GENERAL NOTES:
1. Construction shall follow Florida Building Code as adopted by the
County or City in which the building is to be constructed with all
applicable amendments.
2. The Contractor , Subcontractor , Supplier , Etc shall verify all
dimensions , conditions at the jobsite plans and Specifications.
3. All written dimensions on these drawings take precedence over
scaled dimensions
4. Structural features not detailed on these plans will be addressed
by the engineer as construction progresses.
STRUCTURAL NOTES
1, Design Loads:
Roof (DL+LL)= 50 PSF
Wind Velocity- 163 MPH Supporting Structure (Fastest Mile)
2. Soil Bearing Capacity 2500 PSF with Compaction Test Result
of more than 95%.
2a.Soi1 density shall be in compliance with R401 of 2017 Florida
Residential Building Code
3. All Structure Concrete and Grout shall have a minimum compressive
Strength of 3000 PSI at 28 days .
4. Slab/Footings to be concrete with minimum compressive Strength of
2500 PSI at 28 days . See plans for size and steel requirements.
5. Minimum Concrete protection for reinforcement Bars:
Beams: 1 1/2 " Footings: 3"
6. Lap all reinforcing Steel a minimum of 48 bar diameters.
7. All Standard Lumber shall be SPF , or stud grade with minimum
Fb=1200 PSI or better.
8. All lumber in contact with concrete or masonry shall be Pressure
Treated.
9, Splitting or cracking of structural components due to installation of
hardware is not permitted.
10. Unless
conformotherwise
to the manufacturersinstallation
ctions specified
hardware shall
standards.
11. Bearings points of °-h--eaders, girders and beams shall have vertical
supports sufficient to support loads and shall be properly
anchored for uplift as will be noted.
12. Roof Sheathing to be nailed with 8d Galy. nails or equal, 6" O.C.
13. Unless otherwise noted for exterior walls, exterior plywood
walls is to be nailed with 10d nails or
sheathing and interior dry
8 O.C. Filled Drywall screwsr 1.5" long
better , 6" O.C. edges and
and .131" in diameter.
14. Ftoprchords or installation
alongblock
thewith
edge2of plywood directly below
the vent.
15. For Frame Segment to masonry segment connections use PT
vertical secured to masonry with 3/16" dia. lag screws 3/4"
embedment to 3000# concrete min 18" O.C.
16. WALLS: The double top plate (butt splices) shall resist 4000lb/splice
-All wall top plates shall be lapped a min. of 24" C splices w/
7-16d nails min. lap center 1/3 of wall shall be 4' w/9-16d
nails.
17. At Gable, provide 2x4 full blocking to the trusses for the first two
truss spacing, spaced at 4' O.C. nailing shall be 4" O.C. at first
truss.
18. Apply Plywood roof sheathing face grain perpendicular to supports.
19. All roof covering shall be applied per manufacturers
recommendations or per FBC and local codes whichever is more
strenuous.
O WINPOW ANP
POOF? 5CH�_-bUI,� /
MOPUCT APMOVAL5
WINDOW Oft
pp0bUCr
n�51GN
IMPACT
IN51'ALLA110N &
AT1ACNM�N1
ACC�P1'ANCP
NUM13�{?
12 TT,`
OFF-NING PPOPUCT
MOn�� NUMP�F,
b0012 MPG' I',
PI?�SSU
M, 515ITAN�f
MF-TH0n
Ib
Defer to 5peclficatlons
F[-# I27659
12/ 30/ 2020
poll -UP
MOFI- 11004
JANU5 INTL.. COPP,
r 46.-5�}
Yes
& IZrawinq in product
Approval
GAP.A6� n001?
16W X ION
55, "55
Yes
Refer to 5pedficatio119
& Prawlncq in Product
rL,# 22513,6
6/ -50/ 2021
5ide F_xt, Poor
Masonite International
Approval
i�001?
