Loading...
HomeMy WebLinkAbout20-120 UNICO IR 9/28/2020'24'UNICO AIRCONDITIONINGSIGNPROPOSED OFFICEWAREHOUSE3,000 SFFF: 19.0±50'14'APPROVED SEPTIC SYSTEMLOCATIONPROPOSED STORMWATERMITIGATION AREA25'10'20'56'30' 1 0 '60'PROP DUMPSTERENCLOSUREEXIST DRIVEWAYCUT, TO REMAINEXIST DRIVEWAYCUT, TO REMAIN20'14'R10'R 7 . 5 ' R 1 0 'R10'R5'60°'PAVEMENT10,400 SFLANDSCAPE1,120 SFLAWN3,500 SFLAWN15,180 SFNATURALIZED17,380 SFPROPOSED TEL,ELECTRIC, ETCSERVICES15 '18'LANDSCAPE565 SFROOF3,075 SFEND CURBEND CURBCURB (typ)79'WHEEL STOP(typ)14'15'5'BIKE RACK28'LOADINGZONE52'69'SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSFSFSFSFSFSFSILT FENCE(TYP)SILT FENCE(TYP)EXISTING (ASSUMED)WATER SERVICEAPPROX EXISTINGMETER RISEREXIST RAISEDMEDIANPROPOSEDWATER SERVICEEXISTING TREETO REMAIN (typ)TREE TO BEREMOVED (typ)60'H/C SIGNMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLML12789Sprays QtyGPMT Flow (GPM)Run TimeGallons Manufac tu re r PatternBubble r 351.0035.000:20700Umbrella Pat te rnTotal121182.003640DripQtyGPMT F low (GPM)Run TimeGallons Manufac tu re r24011.53/100'36.740:451653Rainbird XFD D ripl ine , 0.9 gph em it te rs, TotalType6" Pop-UpHunter® PNC 10emitter spacing 12" ,spaced 12" apart 8' R Ful l Ci rc le (360) 8HC40.592.360:20476" Pop-UpRainbird® R-VAN148FC11.171.170:202315' R Part C ircle (270) 6" Pop-UpRainbird® R-VAN1412.782.780:205624' R Ha lf C ircle (180) 6" Pop-UpRainbird® R-VAN18180.9817.640:2035324' R Part C ircle (270) 6" Pop-UpRainbird® R-VAN2415TC421.9180.220:2016046" Pop-UpRainbird® R-VAN2424QC32.768.280:2016615' EST St rip Ser ies 6" Pop-UpRainbird® R-VAN2410.610.610:20126" Pop-UpRainbird® R-VAN24Irrigation Zone L istZone #GPMValveType5261"628726891"1"1"1"1"1"1"1"1"1"1"Spray1181"2171"1"Bubbler1"1"Bubbler3251"4Spray1"SprayIrrigation Zone ListZone #GPMValveTypeSpraySpraySprayDrip 2617278' R Hal f C irc le (180 ) 24TC24HC53.8719.350:20387EST24FC6" Pop-UpRainbird® MPR S tr ip 24' R Ful l Circ le (360) 24' R Part C ircle (90 ) 101"Drip23 15' CST St rip Series91.2110.890:202186" Pop-UpCSTRainbird® MPR S tr ip 17' R Ful l Circ le (360) 21.853.700:20746" Pop-UpRainbird® R-VAN1817FCMLMLMLML ã 2004 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF LANDSCAPE DESIGN ASSOCIATES. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN CONSENT. Scale: Drawn by: Checked by: CADD No.: Date: Revisions Date Comments Landscape Design Associates 25110 NW 182nd Ave High Springs, FL 32643 352-210-5765 ph, www.landscapeda.com UNICO HVAC St Lucie County Irrigation Plan - BubblersIR-011" = 16' KG SM 20-120 ir.dwg 9.18.20Graphic Scale160816ZONEGPMValve118.001"ZONEGPMValve217.001"Well & Pump Station 20'24'UNICO AIRCONDITIONINGSIGNPROPOSED OFFICEWAREHOUSE3,000 SFFF: 19.0±50'14'APPROVED SEPTIC SYSTEMLOCATIONPROPOSED STORMWATERMITIGATION AREA25'10'20'56'30' 1 0 '60'PROP DUMPSTERENCLOSUREEXIST DRIVEWAYCUT, TO REMAINEXIST DRIVEWAYCUT, TO REMAIN20'14'R10'R 7 . 