Loading...
HomeMy WebLinkAboutPA FL17420-R4Tf w: Business 4ProfessionalRegulation p BCM Harrle Lo pn I User Registration � Hat TapiCs E Submlt Surcharge Slats & Facts + F[lhli=iCn5 Conrad L# E BM Site Map ? Links Search 14 dba r Product Approval USER: Public User Pr act Aonrov�l Nfenu � Prodyct or AppIrcation-Search � gppl�ation List I Application Detail R # FL17420-114 Application Type Revision Code Version 2p17 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phore/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg-keefer@oweriscornirig.com Authorized Signature Greg Keeler greg. keeler@owenscornirtg.com Technical Representative Address/Phone/Ernaif Quality Assurance Representative Add ress/Phone/Emai I Category Roofing Subcategory Underlayments Cornpliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - HardCOpy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12131/2020 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of independence FL17420. R4 CQI QCR140,04.4 2017_Ff3C EaLRgport PrQArmor fin aLpdf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1507.1.1 Date Submitted Date Validated Date Pending FSC Approval Date Approved a FL # Model, Number or Name 17420.1 PrOArmor Limits of Use Approved for use in HVHZ: No I Approved for use outside HVHZ; Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report far limits of use. 09/30/2017 10/03/2017 10/04/2017 12/12/2017 Description Synthetic underlayment for use with asphalt shingles in steep slope roofing I Installation Instructions FFL174� R4 II OCR 4 04.4 17 Ev ProArmor Fin@i,pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party_ Yes Evaluation Reports FL174�R4 ApCRj4004.4 2017 1 Eval g Pr4Armor final.�df Created by Independent Third Party: Yes Back Next (fin act lis :: 26 BI i tone R a Tall h ee FL 239 Phone: 850-487-1824 The State of Rorlda is an AA/EEO employer. Cooviight 204)7-2D33 States of Florida. :: Privacy Statement :: r b9 - to n :: R__gfUnd SUtemen Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the oifiCe by phone or by traditional mall. If you have any questions, please contact SSo.487.1395. *pursuant t ido section 455,275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an small address if they have one. The smalls proved may be used for official cammunicatien with the licensee. However emalf addresses are public record. If you do not wish to supply a Personal address, please provide the Department with an email address which can be made available to the public, To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: u ® FS Credit Card Safe � Certificate ofAuthion 29824 17520 Edinburgh DriveCREEK Tampa, FL 33647 TECHNICAL. SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 6"' EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued September30, 2017 1 Owens Corning Parkway Toledo, OH 43657 (800) 438-7465 www.owenscominq.com Quality Assurance: Intertek Testing Services NA, Inc. (QUAI673) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year I nte rtek Testing Services NA Ltd. (TST1509) 102389161COQ-002A AC 188 2012 IntertekTesting Services NA Ltd_ (TS71509) 102389161COQ-003b ASTM E 108 2011 Intertek Testing Services NA Ltd_ (TST1509) 102389161 COQ-004 ASTM D 226 2009 PRI Construction Materials Technologies (TST5878) OCR-259-02-01 ASTM D 1970 2015a PRODUCT DESCRIPTION AND APPLICATION ProArmorlm A mechanically attached, synthetic underlayment consisting of a woven polypropylene base with a non -woven polypropylene laminate on the topside of the underlayment, and a coating on the back side (nominal weight = 2.15 lb1100f ). The underlayment shall be used an alternative to ASTM D 226, Type II roofing underlayments and has demonstrated a minimum tear strength of 20 pounds when tested in accordance with ASTM D 1970. The product is supplied in 9.2-sq rolls with nominal dimensions of 4-ft x 250.5-ft. Unless otherwise noted, the following application details shall be followed for New and Existing construction. See manufacturer's installation instructions for further detail. Roof Deck: The roof deck shall be constructed of closely fitted wood sheathing for new or existing construction_ Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than '/8' gap at abutting joints. Attachment method: Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and manufacturer's installation instructions. Allowable roof coverings: Mechanically attached roof systems as prescribed in FBC Section 1507.1.1_ OCR14004.4 FL17420-R4 Page 1 of 2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not o--- ifi 1j" AA_ ­_A ke in Ak. CREEK TECHNICAL SERVICES, LLC LIMITATIONS OWENS CORNING ROOFING AND ASPHALT LLC ProArmorTm 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. E) Roof slope limitations shall be in accordance with FBC requirements. 7) The underlayment may be used as described in other current FBC product approval documents. 3) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 9) The underlayment shall not be installed over existing roof coverings. 10) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in success courses installed up the deck it a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's applicatior instructions. 11) The underlayment shall not be exposed on the roof deck for longer than 30 days. 12) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code fit" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. [if R if No 74021 aZ ��•: STATE OF Eu� .d. CERTIFICATION OF INDEPENDENCE 2017.09.3 0 15:21:14 -04'00' Zachary R. Priest, P.E_ Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, ner will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation, Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest; P-E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14004.4 FL17420-R4 Page 2 of 2 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not