Loading...
HomeMy WebLinkAboutProduct Approval; Single Hung Windows8/27/2020 Florida Building Code Online �. LINT PF d ff + 94 Re, . Y BCIS Home Log In ' User Registration Hot Topics I Submit Surcharge ( Stab; & Facts I Publications I Contact Us BCIS Site Map, Links Search Florida - Product Ap proval a -USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail •- + FL # FL14911-R1i Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Silver Line Building Products Corp. Address/Phone/Email One Silverline Drive North Brunswick, NJ 08902 (732)435-1000 jonberrian@slbp.com Authorized Signature Jon Berrian jonberrian@sibp.com Technical Representative ]on Berrian Address/Phone/Email One Silverline Drive North Brunswick, NJ 08902 (732) 435-1000 jonberrian@slbp.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report -Hardcopy Received Florida Engineer or Architect Name who developed the Hermes F. Norero, P.E. ' Evaluation Report Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 08/03/2021 Validated By Locke Bowden P.E. ? Validation Checklist - Hardcopy Received Certificate of Independence FL14911 R11 COI COI Silverline SS 2017-06-14 pdf Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440 2008 AAMA/WDMA/CSA1101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 ASTM E1996 FILE Copy 2006 ASTM E1996 ��++++ 2009 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 hftps://floridabuilding.org/pr/pr app_otl.aspx?param=wGEVXQwtDquZRj59%2fDrx2lbtdSCx8gXOAG%2bvoMHV6Fk8dHGU%2f4khcg%3d%3d 1/3 8/27/2020 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/17/2018 Date Validated 10/14/2018 Date Pending FBC Approval 10/08/2018 Date Approved 10/18/2018 FL # Model, Number or Name 14911.1 Vl Series/50 Series (2000) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use. 14911.2 I V1 Series/50 Series (2111) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use. 14911.3 I VI Series/50 Series (2200/2300) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use. 14911.4 I VI Series/70 Series (2127) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use. Description Single -Hung Window Installation Instructions FL14911 R11 II SWD017 SS 2018-10-11 pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL14911 R11 AE EER5140 SS 2017-10-20 pdf Created by Independent Third Party: Yes Single -Hung Window Installation Instructions EL14911 R11 II SWD018 SS 2018- 0-11 pdE Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL14911 R11 AE PER5141 SS 2017-10-20 pdf Created by Independent Third Party: Yes Single -Hung Window Installation Instructions FL14911 R11 II SWD019 SS 2018-10-11 pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL14911 R11 AE PER5142 SS 2017-10-20 pdf Created by Independent Third Party: Yes Single -Hung Window Installation Instructions FL14911 R11 II SWD049 SS 2018-10-11 pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL14911 R11 AE PER5485 SS 2018-02-14 pdf Created by Independent Third Party: Yes 14911.5 Vi Series/70 Series (2127) Single -Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL14911 R11 II SWD050 SS 2018-10-11 pdf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911 R11 AE PER5486 SS 2018-04-19.pdf Report for allowable design pressures, sizes, installation Created by Independent Third Party: Yes requirements and limits of use. 14911.6 I VI Series/70 Series (2907/4907) Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Single -Hung Window Installation Instructions FL14911 R11 II SWD053 SS 2018-10-11.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquZRj59°/`2fDrx2lbtdSCx8gXOAG%2bvoMHV6Fk8dHGU%2f4khcg%3d°/*3d 2/3 . 