5 ' R 1 0 'R10'R5'60°'PAVEMENT10,400 SFLANDSCAPE1,120 SFLAWN3,500 SFLAWN15,180 SFNATURALIZED17,380 SFPROPOSED TEL,ELECTRIC, ETCSERVICES15 '18'LANDSCAPE565 SFROOF3,075 SFEND CURBEND CURBCURB (typ)79'WHEEL STOP(typ)14'15'5'BIKE RACK28'LOADINGZONE52'69'SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSFSFSFSFSFSFSILT FENCE(TYP)SILT FENCE(TYP)EXISTING (ASSUMED)WATER SERVICEAPPROX EXISTINGMETER RISEREXIST RAISEDMEDIANPROPOSEDWATER SERVICEEXISTING TREETO REMAIN (typ)TREE TO BEREMOVED (typ)60'H/C SIGNRMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLML345678Sprays QtyGPMT Flow (GPM)Run TimeGallons Manufac tu re r PatternBubble r 351.0035.000:20700Umbrella Pat te rnTotal121182.003640DripQtyGPMT F low (GPM)Run TimeGallons Manufac tu re r24011.53/100'36.740:451653Rainbird XFD D ripl ine , 0.9 gph em it te rs, TotalType6" Pop-UpHunter® PNC 10emitter spacing 12" ,spaced 12" apart 8' R Ful l Ci rc le (360) 8HC40.592.360:20476" Pop-UpRainbird® R-VAN148FC11.171.170:202315' R Part C ircle (270) 6" Pop-UpRainbird® R-VAN1412.782.780:205624' R Ha lf C ircle (180) 6" Pop-UpRainbird® R-VAN18180.9817.640:2035324' R Part C ircle (270) 6" Pop-UpRainbird® R-VAN2415TC421.9180.220:2016046" Pop-UpRainbird® R-VAN2424QC32.768.280:2016615' EST St rip Ser ies 6" Pop-UpRainbird® R-VAN2410.610.610:20126" Pop-UpRainbird® R-VAN24Irrigation Zone L istZone #GPMValveType5261"628726891"1"1"1"1"1"1"1"1"1"1"Spray1181"2171"1"Bubbler1"1"Bubbler3251"4Spray1"SprayIrrigation Zone ListZone #GPMValveTypeSpraySpraySprayDrip 2617278' R Hal f C irc le (180 ) 24TC24HC53.8719.350:20387EST24FC6" Pop-UpRainbird® MPR S tr ip 24' R Ful l Circ le (360) 24' R Part C ircle (90 ) 101"Drip23 15' CST St rip Series91.2110.890:202186" Pop-UpCSTRainbird® MPR S tr ip 17' R Ful l Circ le (360) 21.853.700:20746" Pop-UpRainbird® R-VAN1817FCMLMLMLML ã 2004 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF LANDSCAPE DESIGN ASSOCIATES. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN CONSENT. Scale: Drawn by: Checked by: CADD No.: Date: Revisions Date Comments Landscape Design Associates 25110 NW 182nd Ave High Springs, FL 32643 352-210-5765 ph, www.landscapeda.com UNICO HVAC St Lucie County Irrigation Plan - SprayIR-021" = 16' KG SM 20-120 ir.dwg 9.18.20Graphic Scale160816ZONEGPMValve324.671"ZONEGPMValve425.801"ZONEGPMValve527.921"ZONEGPMValve625.721"ZONEGPMValve725.571"ZONEGPMValve817.291"Well & Pump Station 20'24'UNICO AIRCONDITIONINGSIGNPROPOSED OFFICEWAREHOUSE3,000 SFFF: 19.0±50'14'APPROVED SEPTIC SYSTEMLOCATIONPROPOSED STORMWATERMITIGATION AREA25'10'20'56'30' 1 0 '60'PROP DUMPSTERENCLOSUREEXIST DRIVEWAYCUT, TO REMAINEXIST DRIVEWAYCUT, TO REMAIN20'14'R10'R 7 . 5 ' R 1 0 'R10'R5'60°'PAVEMENT10,400 SFLANDSCAPE1,120 SFLAWN3,500 SFLAWN15,180 SFNATURALIZED17,380 SFPROPOSED TEL,ELECTRIC, ETCSERVICES15 '18'LANDSCAPE565 SFROOF3,075 SFEND CURBEND CURBCURB (typ)79'WHEEL STOP(typ)14'15'5'BIKE RACK28'LOADINGZONE52'69'SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSFSFSFSFSFSFSILT FENCE(TYP)SILT FENCE(TYP)EXISTING (ASSUMED)WATER SERVICEAPPROX EXISTINGMETER RISEREXIST RAISEDMEDIANPROPOSEDWATER SERVICEEXISTING TREETO REMAIN (typ)TREE TO BEREMOVED (typ)60'H/C SIGNAAAAAAAAAFFFFAAAAFMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLMLML91011Sprays QtyGPMT Flow (GPM)Run TimeGallons Manufac tu re r PatternBubble r 351.0035.000:20700Umbrella Pat te rnTotal121182.003640DripQtyGPMT F low (GPM)Run TimeGallons Manufac tu re r24011.53/100'36.740:451653Rainbird XFD D ripl ine , 0.9 gph em it te rs, TotalType6" Pop-UpHunter® PNC 10emitter spacing 12" ,spaced 12" apart 8' R Ful l Ci rc le (360) 8HC40.592.360:20476" Pop-UpRainbird® R-VAN148FC11.171.170:202315' R Part C ircle (270) 6" Pop-UpRainbird® R-VAN1412.782.780:205624' R Ha lf C