Loading...
HomeMy WebLinkAboutCALZADILLA.1.2020.0923++++++++++++++++++++++++++++++++++++++++20'25'10'20'++++++++++++++++++++++++++++++++++ ++++++++ ++++++ ++++++++++++++DEMOLISHEDBUILDING (typ)DEMOLISHEDBUILDING (typ)EXIST SPOTGRADE++++1 5 EXISTING CONDITIONSNOTES1. SURVEY INFORMATION PROVIDED HEREON FROM A MAP PREPARED BYWATSON/KILLANE, DATED LAST REVISED SEPTEMBER 9, 2017.2. ADDITIONAL SURVEY DATA PROVIDED BY STEPHEN MARSHALL, LS.3. FOR THE PURPOSES OF STORMWATER MANAGEMENT, THE "DESIGN POINT" ISTAKEN AS THE INTERSECTION OF INDIAN PINES BOULEVARD AND THE TURNPIKEFEEDER ROAD. THAT IS RUNOFF FROM THE PROPERTY ULTIMATELY REACHESTHE DESIGN POINT. MORE SPECIFICALLY, THE EASTERLY SIDE OF THE SITEFLOWS TOWARDS A SWALE ALONG THE PROPERTY LINE BEFORE REACHING THERIGHT OF WAY OF THE THE FEEDER ROAD, WHILE THE WESTERLY PORTION OFTHE PROPERTY FLOWS TOWARDS THE INDIAN PINES BOULEVARD AND TO THEINTERSECTION WITH THE FEEDER ROAD.4. THERE IS AN EXISTING DEPRESSION LOCATED ALONG THE EASTERLYPROPERTY LINE WHICH ACCUMULATES STORMWATER RUNOFF FROM A SMALLPORTION OF THE EXISTING PAVED AREA. IT IS APPARENT THAT THIS AREAPROVIDES SOME MITIGATION THROUGH INFILTRATION.5. BASED UPON EXISTING TOPOGRAPHIC CONDITIONS, A SIGNIFICANTPERCENTAGE OF THE CURRENT PAVED AREAS FLOWS TOWARDS A SWALEALONG THE NORTHERLY EASTERLY PROPERTY LINE. THE SWALE FLOWS FROMEAST TO WEST AND DISCHARGES AT THE RIGHT OF WAY LINE OF THE TURNPIKEFEEDER ROAD.6. THE SITE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TOPROTECT THE EXISTING SWALE AND VEGETATION ALONG THE EASTERLYPROPERTY LINE DURING CONSTRUCTION.7. ALL DISTURBED AREAS - OTHER THAN THOSE THAT WILL BE PAVED SHALL BERESTORED WITH TOPSOIL AND SOD. SITE DATAOWNER: OSCAR CALZADILLAUNICO AIR CONDITIONING COMPANYPROPERTY ADDRESS: 3701 AND 3707 OKECHOBEE RD, FORT PIERCE, FLORIDAAREA: 53,578.8 SF (1.23 ACRES)PARCEL ID #: 2417-704-0063-000-6, 2417-704-0061-000-2ZONING DISTRICT: CG (COMMERCIAL, GENERAL)EXISTING LAND USE: VACANTPROPOSED LAND USE: COM (COMMERCIAL)BUILDING AREA: NAPARKING RATIO: NAFEMA FIRM CLASSIFICATION: ZONE X - AREA OF MINIMAL FLOOD HAZARDPLATE #12111C0186J, DATED 2/16/12UNICO AIR CONDITIONING 3701 & 3707 OKECHOBEE RD, FORT PIERCE, FLORIDA 34951 Date: Nathaniel J. Holt, P.E.HOLT ENGINEERING & CONSULTING, PA 540 NW UNIVERSITY BLVD., SUITE 105 PORT ST LUCIE, FLORIDA 34986 (772) 204-9550 Project Number: CALZ-0319 SHEET: of Original Date: June 5, 2020 5 2 1 3 4FL REG #: 63213 PROJECT NUMBER: August 5, 2020 Update Tree Survey August 31, 2020 Misc September 23, 2020 Submission to Engineering