HomeMy WebLinkAboutProduct Approval; Siding Panel Walls7/27/2020 Florida Building Code Online
Professional y'1 , 1
BCIS Home I Login User Registration I Hot Topics I Submit Surcharge Stats & Facts I Publications I Contact Us I BCIS Site Map' I Links I Search I
lWda
„ft
k r> r
Product Approval
D _ LSER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
• FL # FL9190-R8
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
781
LP Building Products
414 Union Street - Bank of America Plaza
Suite 2000
Nashville, TN 37219
(352)425-7457
cw.macomber@lpcorp.com ]� y/I
CW Macomber
cw.macomber@lpcorp.com
CW Macomber
5712 SW 40th Place
Ocalo, FL 34474
(352)425-7457
cw.macomber@lpcorp.com
CW Macomber
5712 SW 40th Place
Ocala, FL 34474
(352) 425-7457
cw.macomber@lpcorp.com
Panel Walls
Siding
REVIEWED
CODE COMP NCE
ST. LUCIE COUNTY
EOCC
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Do Kim, P.E.
Evaluation Report File Copy
Florida License PE-49497
Quality Assurance Entity APA - The Engineered Wood Association
Quality Assurance Contract Expiration Date 12/31/2030
Validated By James L. Buckner, P.E. @ CBUCK Engineering
Validation Checklist - Hardcopy Received
Certificate of Independence FL9190 R8 COI LP Certificate of Indeoendence.1df
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL9190 R8 Equiv equivalency of standard form.pdd
Sections from the Code
1405
https://www.floridabuilding.org/pr/pr app d.aspx?param=wGEVXQwtDquJPW%2b4UtPl LM%a2fVA7w4rtSEaOzuzggD%2bzA%3d
1/3
7/27/2020
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Florida Building Code Online
1604.3.1
1609.1
1616.3.1
1626.1
2304.6
Method 2 Option B
12/13/2019
12/16/2019
12/19/2019
02/11/i020
FL # IModel, Number or Name Description
9190.1 LP SmartSide 38 Series Strand Vertical siding for board & batten applications.
Substrate Vertical Siding
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL9190 R8 II Fastener Table MASTER 12-19.pdf
Approved for use outside HVHZ: Yes FL9190 R8 II TN 028 Vertical Siding 11-13-19.pdf
Impact Resistant: No Verified By: APA - The Engineered Wood Association
Design Pressure: N/A Created by Independent, Third Party: Yes
Other: Refer to Evaluation Report. Product is not impact Evaluation Reports
resistant. In HVHZ, must be used in conjunction with approved FL9190 R8 AE Evaluation Report of LP Sidina 9190-118-
impact resistant product except for uninhabitable structures 2017.pdf
such as sheds. Created by Independent Third Party: Yes
9190.2 LP SmartSide Cedar Shake Lap
Siding
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: Refer to Evaluation Report. Product is not impact
resistant. In HVHZ, must be used in conjunction with approved
impact resistant product except for uninhabitable structures
such as sheds.
9190.3 I LP SmartSide Fiber Substrate Bold
Profile Lap Siding
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: Refer to Evaluation Report. Product is not impact
resistant. In HVHZ, must be used in conjunction with approved
impact resistant product except for uninhabitable structures
such as sheds.
9190.4 I LP SmartSide Fiber Substrate Lap
and Panel Siding
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: Refer to Evaluation Report for Panel Siding over SIP
installation detail. Product is not impact resistant. In HVHZ,
must be used in conjunction with approved impact resistant
product except for uninhabitable structures such as sheds.