12efer to 5pecificat10115
& I2rawinq in Product
PL.# 1_}911.5
8/ O3/ 2021
WINDOW
5N 70 5eric5
5ilver Line PUcq Products
-60
Yes
Approval
may size 3604
N/A
Refer to Speclflcatlons
& Prawincq in Product
NOA 16-1116,09
1 / 25/ 2022
Door
Underlaument
Tarco 5pecialty Prod,
N/A
Approval
30# Pelt
I:efer to 5peclflcatlons
Defer to Attached
19,efer to Attache
& 12rawlnq In Product
j7ocuments
Poc uments
A
�A55 1000 26 GA
bM CA
17YNAMIC M�iAL, ��C
-176 P5P
N/ A
Approval
l:OOf
GAL12L
I" NAItSTIJP 1 Wibr
JURISDICTION: ST. LUCIE COUNTY
CODE: 2017 FLORIDA BUIILDING CODE
BUILDING CLASSIFICATION: CATEGORY II
MINIMUM SOIL BEARING PRESSURE: 2500 psf.
LATERAL LOAD OF TRUSS ANCHORS CONSIDERED: YES
SHEAR WALL CONSIDERED: YES
CONTINUOUS LOAD PATH PROVIDED: YES
WIND SPEED (3 SECOND GUST): 160 MPH
IMPORTANCE FACTOR: 1_0
EXPOSURE: CATEGORY C
MEAN ROOF HEIGHT: 14'-0"
BUILDING DESIGNED AS: ENCLOSED
INTERNAL PRESSURE COEFFICIENT + -0.18
EXTERNAL PRESSURECOEFFICIENTS FOLLOWS:
-
VERTICAL GCpf: + 1.07
HORIZONTAL GCpf: -1.4
ROOF OVERHANG GCpi: ± 0.55
BASIC VELOCITY PRESSURE: 29.85 psf
FOLLOWING WIND PRESSURES BASED ON Atrib: 50 SF
(5 psf DEAD LOAD USED IN CALCULATING UPLIFT)
ZONE 1 MWFRS: +32.12 psf
ZONE 2 MWFRS: -12.29 psf
ZONE 3 MWFRS: -27.61 psf
ZONE 4 MWFRS: -25.12 psf
ZONE 4 COMPONENTS & CLADDING 43.5/-45 psf
ZONE 5 COMPONENTS & CLADDING: 43.5/-45psf
16'x10' OHGD 39/-42.3psf
ROOF UPLIFT MOMENT 14.5 FT-LBF
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
\\\\\�� IF. I ICI
\P?PENSEe9/�i%
47�65 t'
Q i
NAV
11
: /MinNS DATE
\\\
5'0"
17' 0"
12'0"
34'4"
11'4"
5'8"
GARAGE 2110"
12' FLAT: CLG
0
16_Wx1HI_
ROLL _UP _
�A AUE DID i 4'8"
�2 0"
24' "
Metal
'I
Roof '
5
12 F E T
39/-42.
\4" OVERHANG
' FL EL
TABULATION AREA
GARAGE 824 SF
TOTAL 824 SF
PROTECTION OF OPENINGS
BASED ON FBC SECTION 160614 1 EXTERIOR OPENING THAT RECEIVES
POSITIVE PRESSURE SHALL BE PROTECTED WITH AN IMPACT RESISTANT
COVERING MATERIAL THAT MEETS THE REQUIREMENT OF SSTD12
ASTME1886 AND ASTME1996 OR MIAMI-DADE PA201,202 & 203
NOTE:
BLOCK LAYERS / FRAMERS TO CONSULT W/CONTRACTOR
FOR ROUGH OPENINGS OF WINDOWS AND DOORS
DOOR SCHEDULE
DR #
SIZE
ROUGH OP
QUANTITY
REMARKS
Di
3'0"x6'8"x11/4"
3' i12"x6'9"
3
EXTERI❑R DR
GA1
16'0"Wx10'0"H
16'0'WxlO'O'H
1
ROLL UP
WINDOW SCHEDULE
SIZE W xH
ROUGH OP
ROUGH OP
QUANTITY
REMARKS
MANUF.
