Loading...
HomeMy WebLinkAboutGenerac info20/22/24 kW GENERACq0 GUARDIAN® SERIES Residential Standby Generators INCLUDES: Standby Power Rating 0007038 1, GU0W7039A, GW7038.3, 13007039.3 (Auminum - Bisque( - 20 kW 80 Hz • True Power'" Electrical Technology GLY170422, 0007043 2, G007042 3 G0070433 (Aluminum Bisque) 22 kW W Hz G007209-0. G007210-0 (Aluminum Bisque) 24 kW e0 H7 • Two-line multilingual digital LCD Evolution' controller (English/Spanish/French/PoOuguese) • 200 amp service rated transfer switch available • Electronic governor • Standard WI-Fi® connectivity • System status & maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a structure.' 'Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. https.Ilassets.swri. orgllibraryIDirectofyOlLisledProductsl Conshuctionlndustry1973_DoC 204_13204-01-01_Rev9.pdt FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the head of Gen- eac's success in providing the most reliable generators possible. Generac's G- Force engine lineup offers added peace of mind and reliability for when It's needed the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY O MOBILE LINKS CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smanphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, Identify, and proactive service. With Mobile Link, users are taken care of before the next power outage. Q GENERAC — — Et4 �or C®US Qvir-+�-T�. Note: CETL wCUL certification only applies to unbundled units and units packaged With limited circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state -of -the -ad power maximizing regulation system is standard on all Generic mod- els. It provides optimized FAST RESPONSE to changing load conditions and MA)O- MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Geneac's extensive dealer network provides pads and service know-how for the entire unit, from the engine to the small- est electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. O PWRVIEW" TRANSFER SWITCH: The Generic PWRview Automatic Transfer Switch integrates the PWRview energy monitor to provide real -lime energy con- sumption data that can help lower a home's electricity bill. Using a convenient mobile app, homeowners can access energy usage and alert information while under utility power or generator power. The PWRview energy monitor is a simple to use and low cost tool which helps save money over the life of the generator. Included with model G007210-0. "' GENERAC ,''4 �1 BEN___ PROMISE ®^� O v� PWR GENERAL" 20/22/24 kW Features and Benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low ail pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±f % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (If applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 311 Can be Installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. PWRview Transfer Switch (If applicable) • PWRview energy monitor Energy usage at -a -glance. • Ability to view real-time energy consumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy Intelligence and insights. Evolution" Controls • AUTO/MANUAL/OFF illuminated buttons • Two-line multilingual LCD • Sealed, raised buttons • Utility voltage sensing • Generator voltage sensing • Utility interrupt delay • Engine warm-up • Engine cool -down • Programmable exercise • Smart battery charger • Main line circuit breaker • Electronic governor Selects the operating mode and provides easy, at -a -glance status indication in any condition. Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. Smooth, wealher-resistant user interface for programming and operations. Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. Constantly monitors generator voltage to verity the cleanest power delivered to the home. Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Verifies engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minule. Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Protects generator from overload. Maintains constant 60 Hz frequency. GENERAC 20/22/24 kW Features and Benefits Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. Installation System • 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity (WI-FI equipped models only) • Ability to view generator status Monitor generator with a smanphone, tablet, or computer at any time via the Mobile Link application for ' complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. 20/22/24 kW OENERACw Specifications Generator Model G001038-1 G007042-2 G007038-3 G007D42-3 G007209-0 G007039-1 G007043-2 G007039-3 GO07043-3 G007210-0 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Bated maximum continuous power capac y [LP) 20.000 Wafts` 22,000 Wafts' 20,000 Wags' 22,000 Wads' 24,000 Wafts' Rated maximum continuous power capacity ING) 18,000 Wans' 19,500 Wans' 18.000 Walls, 19,500 Watts' 21.000 Wads' Batedvodage 240 Bated maximum continuous load current- 240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 Total Harmonic Distortion Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100amp 100 amp Phase 1 Number of rotor poles 2 Bated AC frequency 60 Hz Power factor 1.0 Battery requirement (not included) 12Volts, Group 26R 540 CCA minimum or Group 35AGM 65D CCA minimum Unit might (to /kg) 448/203 466/211 436/198 445/202 455/206 Dimensions (Lx Wx H) in/ can 48 x 25IT29/ 121.9 x 63.5 x 73.7 Sound output in cl at 23 it (7 m) with generator operating at normal Ind 67 67 67 67 67 Sound output in dB(A)at 23it(7 m) with generator in Quiet -Tel In -speed exercise made" 55 57 55 57 57 Exercise duration 5 min Engine Engine type GENEBAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/ cast In sleeve Valve arrangement Overhead valve Ignition system Solid-state w/ magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VOC Oil capacity including filter Approx. 