Loading...
HomeMy WebLinkAboutProduct Approval; Asphalt Shingles Roofingdl��Ilt s (� III II elm t__..�•`�c � � i Viiiiillli9 M1 I m� ��jr1'r4�� � i �1QM Itl � i � � �.�, iq T-r" 'rt'r'Ilk-i'i e y OO 4 [p' r y .j� yp7 r m 0 9 0 4 ��^,^'mom+ Llnks j search .�� lil ugli I ray*r ? stats&Facts Publicatl0ns Contact us 1 BCI$ s to Map BCIs Home Login User Registration 1 Hot Topic, Suboilt Surcharge br � FubhAP Ipler oval -" d p, r Product AjurOVI Men" > Pr°iloc---tor _Ant�llcauo Scarcl > Application List > Application Detail FL10124-R27 i l4 t (i FL # Revision Application Type 2017 Code Version Approved Application Status Comments Archived GAF Product Manufacturer 1 Campus Drive Address/Phone/Email P irisppany, NJ 07054 (801 766-3411 mstieh@gaf.com Authorized Signature Robert NieminenIreith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive D Parsippany, NJ 07054��� (800) 766-3411 �yf� yr IP A C- TechnicalQuestionsGAF@,gaf.com GOMCOU�T� Quality Assurance Representative �� ��C1V Address/Phone/Email o 130 tl Category Roofing �Q 09's Subcategory Asphalt Shingles �1 !d Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Robert Nieminen PE-59166 UL LLC 12/16/2022 John W. Knezevich, PE lam' Validation Checklist - Hardcopy Received FL10124 977 COT 2020 01 M N —M1NEN p.S1f Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 TAS 107 1995 9 Product Approval Method Method 1 Option D. Date Submitted 06/08/2020 Date Validated 06/08/2020 Date Pending FBC Approval 06/12/2020 Date Approved 08/04/2020 Summary of Products FL # Model, Number or Name Description '10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge asphalt shingles Limits of Use Approved for use in HVHZ: No Installation Instructions 1`1_10124 R27 II 2020 06 04 FINAL ER GAF ASPHALT SHINGLES F1_10124-1127.ndf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created -by Independent Third Party: Yes Other: Refer to ER, Section S. Evaluation Reports F1.10124 R77 AE 2020 06 04 FINAL ER GAF ASPHALT SHINGLES FL10124-R27.Ddf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850.487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Safe— NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT p •p• GAF Evaluation Report 01506.01.08-1129 1 Campus Drive Parsippany, NJ 07054 (800)766-3411 FL10124-R27 Date of Issuance: 01/03/2008 Revision 29: 06/04/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be -available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: ..���""'r'��•., " Robert J.M. Nieminen, P.E. ','�^'' F r c ° The facsimile seal appearing was authorized by Robert '.;fiF"•. ��;;s•: ;,,�S�����?�s� �,t Nieminen, P.E. on 06/04/2020. This does not serve as an Florida Registration No. 59166, Florida DC4ANE1983 :�%,,.;.,, « electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOletc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc. is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019, NEMO ETC, LLC OIV EM0 I etc. R©.OFINGSYSTEII%IS�EVAL•UATION ° M 1. SCOPE: Product Category: Rooting Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 6t' Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.1.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entit Examination Reference Date PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI (TST 5878) ASTM D1970 (QuickStart) GAF-340-02-01 03/13/2012 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 PRI (TST 5878) Wind Driven Rain GAF-895-02-01 11/20/2018 PRI (TST 5878) Wind Driven Rain GAF-896-02-01 11/20/2018 PRI (TST 5878) ASTM D3462 GAF-897-02-01 11/08/2018 PRI (TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018 PRI (TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018 UL (TST 1740) ASTM D3462 93NK6295 11/29/1993 UL (TST 1740) ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL (TST 1740) ASTM D3462 01NK06632 02/02/2001 UL (TST 1740) ASTM D3161, TAS 107 01NK9226 05/21/2001 UL (TST 1740) ASTM D3161 01NK37122 12/18/2001 UL (TST 1740) ASTM D3462 01NK37122 12/19/2001 UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002 UL (TST 1740) ASTM D3161 03CA5367 03/11/2003 UL (TST 1740) ASTM D3462 03NK26444 10/17/2003 UL (TST 1740) ASTM D3462 04NK13850 06/07/2004 UL (TST 1740) ASTM D3161 04NK13850 06/23/2004 UL (TST 1740) ASTM D3161 04NK30546 03/10/2005 UL (TST 1740) ASTM D3462 04NK22009 05/06/2005 UL (TST 1740) ASTM D3161 04NK22009 05/09/2005 UL (TST 1740) ASTM D3462 05NK27924 02/10/2006 UL (TST 1740) ASTM D3161 05NK27924 02/11/2006 UL (TST 1740) ASTM D3161, D3462 06CA18077 06/05/2006 UL (TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL (TST 1740) ASTM D3161, D3462 06CA35251 10/19/2006 UL (TST 1740) ASTM D3462 06CA31603 12/01/2006 UL (TST 1740) ASTM D3161, D3462 06CA41095 12/27/2006 UL (TST 1740) ASTM D3161 07NK05228 03/13/2007 MEMO ETC, LLC Evaluation Report 01506.01.08-1129 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R27 GAF Asphalt Roof Shingles Revision 29: 06/04/2020 Page 2 of 7 ONEMO,Jetc. Entity Examination Reference Date UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL (TST 1740) ASTM D3161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007 UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008 UL, LLC. (TST 9628) ASTM D3161 4788698165 03/24/2008 UL (TST 1740) ASTM D3161, D3462 07CA55908 04/01/2008 UL (TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009 UL (TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161, D7158, D3462 10CA35554 03/05/2010 UL (TST 1740) ASTM. D3161, D7158, D3462 10CA13686 05/15/2010 UL (TST 1740) ASTM D3462 10CA07264 05/27/2010 UL (TST 1740) ASTM D3462 10CA11953 10/29/2010 UL (TST 1740) ASTM D3161, D7158, D3462 1ONK11951 10/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 1ONK12070 11/04/2010 UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 01/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 10CA53934 03/31/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011 UL,'LLC. (TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,.LLC. (TST 9628) ASTM D3161, D7158, D3462 12CA58151 02/15/2013 UL, LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013 UL, LLC. (TST 9628) ASTM D3161 13CA32332 06/18/2013 UL, LLC. (TST 9628) ASTM D3161 13CA37934 08/02/2013 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786875675 07/17/2015 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4787434542 05/17/2016 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4788717529 09/09/2016 UL, LLC. (TST 9628) ASTM D3161 4788669132 12/13/2018 UL, LLC. (TST 9628) ASTM D3161 4788891098 02/14/2019 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4788932264 08/16/2019 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4789115488 08/16/2019 UL, LLC. (TST 9628) ASTM D3161 4788959558 10/17/2019 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786508528 11/01/2019 UL, LLC. (TST 9628) ASTM D3161 4789132672 11/27/2019 UL, LLC. (QUA 9625) Quality Control Service Confirmation 10/18/2018 4. , PRODUCT DESCRIPTION: 4.1 ACCESSORY STARTER STRIPS: 4.1.1 Pro -Start® Starter Strip Shingles (tKa, Pro -Start- tave/KaKe -)tarter oLnN annigia�t cli1 vv=p���= �••••� Starter Strip Shingles (fka, WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles) are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 QuickStart® Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-inch or less. Meets ASTM D1970. 4.1.3 StarterMatch® Starter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatch® are installed as the second starter for Grand Canyon® and Grand Sequoia® series, installations. Meets ASTM D3462. NEIVIO ETC, LLC Evaluation Report 01506.01.08-R29 Certificate of Authorization H32455 6- EDITION (2017) FBC NON•FIVHZ EVALUATION FL10124-R27 GAF Asphalt Roof Shingles Revision 29: 06/04/2020 Page 3 of 7 ONEMOletc. 4.2 ASPHALT SHINGLES: 4.2.1 Marquis WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.2.2 Camelot® II, Fortitude'"", Glenwood'"', Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield®, Grand Sequoia® AS, Timberline® American Harvest®, Timberline® AH, Timberline® ArmorShield® II, Timberline® AS II, Timberline® Natural Shadow®, Timberline® NS, Timberline® HD, Timberline® HDZI, Timberline® Cool Series, Timberline® CS, Timberline® Ultra HD, Timberline® UHD and Woodland® are fiberglass reinforced, laminated asphalt roof shingles. 4.2.3 Slateline'm is a fiberglass reinforced 5-tab asphalt roof shingle. 4.3 HIP & RIDGE SHINGLES: 4.3.1 Seal -A -Ridge® Ridge Cap Shingles, Seal -A -Ridge® ArmorShield®, Seal -A -Ridge® AS and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip'and ridge asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEW ETC, LL'C nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 Pro -Start® Starter Strip Shingles (fka, Pro -Start® Eave/Rake Starter Strip Shingles) and WeatherBlockerTI Premium Starter Strip Shingles (fka, WeatherBlocker'"" Premium Eave/Rake Starter Strip Shingles) are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd =150 mph (V„ Ic = 194 mph): 5.4.2 The GAF asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vwd =150 mph (Vutt =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.3 The GAF hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd =150 mph (Vuit =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. NEMO ETC, LLC Evaluation Report 01506.01.08-1129 Certificate of Authorization #32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10124-1127 GAF Asphalt Roof Shingles Revision 29: 06/04/2020 Page 4 of 7 *NEMOletc. 