Loading...
HomeMy WebLinkAboutHealth Department, final approvalAPPLICATION #:AP1412648 STATE OF FLORIDA PERMIT #:56-SF-1947072 DEPARTMENT OF HEALTH DOCUMENT # FI 1495929 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM : PAID:10/01/2019 ,y CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE GOp WE 15.00 FEE PAID:1 RECEIPT #:56-PID-4164355 APPLICANT: John Testa AGENT: PROPERTY ADDRESS: 2469 Johnston Rd Fort Pierce, FL 34951 LOT: BLOCK: SUBDIVISION: ID#: 1334-501-0002-000-1 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] (01] TANK SIZE [11 1050.00 [21 [ ] [27] SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] (281 DITCHES FT [ ] 1031 OUTLET DEVICE [ ] [291 PRIVATE WELLS 100 FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] [301 PUBLIC WELLS FT [ ] (051 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [06] LEGEND 1. 70-156-10DC3 2. [ ] [32] POTABLE WATER 60 FT [ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 7 FT [ ] [081 LEVEL [ ] [34] PROPERTY LINES 38 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1] 528 [2] SQFT [ ] [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1, 5.00 2. [ ] [38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [39] STABILIZATION 09/23/2020 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 16.00 [ ] [401 UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] (221 FILL AMOUNT I. ] [47] CONTRACTOR THOMAS W HINKLE (HINKLE [ ] [231 FILL TEXTURE [ ] [481 OTHER MINERAL AGGREGATE [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] 1491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. / St. Lucie CHD DATE: 09/02/2020 CONSTRUCTION [ APPROVED DISAPPROVED � ' Envir me=Specialistn J Ingram(ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: �°i��-� St. Lucie CHD DATE: 09/23/2020 Environmental Specialistl,,Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) I/f/ DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1412648 EID1947072 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1412648 PERMIT #:56-SF-1947072 DOCUMENT # : FI 1495929 DATE PAID: 1010112019 FEE PAID:115.00 RECEIPT #:56-PID-4164355 The system is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of 400 3pd• New ST, filter, and 5x32' long TRENCH DF installed. 480sgft + header and footer = 528 stft. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for mound system and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1412648 EID1947072