HomeMy WebLinkAboutEnergy CodeFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: RUSKOSKY RESIDENCE
Builder Name:
Street: LOGGERHEAD PLACE LOT #381
Permit Office:
City, State, Zip: ST. LUCIE COUNTY, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1260.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1260.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1024.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1024.00 ft2
6. Conditioned floor area above grade (ft2) 1024
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(141.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: LAUND
6 300
a. U-Factor: Sgl, U=0.65 141.00 ft2
SHGC: SHGC=0.23
b. U-Factor: NIA ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
24.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.780 ft.
Area Weighted Average SHGC: 0.230
14. Hot water systems
a. Electric Tankless
Cap: 1 gallons
8. Floor Types (1024.0 sqft.) Insulation Area
EF: 0.950
a. Raised Floor R=19.0 1024.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. NIA R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.138 Total Proposed Modified Loads: 43.34
PASS
Total Baseline Loads: 44.41
I hereby certify that the plans and specifications covered by
Review of the plans and
'TIE S-P
this calculation are in compliance with the Florida Energy
specifications covered by this
- _ �0�,
,Code.
calculation indicates compliance
-p1.+o,
with the Florida Energy Code.
rn,,,-;' _ �;,�•;;•,"�;, {O
PREPA D
Before construction is completed
r
DATE:
this building will be inspected for
compliance with Section 553.908
* .
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
1 ��
COD
with the Florida Energy Co e.
Wf
. OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
7
016 11:34 AM
EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
FORM R405-2014
PROJECT
Title: RUSKOSKY RESIDENCE Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1024
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name:
Rotate Angle: 90
Street:
LOGGERHEAD
PLACE
Permit Office:
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State, Zip:
ST. LUCIE COUNTY,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39
90
70
75 299
62
Low
BLOCKS
Number Name-
Area Volume
1 Entire House
1024 9216
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 LIVING
343 3087 No
0
1 Yes
Yes
Yes
2 KITCHEN
156 1404 Yes
0
1 Yes
Yes
Yes
3 LAUND
42 378 No
0
1 Yes
Yes
Yes
4 BATH
60 540 No
0
1 Yes
Yes
Yes
5 BEDROOM
140 1260 No
1
1
1 Yes
Yes
Yes
6 CLOST
40 360 No
0
1 Yes
Yes
Yes
7 WIC
45 405 No
0
1 Yes
Yes
Yes
8 M.BATH
66 594 No
0
1 Yes
Yes
Yes
9 M BEDROOM
132 1188 No
2
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Raised Floor
LIVING
343 ft2
19
1 0
0
2 Raised Floor
KITCHEN
156 ft2
19
1 0
0
3 Raised Floor
LAUND ____
42 ft2
19
1 0
0
4 Raised Floor
BATH ____ -_
60 ft2
19
1 0
0
5 Raised Floor
BEDROOM
140 ft2
19
1 0
0
6 Raised Floor
CLOST
40 ft2
19
1 0
0
7 Raised Floor
WIC
45 ft2
19
1 0
0
7/20/2016 11:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Raised Floor M. BATH
_---
66 ft2
19
1
0
0
.