ircle (180) 6" Pop-UpRainbird® R-VAN18180.9817.640:2035324' R Part C ircle (270) 6" Pop-UpRainbird® R-VAN2415TC421.9180.220:2016046" Pop-UpRainbird® R-VAN2424QC32.768.280:2016615' EST St rip Ser ies 6" Pop-UpRainbird® R-VAN2410.610.610:20126" Pop-UpRainbird® R-VAN24Irrigation Zone L istZone #GPMValveType5261"628726891"1"1"1"1"1"1"1"1"1"1"Spray1181"2171"1"Bubbler1"1"Bubbler3251"4Spray1"SprayIrrigation Zone ListZone #GPMValveTypeSpraySpraySprayDrip 2617278' R Hal f C irc le (180 ) 24TC24HC53.8719.350:20387EST24FC6" Pop-UpRainbird® MPR S tr ip 24' R Ful l Circ le (360) 24' R Part C ircle (90 ) 101"Drip23 15' CST St rip Series91.2110.890:202186" Pop-UpCSTRainbird® MPR S tr ip R 17' R Ful l Circ le (360) 21.853.700:20746" Pop-UpRainbird® R-VAN1817FCMLMLMLML ã 2004 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF LANDSCAPE DESIGN ASSOCIATES. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN CONSENT. Scale: Drawn by: Checked by: CADD No.: Date: Revisions Date Comments Landscape Design Associates 25110 NW 182nd Ave High Springs, FL 32643 352-210-5765 ph, www.landscapeda.com UNICO HVAC St Lucie County Irrigation Plan - DripIR-031" = 16' KG SM 20-120 ir.dwg 9.18.20Graphic Scale160816ZONEGPMValve926.501"ZONEGPMValve1022.831"ZONEGPMValve1124.141"Well & Pump Station SpraysQtyGPMT Flow (GPM)Run TimeGallonsManufacturerPatternBubbler351.0035.000:20700Umbrella PatternTotal121182.003640DripQtyGPMT Flow (GPM)Run TimeGallonsManufacturer24011.53/100'36.740:451653Rainbird XFD Dripline, 0.9 gph emitters, TotalType6" Pop-UpHunter® PNC 10emitter spacing 12",spaced 12" apart 8' R Full Circle (360) 8HC40.592.360:20476" Pop-UpRainbird® R-VAN148FC11.171.170:202315' R Part Circle (270) 6" Pop-UpRainbird® R-VAN1412.782.780:205624' R Half Circle (180) 6" Pop-UpRainbird® R-VAN18180.9817.640:2035324' R Part Circle (270) 6" Pop-UpRainbird® R-VAN2415TC421.9180.220:2016046" Pop-UpRainbird® R-VAN2424QC32.768.280:2016615' EST Strip Series6" Pop-UpRainbird® R-VAN2410.610.610:20126" Pop-UpRainbird® R-VAN24Average Water Output:23.22 GPMRun time Method:Full Site in 14h WindowIrrigation Main Line:1- 1/4" PVC Class 200Zone Type and CountQtyRun TimeDrip:32:15TOTAL104:55Irrigation Zone ListZone #GPMValveType5261"628726891"1"1"1"Spray:62:001"1"1"1"1"1"1"SprayBubbler:20:401181"2171"1"Bubbler1"1"Bubbler3251"4Spray1"SprayIrrigation Zone ListZone #GPMValveTypeSpraySpraySprayDrip2617278' R Half Circle (180) 24TC24HC53.8719.350:20387EST24FC6" Pop-UpRainbird® MPR Strip24' R Full Circle (360) 24' R Part Circle (90) 101"Drip2315' CST Strip Series91.2110.890:202186" Pop-UpCSTRainbird® MPR StripR17' R Full Circle (360) 21.853.700:20746" Pop-UpRainbird® R-VAN1817FC111"Drip24ã 2004 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF LANDSCAPE DESIGN ASSOCIATES. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN CONSENT. Scale: Drawn by: Checked by: CADD No.: Date: Revisions Date Comments Landscape Design Associates 25110 NW 182nd Ave High Springs, FL 32643 352-210-5765 ph, www.landscapeda.com UNICO HVAC St Lucie County Irrigation Plan LegendIR-04NTS KG SM 20-120 ir.dwg 9.18.20 ã 2004 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF LANDSCAPE DESIGN ASSOCIATES. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN CONSENT. Scale: Drawn by: Checked by: CADD No.: Date: Revisions Date Comments Landscape Design Associates 25110 NW 182nd Ave High Springs, FL 32643 352-210-5765 ph, www.landscapeda.com UNICO HVAC St Lucie County Irrigation NotesIR-05NTS KG SM 20-120 ir.dwg 9.18.20 MINIMUM RECOMMENDEDIRRIGATION MAINTENANCE PROCEDURES ã 2004 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF LANDSCAPE DESIGN ASSOCIATES. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN CONSENT. Scale: Drawn by: Checked by: CADD No.: Date: Revisions Date Comments Landscape Design Associates 25110 NW 182nd Ave High Springs, FL 32643 352-210-5765 ph, www.landscapeda.com UNICO HVAC St Lucie County Irrigation DetailsIR-06NTS KG SM 20-120 ir.dwg 9.18.20 ã 2004 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF LANDSCAPE DESIGN ASSOCIATES. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN CONSENT. Scale: Drawn by: Checked by: CADD No.: Date: Revisions Date Comments Landscape Design Associates 25110 NW 182nd Ave High Springs, FL 32643 352-210-5765 ph, www.landscapeda.com UNICO HVAC St Lucie County Irrigation DetailsIR-08NTS KG SM 20-120 ir.dwg 9.18.20XFCV Dripline Maximum Lateral Lengths(Feet)Inlet Pressure psi12" Spacing18" SpacingNominal Flow (gph)Nominal Flow (gph)0.60.90.60.92019213625421530289205402337403502484984165039728157347760436309637529XFCV ON-SURFACE END FEED LAYOUTXFCV ON-SURFACE DRIPLINE AT GRADEXFCV ON-SURFACE DRIPLINE IRREGULAR SHAPED LAYOUTXFCV ON-SURFACE DRIPLINE FLUSH POINTDDD ã 2004 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF LANDSCAPE DESIGN ASSOCIATES. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN CONSENT. Scale: Drawn by: Checked by: CADD No.: Date: Revisions Date Comments Landscape Design Associates 25110 NW 182nd Ave High Springs, FL 32643 352-210-5765 ph, www.landscapeda.com UNICO HVAC St Lucie County Irrigation Pump DetailsIR-07NTS KG SM 20-120 ir.dwg 9.18.20 I. Manufacturer and ModelControl station shall be listed under two Underwriters Laboratories sections asfollows:A. UL® 508A - Enclosed Industrial Control Panel - File Number E208950.B. UL® QCZJ - Packaged Pumping System - File Number E143693.II.General DescriptionThis document describes a UL listed skid mounted pumping system with electricalcontrols, pipe manifolds, valves, and all accessories described herein. The pumpstation shall be assembled in a workman like manner with consideration given toconvenience of use, maintenance, and future repairs. All intended features shallwork properly and reliably. All materials exposed to the weather shall be corrosionresistant and shall not be harmed by spraying water. All components mountingsshall be sturdy and solid, with sufficient clearance to safely access, operate, andrepair without significant disassembly of other components. The station shall bemanufactured, tested, then shipped to the site.III.ComponentsA. Electrical and Controls1. ELECTRICAL REQUIREMENTS: The control panel shall be designed to operate onavailable 60 Hertz site power. The entire load presented to the electrical serviceby the pump station shall be: 5.5 amperes @ 460 Volts/3 Phase or 10 amperes @208/230 Volts/3 Phase or 16 amperes @ 230 Volts/1 Phase.2. ELECTRICAL ENCLOSURE & MOUNTING: The control panel enclosure shall befiberglass, NEMA 4X, with stainless steel hardware. All panel penetrations shallmaintain the NEMA 4X rating. This enclosure shall be