HomeMy WebLinkAboutPA FL9777-R11fwpicA a.;
Business & Professional Regulation t�.
...... ..
ram s
BCLS Nome ; LOg In User REgistratlon ' Hct TOPICS Submit Surcharge Stats & Facts Publlcations ' Canton Us DaS Ste Map Links Search
le% dbProduct Approval
[ "'USER: Public User
.... . . . P
2r ucC Auoroval Menu > _Prgtluct or Apoftation Search > goalicetlan, List a Applieatian Detail
FL # FL9777-R11
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
g req.keeler@owenscorning _com
Authorized Signature Greg Keeler
g reg. keeler@owenscorning_com
Technical Representative
Add ress/ PhorTe/ Ema i l
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Methoa Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quaiity Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden P.E.
o Validation Checklist - Hardcopy Received
Certificate of Independence FL9777 R11 CO! OCR)4002.8a2Q.17 >"BC Evaluatigrt,Renort W otherloc
Non-HVHZ,pd
Referenced Standard and Year (of Standard) Standard year
ASTM D 1970 2015
ASTM D 226 �009
ASTM G 155 2005
https://www.tloridabuNding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgtgkcMGbICW71%2fZr7gduilvKF-1MFg53ndV607883S6S6Kw%3d%3d Page t of 3
TAS 103
UL 1897
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option
Date Submitted
10/1i/2417
Date Validated
10/11/2017
Hate Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
Summary of Products
1995
2012
FL #
Model, Number or Name ;Description
9777.1
Weatherlock G
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL9777 m
Weatherlock Nori-HVHZ ❑df
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
EL9777 Uj—LE 0Q&j!j 42.8a ZD�.7 FBC Evalu�,i.j. n Repgrt
Weatherlock Non-HVH .pd
Created by Independent Third Party: Yes
9777.2 WeatherLeck G (High Tear)
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
FL 7 .. R11 II OCR14002,8a 20 L7 FBC Evaluation Re=
Weatherfoc.1i; Non-KyUZ.Qdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
s4727_ Rif AE QCR140Ua.0 20.17 FBC EvaluationRepo
WP.a�,�terl6Ci< NQ,rt_HVHZ. off
Created by Independent Third Party: Yes
9777.3 Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
LF 977?_RI1 11 R 4 .8 7 FBC Evaluation Repgr
Weatherlock HVHZ.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Thlyd Party: Yes
Evaluation Reports
FL9777 R11 AE QCR140p7, Sb 2017 FI3,C Evaluation Re=
WMtherioek HVHZ.ndf
Created by Independent Third Party: Yes
9777.4
Weatherlock MAT
Waterproofing UnderiaymentT
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
i Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other See evaluation report for limits of use.
FL9777 RJ1 [I OCR11002.8a 2017,FSC>=valual n Re of
W ath rl N -HVH _ f
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777R11_8 -0CR1400j.Sa 2017, FQC EvaluatjgrReoort
Weatherlock Non-HVHZx ff
Created by Independent Third Party: Yes
httPs://www,ficridabuT[ding.org/pr/pr_app-dtLaspx?pararn=wGEVXQwtDgtgkrMGblCW71%2fZr7gdugvKF1MFg53ndV601883S636Kw%3d13d Page 2 of 3
7.5 WeatherLock Metal
Weatherproofing Underlayment
its of Use
proved faruse in HVHZ: No
proved for use outside HVHZ: Yes
Resistant: N/A
rsign Pressure: NIA
Other: See evaluation report for limits of use.
Installation Instructions
iJ2777 R11 II R 4002. 2 17 F V lu i n
Weatherlo Non-Fi HZj))pact
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R:1 AE CCR1400Ma 2017„ABC EvaN.atio___ n Re=
Weatherlock Non-HVHZ pd
Created by Independent Third Party: Yes
9777.6
WeatherLock Metal
Weatherproofing Underlayment
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
L9777_R1_ 1 II OCR140QZ.8_ - 6 20,17 FBC EvLUgUon RewI
Weathedock HVHZ. df
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
EL9777_ 1-1 AE (1_CR14002.8b 2017„EX EVaiud,liuri Repo
W th r HVH
Created by Independent Third Party: Yes
9777.7
WeatherLock Specialty Tile & Metal
Weatherproofing Underlayment
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: f0/-142.5
Other: See evaluation report for limits of use.
Installation Instructions
EL1777 R11-_11 OCR14042.8a Z017 FBC Evaltiarinrt
Weatherlock NQn HVrjvdf
Verified By: Zachary P. priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
9777 R11 AE QC.R140QZqL2QjZ_E5C Ev € n R 2
M�2atherlggk NQn-HVHZpdf
Created by Independent Third Party: Yes
Sack H6xE
COnta[t Us :: 269181air Stone ROZd TallahasseCFL 373g9 Phone-. 850-487-1824
The State of Florida is an AA/EEO employer, C�pynght 2007-2013 State of Florida.:: PrfY4CV Statement :: A i i I em n FRe undi qtataMen
Under Florida iaw, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic
mall to this entityinstead, contact the office by phone or by traditional mail. If you have any questions, please contact 550.487.1395. 'Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are pubilc record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public- To determine if you are a licensee under Chapter
455, F-S., please click here .
Product Approval Accepts:
® A
�Pjwe-a
lecuritvAll TRIOS
hops://www.floridabuilding-org/pr/pr_app_dti-arpx?param=wGEVXQwtDgtgkcMGblcW71%2fZr7gdugvKE1MFg53ndV607889SS36Kw%3d3S3d Page 3 of 2
Certificate of Authorization No. 29824
CREEK17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES. LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 15-m EDITION (2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Corning Parkway
Toledo, OH 43657
(800) 438-7465
www.owenscoming.com
Manufacturing Location: Brentwood, NH
Houston, TX
Quality Assurance: UL LLC (QUA9825)
SCOPE
Category:
Roofing
Subcategory_
Underiayments
Code Sections:
1504.3.1, 1507.1 A
Properties:
Physical properties
REFERENCES
E tlty
Report Na_
Standard
Year
PRI Construction Materials Technologies (TST5878)
NEI-039-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-042-02-01REV2
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies {TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-093-02-02
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
CCF-213-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-237-02-01
UL 1897
2012
PRI Construction Materials Technoiagies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-272-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-296-02-02
ICC-ES AC 188'
2012
PRI Construction Materials Technologies (TST5878)
OCF-297-02-01.1
ICC-ES AC 48
ASTM d 1970
2012
2015
PRI Construction Materials Technologies {TST5878}
OCF-318-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OGF-320-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
OCF-321-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
QCF-322-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-355-02-01
UL 1897
2012
'Determined to be equivalent to ASTM ❑ 226-09, Type I
and II
0OR14002.8a FL9777-R11 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 51 G20-3. The manufacturer shaft notify CREEK
Technical Services, LLC of any product changes er quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
c nnniF-11- orl.d— e q h--;-
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LimiTS OF USE
OWENS CORNING ROOFING ANDASPHALT LLC
WeatherLvckQ Self -Sealing Ice ,& Water Barriers
WeatherLock®G
WeatherLock® G is an ASTM D 1970 self-adhesive underlayment constructed from SIBS
(Brentwood, NH)
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with norninal dimensions of 3-ft x 66.7-ft.
WeatherLock@ G is permitted to be used as prescribed in FBC Section 15C7.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days_
WeatherLock@ Mat
WeatherLock® Mat is an ASTM ❑ 1970 self-adhesive underlayment constructed from
(Brentwood, NH or
Houston, T)O
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock@ Metal
WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ Metal is permitted to be used as prescribed In FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock@
WeatherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, 7X)
WeatherLock@ Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BONDTM Root Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shalt not be stacked greater 10 tiles per stack.
WeatherLock@ G (High WeatherLock@ G (High Tear) is a self -adhered, underlayment used as an alternative to
Tear) ASTM D 226, Type I or Type Il roofing felt and ASTM D 1970 self -adhering polymer
(Houston, TX) modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-ft
WeatherLock® G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.8a FL9777-R11 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 51G20-3. The manufacturer shall notify CREEK
`technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
h;., CREEK
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
Min. Roof Slope: 2.12 in accordance with the FBC
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
Application: All underlayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to unde'dayment
application. Prior to beginning installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the cave, and with minimum 3" side
laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if
applying WeatherLockg Specialty Tile & Metal, end laps shall be primed with ASTM ❑
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads Flush to the top surface of the
underlayment). Additionafly, WeatherLockD Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underla ment system No.1—V1leatherLock S ecia! Tile & Metal Qnl
Roof Deck: Min. 15132-inch CDx plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-114-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" c.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a FL9777-RI t Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
nnerifinnll,� arlr�ronn4� },o roin
jCREED
TECHNICAL SERVICES, LILC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
Weatherl-ooUD Self -Sealing Ice & Water Barriers
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacture's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) resign wind load pressures shall be determined for components and cladding in accordance with FBC
1609,
9) The roof deck shall be designed by others it accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) Alf products listed In this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P_E. have demonstrated compliance with the Florida Building
Code 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
till I 111)11 jj1,
4 No 74021
� 3 STATE OF 'Cr
�
p
ir+fs&'Q N Ai ►E��,'
CERTIFICATION OF INDEPENDENCE
2017.10.11
09:0629
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E, does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
product.
END OF REPORT
❑CR14002.$a FL9777-R11 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not