1.9 qt/ 1.8 L Operating rpm 3,600 Fuel consumption Natural gas fil lr (m'/hr) 1/2 Load 204 (5.78) 228 (6.46) 164 (4.64) 203 (5.75) Full Load 301 (8.52) 327 (9.26) 287 (8.13) 306 (8.66) Liquid propane ll (gat/hr) RArl 1/2 Load 87 (2.37)18.991 92 (2.53)19.571 86 (2.36) (8.951 92 (2.53)19.571 Full Load 130 (3.56) [13.48] 142 (3.90) (14.771 136 (3.74) [14.15] 142 (3.90)114.771 Nate: Fuel pipe must be slzed far lull load. Required duel pressure to generator fuel inlet at all load ranges - 3.5-7 in water column (0.87-1,74 Wall for NG, 10-12 in water win= (2.49-2.99 kPa) for LP gas. For BTU content, multiply fta hr x 2500 (LP) or ftaIn x I ODD INS). For Megaloule consent, multiply m3ft x 93.15 (LP) or ma/Tr x 37.26 (NG). Two-line plain text multilingual LCD Simple user interface for ease at operation. Mode buttons: AUTO Aulmnztic star) on utility hilme. Well BI-weeldy, or Monthly selectable exerciser. MANUAL Stan with starter control, unit slays on. If utility tails, Iransler to load lakes place. OFF Slaps unit. Power Is removed. Control and charger still operate. Ready to RuniMaintenance messages Standard Engine not hours Indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Unity Voltage Loss/Return to Niliyadjustable (brownout selling) From 140-171 V/ 19DO6 V Future Set Capable Exerciser/Exercise Set Error warning Standard BurVAlamyMarmeranw lags 50 events each Engine star sequence Cyclic annual 16 sec on. 7 rest (90 sec maximum duration). Starter lock) Starter cannot re-engage until 5 sec after englne has slopped. Smart Battery Charger Standard Charger Fault/Missuff AC warning Standard Low Bagery/Battery Problem Protection and Gal Condition indication Standard Actual Voltage Regulation with Over and Under Voltage Protector Standard Under-Frequency/Overfoad/Slepper Overcurreni Protection Standard Safely Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/0uerspeed (p 72 HzYrpm Sense toss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Inconed Wiring protection Standard Common external fault capability Standard Feld collectible Nmware Standard "Swnd levels are taken from the hand of the generator. Sound levels taken from other sides of the generator may be higher depending o inslallatl)n parameters. Rating de0rridons - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. WI ratings in accordance with BS5514. IS03046 and DIN6271).' Maximum Hlowll amps and current are subject to and Ihnited by such factors as fuel BTLVmegalwle content, ambient temperature, altitude. engine power and condition eto. Maximum power decreases approximately 3.5%far each 1,000 it (304 8 m) above sea lentil; and also will decrease approximately 1%lor each 1O'F (6'C) above 60'F (16'Ck 20/22/24 kW Service Rated Automatic Transfer Switch Features • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smad Management Modules (SMMs). • Electrically operated, mechanically -held contacts for last, clean connections. • Rated for all classes of load, 100%equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMANL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Dimensions Amps 1201240, to nsition Service Rated WigJ kOpen W1 W2 in 10.5 13.5 cm 26.67 34.18 Wire Ranges Conductor Lug I Neutral Lug Ground Lug 250 MCM-#6 1 350 MCM-#6 210-#14 PWRview Automatic Transfer Switch Features • Integrated PWRview monitor provides real-time energy usage data through PWRview app. • Intelligently manages up to lour air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Strad Management Modules (SMNI • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load, 100%equipment rated, both Inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated Ior both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Heavy duty GenemC Contactor is an ETL recognized device. Dimensions 200 Amps 120/240. 1a Open Transition Service Hated Height Width H7 H2 W7 W2 Depth in 26.8 30.1 10.5 1 13.5 6.9 cm 67.95 76.43 26.67 1 34.18 1 17.5 Wire Ranges Conductor Lug Neural Lug Ground Lug 250 MCM-#6 350 MCM-#6 1 2/0-#14 GENERAC' Switch Options Model G007039-1, G0070393 (20 kW) G007043-2, G0070433 (22 kW) No. of poles 2 Current rating (amps) 200 Voltage rating (VAC) 1201240, 10 Utility voltage monitor (fixed)' -Rck-up 60% -Dropout 65% Return to U01Ity' Apo= 13 sec Exercises bi-weekly for 5 minutes' Standard E7Lor ULlisted Standard Enclosure type NEMAA)L 311 Circuit breaker protected 22,000 Lug range 250 MCM - #6 'Function of Evolution controller Exercise can be set to weekly, bi-weeldy, or momhty Model 0007210-0 (24 kW) Nv. of poles 2 Current rating (amps) 200 Voltage rating (VAC) 120/240.10 Utility voltage monitor (fixed)' -Pick-up 80% -Dropout 65% Return to Utility' Approx. 