Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RUSKOSKY RESIDENCE Builder Name: Street: LOGGERHEAD PLACE LOT #381 Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1260.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1260.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1024.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1024.00 ft2 6. Conditioned floor area above grade (ft2) 1024 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: LAUND 6 300 a. U-Factor: Sgl, U=0.65 141.00 ft2 SHGC: SHGC=0.23 b. U-Factor: NIA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 3.780 ft. Area Weighted Average SHGC: 0.230 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (1024.0 sqft.) Insulation Area EF: 0.950 a. Raised Floor R=19.0 1024.00 ft2 b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 15. Credits Pstat Glass/Floor Area: 0.138 Total Proposed Modified Loads: 43.34 PASS Total Baseline Loads: 44.41 I hereby certify that the plans and specifications covered by Review of the plans and 'TIE S-P this calculation are in compliance with the Florida Energy specifications covered by this - _ �0�, ,Code. calculation indicates compliance -p1.+o, with the Florida Energy Code. rn,,,-;' _ �;,�•;;•,"�;, {O PREPA D Before construction is completed r DATE: this building will be inspected for compliance with Section 553.908 * . I hereby certify that this building, as designed, is in compliance Florida Statutes. 1 �� COD with the Florida Energy Co e. Wf . OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 7 016 11:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software FORM R405-2014 PROJECT Title: RUSKOSKY RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1024 Lot # Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 90 Street: LOGGERHEAD PLACE Permit Office: Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: ST. LUCIE COUNTY, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name- Area Volume 1 Entire House 1024 9216 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 LIVING 343 3087 No 0 1 Yes Yes Yes 2 KITCHEN 156 1404 Yes 0 1 Yes Yes Yes 3 LAUND 42 378 No 0 1 Yes Yes Yes 4 BATH 60 540 No 0 1 Yes Yes Yes 5 BEDROOM 140 1260 No 1 1 1 Yes Yes Yes 6 CLOST 40 360 No 0 1 Yes Yes Yes 7 WIC 45 405 No 0 1 Yes Yes Yes 8 M.BATH 66 594 No 0 1 Yes Yes Yes 9 M BEDROOM 132 1188 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor LIVING 343 ft2 19 1 0 0 2 Raised Floor KITCHEN 156 ft2 19 1 0 0 3 Raised Floor LAUND ____ 42 ft2 19 1 0 0 4 Raised Floor BATH ____ -_ 60 ft2 19 1 0 0 5 Raised Floor BEDROOM 140 ft2 19 1 0 0 6 Raised Floor CLOST 40 ft2 19 1 0 0 7 Raised Floor WIC 45 ft2 19 1 0 0 7/20/2016 11:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Raised Floor M. BATH _--- 66 ft2 19 1 0 0 . 