HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLRIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 25 Block 46-7 IndianRiverEsiates 1755 AGR
Builder Name: ADAMS HOMES
Street: 5003 Sunset Boulevard
'
Permit Office:
JAN 2 12020
City, State, Zip: Fort Pierce , FL-, 34982
Permit Number:
Owner:
Design Location: FL, ST_LUCIE_CO_INTL
Jurisdiction: 661000
County: St. Lucie (Florida Climat
ST. Lucie County, Permitting
1. New construction or existing New (From Plans)
9. Wall Types;(1512.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Exterior
R=4.1 1348.00 ftz
3. Diu ber of units, if multiple family 1
b. Frame - Wood, Adjacent
R=.13.0 164.00 ftz
4. Nurriber'of Bedrooms 4
C. N/A
d. N/A
R= ftz
5. Is this a worst case? No
10. Ceiling Types (1828.0 sgft.)
R= ftz
Insulation Area
a. Under Attic (Vented)
R=30.0 1760.00 ftz
6. Conditioned floor area above grade (ftz) 1760
b. Knee Wall (Vented)
R=19.0 68.00 ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
7. Windows(212.0 sqft.) Description Area
11. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ftz'
6 352
a. U-Factor: Dbl, U=0.33 129.50 ftz
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 46.38 •ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:15.50
c. U-Factor: Dbl, U=0.33 18.33 ftz
SHGC: 8HGC=0.31
13. Heating systems
kbtu/hr Efficiency
d. U-Factor: other (see details) 17.78 ftz
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC: other (see details) .
Area Weighted Average Overhang Depth: 1.923 ft.
Area Weighted Average SHGC: 0.272
14. Hot water systems
8. Floor Types (1760.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1760.00 ftz
b. Conservation features
EF: 0.940
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Total Proposed Modified Loads: 56.52
Glass/Floor Area: 0.120 ;
PASS4
Total Baseline Loads: 59.7
I hereby certify that the plans and specifications covered by
Review of the plans and^?k1>E',�
this calculation are in complianc i e Florida E
specifications covered by this
= 4.
Cod^..
calculation indicates compliance
PARED
with the Florida Energy Code.
F. rfill, � „ 0
BY:
Before construction is completed
DATE: 12-3-19 Winn Kennnany
this building will be inspected for
compliance with Section 553.908
'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
,5
with the Florida Energy Code.
q� •;L
'DWE
OWNER/AGENA
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by. the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance. requires an Air Barrier and, Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50i(11402.4.1.2).
FILE
12/3/2019 5:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
S
FORM R405-2017 INPUT SUMMARY r_I4F['.KI IST RFPnRT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Ekisting:
Comment:
Lot 25 Block 46-7 IndianRiver Bedrooms: 4
User Conditioned Area: 1760
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot # 25
Block/Subdivision: IndianRiverEst.
PlatBook:
Street: 5003 Sunset Boulevard
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34982
CLIMATE
/ ,
�/ Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1760 15136
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1760 15136 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 167.5 ft 0
1760 ftz ---- 0.33 0 0.67
ROOF
/
#
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1968 ftz 440 ftz Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
V #
•
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1760 ftz N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Knee Wall (Vented)
Under Attic (Vented)
Main 19 Batt
Main 30 Blown
68 ftz 0.11 Wood
1760 ftz 0.11 Wood
12/3/2019 5:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHFCKusT RFPnRT
WALLS
Ornt
Adjacent
TnSpace CaV.vity Width
Height
Sheathing Framing Solar Below
1
NW
Exterior Concrete Block - Int Insul Main
4.1 43 0 8
0 344.0 ft2
0 0 0.6
0
2
NE
Exterior Concrete Block - Int Insul Main
4.1 34 0 8
0 272.0 ft2
0 0 0.6
0
3
SE
Exterior Concrete Block - Int Insul Main
4.1 37 0 8
0 296.0 ft2
0 0 0.6
0
4
SW
Exterior Concrete Block - Int Insul Main
4.1 54 6 8
0 436.0 ft2
0 0 0.6
0
5
-
Garage Frame - Wood Main
13 20 6 8
0 164.0 ft2
0 0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width Height
Area
Ft
In Ft In
1
NE Insulated Main
None
.25 3
6 8
20 ft2
2
- Wood Main
None
.25 2
8 6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation Int Shade
Screening
1
NW 1 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft2 1 ft 4 in
0 ft 10 in None
Exterior 5
2
NE 2 Vinyl Low-E Double Yes
0.33 0.31 N
5.0 ft2 9 ft 0 in
0 ft 5 in None
None
3
NE 2 Vinyl Low-E Double Yes
0.33 0.21 N
46.4 ft2 1 ft 0 in
0 ft 10 in None
Exterior 5
4
NE 2 Vinyl Low-E Double Yes
0.33 0.31 N
13.3 ft2 9 ft 0 in
2 ft 6 in None
None
5
SW 4 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft2 1 ft 4 in
0 ft 10 in None
Exterior 5
6
SW 4 Vinyl Low-E Double Yes
0.33 0.23 N
113.3 ft2 1 ft 4 in
0 ft 10 in None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
427 ft2 427 ft2
64 ft
8 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000383
1765.9 96.94 182.32 .1364
7
•
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
HSPF:8.5
34.6 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/ Split
SEER: 15.5 35 kBtu/hr 1167 cfm 0.75 1
sys#1
12/3/2019 5:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHFCKI 1ST RFPnRT
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 352 ft2
Main
88 ft2 Default Leakage
Main
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan [ Feb
HeatinJan [X Feb
(� Mar
[ Mar
r Apr
(j APr f
Jul
May JunJul
Ma rj Jun rl
AuSep
rl Aug
Se
rl
Wct
ct
Nov
Nov
H
HDec
Dec
Ventin Jan [ Feb
• [X] Mar
[[[XXX]]] A r [
Ma Jun Jul
Aug
Se
ct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Main
1213/2019 5:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) .DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* ='95
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From. Plans) 12, Ducts, location & insulation level
a), Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family 6) Return ducts R 6.0
c) AHU location : Main
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0
a). Split system SEER 15.5
5. Is this a worst case? (yes/no) 5. No b); Single package SEER,
c)'Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.):. 6. 1760 d), Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. .0.348
b) Solar Heat Gain Coefficient (SHGC) 7b: 0:272 14. Heating system: Capacity 34.6
c) Area 7c. 212.0 a),Split system heat pump ' HSPF 8.5
b): Single package heat pump HSPF.
8: Skylights c)! Electric resistance COP
a) 0-factor: (weighted average) 8a: NA 4Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC) 8b. NA e){Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value) 9a. 0.0
b) Wood, raised (R-value) 9b. 15. Water heating system.
c) Concrete, raised (R-value) 9c. a)! Electric resistance EF 0.94
b);Gas fired, natural gas EF
10. Wall type and insulation: c)lGas fired, LPG EF
A. Exterior: d)!Solar system with tank . EF
1. Wood frame (Insulation R-value) 10A1. e)j Dedicated heat pump with tank EF
2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B. Adjacent: g)!Other
1. Wood frame (Insulation R-value) 10131. 13.0
2. Masonry (Insulation R-value) 10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a)iCeiling fans
a) Under attic 11 a. 30.0 b);Cross ventilation No
b) Single assembly 11 b. c)!Whole house fan No
c) Knee walls/skylight walls 11 c. 19.0 d)!Multizone cooling credit
d) Radiant barrier installed 11 d. No e)!Multizone heating credit
f) programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.dl
i
Builder SignaDate:-!r %
Address of New Home: 5003 Sunset Boulevard City/FIL Zip: Fort Pierce, FL 34982
12/3/2019 5:36:30 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 F6C 6th Edition (2017) Compliant Software Page 1 of 1