Loading...
HomeMy WebLinkAboutSewage1� STATE OF FLORIDA DEPARTMENT OF HEALTH P ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATIONS PERMIT #. APPLICANT: Francisco & Peggy Perez AGENT: Alexander J. Piazza PSM, Inc. LOT: na BLOCK: na SUBDIVISION: PROPERTY ID # : 2310-412-0002-000-7 [ Tax ID Number na TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [✓] YES [ ] NO NET USABLE AREA AVAILABLE: 5.00 ACRES TOTAL ESTIMATED SEWAGE FLOW: 767 GALLONS PER DAY [RESIDENCES -TABLE VOTHER-TABLE 2 ] AUTHORIZED SEWAGE FLOW: GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 1200 SQFT UNOBSTRUCTED AREA REQUIRED: 750 SQFT BENCHMARK/REFERENCE POINT LOCATION: ELEVATION OF PROPOSED SYSTEM SITE IS34 [INCHES/FT ] [ABOVE/BELOW'] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER:100 FT DITCHES/SWALES:15 FT NORMALLY WET? [ [ YES [✓] NO WELLS: PUBLIC:200 FT LIMITED USE:100 FT PRIVATE:75 FT NON—POTABLE:100 FT BUILDING FOUNDATIONS:5 FT PROPERTY LINES:10 FT POTABLE WATER LINES: FT SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [✓] NO 10 YEAR FLOODING? [ ] YES 1�/] NO 10 YEAR FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION : FT MSL/NGVD SOIL PROFILE INFORMATION SITE 1 MUNSELL #/COLOR TEXTURE DEPTH TO TO TO TO TO TO TO TO TO USDA SOIL SERIES: SOIL PROFILE INFORMATION SITE 2 MUNSELL #/COLOR TEXTURE DEPTH TO TO TO TO TO TO TO TO TO USDA SOIL SERIES: OBSERVED WATER TABLE:40+ INCHES [BELOW q EXISTING GRADE. TYPE:[ PERCHED/ APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: INCHES ABOVE BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ] YES [ ] NO MOTTLING: [ ] YES [ ] NO DEPTH: INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DRAINFIELD CONFIGURATION: [.�'] TRENCH [ ] REMARKS/ADDITIONAL CRITERIA: BED DEPTH OF EXCAVATION: INCHES [ ] OTHER (SPECIFY) igi a ysigne ,, D,:I =Una 811at2d,_er A01a4z2za7E0000016581 EE3C9600001981,—AlexanderAIQvander J Piazza am SITE EVALUATED BY: Dte:2019.01.3116.04:1645'00' DATE: 1-31-19 DH 4015, 12/11 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC Page 3 of 4 Unit Type of No. of No Establishment Bedrooms 1 RESIDENCE 4 2 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL° SYSTEM APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: New System [ ] Existing System [ ] Holding Tank [ ] Repair [ ] Abandonment [ ] Temporary PERMIT NO. DATE PAID: FEE PAID: RECEIPT #: [ ] Innovative [ l APPLICANT: Francisco & Peggy Perez AGENT: Alexander J. Piazza PSM, Inc. TELEPHONE: 772-340-7770 MAILING ADDRESS: 619 SW Biltmore Street, Port St. Lucie, Florida 34983 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: na BLOCK: na SUBDIVISION: na PLATTED: na PROPERTY ID #: 2310-412-0002-000-7 ZONING: R I/M OR EQUIVALENT: [ No ] PROPERTY SIZE: 5.00 ACRES WATER SUPPLY: [,/] PRIVATE PUBLIC [ ]<=2000GPD [ ]>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ No ] DISTANCE TO SEWER;.- FT PROPERTY ADDRESS: Orange Avenue, Fort Pierce, FL DIRECTIONS TO PROPERTY: SEE MAP BUILDING INFORMATION [v/] RESIDENTIAL [ ] COMMERCIAL Building Commercial/Institutional System Design Area Sqft Table 1, Chapter 64E-6, FAC 3,783 4 [ ] Floor/Equipment Drains Other (Specify) GARBAGE GRINDERS / DISPOSALS t Diaihllysia dby Alex &,J Pia Alexander J Piazza DN. N r—US, filie d owA07417E0W0016581EP3C96000019a1,cn=Alexan&rJ SIGNATURE: j Dec 2019.01.3116A0:33-0S'W DATE: 1-31-19 DH 4015, 08/09 (Obsoletes previous editi6ns which may not be used) Incorporated 