9 Raised Floor M BEDROOM ---- 132 ft2 19 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1079 ft2 170 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1024 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) LIVING 30 Blown 343 ft2 0.1 Wood 2 Under Attic (Vented) KITCHEN 30 Blown 156 ft2 0.1 Wood 3 Under Attic (Vented) LAUND 30 Blown 42 ft2 0.1 Wood 4 Under Attic (Vented) BATH 30 Blown 60 ft2 0.1 Wood 5 Under Attic (Vented) BEDROOM 30 Blown 140 ft2 0.1 Wood 6 Under Attic (Vented) CLOST 30 Blown 40 ft2 0.1 Wood 7 Under Attic (Vented) WIC 30 Blown 45 ft2 0.1 Wood 8 Under Attic (Vented) M. BATH 30 Blown 66 ft2 0.1 Wood 9 Under Attic (Vented) M BEDROOM 30 Blown 132 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Omt Space To Wall TypeR-Value Ft In Ft In Area R-NIallie Eract*on r G 1 N=>E Exterior Concrete Block - Ext Insul LIVING 4.1 13 0 9 0 117.0 ft2 0 0 0.6 0 2 S=>W Exterior Concrete Block - Ext Insul LIVING 4.1 20 0 9 0 180.0 ft2 0 0 0.6 0 3 W=>N Exterior Concrete Block - Ext Insul LIVING 4.1 21 0 9 0 189.0 ft2 0 0 0.6 0 4 N=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 12 0 9 0 108.0 ft2 0 0 0.6 0 5 N=>E Exterior Concrete Block - Ext Insul LAUND 4.1 6 0 9 0 54.0 ft2 0 0 0.6 0 6 S=>W Exterior Concrete Block - Ext Insul BATH 4.1 6 0 9 0 54.0 ft2 0 0 0.6 0 7 S=>W Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 9 0 126.0 f12 0 0 0.6 0 8 E=>S Exterior Concrete Block - Ext Insul CLOST 4.1 5 0 9 0 46.0 ft2 0 0 0.6 0 9 S=>W Exterior Concrete Block - Ext Insul CLOST 4.1 8 0 9 0 72.0 ft2 0 0 0.6 0 10 E=>S Exterior Concrete Block - Ext Insul WIC 4.1 5 0 9 0 45.0 ft2 0 0 0.6 0 11 S=>W Exterior Concrete Block - Ext Insul WIC 4.1 1 0 9 0 9.0 ft2 0 0 0.6 0 12 N=>E Exterior Concrete Block - Ext InsuM. BATH 4.1 6 0 9 0 54.0 ft2 0 0 0.6 0 13 E=>S Exterior Concrete Block - Ext InsuM. BATH 4.1 11 0 9 0 99.0 ft2 0 0 0.6 0 14 N=>E Exterior Concrete Block - Ext IriUBEDROOM 4.1 12 0 9 0 108.0 ft2 0 0 0.6 0 7/20/2016 11:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 1761Vuff tlW&..01v. WINDOWS Orientation shown is the entered orientation (_> changed to Worst Case. # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Overhang Area Depth Separation Int Shade Screening ' 1 2 3 4 5 6 7 8 9 N=>E 1 Metal Low-E Single S=>W 2 Metal Law-E Single S=>W 2 Metal Low-E Single W=>N 3 Metal Low-E Single W=>N 3 Metal Low-E Single N=>E 4 Metal Low-E Single S=>W 7 Metal Low-E Single E=>S 13 Metal Low-E Single N=>E 14 Metal Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.65 0.23 0.65 0.23 0.65 0.23 0.65 0.23 0.65 0.23 0.65 0.23 0.65 0.23 0.65 0.23 0.65 0.23 12.0 ft2 1 ft 0 in 1 ft 4 in 12.0 ft2 1 ft 0 in 1 ft 4 in 16.0 ft2 1 ft 0 in 1 ft 4 in 8.0 ft2 8 ft 0 in 1 ft 4 in 48.0 ft2 8 ft 0 in 1 ft 4 in 9.0 ft2 1 ft 0 in 1 ft 4 in 15.0 ft2 1 It 0 in 1 ft 4 in 6.0 ft2 1 ft 0 in 1 ft 4 in 15.0 ft2 1 ft 0 in 1 ft 4 in None None None None None None None None None None None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000286 768 42.16 79.29 .2087 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 24 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Attic 0.95 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS # - Supply - Location R-Value Area - Return - Location Area Leakage Type Air CFM 25 CFM25 Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 300 ft2 Attic 105 ft2 Default Leakage LAUND (Default) (Default) 1 1 7/20/2016 11:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 F�i7c7 Xri:L�OU&JIS E! TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Heating X Jan Feb Feb Mar f X� Mar [ L_1 j A r Apr Ma May Jun Jun Jul Jul Au Augrj Se [ Sep L j Oct 1Occtt Nov Nov Dec HDecVenting [[ Jan