Loading...
HomeMy WebLinkAboutSite PlanSIC Lr) m i 0� NEW GUEST HOUSE RESIDENCE <.. =•t� ;,,ar rtz w�c_n ,":".a� '�,*:,. Fan a r, ��"� �`�. an-,,, r fig,. ,:�-. .�'.�- .�P., a� .'.:. ,. BRIDLEWOOD WAY AND ORANGE AVENUE FORT PIERCE, ST LUCIE COUNTY, INDEX OF DRAWINGS w SITE PLAN ARCH/RF/F❑UND/ELECT PLANS BLDG ELEVATI❑NSI & DETAILS PROIDUC-r APPROVAL SUE3MlY"rAL.. GENERAL INFORMATION INSTALLATION METHOD STATIC PRESSURE DESIGN PRODUCT WIND STORM PRTCTN MARK PRODUCT MODEL # MANUFR. PRODUCT APPROVAL GLAZING ATTACHMENT (+) 0 (+) 0 1O SINGLE HUNG YAWS SH-7700 LAWSON 17-1212.21 1/4'LAM GL 1/4'TAPCONS 0 ALL MFR'S HOLES W/ 1.7SEMBED - +801-80# +49.2#,-53.71 IMPACT OA 3068 STL DOOR CONTOURS STL JELD-WEN FL14569-RIO N/A HD & SILL 3/16-TAPCONS @ MAX 6' FROM CORNERS MAX 12'0.C. SPACING FOR REMAINING i JAMBS: MAX 6" FROM CORNERS MAX 18' D.C. SPACING (STAGGERED) +50A-60# +49.4#, 53.8# IMPACT PRODUCT MODEL # MANUFR. ATTACHMENT PRESSUREPRODUCT WOW & DR FLASHING VULKEM 35ONF TREMCO, INC BRUSHED ON MASONRY OPNG INSDE & 6-ONTO FACE OF WALL N / A -440 PSF METAL ROOFING MART LINE SUNLAST MTL #10 FASTENERS - 12'O.C. FIELD & 6-O.C. PERIMETER/ �RNER -84.3# HELD -136.7# P&C SIDING N /A N /A N /A N /A N/A SOFFIT STUCCO N/ A N/ A N/ A N/ A 1 HAVE REVIEWED THE ABOVE INFORMATION & APPROVED IT: ARCHITECT: JAMES E GILGENBACH FL AR7457 SIGNATURE: DATE: t {, I I� STUDOR VENT 1 3„ V.T.R. I f K SINK W/ DISP I <1 1 1/2" STUDOR VENT LAV C.O. C.O. 1 1 4 / W TUB r.I 2„ 2 Q C.O. �y 3" 3" W Z„ 2„ W.C. 3" / 3" /r C.O. OUTSIDE TUB �V( BLDG. LINE 2" 4„ 4" SAN. LINE TO ' NEW SEPTIC SYSTEM 4" (SEE SITE PLAN) PLUMBING RISER NO SCALE PLUMBING NOTE: ALL BATHROOMS & CAB. BA. TO HAVE FLOORS PROVIDE 'A TISCALD' VALVES @ ALL TUBS & BASES OF TILES OR OTHER IMPERVIOUS & SHOWERS MATERIALS A WATER HAMMER AR STOR SHALL BE INSTALLED FIRESTOP ALL PLBG. PENETRATIONS OF THE WHERE QUICE-CLOSINP VALVES ARE UTILIZED / FIRE RATED GARAGE WALLS OR CEILING WITH WASHER MACHINE / SHWASHER-AREA, PROVIDE '3M' (OR EQ) FIRE BARRIER PRODUCTS ANS ACCESS To WATER HAMMER ARRESTORS. APPLIED AS PER MFR'S. SPECIFICATIONS. STEEL STUDS SUPPORTING WALL HUNG PLUMBING WATER HEATER WILL BE PROPANE TANKLESS FIXTURES SHALL BE DOUBLED OR NOT LESS CONTINUOUS FLOW UNIT THAN 20 GAGE WITH � MIN. EFFECTIVE MOMENT ALL PLBG. FIXTURES TO COMPLY W/ TBC' OF INERTIA EQUAL TO 0.864 IN.4(360 M4) PLUMBING TABLE: 604.4 TUB & SHWR.IWALL TO BE NON -CORROSIVE TABLE 704:1 SLOPE OF HORIZONTAL DRAIN PIPE SIZE (INCH) MIN SLOPE (IN/FT) 2-1/2 OR LESS 1/4 3 TO 6 1 /8 8 OR LARGER 1/16 IMPERVIOUS MATERIALS MIN. 6' ABOVE RM. FLOOR WATER PIPING TO BE 'UPONOR PEX' PIPING FLORIDA LEGAL DESCRIPTION: COMMENCE AT THE NORTHEAST CORNER OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 10. TOWNSHIP 35 SOUTH, RANGE 39 EAST, THENCE RUN SOUTH 89'49'45" WEST, ALONG THE NORTH LINE OF THE SOUTHEAST QUARTER OF SA1O SECTION 10, A DISTANCE OF 620.93 :FEET; THENCE RUN SOUTH 00"04'54" WEST, A DISTANCE OF 72.00 FEET, TO'A HALF INCH IRON ROD AND CAP STAMPED RLS 2391 AND THE POINT OF BEGINNING, THENCE CONTINUE SOUTH 00'04'54" WEST. A DISTANCE OF 358.48 FEET. TO A HALF INCH IRON ROD AND CAP STAMPED RLS 2391; THENCE SOUTH 89'56 24" WEST, A DISTANCE OF 504.31 FEET, TO A HALF INCH IRON ROD AND CAP STAMPED RLS 2391; THENCE RUN NORTH UG'00'05" WEST, A DISTANCE OF 97.76 FEET, TO A HALF INCH IRON ROD AND CAP STAMPED RLS 2391; THENCE RUM NORTH! 00'34'2E3" WEST, A DISTANCE OF 100,00 FEET, TO A HALF INCH IRON ROD AND CAP STAMPED RLS Z391; THENCE RUN NORTH 04'00'20"WEST, A DISTANCE OF 100 24 FEET, TO A HALF INCH IRON ROD AND CAP STAMPED RLS 2391: THENCE RUN NORTH 02'49`49" WEST, A DISTANCE OF 60,78 FEET, TO A HALF INCH IRON ROD AND CAP STAMPED RLS 2391; THENCE RUN NORTH 69'56'24" EAST ALONG THE SOUTH RIGHT-OF-WAY OF ORANGE AVENUE, A DISTANCE OF 615.82 FEET, TO A HALF INCH IRON ROD AND CAP STAMPED RLS 2391, AND THE POINT OF BEGINNING, ALL LYING IN SECTION 10, TOWNSHIP 35 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA. CONTAINING: 217,802'SQUARE FEET OR 5,00 ACRES MORE OR LESS ORANGE AVENUE - --- - GUEST HOUSE RESIDENCE SCOPE OF WORK: NEW ONE STORY GUESTHOUSE RESIDENCE 13UILDING CODE INFORMATION' , ARCHITECT: JAMES E, GILGENBACH (FL AR7457) WIND DESIGN STANDARD: ASCE 7-10 BUILDING CODE; FL BLDG CODE 2017, 6TH ED, ELECTRICAL CODE: NATL ELECTRICAL CODE 2014 (NFPA 70) DESIGN WIND SPEED: ULTIMATE-170 MPH NOMINAL-132 MPH DESIGN WIND VELOCITY PRESSURE: 41.1 PSF IMPORTANCE FACTOR: 1.0 BUILDING OCCUPANCY CATEGORY: II' BUILDING WIND EXPOSURE CLASS: 'B' INTERNAL PRESSURE COEFFICIENT: +/-.18 MEAN ROOF HEIGHT FROM GRADE, 11.0 FT, BUILDING DESIGNED: ENCLOSED IMPACT PROTECTION: 'IMPACT' GLAZING BLDG OCCUPANCY CLASSIFICATION: R-3 (SINGLE-FAMILY) BLDG TYPE OF CONSTRUCTION: TYPE V BLDG - TOTAL # OF STORIES: 1 STORY BLDG. ROOF OVERHANG & PITCH' 24' OVRHG & 5/12 PITCH ROOF DEAD LOAD: SHT METAL / 5 PSF LANDSCAPE / c LY N NO TH , IRRIGATION NOTES: �- ALL LANDSCAPED AREAS AS SHOWN ON THE LANDSCAPE PLAN SHALL BE FULLY IRRIGATED S C A L E: 11' = 30'— 0" $Y MEANS OF A AUTOMATIC (TIMECLOCK CONTROLLED) IRRIGATION SYSTEM CONFORMING - TO ALL LOCAL CODES INCLUDING SOUTH FLORI➢A WATER MANAGEMENT DISTRICT 'XERISCAPE' PLAN PUIDE. II. PLL PLANT MATERIALS TO CONFORM TO STANDARDS FL13RIDA #1 OR BETTER AS GIVEN IN GRADES / (r �F STANDARDS. VQ� SOD IST AUGUSTINE FLORITAM GRASS HC U 5 4 \god-oGo� V 1 z W�W W 6 �Cwh O W 2� I �U77 U x �a E E-4 d � NA � O o W 4 IL run) o p 10 (Y) U I--1 II GATE: m M K 4 22 SEP '18 Q L v 0 PROJECT NO: *li �. L3c& M GENERAL CONSTRUCTION NOTES: 1. ALL WORK BY ALL TRADES TO BE COMPLETED INACCORDANCE NTH ALL APPLICABLE, LOCAL, & GOVERNMENTAL CODES, ORDINANCES, STANDARDS AND RESTRICTIONS. 