64E-6.001, FAC Page 1 of 4 s STHATE OF FLORIDA • DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: Francisco & Peggy Perez . PROPERTY ADDRESS: TBD Orange Ave Fort Pierce, FL 34945 LOT: BLOCK: SUBDIVISION: PROPERTY ID # : 2310-412-0002-000-7 PERMIT #: 56-SF-1 927626 APPLICATION #:AP1400084 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT # : PR1207524 [SECTION, TOWNSHIP,,RANGE, PARCEL NUMBER] [OR'TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S-, AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH; -SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE- APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.. SYSTEM DESIGN AND SPECIFICATIONS T [ 1,350 ] GALLONS / GPD Septic new CAPACITY A [ ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ j GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ] D [ 834 ] SQUARE FEET Drainfleld new SYSTEM " R [ ] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ j STANDARD A ] FILLED [X] MOUND. [ ] I CONFIGURATION: [ ] TRENCH [X] BED [ ] N F LOCATION OF ,BENCHMARK: orange painted nail in fence post S of system I ELEVATION OF PROPOSED SYSTEM SITE [ 10.00][ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 6.00 ][INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT L , D O T H E R :=Lr, xsQaxxED: [GL.UU] INCHES EXCAVATION REQIIIRED: [ ] INCHES f00 he system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of , SPECIFICATIONS BY: Brian J Ingr TITLE: Environmental Specialist II c APPROVED BY: it— r^"^ —TITLE: Environmental Specialist II St. Lucie CHD Brian J Ingr io DATE ISSUED: 03/18/2019 EXPIRATION DATE: 09/18/2020 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 1 of 3 v 1.1.4 AP1400084 . SE1157285 NOTICE OF RIGHTS �� O A party whose substantial interest is affected by this order may petition for an administrative. hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency . Clerk's facsimile number is 850-413=8743. Mediation Js not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. � C AW HEALTH PAYING ON: -RECEIVED FROM: PAYMENT FORM: St. Lucie'County Health Department 5150 NW Milner Dr Port Saint Lucie, FL 34983 #: 56-SF-1927626 BILL ooc #:56-BID-4087241 CONSTRUCTION APPLICATION #: AP1400084 Alexander J. Piazza PSM, Inc AMOUNT PAID: $ 515.00 CHECK 156 PAYMENT DATE: 02/26/2019 MAIL TO:, Francisco & Peggy Perez FACILITY NAME: PROPERTY LOCATION: TBD Orange Ave Fort Pierce, FL 34945' Lot: Block: Property ID: 2310-412-0002-000-7 EXPLANATION or DESCRIPTION: 128 - OSTDS Construction System Inspection Research Fee -1 - Surcharge (All) -1 - OSTDS New Permit Surcharge -1 - OSTDS Construction Application and Plan Review,New 123 - OSTDS Construction Site Evaluation 126 - OSTDS Construction Permit (New or Mod, Amendment) 127 - OSTDS Construction System Inspection 133 - OSTDS Construction Reinspection QUANTITY FEE 1 $ 5.00 1 $ 15.00 1 $ 100.00 1 $ 100.00 1 $ 115.00 1 $ 55..00 1 $ 75.00 1 $ 50.00 RECEIVED BY: MontanezNM AUDIT CONTROL -NO. 56-PID-3865206 Q, STATE OF FLORIDA `j DEPARTMENT OF HEALTH = ONSITE SEWAGE TREATMENT AND DISPOSAL �.