HomeMy WebLinkAboutEvaluation Report; Polyglass Roof Underlaymentct4
ENGINEER EVALUATE
'IN RFPr)F
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
TEST CONSULT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R26
1111 West Newport Center Drive FL5259-R30
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954) 233-1230 Revision 26: 07/06/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 16.
Prepared by: a"""
Robert J.M. Nieminen, P.E.
F
'rd n.�,�n�� The facsimile seal a thori,,d b
Florida Registration No.59166,FloridaDCAANE1983 appearing v Robert Nieminen, P.E. on
07/06/2020. This dooesesnot serve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOletc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO Jetc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC, LLC
*NEMOI etc.
#25
Maximum Design Pressure = -67.5 qsf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment)
Fasteners:
12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#26
Maximum Design Pressure=-67.5 qsf:
Deck:
APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180` into the holes of the plate, parallel to
the width direction of the sheet.
Spacing:
12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer:
(Optional) PG100 or ASTM D41 primer applied to stress plates.
Base Ply:
(Optional) Polystick MTS Plus, self -adhered.
Underlayment:
Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#27
Maximum Design Pressure = -67.5 qsf:
Deck:
APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase (sand top surface)
Fasteners:
TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width direction of the sheet.
Spacing:
12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment:
Elastoflex 56 G, applied in full mopping of hot asphalt.
#28
Maximum Design Pressure = -67.5 psf:
Deck:
APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase or Polyglass Base
Fasteners:
TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#29 Maximum Design Pressure = -75 qsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#30 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#31 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: CMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P12060.02.09-1126
Certificate of Authorization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 10 of 16
*NEMOI etc.
#32 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#33 Maximum Design Pressure=-90 qsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#34 Maximum Design Pressure=-90.0 qsf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#35 Maximum Design Pressure=-90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#36 Maximum Design Pressure=-90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#37 Maximum Design Pressure=-97.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1126
Certificate of Authorization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 11 of 16
*NEMOI etc.
#38
Maximum Design Pressure = -97.5 psf:
Deck:
APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates.
Base Ply:
(Optional) Polystick NITS Plus, self -adhered.
Underlayment:
Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FIR), Polyflex SA P, Polyflex SA P FIR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#39
Maximum Design Pressure=-97.5 psf:
Deck:
APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase (sand top surface)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt.
#40
Maximum Design Pressure = -97.5 psf:
Deck:
APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase or Polyglass Base
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment:
Polyflex G, torch -applied.
#41
Maximum Design Pressure=-105 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment:
Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#42
Maximum Design Pressure = -105.0 psf:
Deck:
APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates.
Base Ply:
(Optional) Polystick MTS Plus, self -adhered.
Underlayment:
Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FIR), Polyflex SA P, Polyflex SA P FIR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#43
Maximum Design Pressure = -105.0 psf:
Deck:
APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase (sand top surface)
Fasteners:
TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180` into the holes of the plate, parallel to
the width -direction of the sheet
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, U.C.
Evaluation Report P12060.02.09-1126
Certificate of Authorization#32455
6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 12 of 16
*NEMOI etc.
#44 Maximum Design Pressure = -105.0 qsf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#45 Maximum Design Pressure = -112.5 qsf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS Plus, self -adhered
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#46 Maximum Design Pressure = -120 qsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#47 Maximum Design Pressure = -120 qsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#48 Maximum Design Pressure = -127.5 qsf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#49 Maximum Design Pressure = -127.5 qsf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
#50 Maximum Design Pressure = -127.5 Psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R26
Certificate of Authorization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1130
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 13 of 16
*NEMOI etc.
5.6.1.1 All other direct -deck, adhered Polyglass underlayment systems beneath adhesive -set tile systems carry a Maximum Design
Pressure of -45 psf.
5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that
required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure
determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a
qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk' carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Maximum Exposure (days)
HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick NITS Plus, Polystick TU Max, Polystick TU P,
180
Polystick TU Plus or Polystick XFR
Polystick IR-Xe or Polystick MU-X
90
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
30
180
(for adhesive -set tile)
Elastoflex 56 G, Elastoflex 56 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet
UNLIMITED
(FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR
(for mechanically fastened roof
prepared roof covers)
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing
felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in
Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These
slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex 56 G or 56 G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
HydraGuard Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick NITS Plus
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohibited without battens
NEMO ETC, U.C. Evaluation Report P12060.02.09-R26
certificate of Authorization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 14 of 16
NNEMOI etc.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed and Polyglass published requirements.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -
Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G
or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set
forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply
System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.1 herein, coupled with FRSA/TRI April
2012 (04-12) Installation Manual.