2. ALL. TRADES TO COORDINATE THIR WORK WITH ALL OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 3. CONTRACTOR TO VERIFY ALL DIMENSIONS ON THE JOB PRIOR TO COMMENCING CONSTRUCTION AND NOTIFY ARCHITECT OF ALL DISCREPANCIES. DIMENSIONS ALWAYS TAKE PRECEDENCE OVER SCALED DRAWINGS 4. ALL DIMENSIONS ARE NOMINAL TO THE FACE OF STUDS, CONIC. BILK. OR EDGE OF MONOLITHIC SLAB FOOTING UNLESS NOTED OTHERWISE. DOOR AND WINDOW SIZE OPENINGS. TO BE VERIFIED WITH THE MANUFACTURER. 5.ITIS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION, THE CONTRACTOR IS EXPECTED TO FURNISH & INSTALL ALL ITEMS FOR COMPLETE FULLY OPERATIVE SYSTEMS IN FIRST CLASS WORKMANLIKE MANNER. 6. INSULATE EXTERIOR MASONARY WALL WITH.MIN. R-4.1 INSUL., EXTERIOR WD. FRAMED WALLS WITH R-19INSUL. & FOAM ATTIC SPACES W/ R-20 OPEN CELL FOAM 7. COMPACT ALL FILL TO A MIN. OF 95% DENSITY AND POISON SOIL FOR TERMITES; .MIN. SOIL BRG.: 2500 P.S.F. 8. MIN: CONC. STRENGTH: 3000 P.S.I. ® 28 DAYS. MIN. CONCRETE COVERAGE FOR 4• BEAMS & COLS: 1 1 2• TIE COLS: 3 REINF. BARS. SLAB: 3/""/4 FORMED / CONC. BELOW GRADE: 2" & UNFORMED. CONIC.: 3". 9.. REINFORCING STEEL TO BE GRADE 60. 10. DETAILS OF CONCRETE REINF. SHALL BE IN ACCORDANCE WTH "THE MANUAL OF STD. PRACTICE FOR REINFORCED CONCRETE CONSTRUTION". 11. TIE COLUMNS TO HAVE DOWELS INTO CONCRETE FIG. WITH THE SAME SIZE AND NUMBER OF DOWELS AS VERTICAL REINF. BARS.; REINF. STL. TO BE LAPPED 30 BAR DIAM. MIN. 0 SPLICES. 12. PROVIDE CLEANOUT OPENINGS AT THE BOTTOM OF GROUTED CELLS OF CONCRETE BLK. TIE COLUMNS. 13. ALL WOOD IN CONTACT WITH. CONIC., MASONRY OR STL SHALL BE PRESS. TRTD. WD. STRUCTURAL LUMBER TO BE A STRESS GRADE OF MIN. F = 1200. PSI (BENDING). 14. MIN. ELECTRICAL WIRE SIZE SHALL BE #14 A.W.G. (EXCLUDING THE CONTROL WIRING). ALL CONDUCTORS SHALL BE "COPPER" WITH "THHN" INSULATION. 15. ALL RACEWAYS UNDERGROUND OR LARGER THAN 2" IN DIAM. SHALL BE GALVANIZED RIGID STL CONDUIT OR SCHED. 40 PVC.; OTHER RACEWAYS AS PER CODE. REQRMTS. 16. PROVIDE "GFI" RECEPTACLES IN BATHROOMS, AT KITCHEN COUNTERS, IN GARAGE AND OUTSIDE. LOCATIONS. 17. SANITARY PLBG. PIPING TO HAVE MIN. 1/8"PER FT. PITCH AT ALL HORIZ. RUNS. PROVIDE CLEANOUTS AT THE BASE OF WASTE STACKS. 18. ALL UNDERGRD. WATER PIPING SHALL BE COPPER TYPE "K;. ALL OTHER WATER PIPING SHALL BE COPPER TYPE "L 19. PROVIDE AIR CHAMBERS AND SHUT OFF VALVES FOR ALL WATER SUPPLY PIPING AT FIXTURES; PROVIDE VACUUM BREAKER AND SHUTOFF VALVE ON ALL HOSE BIBBS.