� SYSTEM APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: New System [ ] Existing System [ ] Holding Tank ( ] Repair [ ] Abandonment [ ] Temporary APPLICANT: Francisco & Perez PERMIT NO. 5f -� a,(Qa� DATE PAID: FEE PAID: 11V 0 RECEIPT #: wa::5, 0 [ ] Innovative AGENT: Alexander J. Piazza PSM, Inc. TELEPHONE: 772-340-7770 MAILING ADDRESS: 619 SW Biltmore Street, Port St: Lucie, Florida 34983 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: na BLOCK: na SUBDIVISION: na PLATTED: na PROPERTY ID #: 2310-412-0002-000-7 ZONING: R I/M OR EQUIVALENT: [ No ] PROPERTY SIZE: 5.00 ACRES WATER SUPPLY: [�/] PRIVATE PUBLIC [ ]<=2000GPD [ 1>2000GPD IS SEWER AVAILABLE AS PER 381.0.065, FS? [ No ]• DISTANCE TO SEWER: FT PROPERTY ADDRESS: Orange Avenue, Fort Pierce,FL DIRECTIONS TO PROPERTY: SEE MAP BUILDING INFORMATION Unit Type, of No Establishment 1 RESIDENCE 2 V—m I b oy C 3 5,—Vow- 4 [✓] RESIDENTIAL [ ] COMMERCIAL - No. of Building Commercial/Institutional System Design Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC 4 3,783 0 3 DO ] Floor/Equipment Drains [ ,/ ] Other (Specify) GARBAGE GRINDERS / DISPOSALS DiSiWly sipcd by Alcxund"j rime Alexander J Piazza ON:n=US,o-Umlfliuia,nu=AnIa27LOgXN1G5811i17C96000IYBI.rn=Aleandcl SIGNATURE: P,*— t)ule:2U19.n1A MA4ll.05-W DATE: 1-31-19 DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated 64E-6.001, FAC Page 1=of 4 0 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Francisco & Peggy Perez CONTRACTOR / AGENT: Alexander J. Piazza PSM. Inc LOT: BLOCK: SUBDIVISION: ID# : 2310-412-0002-000-7 APPLICATION # AP1400084 PERMIT # 56-SF-1927626 DOCUMENT # SE1157285 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 5.02 ACRES TOTAL ESTIMATED SEWAGE FLOW: 500 GALLONS PER DAY [ RESIDENCES -TABLET / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 12549.99 GALLONS PER DAY [ 1500 GPD/ACRE OR 1 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 2000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1250.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: Orange painted nail in fence post S Of ELEVATION OF PROPOSED SYSTEM SITE 10.00 [ INCHES / FT ] [ ABOVE / BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM.THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: .15 FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON -POTABLE: FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 5 FT POTABLE WATER LINES: 40 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD SOIL PROFILE INFORMATION SITE 1 SATT. PRAFTT.F. TWrnRMnmrnN eTTF 9 USDA SOIL SERIES:Riviera fine sand Munsell #/Color Texture Depth 10YR 5/1 Fine Sand 0 To 13 1 OYR 5/3 Fine Sand 13 To 26 1OYR 5/2. Fine Sand 20 To 26 10YR 7/4 Sand 26 To 41 10YR 5/2 Sandy Clay Loam 41 To 57 1 OYR 512 Loamy Sand 57 To 72 USDA SOIL SERIES:Riviera fine sand Munsell #/Color Texture Depth 10YR 4/1 Sand 0 To 14 1 OYR 5/2 Sand 14 To 24 1 OYR 5/1 Sand 21 To 29 10YR 7/4 Sand 29 To 40 1 OYR 5/2 Sandy Clay Loam 40 To 55 10YR 5/2 Loamy Sand 55 To 72 OBSERVED WATER TABLE: 72.00 INCHES [ ABOVE /BELOW ] EXISTING GRADE TYPE: ( PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 20 INCHES [ ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES [X]NO MOTTLING: [X]YES [ ]NO DEPTH: 20.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.60 DEPTH OF EXCAVATION: INCHES ,DRAINFIELD CONFIGURATION: [ ] TRENCH [XI BED [ ] OTHER (SPECIFY) r REMARKS/ADDITIONAL CRITERIA VT determined using USDA WSS and soil borings. t5/2 stripping in 10YR5/3 matrix >10% w/ diffuse boundaries starting at 20" in Sal. 10" below BM. S62 9" below BM. SITE EVALUATED BY: Ingram, Brian (TitlelEnvironmental Specialist II) (ENVIRONMENTAL HEALTH) DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC AP1400084 EID1927626 DATE: 03/05/2019 