n - wrightsoft, Project Summary Enure House QUICK CALCS, INC. �\ 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM For: RUSKOSKY RESIDENCE LOGGERHEAD PLACE LOT #381, ST. LUCIE COUNTY, FL Notes: Job: Date: Jul 20, 2016 By: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 11525 Btuh Ducts 3486 Btuh Central vent (25 cfm) 759 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 15770 Btuh Infiltration Method Simplified Construction quality Average 0 Fireplaces Heating Cooling Area (ftz) 1024 1024 Volume (ft') 9216 9216 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 69 35 Heating Equipment Summary ` Make Trade Model AHRI ref Efficiency 100 EFF Heating input 5.1 kW Heating output 17448 Btuh Temperature rise 50 OF Actual air flow 318 cfm Air flow factor 0.021 cfm/Btuh Static pressure, 0.50 in H2O Space thermostat Sensible Cooling Equipment Load Sizing Structure 10521 Btuh Ducts 4673 Btuh Central vent (25 cfm) 407 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 14820 Btuh Latent Cooling Equipment Load Sizing Structure 2076 Btuh Ducts 1475 Btuh Central vent (25 cfm) 1031 Btuh Equipment latent load 4581 Btuh Equipment total load 19401 Btuh Req. total capacity at 0.70 SHR 1.8 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR40251_1 Coil TMM5AOB24M21SAA AHRI ref 7932227 Efficiency 13.0 EER, 16 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.053 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio Calculations approved by ACCA to meet all requirements of 1 al t�1 i:.: �• �`R��e �. WCI htsoft° 2016-Jul-2011:24:53 �� 9 Right -Suite® Universal 2017 17.0.03 RSU08101 Page 1 ..rs\Quick Calcs\Documents\RUSKOSKY RESIDENCE.rup Calc = MJ8 Front Door faces: W a +�- wrightsoft° Right-JO Worksheet Job: Entire House . Date: Jul 20, 2016 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fare 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House LIVING 2 Exposed wall 140.0 ft 54.0 ft 3 Room height 9.0 ft d 9.0 It heat/cool 4 5 Room dimensions Room area 1024.0 ft' 1.0 x 343.0 It 343.0 ft' Ty Construction U-value Or HTM Area ffl Load Area (ftj Load number (Btuh/ft� "F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 2 glazing, clr low-e 0.143 0.650 n n 4.00 18.20 2.55 14.57 441 9 405 0 1622 164 1031 131 117 0 105 0 420 0 267 0 2 glazing, cirlow-e 0.650 n 18.20 14.57 12 0 218 175 12 0 218 175 2 glazing, clr low-e 0.650 n 18.20 14.57 15 0 273 219 0 0 0 0 W 11 13A-40cs 0.143 a 4.00 2.55 189 183 733 466 0 0 0 0 �G 2 qlazing, cir low-e 0.650 a 18.20 31.85 6 0 109 191 0 0 0 0 13A-4ocs 0.143 s 4.00 2.55 441 398 1594 1013 180 162 609 387 2 glazing, clr low-e 0.650 s 18.20 14.57 12 12 218 175 12 12. 218 175 2 glazing, clr low-e 0.650 s 18.20 14.57 16 16 291 233 16 16 291 233 2 glazing, clrlow-e 0.650 s 18.20 14.57 15 15 273 219 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.55 189 133 533 339 189 133 533 339 G 2 glazing, clr low-e 2 glazinq, clr low-e 16B-30ad 0.650 0.650 0.032 w w - 18.20 18.20 0.90 14.57 20.32 1.68 8 48 1024 8 32 1024 146 _ 874 918 117 975 1720 8 48 343 8 32 343 146 874 307 117 975 576 C F 20P-19t 0.050 - 1.40 0.63 1024 1024 1434 640 343 343 480 214 6 c) AED excursion 605 730 Envelope loss/gain 9398 8248 4096 4188 12 a) Infiltration 2127 582 620 225 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13) 11525 10521 4917 4413 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 11525 10521 4917 4413 15 Ductloads 30% 44% 3486 4673 30% 44% 1487 1960 Total room load 15011 15193 6404 6373 Air required (cfm) 318 800 135 336 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- Right -Suite® Universal 2017 17.0.03 RSU08101 2016-Jul-20 11::23:00 ...rs%Quick CalcslDocuments%RUSKOSKY RESIDENCE.rup Cale = MJ8 Front Door faces: W -�- wrightsoft° Right-M Worksheet Job: Entire House Date: Jul 20, 2016 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name KITCHEN LAUND 2 Exposed wall 12.0 It 6.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat1cool 4 Room dimensions 1.0 x 156.0 ft 6.0 x 7.0 ft 5 Room area 156.0 ft2 42.