Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProject Informationn
- wrightsoft, Project Summary
Enure House
QUICK CALCS, INC.
�\ 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM
For: RUSKOSKY RESIDENCE
LOGGERHEAD PLACE LOT #381, ST. LUCIE COUNTY, FL
Notes:
Job:
Date: Jul 20, 2016
By:
Weather:
Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Outside db
90
OF
Inside db 70 OF
Inside db
75
OF
Design TD 28 OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating Summary
Structure
11525
Btuh
Ducts
3486
Btuh
Central vent (25 cfm)
759
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
15770
Btuh
Infiltration
Method
Simplified
Construction quality
Average
0
Fireplaces
Heating
Cooling
Area (ftz)
1024
1024
Volume (ft')
9216
9216
Air changes/hour
0.45
0.23
Equiv. AVF (cfm)
69
35
Heating Equipment
Summary
` Make
Trade
Model
AHRI ref
Efficiency
100 EFF
Heating input
5.1
kW
Heating output
17448
Btuh
Temperature rise
50
OF
Actual air flow
318
cfm
Air flow factor
0.021
cfm/Btuh
Static pressure,
0.50
in H2O
Space thermostat
Sensible Cooling Equipment Load Sizing
Structure 10521 Btuh
Ducts 4673 Btuh
Central vent (25 cfm) 407 Btuh
Blower 0 Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 14820 Btuh
Latent Cooling Equipment Load Sizing
Structure
2076
Btuh
Ducts
1475
Btuh
Central vent (25 cfm)
1031
Btuh
Equipment latent load
4581
Btuh
Equipment total load 19401 Btuh
Req. total capacity at 0.70 SHR 1.8 ton
Cooling Equipment Summary
Make Trane
Trade TRANE
Cond 4TTR40251_1
Coil TMM5AOB24M21SAA
AHRI ref 7932227
Efficiency
13.0 EER, 16 SEER
Sensible cooling
16800
Btuh
Latent cooling
7200
Btuh
Total cooling
24000
Btuh
Actual air flow
800
cfm
Air flow factor
0.053
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
Calculations approved by ACCA to meet all requirements of
1
al t�1 i:.: �• �`R��e �.
WCI htsoft° 2016-Jul-2011:24:53
�� 9 Right -Suite® Universal 2017 17.0.03 RSU08101 Page 1
..rs\Quick Calcs\Documents\RUSKOSKY RESIDENCE.rup Calc = MJ8 Front Door faces: W
a
+�- wrightsoft° Right-JO Worksheet Job:
Entire House . Date: Jul 20, 2016
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fare 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
Entire House
LIVING
2
Exposed wall
140.0 ft
54.0 ft
3
Room height
9.0 ft d
9.0 It heat/cool
4
5
Room dimensions
Room area
1024.0 ft'
1.0 x 343.0 It
343.0 ft'
Ty
Construction
U-value
Or
HTM
Area ffl
Load
Area (ftj
Load
number
(Btuh/ft� "F)
(Btuh/ft�
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A4ocs
2 glazing, clr low-e
0.143
0.650
n
n
4.00
18.20
2.55
14.57
441
9
405
0
1622
164
1031
131
117
0
105
0
420
0
267
0
2 glazing, cirlow-e
0.650
n
18.20
14.57
12
0
218
175
12
0
218
175
2 glazing, clr low-e
0.650
n
18.20
14.57
15
0
273
219
0
0
0
0
W
11
13A-40cs
0.143
a
4.00
2.55
189
183
733
466
0
0
0
0
�G
2 qlazing, cir low-e
0.650
a
18.20
31.85
6
0
109
191
0
0
0
0
13A-4ocs
0.143
s
4.00
2.55
441
398
1594
1013
180
162
609
387
2 glazing, clr low-e
0.650
s
18.20
14.57
12
12
218
175
12
12.