Page 3 of 4 v 1.0.2 STATE OF FLORIDA 'Y DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATIONS PERMIT #. �G�SF' iy27CoZ�G APPLICANT: Francisco & Peggy Perez AGENT: Alexander J. Piazza PSM, Inc. LOT: na BLOCK: na SUBDIVISION: na PROPERTY ID # : 2310-412-0002-000-7 [ Tax ID Number TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE;OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [✓] YES [ ] NO NET USABLE AREA AVAILABLE: 5.00 ACRES TOTAL ESTIMATED SEWAGE FLOW: 767 GALLONS PER DAY [RESIDENCES -TABLE I/OTHER-TABLE 2 ] AUTHORIZED SEWAGE FLOW: GALLONS PER DAY [ 1500 GPD/ACRE,OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 1200 SQFT UNOBSTRUCTED AREA REQUIRED: 750 SQFT BENCHMARK/REFERENCE POINT LOCATION: ELEVATION OF PROPOSED SYSTEM SITE IS34 [INCHES/FT ] [ABOVE/BELOW'] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER:100 FT . DITCHES/SWALES:15 FT NORMALLY WET? [ [ YES [✓] NO WELLS: PUBLIC: 200 FT LIMITED USE: 100 FT PRIVATE: 75 FT NON —POTABLE: 100 FT BUILDING FOUNDATIONS:5 FT PROPERTY LINES: 10 FT POTABLE WATER LINES:. FT SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [✓] NO 10 YEAR FLOODING? ( ] YES [,/] NO 10 YEAR FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION: FT MSL/NGVD SOIL PROFILE -INFORMATION SITE 1 MUNSELL #/COLOR TEXTURE DEPTH TO TO TO TO TO mn TO TO TO USDA SOIL SERIES: bul-L PROFILE INFORMATION SITE 2 MUNSELL #/COLOR TEXTURE DEPTH mn TO TO TO TO Tn TO TO TO USDA SOIL SERIES: OBSERVED WATER TABLE:40+ INCHES [BELOW r] EXISTING GRADE. TYPE:[ PERCHED/ APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: INCHES [,ABOVE/BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ] YES [ ] NO MOTTLING: [ [ YES [ ] NO DEPTH: INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DEPTH OF EXCAVATION: INCHES 7RAINFIELD CONFIGURATION: [./] TRENCH [ ] BED ( ] OTHER (SPECIFY) -2EMARKS/ADDITIONAL CRITERIA: uignal1111,"I'A....... ..— Alexander J Piazza DN;rUS.o UnafiBated.oU=A014DE0000016581EE3C9600001981.,n=Nezander SITE EVALUATED BY: 1P1a� Date zo,9.o,31,6oa:,6-asroo DATE: 1-31-19 )H 4015, 12/11 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC Page 3 of 4 5_&.- 5F_ /9 2 7CoZ co APPLICANT'S NAME: LEGAL DESCRIPTION: Francisco & Peggy Perez 2310-41 2-0002-000-7 r IN Z certify that there are no potable private wells within 75 feet of the available area for the proposed septic system, that there are no non -potable wells within 50 feet of the available area for the proposed septic system,. that there are no wells within 25 feet of a pesticide -treated building foundation; that there are no public wells that serve less than 25 people or less than- 15 homes or businesses within 100 feet of the proposed septic system, that there are no public wells that serve more than 25 people or more than 15 homes or businesses within 200 feet of the proposed septic system, that the water line from the water meter or well to the structure is at least t•0 feet from the available area for the proposed septic system unless the plans show the line to be double sleeved,. that there is not a gravity sewer line, low pressure sewer line or vacuum sewage line in a -public easement or right-of-way that abuts the property, that there are no lakes, streams, wetlands, or surface water within 75 feet of the available area for the proposed septic system unless the property was created prior to 1972, that the septic system is proposed on the side of