RESiDENTIAL. ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the
residential Simulated Performance !Method shall include:
Q,> This checklist
A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a -ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report (one page) and an input summary checklist that can
be used for field verification (usually four pages/may be greater).
Energy Performance Level (EPL) Display Card (one page)
.D HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
F1 Mandatory Requirements (five pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and insulation Inspection Component Criteria checklist (Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report (usually one page)
0 If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report (usually one page)
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
FILE C&Y
1/2/2020 8:09:35 AM EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
y FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: OUTDOOR INVESTMENT
Builder Name:
Street:
Permit Office: FT PIERCE
City, State, Zip: FT PIERCE, FL,
Permit Number;
Owner.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 }
1. New construction or existing • New (From Plans)
9_ Wall Types (1700.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1450.00 ftz
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 250.00 ftz
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftZ
5. Is this a worst case? Yes
10. Ceiling Types (1573.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1573.00 ftZ
6. Conditioned floor area above grade (ftZ) 1573
b. N/A
R= ftz
Conditioned floor area below grade (ftZ) 0
R z
7. Windows(144.0 sgft.) Description Area
11 Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ftz
6 141
a. U-Factor. Dbl, U=0.96 144.00 ftz
SHGC: SHGC=0.42
b. U-Factor: N/A ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
33.6 SEER:15.00
c. U-Factor: N/A ftZ
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. NIA ftZ
a. Electric Heat Pump
32.4 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.667 ft.
Area Weighted Average SHGC: 0.420
14. Hot water systems
8. Floor Types (1573.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1573.00 ftz
b. Conservation features
EF: 0.920
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.092 Total Proposed Modified Loads: 52.89
PASS
Total Baseline
Loads: 56.10
I hereby certify that the plans and specifications covered by
Review of the plans and
S74A�"
this calculation are in compliance with the Florida Energy
specifications covered by this
O111iE
0'
Code. r
15
calculation indicates compliance
with the Florida Energy Code.
::m:, ,z , `- ', ,,.�`�-. 0
PREPARED BY: t
Before construction is completed
_ -•.. ,.c
s building�.
this will be inspected for
compliance with Section 553.908
• .
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
,�
with the Florida Energy Code.
G
OWNER/AGENT:_WE
6/: �/i�lAPdA
BUILDING OFFICIAL:
DATE: :NJ 120? 2a
DATE:
_
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R4 22..4 _aqd t c ct requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4 G �hU r 1'�
CODE COMPLIANCE
ST. LUCIE COUNTY
112/2020 8:09 AM EnergyGauge®R USA 6.0.02 (Rev. 1) - F Res 1LFB EdiCificEi-plianisoftware
Page 1 of 4
FORM R405-2017 IFi PHT R lMMARY r.HFr-K1 IRT RFPnPT
-�
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
OUTDOOR INVESTMENT Bedrooms: 3
User Conditioned Area: 1573
Total Stories: 1
1 Worst Case: Yes
Rotate Angle: 270
FT PIERCE Cross Ventilation:
Whole House Fan:
Single-family
New (From Plans)
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street:
County: St. Lucie
City, State, Zip: FT PIERCE,
FL.
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH MUNI 39 90
70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1573 15730
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1673 15730 Yes 8
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 178 ft 0
1573 ft2 _—_ 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emift Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Hip Composition shingles 1704 ft2 0 ft2 Medium
N 0.96 No 0.9 No 0 22.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 1573 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
i
Under Attic (Vented)
Main 30 Blown
1573 ft2 0.11 Wood
1/2/2020 8:09 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
SpaceFoactsonArpqRAIRlium
Ah�nrrrpirlpin
1 N=>W Exterior Concrete Block - Int Insul Main
4.0999 32 10
320.0 ft2
0 0.15
0
2 E=>N Exterior Concrete Block - Int Insul Main
4.0999 42 10
420.0 ft2
0 0.15
0
-3 S=>E Exterior Concrete Block - Int Insul Main
4.0999 18 10
180.0 ft2
0 0.15
0
4 W=>S Exterior Concrete Block - Int Insul Main
4.0999 53 10
530.0 ft2
0 0.15
0
5 S=>E Garage Frame - Wood Main
11 13 10
130.0 ft2
0.11 0.15
0
6 W=>S Garage Frame - Wood Main
11 12 10
120.0 ft2
0.11 0.15
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 S=>E Insulated Main
None
.46 3
8
24 ft2
2 S=>E Wood Main
None
.46 2
8
6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation (_>) changed to Worst Case.