MODEL
POURED SILLS
PRECAST SILLS
W1
24116 x 24%
25'74 x 25%
NOTES
Installation Flange Frame Window in. Concrete or Masonry Opening
When opening employs a 2x4 structural wood buck#10
Wood screws of sufficient length to achieve 1 3/8 in
min embedment into wood buck
When Opening employs a non-structural 1x4 wood buck
rein 3/16 in dia, Tapcons of sufficient length to achieve
11/4 in min, embedment into masonry or concrete
Number of anchors calculated not to exceed 24 in on center
F. Oy
Q � V�;Cr� dLOWD
w
�� w\
F �
S%9 ONA1 \�a\��
I N" ISIONS DATE
GONZALO ZAMUDIO DESIGNED BY AC
ABRAHAM CHABAB, Inc. GARAGE
E Corner of Arnold & 38th St. DRAWN BY
FL. BOARD OF PROF. ENG. AUTH.#26790
PIN 2420-224-0002-0008 AC
5428 NW EDGEWATER AVE DATE
PORT ST. LUCIE FL. 34983 FLOOR PLAN/ 6 / 1 / 2 0
Email agchababl@msn.com ELEVATION PLAN
772 878-5079/475-6630 DESIGN PRESSURE SHEET 2 ❑F4
Fax 772 785 8291
V4
SEC
'8"
#5 REBAR
X SPACING
5 FT O.C.
4 IN THICK C❑NCX2500 PSI rain )
W/LAYER 6x6 WWM ❑R'FIBERME H
C❑NC, OVER 6 MIL POLY VAPOR
BARRIER OVER CLEAN COMPACTED
34'4" P❑IS❑NED FILL
Z
' #5 REBAR
MAX SPACING
5 FT O.C.
1�'Wx1Q'H_RDI4Iz UP___
-- GARAGE DR.
10" 16'0' 1210"
24'0"
FOUNDATION
NOTES
Prepare
'slab to recieve 41n concrete
2500
PSI
with Layer 6X6 wmm 6 MIL
poty
vapor
barrier over ,clean compacted
soil
treated
for termite'
SEC A -A
NTS
FOUNDATION PLAN
SCALE 1/4 -1'0"
34
2'0"
'4'
GARAGE
12' FLAT CLG
L8
E
4, 20,0
24'0"
PRECAST LINTEL LA OUT
8"x24" Tie Beam
z: w/6#5 Rebar
w/#3 stirrups ® 12"
3000 PSI Concrete
8,<
J
12
S
Metal Roof on 30# Felt
*Soffit Shall Consist of 7/43 on 1/2 in CDx Plywood
on PRE ENG Wood Trusses
Cement Stucco over Wire 24 in O.C.
Lath w/11Ga.x2" long Nails
w/ 3/f3" head @ 6" O.C. Over See Connect
fig" Metal Rib Lath ® 6" O.C. sched
B
�c Provide (2) Layers of #15 Felt
Over Each Framing Member B. 6„ x16 Tie Beam
:• . w/4#5 Rebar
w/#3 stirrups ® 12"
* 21A� AL. Drip Edge 3000 PSIconcrete
Over 1x3 P.T. Nailer:I
4"
* 1x8 Fascia Boar
I
* 2x4 Cont. Sub Fascia Borad
Nailed to Truss Tail w/(2)
16d Nails (Or Better)
12'0'
8"x16" Concrete Blk
w #5 Vertical Dowel
in Conc. Filled Cells
as per Plan
i
24inx16in Mono
)[rooting w/3#5
Rebars Continuos 4„
SIN
Finished Grade 16:: ' 36 REHABS in 2500# Fibermx Conc.
w B in 1Ox10 w.w.m. on
006 Vapor Bearier 'on Clean
IFCompacted, Termite Treated
�24 ",P'Ill
PRECAST LINTEL TABLE
LINTELM
LENGTH
TYPE
QUANTITY
ALLOWABLE
GRAVITY LOAD
(LB)
APPLIED
GRAVITY
LOAD(LB>
SAFE UPLIFT
UPLIFT LOAD
(LB)
APPLIED
UPLIFT
LOAD (LB)
BEAM
COMPOSITE.
