HomeMy WebLinkAboutPA FL10674-R15Business • IF . ion NEI=
BC15 Nome I Log In User RegistraticM E Hot Tapirs S,.L.jt Surcharge i Stars & Facts ; Publications Contact us i BCLS Site hap i Links I Search j
d. bor
Product Approval 4
usER: Public user
Product Amroral Menu , Product or Apollcation Search > 4plicatltln LiS } Application Detail
FL #
FL10674-R15
Application Type
Revision
code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Emdil One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
g reg. keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Niel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OF 43659
(419)376-8360
rnei.sancrant@owenscorn'ig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert I.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologles, LLC
Quality Assurance Contract Expiration Date 01/01/20gg
Validated By lohn W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL10674 R15 CaI 201 01 COI NIEMINEN.Q�-f
Referenced Standard and Year (of Standard) Standard Year
ASTM d1970 2015
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
06/15/2019
Date Validated
08/15/20I9
Date Pending FBC Approval
08/21/2019
Date Approved
10/15/2019
Summary of Products
FL It
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
3-tab, 4-tab, 5-tab, laminated, starter and ;hip & ridge
Shingles and Starters
shingles
Limits of Use
Installation Instructions W
Approved for use in HVHZ: No
FL10674 RL; II 2619 Qa FINAL_EP_QQ__ASPHALT
Approved for use outside HVHZ: Yes
SHINGLES F1_10674-R15 pd
Impact Resistant: N/A
Verified By; Robert]. M. Nleminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other. Refer to ER, Section S.
Evaluation Reports
FL10674 209
915_pF 08 E1NAi__ER_0f__A5PHALT
SHINGLES EL14674-R15,,pjjf
Created by Independent Third Party: Yes
Banc Next
Contact Us :: 260L Blair Stone Road, Tallahassee FL 37399 pl]gne: 850-467-1374
The State of Florida is an AA/EEO employer. QpYright 20OZ-2QZ3Florid-a- :: Prlygcy Statement :: AQCe551billtV Statement :: R2fund 5taterrient
Under Florida law, email addresses are public records. IT you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 650,487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October I, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may he used for official Communication with the licensee. However email addresses are public record, if you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter
455, ES., please dick here_.
Product Approval Accepts:
M 54 ® sCt
Credit Caret
Safe
NEMO I etC.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
0 (2D3) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
Owens Corning Evaluation Report 037940.02.12-R10
One Owens Corning Parkway FL10674-R15
Toledo, OH 43659 Date of Issuance: 02/06/2012
(740) 404-7829 Revision 10: 08/15/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Cade sections noted
herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / 11905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality
Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance orthe production facility location(s), NEMOJetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by: ,.•�,:';"'� =•r, "
Robert J.M. Nieminen' P.E. �r� The facsimile seal appearing was authorized by Robert
r� �,, p,�,s.:
- ���, �:^•»�; c$.E� Nieminen, P.E. on 08/15/2419. This does not serve as an
Florida Registration No, 59166, Fforida DC4ANE1983 °` elettrOnkcallysigned document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOletc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2_ NEMO ietc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a buildingcode evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in aryway,the Designerof Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
02018, NEW ETC, LLC
UN
NEMO ] etc.
ROOFING SYsTEms EVALUATION,
ProductCatei;M:
Roofing
Sub -Category:
Aspha It Shingl es
Compliance Statement:
Owens Canning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 61 Edition (2017) Florida Building Code and Florida
Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation
Requirements and Limitations / Conditions of Use set forth herein.
..2. STANDARDS:
Section
Property
Standard
Year
1507.2.4, R905.2.3
Physical Properties
ASTM D1970
2015
1507.2.5, R905,2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7A, R905.2.6.1
Wind Resistance
ASTM D7158
2011
Enti
Examination
Reference
Date
Owens Corning
Declaration
Fqulyalency Declaration
08/06/2019
PRI (TST5878)
ASTM D1970
OCF-382-02-01
10/24/2017
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC (TST9628)
Physical Properties
❑GCA20263
04/18/2006
UL LLC (TST5628)
Wind Resistance
IICA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
021ID17014
UL LLC (nT9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (7S79628)
Physical properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
PRI (QUA9110)
Quality Control
Service Confirmation
04/05/2020
4.1. ACCESSORY STARTERS:
4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets
ASTM D3462.
41.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip,
nominal 7.2-inch wide x 33-ft 4-inch long roll, for use with asphalt shingles. Meets ASTM D1970.
