Loading...
HomeMy WebLinkAboutProduct approvals 9/24/2020 Florida Building Code Online BCIS Home I Log In I User Registration ' Hot Topics I Submit Surcharge I Stats&Facts ( Publications Contact Us I, BCIS Site Map' I Links Search, ' Florida VON 1111111 Product Approval p� USER:Public User r Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL22363-R5 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived 0 Product Manufacturer Masonite International Address/Phone/Email 195S Powis Road West Chicago,IL 60185 (800) 663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year ASTM E1886 2005 ASTM E1996 2009 ASTM E330 2002 TAS 202 1994 { Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 01/25/2019 Date Validated 02/25/2019 https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7RoByOHRga2pQyiOfQKBIkVjnFjOV8Q%3d%3d 1/4 9/24/2020 Florida Building Code Online Date Pending FBC Approval Date Approved 03/05/2019 Summary of Products FL# Model, Number or Name Description 22363.1 Fiberglass Side-Hinged Door Unit 6'-8"Opaque I/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.17-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +60/-65 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0187.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 3'-0"x 6'-8" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ, but not in the Wind Borne Debris FL22363 R5 AE 514010A.pdf Region. See DWG-MA-WL0187 for details. FL22363 R5 AE 514014A.pdf Created by Independent Third Party: Yes 22363.2 Fiberglass Side-Hinged Door Unit 6-8"Opaque O/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.17-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +60/-60 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0187.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation &Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 3'-0"x 6'-8" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ, but not in the Wind Borne Debris FL22363 R5 AE 514010A.pdf Region. See DWG-MA-WL0187 for details. FL22363 R5 AE 514014A.pdf Created by Independent Third Party:Yes 22363.3 Fiberglass Side-Hinged Door Unit 6'-8"Opaque I/S or O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.17-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0187.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation &Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 6'-8" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ, but not in the Wind Borne Debris FL22363 R5 AE 514008A.pdf Region. See DWG-MA-WL0187 for details. FL22363 R5 AE 514012A.pdf Created by Independent Third Party: Yes 22363.4 Fiberglass Side-Hinged Door Unit 6'-8"Glazed I/S or O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.03-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +40/-40 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0189.pdf Building Code,including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 6'-8" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ and the Wind Borne Debris Region. FL22363 R5 AE 514008A.pdf See DWG-MA-WL0189 for details. FL22363 R5 AE 514012A.pdf Created by Independent Third Party: Yes 22363.5 Fiberglass Side-Hinged Door Unit 6'-8"3/4-Lite Glazed I/S or O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 RS C CAC NI013717.04-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II F1_0193.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 6'-8" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ and the Wind Borne Debris Region. FL22363 R5 AE 514008A.pdf See DWG-MA-WL0193 for details. FL22363 R5 AE 514012A.pdf Created by Independent Third Party: Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7Ro8yOHRga2pQyiOfQKBIkVjnFjOV8Q%3d°/a3d 2/4 9/24/2020 Florida Building Code Online 22363.6 Fiberglass Side-Hinged Door Unit 6'-8"Impact Glazed I/S or O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL22363 R5 C CAC NI013717.05-R3.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL 0195.pdf Building Code,excluding the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 6'-8" max nominal size. Hurricane protective Evaluation Reports system not required in the Wind Borne Debris Region. See FL22363 R5 AE 514008A.pdf DWG-MA-WL0195 for details. FL22363 R5 AE 514012A.pdf Created by Independent Third Party:Yes 22363.7 Fiberglass Side-Hinged Door Unit 8'-0"Opaque I/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.18-R1.