9 Raised Floor M BEDROOM
----
132 ft2
19
1
0
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Gable or Shed Composition shingles 1079 ft2
170 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
300
1024 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented) LIVING
30
Blown
343 ft2
0.1
Wood
2
Under Attic (Vented) KITCHEN
30
Blown
156 ft2
0.1
Wood
3
Under Attic (Vented) LAUND
30
Blown
42 ft2
0.1
Wood
4
Under Attic (Vented) BATH
30
Blown
60 ft2
0.1
Wood
5
Under Attic (Vented) BEDROOM
30
Blown
140 ft2
0.1
Wood
6
Under Attic (Vented) CLOST
30
Blown
40 ft2
0.1
Wood
7
Under Attic (Vented) WIC
30
Blown
45 ft2
0.1
Wood
8
Under Attic (Vented) M. BATH
30
Blown
66 ft2
0.1
Wood
9
Under Attic (Vented) M BEDROOM
30
Blown
132 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
#
Omt
Space
To Wall TypeR-Value
Ft In
Ft
In
Area R-NIallie
Eract*on
r G
1
N=>E
Exterior Concrete Block - Ext Insul LIVING
4.1 13
0 9
0
117.0 ft2
0
0
0.6
0
2
S=>W
Exterior Concrete Block - Ext Insul LIVING
4.1 20
0 9
0
180.0 ft2
0
0
0.6
0
3
W=>N
Exterior Concrete Block - Ext Insul LIVING
4.1 21
0 9
0
189.0 ft2
0
0
0.6
0
4
N=>E
Exterior Concrete Block - Ext InsuKITCHEN
4.1 12
0 9
0
108.0 ft2
0
0
0.6
0
5
N=>E
Exterior Concrete Block - Ext Insul LAUND
4.1 6
0 9
0
54.0 ft2
0
0
0.6
0
6
S=>W
Exterior Concrete Block - Ext Insul BATH
4.1 6
0 9
0
54.0 ft2
0
0
0.6
0
7
S=>W
Exterior Concrete Block - Ext Ins®EDROOM
4.1 14
0 9
0
126.0 f12
0
0
0.6
0
8
E=>S
Exterior Concrete Block - Ext Insul CLOST
4.1 5
0 9
0
46.0 ft2
0
0
0.6
0
9
S=>W
Exterior Concrete Block - Ext Insul CLOST
4.1 8
0 9
0
72.0 ft2
0
0
0.6
0
10
E=>S
Exterior Concrete Block - Ext Insul WIC
4.1 5
0 9
0
45.0 ft2
0
0
0.6
0
11
S=>W
Exterior Concrete Block - Ext Insul WIC
4.1 1
0 9
0
9.0 ft2
0
0
0.6
0
12
N=>E
Exterior Concrete Block - Ext InsuM. BATH
4.1 6
0 9
0
54.0 ft2
0
0
0.6
0
13
E=>S
Exterior Concrete Block - Ext InsuM. BATH
4.1 11
0 9
0
99.0 ft2
0
0
0.6
0
14
N=>E
Exterior Concrete Block - Ext IriUBEDROOM
4.1 12
0 9
0
108.0 ft2
0
0
0.6
0
7/20/2016 11:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
1761Vuff tlW&..01v.
WINDOWS
Orientation shown is the entered orientation (_> changed to Worst Case.
#
Wall
Ornt ID Frame Panes
NFRC
U-Factor SHGC
Overhang
Area Depth Separation
Int Shade
Screening
' 1
2
3
4
5
6
7
8
9
N=>E 1 Metal Low-E Single
S=>W 2 Metal Law-E Single
S=>W 2 Metal Low-E Single
W=>N 3 Metal Low-E Single
W=>N 3 Metal Low-E Single
N=>E 4 Metal Low-E Single
S=>W 7 Metal Low-E Single
E=>S 13 Metal Low-E Single
N=>E 14 Metal Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.65 0.23
0.65 0.23
0.65 0.23
0.65 0.23
0.65 0.23
0.65 0.23
0.65 0.23
0.65 0.23
0.65 0.23
12.0 ft2 1 ft 0 in 1 ft 4 in
12.0 ft2 1 ft 0 in 1 ft 4 in
16.0 ft2 1 ft 0 in 1 ft 4 in
8.0 ft2 8 ft 0 in 1 ft 4 in
48.0 ft2 8 ft 0 in 1 ft 4 in
9.0 ft2 1 ft 0 in 1 ft 4 in
15.0 ft2 1 It 0 in 1 ft 4 in
6.0 ft2 1 ft 0 in 1 ft 4 in
15.0 ft2 1 ft 0 in 1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000286
768 42.16 79.29 .2087 5
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
None
COPA
17 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit
Split
SEER: 16
24 kBtu/hr cfm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric Tankless
Attic
0.95 1 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
#
- Supply -
Location R-Value Area
- Return -
Location Area Leakage Type
Air CFM 25 CFM25
Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1
Attic 6 300 ft2
Attic
105 ft2 Default Leakage
LAUND (Default) (Default)
1 1
7/20/2016 11:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
F�i7c7 Xri:L�OU&JIS E!