218
175
2 glazing, clr low-e
0.650
s
18.20
14.57
16
16
291
233
16
16
291
233
2 glazing, clrlow-e
0.650
s
18.20
14.57
15
15
273
219
0
0
0
0
W
13A-4ocs
0.143
w
4.00
2.55
189
133
533
339
189
133
533
339
G
2 glazing, clr low-e
2 glazinq, clr low-e
16B-30ad
0.650
0.650
0.032
w
w
-
18.20
18.20
0.90
14.57
20.32
1.68
8
48
1024
8
32
1024
146
_ 874
918
117
975
1720
8
48
343
8
32
343
146
874
307
117
975
576
C
F
20P-19t
0.050
-
1.40
0.63
1024
1024
1434
640
343
343
480
214
6
c) AED excursion
605
730
Envelope loss/gain
9398
8248
4096
4188
12
a) Infiltration
2127
582
620
225
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
3
690
0
0
Appliances/other
1000
0
Subtotal (lines 6 to 13)
11525
10521
4917
4413
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
11525
10521
4917
4413
15
Ductloads
30%
44%
3486
4673
30%
44%
1487
1960
Total room load
15011
15193
6404
6373
Air required (cfm)
318
800
135
336
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft- Right -Suite® Universal 2017 17.0.03 RSU08101 2016-Jul-20 11::23:00
...rs%Quick CalcslDocuments%RUSKOSKY RESIDENCE.rup Cale = MJ8 Front Door faces: W
-�- wrightsoft° Right-M Worksheet Job:
Entire House Date: Jul 20, 2016
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM
1
Room name
KITCHEN
LAUND
2
Exposed wall
12.0 It
6.0 ft
3
Room height
9.0 ft heat/cool
9.0 ft heat1cool
4
Room dimensions
1.0 x 156.0 ft
6.0 x 7.0 ft
5
Room area
156.0 ft2
42.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/ft7-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A-4ocs
0.143
n
4.00'
2.55
108
99
396
252
64
54
216
137
2 glazing, cir low-e
0.650
n
18.20
14.57
9
0
-164
131
0
0
0
0
2 glazing, cir low-e
0.650
n
18.20
14.57
0
.0
0
0
0
0
0
0
2 glazing, cir low-e
0.650
n
18.20
14.57
0
0
0
0
0
0
0
0
VN
�G
11
13A-4ocs
0.143
a
4.00
2.55
0
0
0
0
0
0
0
0
2 glazing, cir low-e
0.650
a
18.20
31.85
0
0
0-
0
0
0
0
0
13A-4ocs
0.143
s
4:00
2 55
0
0
0
0
0
0
0
0
2 glazing, cirlow-e
0.650
s
18.20
14.57
0
0
0
0
0
0
0
0
2 glazing, clr low-e
0.650
s
16.20
14.67
0
0
0
0
0
0
0
0
2 glazing, cir low-e
0.650
s
18.20
14.57
0-
0
0
0
0
0
0
0
13A-4ocs
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
2 glazing, clr low-e
0.650
w
18.20
14.57
0
0
0
0
0
0
0
0
2 glazing, cir low-e
0.650
w
18.20
20.32
0_
0
0_
0
0
0
0
0
C
168-30ad
0.032
-
0.90
1.68
156
156,
140
262
42
42
38
71
F
20PASt
0.050
-
1.40
0.63
156
156
218
98
42
42
59
26
6
c) AED excursion
-39
-6
Envelope loss/gain
918
704
313
229
12
a) Infiltration
182
50
91
25
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
1000
0
Subtotal (lines 6 to 13)
1101
1754
404
254
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
1101
1754
404
254
15
Duct loads
30%
44%
333
779
30%
44%
122
113
Total room load
1434
2533
526
366
Air required (cfm)
30
133
11
19
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-Fp- wrightsoft' Right -Suite® Universal 2017 17.0.03 RSU08101 2016-Jul-20 1 :223 00
...rs\Quick Calcs\Documents\RUSKOSKY RESIDENCE.rup Caic = MJ8 Front Door faces: W Page 2
-- wrightsoft®, Right-JO Worksheet Job:
Entire House Date: Jul 20, 2016
QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
BATH
BEDROOM
2
Exposed wall
6.0 ft
14.0 ft
3
Room height
9.0 ft heat/cool
9.0 ft heat/cool
4
Room dimensions
6.0 x 10.0 ft
14.0 x 10.0 ft
5
Room area
60.0 ft2
140.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft�
Load
Area (ftj
Load
number
(Btuh/ft;°F)
(Btuh/ftj
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A-4ocs
0.143
n
4.00
2.55
0
0
0
0
0
0
0
0
�-G
2 glazing, clr l(yw-e
0.650
n
18.20
14.57
0
0
0
0
0
0
0
0
2 glazing, cir low-e
0.650
n
18.20
14.57
0
0
0
0
0
0
0
0
2 glazing, clr low-e
0.650
n
18.20