6. - 'INSTALLATION: 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or ,R905.2.5. Staples are not permitted. 6.1.4 GAF asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and GAF published installation instructions. 6.2 STARTER SHINGLES OR STARTER STRIP: 6.2.1 Installation of Pro -Start® Starter Strip Shingles (fka, Pro -Start® Eave/Rake Starter Strip Shingles), WeatherBlocker'"I Premium Starter Strip Shingles (fka, WeatherBlockerlm Premium Eave/Rake Starter Strip Shingles) and QuickStartm Peel & Stick Starter Roll shall comply with the GAF current published instructions. 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published Instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Camelot® 11, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield®, and Woodland® require minimum five (5) nails per shingle. ➢ Slateline'" requires minimum six (6) nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.2.1 Fastening for Fortitude`"", Timberline® AH, Timberline® CS and Timberline® HDZTI; slopes 2:12 up to 21:12 39-3/8" (tin) 4 11-52• • 14.518• (295mm - 372mm) 11.5/8'-14.5/8' (295mm - 372mm) 1l2 •2-12 113rom-64mm) 112 2172 (13mm-64mm) 13-1/4' TARGET NAIL ZONE ZONA OBJETIVO DE GLAVADO 5-13116-- 7-5/8' (148mn1- 194mm) 6 7/8' 117nn7 I STANDARD NAILING PATTERN: Nail shingles approximately 6 7/8' (174 nnn) from bottom of shingle, in nailing area, as shown. Nails must not be exposed. Not for use on Mansard roofs (21:12 slope and above). 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. NEMO ETC, LLC Evaluation Report 01506.01.08-R29 Certificate of Authorization #32455 6Tu EDITION (2017) FBC NON-HVHZ EVALUATION FL10124rR27 GAF Asphalt Roof Shingles Revision 29: 06/04/2020 Page 5 of 7 UN'NEMOjetc. 6.3.3.1 Fastening fnr Fnrtitifriplm TimhcrlinnO A Tiw.h...i:....® r-c .. 6.4 HIP & RIDGE SHINGLES: 6.4:1 Installation of Seal -A -Ridge® Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter .located 6-7/8-inch back from the exposed end and 0.5-inch from the edge. 1 r- \ Claw Clouer .r 6.4.2 Installation of Seal -A -Ridge® ArmorShield® and Seal -A -Ridge® AS shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle located 6 to 6.5-inch back from the exposed end and 1 to 2-inch from the edge, and nominal 0.25-inch diameter beads of Henkel "Loctite PL S30 Roof & Flashing Sealant". 11.5' 1. (292 mm) 1 Sealant (25 mm) (25 mm) 1 1, • • 12' Nail (305 mm) (152 mm—I165 mm) i 12' (305 mm) NEMO ETC, LLC Evaluation Report 01506.01.08-1129 Certificate of Authorization 932455 6-'EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R27 GAF Asphalt Roof Shingles Revision 29: 06/04/2020 Page 6 of 7 6.4.3 Installation of Timbertex® Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn "NP1 Gun Grade Polyurethane Sealant" or Henkel "PL Roofing and Flashing Sealant". NNEMOjetc- 1• 11.5° (292 mm) Sealant 1" Sellanle (25 mm) (25 mm) Ehduit d'dtancheild Is Nail 12° Clavo (305 mm) Clouer 9. (229 mm) U 12' --- 1 (305 mm) 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS:' As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20- 3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT - MEMO ETC, LLC Evaluation Report 01506.01.08-1129 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION, FL10124-R27 GAF Asphalt Roof Shingles Revision 29: 06/04/2020 Page 7 of 7 Royal s'ov rergn®`Shiln:g1 - Think all strip shingles look pretty much alike? Not so! We've gone to great pains to make Royal Sovereign°Shingles the most beautiful strip shingle on the market. Not eligible for the Lifetime Roofing System F;,7ol�z MMMMMMMMM SEE ALL COLORS ) O Showing products available near 32203 CHANGE) Q * * * * * Read Reviews ABOUT (NTFPS://WW W.GAF.COM/EN- US/ROOFING- PRODUCTS/RESIDENTIAL- ROOFING PRODUCTS/SHINGLES/3- SPECS (HTTPS://W W W.GAF.COM/EN- US/ROOFING PRODUCTS/RESIDENTIAL- ROOFING PRODUCTS/SHINGLES/3- DOCS (HTrPS: / / W W W.GAF.COM/EN- US/ROOFING PRODUCTS/RESIDENTIAL- ROOFING PRODUCTS/SHINGLES/3- VIDEOS (HTrPS:/ /W W W.GAF COM/EN- US/ROOFING PRODUCTS/RESIDENTIAL- ROOFING PRODUCTS/SHINGLES/3-