Loading...
HomeMy WebLinkAboutProduct Approval; Siding Panel Walls7/27/2020 Florida Building Code Online Professional y'1 , 1 BCIS Home I Login User Registration I Hot Topics I Submit Surcharge Stats & Facts I Publications I Contact Us I BCIS Site Map' I Links I Search I lWda „ft k r> r Product Approval D _ LSER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail • FL # FL9190-R8 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method 781 LP Building Products 414 Union Street - Bank of America Plaza Suite 2000 Nashville, TN 37219 (352)425-7457 cw.macomber@lpcorp.com ]� y/I CW Macomber cw.macomber@lpcorp.com CW Macomber 5712 SW 40th Place Ocalo, FL 34474 (352)425-7457 cw.macomber@lpcorp.com CW Macomber 5712 SW 40th Place Ocala, FL 34474 (352) 425-7457 cw.macomber@lpcorp.com Panel Walls Siding REVIEWED CODE COMP NCE ST. LUCIE COUNTY EOCC Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Do Kim, P.E. Evaluation Report File Copy Florida License PE-49497 Quality Assurance Entity APA - The Engineered Wood Association Quality Assurance Contract Expiration Date 12/31/2030 Validated By James L. Buckner, P.E. @ CBUCK Engineering Validation Checklist - Hardcopy Received Certificate of Independence FL9190 R8 COI LP Certificate of Indeoendence.1df Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL9190 R8 Equiv equivalency of standard form.pdd Sections from the Code 1405 https://www.floridabuilding.org/pr/pr app d.aspx?param=wGEVXQwtDquJPW%2b4UtPl LM%a2fVA7w4rtSEaOzuzggD%2bzA%3d 1/3 7/27/2020 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Florida Building Code Online 1604.3.1 1609.1 1616.3.1 1626.1 2304.6 Method 2 Option B 12/13/2019 12/16/2019 12/19/2019 02/11/i020 FL # IModel, Number or Name Description 9190.1 LP SmartSide 38 Series Strand Vertical siding for board & batten applications. Substrate Vertical Siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL9190 R8 II Fastener Table MASTER 12-19.pdf Approved for use outside HVHZ: Yes FL9190 R8 II TN 028 Vertical Siding 11-13-19.pdf Impact Resistant: No Verified By: APA - The Engineered Wood Association Design Pressure: N/A Created by Independent, Third Party: Yes Other: Refer to Evaluation Report. Product is not impact Evaluation Reports resistant. In HVHZ, must be used in conjunction with approved FL9190 R8 AE Evaluation Report of LP Sidina 9190-118- impact resistant product except for uninhabitable structures 2017.pdf such as sheds. Created by Independent Third Party: Yes 9190.2 LP SmartSide Cedar Shake Lap Siding Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Refer to Evaluation Report. Product is not impact resistant. In HVHZ, must be used in conjunction with approved impact resistant product except for uninhabitable structures such as sheds. 9190.3 I LP SmartSide Fiber Substrate Bold Profile Lap Siding Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Refer to Evaluation Report. Product is not impact resistant. In HVHZ, must be used in conjunction with approved impact resistant product except for uninhabitable structures such as sheds. 9190.4 I LP SmartSide Fiber Substrate Lap and Panel Siding Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Refer to Evaluation Report for Panel Siding over SIP installation detail. Product is not impact resistant. In HVHZ, must be used in conjunction with approved impact resistant product except for uninhabitable structures such as sheds. Architectural Collection Cedar Shake 76 Series Lap Siding Installation Instructions FL9190 R8 II ESR-3090 6-19 MASTER.pdf FL9190 R8 II LPZB0507-Cedar Shakes -Lap (6-14)_pdf Verified By: APA - The Engineered Wood Association Created by Independent Third Party: Yes Evaluation Reports FL9190 RB AE Evaluation Report of LP Siding 9190-118- 2017.0f Created by Independent Third Party: Yes Architectural Collection Primed Bold Profile 120 Series Lap Siding (D 5,T4, D 8,T5, Q4 ) Installation Instructions FL9190 R8 II ESR-3090 6-19 MASTER.pdf FL9190 R8 II LPZB0504-Architectural Collection - Bold Profile -Lap (1-14)_pdf Verified By: APA - The Engineered Wood Association Created by Independent Third Party: Yes Evaluation Reports FL9190 R8 AE Evaluation Report of LP Siding 9190-118- 2017. pdf Created by Independent Third Party: Yes Foundations 76 Series Primed Lap Siding. Architectural Collection 76 Series Primed Colonial and 120 Series Primed Self -aligning Lap Siding. Installation Instructions FL9190 R8 II ESR-3090 6-19 MASTER.pdf FL9190 R8 II LPZBO510 - Foundations and Architectural Collection - Lap.pdf FL9190 R8 II LPZBO511 - Foundations and Architectural Collection - Panel.pdf Verified By: APA - The Engineered Wood Association Created by Independent Third Party: Yes Evaluation Reports FL9190 R8 AE Evaluation Report of LP Siding 9190-118- 2017.pdf Created by Independent Third Party: Yes 9190.5 LP SmartSide Perfection Shingle Fiber substrate lap siding. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL9190 R8 II ESR-3090 6-19 MASTER.pdf https://www.floridabuilding.org/pr/pr app_df.aspx?param=wGEVXQwtDquJPW%2b4UtPl LM%2fVA7w4rtSEaOzuzggD%2bzA%3d 213 7/27/2020 Florida Building Code Online Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Refer to Evaluation Report. Product is not impact resistant. In HVHZ, must be used in conjunction with approved impact resistant product except for uninhabitable structures such as sheds. 9190.6 I LP SmartSide Strand Substrate Lap and Panel Siding Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Refer to Evaluation Report for Panel Siding over SIP installation detail. Product is not impact resistant. In HVHZ, must be used in conjunction with approved impact resistant product except for uninhabitable structures such as sheds. FL9190 R8 II LP SS Perfection Shingle 11-19 MASTER.pdf Verified By: APA - The Engineered Wood Association Created by Independent Third Party: Yes Evaluation Reports FL9190 R8 AE Evaluation Report of LP Siding 9190-R8- 2017.Ddf Created by Independent Third Party: Yes Precision Series 38 and 76 Series Primed Lap Siding. Precision 38,76,190 Series Primed Panel Siding including Silvertech & Smartfinish. Installation Instructions FL9190 R8 II Fastener Table MASTER 12-19.pdf FL9190 R8 II LPZB0512-Strand Panel App Inst 2-18.pdf FL9190 R8 II LPZB0515-Strand Lap 6-19.pdf Verified By: APA - The Engineered Wood Association Created by Independent Third Party: Yes Evaluation Reports FL9190 R8 AE Evaluation Report of LP Siding 9190-118- 2017.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Coovright 2007-2013 State of Florida.:: Privacy 211ttment :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ® ® ectaiE .1 .0 scizuritym FTitics https://www.floddabuilding.org/prlpr app_dU.aspx?param=wGEVXQwtDquJPW%2b4UtPl LM%2fVA7w4rtSEaOzuzggD%2bzA%3d 3/3 �p SmartSide@ TRIM & SIDING At the time of manufacture, siding meets or exceeds the per- formance standards set forth in [CC -ES AC321 and has achieved code recognition under ESR-1301, CCMC 11826-L, APA recognition under PR-N124, and HUD recognition under HUD-MR-1318c. For copies of Product Approvals go online at https://Ipcorp.com/ resources/product-literature/ or call LP Customer Support at 1-800-648-6893. • Minimum 6 inch (152 mm) clearance must be maintained between siding and finish grade. • Siding applied adjacent to porches, patios, walks, etc. must have a clearance of at least 1 inch (25 mm) above any surface. • Minimum 1 inch (25 mm) clearance at intersection with roof line. • Apply siding in a manner that prevents moisture intrusion and water buildup. • All wood substrate that is exposed to the weather must be sealed in a manner that prevents moisture intrusion and water build up. - Seal ALL exposed cuts of siding and trim. Field spray applied coatings on cuts are not recommended. - Sealing can be accomplished by applying a coating or sealant according to the manufacturer's requirements. - Butt joints that are covered with joint molding, sealant orfactory prefinished end, are considered sealed from the weather. • See Alternate Fastening Options for fastening lap siding to SIP, ICF and Steel Frame assemblies. • DO NOT USE STAPLES. • SIDING MUST NOT BE INDIRECT CONTACT WITH MASONRY, CONCRETE, BRICK, STONE, STUCCO OR MORTAR. • Store off the ground well supported, on a flat surface, under a roof or separate waterproof covering. • Keep siding clean and dry. Inspect prior to application • 38 Series Strand Substrate lap may be installed on studs spaced a maximum of 16 inches (406 mm) o.c. • See Alternate Fastening Options for fastening 38 Series Strand Substrate 6 inch (152 mm) and 8 inch (203 mm) lap on studs spaced a maximum of 24 inches (610 mm) o.c. • 75 Series Strand Substrate lap may be installed on studs spaced a maximum of 24 inches (610 mm) o.c. 38 AND 76 SERIES STRAND SUBSTRATE SMOOTH FINISH OR CEDAR TEXTURE PRIMED LAP SIDING For installations over masonry or concrete walls, the wall shall be furred out and open at the top and bottom of the wall to allow for convective ventilation between framing spaced 16 inches (406 mm) o.c. The framing shall be of adequate thickness to accept 1-1/2 inches (38 mm) of nail penetration. A properly installed breathable water-resistant barrier is required between the siding and masonry or concrete