Wall
Overhang
# Omt 1D Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1 N=>W 1 Metal Double (Tinted) Yes
0.96 0.42 N
15.0 ft2 2 ft 0 in
1 ft 0 in
None
None
2 N=>W 1 Metal Double Mnted) Yes
0.96 0.42 N
24.0 ft2 12 ft 0 in
0 ft 6 in
None
None
3 E=>N 2 Metal Double (Tinted) Yes
0.96 0.42 N
15.0 ft2 2 ft 0 in
1 ft 0 in
None
None
4 S=>E 3 Metal Double (Tinted) Yes
0.96 0.42 N
22.5 ft2 2 ft 0 in
1 ft 0 in
None
None
5 S=>E 3 Metal Double (Tinted) Yes
0.96 0.42 N
15.0 ft2 2 ft 0 in
1 ft 0 in
None
None
6 W=>S 4 Metal Double (Tinted) Yes
0.96 0.42 N
30.0 ft2 2 ft 0 in
1 ft 0 in
None
None
7 W=>S 4 Metal Double (Tinted) Yes
0.96 0.42 N
22.5 ft2 2 ft 0 in
1 ft 0 in
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 234 ft2 234 ft2
64 ft
8 ft
1
INFILTRATION!
# Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000445
1835.2 100.75 189.47 .1685
7
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts-
1 Electric Heat Pump/ None
Sing) HSPF:8.5
32.4 kBtu/hr
1
sys#1
1/2/2020 8:09 AM EnergyGauae® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
None
Singl SEER: 15 33.6 kBtu/hr 1008 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.92 40 gal 60 gal
120 deg
None
j
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
— Supply --
V # Location R-Value Area
- — Return — Air
Location Area Leakage Type Handler
CFM 25 CFM25
TOT OUT QN
RLF
HVAC #
Heat Cool
1 Attic 6 141 ftz
Attic
40.25 ft Default Leakage Garage
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb Mar
Mar
He f X� Jan Feb ki
Ventin [ Jan Feb Mar
f
[X
Ceiling Fans:
A r may Jun nJul Auge
APr May Jun Jul AuSep
Apr May Jun Jul Aug
Se [X
Oct
Oct
Oct
j Nov
X] Nov
[X] Nov
[ ] Dec
[X] Dec
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2
3
Hours
4 5 6 7
8 9
10
11
12
Cooling (WD) AM 78
PM 80
Cooling (WEH) AM 78
PM 78
Heating (WD) AM 65
PM 68
Heating (WEH) AM 66
PM 68
78
80
78
78
66
68
66
68
78
78
78
78
66
68
66
68
78 78 78 78
78 78 78 78
78 78 78 78
78 78 78 78
66 66 68 68
68 68 68 68
66 66 68 68
68 68 68 68
78 80
78 78
78 78
78 78
68 68
68 68
68 68
68 68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MECHANICAL VENTILATION
Type Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time Cooling System
None 0
0
0 1 - Electric Heat Pum
0%
1 - Central Unit
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ftz
0 ft 0.3
Main
1/2/2020 8:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) D9SPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX' = 94
The louver the Energy
Performance Index,
the more efficient the horse.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Garage
3. No_ of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
33.6
a) Split system SEER
5_ Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6_ Conditioned floor area (sq. ft.)
6.
1573
d) Room unit/PTAC EER
e) Other
15.0
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.960
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.420
14. Heating system: Capacity
32.4
c) Area
7c.
144.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
fl Other
8.50
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.92
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature_ -1 Date: 2Z/zzZePZ(o,
Address of New Home: )6( )( C?liyPA City/FL Zip: FT PIERCE, FL
1/2/2020 8:09:38 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
Permit Number.
FT PIERCE, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
IN
SECTION R401 GENERAL
EJ R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal enveloT)be building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation -The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be tumed off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air leakage Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2,6 Lts/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
1/2/2020 8:09 AM EnergyGauge® USA 5.0.02 (Rev. 1) - FlaRes2017 FSC 6th Edition (2017) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
DR402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
F] R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1 Controls. SECTION R403 SYSTEMS
R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating toad.
R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/iCC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(% (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1 _ Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C)
or below 55°F (13°C) shall be insulated to a minimum of R-3.