4.2 ASPHALTSMNGMS:
4.2.1 Classic" and Supreme' are fiberglass reinforced, 3-tab asphalt roof shingles. Meets ASTM D3462.
4.2.2 Berkshire' are fiberglass reinforced, 4-'tab asphalt roof shingles. Meets ASTM D3462.
4.2.3 Duration®, TruDefinitiong. DL ration , Duration` Premium Cool, TruDefinition Duration Designer Color Collection,
TruDefinition` Oakridge% Oakridge= and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof
shingles. Meets ASTM D3462.
4.3 HIP & RIDGE SHINGLES:
4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRidge® Hip &Ridge Shingles with Sealant, ProEdgeO Hip & Ridge
Shingles and WeatherGuard° HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
Meets ASTM D3462.
NEMO ETC, LLC Evaluation Report 037940.0Z.12-R10
Certlffcate a/Aurhadzotlon #32455 6- EDITION (2017) F8C NON-HVHZ EVALUATION FL10674-RlS
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
13-'1 ..; a n
(NNEMOJetc.
5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Wind Classification:
5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones
UP to Vasd =150 mph (V.It =194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.2 Starter5trip Shingle, Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip
& ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to
ASTM D3161, Class F, indicating acceptable use in all wind zones up to Vas,, = 150 mph (V It - 194 mph). Refer to
Section 6 for installation requirements to meet this wind rating.
5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6.11 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 611320-3, per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.7.6 cr R905.2_5. Staples are not permitted_
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
Feii undedaymuu[
adW
NY N I.Aa d
2'-3' ITSM ema
]nstaN frsst �� 5eNseahnp adhesive
Startar Strip._......-„_.,r_ w poshianed a3ona ears
ah��enviih ..
8'rwnwud �
Sim$' �s7>Q�yls wsrhanps eaves and rakes'n'}5"
Figure 1: Minimum Nailing, Starter Strip
Figure 2: Minimum Nailing, Starter Strip Plus
NEW ETC, LLC Evaluation Report 037940.02.12-R10
Certificate ofAuthorizetion # 2455 67" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/1.512019
a.ao 2 .,F s rL
(NNEMOjetc.
5.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Deck
Drip edge
IIf�
Self-sealing adhesive
positioned along eaves
Figure 3: Starter Shingle Roll
Underlayment
edge
Starter Shingle Roll adhered
directly to underlayment and
primed drip edge
6.3 ASPHALTSHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
> Berkshire' shingles require minimum five (5) nails per shingle.
WeatherGuard° HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Classic® & Supreme:
Normal Mansard ar Area pare
Winn! Areas High VWad desvanes r
Area Para viantos narmalas Areas rientos Mertes
T.
sr'Exposure
Esposicion
Figure 4: Minimum Nailing, Classic & Supreme
(Standard Size)
Normal Mansard or Area pare
Wind Areas Highwind deavanes r
Area pare vientai narnmras Area* vientas tuertes
1.
Al— 7; fT' z"- -(H] r2" 1"�I
72 t
5 5/9" Exposure
Exposlcidn
Figure 5: Minimum Nailing, Classic & Supreme
(Metric Size)
MEMO FTC, LLC Evaluation Report 037940.02.I2-1110
Cert+fcote ofAurhorizarfon #32455 V' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS
Owens Coming Asphalt Roof Shingles Revision 10: 08/15/2019
-- n n F 9 n
5.3.1-2 Berkshire®_
Figure 6: 5-Nail Pattern, Berkshire
CN)NEMO I etc.
Figure 7: 6-Nail Pattern, Berkshire
seals t ship
to&A&$01 kr
NL S Sh S h 8 Y� S Yi
[
2 Ssphalttooling cenient
Cemafe & ]echoA ashho
Figure 8: Mansard or Steep Slope Pattern, Berkshire
MEMO ETC, LLC Evaluation Report 037940.02.12-R10
Cerdf?cote of Authorization #32455 6'' EDITION (2017) 170C NON-WVH2 EVALUATION FL10674-R15
Owens Corning Asphaft Roof Shingles Revision 10: 08/15/2019
0—t..r 16
(NNEMOjetc.
6.3.1.3 Duration® TruDefnition' Duration Duration'' Premium Cool & TruDeiinitiori Duration' Designer Color Collection:
4-Nall Fastening Pattern
SureNaim fastening area wwh
AHazy Typical� �uns e��u,o�urawassrxns cones,µ saner
6-1f8" yg/g"
egwew.=F1 7
Figure 9: Standard 4-Nail Pattern, Duration
Fgure 1p:'&lail Pattern, Duration
Figure 11. Mansard or Steep Slope Pattern, DOration
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Cefftftate vfAuthoe*adon 932455 V EDITION (2017) FBC NON-14VHZ EVALUATION FL10674-R15
[swans Corning Asphalt Roof Shingles Revision 10: 08/15/2019
o...-.. c —4: in
6,11.4 TruDefinition�Oakrid e® Oakrid e®:
4 mall Pattom
F.sgu,?ma can d elms
t` �•
;E-- 12. re --�
5 5� Exposure 5 50 Exposure
EV00d6rt de 55 Sptig. GQIVLU Exposicbn de 5 $/8pufg.