walls. • Moisture control and moisture vapor control are critical elements of proper housing design. Check your local building codes for application procedures for handling moisture and water vapor in your area. • When using wet blown cellulose insulation, the insulation must not be in direct contact with the siding and it must be allowed to dry a minimum of 24 hours or longer if specified by the insulation manufacturer. • As with all wood products, do not apply engineered wood siding to a structure having excessive moisture conditions such as drying concrete, plaster or wet blown cellulose insulation. If such conditions exist, the building should be well ventilated to allow it to dry priorto the application of the siding. • Siding must not be applied to green or crooked structural framing members. Do not apply siding over rain -soaked or buckled sheathing materials. • Gutters are recommended for control of roof water run off. • A properly installed breathable water-resistant barrier is required behind the siding. Consult your local building code for details. • LP will assume no responsibility for water penetration. • Seal gaps with a high -quality, non -hardening, paintable sealant. • Follow the sealant manufacturer's instructions for application. • Use a high -quality exterior sealant meeting the ASTM C920, minimum Class 2S sealant. • All openings must be properly sealed or flashed in a manner that prevents moisture intrusion or buildup. Several examples that accomplish this are shown on the following pages. APPLICATION INSTRUCTIONS (CONT.) • Install kick -out flashing to direct the water into the gutter. • Install step flashing with minimum 4 inch (102 mm) upper leg. • Properly integrate flashing with the secondary water-resistant barrier. Use housewrap, flashing tape, Z-flashing, or other items as needed to maintain the counterflashing principle. • DO NOT extend the siding or trim into the kick -out flashing or gutter. • Maintain a clearance between the end of the gutter and the adjoining wall to allow for proper maintenance of the siding. • Seal ALL exposed cut edges. r r LP Siding Min. T' clearance between siding and roofing Clean rain gutter For best results use exterior -quality 100% acrylic latex paint, specially formulated for use on wood and engineered wood substrates; oil paint is acceptable. - Alkyd acrylic hybrid paint used as a primer is acceptable, not as finish coat. - DO NOT USE shake or shingle paint. - DO NOT USE semi -transparent and transparent stain. - DO NOT USE Vinyl -based resin formulas such as vinyl acetate, PVA, vinyl acetate/acrylic copolymer paint. SMOOTH FINISH Lap Siding: • For best results use satin finish. CEDAR TEXTURE Lap Siding: • For best results use satin or semi -gloss finish. PREFINISHED Lap Siding: • Handle prefinished LP SmartSide lap siding with extreme care during storage and application. • Touch up any damage to finish that may occur during application per the Prefinishers specifications. NAILING INSTRUCTIONS • LP SmartSide 38 Series lap siding maybe attached directly to framing members spaced a maximum of 16 inches (406 mm) o.c. • LP SmartSide 76 Series lap siding may be attached directlyto framing members spaced a maximum of 24 inches (610 mm) o.c. • Check your local building codes before starting to install siding to confirm if wood structural panel wall sheathing is required. • Siding butt joints should be staggered over successive courses. • For siding installations with or without wood structural panels, butt joints must occur over stud locations. • Siding shall be installed with top (blind) nailing, with the nails Do not run siding or trim inside placed 3/8 inch (10 mm) from either end and a minimum of of the kick out flashing 3/4 inch (19 mm) from the top edge of the board. Fasteners will be exposed on siding located immediately below window sills, fascia boards, and horizontal trim. Fasteners below window sill shall be spaced a maximum of 8 inch (203 mm) o.c. • Trim should be thick enough so the lap siding does not extend beyond the face of the trim. • Trim and fascia must be applied in a manner that will not allow moisture intrusion or water buildup. • LP° SmartSide® siding is not designed and/or manufactured to be used as trim. - LP SmartSide trim and fascia are available in a variety of dimensions. • Seal all exposed surfaces, including all drip edges or where water will hang. • Apply finish coat as soon as possible or within 180 days of application. • Follow the coating manufacturer's application and maintence instructions. • Overlap successive courses of siding a minimum of 1 inch (2S