14.57
0
0
0
0
0
0
0
0
W
11
13A-4ocs
0.143
a
4.00
2.55
0
0
0
0
0
0
0
0
�-G
2 glazing, clr low-e
0.650
a
18.20
31.85
0
0
0
0
0
0
0
0
13A-4ocs
0.143
s
4.00
2.55
54
54
216
137
126
111
444
283
2 glazing, clr low-e
0.650
s
18.20
14.57
0
0
0
0
0
0
0
0
2 glazing, cir low-e
0.650
s
18.20
14.57
0
0
0
0
0
0
0
0
2 glazing, clr low-e
0.650
s
18.20
14.57
0
0
0
0
15
15
273
219
13A-4ocs
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
1W
2 glazing, cir low-e
0.650
w
18.20
14.57
0
0
0
0
0
0
0
0
2 glazing, cir low-e
0.650
w
18.20
20.32
0
0
0
0
0
0
0
0
C
168-30ad
0.032
-
0.90
1.68
60
60
54
101
140
140
125
235
F
20P-19t
0.050
-
1.40
0.63
60
60
84
38
140
140
196
88
6
c) AED excursion
-7
-24
Envelope loss/gain
354
269
1039
800
12
a) infiltration
91
25
213
58
b) Room ventilation
0
0
0
0
13
1ntemai gains: Occupants @ 230
0
0
1
230
Appliances/other
0
0
Subtotal (lines 6 to 13)
1
445
294
12521
1088
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
445
294
1252
1088
15
Duct loads
30%
44%
135
131
30%
44°/6
379
483
Total room load
580
425
1
1630
1571
Air required (cfm)
12
22
34
83
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoTt' AaZRight-Suite® Universal 2017 17.0.03 RSU08101 201&Jul 20 11P'age 3
... rs\Quick Calcs\Documents\RUSKOSKY RESIDENCE.rup Calc = MJ8 Front Door faces: W
- wrightsoft° Right-M Worksheet Job:
Entire House Date: Jul 20, 2016
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM
1
Room name
CLOST
WIC
2
Exposed wall
13.0 ft
6.0 ft
3
Room height
9.0 ft heat/cool
9.0 ft heat/cool
4
Room dimensions
8.0 x 5.0 ft
9.0 x 5.0 ft
5
Room area
40.0 ftz
45.0 ft'
Ty
Constriction
U-value
Or
HTM
Area (ft5
Load
Area (ft2)
Load
number
(BtutVftZ °F)
(Btuh/ft5
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
VVJJJJ
13A-40cs
0.143
n
4.00
* 2.55
0
0
0
0
0
0
0
0
F- -G
2 glazing, cir low-e
0.650
n
18.20
14.57
0
0
0
0
0
0
0
0
2 glazing, cir low-e
0.650
n
18.20
14.57
0
0
0
0
0
0
. 0
0
L��G
2glazing, cir low-e
0.650
n
18.20
'14.57
0
0
0
0
0
0
0
0
VG
�C
11
13A-4ocs
0.143
a
4.00
2.55
45
45
180
115
45
45
180
115
2 glazing, cir low-e
0.650
a
18.20
31.85
0
0
0
0
0
0
0
0
13A-4ocs
0.143
s
4.00
2.55
72
72
288
183
9
9
36
23
2 glazing, cir low-e
0.650
s
18.20
14.57
0
0
0
0
0
0
0
0
2 glazing, clr low-e
0.650
s
18.26
14.57
0
0
0
0
0
0
0
0
2 glazing, clr low-e
0.650
s
18.20
14.57
0
0
0
0
.0
_ 0.
0
0
IW
13A-4ocs
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
2 glazing, clr low-e
0.650
w
18.20
14.57
0
0
0
0
0
0
0
0
�--G
2 glazing, cir low-e
0.650
w
18.20
20.32
0
0
0
0
0
0
0
0
C
1613-30ad
0.032
-
0.90
1.68
40
40
_ 36
67
45
45
40
76
F
20P-19t
0.050
-
1.40
0.63
40
40
56
25
45
45
63
28
6
c) AED excursion
-10
-6
Envelope loss/gain
560
380
320
235
12
a) Infiltration
198
54
91
25
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
758
434
411
260
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
758
434
411
260
15
Duct loads
30%
44%
229
193
30%
44%
1241
116
Ij
Total room load
987
6271
T535
376
Air required (cfm)
21
33
11
20
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
411- wrightsoftm 2016-Jul-2011:25:59
Right -Suite® Universal 201717.0.03 RSU08101 Page 4
...rs%Quick Calcs\DocumentslRUSKOSKY RESIDENCE.rup Calc = MJ8 Front Door faces: W
- wrightsoft® Right-JO Worksheet Job:
Entire House Date: Jul 20, 2016
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
CLOST
WIC
2
Exposed wall
13.0 ft
6.0 ft
3
Room height
9.0 ft heat/cool
9.0 ft heat/cool
4
Room dimensions
8.0 x 5.0 ft
9.0 x 5.0 ft
5
Room area
40.0 ft2
45.0 ftz
Ty
Construction
U-value
Or
HTM
Area (ft�
Load
Area (ftj
Load
number
(Btuh/W °F)
(Btuh/ft�
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool .
Gross
N/PIS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A40cs
0.143
n
4.00
2.55
0
0
0
0
0
0
0
0
F-G
2 glazing, clr low-e
0.650
n
18.20
14.57
' 0
0
0
0
0
0
0
0
2 glazing, clrlow-e
0.650
n
18.20
14.57
0
0
0
.0
0
0
0
0
2 glazing, clr low a
0.650
.n
18.20
14.57
0
0_
0
0
0
0
0
0
T
11
13A-4ocs
0.143
a
4.00
2.55
45
45
180
115
45
45
180
115
�G
2 glazinq, clr low-e
0.650
e.
18.20
31.85
0
0
0
0
0
0
0
0
V)/
1- 4ocs
0.143
s
4.00
2.55
72
72
288
183
9
9,
36
23
2 glazing, clr low-e
0.650
s
18.20
14.57
0
0
0
0
0
6
0
0
2 glazing, clr low-e
0.650
s
18.20.
14.57
0
0
0
0
0
0
0
0
II---GGGI
2 glazing, clr low-e
0.650
s
18.20
14.57
0
0
0
O
0
0
0
0
W
13A-4ocs
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
LlF--ci
2 glazing, clr low-e
0.650
w
18.20
14.57
0
0
0
0
0
0
0
0
2 glazing, clr low-e
0.650
w
18.20
20.32
0
0
0
0
0
0
0
0
C
16B-30ad
0.032
-
0.90
1.68
40
40
36
67
45
45
40
76
F
20P-19t
0.050
-
1.40
0.63
40
40
56
25
45
45
63
26
6
c) AED excursion
-10
-6
Envelope loss/gain
560
380
320
235
12
a) Infiltration
198
54
91
25
b) Room ventilation
0
0
0
0
13
1ntemal gains: Occupants 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
758
434
411
260
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
758
434
411
260
15
Duct loads
30%
44%
229
193
300/0
44%
124
116
Total room load
987
6277-
535
376
Air required (cfm)
21
33
11
20
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
A - wrightsoft- 2016-Jul-20 11:27:40
Right -Suite® Universal 2017 17.0.03 RSU08101 Page 4
...rs%Quick Calcs\Documents%RUSKOSKY RESIDENCE.rup Cale = MJ8 Front Door faces: W
Duct System Summary Job:
-�+ Wrightsoft° Date: Jul 20, 2016
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM
For: RUSKOSKY RESIDENCE
LOGGERHEAD PLACE LOT #381, ST. LUCIE COUNTY, FL
Heating
Cooling
External static pressure
0.50
in H2O
0.50 in H2O
Pressure losses
0
in H2O
0 in H2O
Available static pressure
0.50
in H2O
0.50 in H2O
Supply / return available pressure
0.250/1 0.250
in H2O
0.250 / 0.250 in H2O
Lowest friction rate0.355
in/100ft
0.355 in/100ft
Actual air flow
318
cfm
800 cfm
Total effective length (TEL)
141 ft
Name
Design
(13tuh)
Htg
(Cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
c 425
12
22
0.364
4.0
Ox 0
VIFx
22.2
115.0
st2
BEDROOM
c 1571
34
83
0.369
7.0
Ox 0
VIFx
20.4
115.0
st1
CLOST
c 627
21
33
0.368
4.0
Ox 0
VIFx
21.0
115.0
st1
KITCHEN
c 2533
30
133
0.380
7.0
Ox 0
VIFx
16.6
115.0
st2
LAUND
c 366
11
19
0
0
Ox 0
VIFx
0
0
LIVING
c 2124
45
112
0.355
7.0
Ox 0
VIFx
25.8
115.0
st2
LIVING -A
c 2124
45
112
0.358
7.0
Ox 0
VIFx
24.7
115.0
st2
LIVING-B
c 2124
45
112
0.375
7.0
Ox 0
VIFx
18.4
115.0
st2
M BEDROOM
C 1793
31
94
0.381
7.0
Ox 0
VIFx
16.2
115.0
st1
M. BATH
C 1129
31
59
0.381
5.0
Ox 0
VIFx
16.2
115.0
st1
wic
c 376
11
20
0.379
4.0
Ox 0
VIFx
16.8
115.0
st1
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st1
Peak AVF
128
289
0.368
829
8.0
0 x 0
VinlFlx
st2
Peak AVF
178
491
0.355
901
10.0
0 x 0
VinlFlx
wri htsoft° 2016-Jul-2011:23:01
I1 9 Right -Suite® Universal 2017 17.0.03 RSUC8101 Page 1
...rs\Quick Calcs\Documents\RUSKOSKY RESIDENCE.rup Calc = MJ8 Front Door faces: W
Return Branch Detail Table
Name
Grill
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox 0
318
800
0
0
0
0
Ox 0
VIFx
wri htsoft® 2016-Jul-2011:23:01
9 Right-Sufte® Universal 2017 17.0.03 RSU08101 Page 2
ACC** ...rs\Quick CalcsMocuments%RUSKOSKY RESIDEN CE.rup Calc = MJ8 Front Door faces: W