Architectural Collection Cedar Shake 76 Series Lap Siding
Installation Instructions
FL9190 R8 II ESR-3090 6-19 MASTER.pdf
FL9190 R8 II LPZB0507-Cedar Shakes -Lap (6-14)_pdf
Verified By: APA - The Engineered Wood Association
Created by Independent Third Party: Yes
Evaluation Reports
FL9190 RB AE Evaluation Report of LP Siding 9190-118-
2017.0f
Created by Independent Third Party: Yes
Architectural Collection Primed Bold Profile 120 Series Lap
Siding (D 5,T4, D 8,T5, Q4 )
Installation Instructions
FL9190 R8 II ESR-3090 6-19 MASTER.pdf
FL9190 R8 II LPZB0504-Architectural Collection -
Bold Profile -Lap (1-14)_pdf
Verified By: APA - The Engineered Wood Association
Created by Independent Third Party: Yes
Evaluation Reports
FL9190 R8 AE Evaluation Report of LP Siding 9190-118-
2017. pdf
Created by Independent Third Party: Yes
Foundations 76 Series Primed Lap Siding. Architectural
Collection 76 Series Primed Colonial and 120 Series Primed
Self -aligning Lap Siding.
Installation Instructions
FL9190 R8 II ESR-3090 6-19 MASTER.pdf
FL9190 R8 II LPZBO510 - Foundations and Architectural
Collection - Lap.pdf
FL9190 R8 II LPZBO511 - Foundations and Architectural
Collection - Panel.pdf
Verified By: APA - The Engineered Wood Association
Created by Independent Third Party: Yes
Evaluation Reports
FL9190 R8 AE Evaluation Report of LP Siding 9190-118-
2017.pdf
Created by Independent Third Party: Yes
9190.5 LP SmartSide Perfection Shingle Fiber substrate lap siding.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL9190 R8 II ESR-3090 6-19 MASTER.pdf
https://www.floridabuilding.org/pr/pr app_df.aspx?param=wGEVXQwtDquJPW%2b4UtPl LM%2fVA7w4rtSEaOzuzggD%2bzA%3d 213
7/27/2020
Florida Building Code Online
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: Refer to Evaluation Report. Product is not impact
resistant. In HVHZ, must be used in conjunction with approved
impact resistant product except for uninhabitable structures
such as sheds.
9190.6 I LP SmartSide Strand Substrate Lap
and Panel Siding
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: Refer to Evaluation Report for Panel Siding over SIP
installation detail. Product is not impact resistant. In HVHZ,
must be used in conjunction with approved impact resistant
product except for uninhabitable structures such as sheds.
FL9190 R8 II LP SS Perfection Shingle 11-19 MASTER.pdf
Verified By: APA - The Engineered Wood Association
Created by Independent Third Party: Yes
Evaluation Reports
FL9190 R8 AE Evaluation Report of LP Siding 9190-R8-
2017.Ddf
Created by Independent Third Party: Yes
Precision Series 38 and 76 Series Primed Lap Siding. Precision
38,76,190 Series Primed Panel Siding including Silvertech &
Smartfinish.
Installation Instructions
FL9190 R8 II Fastener Table MASTER 12-19.pdf
FL9190 R8 II LPZB0512-Strand Panel App Inst 2-18.pdf
FL9190 R8 II LPZB0515-Strand Lap 6-19.pdf
Verified By: APA - The Engineered Wood Association
Created by Independent Third Party: Yes
Evaluation Reports
FL9190 R8 AE Evaluation Report of LP Siding 9190-118-
2017.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Coovright 2007-2013 State of Florida.:: Privacy 211ttment :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
® ® ® ectaiE
.1 .0
scizuritym FTitics
https://www.floddabuilding.org/prlpr app_dU.aspx?param=wGEVXQwtDquJPW%2b4UtPl LM%2fVA7w4rtSEaOzuzggD%2bzA%3d 3/3
�p SmartSide@
TRIM & SIDING
At the time of manufacture, siding meets or exceeds the per-
formance standards set forth in [CC -ES AC321 and has achieved
code recognition under ESR-1301, CCMC 11826-L, APA recognition
under PR-N124, and HUD recognition under HUD-MR-1318c. For
copies of Product Approvals go online at https://Ipcorp.com/
resources/product-literature/ or call LP Customer Support at
1-800-648-6893.
• Minimum 6 inch (152 mm) clearance must be maintained
between siding and finish grade.