8/27/2020 o Florida Building Code Online Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other., See Installation Instructions and Product Evaluation FL14911 R11 AE PERS884 SS 2018-08-17.pdf Report for allowable design pressures, sizes, installation Created by Independent Third Party: Yes requirements and limits of use. Back tdext Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 phone: 850-487-1824 The State of Florida is an AA/EEO employer. Cop aright 2007-2013 State of Florida.:: Privagy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M ON Den" SeCiLtrlt y,,.tr�."fFLics- hftps://floridabuilding.org/pr/pr app_Otl.aspx?param=wGEVXQwtDquZRj59%2fDrx2lbtdSCxBgXOAG%2bvoMHV6FkBdHGU%2f4khcg°/a3d%3d 3/3 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 S VA 398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Silver Line Building Products Corp. V1 Series / 70 Series Single -Hung Window (2127) (Impact) (HVHZ) for Florida Product Approval Current Florida Building Code Method: Category: Sub — Category: Product: Material: Product Dimensions: 1— D (Engineering Evaluation) Windows Single Hung V1 Series / 70 Series Single Hung Window (2127) PVC See Installation Instructions, SWO050 Prepared for: Silver Line Building Products Corp. One Silverline Dr. North Brunswick, NJ 08902 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date: 01/23/2018 Contents: Evaluation Report Pages 1— 3 Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2018.04.19 00:55:47-04'00' O Vell E S '•O N 7 00 S A OF ; Q: � w� •� OT O IDP .� � HermfllVolrAE. Florida No. 73778 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Manufacturer: Silver Line Building Products Corp. Product Category: Windows Product Sub -Category: Single Hung Compliance Method: State Product Approval Method (1)(d) FL#: FL14911 Date: 01/23/2018 Report No: 5486 Product Name: V1 Series / 70 Series Single Hung Window (2127) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line Building Products Corp. based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD050, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing SWD050 require further engineering analysis by a licensed engineer or registered architect. S. See Installation Instructions SW13050 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 3 BUILDING DROPS FL#: FL14911 A Perfect Solution in Every Drop! Date: 01/23/2018 Certificate of Authorization: 29578 Report No: 5486 Quality Assurance: The manufacturer has demonstrated compliance of window products in Accordance with the Current Florida Building Code and State Rules for manufacturing under a quality assurance program audited by an approved quality assurance entity through Window and Door Manufacturers Association (FBC Organization #: QUA2515). Performance Standards: The product described herein has been tested per: Referenced Data: Installation: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06/09/12 • AAMA/WDMA/CSA 101/I.S.2/A440-08 1. Product Testing performed by National Certified Testing Laboratories, Inc. (FBC Organization # TST1589) Report: Dated: NCTL110-16327-1 08/13/2013 Signed and Sealed by: Harold E. Rupp, FL PE No 15935, Sealed Date 02/06/18 NCTL 110-16327-2 11/05/2013 NCTL 110-16327-3 08/13/2013 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization #: QUA2515) 3. Material Certification Miami -Dade County Notice of Acceptance Eastman Chemical Company (Previously Solutia) Saflex (Vanceva Composites) PVB Interlayer 4. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance with AAMA 303 Refer to Installation Instructions (SWD050) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions (SWD050) for anchor spacing and more details of the installation requirements. Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 3 SILVER LINE BUILDING PRODUCTS CORP. V1 SERIES170 SERIES SINGLE HUNG WINDOW (2127) (IMPACT RATED) (HVHZ) GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN 15 DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT EDITION FLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06/09/12 • AAMA/WDMA/CSA 101/I.S.2/A440-08 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X FRAMING, AND METAL FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION 15 THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON-HVHZAREAS. IN HVHZAREAS, ONE TIME PRODUCT APPROVAL TO BE OBTAINED FROM MIAMI-DADE RER OR AHJ. S. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: PVC 7. IN ACCORDANCE WITH THE CURRENT EDITION FBC, WOOD COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED OR SHALL BE OF DURABLE SPECIES AS DEFINED IN CHAPTER 23. S. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS. SEE SHEET 1 FOR GLAZING DETAILS, MAX OVERALL SIZE CONFIG. DESIGN MISSILE WIDTH HEIGHT PRESSURE IMPACTRATING 52" 73" O/X +SS / -60 PSF LMI/SMI TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 - GENERAL NOTES & GLAZING DETAIL 2 - ELEVATION & ANCHOR LAYOUTS 3 - VERTICAL SECTIONS 4 - HORIZONTAL SECTIONS 5 HORIZONTAL & VERTICAL SECTIONS, INSTALLATION NOTES & REINFORCEMENT DETAILS EXTERIOR STEELSPACER 1/8" OR 3/32" SETTING BLOCK Silver Line MArid r�ri" ONE SILVERLINE DRIVE ' NORTH BRUNSWIM NJ 08902 8 C, 2 <, it 0 00 Z oz g o g ?� ZSsg� sz z19 =A m w �x DO m a W F a 43/64" O.A. I.G. LAMINATED GLASS Reason, 1phi' 86ty ant Date`,''18 38. CONSISTING OF: 1/8"ANNEALED GLASS 7/32" STEEL SPACER ��� .•'�� E�• i : • V� `� •• �0 3/32" ANNEALED GLASS 0.090" SAFLEX PVB INTERLAYER BY + .� N `.7 % IT EASTMAN CHEMICAL COMPANY 3/32" ANNEALED GLASS -0.. S A :OF' ? o b. INTERIOR Zll MMl�lslde FUMA P.E. No 73M aOLDIN DROPS. IND 385E. DANIA eEAW BW0. 339 DANIA SEAO1, R. 3300� rePE CERT. OF AU711DRI7ATION Na. 29M FLH. MIN. GLASS F L14911 BITE 7/16" 1995 SEALANT DATE: 01.23.18 GLAZING DETAIL 1 HH NOTE: SCALE: NTS ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH DWG. N: SW D SAFETY GLAZING REQUIREMENTS OUTLINED IN SHEET: CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. I MAX.O.A FRAME WIDTH 52" MAX. D.L.O. WIDTH 47.69" A B 3 3 MAX. D.LO. HEIGHT33.50" C AX. O.A FRAME HEIGHT 73" 144 D MAX. MILD. HEIGHT 33.50" X. ELEVATION SINGLE HUNG WINDOW 3" MAX. 6" MAX. 6.25" MAX. FROM O.C. FROM {�- CORNERS r CORNERS I 1 NOTE: 1- ALL FASTENERS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB 6" MAX. ,�O„ TRACK MUST BE FLAT HEAD O.C. 3" MAX. FROM CORNERS t 1 12.50" MAX. O.C. X" 6.25" MAX. FROM CORNERS L I ANCHOR LAYOUT NAIL FIN -SINGLE HUNG WINDOW ANCHOR LAYOUT THROUGH FRAME - SINGLE HUNG WINDOW Silver Line erAncffrW ONE SILVERUNE DRIVE NORTH BRUNSVACK, NI08902 PH: 800 2344228 Z,, o Y S 2 N �V W o .0 o♦ G WO x ZV Z p8b_^9 made Z C3Z !; L9 o , Z oeZ = O m > � w a 1= W a I 398 E.DAHA BFAOH'BUV. 338 DANIA BUM FL 3300� FBPE CRT. OF AUTHORIZATION Nn 20M FL A: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: HR HFN SCALE: NTS DWG. a: SWD050 SHEET: EE GLAZING ETAIL, SHEET 1 INTERIOR SEE GLAZING DETAIL, SHEET 1 rA--� VERTICAL SECTION 3 NAIL FIN EE GLAZING ETAIL, SHEET 1 INTERIOR SEE GLAZING DETAIL, SHEET 1 rB-"\ VERTICAL SECTION 3 THRU FRAME Silver Line. byMffi i ONE SILVERUNE DRFVE NORTH BRUNSIMCR, N10B90i PH: B00 2344228 z l7 n z ry E Vl 2 G 0. 