the lot farthest from surface water, that all private wells, septic systems and surface .water on adjacent or contiguous land within 75 feet of the applicant's lot are shown on the site plan, that all public wells within 200 feet -of the applicant's lot are shown on the site plan, and that the location of building or residences, swimming pools, recorded easements, paved areas or driveways, sidewalks, the general slope of the property, filled areas, drainage features, and surface waters such as lakes, ponds, streams, canals, or wetlands are shown on the applicants lot. The natural grade elevation in the area of the. proposed septic system and the benchmark must be shown on the site plan. Please. locate the benchmark within 200 feet of the proposed septic system. NOTE: MUST BE CERTIFIED BY A FLORIDA REGISTERED SURVEYOR OR ENGINEER. DgIPollysigned by IL, W. ml Plaaa Alexander J Piazza °"` '�'�' ou=AQ142dE DI65BIEF3C9600001981, Al CERTIFIED BY. Date 2019D73116.U256-05W FLORIDA PROFESSIONAL NO.: 6330 DATE: 01 /31 /19 16D NO.: 17-3366 dots/ro rms/septics/Sep ti cAppp Page207 APPLICANT'S NATME: Francisco &Peggy Perez LEGAL DESCRIPTION: 2310-41,2-0002-000-7 I certify that there are no potable private wells within 75 feet of the available area for the proposed septic system, that there are no non -potable wells within 50 feet of the available area for the proposed septic system,. that there are no wells within 25 feet of a pesticide -treated building foundation; that there are no public wells that serve less than 25 people or less than- 15 homes or businesses within.100 feet of the proposed septic system, that there are no public wells that serve more than 25 people or more than 15 homes or businesses within 200 feet of the proposed septic system, that the water line from the water meter or well to the structure is at least 10 feet.from the available area for the proposed septic system unless the plans show the line to be double sleeved,. that there is not a gravity sewer line, low pressure sewer line or vacuum sewage line in a public easement or right-of-way that abuts the property, that there are no lakes, streams, wetlands, or surface water within 75 feet of the available area for the proposed septic system unless the property was created prior to 1972, that the septic system is proposed on the. side of the lot farthest from surface water, that all private wells, septic systems and surface water on adjacent or contiguous land within 75 feet of the applicant's lot are shown on the site plan, that all public wells within 200 feet of the applicant's lot are shown on the site plan, and that the location of building or residences, swimming pools, recorded easements, paved areas or driveways, sidewalks, the general slope of the property, filled areas, drainage features, and surface waters such as lakes, ponds, streams, canals, or wetlands are shown on the applicants lot. The natural grade elevation in the area of the. proposed septic system and. the benchmark must be shown on the site plan. Please locate the benchmark within 200 feet of the proposed septic system. NOTE: MUST BE CERTIFIED BY A FLORIDA REGISTERED SURVEYOR OR ENGINEER. ( D111ft1 19i dbyAlexaedel7— Alexander J Piazzakou=AVI4]7E000OO1I6581EE3C9680001981, CERTIFIED BY: !,f .'Date 1201901.31 16.03L"5'00' FLORIDA PROFESSIONAL NO.: 6330 DATE: 01 /31 /19 JOB NO.' 17-3366 does/forms/sep tics/SepticAppp Page207