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan
Heating X Jan
Feb
Feb
Mar
f X� Mar
[
L_1
j A r
Apr
Ma
May
Jun
Jun
Jul
Jul
Au
Augrj
Se [
Sep L
j Oct
1Occtt
Nov
Nov
Dec
HDecVenting
[[ Jan
Feb
[X Mar
lxJ
Jun
Jul
Aug
Sep lxJ
X�
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
7/20/201611:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: RUSKOSKY RESIDENCE Builder Name:
Street: LOGGERHEAD PLACE LOT #381 Permit Office:
City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed. separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
7/20/201611:34 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
= ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
LOGGERHEAD PLACE LOT #381, ST. LUCIE COUNTY, FL,
1. New construction or existing
New (From Plans) 9. Wall Types Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Ext Insul, Exterior R=4.1
1260.00 ftz
b. N/A R=
ft
3. Number of units, if multiple family
1 c. N/A R=
ftz
4. Number of Bedrooms
2 d. N/A R=
ftz
10. Ceiling Types Insulation
Area
5. Is this a worst case?
Yes a. Under Attic (Vented) R=30.0
1024.00 ftz
6. Conditioned floor area (ftz)
1024 b. N/A R=
ftz
7. Windows— Description
Area c. N/A R=
ftzz
a. U-Factor: Sgl, U=0.65
141.00 ftz 11. Ducts
a. Sup: Attic, Ret: Attic, AH: LAUND
R ft
6 300
SHGC: SHGC=0.23
b. U-Factor: N/A
ftz
SHGC:
12. Cooling systems kBtu/hr
Efficiency
c. U-Factor. N/A
ftz a. Central Unit 24.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ftz 13. Heating systems kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat 17.0
COP:1.00
Area Weighted Average Overhang Depth:
3.780 ft.
Area Weighted Average SHGC:
0.230
8. Floor Types Insulation Area 14. Hot water systems Cap:
1 gallons
a. Raised Floor R=19.0 1024.00 ftz a. Electric
EF: 0.95
b. N/A R=
ftz
b. Conservation features
c. N/A R=
ftz
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. ,f
Builder Signature: Date: I
Address of New Ho E�'�J1!` �� City/FL Zip: �l r
J- -
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/20/2016 11:39 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
�' -. , teY� sp p'' d gL ` *f �' � �r�'"' c. 9 i e" . `� �' �. .o o e . � e 3 a' v2�:�r r� �a o. c "` ✓��.�
100-1 70 :series Block Impact Single-Hung-21271MPACT - $492.04 2 $984.08
35.875 x 61.875
Installation Zip Code = 32960
U S ENERGY STAR® Climate Zone = Southern
ENERGY STAR Required = No
i
Standard Width = RO: 36 3/8" UNIT: 35 7/8"
Standard Height = RO: 62 3/8" UNIT: 617/8"
J Frame Width = 35 7/8
Frame Height = 617/8
Tip To Tip Flange Width = 36.875
Tip To Tip Flange Height = 62.875
Unit Code = 2x5
Exterior Color = Beige
Interior Finish Color = Beige_
Performance Grade (PG) Rating = PG55
Glass Construction Type = Dual Pane
Glass Option = Low-E Sun Argon
High Altitude Breather Tubes = No
Glass Strength = Impact Resistant
Glass Tint = No Tint
Specialty Glass = None f
Gas Fill = Argon
None
I
d C I /F' ' h—B '
Har ware o or mis — eige
Number of Sash Locks = Double
t 35 7/8 T
Lock Type = Standard
--- -
RO - 36 31$
Insect Screen Type = Half Screen
Insect Screen Material = Fiberglass
Re -Order Item = No
Room Location = None
Unit U-Factor = 0.34
Unit Solar Heat Gain.Coefficient (SHGC) = 0.23
�1 � Tf 6cn
U.S,ENERGY STAR Certified = Yes
( Y -_
.Florida Product Approval Number (FL#) =14911
High'Velocity Hurricane Zone (HVHZ) = Yes
Cl 'ar.Opening Width = 31.5625