• Siding applied adjacent to porches, patios, walks, etc. must have
a clearance of at least 1 inch (25 mm) above any surface.
• Minimum 1 inch (25 mm) clearance at intersection with roof line.
• Apply siding in a manner that prevents moisture intrusion and
water buildup.
• All wood substrate that is exposed to the weather must be
sealed in a manner that prevents moisture intrusion and water
build up.
- Seal ALL exposed cuts of siding and trim. Field spray
applied coatings on cuts are not recommended.
- Sealing can be accomplished by applying a coating or
sealant according to the manufacturer's requirements.
- Butt joints that are covered with joint molding, sealant
orfactory prefinished end, are considered sealed from the
weather.
• See Alternate Fastening Options for fastening lap siding to SIP,
ICF and Steel Frame assemblies.
• DO NOT USE STAPLES.
• SIDING MUST NOT BE INDIRECT CONTACT WITH MASONRY,
CONCRETE, BRICK, STONE, STUCCO OR MORTAR.
• Store off the ground well supported, on a flat surface, under a
roof or separate waterproof covering.
• Keep siding clean and dry. Inspect prior to application
• 38 Series Strand Substrate lap may be installed on studs
spaced a maximum of 16 inches (406 mm) o.c.
• See Alternate Fastening Options for fastening 38 Series Strand
Substrate 6 inch (152 mm) and 8 inch (203 mm) lap on studs
spaced a maximum of 24 inches (610 mm) o.c.
• 75 Series Strand Substrate lap may be installed on studs
spaced a maximum of 24 inches (610 mm) o.c.
38 AND 76 SERIES STRAND SUBSTRATE
SMOOTH FINISH OR CEDAR TEXTURE
PRIMED LAP SIDING
For installations over masonry or concrete walls, the wall
shall be furred out and open at the top and bottom of the wall
to allow for convective ventilation between framing spaced
16 inches (406 mm) o.c. The framing shall be of adequate
thickness to accept 1-1/2 inches (38 mm) of nail penetration. A
properly installed breathable water-resistant barrier is required
between the siding and masonry or concrete walls.
• Moisture control and moisture vapor control are critical
elements of proper housing design. Check your local building
codes for application procedures for handling moisture and
water vapor in your area.
• When using wet blown cellulose insulation, the insulation
must not be in direct contact with the siding and it must be
allowed to dry a minimum of 24 hours or longer if specified by
the insulation manufacturer.
• As with all wood products, do not apply engineered wood
siding to a structure having excessive moisture conditions such
as drying concrete, plaster or wet blown cellulose insulation. If
such conditions exist, the building should be well ventilated to
allow it to dry priorto the application of the siding.
• Siding must not be applied to green or crooked structural
framing members. Do not apply siding over rain -soaked or
buckled sheathing materials.
• Gutters are recommended for control of roof water run off.
• A properly installed breathable water-resistant barrier is
required behind the siding. Consult your local building code
for details.
• LP will assume no responsibility for water penetration.
• Seal gaps with a high -quality, non -hardening, paintable
sealant.
• Follow the sealant manufacturer's instructions for application.
• Use a high -quality exterior sealant meeting the ASTM C920,
minimum Class 2S sealant.
• All openings must be properly sealed or flashed in a manner that
prevents moisture intrusion or buildup. Several examples that
accomplish this are shown on the following pages.
APPLICATION INSTRUCTIONS (CONT.)
• Install kick -out flashing to direct the water into the gutter.
• Install step flashing with minimum 4 inch (102 mm) upper leg.
• Properly integrate flashing with the secondary water-resistant
barrier. Use housewrap, flashing tape, Z-flashing, or other
items as needed to maintain the counterflashing principle.
• DO NOT extend the siding or trim into the kick -out flashing or gutter.
• Maintain a clearance between the end of the gutter and the
adjoining wall to allow for proper maintenance of the siding.
• Seal ALL exposed cut edges.
r
r
LP Siding
Min. T' clearance
between siding and roofing
Clean rain
gutter
For best results use exterior -quality 100% acrylic latex paint,
specially formulated for use on wood and engineered wood
substrates; oil paint is acceptable.
