Loading...
HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door Assemblies8/27/2020 Florida Building Code Online Business o . 0 BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Florida Product Approval pr USER: Public User Ar Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL22513-R2 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency • Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Masonite International 1955 Powis Road West Chicago, IL 60185 (800) 663-3667 sschrelber@masonite.com Steve Schreiber sschreiber@masonite.com Exterior Doors Swinging Exterior Door Assemblies Certification Mark or Listing National Accreditation & Management Institute National Accreditation & Management Institute Standard TAS 201 TAS 202 TAS 203 Year 1994 1994 1994 Method 1 Option A FILE Copy Date Submitted Date Validated Date Pending FBC Approval 04/16/2018 04/18/2018 7 8/27/2020 Florida Building Code Online Date Approved 04/24/2018 Summary of Products I FL # I Model, Number or Name Description 22513.1 I HPC Wood -edge Steel Side -Hinged 6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o Door Unit I Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When impact resistance Is required, hurricane protective system is required. Door top rails stamped "HPC". See DWG-MA-FL0212 for details. Certification Agency Certificate FL22513 R2 C CAC NI013747 01-R1 pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL22513 R2 II FL0212.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22513 R2 AE 514008.pdf Created by Independent Third Party: Yes 22513.2 Wood -edge Steel Side -Hinged Door Unit 8'-0" Opaque I/S or O/S Single Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22513 R2 C CAC NI013747.04.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2021 Design Pressure: +70/-70 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0215.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 3'-0" x 8'-0" max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not FL22513 R2 AE 514009.pdf required. See DWG-MA-FLO215 for details. Created by Independent Third Party: Yes 22513.3 Wood -edge Steel Side -Hinged Door 8'-0" Opaque I/S Single or Double Door w/ or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22513 R2 C CAC NI013747.04.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2021 Design Pressure: +45/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0215.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 8'-0" max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not required FL22513 R2 AE 514007.pdf on opaque panels, but is required on glazed sidelites. See Created by Independent Third Party: Yes DWG-MA-FL0215 for details. 22513.4 Wood -edge Steel Side -Hinged Door 8'-0" Opaque O/S Single or Double Door w/ or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22513 R2 C CAC NI013747.04.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2021 Design Pressure: +50/-45 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0215.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 8'-0" max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not required FL22513 R2 AE 514007.pdf on opaque panels, but is required on glazed sidelites. See Created by Independent Third Party: Yes DWG-MA-FL0215 for details. 22513.5 Wood -edge Steel Side -Hinged Door 8'-0" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22513 R2 C CAC NI013747 06 pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +40/-40 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0217.pdf Building Code, including the High Velocity. Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 8'-0" max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system is required. FL22513 R2 AE 514007.pdf See DWG-MA-FLO217 for details. Created by Independent Third Party: Yes 2513.E I Wood -edge Steel Side -Hinged Door 16'-8" Opaque I/S or O/S Single Door 8/27/2020 Florida Building Code Online Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22513 R2 C CAC NI013747-Ri pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2021 Design Pressure: +70/-70 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0211 pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 3'-0" x 6'-8" max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not FL22513 R2 AE 514010 pdf required. See DWG-MA-FL0211 for details. Created by Independent Third Party: Yes 22513.7 Wood -edge Steel Side -Hinged Door 6'-8" Opaque I/S or O/S Single or Double Door w/ or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22513 R2 C CAC NI013747-R1 pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2021 Design Pressure: +55/-55 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0211 pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 6'-8" max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system not required FL22513 R2 AE 514008 pdf on opaque panels, but is required on glazed sidelites. See Created by Independent Third Party: Yes DWG-MA-FL0211 for details. 22513.8 Wood -edge Steel Side -Hinged Door 6'-8" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22513 R2 C CAC NI013747.03-R1 pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0214.12df Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 6'-8" max nominal size. When impact Evaluation Reports resistance is required, hurricane protective system is required. FL22513 R2 AE 514008.pdf See DWG-MA-FLO214 for details. Created by Independent Third Party: Yes Back N.1 Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Cgpyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® erhEc in '-G(0.'djt Card SeCt1I- i tY.lt1TRICS' L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC27023 434-688-0609 Manufacturer: Masonite Report #: 514008 Date: 05/01 /2017 rllomas @ Idomasoe.com Test Report. N/A Product: Double Door with and without sidelites 12'x6'8" (wood frame) Scope: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code. .Anchor capacity in shear condition: Solid members w/ 6 w/out gap: With threads present in shear plane Fastener type: #10 wood screw (ND5 2012, TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb = 80,000 psi Side member: Douglas Fir -Larch (G=0.50) Main member: Spruce -Pine -Fir (G=0.42) Side member thickness: t,= 1.000 in Main member thickness: t = 1.500 in Side member dowel bearing strength: Fv = 4,650 psi Main member dowel bearing strength: F_ = 3,350 psi Side member dowel bearing length: I, = 1.000 in Main member dowel bearing length: Im = 1.140 in Mode Im qm = 636.5 lbs/in P = 725.61 lbs Ka = 2.400 4= 302lbs Mode I. qs = 884 lbs/in P = 884 lbs Ka = 2.400 Z,= 368lbs Min. Design value: Z= 110 lbs Mode II Mode III, Mode III, Mode IV A: 0.00096 A: 0.00107 A: 0.0014 B: 0.57 B: 0.5 B: 0.000 C:-253.62 C: -267.7 C: -93.6 Ms = 46.8 in-lbs Mm = 46.8 in-lbs P = 297 lbs P = 319 lbs P = 263 lbs Ka = 2.400 Ka = 2.400 Ka = 2.400 Duration Factor: Ca = 1.6 Z= 