Feb [X Mar lxJ Jun Jul Aug Sep lxJ X� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/20/201611:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: RUSKOSKY RESIDENCE Builder Name: Street: LOGGERHEAD PLACE LOT #381 Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed. separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 7/20/201611:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 = ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. LOGGERHEAD PLACE LOT #381, ST. LUCIE COUNTY, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1260.00 ftz b. N/A R= ft 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 2 d. N/A R= ftz 10. Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1024.00 ftz 6. Conditioned floor area (ftz) 1024 b. N/A R= ftz 7. Windows— Description Area c. N/A R= ftzz a. U-Factor: Sgl, U=0.65 141.00 ftz 11. Ducts a. Sup: Attic, Ret: Attic, AH: LAUND R ft 6 300 SHGC: SHGC=0.23 b. U-Factor: N/A ftz SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ftz a. Central Unit 24.0 SEER:16.00 SHGC: d. U-Factor: N/A ftz 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 3.780 ft. Area Weighted Average SHGC: 0.230 8. Floor Types Insulation Area 14. Hot water systems Cap: 1 gallons a. Raised Floor R=19.0 1024.00 ftz a. Electric EF: 0.95 b. N/A R= ftz b. Conservation features c. N/A R= ftz None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. ,f Builder Signature: Date: I Address of New Ho E�'�J1!` �� City/FL Zip: �l r J- - *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/20/2016 11:39 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 �' -. , teY� sp p'' d gL ` *f �' � �r�'"' c. 9 i e" . `� �' �. .o o e . � e 3 a' v2�:�r r� �a o. c "` ✓��.� 100-1 70 :series Block Impact Single-Hung-21271MPACT - $492.04 2 $984.08 35.875 x 61.875 Installation Zip Code = 32960 U S ENERGY STAR® Climate Zone = Southern ENERGY STAR Required = No i Standard Width = RO: 36 3/8" UNIT: 35 7/8" Standard Height = RO: 62 3/8" UNIT: 617/8" J Frame Width = 35 7/8 Frame Height = 617/8 Tip To Tip Flange Width = 36.875 Tip To Tip Flange Height = 62.875 Unit Code = 2x5 Exterior Color = Beige Interior Finish Color = Beige_ Performance Grade (PG) Rating = PG55 Glass Construction Type = Dual Pane Glass Option = Low-E Sun Argon High Altitude Breather Tubes = No Glass Strength = Impact Resistant Glass Tint = No Tint Specialty Glass = None f Gas Fill = Argon None I d C I /F' ' h—B ' Har ware o or mis — eige Number of Sash Locks = Double t 35 7/8 T Lock Type = Standard --- - RO - 36 31$ Insect Screen Type = Half Screen Insect Screen Material = Fiberglass Re -Order Item = No Room Location = None Unit U-Factor = 0.34 Unit Solar Heat Gain.Coefficient (SHGC) = 0.23 �1 � Tf 6cn U.S,ENERGY STAR Certified = Yes ( Y -_ .Florida Product Approval Number (FL#) =14911 High'Velocity Hurricane Zone (HVHZ) = Yes Cl 'ar.Opening Width = 31.5625 j R Ens 9 Clear Opening Height = 24.375 Clear Opening Area = 5.342611 SKU=1000026796 SEP 0 2 2016 Vendor Name = S/O SILVER LINE BLDG PRD I Vendor Number = 60660514 i PER1fiITTi�dG Customer Service = (888) 888-7020 1 St. Lucie County, EL Catalog Version Date = 08/02/2016 I i www.HomeDepot.com Page 2 of 14 Printed By: DAVID Coo C7 "� Date. Printed: 8/30/2016 10:45 AM 200-1 70 -Series Block Impact Single -Hu ng-21271MPACT - 35.875 x 49.5 Installation Zip Code = 32960 U.S. ENERGY STAR® Climate Zone = Southern ENERGY STAR Required = No Standard Width = RO: 36 3/8" 1 UNIT: 35 7/8" Standard Height = RO: 50" 1 UNIT: 49 1/2" Frame Width = 35 7/8 Frame Height = 49 1/2 Tip To Tip Flange Width = 36.875 Tip To Tip Flange Height = 50.5 Unit Code = 2x4 Exterior Color = Beige Interior Finish Color = Beige Performance Grade (PG) Rating = PG55 Glass Construction Type = Dual Pane Glass Option = Low-E Sun Argon High Altitude Breather Tubes = No Glass Strength = Impact Resistant Glass Tint = No Tint Specialty Glass = None Gas Fill = Argon None Hardware Color/Finish = Beige Number of Sash Locks = Double Lock Type = Standard Insect Screen Type = Half Screen Insect Screen Material = Fiberglass Re -Order Item = No Room Location = None Unit U-Factor = 0.34 Unit Solar Heat Gain Coefficient (SHGC) = 0.23 U.S. ENERGY STAR Certified = Yes Florida Product Approval Number (FL#) =14911 High Velocity Hurricane Zone (HVHZ) = Yes Clear Opening Width = 31.5625 Clear Opening Height=18.1875 Clear Opening Area = 3.986409 SKU = 1000026796 Vendor Name = S/O SILVER LINE BLDG PRD Vendor Number = 60660514 Customer Service = (888) 888-7020 Catalog Version Date = 08/02/2016 $430.70 2 $861.40 r— 35 718 i f---- RO - 36 318 --- i www.HomeDepot.com Page 3 of 14 Printed By: DAVID Date Printed: 8/30/201610:45 AM 11 300-1 70 Series Block Impact Single-Hung-21271MPACT 35.875 x 37.25 Installation Zip Code = 32960 U.S. ENERGY STAR® Climate Zone = Southern ENERGY STAR Required = No Standard Width = RO: 36 3/8" UNIT: 35 7/8" Standard Height = RO: 37 3/4" UNIT: 37 1/4" Frame Width = 35 7/8 Frame Height = 371/4 Tip To Tip Flange Width = 36.875 Tip To Tip Flange Height = 38.25 Unit Code = 2x3 Exterior Color = Beige Interior Finish Color = Beige Performance Grade (PG) Rating = PG55 Glass Construction Type = Dual Pane Glass Option = Low-E Sun Argon High Altitude Breather Tubes = No Glass Strength = Impact Resistant Glass Tint = No Tint Specialty Glass = None Gas Fill = Argon None Hardware Color/Finish = Beige Number of Sash Locks = Double Lock Type = Standard Insect Screen Type = Half Screen Insect Screen Material = Fiberglass Re -Order Item = No Room Location = None Unit U-Factor = 0.34 Unit Solar Heat Gain Coefficient (SHGC) = 0.23 U.S. ENERGY STAR Certified = Yes Florida Product Approval Number (FL#) =14911 High Velocity Hurricane Zone (HVHZ) = Yes Clear Opening Width = 31.5625 Clear Opening Height=12.0625 Clear Opening Area = 2.643907 SKU=1000026796 Vendor Name = S/O SILVER LINE BLDG PRD Vendor Number = 60660514 Customer Service = (888) 888-7020 Catalog Version Date = 08/02/2016 $369.42 1 $369.42 CO m� o 35 7I8 --- t--- RO - 36 318 --- —®-� www.HomeDepot.com Page 4 of 14 Printed By: DAVID Date Printed: 8/30/2016 10:45 AM 400-1 70Series Block Impact Single-Hung-21271MPACT 52 x 49.5 Installation Zip Code = 32960 U.S. ENERGY STAR® Climate Zone = Southern ENERGY STAR Required = No Standard Width = RO: 52 1/2" 1 UNIT: 52" Standard Height = RO: 50" 1 UNIT: 49 1/2" Frame Width = 52 Frame Height = 49 1/2 Tip To Tip Flange Width = 53 Tip To Tip Flange Height = 50.5 Unit Code = 3x4 Exterior Color = Beige Interior Finish Color = Beige Performance Grade (PG) Rating = PG55 Glass Construction Type = Dual Pane Glass Option = Low-E Sun Argon High Altitude Breather Tubes = No Glass Strength = Impact Resistant Glass Tint = No Tint Specialty Glass = None Gas Fill = Argon None Hardware Color/Finish = Beige Number of Sash Locks = Double Lock Type = Standard Insect Screen Type = Half Screen Insect Screen Material = Fiberglass Re -Order Item = No Room Location = None Unit U-Factor = 0.34 Unit Solar Heat Gain Coefficient (SHGC) = 0.23 U.S. ENERGY STAR Certified = Yes Florida Product Approval Number (FL#) =14911 High Velocity Hurricane Zone (HVHZ) = Yes Clear Opening Width = 47.6875 Clear Opening Height = 16.938 Clear Opening Area = 5.609242 SKU = 1000026796 Vendor Name = S/O SILVER LINE BLDG PRD Vendor Number = 60660514 Customer Service = (888) 888-7020 Catalog Version Date = 08/02/2016 $515:15 1 $515.15 Q o 52 ------- RO - 52 112 www.HomeDepot.com Page 5 of 14 Printed By: DAVID i Date Printed: 8/30/2016 10:45 AM ; 500-1 70'Series Block Impact Single-Hung-21271MPACT - $318.02 1 $318.02 25.375 x 37.25 i Installation Zip Code = 32960 U.S. ENERGY STAR® Climate Zone = Southern ENERGY STAR Required = No Standard Width = RO: 25 7/8" UNIT: 25 3/8" Standard Height = RO: 37 3/4" UNIT: 371/4" Frame Width = 25 3/8 Frame Height = 37 1/4 Tip To Tip Flange Width = 26.375 Tip To Tip Flange Height = 38.25 Unit Code =1/2 3x3 Exterior Color = Beige m Interior Finish Color = Beige cri Performance Grade (PG) Rating = PG55 Glass Construction Type = Dual Pane Glass Option = Low-E Sun Argon High Altitude Breather Tubes = No Glass Strength = Impact Resistant Glass Tint = No Tint Specialty Glass = None Gas Fill = Argon �t .Sa �1 None Hardware Color/Finish =Beige 25318 —� Number of Sash Locks = Double F-- RO - 25 7/8 ---- i! Lock Type = Standard Insect Screen Type = Half Screen Insect Screen Material = Fiberglass Re -Order Item = No Room Location = None Unit U-Factor = 0.34 Unit Solar Heat Gain Coefficient (SHGC) = 0.23 I ` U.S. ENERGY STAR Certified = Yes Florida Product Approval Number (FL#) =14911 High Velocity Hurricane Zone (HVHZ) = Yes Clear Opening Width = 21.0625 Clear Opening Height =13.5 Clear Opening Area=1.974609 SKU=1000026796 Vendor Name = S/0 SILVER LINE BLDG PRD Vendor Number = 60660514 I bj Customer Service = (888) 888-7020 i { Catalog Version Date = 08/02/2016 I Date Printed: 8/30/2016 10:45 AM www.HomeDepot.com Page 6 of 14 Printed By: DAVID 600-1 705eries Block Impact Single-Hung-21271MPACT 25.375 x 49.5 Installation Zip Code = 32960 U.S. ENERGY STAR® Climate Zone = Southern ENERGY STAR Required = No Standard Width = RO: 25 7/8" 1 UNIT: 25 3/8" Standard Height = RO: 50" 1 UNIT: 49 1/2" Frame Width = 25 3/8 Frame Height = 49 1/2 Tip To Tip Flange Width = 26.375 Tip To Tip Flange Height = 50.5 Unit Code =1/2 3x4 Exterior Color = Beige Interior Finish Color = Beige Performance Grade (PG) Rating = PG55 Glass Construction Type = Dual Pane Glass Option = Low-E Sun.Argon High Altitude Breather Tubes = No Glass Strength = Impact Resistant Glass Tint = No Tint Specialty Glass = None Gas Fill = Argon None Hardware Color/Finish = Beige Number