Figure 12. Standard 4-Nail Pattern, Oakridge
6 Nail Pattern
Esq uama ran S davos
t V
iz-
Nalls
5 5f6" Fkpamfe Cbvm 5 5i8" Expmra
EW05fron de 5"Prfg. Expasidarr rk 55/8 pdg.
Figure 13: 6-Nail Pattern, Oakridge
Fastening for Slopes Greater Than 21:12
sumaRs faetmIng area wletn
Halt' rypll
1' 32" =p• f•
'-�'� YI+mCmuM SrS.N�T� lu.. +L9llWvalwm - ■owcCa�nusuovu� a
P ti'8" i-SJ8^
Fouo 9• spots &Asphalt Roofing Cement
Figure 14- Mansard or Steep -Slope Pattern, Oakridge
tONEM0 I etc.
NEW ETC, i.LC Evaluatior Report 037940.07.12-R10
Certificate afAutharfzntfon #32455 e" EDITION (2017) FBC NON-HVH2 EVALUATION FL10674-RIS
Owens Coming Asphalt Roof Shingles Revision 10: 08/15/2019
- 9 -* in
5.31.5 WeatherGuard* HP:
f~ 12 1 dj.
518"F�va�ta
QSia6tl d! $ 5$ 7QkJ
55r8" rposvt
ixixui de's iE guJ1.
Figure 15: 6-Nail Pattern, WeatherGuard
HP
6Nag Pattern
EsWenm con 6 ciavos
Hull 6 V8' from boltiom
of shiroo
5 W' ExgO re 6 fasteners
Owe a 6 118 piny. de la
parts i0feriaf de la teja
EWS664 de 5 5,8 twig. 6 SI etadores
Four 1" SpDUof Asphalt Roof Cernerit
Cuatro pumas de cement® de tedw de asfa(fa de 1 p*da
Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP
C(4)NEMO I etc.
6.4 HIP & RIDGE SHINGLES:
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
Y~ Berkshire° Hip and Ridge Shingles with Sealant and DuraRidg0 Hip & Ridge Shingles with Sealant require
minimum two (2) nails per shingle.
➢ WeatherGuard' HP Hip and Ridge Shingles and Pro Edge® Hip & Ridge Shingles require minimum four (4)
nails per shingle_
Refer to Owens Corning published information on wind resistance and installation limitations.
MEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certiflcote of Authorization #32455 6"' EDITION (2017} FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
oa..c v M 1.
(NNEMOjetc.
6.4.1.1 Berkshire' Hip & Ridge with Sealant and DuraRidlgeO Hip & Ridge Shingles with Sealant:
Fig. A
Prevailing Wind direction
- Direccian del viento predominante
Figure 17: Isometric View, Berkshire and DuraRidge
6.4.1.2 WeatherGuard® HP Hip & Ridge Shingles:
Fig' B
Top View
Vista superior
Nail
2W 1 Clam
yOwens Corning SweNail" w
I
I
i_
dl�
C )
�I�
I
I
�- i 2"
Figure 18: Plan View, Berkshire and DuraRidge
Fig. C Hip & Ridge Shingle Fastening
Top lo6v
td91IS Nails
2. �
to i
i
1" t�"�
A
5' acpasore i
I
Figure 19: Isometric View, WeatherGuard HP Hip & Ridge Figure 20: Plan View, WeatherGuard HP Hip & Ridge
MEMO ETC, LLC Evaluation Report O37940.02.12-R10
Certifemte ofAutharizutiori#324SS 6 " EDITION (2017) rac NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Raaf 5hingles Revision 10-, O8115/2019
b—a-fin
6.4.1.3 ProEd e® Hip & Ridge Shingles:
Prevailing
Wind Direction Sealant Strip
.� 6" Exposure
Fasten 7%"
00uerExposed
Fosftaers wish
Rao! Cement
Figure 21: Isometric View, ProEdge
(NNEMOjetc.
Standard 4Exp.L
fastening
Pattern
2'Z''!2' {Sealant
Figure 22: Plan View, ProEdge
7. LABELING'
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1 / R905.2.6.1.
BUILDINGa
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation
of this product.
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3
QA requirements.
IQUALITY
PRI Construction Materials Technologies, LLC—QUA9110; $13 621-5777; bwilson@pricmt.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 037940A2.12-RID
Certificate ofAuthoroationR32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FLID674-RIS
Owens Corning Asphalt Roof Shingles Revision 10; 09/15/2019