13 sec Exercises bi-weekly for 5 minutes' Standard ETL or UL listed Standard Enclosure type NEMA 311 Circuit breaker protected 22,000 Lug range 250 MGM - #6 'Function of Evolution comroner Exercise can be set to weekly, bi-weekly, or monthly 20/22/24 kW Model # Product G005819.0 26R Wet Cell Battery G007101-0 Battery Pad Warmer G007102.0 Oil Warmer 6007103-1 Breather Warmer G005621-0 Auxiliary Transfer Switch Contact Kit G007027-0 - Bisque Fascia Base Wrap Kit (Standard on 22 kW) G005703-0 - Bisque Touch -Up Paint Of G006485-0 Scheduled Maintenance Kit G007005-0 Wl-Fi LP Tank Fuel Level Monitor G007000-0(50 amp) Smart Management Module G007006-0 (100 amp) G007169-0 - 4G LTE Mobile Link® Cellular G007170-0-WI-Ill Accessories Ethernet G007220-0 - Bisque Base Plug Kit Model UPC G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 G007209.0 696471071511 G007210-0 696471078220 GENERAC' GENERAC' Available Accessories Oescriptlon Every standby generator requires a battery to start the system. Generac otters the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPae). Pad wanner rests under the battery. Recommended for use it temperature regularly falls below 0 °F (-18 °C). (Not nec- essary for use with AGM -style batteries). Oil warmer slips directly over the all filter. Recommended for use 8 temperature regularly falls below 0 °F (-18 *Q. Breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be needed. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air-cooled generators. This otters a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lilting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator (oil not Included). The WI-R enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure. Sta- tus alerts are available through a free application to nobly users when the LP tank Is In need of a refill. Smart Management Modules (SMM) are used to optimize the performance of a standby generator. it manages large elec- trical loads upon startup and sheds them to aid In recovery when overloaded. In many cases, using SMM's can reduce the overall size and cost of the system. The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world, using a smart phone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Us- ers can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. Base plugs snap into the lifting holes on the base of air-cooled home standby generators. This otters a sleek, contoured appearance, as well as offers protection from rodents and insects by covering the lining holes located in the base. KB contains four plugs, sufficient for use on a single air-cooled home standby generator. LEFT 9IOE VIEW Dimensions & UPCs FRONT MEW Olmenumssh mne apgmomNe.Sx inGallNkn rnmial IorexLG dYllelleeiem. 00 NOT USE THESE DIMENSIONS Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, W153189 • generac.com 02020 Generac Poem Systems, Inc. M BUMS lesms0. M sm Pions are sublecl to clangs vMiout mike. Psi No. ADDm937814 Rev. A 07/1520M Automatic Transfer Switches 06NERAC PWR Description GENERACa MvieWlrm Automatic Transfer Switch 200 Amps, Single Phase Model: RXEMW200A3 OUR Js Q Intertek =""'•" The Generac PWRview Automatic Transfer Switch Integrates the PWRview monitor to provide real-time energy consumption data that can help lower a home's electricity bill. Through the convenient mobile app, a homeowner can access their energy usage and alert Information while under utility power or generator power. The PWRview energy monitor Is a simple to use and low cost tool that helps save money over the fife of the generator. The 200 amp, open transition transfer switch is compatible with single-phase generators having either an Evolution— or Nexus- Controller. Standard Features Service Rated Generac Automatic Transfer Switches are housed In an aluminum NEMA Type 3R enclosure, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is an ETL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. The integrated PWRview monitor provides real-time energy usage data through the PWRview app. All transfer switches are covered by a 5 year limited warranty. Load Management Technology Through the use of the integrated Smart A/C Module (SACM), these switches have the capability to manage up to four individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with external Smart Management Modules (SMM), a total of eight more loads can be managed, providing the most installation efficient power management options available. ♦ fSt) 900�: 2008 200 Amps, Single Phase Functions All timing and sensing functions originate in the generator controller. GENERAC PWRview Automatic Transfer Switch Utility Voltage Drop -out <65% Timer to Generator Start 5 Second Factory Set, Adjustable Between 2 -1,500 Seconds by a Qualified Dealer* Engine Wannup Delay 5 Seconds Standby Voltage Sensor 65% for 5 Seconds Utility Voltage Pickup >80% Re -transfer Time Delay 15 Seconds Engine Cooldown Timer 60 Seconds Exerciser Nexus":12 Minutes Weekly Evolution—: 5 to 12 Minutes Adjustable, Weekly/Bi-weekly/Monthly The Transfer Switch can be Operated Manually Without Power Applied When used In conjunction with units utilizing Evolution- controls Specifications Amps 200 Voltage 120/240,1e Load transition type (automatic) Open transition service rated Enclosure type NEMA Type 3R Compliance ETL Withstand rating (amps) 22,000 Lug range 250 MCM - #6 Dimensions, Weight, and Wire Ranges Dimensions and Weight Height (iNcm) H1 26.8 / 67.95 H2 30.1 / 76.43 Width (in/cm) W1 10.5/26.67 W2 13.5/34.18 Depth (In/cm) 6.9 / 17.5 Weight (lbs/kg) 39.0 / 17.7 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250MCM-#6 350MCM-#6 210-#14 DE H GENERAC Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02020 Genmc Power Systems, Im. Ae rig%reMMM AN s ificam are subied m C=ge w W notice. Pan No. A0000380921 ere C 07/22/2020