j
R Ens 9
Clear Opening Height = 24.375
Clear Opening Area = 5.342611
SKU=1000026796
SEP 0 2 2016
Vendor Name = S/O SILVER LINE BLDG PRD
I
Vendor Number = 60660514
i PER1fiITTi�dG
Customer Service = (888) 888-7020
1 St. Lucie County, EL
Catalog Version Date = 08/02/2016
I
i
www.HomeDepot.com Page 2 of 14 Printed By: DAVID
Coo
C7 "�
Date. Printed: 8/30/2016 10:45 AM
200-1 70 -Series Block Impact Single -Hu ng-21271MPACT
- 35.875 x 49.5
Installation Zip Code = 32960
U.S. ENERGY STAR® Climate Zone = Southern
ENERGY STAR Required = No
Standard Width = RO: 36 3/8" 1 UNIT: 35 7/8"
Standard Height = RO: 50" 1 UNIT: 49 1/2"
Frame Width = 35 7/8
Frame Height = 49 1/2
Tip To Tip Flange Width = 36.875
Tip To Tip Flange Height = 50.5
Unit Code = 2x4
Exterior Color = Beige
Interior Finish Color = Beige
Performance Grade (PG) Rating = PG55
Glass Construction Type = Dual Pane
Glass Option = Low-E Sun Argon
High Altitude Breather Tubes = No
Glass Strength = Impact Resistant
Glass Tint = No Tint
Specialty Glass = None
Gas Fill = Argon
None
Hardware Color/Finish = Beige
Number of Sash Locks = Double
Lock Type = Standard
Insect Screen Type = Half Screen
Insect Screen Material = Fiberglass
Re -Order Item = No
Room Location = None
Unit U-Factor = 0.34
Unit Solar Heat Gain Coefficient (SHGC) = 0.23
U.S. ENERGY STAR Certified = Yes
Florida Product Approval Number (FL#) =14911
High Velocity Hurricane Zone (HVHZ) = Yes
Clear Opening Width = 31.5625
Clear Opening Height=18.1875
Clear Opening Area = 3.986409
SKU = 1000026796
Vendor Name = S/O SILVER LINE BLDG PRD
Vendor Number = 60660514
Customer Service = (888) 888-7020
Catalog Version Date = 08/02/2016
$430.70 2 $861.40
r— 35 718 i
f---- RO - 36 318 --- i
www.HomeDepot.com Page 3 of 14 Printed By: DAVID Date Printed: 8/30/201610:45 AM
11
300-1 70 Series Block Impact Single-Hung-21271MPACT
35.875 x 37.25
Installation Zip Code = 32960
U.S. ENERGY STAR® Climate Zone = Southern
ENERGY STAR Required = No
Standard Width = RO: 36 3/8" UNIT: 35 7/8"
Standard Height = RO: 37 3/4" UNIT: 37 1/4"
Frame Width = 35 7/8
Frame Height = 371/4
Tip To Tip Flange Width = 36.875
Tip To Tip Flange Height = 38.25
Unit Code = 2x3
Exterior Color = Beige
Interior Finish Color = Beige
Performance Grade (PG) Rating = PG55
Glass Construction Type = Dual Pane
Glass Option = Low-E Sun Argon
High Altitude Breather Tubes = No
Glass Strength = Impact Resistant
Glass Tint = No Tint
Specialty Glass = None
Gas Fill = Argon
None
Hardware Color/Finish = Beige
Number of Sash Locks = Double
Lock Type = Standard
Insect Screen Type = Half Screen
Insect Screen Material = Fiberglass
Re -Order Item = No
Room Location = None
Unit U-Factor = 0.34
Unit Solar Heat Gain Coefficient (SHGC) = 0.23
U.S. ENERGY STAR Certified = Yes
Florida Product Approval Number (FL#) =14911
High Velocity Hurricane Zone (HVHZ) = Yes
Clear Opening Width = 31.5625
Clear Opening Height=12.0625
Clear Opening Area = 2.643907
SKU=1000026796
Vendor Name = S/O SILVER LINE BLDG PRD
Vendor Number = 60660514
Customer Service = (888) 888-7020
Catalog Version Date = 08/02/2016
$369.42 1 $369.42
CO
m�
o
35 7I8 ---
t--- RO - 36 318 --- —®-�
www.HomeDepot.com Page 4 of 14 Printed By: DAVID Date Printed: 8/30/2016 10:45 AM
400-1 70Series Block Impact Single-Hung-21271MPACT
52 x 49.5
Installation Zip Code = 32960
