Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 k FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: PEREZ GUEST RESIDENCE Builder Name: Street: ORANGE AVE & BRIDLEWOOD WAY Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, - Permit Number: Owner: PEREZ Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (948.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 948.00 ftz b. N/A R= ftz 3, Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 1 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (689.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=4.0 689.00 ftz 6. Conditioned floor area above grade (ftz) 689 b. N/A R= ftz 1. Conditioned floor area below grade (ft2) 0 c. N/A R= ftz 11. Ducts R ftz 7. Windows(83.5 sqft.) Description Area a. U-Factor: Sgl, default 83.50 ftz SHGC: Tinted, default b. U-Factor: N/A ftz 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Strip Heat 16.4 COPA.00 SHGC: Area Weighted Average Overhang Depth: 5.880 ft. Area Weighted Average SHGC: 0.640 14. Hot water systems a. Propane Tankless Cap: 1 gallons 8. Floor Types (689.0 sgft.) Insulation Area EF: 0.800 a. Slab -On -Grade Ede Insulation R=0.0 689.00 ftz 9 b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15. Credits Pstat Glass/Floor Area: 0.121 Total Proposed Modified Loads: 26.26 PASS Total Baseline Loads: 29.74 I hereby certify that the plans and specifications covered by Review of the plans and -HE ST',q?� this calculation are in compliance with the Florida Energy specifications covered by this o Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY 41e Before construction is completed DATE: OA this building will be inspected for compliance with Section 553.908 " x4 1 hereby certify that this building, as compliance Florida Statutes. with the Florida Energy Code COD WG OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 11403.3.M. = Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.25 ACH50 (R402.4.1.2). 11/9/2018 3:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R4�5-2017 INPI IT CI IMMA92V I-U=1`Ll1 icT ouono-r PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: PEREZ GUEST RESIDENCE Bedrooms: 1 User Conditioned Area: 689 PEREZ Total Stories: 1 1 Worst Case: No Rotate Angle: 0 ST LUCIE COUNTY Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address ORANGE AVE & BRIDL St. Lucie FORT PIERCE, FL, - CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 689 6201 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infi11D Finished Cooled Heated 1 Main 689 6201 Yes 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 104 ft 0 689 ft2 ---- 1 0 0 ROOF / V # Roof Gable Roof Type Materials Area Area Color Rad Solar SA Emitt Barr Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 746 ft2 0 ft2 Light N 0.3 N 0.9 No 4 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 689 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 19 Blown 689 ft2 0.1 Wood 11/9/2018 3:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R4�)5-2017 INP11T RIIMMARV rN1=rk1 1QT Qcunc-r WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 N _ 2 E 3 S _ 4 W Exterior Concrete Block - Int Insul Main 4.1 28 6 9 0 256.5 ft2 2 0 0.8 Exterior Concrete Block - Int Insul Main 4.1 24 2 9 0 217.5 ft2 2 0 0.8 Exterior Concrete Block - Int Insul Main 4.1 28 6 9 0 256.5 ft2 2 0 0.8 Exterior Concrete Block - Int Insul Main 4.1 24 2 9 0 217.5 ft2 2 0 0.8 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 E Insulated Main None .4 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 3 E 2 Metal Single (Tinted) No 1.3 0.64 Y 54.0 ft2 8 ft 0 in 1 ft 0 in None S 3 Metal Single (Tinted) No 1.3 0.64 Y 22.5 ft2 2 ft0 in 1 ft 0 in None S 3 Metal Single (Tinted) No 1.3 0.64 Y 7.0 ft2 2 ft0 in 1 ft0 in None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0003 542.2 29.76 55.98 .109 5.246 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 16.4 kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 24 kBtu/hr 720 cfm 0.65 1 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.8 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 11/9/2018 3:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 1 a ,a FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin Jan Feb ((X Mar X] A r f Ma Jun f Jul [Xj Au rX Se X Oct X Nov jXj Dec Heating X Jan IX X Feb IX (X Mar X] APr May JX� XJun �XJul [X] Au[X� Sep f X� Oct f X� Nov [X] Dec 0 Ventin X Jan X Feb [[ Mar X A r May [X Jun X Jul [X] Aug [[[X]]] Se [X Oct M Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/s .ft. 0 ft2 Oft 0.3 Main 11/9/2018 3:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4