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +60/-65 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0188.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 3'-0"x 8'-0" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ, but not in the Wind Borne Debris FL22363 R5 AE 514009A.pdf Region. See DWG-MA-WL0188 for details. FL22363 R5 AE 514013A.pdf Created by Independent Third Party: Yes 22363.8 Fiberglass Side-Hinged Door Unit 8'-0"Opaque O/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.18-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +60/-60 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0188.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 3'-0"x 8'-0" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ, but not in the Wind Borne Debris FL22363 R5 AE 514009A.pdf Region. See DWG-MA-WL0188 for details. FL22363 R5 AE 514013A.pdf Created by Independent Third Party: Yes 22363.9 Fiberglass Side-Hinged Door Unit 8'-0"Opaque I/S or O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.18-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0188.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 8'-0" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ, but not in the Wind Borne Debris FL22363 R5 AE 514007A.pdf Region. See DWG-MA-WL0188 for details. FL22363 R5 AE 514011A.pdf Created by Independent Third Party: Yes 22363.10 Fiberglass Side-Hinged Door Unit 8'-0"Glazed I/S or O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.08-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +40/-40 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0190.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation &Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 8'-0" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ and the Wind Borne Debris Region. FL22363 R5 AE 514007A.pdf See DWG-MA-WL0190 for details. FL22363 R5 AE 514011A.pdf Created by Independent Third Party: Yes 22363.11 Fiberglass Side-Hinged Door Unit 8'-0"Impact Glazed I/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL22363 R5 C CAC NI013717.09-112.pdf https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7Ro8yOHRga2pQyiOfQKBIkVinFjOV8Q%3d%3d 3/4 9/24/2020 Florida Building Code Online Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +40/-45 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL 0196.pdf Building Code, excluding the High Velocity Hurricane Zone, and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 8'-0" max nominal size. Hurricane protective Evaluation Reports system not required in the Wind Borne Debris Region. See FL22363 R5 AE 514007A.pdf DWG-MA-WL0196 for details. FL22363 R5 AE 514011A.pdf Created by Independent Third Party: Yes 22363.12 Fiberglass Side-Hinged Door Unit 8'-0"Impact Glazed C/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL22363 R5 C CAC NI013717.09-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +45/-40 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL 0196.pdf Building Code,excluding the High Velocity Hurricane Zone, and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 8'-0" max nominal size. Hurricane protective Evaluation Reports system not required in the Wind Borne Debris Region.See FL22363 R5 AE 514007A.pdf DWG-MA-WL0196 for details. FL22363 R5 AE 514011A.pdf Created by Independent Third Party: Yes 22363.13 HPC Fiberglass Side-Hinged Door 8'-0"Glazed I/S or C/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.07-R1.01f Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +47/-47 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0192.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 8'-0" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ and in the Wind Borne Debris Region. FL22363 R5 AE 514007A.pdf Door top rails stamped "HPC". See DWG-MA-WL0192 for FL22363 R5 AE 514011A.pdf details. Created by Independent Third Party: Yes 22363.14 HPC Fiberglass Side-Hinged Door 6'-8"Glazed I/S or C/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.02-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II F1_0191.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do exceed the design pressures Created by Independent Third Party: listed. 12'-0"x 6'-8" max nominal size. Hurricane protective Evaluation Reports system required in HVHZ and the Wind Borne Debris Region. FL22363 R5 AE 514008A.pdf Door top rails stamped "HPC". See DWG-MA-WL0191 for FL22363 R5 AE 514012A.pdf details. Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® _eCheik M Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7Ro8yOHRga2pQyiOfQKBIkVjnFjOV8Q%3d%3d 4/4 Design Pressure: +40/-45 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22363 R5 II FL 0196.1)df Building Code,excluding the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size. Hurricane Evaluation Reports protective system not required in the Wind Borne Debris FL22363 R5 AE 514007A.Ddf Region.See DWG-MA-WL0196 for details. FL22363 R5 AE 514011A.Ddf Created by Independent Third Party:Yes 22363.12 Fiberglass Side-Hinged Door Unit 8'-0"Impact Glazed O/S Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL22363 R5 C CAC NI013717.09-R2.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure: +45/-40 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL 0196.0df Building Code,excluding the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do exceed the design Created by Independent Third Party: ressures listed. 12'-0"x 8'-0"max nominal size. Hurricane Evaluation Reports pr ective system not required in the Wind Borne Debris FL22363 R5 AE 514007A.Ddf Reg, n.See DWG-MA-WL0196 for details. FL22363 R5 AE 514011A.Ddf Created by Independent Third Party:Yes . 2236 .13 HPC Fiberglass Side-Hinged Door 8'-0"Glazed I/S or O/S Single or Double Door w/or w/o Unit Sidelites imits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC NI013717.07-R1.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 05/31/2021 Design Pressure: +47/-47 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0192.Ddf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size. Hurricane Evaluation Reports protective system required in HVHZ and in the Wind Borne FL22363 R5 AE 514007A.Ddf Debris Region. Door top rails stamped"HPC".See DWG-MA- FL22363 R5 AE 514011A.pdf WL0192 for details. Created by Independent Third Party:Yes 22363.14 HPC Fiberglass Side-Hinged Door 6'-8"Glazed I/S or O/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22363 R5 C CAC N1013717.02-R2.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22363 R5 II FL0191.odf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size. Hurricane Evaluation Reports protective system required in HVHZ and the Wind Borne FL22363 R5 AE 514008A.13df Debris Region. Door top rails stamped"HPC".See DWG-MA- FL22363 R5 AE 514012A.Ddf WL0191 for details. Created by Independent Third Party:Yes 0 0 I Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a I personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. , Product Approval Accepts: tr4• ® eC hec emlm Credit Card Safe i Ln 1111 MASONITC. 0 HPC FIBERGLASS DOOR UNIT 149•MAX. Eluu FRAME vnDTH ov J O 8'-0"DOUBLE DOOR WITH/WITHOUT SIDELITES Z 21" MAX 36.375' MAX. � MAX. _O GENERAL NOTES -D.L.O. PANEL WIDTH FRAME WIDTH ~ �O W/ASTRAGAL 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO R 0 THE FLORIDA BREQUIREMENTS CILDING ODE DETERMINED BY ASCEE ESSURE 7,RMINIMUM Lu Q.U DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, -_ DOES-NOT EXCEED THE DESIGN PRESSURES LISTED. L`�1L0U 2. WHEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ), ` Ln HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. 0 0 ^(/) 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, o h HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. a 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. _ 5. PLASTICS TESTING: TEST DESCRIPTION DESIGNATION FACING LITE FRAME cd SELF IGNITION TEMP ASTM D1929 752 'F > S 50 'F 42 'F >8.28RATE BURNING ASTM 63 0.56 IN MIN IN/MIN T28MOKE D3 65 0 'F 3 n a fzn 53.4% 70.27 $J TENSILE STRENGTH- ASTM D638 3.2% DIFF 1.8% DIFF 6. PLASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED): TEST LT SELF IGNITION DESCRIPTION EMP ASTM D1929 779U F > 650 'F RATE OF BURNING ASTM D635 0.0 IN MIN o SMOKE DENSITY ASTM 02843 39.0% p TENSILE STRENGTH- ASTM D638 3.6% DIFFLL a a • COMPARATIVE TENSILE STRENGTH AFTER WEATHERING 4500 HOURS XENON ARC METHOD 1 3>- 7. DOOR SLABS MUST BE STAMPED "HPC' ON TOP RAIL, pOUBLE DOOR UNIT W/SIDELIES V m (N 0 z n �w SINGLE DOOR UNIT DOUBLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT W/SIDELITES DOUBLE DOOR UNIT W/SIDELITES a o WITH SIDELIE WITH SIDELITE WHERE WATER INFILTRATION PERFORMANCE IS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE CONFIG MAX WIDTH INSWING OUTSWING INSWING BUMPER 0 S Z-SERIES 0 S .4 0 .. HIGH DAM 0 S X 37.5 +47.0 -47.0 +47.0 NA +25.0 T S -4 . . 