U.S. ENERGY STAR® Climate Zone = Southern
ENERGY STAR Required = No
Standard Width = RO: 52 1/2" 1 UNIT: 52"
Standard Height = RO: 50" 1 UNIT: 49 1/2"
Frame Width = 52
Frame Height = 49 1/2
Tip To Tip Flange Width = 53
Tip To Tip Flange Height = 50.5
Unit Code = 3x4
Exterior Color = Beige
Interior Finish Color = Beige
Performance Grade (PG) Rating = PG55
Glass Construction Type = Dual Pane
Glass Option = Low-E Sun Argon
High Altitude Breather Tubes = No
Glass Strength = Impact Resistant
Glass Tint = No Tint
Specialty Glass = None
Gas Fill = Argon
None
Hardware Color/Finish = Beige
Number of Sash Locks = Double
Lock Type = Standard
Insect Screen Type = Half Screen
Insect Screen Material = Fiberglass
Re -Order Item = No
Room Location = None
Unit U-Factor = 0.34
Unit Solar Heat Gain Coefficient (SHGC) = 0.23
U.S. ENERGY STAR Certified = Yes
Florida Product Approval Number (FL#) =14911
High Velocity Hurricane Zone (HVHZ) = Yes
Clear Opening Width = 47.6875
Clear Opening Height = 16.938
Clear Opening Area = 5.609242
SKU = 1000026796
Vendor Name = S/O SILVER LINE BLDG PRD
Vendor Number = 60660514
Customer Service = (888) 888-7020
Catalog Version Date = 08/02/2016
$515:15 1 $515.15
Q
o
52
------- RO - 52 112
www.HomeDepot.com Page 5 of 14 Printed By: DAVID i Date Printed: 8/30/2016 10:45 AM ;
500-1 70'Series Block Impact Single-Hung-21271MPACT - $318.02 1 $318.02
25.375 x 37.25
i
Installation Zip Code = 32960
U.S. ENERGY STAR® Climate Zone = Southern
ENERGY STAR Required = No
Standard Width = RO: 25 7/8" UNIT: 25 3/8"
Standard Height = RO: 37 3/4" UNIT: 371/4"
Frame Width = 25 3/8
Frame Height = 37 1/4
Tip To Tip Flange Width = 26.375
Tip To Tip Flange Height = 38.25
Unit Code =1/2 3x3
Exterior Color = Beige
m
Interior Finish Color = Beige
cri
Performance Grade (PG) Rating = PG55
Glass Construction Type = Dual Pane
Glass Option = Low-E Sun Argon
High Altitude Breather Tubes = No
Glass Strength = Impact Resistant
Glass Tint = No Tint
Specialty Glass = None
Gas Fill = Argon
�t
.Sa
�1
None
Hardware Color/Finish =Beige 25318 —�
Number of Sash Locks = Double F-- RO - 25 7/8 ---- i!
Lock Type = Standard
Insect Screen Type = Half Screen
Insect Screen Material = Fiberglass
Re -Order Item = No
Room Location = None
Unit U-Factor = 0.34
Unit Solar Heat Gain Coefficient (SHGC) = 0.23 I `
U.S. ENERGY STAR Certified = Yes
Florida Product Approval Number (FL#) =14911
High Velocity Hurricane Zone (HVHZ) = Yes
Clear Opening Width = 21.0625
Clear Opening Height =13.5
Clear Opening Area=1.974609
SKU=1000026796
Vendor Name = S/0 SILVER LINE BLDG PRD
Vendor Number = 60660514 I bj
Customer Service = (888) 888-7020 i {
Catalog Version Date = 08/02/2016
I
Date Printed: 8/30/2016 10:45 AM
www.HomeDepot.com Page 6 of 14 Printed By: DAVID
600-1 705eries Block Impact Single-Hung-21271MPACT
25.375 x 49.5
Installation Zip Code = 32960
U.S. ENERGY STAR® Climate Zone = Southern
ENERGY STAR Required = No
Standard Width = RO: 25 7/8" 1 UNIT: 25 3/8"
Standard Height = RO: 50" 1 UNIT: 49 1/2"
Frame Width = 25 3/8
Frame Height = 49 1/2
Tip To Tip Flange Width = 26.375
Tip To Tip Flange Height = 50.5
Unit Code =1/2 3x4
Exterior Color = Beige
Interior Finish Color = Beige
Performance Grade (PG) Rating = PG55
Glass Construction Type = Dual Pane
Glass Option = Low-E Sun.Argon
High Altitude Breather Tubes = No
Glass Strength = Impact Resistant