124 lbs Z= 133 lbs Z= 110 lbs Allowable Design Value (ZQ: Z'= 175 lbs/anchor Solid members w/ 6 w/out gap: a. With threads present in shear plane A: 0.0007 B: 1.07 C:-427.67 P = 331 lbs Ka = 2.400 Z= 138 lbs Fastener type: #10 wood screw (ND5 2012, TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb = 80,000 psi Side member: Douglas Fir -Larch (6=0.50) Main member: Steel strap/clip Side member thickness: t,= 1.000 in Main member thickness: t„ = 0.048 in Side member dowel bearing strength: Fv = 4,650 psi Main member dowel bearing strength: FU = 61,850 psi Side member dowel bearing length: I, = 1.000 in Main member dowel bearing length: Im = 1.140 in Mode I. qm = 11752 lbs/in P= 13397lbs Ka = 2.400 Z.= 5582lbs Mode I, qs = 884 lbs/in P= 884 lbs Ka = 2.400 Z.= 368Ibs Min. Design value: Z= 163 lbs Mode II A: 0.0003 B: 1.07 C:-4038.9 P = 2287 lbs Ka = 2.400 Z= 953lbs Mode III A: 0.00059 B: 0.57 C:-3864.9 Ms = 46.8 in-lbs P= 2126 lbs K� = 2.400 Mode III, A: 0.00033 B: 0.5 C: -267.7 Mm = 46.8 in-lbs P= 420lbs Ko = 2.400 Mode IV A: 0.0006 B: 0.000 C: -93.6 P= 392 lbs Ka = 2 400 Duration Factor: Ca = 1.6 Z= 886 lbs Z= 175 lbs Z= 163 lbs Allowable Design Value (ZCo): Z.= 262 lbs/anchor Fastener type: 1/4' ITW Tapcon N.O.A.16-1222.06 Substrate: Hollow block Minimum embedment: 1.25 in Edge distance: 4.00 in Tabulated shear design value: Z = 202 lbs Edge distance: 2.00 in Tabulated shear design value: Z = 161 lbs Actual edge distance: 2.50 in Reduction factor: 0.85 Spacing: 4.00 in Tabulated shear design value: Z = 202 lbs \`�� [�■ Spacing: 2.00 in Actual spacing: 3.00 in Tabulated shear design value: Z = 164 lbs \ ■ • V ■ �` �` Allowable Reduction factor: 0.91 C E -^ �� e�� %9 ! do Design Value f N)' 9 CZ � Z"= 155 lbs/anchor Minimum anchor capacity: 155 lbs/anchor _ y • - 7� 0 • # Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. 'c TAT OF ,• ?0'�F':c�OR1�P' N '. \ lissIVNAt ///// if I l0�� 1 of 3 Luis R. Lomas P.E. FL No.: 62514 5/2/2017 L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC27023 Manufacturer: Masonite Report #: 514008 434-688-0609 Date: 05/01/2017 rilomas@Irlomaspe.com Anchor calculations. minimum required anchors 36.38 36.38 A7 Al AzY YAz179.25 Al Al 72.75 37.50 36.38 36.38 37.50 �11' YYY� A A Al 147.75 Anchor Locations: 79.25 Design pressure: 60.0 osf Zone Area 2 (ft) Load (Ibs) Ind. (in)(In) Max. O.C. Anchor Result Cap. (Ibs) Qty Load (Ibs) AI 2.3 138 N/A N/A 155 1 138 1 OK A2 7.7 463 6.00 21.00 155 5 93 1 OK A3 7.7 463 N/A N/A 155 3 154 OK Design pressure: 60.0 psf Zone Area 2 (ff) Load (Ibs) Ind. (in) Max. O.C. (in) Anchor Result Cap. (Ibs) Qty Load (Ibs) AI 2.4 146 N/A N/A 155 1 146 OK A2 7.9 473 6.00 21.00 155 5 95Ifl A3 7.8 468 N/A N/A 155 4 117A4 2.3 138 N/A N/A 155 1 138A5 7.7 463 N/A N/A 155 3 154 Double door 36.38 36.38 6.00 TYP. 6.00 TYP. 18.19 TYP. 3.00 TYP. j 6.00 13.45 MAX. O.C. 79.25 6.00 Luis R. Lomas P.E. FL No.: 62514 2 of 3 5/2/2017 L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC27023 434-688-0609 Manufacturer: Masonite Report #: 514008 Date: 05/01 /2017 rilomas@lrlomasr)e.com Double door with sidelites 6.00 TP. 37.50 18.75 T R 6.0.0 NP. 3.00 TP. 36.38 18.19TP. 36.38 37.50 6.00 1345 MAX O.C. 125 5.00 Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE 410 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. \' ` lb P, I l.L/�,�/��i fi NN cp • 0 51 TAT OF ,•w ONA i 3of3 Luis R. Lomas P.E. FL No.: 62514 5/2/2017 r)ll MASONITE WOOD -EDGE STEEL DOOR UNIT 6 =6" DOUBLE DOOR WITH / WITHOUT SIDELITES GENERAL NOTES 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS NOT REQUIRED ON OPAQUE PANELS, BUT IS REQUIRED ON GLAZED SIDELFFES. 