-.. 20. A/C AIR HANDLING UNITS TO HAVE CONDENSATE SAFE WASTE WITH TRAP. CONDENSING UNITS 216- COND UNIT TO. BE SECURED TO CONIC. BASE WITH (4) 1"W X 6"LNG WA GALV REFRIG. LINES MTL STRAPS W(2) GALV SHT MTL SCRWS - TO UNIT & NI BA PDR DR. PIN INTO CONIC BASE.. A/C COMP ON MIN 4" CONIC PAD FIN FLUSH W/ EXIST BLDG U. CONDENSING UNIT MOUNTING DETAIL S C A L E: 3/4' - 1'-W A/C EQUIPMENT: MINI -SPLIT SYSTEM "GREE MULTI" COND: MULT124HP23OV1AO SEER: 16.0 SEER COOLING: 26,000 BTUH A.H.U.: (2) NEO UNITS WIND RESISTANCE CALC FOR FOR A/C COMP : ( 46#,42#) WINDOW GLAZING C PROVIDE PGT WINGUARD WHITE LUMINUM ' ELECTRIC SYMBOLS 'APPROVED' IMPACT GLAZING IFOR TALL GLAZED OPENINGS IN EXTERIOR WALL W/ WALL MTD. RECEPTACLE �p PUSH BUTTON IMPACT RESISTANT WOWS. & RS. S PER F,B.C. SECTION #1606 ® 240V. RECEPTACLE J JUNCTION BOX SPECIAL PURPOSE o GLAZING TO BE TINTED (ENERGY .CALCS) CEILING FAN (CONTRACTOR RESPONSIBLE T VERIFY ROUGH OPNG. � INCAND. LITE FIXTURE .OUTLET SIZE W/ WOW. MFG, INSTALLATION INSTRUCTIONS) RECESSED INCAND. "HI -HAT" � (J-BOXONLY) ALL EGRESS WOW, OPNGS, TO BE MIN. 24-HI & 20- PHONE JACK LOCATION WIDE AND MIN. 5.7 S.F. OF OPNG. EXHAUST FAN 4 T.V. JACK LOCATION H,q WALL MTD. SWITCH REINF. MASONRY STANDARD: SMOKE DETECTOR SURFACE MTD. SD (120V & BATT. BACKUP) x FLUORESCENT THE PROVISIONS OF ACI 530-0 I /ASCE5-05 BUILDING CODE REQUIREMENTS FOR MASONRY S"RUCTURES,& THE COMMENTARY ON BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES ARE HEREBY ADOPTED AS N O T E S THE MINIMUM STANDARD FOR THIS JOB. HOWEVER':. THIS SHOULD NOT SUPERSEDE ANY REQUIREMENTS FOR HIGH ARC -FAULT CIRCUIT INTERRUPTER ON ALL SINGLE VELOCITY HURRICANE ZONES REINF. UNIT MASONRY PHASE 15 & 20 AMP BRANCH CIRCUITS EVERYWHERE EXCEPT GFI RECEPTACLES ® BATHROOMS,KITCHENS, GARAGES & OUTSIDE RECEPTS. BEAM DESIGNATI N: ALL RECEPTS. TO BE "TAMPER -PROOF" AS PER NEC 2008 SEC. 406.11. COMPOSITE REINFORCED CONCRETE BEAMS USING PRECAST AND PRESTRESSED CONC. LINTELS ('CAST-CRETE' ORE .) & STD. CONCRETE MASONRY UNITS NOMINAL HGT, NO. OF #5 BARS AT NOM, WIDTH �EIOTTEIM OF LINTEL . 8F16-1B/1T F=FILLED NO. OF #5 BARS AT U=UNFILLED TOP OF'. BOND BEAM TRUSS ANCHORAGE ROOF LOADS TCLL: 20 PSF TCDL: 15 PSF BCLL 10 PSF BCOL.- 10 PSF TOTAL:- 55 PSF OTRUSSANCHOR A GALV. MTL.RIVETED TRUSS O.