El R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
EJ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
❑ R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
1/2/2020 8:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
OR403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 % inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38°C to 60°C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
❑ R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
EJ ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
Fi R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403,6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For $I: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916
1/2/2020 8:09 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
MANDATORY REWRE ENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
2. calculated total sensible load but not less than 80 percent of that load.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options.
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
❑
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or extemal to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation_
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
® R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
1/2/2020 8:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (MandatorAhe energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404 ,
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
0 1/2/2020 5:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: OUTDOOR INVESTMENT Builder Name:
Street: Permit Office: FT PIERCE
City, State, Zip: FT PIERCE, FL, Permit Number.
Y
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealingmaterial.
Breaks orjoints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped Ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
floors)
shall be permitted to be in contact with the top side
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
on exterior wall
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
tubs shall separate them from the showers and tubs_
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In additinna - insnctinn
inki
nP Inn u A HK tie �., ,...a...........:.� ,
- - - -.'-.. _.._, ,,, o....v,uc, WAL11 uic Niwiswns of [U%u 4Uu.
1/2/2020 8:09 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction:
Permit #:
,...:,..:... t,.t,.,l
,.a,. .,,.nvn .r,Y.-n.,-tlr,. �: r, .,,.: •::, .:.'<.: ,1.:: n.}_::,. ,,•:
g� o anon
.r
Builder. Community: Lot: NA
Address:
City: FT PIERCE State: FL Zip:
L r
"e=Til?Sts . e ...:.:....:.Passrn . ccesutts, must meet:eitliertlie:Relfor�a%zce` Prescri � t�:ve �.o 'ER ' .e
.. _. . f,1 n >z..e... r-r .,..:. z.�ut... -.r. :.:.... ... .... .: .....:.. .. ..._....... .r ... _ .. _ .... ..-. _.... _....,. ......,:.�: -: �.ti'i,..
,��Pt�ESC,R1RTl)7£tlAE7tiODr't3ie.buildmg�-or'clwelllrigsun�.�stialtbetesteda[;d::verrfied:as:y,av�ng>ati.`.air>leaka e:;rateofnotrexceedin 7air:.
r
u / .:r
..._ .:,.u:::::n•.,.;.; .:{;�..,,::.tia,:�::: ::i:t.:..'.:?';::Sir:;:::=jV, '
au't'".,::•p::^.:i•.: ,:'.�Y:r':h'::.a `:',.:.:.s:.::'V.:':.�:•r",:,1'�.::r.;._.r:.._...:,: .., r_..:.....• -
._ , t i,� 1 . .... ... ,(: 'r .,?: r . _.,. ,. ., > . , r { .. .. _).. - ti+}9::::Nr: .:1:,: •::. ,;-fir..
PERFQF�M�WCE?orER111AETNOD-i e;bi]ildi' :�. ::dwetfi' rreshal}rEie'testecf'a V ' d.,, eifie" ias.havn aparrreaka'erate�,of;naf exceedin"'
g•
,,�„(:M,A.i'f5,,.y,xy.k.:e,,. .,r,' >��,•: �rt� a4�;:. �,,,; ;1�,.�!,.,,Qu,�,,_.,f ���k£c..:`i.9ii"�`t+;c(::, ni,:e!�, „�d,�
..�..1..:,,.,9.. ,,,,' .,,J,•, Y t 7 -ice 1. , �a„e•tr_'nN• .AJ' � ar.^
K,th iself:cfed'AEH�5t))uvalue as-s ow ton Forro`)R405- 0 7� Pe ' a ?11n Itra "'° `� it ii'`'AGkI'505
i�� .fr ,,4 � /r L+f� UJ rttb! S _ ln�`�& %1 F r„AP, 1 � 1, 5 . -
{ r tl r�lijtr}r r• �rrx�li 11 r J'' i � ro , a,x'lt
i,fL,,t ,it�y t fH{50);spPcriled oSFttprrrrRag05�2)?j. EF►etcCalG>(Pecf�rman�eJ,ol d(Jt r�201r7, fE 7.000
flsa `.c.., I ..Uti� r.lf,l,•"r•,fi a;r'i i.i,'. tJ C •9 r, M >fr,,4 _. ,,..: ... ,..,.. %. :.=�aiG}:;t.�!4..�.�:f.:a<. .t+:: r. A h , .
x 60 15730 = Method for calculatinq building volume:
CFM(50) Building Volume ACH(50)
O Retrieved from architectural plans
F� PASS Code
@ software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation Q Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489,105(3)(f) (g), or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
1
ar >, , ,�,J.. .;r c' ,>i'. 5 �t . f!ti �.'n:. 7 j.73 esi '`.n,.a, � ,j•. � i o . i '. {h. i, ,r :r,-+i yam' r„ f
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester-
License/Certification #: Issuing Authority:
1/2/2020 8:09:40 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Residential System SlizingCalculation
Summary
Project Title:
OUTDOOR INVESTMENT
FT PIERCE, FL
1 /1 /2020
Location for weather data: Fort Pierce, FL - Defaults: Latitude(27.48) Altitude(25 ft.) Temp Range(L)
Humidi data: Interior RH 50%
Outdoor
wet bulb 78F
Humidity difference 62 r.