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft7-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00' 2.55 108 99 396 252 64 54 216 137 2 glazing, cir low-e 0.650 n 18.20 14.57 9 0 -164 131 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.57 0 .0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.57 0 0 0 0 0 0 0 0 VN �G 11 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 a 18.20 31.85 0 0 0- 0 0 0 0 0 13A-4ocs 0.143 s 4:00 2 55 0 0 0 0 0 0 0 0 2 glazing, cirlow-e 0.650 s 18.20 14.57 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 16.20 14.67 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.57 0- 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 14.57 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 20.32 0_ 0 0_ 0 0 0 0 0 C 168-30ad 0.032 - 0.90 1.68 156 156, 140 262 42 42 38 71 F 20PASt 0.050 - 1.40 0.63 156 156 218 98 42 42 59 26 6 c) AED excursion -39 -6 Envelope loss/gain 918 704 313 229 12 a) Infiltration 182 50 91 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13) 1101 1754 404 254 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1101 1754 404 254 15 Duct loads 30% 44% 333 779 30% 44% 122 113 Total room load 1434 2533 526 366 Air required (cfm) 30 133 11 19 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fp- wrightsoft' Right -Suite® Universal 2017 17.0.03 RSU08101 2016-Jul-20 1 :223 00 ...rs\Quick Calcs\Documents\RUSKOSKY RESIDENCE.rup Caic = MJ8 Front Door faces: W Page 2 -- wrightsoft®, Right-JO Worksheet Job: Entire House Date: Jul 20, 2016 QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM 2 Exposed wall 6.0 ft 14.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 6.0 x 10.0 ft 14.0 x 10.0 ft 5 Room area 60.0 ft2 140.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ftj Load number (Btuh/ft;°F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 �-G 2 glazing, clr l(yw-e 0.650 n 18.20 14.57 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.57 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.57 0 0 0 0 0 0 0 0 W 11 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 �-G 2 glazing, clr low-e 0.650 a 18.20 31.85 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.55 54 54 216 137 126 111 444 283 2 glazing, clr low-e 0.650 s 18.20 14.57 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.57 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.57 0 0 0 0 15 15 273 219 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1W 2 glazing, cir low-e 0.650 w 18.20 14.57 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 20.32 0 0 0 0 0 0 0 0 C 168-30ad 0.032 - 0.90 1.68 60 60 54 101 140 140 125 235 F 20P-19t 0.050 - 1.40 0.63 60 60 84 38 140 140 196 88 6 c) AED excursion -7 -24 Envelope loss/gain 354 269 1039 800 12 a) infiltration 91 25 213 58 b) Room ventilation 0 0 0 0 13 1ntemai gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 1 445 294 12521 1088 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 445 294 1252 1088 15 Duct loads 30% 44% 135 131 30% 44°/6 379 483 Total room load 580 425 1 1630 1571 Air required (cfm) 12 22 34 83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoTt' AaZRight-Suite® Universal 2017 17.0.03 RSU08101 201&Jul 20 11P'age 3 ... rs\Quick Calcs\Documents\RUSKOSKY RESIDENCE.rup Calc = MJ8 Front Door faces: W - wrightsoft° Right-M Worksheet Job: Entire House Date: Jul 20, 2016 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name CLOST WIC 2 Exposed wall 13.0 ft 6.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 8.0 x 5.0 ft 9.0 x 5.0 ft 5 Room area 40.0 ftz 45.0 ft' Ty Constriction U-value Or HTM Area (ft5 Load Area (ft2) Load number (BtutVftZ °F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VVJJJJ 13A-40cs 0.143 n 4.00 * 2.55 0 0 0 0 0 0 0 0 F- -G 2 glazing, cir low-e 0.650 n 18.20 14.57 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.57 0 0 0 0 0 0 . 0 0 L��G 2glazing, cir low-e 0.650 n 18.20 '14.57 0 0 0 0 0 0 0 0 VG �C 11 13A-4ocs 0.143 a 4.00 2.55 45 45 180 115 45 45 180 115 2 glazing, cir low-e 0.650 a 18.20 31.85 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.55 72 72 288 183 9 9 36 23 2 glazing, cir low-e 0.650 s 18.20 14.57 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.26 14.57 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.57 0 0 0 0 .0 _ 0. 