0 -47.0 -47.0 +47.0 - 70 +25.0 -25.0 -47.0XX 74 N . +47.0 -470 40 7.0 -47.0OX or XO 75 A ¢ z 4126117 OXO 112.5 +47.0 -47.0 +47.0 -47.0 N A +25.0 -25.0 +40.0 -40.0 +47.0 -47.0 +47.0 1 -47.0 4r je 09 scALE: N.T.S. TABLE OF CONTENTS OXXO 149 +47.0 -47.0 +47.0 -47.0 N A +2 .0 -2 .0 +40.0 -40.0 +47.0 -47.0 +47.0 -47.0 DWG.aY: - __ SHEET DESCRIPTION AGdenBn bNNA CHN.B1: 1 TYPICAL ELEVATIONS & GENERAL NOTES KURT BALTHAZOR 2 ANCHORING LOCATIONS & DETAILS FLORIDA P.E. OH�wwc uo.: 3 ANCHORING LOCATIONS & DETAILS " � J56533 DWG-MA-FL0192-17 -- - -- --_ -- 4 - ANCHORING LOCATIONS & DETAILS - ------- -- --- ----------- -------- - -- - - - - - - -�-- ---- I SHEET 1 OF 3 u. y 6- SEE DETAIL 6• —{ 3• E. �3- Do D —1 3• 1 3" 3• 3" r 3" 1— T- — 6• 6" r W QQ N — rN Q I 07 a - - -,--- > SEE DETAIL _ LT)U •D• Z L S — w N K w _ N 0 O _ I B g g IY SEE DETAIL io SEE NO-- •c. o A N "C• — A H m �a S. 3• Oc c c Il , r •1 •� , I � o� 0 I- o 3- 3- 3- 3• 3 3. f 3. T� •{ 6• 6" �a a to !/ SEE DETAIL 6• #8 x 2" 3 m -F• ASTRAGAL RETAINER BOLT HOLE V) ® MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE #8 x 2 #10 x 5/8" STRUCTURE DEEP ENOUGH a FOR A 1.375" THROW a #10 x 5/8" DETAIL "E" ASTRAGAL DETAIL "F" ASTRAGAL Z #8 x 2" #10 x 1" ATTACH ASTRAGAL RETAINER BOLT '` g #10 x 2-1 12 STRIKE PLATE TO FRAME. o V) 0 #10 x 1" AS SHOWN. � #7 0 x 518" DETAIL "C" DETAIL "D" 'wammimmmm r ar r/r urza GAO r ae rrr oauAlcn ails w (QI WA)Nm17 MC ACNE SOW N O 4 0.962 1 flv r - ELORM4R"', �—ma.iom. UAm-, f .ma.•ma. 1�Q,�, fe x 1-1/a•ne 1.376• '��`� DebRe+EAe is■r ns ann,roar,a uew sPAaa aims row a�A<sAitm TT Wr M&T ,1r an HOr kur = am ¢Z INSWING THRESHOLD BUMPER O S THRESHOLD n"S"UM °AS01Q" K mrnem immm ummra promos 4 26 17 1 TYPIC4L zLAZING OETAfL ALTERNATE GL4ZING DETAIL Scut: N.T.S. --_ 1.482• 1.75•ajll.047" NON-1MPAGT GLecS NON-IMPACT GLASS 9�5) ri catu.sr: T T 1.437• T MWMC NO.: DWG-MA-FLO192-17 Z—SERIES 0/S THRESHOLD HIGH DAM DAM OAS THRESHOLDTHRESHOLDT4 OAS THRESHOLDTHRESHOLD_- _ -- --- - � -- ----------- -— - - --- — SHM 2 OF 4 I I a i 26' 26" — 26' — 7.375" n to 'm =o NP I W a W I to N m rn m 'm Ul mpm -=iy W rn C w �y N r ` N I 1 I i I I W O� Of W I � W � i I 6' MORE EQUALLY SPACED —6Li4f CL 37.125" om 'm N O W =m W N� 1 I � — w I I —T W T� m n w 1 R C% w is wI 011 I m T I W 4 MORE EQUALLY SPACED 6" m 6• i x PRODUCT: f ,W Ie'on a cn MASONITE INTERNATIONAL CORP. amuIXE DOOR W" 1955 POWIS RD. PART OR ASSEMBLY: A 11 27 17 PDATED DA A S S ANCHORING LOCATIONS WEST CHICAGO, IL. 60185 N0. DATE 9Y �DETAILS t REVISIONS U O z o� o �— co I 1.25" MIN ° f. ° x ¢ Q MAX1.50" MIN I " .' f... 0.25" MIN 0.25" c U MAX MpX SHIM `SHIM SHIM W L U CL I I— ,., CL_I I— -.w CL_I I— OLo F— H' :.In a •' ca - TYPICAL MASONRY 1X BUCK MASONRY TYPICAL WOOD BUCK ANCHOR INSTALLATION ANCHOR INSTALLATION ANCHOR INSTALLATION kit z IE �nbmmt77Ji � w z m o Ad 0 0 a a 3} ATTACHMENT DETAIL I I N m 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, HARDWARE SCHEDULE SIGNED AND SEALED BY ROBERTO LOMAS, PE — (FLORIDA #62514) WITH THE LOWEST (LEAST) 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND FASTENER RATING FROM THE DIFFERENT FASTENERS SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED o BEING CONSIDERED FOR USE. JAMB, HEAD, AND AT 10-1/2" CENTERLINE. (A THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE o g #10 WOOD SCREWS, 1/4" TAPCONS, AND #10 TEK SCREWS. 2. 4" X 4" FULL MORTISE BUTT HINGES. o 0 A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3/4". TEK SCREW EDGE DISTANCE MIN 1/2". No 2. ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO ACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE. 1'X1�2" CORRUGATED #1oX2" WOOD SCREW 3" ROM EACH END 6" FROM EACH END (3) �10X2—g2" (4) N10X2-1 2" 3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM AND 7" OC AND 12" oC Wo D SCR E4YS O D SCR ¢z ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT ACRYLIC EACH END EACH END OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE CAULK ® ® w� 4126117 MINIMUM EMBEDMENT OF 1-1/4". ACRYLIC ® Sc F• N.T.S. LATEX 4.-- WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO CAULK -CL ® a ®® --- DWG•BY, SWS — TRANSFER LOADS TO STRUCTURE. f cma ar: COMBINATION WOOD COMBINATION WOOD INTEGRAL WOOD INTEGRAL WW DRAWING NO.: 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. MULLION _(BOXED) _MULLION_(BOXED)--- MULLION-(CHS) -MULLION-(GHS)-- DWG_iu=FLo7s2-n -- - sHm 4 OF 4