6.4
HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P,
Polyflex SA P FR, Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus or
Polystick XFR:
6.4.1 General:
All seal -lap seams (selvage laps) must be firmly rolled with a in
accordance with Polyglass requirements to ensure full contact
and adhesion. For HydraGuard Dual Pro and HydraGuard Tile
Pro, align the edge of the top sheet to the end of the glue
pattern (the sheet will overlap the fabric).
View of Ovelap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
6.4.2 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the
type of prepared roof covering to be installed and Polyglass published requirements.
6.4.3 Tile Applications (excludes HydraGuard Dual Pro. Polystick IR-Xe and Polystick MU-X):
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI April 2012 (04-12) and
Polyglass published requirements.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet
fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.1 herein.
6.4.4 Multi -Ply Underlavment Systems:
Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU-X, Polystick
TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof
systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply
underlayment system is desired.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1126
Certificate of Authorization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 15 of 16
NNEMO I etc.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply System'
from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet'
in the "Two Ply System' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply
System' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap
Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates noted in Table
2. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side
and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond
the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-
12) beneath mechanically fastened or adhered tile roof systems (Refer to Table 2 for base sheet options).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened tile roof systems (Refer to Table 2 for base sheet options).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and
end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2
herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof
slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile
sliding and/or damage to the underlayment during the loading process.
7. BUILDING PERMIT REQUIREMENTS:
As required bythe Building Official or Authority Having Jurisdiction in orderto properly evaluate the installation ofthis product.
$. MANUFACTURING PLANTS:
Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements. Refer to
Section 4 herein for product & production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
END OF EVALUATION REPORT -
NEMO ETC, U.C. Evaluation Report P12060.02.09-R26
Certificate of Authorization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 16 of 16
ROOFING
*NEMOI etc.
1. SCOPE:
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement: Roof Underlayments, as produced by
Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 6t6
Edition (2017) Florida Building Code through testing in accordance
with the fallowing Standards.
Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
ILL 1897
2012
1507.2.3 / 1507.1.1
Material standard
ASTM D226
2009
1507.2.4/ 1507.1.1, 1507.2.9.2
Material standard
ASTM D1970
2015
1507.3.3
Material standard
FRSA/TRI April 2012
2012
1507.11.2
Material standard
ASTM D6163
2008
1507.11.2
Material standard
ASTM D6164
2011
1507.11.2
Material standard
ASTM D6222
2011
1507.11.2
Material standard
ASTM D6509
2009
TAS 110
Accelerated Weathering
ASTM D4798
2011
LailY
Examination
Reference
Date
E112p,
Examination
Reference
Date
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
ASTM D1970
PLYG-SC30130.06.16-1
06/27/2016
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Tensile adhesion
PLYG-SC30130.06.16-2
06/27/2016
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
TAS103
PLYG-SC30130.06.16-3
06/27/2016
ERD (TST 6049)
ASTM D1970
P5110.04.07-1
04/11/2007
ERD (TST 6049)
ASTM D1970/D4798
PLYG-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Wind Uplift
PLYG-SC32025.10.16
10/12/2016
ERD (TST 6049)
Wind Uplift
P30540.11.09-113
11/30/2009
ERD (TST 6049)
TAS103
PLYG-SC33040.12.16
12/27/2016
ERD (TST 6049)
Tensile Adhesion
P11030.11.09-1
11/30/2009
ERD (TST 6049)
30/90 physicals
PLYG-SC31900.03.17
03/10/2017
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11/30/2009
ERD (TST 6049)
TAS103
PLYG-SC32115.08.17
08/08/2017
ERD (TST 6049)
ASTM D4977
P13030.11.09-3
11/30/2009
ERD (TST 6049)
TAS103
PLYG-SC33035.08.17
10/31/2017
ERD (TST 6049)
ASTM D1970
P33360.06.10
06/25/2010
FM (TST 1867)
Wind Uplift
3004091
01/12/2000
ERD (TST 6049)
TAS103
P33370.03.11
03/02/2011
ICC-ES(EVL 2396)
IBCCompliance
ESR-1697
04/01/2019
ERD (TST 6049)
Tensile Adhesion
P33370.04.11
04/26/2011
M-D (CER 1592)
HVHZ Compliance
NOA 17-0614.22
07/06/2017
ERD (TST 6049)
ASTM D1970
P37300.10.11
10/19/2011
MTI (TST 2508)
ASTM D4798
JX20H7A
04/01/2008
ERD (TST 6049)
TAS103
P40390.08.12-1
08/06/2012
NEMO (TST 6049)
ASTM D1970
4-PLYG-18-004.03.18
03/29/2018
ERD (TST 6049)
Tensile Adhesion
P40390.08.12-2
08/07/2012
NEMO(TST 6049)
Wind Uplift
4L-PLYG-18-003.01.19
01/11/2019
ERD (TST 6049)
Tensile Adhesion
C41420.09.12-3
09/11/2012
NEMO (TST 6049)
ASTM D6163
4S-PLYG-18-002.01.19-A
01/24/2019
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
NEMO(TST 6049)
ASTM D6222
4S-PLYG-18-002.05.19-C
05/20/2019
ERD (TST 6049)
ASTM D1970
P45370.04.13
04/26/2013
NEMO (TST 6049)
ASTM D1970
4j-PLYG-I9-SSUDL-00.A
09/10/2019
ERD (TST 6049)
Wind Uplift
P3738.02.07-R2
04/29/2013
NEMO(TST 6049)
TAS103
4S-PLYG-18-004.10.19-G
10/08/2019
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1
04/30/2013
NEMO (TST 6049)
TA5103
45-PLYG-18-004.30.19-1
10/08/2019
ERD (TST 6049)
ASTM D6164
P37590.03.13-3A
05/06/2013
NEMO (TST 6049)
TA5103
45-PLYG-18-004.30.19-L
10/09/2019
ERD (TST 6049)
ASTM D6509
P37590.03.13-1-R1
06/26/2013
NEMO (TST 6049)
TA5103
4j-PLYG-I9-SSUDL-01.A
10/10/2019
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
NEMO (TST 6049)
TA5103
4j-PLYG-I9-SSUDL-02.A
01/02/2020
ERD (TST 6049)
ASTM D4601
P45940.09.13
09/04/2013
NEMO (TST 6049)
ASTM D1970
45-PLYG-18-004.01.20.H
01/14/2020
ERD (TST 6049)
Wind Uplift
P31751.05.03-R3
11/26/2013
NEMO (TST 6049)
ASTM D1970
45-PLYG-18-004.01.20.K
01/14/2020
ERD (TST 6049)
Wind Uplift
P31781.11.03-R3
11/26/2013
NEMO (TST 6049)
TA5103
4j-PLYG-20-SSUDL-01
07/06/2020
ERD (TST 6049)
30/90 physicals
P45270.05.14
05/12/2014
PRI(TST 5878)
Tensile Adhesion
PRIO1111
04/08/2002
ERD (TST 6049)
Tensile adhesion
6020.09.14-5
09/08/2014
PRI(TST 5878)
TA5103
PUSA-018-02-01
07/14/2003
ERD (TST 6049)
Tensile adhesion
6020,09.14-6
09/08/2014
PRI(TST 5878)
TA5103
PUSA-035-02-01
09/29/2006
ERD (TST 6049)
Tensile adhesion
P46520.30.14
10/03/2014
PRI(TST 5878)
TA5103
PUSA-055-02-02
12/10/2007
ERD (TST 6049)
ASTM D1970/D4798
P43290.10.14
10/17/2014
PRI (TST 5878)
ASTM D6222
PUSA-061-02-02
01/28/2008
NEMO ETC, I.I.C.
Evaluation Report P12060.02.09-R26
Certificate of Authorization#32455
6- EDITION (2017) FBC
NON-HVHZ EVALUATION
F1.5259-1130
Polyglass Roof Underlayments;
(954) 233-1230
Revision
26: 07/06/2020
Page 2 of 16
Entity Examination
Reference
Date
EnU
Examination
ERD (TST 6049) TAS 103
PLVG-SC7550.03.15
03/24/2015
PRI (TST 5878)
ASTM D6164
ERD(TST 6049) Tensile adhesion
P40390.04.15
04/03/2015
Polyglass USA
P/L Affidavit
ERD(TST 6049) TAS103
P44360.10.14-R1
05/18/2015
Polyglass USA
Materials Affidavit
ERE) (TST 6049) Wind Uplift
PLVG-SC8905.05.16-1
05/17/2016
UL(QUA9625)
Quality Control
4. PRODUCT DESCRIPTION:
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
NNEM o I etc.