0 0 IW 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 14.57 0 0 0 0 0 0 0 0 �--G 2 glazing, cir low-e 0.650 w 18.20 20.32 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 - 0.90 1.68 40 40 _ 36 67 45 45 40 76 F 20P-19t 0.050 - 1.40 0.63 40 40 56 25 45 45 63 28 6 c) AED excursion -10 -6 Envelope loss/gain 560 380 320 235 12 a) Infiltration 198 54 91 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 758 434 411 260 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 758 434 411 260 15 Duct loads 30% 44% 229 193 30% 44% 1241 116 Ij Total room load 987 6271 T535 376 Air required (cfm) 21 33 11 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 411- wrightsoftm 2016-Jul-2011:25:59 Right -Suite® Universal 201717.0.03 RSU08101 Page 4 ...rs%Quick Calcs\DocumentslRUSKOSKY RESIDENCE.rup Calc = MJ8 Front Door faces: W - wrightsoft® Right-JO Worksheet Job: Entire House Date: Jul 20, 2016 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name CLOST WIC 2 Exposed wall 13.0 ft 6.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 8.0 x 5.0 ft 9.0 x 5.0 ft 5 Room area 40.0 ft2 45.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area (ftj Load number (Btuh/W °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool . Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A40cs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 F-G 2 glazing, clr low-e 0.650 n 18.20 14.57 ' 0 0 0 0 0 0 0 0 2 glazing, clrlow-e 0.650 n 18.20 14.57 0 0 0 .0 0 0 0 0 2 glazing, clr low a 0.650 .n 18.20 14.57 0 0_ 0 0 0 0 0 0 T 11 13A-4ocs 0.143 a 4.00 2.55 45 45 180 115 45 45 180 115 �G 2 glazinq, clr low-e 0.650 e. 18.20 31.85 0 0 0 0 0 0 0 0 V)/ 1- 4ocs 0.143 s 4.00 2.55 72 72 288 183 9 9, 36 23 2 glazing, clr low-e 0.650 s 18.20 14.57 0 0 0 0 0 6 0 0 2 glazing, clr low-e 0.650 s 18.20. 14.57 0 0 0 0 0 0 0 0 II---GGGI 2 glazing, clr low-e 0.650 s 18.20 14.57 0 0 0 O 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 LlF--ci 2 glazing, clr low-e 0.650 w 18.20 14.57 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 20.32 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 0.90 1.68 40 40 36 67 45 45 40 76 F 20P-19t 0.050 - 1.40 0.63 40 40 56 25 45 45 63 26 6 c) AED excursion -10 -6 Envelope loss/gain 560 380 320 235 12 a) Infiltration 198 54 91 25 b) Room ventilation 0 0 0 0 13 1ntemal gains: Occupants 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 758 434 411 260 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 758 434 411 260 15 Duct loads 30% 44% 229 193 300/0 44% 124 116 Total room load 987 6277- 535 376 Air required (cfm) 21 33 11 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A - wrightsoft- 2016-Jul-20 11:27:40 Right -Suite® Universal 2017 17.0.03 RSU08101 Page 4 ...rs%Quick Calcs\Documents%RUSKOSKY RESIDENCE.rup Cale = MJ8 Front Door faces: W Duct System Summary Job: -�+ Wrightsoft° Date: Jul 20, 2016 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM For: RUSKOSKY RESIDENCE LOGGERHEAD PLACE LOT #381, ST. LUCIE COUNTY, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250/1 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate0.355 in/100ft 0.355 in/100ft Actual air flow 318 cfm 800 cfm Total effective length (TEL) 141 ft Name Design (13tuh) Htg (Cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 425 12 22 0.364 4.0 Ox 0 VIFx 22.2 115.0 st2 BEDROOM c 1571 34 83 0.369 7.0 Ox 0 VIFx 20.4 115.0 st1 CLOST c 627 21 33 0.368 4.0 Ox 0 VIFx 21.0 115.0 st1 KITCHEN c 2533 30 133 0.380 7.0 Ox 0 VIFx 16.6 115.0 st2 LAUND c 366 11 19 0 0 Ox 0 VIFx 0 0 LIVING c 2124 45 112 0.355 7.0 Ox 0 VIFx 25.8 115.0 st2 LIVING -A c 2124 45 112 0.358 7.0 Ox 0 VIFx 24.7 115.0 st2 LIVING-B c 2124 45 112 0.375 7.0 Ox 0 VIFx 18.4 115.0 st2 M BEDROOM C 1793 31 94 0.381 7.0 Ox 0 VIFx 16.2 115.0 st1 M. BATH C 1129 31 59 0.381 5.0 Ox 0 VIFx 16.2 115.0 st1 wic c 376 11 20 0.379 4.0 Ox 0 VIFx 16.8 115.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 128 289 0.368 829 8.0 0 x 0 VinlFlx st2 Peak AVF 178 491 0.355 901 10.0 0 x 0 VinlFlx wri htsoft° 2016-Jul-2011:23:01 I1 9 Right -Suite® Universal 2017 17.0.03 RSUC8101 Page 1 ...rs\Quick Calcs\Documents\RUSKOSKY RESIDENCE.rup Calc = MJ8 Front Door faces: W Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 318 800 0 0 0 0 Ox 0 VIFx wri htsoft® 2016-Jul-2011:23:01 9 Right-Sufte® Universal 2017 17.0.03 RSU08101 Page 2 ACC** ...rs\Quick CalcsMocuments%RUSKOSKY RESIDEN CE.rup Calc = MJ8 Front Door faces: W