Winter design temper6ture(TMY3
99%) 40
F
Summer design temperature(TMY3 99%) 91
F
Winter setpoint
70
F
Summer setpoint
75
F
Winter temperature difference
30
F
Summer tem erature difference
16
F
Total heating load calculation
25706
Btuh
Total cooling load calculation
30659
Btuh
Submitted heating capacity
% of calc
Btuh
Submitted cooling capacity
% of calc
Btuh
Total (Electric Heat Pump)
126.0
32400
Sensible (SHR = 0.75)
99.7
25200
Heat Pump + Auxiliary(O.OkW)
126.0
32400
Latent
155.8
8400
Total Electric Heat Pump)
109.6
33600
WINTER CALCULATIONS
Winter Heatinq Load (for 1573 soft
Load component
Load
Window total
144
sqft
4147
Btuh
Wall total
1514
sqft
6400
Btuh
Door total
42
sqft
577
Btuh
Ceiling total
1573
sqft
1503
Btuh
Floor total
1573
sqft
6301
Btuh
Infiltration
71
cfm
2331
Btuh
Duct loss
4446
Btuh
Subtotal
25706
Btuh
Ventilation
0
cfm
0
Btuh
TOTAL HEAT LOSS
1
25706
Btuh
573
';:'alls(7l CXI s
1 Ftoors NZW
SUMMER CALCULATIONS noorst�z=s, Infil.{s.i?,,
Ceilinos;b,6;Sl
Window total
144 sqft
Wall total
1514 sqft
Door total
42 sqft
Ceiling total
1573 sqft
Floor total
Infiltration
53 cfm
Internal gain
Duct gain
Sens. Ventilation
0 cfm
Blower Load
Total sensible gain
Latent gain(ducts)
Latent gain(infiltration)
Latent gain (ventilation)
Latent gain(internal/occupants/other)
Total latent gain
TOTAL HEAT GAIN
6451
3414
596
2254
0
932
6240
5382
0
0
25269
1557
2233
0
1600
5390
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
s Doers.1
Infil,i 13.3'Sl
l--
Du-as;22. F,%, i
Dluctsl,1 i.3
r
;eilin
_ r— a; .
likkk 11 ',Ain dovis (21
Latentintf.-.2%j I
6 , r .o-
IntG-ainf_0,ioi 1
roa.7 stun I t.
EnergyGauge® S.ysfe Si ing,,..
PREPARED BY:
DATE: • ='
EnergyGauge® / USRCZB v6.1.04
a % i I � ' u L1 P: do U <4f n s k e n mT'.^.+ ri+:,.
R side fiaa Load - Room by Room !Compornenk D taic-s
Project Title:
OUTDOOR INVESTMENT
FT PIERCE, FL
1 /1 /2020
Reference City: Fort Pierce, FL Temperature Difference: 16.OF(TMY3 99%) Humidity difference: 62gr.
This calculation is for Worst Case. The house has been rotated 45 degrees.