Glass Tint = No Tint
Specialty Glass = None
Gas Fill = Argon
None
Hardware Color/Finish = Beige
Number of Sash Locks = Double
Lock Type = Standard
Insect Screen Type = Half Screen
Insect Screen Material = Fiberglass
Re -Order Item = No
Room Location = None
Unit U-Factor = 0.34
Unit Solar Heat Gain Coefficient (SHGC) = 0.23
U.S. ENERGY STAR Certified = Yes
Florida Product Approval Number (FL#) =14911
High Velocity Hurricane Zone (HVHZ) = Yes
Clear Opening Width = 21.0625
Clear Opening Height=18.1875
Clear Opening Area = 2.660238
SKU=1000026796
Vendor Name = S/O SILVER LINE BLDG PRD
Vendor Number = 60660514
Customer Service = (888) 888-7020
Catalog Version Date = 08/02/2016
a
$377.65
1 $377.65
�-- 25318
t- --- - RO - 25 718 --�--a
www.HomeDepot.com Page 7 of 14 Printed By: DAVID
Date Printed: 8/30/2016 10:45 AM J
H
700-1 74x80.375 Fiberglass Double Door Unit Active/Inactive
no $1,998.02 1 $1,998.02
Outswin
g
e"woovn' Call Width =72
Call Height = 80
Frame Width = 74
Frame Height = 80.375
Door Glass Insert Size & Shape = 22 x 64 Rectangle
Door Glass Insert Option = Clear / Privacy Grille Designs
Door Glass Type = Impact Glass
Door Glass Design Options=1-Lite
Door Glass Caming = None
Door Glazing / Clear or Privacy Type = Insulated Low-E
Clear
Door Glass Privacy Rating = 1
Unit Spec = All Products
Building Code = FBC - Non-HVHZ - NAMI
Impact Rating = Wind Zone 3 Missile Level D
Energy Star Needed = No
Protection for Exterior Door Flyer = No
Unit Type = Pre -Hung
Handing & Swing = Active/Inactive Outswing
Door Skin = Smooth -Pro
Door Type = Doors with Inserts
Door Thickness = 13/4"
Door Style = Flush Full Lite
Door Finish Type = None
Door Order Method = Store Delivery
Brickmould Specie = None
Door Glass Grille Type / Color & Profile = None
Door Screen Type = No Screen
Door Bore = Double Bore
Inactive Door Bore = Double Bore
Bore Backset = 2 3/8"
Bore Diameter = 2 1/8"
Lockset Bore Position = 44
Dead Bolt Bore Position = 5 1/2"
Hinge Prep = 3-Hinge Prep
Hinge Size = 4 x 4-1/4"
Hinge Type = Ball Bearing w/Safety Stud
Hinge Radius = 5/8" Radius / Square
Hinge Finish = Satin Nickel
First.Hinge Position = 6 3/4"
Second Hinge Position = 36"
Third Hinge Position = 65 1/4"
Astragal = HD White Aluminum
Astragal Location = Inactive Door
Security Flange = No
Flush Bolts = Flush Bolt Top and Bottom
Flush Bolt Finish = Satin Nickel
Jamb Width = 4 9/16"
Jamb Finish Type = None
Jamb Specie = Finger -Jointed Primed
Weather -Strip Type = Compression Bronze
Sill / Threshold Type = All Aluminum
Sill Width = 4 9/16"
Sill Finish = Aluminum
Room Location = no
Is This a Remake = No
Specific Information =
Sup
UFA",l �-0)1
www.HomeDepot.com Page 8 of 14 Printed By: DAVID
Date Printed: 8/30/2016 10:45 AI' I
Ju ui.�Ul d+ ur ndung = ur rzu/-au
Florida Approval Number=16674.4
Door U-Factor = 0
Door Solar Heat Gain Coefficient = 0
SKU=115728
Vendor Name = S/O JELD-WEN DOOR SYSTMS
Vendor Number = 60075920.
Manufacturer=JELD-WEN, Kissimmee (FL)
Customer Service=1.800.246.9131
Catalog Version Date = 08/10/2016
"All prices are subject to change
"Customer is responsible for verifying product selections. The Home
"All graphics viewed from the exterior
Pre -Tax Price: $5,423.74
not accept returns for the above products
www.HomeDepot.com Page 9 of 14 Printed By: DAVID
Date Printed: 8/30/2016 10:45 AM