Applied Wind Pressures Certification:
August 20, 2020
Bill Laprade
Glass Professionals,
Stuart, Florida
Cell: 772-745-3459
Project: Guz Residence
10044 S Ocean Dr. #502
Jensen Beach FL 34957
Dear Mr. Laprade:
For the above address, the replaced impact sliding glass door, Sentinal Series 150 by CGI. The minimum
required wind pressures below are based on FBC 2017 wind load calculations. The applied wind pressures are
as follows per the proposed replacement glazed unit for Exposure D, 50 feet in height: (NOA: 19-0603.03):
Series: Door or Window: Wind Zone: Applied Wind Pressure:
150 (1) 108.375”x80.0” SGD 5 +49.8 / -59.6psf;
In reviewing respective NOA for the above sliding glass door,, the allowable respective design pressures exceed
these respective applied pressures of +60/-60psf minimum allowable, and as such is acceptable to this office.
If you have any questions, please contact me at any time.
Thank you,
Raymond Chladny, B.arch.Sc., M.arch,