(6)IOD COMMON NAILS -TRUSS Fl=34 X 1 1/2 NAILS =-1!5 F1=340#, F2=725#, U=-1 ROOF SHEATHING NOTE: ROOF SHEATHING TO BE MIN. 5/8 , PL 50# TOMPSON" FOUNDATIONS Lc SCE" 'I 16"DP X 18"W MONOLITHIC CONCRETE FOOTING W/ (2)#5 REINF BAR CONT. O 10" DP. X 8" W. THICKENED CONCRETE SLAB EDGE 11, COX W/ (1)#5 REINF. BAR CONT. O EXP. PLYWD. W/ LNG. DIM. PERPENDICUL R TOFRMG. & END JNTS. STAGGERED, ROOFS ATTACHED WITH 80 COMMON NAILS TG. TO AT 6" BE FOUNDATION NOTES. O.C. AT EDGES AND INTERMEDIATE FRAMI G. NO ZONE 3 (GABLE END) FLOOR SLAB: 4" CONIC. SLAB W/ 6X6-10/10 W.W.M. ON 6 MIL. POLYETH. VAPOR BARRIER ON COMPACTED TERMITE POISONED FLAME SPREAD & SMOKE INDEX: CLEAN FILL. MIN. SOIL BEARING: 2000 P.S.F. MIN. CONIC. STRENGTH: 2500 P.S.I. AT 28 DAYS LAME WALL & CEILING FINISHES TO HAVE SPREAD INDEX TYPICAL TIE COL.: (1) #5 REINF. BAR' VERT. & GROUTED OF NOT GREATER THAN 200. WALL & CEILING FINISHES TO HAVE MOKE.-DEVELOPED( 1 SOLID IN CELL OF CONIC. BLK. WALL W CONCRETE. / INDEX OF NOT GREATER THAN 450. TESTS TO BE MADE IN ACCORDANCE WITH �'. ASTM E84 OR 1 1/2" OP. X 8" W. WATERSTOP RECESS ALL AROUND HOUSE UL 723 OR ALTERNATIVE METHOD OF SECTION R302.9.4. PERIMETER UNDER CONIC. BLK. WALLS TRUSS BRC. EL 9'-0' a a - g - g g g - . -Q =-Q - ¢ - Q ¢ I I Q -I r I I I I I I I I I I`I I I I I I II l IQI I II �I I IQI... II II 9'-8' 4'-10' 9'-8' II a I I la m m I I i 17 a I- -I WD ROOF TR SES @ 2 OC / TRUSS MFR. TO PR IDE ENGIN. SH D WGS FOR I --APPROV & BLD_DEPT. SU ITTALS - Q_ 1 I I I Q � IQI II--rram ---- --- -- I ------ IQI IQI I I I I I I I III I I I TRUSS BRC. EL 9'-0' ROOF PLAN S C A L E: 1 /4" = 1'- NORTH AREA CALCS: LIVING: 689' S.F. ENTRY: 145 S.F. TOTAL: 834 S.F. DISCONNECT SWITCHES 200AMP (3)#2/0 THHN-CU HOUSE IN 1 1/2' COND TO 400A MAIN DISC O 0 HOUSE 200A PANEL SERVICE PANEL 100AMP (3)#3 THHN-CU (LOCATED AT MAIN 0 =GUEST IN 1 COND TO RESIDENCE GARAGE) 10 300AMP GUEST 0A PANEL 400A CD GARAGE (3)#350 THHN-CU 120/24OV !, IN 2 1/2' COND TO SPH GARAGE 300A PANEL BURIED MAIN FEEDER FROM TRSFRMR. (SEE LOCATION ON SITE PLAN) FROM FPL #2 CU TO C.W.P. SUPPLY & FIG. REBAR. -(2) 5/8'X10' CU (3)#400 MCM-CU J-L CLD. GRID, ROD IN 3'D COND. _ _ 10' APART ELECTRICAL RISER NO SCALE (SERVIC(AT MAIN RESIDENCE) LOAD CALCULATIONS: MAIN HOUSE 200A PNL =, %7 KW GUEST HOUSE 100A PNL =, 26.2 KW DETACHED GARAGE 300A PNL =, 100.0 KW TOTAL PANELS LOADS = 216.9 KW FIRST 10 KW. @ 100% 10.0 KW REMAINDER @ 407 = 68.4 KW HEATING @ 657 _ 14.3 KW 92.7 KW 10,000 AMP PANEL "GH" io A,N120/240V, IPHS LITES & RECPTS* 2.1 KW 15A/IP (2)#14THHN DISPOSAL 1.0 KW 20A/1P (2)#12THHN REFRIG, 1.2 KW 20A/1P (2)#12THHN DISHWHR 1.0 KW 20A/1P (2)#12THHN SMALL APPL,(2) 3.0 KW 2OA/1P (2)#12THHN MICROWAVE 1.2 KW 2OA/1P (2)#12THHN DRYER 4.5 KW 3OA/2P (3)#10THHN WASHER 1,5-KW 20A/1P (2)#12THHN UTIL, G.F.I. 1.5 KW 20A/1P (2)#12THHN DINING RECPTS 1.5 KW 20A/IP (2)#12THHN EXT GFI RECEPT 1.2 KW 20A/11P (2)#12THHN MINI -SPLIT A/C 2.0 KW 20A/3P (3)#12THHN WATER HTR 4.5 KW 25A/2P (3)#IOTHHN 26.2 KW TOTAL CONN. LOAD FIRST 10 KW. @ 100% = 10.0 KW REMAINDER @ 40% = 5.7,, KW A/C LOAD @ 1007 = 2.0' KW 17.7 KW *(689 SF X 3W = 2067 KW) - 240V 74 AMPS. ,_9' _ 5'-2' - 4'_3- - 4' 4' 3' 'OUND ION PLAN C A L E: _ 1 /4" = 1`-0" VENT DRYR THRU MINI -SPLIT A/C WALL W�SMOOTH W.P. MTL DUT jL G,FI MINI -SPLIT AHU STK. GFIf: V.P. BEDROOM W 9' CLG n 77 za. I II ,9 TCILo(3l WO P)D I I \BATGH W.H.. GFI CLOSET SD 36"LG�I TTTe. ACC sS / - - _ - - UTI MP rj1F?E0 CT PNL I MINI-SPUT AHU P.C. LITE IN ATTIC / I IREFRIG I \ I I n _ C_4 �� I I I I) WEPBAR 9 FI I LIVINGI'ROOM a I zo dG I 9' CLG � rn Y� q / I GFI -�--- I I �� I COVERED ENTRY PORCH ❑-------- ❑ -- ------ ❑--- ----- ❑ I IN 100AMP DISC SW FOR GUEST HOUSE ELECT qq SERVICE FED C7'FROM THE W.P. MAIN HOUSE G.F.I.SERVICE -IF H.B. ELECTRICAL FLOOR PLAN FILE COPY S C A L E: 1 /4" = 1'-0" P117111Ei p�D FOR/a 24'-2'. CV DEC ``oM LBy`,�"ag�N�� CE 1, IXtAVMGS ARE fA`^ ONS 6'-4- 17'-10' 4T, WU 9 UNTY SCALED. EC DEN(TTEN ROVER ALL HAVE PRECEDENCE OVER ALL SCALER DIMENSIONS, MINI -SPLIT A/C 2 CONTRACTOR N VERIFY ALL (-53.5I ,SS) I I OF ANY D & ADVISE ARCHITECT 3. ESS OF ANY DISCREPANCIES. 0 CENSTRUCTDW Will NOT PROCEED 35 S.Hi. WDW LINTD. SAID DISCREPANCIES HAVE • LLI Co 01 Z r � . CC I- o �ma O� ; an L ( REVISIONS' REV: 07 OCT' BLDG DEPT C01, El i11 p p p p 1 T r 1DT T 1GI ao 8F16-1T/18 _ Y _ m ❑ 3 o v - m UTIL s _ z 9,-4„CLG F uNi _ 11'-4' i0 4', 5'-10' 4' S W.C. 7 _ o - BEDROOM 2880 BATH -_ 9'-4"CLG -. PKT DR 9'-4" CLG -_ _ "4._ fU W.H. m� - 2880 - _ WD DR m �. - - 5080 I BI-FLD o� - 3s"Lc HALL I 0 1 "EATTW,i CLOSET NmI:,ACCESS 2860 9'-4" CLG I MTL DR CI - - in - - - - - - - UTI (-53.80,4 . #) m l :n03 _ a a B. _ 9' 4- 2'-4- 3' 4' 7'-10' I - - IREFRIG - = o I zo _ o M _ 22'-10' I - 8' El o LIVING ROOM 'P WET BAR II J - _ m 9'-4" CLG 9'-4" CLG T CO v - - xa z� zn- - O - 8F16-1T/1B 8F16-1T/1B 8F16-1T/1B I - 34 S: . WDW 3080 34 S.F. WDW (-65.-#,49.8#) MTL OR (-65.3 ,49.8#) 3.4#,49.0 I 8-W X 16 DP CONC LINTEL/ 8'W X 16'DP CONC LINTEL/ I BOND BF1. W/ (1)#5 BARS BOND BM. W/. (1) 5 BARS ih 20 TOP &I OTT. TOP & BOTT. I COVERED ENTRY PORCH T'111 4'-3- 6' 2,.. 3'_4' 6'-2' 4'- -----_- 11 __-.----- m----.--- F.. 1YRS COL "O.C. & #SW#a 82"OSC.. 12"X12// CONIC BILK COL & #3 'n�4S 5 B2 ffS . ARCHITECTURAL FLOOR PLAN S C A L E: 1/4" = 1'-0" BEEN RESOLVED BY ARCHITECT. a fa N4IERIAIS OR SYSTEMS ARE TO BE FABRICATED UITILs A ALL DDENSIDMS HAVE BEEN VERFIED BY TIE CONTRACTOR. B. SHOP DRAWINGS HAVE BEEN REVIEWED & ACCEPTED BY THE ARCHITECT. �r DATE: 22 AUG '18 PROJECT, NO: 17 - 9117 SHEET: of 3 A2 NORTH STANDING SEAM METAL RF. ON 30# FELT W/ PEAL & STICK ON 30# FELT TINTAGGED ON 5/8' COX PLYWD. SHTG, ON WD, RF. TRUSSES @ 24' O.C. (MFR. TO PROVIDE ENGINRED SHOP DRWGS. 12 �5 D. BRACING SEE TRUSS DRWGS.) GALV. MTL. DRIP EDGE ON 1X2 P.T. WD. STRIP & 2X8 WD FACIAS STUCCU. ON GALV MTL LATH GALV. MTL. ANCH. STRAP h` @ EACH TRUSS 8'W X 16'DP CONC LINTEL/ II BOND BM. W/ (1)#5 BARS II 24' TOP & BUTT. II II STUCCO ON GALV. MTL. LATH W/ 6' X 16' SCRND. VENTS @ TYP. COL 12'X12' CONC BLK W/(2)#5 REINF. II BARS VERT. & GROUTED SOLID IN CELL OF CONC. II BLK. WALL W/ CONC. II II II II REINF. CONCRETE FLR. (SEE FOUND. NOTES ON II - FOUNDATION PLAN) II PORCH FLR. EL . I I I —III . •` , �r __ -III III I •�<• �•, t—,� II —III _—I_—_ _- -1 I I —I I I-1 �: '• �'� •. a III —III I1 I-1 I I-1 I I-1 11= PORCH S C A L E: SECTION 3/4" = 1'-O" STANDING SEAM METAL RF. 00 IN 3 # FELT W/ PEAL & STICK ON 30# FELT TINTAGGED ON 5/8' CDX PLYWD. SHTG. ON WD. RF. TRUSSES @ 24' O.C, (MFR: TO PROVIDE ENGINRED SHOP DRWGS. ,12. 5 GA V. MTL DRJP EDGE ON RF. TRUSSES @ 24' D.C. 2X P.T WD. STf IP 24' 5/8' T&G PLYWD SIDING FACE IOWN 2X4 WD. BLK. @ 16' 1 ,C, W/(2)16d NAILS @ EA TRUSS MIN 7/8' THK STUCCO TRUSS TO TRUSS N GALV MTL P PER- K _. CONNECTORS SEE LATH. ON 5/8' T IK. TRUSS MFR DWGS COX PLYWD SHTG. GALV 2X4 WD BLKG BETW TRUSSE RF. TRUSSES @ 24 D.C. CUPOLA DETAIL LD S C A L E: 3/8" = 1'-0" ICYNENE INSULATION NOTE III ICYNENE INSULATION WILL BE OPEN CELL FOAM INSULATION NO IGNITION BARRIER IS REQUIRED AS THE FOAM INSULATION METAL ROOF WILL BE TESTED IN ACCORDANCE WITH SECTION R316.6. ACCE S PANEL TO ATTICWILL BE FOR PURPOSES OF MAINTENANCE & REPAIRS. LOUVER CLOSED INSIDE ATTIC W/ 5/8" .PLYWD. METAL ROOF. 12 5 FELT G TAL PEAL & ES STICK ❑N030#O TW FELT TINTAGGED ON 5/8' COX PLYWD. SHTG, ON WD. RF, TRUSSES @ 24' ❑,C, (MFR. TRuss BRc TO PROVIDE ENGINRED SHOP DRWGS, EL. 9'-4" A.F. . 12 ' P.T. IX2 WD, FIRESTOP 5 FURRING STRIP CONT. AT TOP OF WALL BELOW CLG. LINE & @ BOTT. OF WALL - SEE TRUSS DRWGS.) '.. D. BRACING GALV. MTL. DRIP EDGE ON IX2 -I•- `" P.T. WD. STRIP 11 & 2X8 WD. STUCCO FINISH ON R-30 ATTIC INSUL, FACIAS. 8' CONC. BLK: WALL. 5/8' GYP. BD. CLG. GALV. MTL. ANCH. TYP. FIN. FLR. STRAP @ EACH * ` EL. 0'-0" TRUSS. 8'W X 16'DP CONC LINTEL/ BOND BM. W/ (1)#5 BARS TOP & BUTT, 24' I.r'i.y.I.y LEFT SIDE ELEVATION STUCCO ON GALV. MTL. LATH W/ 6' X 16' SCRND. VENTS @ i I S C A. L E: 1/4" = 1'—O'. 8'-0' O.C. . • ;_-- CUNT.URRING STRIP `.AID HGT OF WALL MAX. �� 1/2' GYP. BD. ON IX2 P.T. WD, FURRG STRIPS I @24' D.C. R-4.1 RADIANT BARRIER INSUL. BETW. FURRG. I STUCCO ON 8' CONC. STRIPS BLK. WALL P.T. IX2 WD. FIRESTOP ( _ FURRING STRIP CONT. AT #9-TRUSS-TYPE HORIZ. TOP OF WALL BELOW CLG, I MASONRY JOINT REINFMT. LINE & @ BUTT. OF WALL, I AT EVERY SECOND COURSE WD, BASE (TYP) REINF. CONCRETE FLR: (SEE FOUND. NOTES ON FOUNDATION PLAN) h FIN. 1ST. FLR. 1 1-111-111-III-1 I, ,I 1 WALE.. SECTION S C A L E: 3/4" = 1'-0" vv, i METAL ROOF e12 00 WD. ROOF TRUSS AT 2' O.C. STUCCO ON 8" CBS WALL 5/8" GYP. BD. CLG. GALV. MTL. BOTT. TRACK SCREWED TO 2X4 P.T. WD WALL PL. W/ PDR. DRVN. PINS INTO CONC. SLAB. WALL SECTI GALV. MTL. TOP TRACK SCREW INTO BOTT OF RF. TRUSS CHORD. 1/2" GYP, BO. BOTH SIDES OF 3 5/8" (25 GA) GALV. MTL. STUDS ® 2' O.C. MAX. 4" CONC. FLR. SLAB W/ FLR. FINISHES AS PER SLR. PLANS ON !, S C A L E: 3/4" = 1'—O" FINISH . O BLK. WALL. FRONT E SCALE: TATION 1/4" = V-0" STUCCO ON CONT CAULK WOOD DOOR FRAME W/ ANCHORS TO WALL AS PER NOTES BELOW. APPROVED 2X4 P.T. WOOD NOW. BUCK CONT CAULK ALUM. FRMD. WDW. W/ ANCHORS TO WALL AS PER NOTES BELOW. APPROVED 2X4 P.T. WOOD WDW. BUCK 1/2" GYP. BD.--� 1/2" .GYP. BD., ON 1X3 P.T. WD. ON 1X3 P.T. WD. .FURRING STRIPS FURRING STRIPS CONC BLK ANCHORAGE DTL CONC BLK ANCHORAGE DTL DOOR DETAIL rB WDW DETAIL A S C A L E: 1 1/2" = 1'—O" 3 S C A L E: 1 1/2" 1'-0" 3 ALL ANCHORAGE TO BE WITHIN 6- FROM EACH CORNER AND AS MAXIMUM OR 16" BETWEEN CENTERS. SHIMS TO'. 'TAPCON' ANCHOR THRU WOOD 3/16" AT MASONRY. WALL: BE USED TO FILL THE VOIDS AT ALL ANCHORAGE POINTS. BUCK WITH MIN. 3/4" PENETRATION INTO CONCRETE. 2 AT WOOD FRMD. WALL: #10SMS SCREWS WITH MIN. 3/4" WINDOW/DOOR OPENING SEALANT ) PENETRATION OF THE WOOD FRAMING MEMBER. PROVIDE 'TREMCD VULKEM 116' WATERPROOFING SEALEANT AROUND OPENINGS BEFORE INSTALLATION OF WINDOWS AND EXTERIOR DOORS. LOUVER CLOSED INSIDE ATTIC W/ 5/8" PLYWD. TRUSS BRG EL. 9'-4" A.F.F. STUCCO FINISH ON - 8' CONC. BLK. WALL. TYP. FIN. FLR. EL. 0'-0" ROOF RIGHT SIDE ELEVATION S C A L E: 1/4" = 1'-0" METAL ROOF 12 5 F_ REAR ELEVATION S C A L E: 1/4" = 1'-0" ROOF 12 5 q W co Z3 co �13M VZ cD F M�� Z� ow ac Nff CL a, V �co ilk 0 (� (. 0- �WO �Z OOD n O a�/�. GO NMI cc Ov gSIONS: 07 OCT 2019 DEPT COMMEN 1, DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS HAVE PRECEDENCE OVER ALL TRUSS BRG SCALED DIMENSIONS '-r EL. 9'-4" A.F.F. Z CONTRACTOR TO VERIFY ALL DIMENSIONS & ADVISE ARCHITECT OF ANY DISCREPANCIES CONSTRUCTION SWYL NOT PROCEED UNTIL SAID DISCREPANCIES HAVE BEEN RESOLVED BY ARCHITECT. a tD MRIERDV S Dt SYSTEMS ARE TO BE FABRICATED UNTIL: A ALL DIMENSIONS HAVE BEEN VERIFIED BY THE CONTRACTOR B. SHOP DRAWINGS HAVE BEEN REVIEWED & ACCEPTED BY THE ARCHITECT. — STUCCO FINISH [IN 8' CONC, BLK: WALL. TYP.. FIN. FLR. EL. 0'-0" REVIM ED FOR CODE CCIl9IPI.ANCE ST. LUCIE�+CCmJNTY BOCC FILE COPY u z W W Q W � U x �a E d� �N 0 W �a H a DATE: 122 AOC>? *18 PROJECT NO: 17 - W117 SHEETA31 of 3