Reference Date
PUSA-088-02-01 07/29/2009
Mule -Hide Cross Ltg 03/01/2008
Polystick Compound 08/18/2011
Service Confirmation 09/13/2018
Product
Specification
Plant(s)
Description
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex S6 G
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRIApril 2012
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRIApril 2012
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRIApril 2012
HydraGuard Dual Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
HydraGuard Tile Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
TAS 103
waterproofing membrane, fiberglass reinforced, with a
FRSA/TRI April 2012
polyester fabric surface
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
(FR)
FRSA/TRI April 2012
Polyflex G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI April 2012
use as an alternate to Heat Applied "Cap Sheet' in the
"Two Ply System" from FRSA/TRI April 2012 (04-12)
beneath mechanically fastened or adhered tile roof
systems
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI April 2012
use as an alternate to Heat Applied "Cap Sheet' in the
"Two Ply System" from FRSA/TRI April 2012 (04-12)
beneath mechanically fastened tile roof systems
Polyflex SA P
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRIApril 2012
Polyflex SA P FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRIApril 2012
Polyglass Base
ASTM D6509
FL
Fiberglass -reinforced, APP modified bitumen base sheet
Polyglass G2 Base Sheet
ASTM D4601
AL
Fiberglass -reinforced, asphaltic base sheet
Polystick IR-Xe
ASTM D1970
FL, PA
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
Polystick MTS Plus
ASTM D1970
FL, NV,
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
PA, TX
membrane, glass fiber reinforced, surfaced with
FRSA/TRI April 2012
polyolefinic film surface
NEMO ETC, LLC. Evaluation Report P12060.02.09-R26
Certificate of Authorization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 3 of 16
4.17
4.18
4.19
4.20
4.21
NNEMOI etc.
PRODUCT DESCRIPTION:
Product
Specification
Plant(s)
Description
Polystick MU-X
ASTM D1970
FL, NV, PA
Nominal 54-mil thick dual -layer rubberized asphalt
(See Section 5.8)
waterproofing membrane, fiberglass reinforced, with a
polypropylene film surface
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
membrane with a 190 g/m2 polyester fabric surface
FRSA/TRI April 2012
Polystick TU P
TAS 103
TX
Nominal 130-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012
membrane, glass-fiber/polyester reinforced, with a
granular surface
Polystick TU Plus
ASTM D1970
FL, PA
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, with a polyester fabric
FRSA/TRI April 2012
surface
Polystick XFR
ASTM D1970
NV
Nominal80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, surfaced with a
FRSA/TRI April 2012
textured film surface
S. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for
any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties).
5.3 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Asphalt
Clay and Concrete Tile
/1507.3J
Metal
Slate
Wood
Underlayment
Shingles
Shingles
Mechanical
Adhesive -Set
Panels
Shingles
Shingles
Shakes
llsd7.IJ
115077J
Attach
lss07.4J
/isozsl
llsozeJ
llso7si
Yes
Yes
Elastobase
Yes
(Base Sheet in 2-ply
(Base Sheet in 2-ply
Yes
Yes
Yes
No
No
system)
system)
Yes
Yes
ElastobaseP
Yes
(Base sheet in 2-ply
(Base Sheet in 2-p1y
Yes
Yes
Yes
No
No
system)
system)
Yes
Yes
Polyglass Base
No
(Base Sheet in 2-ply
(Base Sheet in 2-p1y
No
No
No
No
No
system)
system)
Yes
Yes
Polyglass G2 Base
No
(Base Sheet in 2-ply
(Base Sheet in 2-ply
No
No
No
No
No
system)
system)
Yes
Elastoflex56G
Yes
Yes
(See 5.5.1)
No
No
Yes
No
No
Elastoflex S6 G FR
Yes
Yes
No
No
No
Yes
No
No
HydraGuard Dual Pro
Yes
No
No
Yes
Yes
Yes
Yes
Yes
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R26
Certificate of Authorization#32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 4 of 16
NNEMOI etc.