mm). SmartLock Lap Overlap & Blind Fastening Self -alit rabbet' T' overlap 3/4" nail spacing Install SmartLock Lap consistent with specifications in this document CONDITION CORRECTION APPLICATION INSTRUCTIONS (CONT.) Alternative Fastening Option over ICF Assemblies k Flush (11 Visible fiber Countersunk 1/16"-1/8"_-( � a Countersunk more than 1/8" Paint Apply sealant Apply sealant and —� re -nail • Use minimum 8d (0.113 inch shank diameter), hot -dipped galvanized nail. • All exposed face nails must be caulked and sealed in a manner that prevents moisture intrusion and water buildup. • Penetrate structural framing or wood structural panels and structural framing a minimum of 1-1/2 inches (38 mm). • Nail from the center of the siding toward the ends, or from one end to the other end. NEVER nail from the ends of the siding toward the middle. • Shim siding at studs as needed, to avoid drawing siding against uneven walls. Do not overdrive nails. Nail head should seat firmly to face of siding but not be overdriven to distort the siding surface. • For information on fastening LP SmartSide.products in high wind speed areas, refer to ICC-ES Report ESR-1301 or APA PR-N124. Alternative Fastening Option for Strand Lap Siding over Wood Structural Panels and 24 inch (610 mm) o.c. Stud Spacing • Limited to 6 inch (152 mm) and 8 inch (203 mm) wide lap siding. • Wood structural panels must be a minimum 7/16 Category with an APA Trademark that contains the consensus Standard DOC PS 2. • 38 Series Strand Substate lap must be fastened with: - Minimum #8 hot dip galvanized tapered head wood screw, spaced a maximum of 12 inches (305 mm) o.c. with 1-1/2 inch (38 mm) screw penetration into stud or... - Minimum 6d (0.092 in. shank diameter) hot -dipped galvanized ring shank nail, spaced a maximum of 8 inches (203 mm) o.c. with 1-1/2 inch (38 mm) nail penetration into stud. Alternative Fastening Options over SIP Assemblies • Wood structural panels must be a minimum 7/16 Category with an APA Trademark that contains the consensus standard DOC PS 2. • 38 Series Strand Substrate lap must be fastened with: - Minimum #8 hot dip galvanized tapered head wood screw, spaced a maximum of 12 inches (305 mm) o.c. or... - Minimum 6d (0.092 inch shank diameter) hot -dipped galvanized ring shank nail, spaced a maximum of 8 inches (203 mm) D.C. • 76 Series Strand Substrate lap must be fastened with: - Minimum #8 hot dip galvanized tapered head wood screw, spaced a maximum of 16 inches (406 mm) o.c. or... - Minimum 6d (0.092 inch shank diameter) hot -dipped galvanized ring shank nail, spaced a maximum of 12 inches (305 mm) D.C. 38 and 76 Series Strand Substrate Lap must be fastened with: - Minimum #8 hot -dipped galvanized, tapered head, self -drilling screw. - Minimum penetration of 3/8 inch (10 mm) beyond the thickness of the nailing flange. - Larger screws may be required by the ICF Manufacturer based on the following minimum withdrawal requirements. • Minimum withdrawal value of the ICF nailing flange must be 50 lbs. with a maximum 12 inches (305 mm) o.c. screw spacing. • Minimum withdrawal value of the ICF nailing flange must be 31 Ibs, with a maximum 6 inches (152 mm) D.C. screw spacing. Alternative Fastening Options over Corrosion Resistant Steel Stud Framing • Minimum withdrawal value of the steel framing must be 50 Ibs. Refer to the framing manufacturer's evaluation report. 38 Series Strand Substrate lap must be fastened with: - Stud spacing a maximum spacing of 16 inches (406 mm) o.c. - Minimum #8 hot -dipped galvanized, tapered head, self -drilling screw. - Minimum of 5 threads beyond the combined thickness of the siding and steel stud framing. - Minimum steel framing thickness of 0.032 inch (8 mm) or 20 gauge. 76 Series Strand Substrate lap must be fastened with: - Stud spacing a maximum spacing of 24 inches (610 mm) D.C. - Minimum #8 hot -dipped galvanized, tapered head, self -drilling screw. - Minimum of 5 threads beyond the combined thickness of the siding and steel stud framing. - Minimum steel framing thickness of 0.032 inch (8 mm) or 20 gauge. CAUTION • Do not force siding into place. • DO NOT USE STAPLES. • Climb cut the surface of the siding such that the rotation of the blade cuts downward on the primed or prefinished surface. • Where siding butts window trim, door casings and masonry, etc. leave a 3/16 inch (S mm) gap and seal. Insulated Sheathings LP SmartSide lap sidings may be installed over low -compression, rigid foam insulation sheathing or exterior gypsum. The following precautions must be followed: • Adequate bracing of the wall in accordance with the