- Alkyd acrylic hybrid paint used as a primer is acceptable,
not as finish coat.
- DO NOT USE shake or shingle paint.
- DO NOT USE semi -transparent and transparent stain.
- DO NOT USE Vinyl -based resin formulas such as vinyl
acetate, PVA, vinyl acetate/acrylic copolymer paint.
SMOOTH FINISH Lap Siding:
• For best results use satin finish.
CEDAR TEXTURE Lap Siding:
• For best results use satin or semi -gloss finish.
PREFINISHED Lap Siding:
• Handle prefinished LP SmartSide lap siding with extreme care
during storage and application.
• Touch up any damage to finish that may occur during
application per the Prefinishers specifications.
NAILING INSTRUCTIONS
• LP SmartSide 38 Series lap siding maybe attached directly to
framing members spaced a maximum of 16 inches (406 mm) o.c.
• LP SmartSide 76 Series lap siding may be attached directlyto
framing members spaced a maximum of 24 inches (610 mm) o.c.
• Check your local building codes before starting to install siding
to confirm if wood structural panel wall sheathing is required.
• Siding butt joints should be staggered over successive courses.
• For siding installations with or without wood structural panels,
butt joints must occur over stud locations.
• Siding shall be installed with top (blind) nailing, with the nails
Do not run siding or trim inside placed 3/8 inch (10 mm) from either end and a minimum of
of the kick out flashing 3/4 inch (19 mm) from the top edge of the board. Fasteners will
be exposed on siding located immediately below window sills,
fascia boards, and horizontal trim. Fasteners below window sill
shall be spaced a maximum of 8 inch (203 mm) o.c.
• Trim should be thick enough so the lap siding does not extend
beyond the face of the trim.
• Trim and fascia must be applied in a manner that will not allow
moisture intrusion or water buildup.
• LP° SmartSide® siding is not designed and/or manufactured
to be used as trim.
- LP SmartSide trim and fascia are available in a variety of
dimensions.
• Seal all exposed surfaces, including all drip edges or where
water will hang.
• Apply finish coat as soon as possible or within 180 days of
application.
• Follow the coating manufacturer's application and maintence
instructions.
• Overlap successive courses of siding a minimum of 1 inch (2S mm).
SmartLock Lap Overlap
& Blind Fastening
Self -alit
rabbet'
T' overlap
3/4" nail
spacing
Install
SmartLock Lap
consistent with
specifications in
this document
CONDITION
CORRECTION
APPLICATION INSTRUCTIONS (CONT.)
Alternative Fastening Option over ICF Assemblies
k
Flush
(11
Visible fiber
Countersunk 1/16"-1/8"_-(
�
a
Countersunk more
than 1/8"
Paint
Apply sealant
Apply sealant and —�
re -nail
• Use minimum 8d (0.113 inch shank diameter), hot -dipped
galvanized nail.
• All exposed face nails must be caulked and sealed in a manner
that prevents moisture intrusion and water buildup.
• Penetrate structural framing or wood structural panels and
structural framing a minimum of 1-1/2 inches (38 mm).
• Nail from the center of the siding toward the ends, or from one
end to the other end. NEVER nail from the ends of the siding
toward the middle.
• Shim siding at studs as needed, to avoid drawing siding against
uneven walls. Do not overdrive nails. Nail head should seat
firmly to face of siding but not be overdriven to distort the
siding surface.
• For information on fastening LP SmartSide.products in high wind
speed areas, refer to ICC-ES Report ESR-1301 or APA PR-N124.
Alternative Fastening Option for Strand Lap Siding over Wood
Structural Panels and 24 inch (610 mm) o.c. Stud Spacing
• Limited to 6 inch (152 mm) and 8 inch (203 mm) wide lap siding.
• Wood structural panels must be a minimum 7/16 Category with an
APA Trademark that contains the consensus Standard DOC PS 2.