TABLE 1: ROOF COVER OPTIONS
Asphalt
Clay and Concrete Tile
(I5o7.3)
Metal
Slate
Wood
Underlayment
Shingles
Shingles
Mechaanical
Adhesive -Set
Panels
Shingles
Shingles
S hakes
(1507I)
(15077)
gtt ch
(1507.4)
(1507.5)
(1507.8)
(1507.9)
HydraGuard Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Yes
Yes
Mule -Hide SA-APP Cap Sheet
Yes
Yes
(See5yes.5.1)
No
No
Yes
No
No
Mule -Hide SA-APP Cap Sheet (FR)
Yes
Yes
(See 55.1)
No
No
Yes
No
No
PolyflexG
Yes
Yes
yes
No
No
Yes
No
No
(See 5.5.1)
PolyflexG FR
Yes
Yes
No
No
No
Yes
No
No
Polyflex SA P
Yes
Yes
Yes
No
No
Yes
No
No
(See 55.1)
Polyflex SA P FR
Yes
Yes
No
No
Yes
No
No
(See 55.1)
Polystick IR-Xe
Yes
No
No
No
No
Yes
Yes
Yes
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Polystick TU Max
No
Yes
yes
Yes
Yes
No
Yes
Yes
(See 5.5.1)
Polystick TUP
No
Yes
yes
No
No
No
Yes
Yes
(See 5.5.1)
Polystick TU Plus
Yes
Yes
yes
Yes
Yes
Yes
Yes
Yes
(See 5.5.1)
Polystick XFR
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
5.5.1 "Adhesive -set Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS'
Florida Product
Adhesive
Approval
Underlayments
DAP Foam "Touch'n Seal StormBond
FL14506
Polystick TU Max or Polystick TU Plus
Roof Tile Adhesive"
Dupont "TILE BONDT" Roof Tile
HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or
Adhesive"
FL22525
Polystick TU Plus
ICP Adhesives and Sealants "Polyset®
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule-
AH-160"
FL6332
Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus
ICP Adhesives and Sealants "Polyset®
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule-
FL6276
Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR,
RTA-1"
Polystick TU Max, Polystick TU P or Polystick TU Plus
' Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R26
certificate of Authorization#32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1130
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 5 of 16
*NEMOI etc.
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads for project)
Application
Underlayment
Type
Primer
Material(s)
Deck /
(Optional) ASTM D41
Plywood, OSB, Southern Yellow Pine or Huber
HydraGuard Dual Pro,
Engineered Woods "ZIP System' Panels
HydraGuard Tile Pro,
sheathing
ASTM D41
structural concrete
Polystick (all variations),
Mule -Hide SA-APP Cap
self-
(Optional) ASTM D41
ASTM C1289 Type II Class 1 polyisocyanurate, ASTM
Sheet, Mule -Hide SA-APP
adhering
Insulation
or WB-3000
C1289 Type Vpolyisocyanurate-composite, DensDeck
Cap Sheet (FR), Polyflex
Prime or SECUROCK Gypsum -Fiber Roof Board
Base
N/A
ASTM D226 felt, Elastobase, Elastobase P or Mule -Hide
SA P or Polyflex SA P FR
Sheet
Nail Base
Deck
ASTM D41
structural concrete
Elastoflex S6 G or
hot asphalt
Insulation
(Optional) ASTM D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Base
N/A
ASTM D226 felt, Elastobase, Elastobase P, Mule -Hide Nail
Elastoflex S6 G FR
Sheet
Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete
Polyflex G or Polyflex G FR
torch-
Insulation
(Optional) ASTM D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Base
N/A
Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass
applied
Sheet
G2 Base or Polyglass Base
5.6.1 Wind Resistance for Underlayment Systems in Adhesive -set Tile Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April
2012 (04-12) and are used in adhesive -set or mortar -set tile applications. Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC
1609 for determination of design wind loads.
#1 Maximum Design Pressure=-52.5 Ds :
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all OSB joints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#2 Maximum Design Pressure=-90 Dsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Design Pressure=-97.5 Dsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y" ring shank nails
through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
NEMO ETC, LLC. Evaluation Report P12060.02.09-R26
Certificate of Authorization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 6 of 16
*NEMOI etc.
#4 Maximum Design Pressure = -105 qsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or PolystickTU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y" ring shank nails
through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#6 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
PolystickTU Max, Polystick TU P or PolystickTU Plus, self -adhered.
#7 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#8 Maximum Design Pressure=-30.0 psf*:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#9 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#10 Maximum Design Pressure = -37.5 qsf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, U.C. Evaluation Report P12060.02.09-1126
Certificate of Authorization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 7 of 16
*NEMOI etc.
#11 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#12 Maximum Design Pressure=-45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt.
#13 Maximum Design Pressure=-45 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure=-45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#15 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
#16 Maximum Design Pressure=-45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#17 Maximum Design Pressure=-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P12060.02.09-1126
Certificate of Authorization#32455 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 8 of 16
*NEMOI etc.
#18 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#19 Maximum Design Pressure=-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#20 Maximum Design Pressure=-60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure=-60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure=-60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#23 Maximum Design Pressure= -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#24 Maximum Design Pressure=-60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P12060.02.09-1126
Certificate of Authorization#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R30
Polyglass Roof Underlayments; (954) 233-1230 Revision 26: 07/06/2020
Page 9 of 16