of Sash Locks = Double Lock Type = Standard Insect Screen Type = Half Screen Insect Screen Material = Fiberglass Re -Order Item = No Room Location = None Unit U-Factor = 0.34 Unit Solar Heat Gain Coefficient (SHGC) = 0.23 U.S. ENERGY STAR Certified = Yes Florida Product Approval Number (FL#) =14911 High Velocity Hurricane Zone (HVHZ) = Yes Clear Opening Width = 21.0625 Clear Opening Height=18.1875 Clear Opening Area = 2.660238 SKU=1000026796 Vendor Name = S/O SILVER LINE BLDG PRD Vendor Number = 60660514 Customer Service = (888) 888-7020 Catalog Version Date = 08/02/2016 a $377.65 1 $377.65 �-- 25318 t- --- - RO - 25 718 --�--a www.HomeDepot.com Page 7 of 14 Printed By: DAVID Date Printed: 8/30/2016 10:45 AM J H 700-1 74x80.375 Fiberglass Double Door Unit Active/Inactive no $1,998.02 1 $1,998.02 Outswin g e"woovn' Call Width =72 Call Height = 80 Frame Width = 74 Frame Height = 80.375 Door Glass Insert Size & Shape = 22 x 64 Rectangle Door Glass Insert Option = Clear / Privacy Grille Designs Door Glass Type = Impact Glass Door Glass Design Options=1-Lite Door Glass Caming = None Door Glazing / Clear or Privacy Type = Insulated Low-E Clear Door Glass Privacy Rating = 1 Unit Spec = All Products Building Code = FBC - Non-HVHZ - NAMI Impact Rating = Wind Zone 3 Missile Level D Energy Star Needed = No Protection for Exterior Door Flyer = No Unit Type = Pre -Hung Handing & Swing = Active/Inactive Outswing Door Skin = Smooth -Pro Door Type = Doors with Inserts Door Thickness = 13/4" Door Style = Flush Full Lite Door Finish Type = None Door Order Method = Store Delivery Brickmould Specie = None Door Glass Grille Type / Color & Profile = None Door Screen Type = No Screen Door Bore = Double Bore Inactive Door Bore = Double Bore Bore Backset = 2 3/8" Bore Diameter = 2 1/8" Lockset Bore Position = 44 Dead Bolt Bore Position = 5 1/2" Hinge Prep = 3-Hinge Prep Hinge Size = 4 x 4-1/4" Hinge Type = Ball Bearing w/Safety Stud Hinge Radius = 5/8" Radius / Square Hinge Finish = Satin Nickel First.Hinge Position = 6 3/4" Second Hinge Position = 36" Third Hinge Position = 65 1/4" Astragal = HD White Aluminum Astragal Location = Inactive Door Security Flange = No Flush Bolts = Flush Bolt Top and Bottom Flush Bolt Finish = Satin Nickel Jamb Width = 4 9/16" Jamb Finish Type = None Jamb Specie = Finger -Jointed Primed Weather -Strip Type = Compression Bronze Sill / Threshold Type = All Aluminum Sill Width = 4 9/16" Sill Finish = Aluminum Room Location = no Is This a Remake = No Specific Information = Sup UFA",l �-0)1 www.HomeDepot.com Page 8 of 14 Printed By: DAVID Date Printed: 8/30/2016 10:45 AI' I Ju ui.�Ul d+ ur ndung = ur rzu/-au Florida Approval Number=16674.4 Door U-Factor = 0 Door Solar Heat Gain Coefficient = 0 SKU=115728 Vendor Name = S/O JELD-WEN DOOR SYSTMS Vendor Number = 60075920. Manufacturer=JELD-WEN, Kissimmee (FL) Customer Service=1.800.246.9131 Catalog Version Date = 08/10/2016 "All prices are subject to change "Customer is responsible for verifying product selections. The Home "All graphics viewed from the exterior Pre -Tax Price: $5,423.74 not accept returns for the above products www.HomeDepot.com Page 9 of 14 Printed By: DAVID Date Printed: 8/30/2016 10:45 AM