mounted on the outer wall ofthe station enclosure.3. DISCONNECT: The control panel will have a door interlock disconnect preventingthe enclosure door from being opened unless the power is first turned off. Thisdisconnect shall be a molded case circuit breaker with a minimum AIR rating of18,000 amps @ 480 volts AC.4. CLOCK DEMAND: The pump shall be turned on and off by the irrigationcontroller.5. PILOTS: All pilot operators and trouble indication pilot lights shall be mountedon the outside of the control panel door, and shall be engraved labels, 1 per device.6. FUSELESS: No fuses shall be used anywhere in the pump station unless partof customer requested equipment such as irrigation controllers.7. VOLUTE: When the pump volute reaches a temperature of 115* Fcontinuously for 90 seconds while the pump is running, the pump shall be turnedoff. The pump shall not restart until the RESET button is depressed. A labeled pilotlight mounted on the outside of the control panel door shall indicate that a VOLUTEalarm has occurred.8. OVERLOAD: The pump motor shall be protected against overload per NEC andUL section 508. When an overload condition is detected, the pump motor will beturned off. The pump motor shall not restart until the reset button on the OverloadModule is depressed. A labeled pilot light mounted on the outside of the controlpanel door shall indicate that an OVERLOAD alarm has occurred.9. HAND-OFF-AUTO (HOA) SWITCH: HAND - Pump ON, flow safeties areby-passed except VOLUTE sensor. OFF - Pump OFF - Pump cannot start. AUTO -Pump starts automatically all safeties are active.10.RESET PUSHBUTTON: The RESET PUSHBUTTON shall reset the VOUTE alarmcondition.11.LOW VOLTAGE CONTROLS, LED LAMPS: All sensors inside and outside thecontrol panel, all pilot lights, and all door mounted hardware shall be powered withless than 30 volts. All pilot lamps shall be mounted on the control panel doorexterior and shall utilize LED lamps, incandescent lamps shall not be used.12.CONTROL CIRCUIT PROTECTION: All controls shall receive power from anisolation transformer mounted in the control panel. This transformer shall beprotected on both primary and secondary sides against short circuit, ground fault,and overload by means of properly sized and trip curve designed circuitbreakers. Both primary and secondary sides of the transformer shall includeSURSHUO\VL]HG0HWDO2[LGH9DULVWRUVLQVWDOOHG³OLQHWROLQH´13. VOLUTE HEAT SENSOR: The heat sensor body shall be machined as onepiece from brass stock. The sensor shall provide a single non-adjustable set-pointof 1100F with 5% accuracy. The sensor shall insert directly into the pump volute.B. Station Enclosure and Equipment Pedestals All station components shall beenclosed by a pre-fabricated fiberglass enclosure. The enclosure lid shall be hingedand shall provide convenient access to equipment for repairs and maintenance. Theenclosure shall be vented to provide cooling and shall include a hasp type padlockable latch. The control panel and irrigation controller shall be mounted on anangled aluminum and HDPE pedestals attached to the station base.C. Pump & Motor The pump will be a Horizontal, End Suction, Close Coupled, SelfPriming, Cast Iron Case with Brass Impeller, as provided by Irrigation Craft. Thepump shall provide 50gpm at 45psi station