FILLED
REMARKS
L1
PRECAST
1
628E
400
8F16/1B1T
Y
1#5 REBAR
L2
'0
PRFr.ART-
625E
1# R BAR
L3
4'6'
PRECAST
—6222
1978
#5 RFRAR
L3A
4'6"
PRECAST
-
3086
2918
3455
1956
8F6/1B
Y
i#
AR
L4
5'0'
PRECAST
1
6200
1865
5256
475
Y
1#5 REBAR
L6
a
PRECAST
-
6110
10
200
Y
1#5
REBAR
L7
'
PRECAST-
610E
101E
524e
200
gFj r,11 gi T
Y
1#5 REBAR
L7A
6'6'
PRECAST
—
3028
540
3514
439
Y
1#5 REBAR
L7B
6'6"
PRECAST
-
2354.
275
1340
230
1 8F4/1B
Y
1#5 REBAR
L8
7'6'
PRECAST
1
! 604E
3398
5406
Y
1#5
REBAR
L8A
7'6'
PRECAST
-
I2998
398
3
520
8F6/1B
Y
1#5 REBAR
L10
9'4'
PRECAST
-
444E
1200
3888
2800
8F12/1B1T
Y
1#5 REBARS
L11
10'6"
PRECAST
-
5862
1959
5586
1316
8F16/1B1T
Y
1#5
REBAR
L13
'PRECAST
-5772
-5676
-
4
'
-
4936
L15
'
PRESTRESSE
—
9455
3500
5996
750
RF16Z1BIT
Y
1#5 REBAR
* USE CAST CRETE MATERIAL
CONNECTOR SCHEDULE
TRUSS
MEMB,
BEARING
POINTS
TRUSS M0
UPLIFT t
LD(LB)
TRUSS MAX
GRAVITY I
LD(LB)
CONNECTOR
ID
CONNECTOR
ALLOWABLE
UPLIFT LD(LB)
NAIL TYPE
FASTENERS
REMARKS
DESCRIPTION OF
8F16/1B1T
BY CAST CRETE FILLED
W/MIN 3000 PSI GROU
TO FORM A CONC. BEAM '
HIGH STRENGTH LINTELS
FILLED W/ GROUT QUANTITY [IF
5 REBAR 8
NORMAL WIDTH OP BLOCK
�i 16/1 B T
NORMAL HIGH LUANTITY OF
LLLiiiiii������ 5 REBAR e
BOTTOM LINTEL
X USE SIMPS❑N META18/14 ANCHOR
(CONCRETE
TO WOOD TRUSS MEMBERS)
WITH 8-10di(1/2)' NAILS EMBEDDED INT❑ 8-IN
POURED C❑NC, BOND BEAM
-TRUSS MAX UPLIFT : 1234LB CONNECTOR UPLIFT
META18/14 :1450 LB
-DIFFERENT ANCHOR IS REQUIRED FOR TRUSS
MEMBERS THAT ARE
LISTED IN THE TABLE
USE SIMPS❑N LTS20 CONNECTOR ( BETWEEN
TWO WOOD MEMBERS)
WITH 12-IOD NAILS TO THE PLATE AND 12-10Dx11/2 NAILS FOR
THE TRUSS MEMBERS.
-TRUSS MAX UPLIFT 1425LB CONNECTOR UPLIFT
SIMP LTS20: 620 LB
-DIFFERENT ANCHOR IS REQUIRED FOR TRUSS
MEMBERS THAT ARE
LISTED IN THE TABLE
GONZALO ZAMUDIO
DESIGNED BY AC
BRAHAM CHABAB, Inc.