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ), HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE PANELS OR PANELS WITH IMPACT GLASS, BUT IS REQUIRED ON PANELS WITH NON -IMPACT GLASS. L. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. i. PLASTICS TESTING: TCM 11CCnoiannr.i nrnni SELF IGNITION TEMP ASTM D1929 842 -F > 650 -F RATE OF BURNING ASTM D635 1.28 IN MIN SMOKE DENSITY ASTM D2843 70.27. TENSILE STRENGTH- 1. ASTM D638 1.8% DIFF UUMNANATIVE TENSILE STRENGTH AFTER WEATHERING 4500 HOURS XENON ARC METHOD 1 o� SINGLE DOOR UNIT 149' MAX. OVERALL FRAME WIDTH 0- 00 O 21" MAX 36.375" MAX. U — D.L.O. — PANEL WIDTH 37.5" MAX. W/ASTRAGAL FRAME WIDTH 0 J cc ® ® ® ® U Lu LOU = 2 a Lo MIMI Ad DOUBLE DOOR UNIT W/SIDEL(TES �I o DOUBLE DOOR UMT SINGLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT WISIDELITFS WITH SIDEL[TE WITH SIDELI7E WHERE WATER INFILTRATION PERFORMANCE IS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE CONFIG MAX WIDTH INSWING OUTSWING INSWING BUMPER 0 S Z-SERIES 0 S I HIGH DAM 0 S 4 LIMP OX 37.5 74 +70.0 -70.0 +70.0 -70.0 N A 0.0 -20.0 +-50.0 +50.0 -0 300. +500 0S.0XX -.5. XO 75 +55.0 -55.0 +55.0 -55.0 N A 0.0 -20.0 .+.-300 0.0 0.. N or +55.0 550-55. +55.0-55.0 N A F+20.u -0 50.0-55.0 .. -. N A N A11 OXO . -20.0OX . N AOXXO 149 +55.0 0 +55.0 -550 . 0 . N A OF CONTENTS DESCRIPTION AddelduntoHll�! RBYielredBY - l>ffie r ,. ;e & ScALEN.T.S. 7 owO. BY: SWS CHK. ft KURT BALTHAZOR owAwwc No.: FLORIDA P.E. DWG-MA-FLO211-1 f56533 SHEET I OF 3 S SEE DETA .c. 3' 'f' #8 x 2" #10 x 5/8" #8 x 2" #10 x 518" #10 x 1" #10 x 2-1/2" #10 x 1" #10 x 5/8" ETAIL '.'D" DETAIL "C" W U a SEE J 0 w IK 0 2 .41 jf6 X Z" DETAIL "E" ASTRAGAL ATTACH ASTRAGAL RETAINER BOLT STRIKE PLATE TO FRAME AS SHOWN. 1 1 175"mA;Qr--3� 0.9621 1.437'P�=p T T T INSWING THRESHOLD BUMPER O/S THRESHOLD T4 OZS THRESHOLD i 182'ff��7m 1 1.75" aDil1.047" 1 1.437"T e TT ERIES 0/S THRESHOLD HIGH DAM O/S THRESHOLD HP O/S THRESHOLD I.I N v EE DETAIL i ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH FOR A 1.375" THROW DETAIL "F" ASTRAGA HOT MELT EUSTOMER---,., #6 X 1-1/2' PHS L HOT MELT n'•,�y y 1/2' BITE ELASTOMER '!•y,� . FxIE61QS ^ ' 1NTEEBIQE TYPICAL GLAZING DETAIL NON -IMPACT GLASS AftAmloWU mt, . Dft* I R e oWM BY. SWS CHK. BY. .0211-17 OF 3 SEE DETAIL "C" SHT. 2 FTACHMENT DETAIL ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY ROBERTO LOMAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3/4". J— 3' W �r U a SEE DETAIL } "D" SHT. 2 J aOf 0 W O a G e 3" 1,25' MIN •. t 0..25" SHIM CL —I I— mow: :a- TYPICAL MASONRY ANCHOR INSTALLATION THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4". WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. HARDWARE SCHEDUL 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. 2. 4" X 4" FULL MORTISE BUTT HINGES. 1"X1/2" CORRUGATED #10X2" WOOD SCREW 3" FROM EACH END 6" FROM EACH END AND 7" OC AND 12" OC ALAT& CAULK ALA& I CAULK I I CL •; COMBINATION WOOD COMBINATION WOOD 1MIN"� MULLION (BOXED) MULLION (BOXED) MAX" (3)) J�10X2-1/2" SHIM WO D SCREWS CL -II EACH END I _ TYPICAL WOOD BUCK ANCHOR INSTALLATION INTEGRAL WOOD MULLION (CHS) � - U p(D O or ti O _U 4= ti Lo U^ y L J �S AQderdumtoNAhl . DATE. 5 26/1 i ar SCALE N.T.S. On. BY. SWS ORK. 6Y. OF