 8" THICK WALLS W/#3 REBAR 012" O.C. EACH WAY 9 ft. 6 ft. -J J J : ' CO oo ; P Y Y QO EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE F� SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT * NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES * COMPACTION TEST OF THE BACKFILLED MATERIAL ARE PROVIDED PRIOR TO THE POURING OF THE PATIO NOTE: REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP OVERPOUR 0 LINE WHEN EMPTYING POOL WHERE 6"x6 GRATE SHALL BE SECURED IN IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL Y" PER FT. MIN SLOPE R CAP TILE APPLICABLE •. .'�. ,�; " TILE 4" SLAB TERIOR 2500 FIBER MIX FINISH 4y" TYP. WALL-3,000 PSI GUNITE 6" TYP. FLOOR TRENCH DRAIN 3,000 PSI GUNITE TREADED PLUG STEEL—TEX FORM OR KRAFT WALL #3 @ 12" O.C.B.W. NOTE: FOR DEPTHS GREATER THAN 6' ADD (1)#3 COVE BAR @6" O.0 GRAVEL BE TO PUMP TYP. WALL SECTION & WELL POINT (NO SCALE) WATER LEVEL UNDERWATER LIGHT POOL LIGHT JUCTION BOX POOL PATIO cZ cfl Z — 12 VAC FROM POWER SUPPLY SIZE AS DETERMINED BY LICENSED ELECTRICIAN YARD BY EQUIPMENT POOL FINISH ` 1 " PVC SCHEDULE 40 PVC SLEEVE CONDUIT NO BONDING OR GROUND REQUIRED NICHLESS UNDERWATER LIGHT DETAIL (NO SCALE) • FOOTER DETAIL (NO SCALE) CNNNNEV ORP\N PIPING SCHEMATIC CUSTOM MOLDED PRODUCTS INC. SINGLE CHANNEL DUAL OUTLET PER FRC4501.6.6 COMPLIANT WITH 2017 FLORIDA BUILDING CODE LISTED TO ASME/ANSI A112.19.8 32" CHANNEL DRAIN AND SUMP 25506-320-000 *THREE 2" SOCKET x 2.5" SPIGOT PORTS *DEBRIS GUARD INCLUDED *38.79in? OPEN AREA *IAMPO LISTED FLOW RATES *WHITE PVC BODY *COVER GOES OVER BODY TO GIVE FINISHED LOOK TO PUMP The maximum flow rating for this suction fitting with the center port plugged and outer ports open is 308 GPM (floor) and 212 GPM (wall) when using 2.5" plumbing and 268 GPM (floor) and 192 GPM (wall) when using 2" plumbing. The maximum flow rating for this suction fitting with the outer ports plugged and the center port open is 200 GPM (floor) and 168 GPM (wall) when using 2.5" plumbing and 184 GPM (floor) and 176 GPM (wall) when using 2" plumbing. HAIR & 1INER CMP 25506-32X VGB COMPLIANT 32" CHANNEL DRAIN RETURN TO POOL MISC. NOTES THREE—WAY 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2x6 CAPTILE BORDER OF OPPOSITE WATER TO SHEER VALVE COLOR OF GEM FINISH FOR VISIBILITY DESCENT 2. HANDHOLD TO BE INSTALLED ARE WHERE DECK RAISED +6" ABOVE POOL 10" F4. I 75 <.......FILTER STEP DETAILS 1. TREAD IS MIN OF 10" WIDE. 2, RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED 3. ALL STEPS TO BE SOLID GUNITE 3000 P.S.I. SUCTION FROM POOL STEPS (NO SCALE) TYPICAL SHEER DESCENT DETAIL www.horizonpools.net Wade M. Clarke N Licensed & Insured Lic# RP-0067256 z � - rizon POOLS. INCIIIIIIIII Q%4 ; - ` NEW CONSTRUCTION & REMODELS _ 32 Years &perrence on the Treasure Coast Email: horizonpools@att.net Office: 772.405.1130 DECK 1 ROW OF WATERLINE TILE WATERLINE — ' " LIGHT WALLS MAX 5 — 6 SHALL NOT I #3 STEEL @ 12" O/C E.W. SLOPE 6" THICK GREATER FLOOR SLOPES THAN 11" FLOOR SLOPE SHALL BE REASONABLY UNIFORM AND COMPLY WITH ARTICLES 5.6.1 THRU 5.6.3 THE SLOPE OF THE FLOOR FROM THE SHALOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FOOT 5'-0" 28' ... 0" TYPICAL SECTION THRU POOL (NO SCALE) Pipe Size 6 fps 8fps 1" 16 gpm 0.14' 21 gpm 0,23' 1.5" 37 gpm 0.08' 50 m 0.14' 2" 62 gpm 0.06' 82 gpm 0.10' 2.5" 88 gpr,1 0.05' 117 gpm 0.09' 3" 136 gpm 0.04' 181 gpm 0.07' 4" 1234 gpm 0.03' 313 gpm 0,05' 6" 1534 gpm 0.02' 712 gpm 0.03' Determine System Flow Rate: Minimum Flow Rate Required: 35 gpm per skimmer 1. Calculate Pool Volume: ___M ___ft_XXX_x 7.48(gal/Ft) _ XXX ___gal (Surface Area) (Average Depth) (Volume in gallons) 2. Determine Flow Rate: ___ XXX____ got / ___ XXX - XXX __+___XXX - XXX (Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) (System Flow Rate) Determine Pipe Sizes: Trunk Piping to be_ 2 __inch to keep velocity @ 8 fps max. at_ 82_gpm Maximum System Flow Rate. Return Piping to be 2 __inch to keep velocity @ 8 fps max. at 8?