4L.JBOARD
GARAGE
Q
SE Corner of Arnold & 38th St
DRAWN BY
OF PROF. ENG. AUTH.#26790
PIN 2420-224-0002-0008
AC
5428 NW EDGEWATER AVE
PORT ST.; LUCIE FL. 34983
FOUNDATION ' PLAN
DATE
6 / 1 / 2 0
WALL HEIGHT'S LINTEL
Email agchababl*msn.com
Ph 7Fax87725085-8291 8630
& WALL DPTAILS
SHEET 3 OF 4
CONNECTOR SCHEDULE
IFI'Ch/�ii
Qp'r`�cENse qey/l
Q .. No q Q' f l'—
o . �, —
3 PI ORI�P
/
////'9 ON'A1.\E\���
REVISIONS JDATE.'
00f%#U e
SPAN
MINIMUM
PITCH
BOTTOM CHORD
LATERAL BRACE
SPACING (LBs)
BOTTOM CHORD
DIAG❑NAL BRACE
SPACING (DBs)
#TRUSSES
SP/DF
SPF/HF
UP
TO
32'
4/12
15'
20
Ib
32'-48'
4/12
10
7
48'-60'
4/12
1 15'
❑VR 60'
T SEE A PR❑FESSI❑NAL ENGINEER
DF D❑UGLAS FIR -LARCH SP ; SOUTHERN PINE
HF HEM -FIR SPF: SPRUCE -PINE -FIR
\II lateral braces
3pped at least 2
trusses
WARNING : Failure to follow these recommendations could result in
severe personal injury or damage to trusses or buildings
STD HOOK BOND BEAM _1(1/2) MIN
VERT. REINF.
IN GROUTED
CELL
30"
MIN CLEANOUT REQ'D
LAP FOR GROUT LIFT
6" MIN
3" MIN
EMBEDMENT
_
COVER HOOK FOOTING
STD
REQ'D @ EACH END
OF SHEARWALLS OR
SHEARWALL SEGMENTS
I
DOWEL LAPPED
W/WALL REINF.
ALL LAPS MIN 30"
GROUTED CELL 1 #5 CORNER BAR
s bracing repeated at
end of the building
d at 20'intervals
STD HOOK
BOND BEAM
2 FILLED CELLS
1 #5 EACH CELL
BOND BEAM
12" MIN
8d RINK SHANK NAILS
8d RINK SHANK
°
° °<
ALL STRUCTURAL SHEATHING
PANELS TO BE 1/2" MIN.
THICKNESS (4-PLY) CDX °
° ° °<
o 0 ° ° ° °
° °°
° ° ° °
°
° o °
° °°
° ° ° ° °
° o °
° °
° ° ° ° °
° °°
° ° ° ° ° °
0
►.• • OR ■_ILI 1CM WM9111
1 1"
GAP
PRE-ENG.
TRUSSES
.2x4 BLOCKING
BEf.ALL TRUSSES
RIDGE BLOCKING DETAIL
0
i
0
0
°
0
8d RINK SHANK NAILS
@ 5" O.C. IN ZONE(9) UO
8d RINK SHANK NAILS
@ 7" O.C. IN ZONE 1�
i
---------i-------------7-------
1 #5 DOWEL IIN CORNER
i
---------� --2-
0
GENERAL NOTES:
1-The contractor shall provide all labor ,materials, connectors , supplies and shall perform
all operation for the complete and total installation of all construction work shown and
or implied on the drawings , including but not limited to the following any appliance
and/or if called for in detail , without additional cost to the owner.
2-The contractor shall verify dimensions and job conditions prior to submitting bids and
report to the engineer any discrepancies and/or omissions which would interfere with the
satisfactory completion of the work , as detailed on the drawings and or specified herein.
3-Drawings are not to be scaled for accuracy of placement or location due the nature of
reproduction process. Improper placement shall be the responsibility of the contractor to
repair.
4-All work shall be of sound construction, consistent with the best building practices of the
individual trade.
5-All materials shall be new and unused (unless otherwise noted for relocation or installation)
All defective materials furnished and/or installed by the contractor shall be removed and
replaced at the contractor's expense without delay of work.