International Building Codes or other ruling building codes is required. - • For rigid foam insulation sheathing up to 1 inch (25 mm) thick, siding may be nailed directly to the foam sheathing unless a drainage plane is required by the local building code. Nail length must be increased to ensure a minimum 1-1/2 inch (38 mm) fastener penetration into the structural framing. APPLICATION INSTRUCTIONS (CONT.) For rigid foam insulation sheathing greater than 1 inch (25 mm), a minimum 1-1/2 inches (38 mm) thick by 3-1/2 inches (89 mm) wide vertical strap or furring strip must be installed over the sheathing to provide a solid level nailing base for the siding. The strapping must be securely fastened to structural framing spaced no greater than 16 inches (406 mm) o.c. with a mini- mum nail penetration of 1-1/2 inches (38 mm) and a maximum nail spacing no greater than the width of the siding. Louisiana-Pacific will assume no responsibility for any damage or condition arising from the use of rigid foam insulation sheathing or exterior gypsum. OVERLAP, CLEARANCE & NAILING SPACE Min.1" overlap Extend siding below plate Min. 6" finish grade clearance Figure 2 Nail min. 3/4" from top and 3/8" from edge I ,Space nail min. 3/4" from top Sheathing, if required Siding must not contact masonry Figure 4 Trim Min. 3/16" gap 4" min. flashing Paint bottom edge of siding 111min. clearance from roofing LP Strand Substrate Lap Siding may also be installed in compliance with Breathable Category 8140- Exterior wall siding and sheathing for Wildland Unban water-resistant barrier Interface (WUI) applications atop LP FlameBlock sheathing. Refer to FlameBlocl< installation instructions and product data sheets. All LP lap sidings may be installed as exterior siding in Wildland Urban Interface (WUI) applications installed over one layer 5/8" (16 mm) Type X gypsum sheathing applied behind the exterior covering or cladding on the exterior side of the framing. They may also be installed over the exterior portion of a 1-hour fire -resistive exterior wall assembly designed for exterior fire exposure including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual. • Butt joints must occur over studs. • A minimum 3/16 inch (5 mm) gap is required at ALL butt joints. • If joint caulking option is selected, seal all gaps at butt joints with a high -quality exterior sealant meeting the ASTM C920, minimum Class 25 sealant. • If joint moulding option is selected, add the thickness of the web to the gap allowing a net 3/16 inch (5 mm) space for expansion. • If siding is prefinished by a Preferred Prefinisher, gap does not require sealant or joint moulding when backed with minimum 4 inch (102 mm) wide flashing and the ends of the siding are factory finished. The Louisiana-Pacific Corporation ("LP") LP SmartSide Siding (the "Products") limited warranty (the "Warranty") applies only to structures on which the Products have been applied, finished and maintained in accordance with the published application, finishing and maintenance instructions in effect at the time of application. The failure to follow such application, finishing or maintenance instructions will void the Warranty as to the portion of the Products affected by the variance (the "Affected Products"). LP assumes no liability for any loss or damage sustained by the Affected Products and is expressly released by the purchaser or owner from any such loss or liability. Any modification of the Warranty's application, finishing or maintenance requirements is void unless approved in writing by LP prior to application. For a copy of the warranty or for installation and technical support, visit the LP SmartSide product support Web site at: www.lpsmartside.com or for additional support call 800-648-6893. WARRANTY REMEDIES ARE NOT AVAILABLE IF REQUIREMENTS ARE NOT FOLLOWED. A WARNING: Drilling, sawing, sanding or machining wood products can expose you to wood dust, a substance known to the State of California to cause cancer. Avoid inhaling wood dust or use a dust mask or other safeguards for personal protection. For more information go to www.P6SWarnings.ca.gov/wood. SmartSide® LP TRIM & SIDING 02019 Louisiana-Pacific Corporation. All rights reserved. LP and SmartSide are registered trademarks of Louisiana-Pacific Corporation. Printed in U.S.A. NOTE: Louisiana-Pacific Corporation periodically updates and revises its product Information. To verify -that this version Is.current, cali a00-450-6106. LPZB051S 6/19 APPLICATION INSTRUCTIONS (CONT.) Figure 3 Over Openings Alternate Butt Joint Treatments Inside Corner Outside Corner Detail Detail