• 38 Series Strand Substate lap must be fastened with:
- Minimum #8 hot dip galvanized tapered head wood screw,
spaced a maximum of 12 inches (305 mm) o.c. with 1-1/2 inch
(38 mm) screw penetration into stud or...
- Minimum 6d (0.092 in. shank diameter) hot -dipped galvanized
ring shank nail, spaced a maximum of 8 inches (203 mm) o.c.
with 1-1/2 inch (38 mm) nail penetration into stud.
Alternative Fastening Options over SIP Assemblies
• Wood structural panels must be a minimum 7/16 Category with an
APA Trademark that contains the consensus standard DOC PS 2.
• 38 Series Strand Substrate lap must be fastened with:
- Minimum #8 hot dip galvanized tapered head wood screw,
spaced a maximum of 12 inches (305 mm) o.c. or...
- Minimum 6d (0.092 inch shank diameter) hot -dipped
galvanized ring shank nail, spaced a maximum of 8 inches
(203 mm) D.C.
• 76 Series Strand Substrate lap must be fastened with:
- Minimum #8 hot dip galvanized tapered head wood screw,
spaced a maximum of 16 inches (406 mm) o.c. or...
- Minimum 6d (0.092 inch shank diameter) hot -dipped
galvanized ring shank nail, spaced a maximum of 12 inches
(305 mm) D.C.
38 and 76 Series Strand Substrate Lap must be fastened with:
- Minimum #8 hot -dipped galvanized, tapered head,
self -drilling screw.
- Minimum penetration of 3/8 inch (10 mm) beyond the
thickness of the nailing flange.
- Larger screws may be required by the ICF Manufacturer
based on the following minimum withdrawal requirements.
• Minimum withdrawal value of the ICF nailing flange must be
50 lbs. with a maximum 12 inches (305 mm) o.c. screw spacing.
• Minimum withdrawal value of the ICF nailing flange must be
31 Ibs, with a maximum 6 inches (152 mm) D.C. screw spacing.
Alternative Fastening Options over Corrosion Resistant
Steel Stud Framing
• Minimum withdrawal value of the steel framing must be 50 Ibs.
Refer to the framing manufacturer's evaluation report.
38 Series Strand Substrate lap must be fastened with:
- Stud spacing a maximum spacing of 16 inches (406 mm) o.c.
- Minimum #8 hot -dipped galvanized, tapered head,
self -drilling screw.
- Minimum of 5 threads beyond the combined thickness of
the siding and steel stud framing.
- Minimum steel framing thickness of 0.032 inch (8 mm) or
20 gauge.
76 Series Strand Substrate lap must be fastened with:
- Stud spacing a maximum spacing of 24 inches (610 mm) D.C.
- Minimum #8 hot -dipped galvanized, tapered head,
self -drilling screw.
- Minimum of 5 threads beyond the combined thickness of
the siding and steel stud framing.
- Minimum steel framing thickness of 0.032 inch (8 mm) or
20 gauge.
CAUTION
• Do not force siding into place.
• DO NOT USE STAPLES.
• Climb cut the surface of the siding such that the rotation of the
blade cuts downward on the primed or prefinished surface.
• Where siding butts window trim, door casings and masonry,
etc. leave a 3/16 inch (S mm) gap and seal.
Insulated Sheathings
LP SmartSide lap sidings may be installed over low -compression,
rigid foam insulation sheathing or exterior gypsum. The following
precautions must be followed:
• Adequate bracing of the wall in accordance with the
International Building Codes or other ruling building codes is
required. -
• For rigid foam insulation sheathing up to 1 inch (25 mm) thick,
siding may be nailed directly to the foam sheathing unless
a drainage plane is required by the local building code. Nail
length must be increased to ensure a minimum 1-1/2 inch
(38 mm) fastener penetration into the structural framing.
APPLICATION INSTRUCTIONS (CONT.)
For rigid foam insulation sheathing greater than 1 inch (25 mm),
a minimum 1-1/2 inches (38 mm) thick by 3-1/2 inches (89 mm)
wide vertical strap or furring strip must be installed over the
sheathing to provide a solid level nailing base for the siding.