__gpm Maximum System Flow Rate. Main Drain Cover(_____ SEE _ABOVE --- ) System Flow Rate must not exceed approved cover flow rate. (Make and Model) See Engineering Page for Drain Configuration Pump Model PENTAIR SUPERFLO VS H.P. 1.5 Total H.P.=H.P.x service factor. 1 H.p. or more must be 2 speed or variable speed Filter Make PENTAIR C&C Size 150 Filter min. area based on 6hr. turnover flow rate pool gal. / 360 min. = Flow Rate Divide G.P.M. by Cartridge = .375 or Sand =15 or D.E. = 2 Time Controller make ON PUMP Model Controls must operate a minimum of two speeds. The hiaher speed override is not to exceed one normal cvcle or 24 firs, whichever is less HORIZON POOLS REKUS RESIDENCE 7437 BOB 0 LINK WAY PORT ST LUCIE, FL M. RANDALL RODGERS, P.E. FL License No. 68212 1801 Hazelwood Drive Ft Pierce, FL 34982 (772)201-1634 ***ELECTRIC NOT INCLUDED*** PREPARED BY: SHEET: STEVE HORST 3 DRAFTING & DESIGN SERVICES 4 (772)201.7846 horst.steve@yahoo.com r PENTAIR TDH CALCULATOR HORIZON-REKUS-HIGH I I STEP 1 STEP 2 STEP 3 POOL SPECIFICATIONS SELECT EQUIPMENT TON CALCULATION I I I I STEP 3 OF 3: TDH CALCULATION I I I I Pool Specifications i Pool Volume Igallons): 10600.00 gallons Suction Lift: 1.50 it Turn Over (hours]: 6.00 hours Filtration Flow Rate: 36.00 GPM Maximum Flow Rate 68.05 GPM Selected Components EDIT SELECTION QUANTITY MAXIMUM PIPE VELOCITY (FT/SEC) SUCTION OUTLET 8 [CONSULT YOUR LOCAL COOEI DISCHARGE 8 15' X T' SWAY VALVE 7 TOTAL PIPING LENGTHS (FT) INLET 46.00 DISCHARGE 90.00 SELECTION QUANTITY MAIN DRAIN 1 90 DEGREE ELBOW INLET % DISCHARGE 13 ❑� 1/2INCH RETURN 4 TEE THROUGH INLET O NOIMAGE AVALABLF DISCHARGE 3 ICHLOR 30 1 45 DEGREE ELBOW i INLET 0 ♦`�YI DISCHARGE fi CLEAN AND CLEAR 1 SELECTION / MODEL QUANTITY SUPERFLO VS L 1 Results: Your TDH Calculation Results: Your TDH Calculation Flow Rate 68.05GAL/MIN Max Flow Rate at Max RPM: 68.05GAL/MIN Head Loss 52.08 FT Head Loss at Max Flow Rate at Max 52.08 FT RPM: ___________________________________________________________________________________ REQUIRED MINIMUM PIPE SIZE Inlet Piping: 2.00 Discharge Piping: 2.00 PUMP RPM Flow Rate at Selected Pump RPM: 68.05 Pump RPM: 3450 Head Loss at Selected Pump RPM: 52.08 SYSTEM HEAD PRESSURE CURVE BY PU VIP SELECTION 130 120 110 2 0 100 a 0 90 0 f I 80 a m v 70 ., m l7 3 60 o B so 0 a m = 40 'w 30 v ' Q 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Volumetric Flow Rate (GPM) -Clean System Curve -Pump Curve ■ Desired Operation Point - Clean System A Pump Operation Point I%PSPThe Association of Poo/ & Spa Professionals® HORIZON-REKUS-LOW ANSVAPSPACC 15a ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS PROJECT NAME: AND ADDRESS REKUS CONTRACTOR NAME AND ADDRESS: HORIZON OWNER: CONTRACTOR PHONE: DATE: 7-21-20 This information sheet was prepared by the APSP-15 Residential Swimming Pool and Spa Energy Efficiency Standard Writing Committee of the Association of Pool and Spa Professionals (APSP). It is not part of the American National Standard ANSI/APSP/ICC-15a 2011 but is included for information only. Contractors should acquire and comply with the ANSI/APSP/ICC-15a 2011 standard which ran be purchased at www.apsp.org. I 1. §5.2.1: Calculated pool volume I I a. Gallons: 10,600 ; or 1. 10,600 gallons b. Calculated Gallons: (surface area) X (average depth) X 7.48 (gal/ft43) = I 2. §5.2.1: Calculated filtration flow rate 2. 36 gpm I (Pool volume a 360 or 36gpm whichever is larger) I 3. §5.5.1: Pipe sizing: a. Minimum suction pipe diameter 3a. 1.5 inches (Enter the smallest pipe size from Table 1 with a 5 fps flow capacity the some or more than item 2.) j b. Minimum suction branch pipe diameter 3b. N/A inches (Calculate: Item 2. _(gpm) _ Branch Pipes _(quantity) = branch flow rate (gpm). Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the some or more than the calculated suction branch flow rate.) c. Minimum return pipe diameter 3c. 1.5 inches (Enter the smallest pipe size from Table I with a 8 fps flow capacity the some or more than item 2.) d. Minimum return branch pipe diameter 3d. N/A inches I (Calculate: Item 2. _(gpm) Branch Pipes (quantity)=branch flow rate (gpm). I Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the some or more than the calculated return branch flow rate.) 4. §5.4.1: Filter type and size: I a. Filter type: (Cartridge, DE, Sand) 4a. CART b. Minimum filter area 4b g6 sq. ft. (Calculate: item 2. (gpm) a filter factor (gpm/f A2)) Filter factars: Cartridge=0.375, Sand=15, Diatomaceous Earth=2 S. §5.4.2: Backwash valve: N/A _Yes, ­X-No? (When using a backwash valve, enter result of item 3c or 2 inches whichever is larger) S. inches (wh`.O"�) Table 1 I I I 6. Single -speed pump selection (when used): I §5.1A, 5.3.1: For single -speed pumps with a total horsepower 0.99 or less, find and enter a compliant pump from the Pool Pump Database. I a. Pump model 6a. N/A I b. Total horsepower 6b. N/A 7, Multi -speed pump selection (when used): I §5.3.2.1: Pools 17,000 gallons or less, select pump • from the database with a Curve -A gpm flow equal to item 2 or less. §5.3.2.2: Pools 17,001 gallons or more, select pump' from the database with a Curve-C gpm flow equal to item 2 or less. or 'Multi -speed pumps must have one speed listed that satisfies this requirement. PENTAIR a. Pump model SUPERFLO VS 7a. b. Pump flow 7b. 45 gpm (§5.3.2.1, 5.3.2.2: Applicable Curve A or C gpm flow listed in database) I I I I 3/17/15ANSI/APSP/ICC- 15 Standard Writing Committee Form 1 of 2 j ---------------- --------__---- ANSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS I I I I Pipe Site: t.5" 2" 2.5" 3" J.5" 1" 5" 6" Nominal GPM 6 fps 38 63 90 138 185 238 374 540 Nominal GPM @ 8 fps 51 84 119 184 247 317 499 720 Component Section Requirements Check 4.4.1.1 Heater has no pilot light N/A 4.4.1.2 Readily accessible on -off switch mounted outside of the h Heaters 4.3.1.3 No electric resistance heatin or inground spa with tight fitting cover with R-6 insulation, or for pool with ocumented pool heating from on -site solar or recovered energy. Heater efficiency: gas/oil fired heater efficiency at least 78%, heat pump COP at least 4.0 5.1.1 Pool filter pump listed in database X 5.3.1 Pool filter pump with total horsepower 1.0 or more is multi -speed X Multi -speed pump controller programmed to default to the filtration flow rate when no auxiliary 5.3.3 pool loads are operating within 24 hours and programmed with temporary override capability for X servicing. Pool systems S.3.4 Single -speed pump controller capable of operating pump during off-peak electric demand. N/A 5.5.2 Pipe before pump has at least 4 diameters of straight pipe. X System installed with solar, or setup for the future addition of solar heating equipment by 5.5.3 installing 18 inches of horizontal or vertical pipe after the filter and before a heater, or built-in or X built-up connections, or dedicated pipe to and from the pool. 5.6 Directional inlets for mixing pool water. X I I I I I I I I I I I I I I I I I I I I I I I I I I I � I I I I x I I I I � I I I � I I I I I I I I I I I I I � I I i � I I 3/27/25 ANSI/APSPACC-15 Standard Writing Committee Form 2 of 2 L J a o 0 omomoz a000 gawp a wW_6�c- � z mQ �3�m W �Cst °d10 odt �w 3 KLj =�®aw in3,n A � a w mW� � a ti W � UrwA to Z a >; Z 0 cti t` q ci N O � z'" �CQ o =�o& E ww rEn � <�m< Z ez Ez. x O of 0 a xo � 3 w P. W ai /III\ c X rn z Sce 2 W O O w o v�o a Imo U ~' co � U ww c z cv �80 oo �� EW E" isz 1` M°aw M W E W o ra x�w a w o0 E„ nt rS a o w a. z O �^ z