Type"
Overhang
Window Area(sqft)
HTM
Load
i
Window
Panes SHGC U InSh
IS Omt
Len Hgt
Gross
Shaded Unshadec
Shaded Unshaded
1
2 NFRC 0.42, 0.96 No
No NE
2.Oft 1.0ft
15.0
0.0 i5.0
24
44
660
Btuh
2
2 NFRC 0.42, 0.96 No
No NE
12.Of 0.5ft
24.0
0.0 24.0
s 24
44
1057
Btuh
3
2 NFRC 0.42, 0.96 No
No SE
2.Oft 1.0ft
15.0
7.6 7.4
24
45
518
Btuh
4
2 NFRC 0.42, 0.96 No
No SW
2.Oft 1.0ft
22.5
11.3 11.2
24
45
777
Btuh
5
2 NFRC 0.42, 0.96 No
No SW
2.Oft 1.0ft
15.0
7.6 7.4
24
45
518
Btuh
6
2 NFRC 0.42, 0.96 No
No NW
2.Oft 1.0ft
30.0
0.0 30.0
24
44
1321
Btuh
7
2 NFRC 0.42, 0.96 No
No NW
2.Oft 1.0ft
22.5
0.0 22.5
24
44
991
Btuh
Window Total
1
1
144
(sqft)
5842
Btuh
WallsType
U-Value R-Value
Area(sqft)
HTM
, Load
Cav/Sheath
'
1
Concrete B1k,Hollow - Ext
0.16 4.110.0
281.0
2.4
671
Btuh
2
Concrete Blk, Hollow - Ext
0.15 4.1/0.0
405.0
2.4
967
Btuh
3
Concrete Blk,Hollow - Ext
0.15 4.110.0
118.5
2.4
283
Stuh
4
Concrete Blk,Hollow- Ext
0.15 4.1/0.0
477.5
2.4
1140
Btuh
5
Frame - Wood - Adj
0.09 11.0/0.0
112.2
1.5
170
Btuh '
6
Frame - Wood -Adj
0.09 11.0/0.0
120.0
1.5
182
Btuh
Wall Total
1514 (sqft)
3414
Btuh
Doors
Type
Area (sqft)
HTM
Load
1
Insulated - Exterior
24.0
14.3
342
Btuh r
2
Wood - Garage
17.8
14.3
254
Btuh
Door Total
42 (sqft)
596
Btuh
Ceilings
Type/Color/Surface
U-Value R-Value Area(sqft)
HTM
Load
1
Vented Attic/Light/Shingle
0.032 30.010.0
1573.0
1.43
2254
Btuh
Ceiling Total
1573 (sgft)
2254
Btuh
Floors
. Type
R-Value
Size
HTM
Load
1
Slab On Grade
0.0
1573 (ft-perimeter)
0.0
0
Btuh
Floor Total
1573.0 (sqft)
0
Btuh
Zone Envelope Subtotal:
12106
Btuh
Infiltration
Type
Wholehouse ACH Volume(cuft) Wall Ratio
CFM=
Load
Natural
0.20 15730 1.00
53.0
932
Btuh
Internal
Occupants
Btuh/occupant
Appliance
Load
r_qain
8
X 230 +
4400
6240
Btuh
Sensible Envelope Load:
19278 Btuh
Duct load
Average sealed, Supply(R6.0-Attic), Return (R6.0-Attic)
MGM of 0.271)
5217
Btuh
--
Sensible Zone Load
24495 Btuh
EnergyGauge©/ USRCZB v6.1.04 Paoe 1
FT PIERCE, FL
Residential Load - Component Details (continued)
Project Title: Climate: FL_VERO_BEACH_MUNICI PAL_A
OUTDOOR INVESTMENT
1 /1 /2020
Windows
July excursion for System 1
609 Btuh
Excursion Subtotal:
609 Btuh
Duct load
165 Btuh
Sensible Excursion Load
I
1 774 Btuh 1
EnergyGauge®/ USRCZB v6.1.04 Page 2
FT PIERCE, FL
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL VERO_BEACH_MUNICIPAL_A
OUTDOOR INVESTMENT
1 /1 /2020
Sensible Envelope Load All Zones
19887 Btuh
Sensible Duct Load
5382 Btuh
Total Sensible Zone Loads
25269 Btuh
Sensible ventilation
0 Btuh
Blower
0 Btuh
Whole House
Total sensible gain
25269 Btuh
Totals for Cooling
Latent infiltration gain (for 62 gr. humidity difference)
2233 Btuh
Latent ventilation gain
0 Btuh
Latent duct gain
1557 Btuh
Latent occupant gain (8.0 people @ 200 Btuh per person)
1600 Btuh
Latent other gain
0 Btuh
Latent total gain
5390 Btuh
TOTAL GAIN
30659 Btuh
1. Central Unit # 33600 Btuh
'Key: Window types (Panes - Number and type of panes of glass)
(SHGC - Shading coefficient of glass as SHGC numerical value)
(U - Window U-Factor)
(InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R))
- For Blinds: Assume medium color, half closed
For Draperies: Assume medium weave, half closed
For Roller shades: Assume translucent, half closed
(IS - Insect screen: none(N), Full(F) or Half(%))
(Omt - compass orientation)
Version 8