The strapping must be securely fastened to structural framing
spaced no greater than 16 inches (406 mm) o.c. with a mini-
mum nail penetration of 1-1/2 inches (38 mm) and a maximum
nail spacing no greater than the width of the siding.
Louisiana-Pacific will assume no responsibility for any damage or
condition arising from the use of rigid foam insulation sheathing
or exterior gypsum.
OVERLAP, CLEARANCE & NAILING SPACE
Min.1"
overlap
Extend siding
below plate
Min. 6"
finish grade
clearance
Figure 2
Nail min. 3/4" from top
and 3/8" from edge I
,Space nail min.
3/4" from top
Sheathing,
if required
Siding must not
contact masonry
Figure 4
Trim
Min. 3/16" gap
4" min. flashing Paint bottom
edge of siding
111min. clearance
from roofing
LP Strand Substrate Lap Siding may also be installed in compliance with
Breathable Category 8140- Exterior wall siding and sheathing for Wildland Unban
water-resistant barrier Interface (WUI) applications atop LP FlameBlock sheathing. Refer to
FlameBlocl< installation instructions and product data sheets. All LP lap
sidings may be installed as exterior siding in Wildland Urban Interface
(WUI) applications installed over one layer 5/8" (16 mm) Type X gypsum
sheathing applied behind the exterior covering or cladding on the exterior
side of the framing. They may also be installed over the exterior portion
of a 1-hour fire -resistive exterior wall assembly designed for exterior fire
exposure including assemblies using the gypsum panel and sheathing
products listed in the Gypsum Association Fire Resistance Design Manual.
• Butt joints must occur over studs.
• A minimum 3/16 inch (5 mm) gap is required at ALL butt joints.
• If joint caulking option is selected, seal all gaps at butt joints
with a high -quality exterior sealant meeting the ASTM C920,
minimum Class 25 sealant.
• If joint moulding option is selected, add the thickness of the
web to the gap allowing a net 3/16 inch (5 mm) space for expansion.
• If siding is prefinished by a Preferred Prefinisher, gap does not
require sealant or joint moulding when backed with minimum
4 inch (102 mm) wide flashing and the ends of the siding are
factory finished.
The Louisiana-Pacific Corporation ("LP") LP SmartSide Siding (the
"Products") limited warranty (the "Warranty") applies only to structures on
which the Products have been applied, finished and maintained in accordance
with the published application, finishing and maintenance instructions
in effect at the time of application. The failure to follow such application,
finishing or maintenance instructions will void the Warranty as to the portion
of the Products affected by the variance (the "Affected Products").
LP assumes no liability for any loss or damage sustained by the Affected
Products and is expressly released by the purchaser or owner from any such
loss or liability.
Any modification of the Warranty's application, finishing or maintenance
requirements is void unless approved in writing by LP prior to application.
For a copy of the warranty or for installation and technical
support, visit the LP SmartSide product support Web site at:
www.lpsmartside.com
or for additional support call 800-648-6893.
WARRANTY REMEDIES ARE NOT AVAILABLE IF
REQUIREMENTS ARE NOT FOLLOWED.
A WARNING: Drilling, sawing, sanding or machining wood
products can expose you to wood dust, a substance known to the
State of California to cause cancer. Avoid inhaling wood dust or
use a dust mask or other safeguards for personal protection. For
more information go to www.P6SWarnings.ca.gov/wood.
SmartSide®
LP
TRIM & SIDING
02019 Louisiana-Pacific Corporation. All rights reserved. LP and SmartSide are registered trademarks of
Louisiana-Pacific Corporation. Printed in U.S.A.
NOTE: Louisiana-Pacific Corporation periodically updates and revises its product Information.
To verify -that this version Is.current, cali a00-450-6106.
LPZB051S 6/19
APPLICATION INSTRUCTIONS (CONT.)
Figure 3
Over Openings Alternate Butt Joint Treatments
Inside Corner Outside Corner
Detail Detail