0z �3 S W z x ? D3 m O / OC j F REMARKS 77 I BY DATE 3B3 E. DANIA BEACH B.W. f 33B DANIA BEACH, FL 33004 FHPE CERT. OF AUDIORMATION N. 29M FL #: FL14911 DATE: 01.23.18 DWG. BY: CHK BY: HR HFN SCALE: NTS DWG.#: glAln qn I [fig SECTION FOR BLOCK & TACKLE 1 BALANCERS GLAZING AIL SHEET 1 SEE GLAZING CETAILSHEET i INTERIOR SEE GLAZING DETAIL SHEET 1 \ EXTERIOR I� D.L.O. MAX. FRAME WIDTH HORIZONTAL SECTION 4 UPPERSASH SEE GLAZING INTERIOR DETAIL SHEET 1 EXTERIOR D.L.O. MAX. FRAME WIDTH p�HORIZONTAL SECTION 4 LOWER SASH SECTION FOR CONSTANT FORCE 1 BALANCERS Silver Line byMcWM ONE SRVEflUNE DRIVE NORTH BRUNSWIM NJ 09902 PH: 800 234J228 i. ID Z l7 Z N 2 E Vl VI .N.. W3 O c � s3 uWip Leg- 3 in pW , O OC Z = G m DO .t...� .-I a < REMARKS I BY DATE FLORIDA Pm ��i+LOR1?di` Pm P.E: No 7me ewu>ea oPDPa u C ]Pe E: NIA AM F BLW. Ste i EHPE CFAT. OF AUllIDRQAl10N No 2057e k FL #: FL14911 DATE: 01.23.18 DWG. CH HFN SCALE: NTS DWG. a: SWDOSO SHEET: j OF j MIN. SUBSTRATE EDGE DISTANCE BY OTHERS MIN. EMBEDMENT RIMETER SEALANT o —� 1/4" MAX BY OTHERS SHIM SPACE EXTERIOR INTERIOR A� VERTICAL SECTION 6 THROUGH FRAME (HEAD) 1/4" MAX. SUBSTRAT SPACE BY OTHERS z INTERIOR EXTERIOR z_ I EXTERIOR 1/4" MAX. SHIM SPACE INTERIOR PERIMETER SEALANT BY OTHERS EXTERIOR BY OTHERS SCREW IN THE INTERIOR 'CHANNEL MIN. EDGE DISTANCE SCREW IN THE EXTERIOR CHANNEL MIN. EMBEDMENT g1)HORIZONTAL SECTION 6 THROUGH FRAME (JAMB) 0.83" 0.77" 0.9" INTERIOR T- OLOCK RAIL TOP O ALUMINUM MIN. EDGE DISTANCE HORIZONTAL SECTION rE-'� VERTICAL SECTION 6 NAIL FIN (JAMB) 6 MEETING STILE INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF t1/21NCH THE DEPICTED LOCATION & SPACING IN THE ANCHOR LAYOUT DETAILS (I.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 3/81NCH. SHIM WHERE SPACE OF 1/161NCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. S. FOR MASONRY OR CONCRETE OPENINGS, 1X WOOD BUCK MAY BE USED (OPTIONALAS LONG AS THE MINIMUM EMBEDMENT AND EDGE DISTANCE REQUIREMENTS ARE STILL MET WITHIN THE CORRESPONDING HOSTSUBSTRATE. SEE GENERAL NOTE #3 ON SHEET 1 FOR MORE INFORMATION. 6. MINIMUM EMBEDMENTAND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 8. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BYTHE ANCHOR MANUFACTURER. 10. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK, USE FLAT HEAD ANCHORS. MIN. EMBEDMENT SUBSTRATE BY OTHERS W a U w Q r5�;INTERIOR 1/4" MAX. SHIM SPACE EXTERIOR HORIZONTAL SECTION 6 NAIL FIN (HEAD) REINFORCEMENT DETAILS 0.87" T--� 0.06" 0.45" LOCK MEETING RAIL O ALUMINUM 0.34" ►� h� 0.46" 0.87" Silver Line. IaAhde"fgffi E B--' ONE 51LVERUNE DRIVE NORTH BRUNSWIM NJ 0E902 vW ` N,yF 0 �. tr 3_ 0p Pzz OZ joW �3 � u. �L7 1aH-.aF0 w Z 2 N 2 H O Z - �a } DO u = o m to t a (:. F W a REMARKS BY DATE BOTTOM LIFT RAIL & SASH ALUMINUM AReMA.Ne* ANCHORSCHEDULE METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT MIN. EDGE DISTANCE WOOD: MIN. SO = 0.55 08 WOOD SCREW 1.5' 0.76' PAN HEAD NAILING FIN METAL' IS GAUGE Steel, NS TEKSCREW 3 THREADS MIN MIN. Fy = 33KSI PENETRATION BEYOND 0.60' METAL #10 PAN HEAD W 1.5' 0.75' EXTERIOR CHANNEL WOOD: MIN. SO = 0.55 $10 FLAT HEAD IN THE INTERIOR CHANNEL 1 S 0.75' #10 PAN HEAD IN 3 THREADS MIN EXTERIORCHANNEL PENETRATION BEYOND 0.50' THROUGH FRAME METAL..13 GAUGE Steel, METAL MIN. Fy= 33KSI NIN FLAT HEAD IN THE 3 THREADS MIN INTERIOR CHANNEL PENETRATION BEYOND O.SO' METAL CONCRETE P-3000PSI 3N6'ITWTAPCON 12S 1.75 FLAT HEAD AS 3H6'ITWT-CONR5 1-.&NRY:CMUPer MW.2000 P51 FLATHEAD 17S JOB E DANIA WADI BLVD. / 338 oANIA BEACH. FL 33004 RIPEBEACH. CERT. OF AUTHORIZATION Na 2957E FL #: FL14911 DATE: 01.23.18 SCALE: NTS DWG. #: SW D050 SHEET: