Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLRIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 25 Block 46-7 IndianRiverEsiates 1755 AGR Builder Name: ADAMS HOMES Street: 5003 Sunset Boulevard ' Permit Office: JAN 2 12020 City, State, Zip: Fort Pierce , FL-, 34982 Permit Number: Owner: Design Location: FL, ST_LUCIE_CO_INTL Jurisdiction: 661000 County: St. Lucie (Florida Climat ST. Lucie County, Permitting 1. New construction or existing New (From Plans) 9. Wall Types;(1512.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int Insul, Exterior R=4.1 1348.00 ftz 3. Diu ber of units, if multiple family 1 b. Frame - Wood, Adjacent R=.13.0 164.00 ftz 4. Nurriber'of Bedrooms 4 C. N/A d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (1828.0 sgft.) R= ftz Insulation Area a. Under Attic (Vented) R=30.0 1760.00 ftz 6. Conditioned floor area above grade (ftz) 1760 b. Knee Wall (Vented) R=19.0 68.00 ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 7. Windows(212.0 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Main, AH: Main R ftz' 6 352 a. U-Factor: Dbl, U=0.33 129.50 ftz SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 46.38 •ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl, U=0.33 18.33 ftz SHGC: 8HGC=0.31 13. Heating systems kbtu/hr Efficiency d. U-Factor: other (see details) 17.78 ftz a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) . Area Weighted Average Overhang Depth: 1.923 ft. Area Weighted Average SHGC: 0.272 14. Hot water systems 8. Floor Types (1760.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1760.00 ftz b. Conservation features EF: 0.940 b. N/A R= ftz None c. N/A R= ftz 15. Credits Pstat Total Proposed Modified Loads: 56.52 Glass/Floor Area: 0.120 ; PASS4 Total Baseline Loads: 59.7 I hereby certify that the plans and specifications covered by Review of the plans and^?k1>E',� this calculation are in complianc i e Florida E specifications covered by this = 4. Cod^.. calculation indicates compliance PARED with the Florida Energy Code. F. rfill, � „ 0 BY: Before construction is completed DATE: 12-3-19 Winn Kennnany this building will be inspected for compliance with Section 553.908 ' I hereby certify that this building, as designed, is in compliance Florida Statutes. ,5 with the Florida Energy Code. q� •;L 'DWE OWNER/AGENA BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by. the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance. requires an Air Barrier and, Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50i(11402.4.1.2). FILE 12/3/2019 5:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 S FORM R405-2017 INPUT SUMMARY r_I4F['.KI IST RFPnRT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Ekisting: Comment: Lot 25 Block 46-7 IndianRiver Bedrooms: 4 User Conditioned Area: 1760 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 25 Block/Subdivision: IndianRiverEst. PlatBook: Street: 5003 Sunset Boulevard County: St. Lucie City, State, Zip: Fort Pierce , FL, 34982 CLIMATE / , �/ Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1760 15136 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1760 15136 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 167.5 ft 0 1760 ftz ---- 0.33 0 0.67 ROOF / # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1968 ftz 440 ftz Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # • Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1760 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Knee Wall (Vented) Under Attic (Vented) Main 19 Batt Main 30 Blown 68 ftz 0.11 Wood 1760 ftz 0.11 Wood 12/3/2019 5:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHFCKusT RFPnRT WALLS Ornt Adjacent TnSpace CaV.vity Width Height Sheathing Framing Solar Below 1 NW Exterior Concrete Block - Int Insul Main 4.1 43 0 8 0 344.0 ft2 0 0 0.6 0 2 NE Exterior Concrete Block - Int Insul Main 4.1 34 0 8 0 272.0 ft2 0 0 0.6 0 3 SE Exterior Concrete Block - Int Insul Main 4.1 37 0 8 0 296.0 ft2 0 0 0.6 0 4 SW Exterior Concrete Block - Int Insul Main 4.1 54 6 8 0 436.0 ft2 0 0 0.6 0 5 - Garage Frame - Wood Main 13 20 6 8 0 164.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 2 NE 2 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 9 ft 0 in 0 ft 5 in None None 3 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 46.4 ft2 1 ft 0 in 0 ft 10 in None Exterior 5 4 NE 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 ft 0 in 2 ft 6 in None None 5 SW 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 6 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 113.3 ft2 1 ft 4 in 0 ft 10 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000383 1765.9 96.94 182.32 .1364 7 • HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1167 cfm 0.75 1 sys#1 12/3/2019 5:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHFCKI 1ST RFPnRT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 352 ft2 Main 88 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan [ Feb HeatinJan [X Feb (� Mar [ Mar r Apr (j APr f Jul May JunJul Ma rj Jun rl AuSep rl Aug Se rl Wct ct Nov Nov H HDec Dec Ventin Jan [ Feb • [X] Mar [[[XXX]]] A r [ Ma Jun Jul Aug Se ct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Main 1213/2019 5:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) .DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* ='95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From. Plans) 12, Ducts, location & insulation level a), Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family 6) Return ducts R 6.0 c) AHU location : Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a). Split system SEER 15.5 5. Is this a worst case? (yes/no) 5. No b); Single package SEER, c)'Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.):. 6. 1760 d), Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. .0.348 b) Solar Heat Gain Coefficient (SHGC) 7b: 0:272 14. Heating system: Capacity 34.6 c) Area 7c. 212.0 a),Split system heat pump ' HSPF 8.5 b): Single package heat pump HSPF. 8: Skylights c)! Electric resistance COP a) 0-factor: (weighted average) 8a: NA 4Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e){Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system. c) Concrete, raised (R-value) 9c. a)! Electric resistance EF 0.94 b);Gas fired, natural gas EF 10. Wall type and insulation: c)lGas fired, LPG EF A. Exterior: d)!Solar system with tank . EF 1. Wood frame (Insulation R-value) 10A1. e)j Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g)!Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a)iCeiling fans a) Under attic 11 a. 30.0 b);Cross ventilation No b) Single assembly 11 b. c)!Whole house fan No c) Knee walls/skylight walls 11 c. 19.0 d)!Multizone cooling credit d) Radiant barrier installed 11 d. No e)!Multizone heating credit f) programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features.dl i Builder SignaDate:-!r % Address of New Home: 5003 Sunset Boulevard City/FIL Zip: Fort Pierce, FL 34982 12/3/2019 5:36:30 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 F6C 6th Edition (2017) Compliant Software Page 1 of 1