6-All materials or equipment utilized on the job shall comply with the requirement of the
latest edition of the APPROVED Local Building Code , The National Electrical and Plumbing
Codes , Disability Act , Florida Access Code and all Local Codes and Ordinances as may
apply to any portion of the work .
7-The contractor shall remove any debris as it accumulates and shall not allow discarded
materials to accumulate. Each Sub -contractor shall be responsible to police their area
of work and pick up their discarded materials and waste .
8-All necessary inspection certificates , permits and licenses as may be required are to
be obtained at the contractor's expense .
CONTINUITY OF FOOTING
REINFORCEMENT
SIGNING & SEALING OF PLAN BY ENGINEER IS FOR REVIEW OF COMPLIANCE
WITH 2O17 (FBC) FLORIDA BUILDING CODE AS APPLICABLE FOR THE SPECIFIC
RESIDENCE AND ONLY VALID IF IT BEARS THE SIGNATURE DATE & RAISED
EMBOSSED SEAL OF THE DESIGN ENGINEER. THE ENGINEER DOES NOT
ACCEPT TOTAL RESPONSIBILITY FOR ALL DESIGN/SPECIFICATIONS RELATIVE TO
THIS ENTIRE STRUCTURE & SPECIFIC SITE LOCATION INCLUDING BUT NOT
LIMITED TO ELECTRICAL, PLUMBING, HVAC, SURVEY INSPECTIONS, ENERGY
CODE , GRAVITY LOADS AND SO FORTH UNLESS OTHERWISE REFLECTED OR
INDICATED ON THE PLAN
MATERIALS/COMPONENTS GENERALLY CONSIDERED AS MANUFACTURED OR
PREFABRICATED ARE NOT A PART OF THE ENGINEER'S CERTIFAICATION .
MATERIAL APPROVALS SUCH AS BUT NOT LIMITED TO TRUSSES, TRUSS
OVERHANGS, HEADERS, WINDOWS, GARAGE DOORS , LINTELS , WINDOWS
GLAZING , HURRICANE ANCHORS ALUMINUM SOFFITS/FASCIA, DOORS,
SLIDING AND FRENCH DOORS ARE NOT PART OF THE ENGINEER'S
CERTIFICATION AND SHALL BE APPROVED BY THE MANUFACTURER OR
VENDOR WHEN REQUIRED BY LOCAL BUILDING CODE.
FINAL DESIGN OF PLUMBING, ELECTRICAL AND HVAC DESIGN THAT MAY
BE REFLECTED ON PLANS SHALL BE THE RESPONSIBILITY OF OTHERS
AND SHALL BE INSTALLED BY THE APPROPRIATE SPECIALTY CONTRACTORS
THESE CONTRACTORS ACCEPT RESPONSIBILITY FOR FINAL DESIGN AND
CONSTRUCTION UNLESS OTHERWISE NOTED.
VERIFICATION OF ALL DIMENSIONS BEFORE ORDERING MATERIALS AND
START CONSTRUCTION IS THE RESPONSIBILITY OF THE APPLICABLE
CONTRACTOR OR OWNER. ANY DISCREPANCIES SHOULD BE BROUGHT TO
THE ATTENTION OF BUILDING DESIGNER AND ANY CHANGES THAT WILL
BE MADE ON SITE.
m;
u471�
i� F ................
/SS/ O N A\-
`
GONZALO ZAMUDIO
DESIGNED BY
ABRAHAM
CHABAB, Inc.
GARAGE
AC
SE Corner of Arnold & 38th St.
DRAWN BY
FL. BOARD OF
PROF. ENG. AUTH.#26790
PIN 2420-224-0002-0008
AC
5428
NW
EDGEWATER AVE
DATE
PORT
ST.
LUCIE FL. 34983
DETAIL PLAN
6/1/20
Email
772
agchababl®msn.com
878-5079/475-6630
GENERAL NOTES
SHEET ❑F
Fax
772
785-8291
ic11