discharge. The pump will be driven by a3 horsepower ODP motor.D. Flow Meter 7KHIORZPHWHUZLOOEHD1HWDILPPRGHO:057´LQline, turbine and will feature a magnetically driven, sealed analog register. Themeter body will be constructed of cast iron with a polyester coating. The meter willindicate flow rate and total flow via analog register display.E. Pump Manifold The pump manifolds shall be constructed of schedule 40galvanized steel. The manifolds shall be rigid and shall include a priming bib,stainless steel glycerin filled pressure gauge, and ball or butterfly isolation valve.Both intake and discharge manifolds shall make provision to be adapted to solventweld PVC piping using roll groove quick connect adaptor nipples.F. Irrigation Controller & Rain Switch The irrigation controller shall be a RainBird ESPME with 10 pre-wired zones. The controller shall be mounted inside thestation on an angled pedestal to facilitate easy use and programming. Thecontroller shall be hardwired to the field with #16 stranded wires, numbered andcolor coded, contained in a UL listed, UF direct burialjacket. This direct burial cable shall continue just outside the station into a splicebox. Field wiring connections shall be made utilizing approved waterproofconnections inside this splice box. The rain switch shall be a click type mounted ateight feet on a rigid galvanized pole, secured to the station enclosure.G. Chemical Injection System A chemical injection system shall be built into thepump station. The injection pump shall be powered from the pump station controlpanel with proper circuit protection operating only when and if the pump operates.The system shall include an injector pump, 40 gallon storage tank, and otherrequired equipment. The injection pump shall be mounted on an aluminum andHDPE pedestal inside the station enclosure. The chemical storage tank shall bemounted on a concrete pad adjacent to the enclosure. The irrigation contractorshall provide chemicals for the injection system as needed to reduce rust stainingduring initial system start up and operation.H. Concrete Pad, Delivery & Installation The station manufacturer shall deliverthe pump station with and bolted to a concrete pad. The irrigation contractor shallLQVWDOOD´VFKHGXOH39&LQWDNHOLQHDQGFRQQHFWWKHSXPSVWDWLRQGLVFKDUJHWRthe irrigation mainline. The site electrician shall install electrical service to thepump station.I. Operation Manual The station manufacturer shall provide an operating manualupon request. This manual shall be specifically written for the station. This manualshall contain at minimum the following: Explanation of station operation, controlwire schematic, trouble-shooting guide, manufacturer's name, address, andtelephone numbers, wire tightening torque values for supply connections.J. Start-up & Calibration The pump station manufacturer shall provide on siteStart-up and Calibration services after the equipment is installed.K. Warrantee The station manufacturer shall provide a warrantee covering laborand materials, both to the contractor and also directly to the property owner, for aperiod of one year excepting normal maintenance, abuse, vandalism, and naturaldisasters such as flood, hurricane, lightning, wind, etc. Consequential damages dueto station malfunctions shall not covered by this warrantee.44"48"