Loading...
HomeMy WebLinkAboutDuct workPerformed for: KURT ELLMERS 6016 SPRUCE DRIVE FT. PIERCE, FL 34982 QUICK CALCS, INC. 317 ST. LUCIE LANE FT, PIERCE, FL34946 Phone: 772-466-6799 QUICKCALCS@AOL.COM Scale:l : 100 Page � RIgMSuite� Universal 2019 19.007RSU08101 20248eP2813:0625 ...nghlsoft HVAC)ELLMERS, KURTmp Project Summary Date: wrightsoft° Entire House 6y. QUICK CALCS, INC. Project Information Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Insidedb 70 OF Inside db 75 OF DesignTD 28 OF DesignTD 15 OF Daily range M Relative humidity 50 Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20463 Btuh Structure 24611 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cim) 0 Btuh Central vent (0 cim) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 20463 Btuh Use manufacturers data n Rate/swingg multiplier 0,95 Infiltration Equipmentsensible load 23380 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1968 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ft2) 1570 1570 Equipment latent load 1968 Btuh Volume (fN) 14130 14130 Alrchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 25348 Btuh Equiv. AVF (cfm) 89 47 Req. total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade LENNOX Model Cond XC21-036-230-10 AHRI ref Coil CBA38MV-036-230'++TDR AHRI ref 201907209 Efficiency 80AFUE Efficiency 13.0 EER,19 SEER Heating Input 0 Btuh Sensible cooling 24920 Btuh Heating output 0 Btuh Latent000ling 10680 Btuh Temperature rise 0 OF Total cooling 35600 Btuh Actual air flow 1187 cfrn Actual air flow 1187 cfin Airflowfactor 0,058 cfinBtuh Airflowfactor 0.048 cfinlBtuh Static pressure 0.08 in H2O Static pressure 0.08 in H2O Space thermostat Load sensible heat ratio 0.93 Calculations approved byACCAto meet all requirements of Manual J Sth Ed. wrightsoft' 202f}Sep-2813:04:52 ��-- • � -•-• �- - Right-SUIe®Wiversa1201919.0.07 RSUOB101 Page 1 M�4p ...ICK\Uo eM\WngM oft WAGTLLMERS, KURT.np Laic=MA FroOf or fares: N -�- wrightsofte Duct System Summary Job Entire House By: QUICK CALCS, INC, 317 ST. LUCIE LANE,FF. PIERCE, FL 34946 PMne: 772-4666799 Em II:OUICKCALCSQAO . For: KURT ELLMERS 6016 SPRUCE DRIVE, FT. PIERCE, FL 34982 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.08 in H2O 0 in H2O 0,08 in H2O 0.040 / 0.040 in H2O 0.056 in/10011 1187 cfm Cooling 0.08 in H2O 0 in H2O 0.08 in H2O 0.040 / 0.040 in H2O 0,056 in/100ft 1187 cfm r. _ ,%SupplyBrancy� ETeta�l Tak�le .. , Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (it) Ftg.Egv Ln (it) Trunk BATH IT 1915 111 106 0.056 6.0 Ox0 VIFx 29.0 115.0 st1 BATH IT 476 28 13 0,060 4.0 Ox0 VIFx 18.4 115.0 st2 BEDROOM In 2544 148 108 0,056 TO Ox0 VIFx 28.1 115.0 st2 BEDROOM h 1690 98 70 0.059 TO Ox0 VIFx 20A 115.0 st2 BEDROOM4 c 1720 73 83 0.077 7.0 Ox0 VIFx 9.2 95.0 CLST. In 492 29 14 0.058 4.0 Ox0 VIFx 22.4 115.0 st1 KITCHEN c 3475 108 168 0,058 8.0 Ox0 VIFx 23.8 115,0 st1 LIVING h 3242 188 170 0.057 8.0 Ox0 MFx 26.0 115.0 st1 LIVING ROOM c 3269 119 158 0.073 9.0 Ox0 V1Fx 15.2 95.0 LIVING ROOM -A c 3269 119 158 0.077 9.0 Ox0 VIFx 9.2 95.0 MASTERBEDROOM h 2895 168 140 1 0.056 8.0 Ox0 VIFx 27A 115.0 st1 ��� ��` � � � � ��Supply�Trunk Detail Table " I� Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfrn) (cfrn) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 273 191 0.056 501 10.0 0 x 0 VinIFIX sit PeakAVF 603 597 0.056 768 12.0 0 x 0 VinlFIX Bol�talk values have been manually overridden '�'�' WP19flY50Tt� 2020-Sep-2813:04:52 ��...R.,.,,�...n...,�...Nm Rigid-SJIe®Unversa1207919.0.07 RSU08707 Pagel ...ICK\Doamerts\Wngl�isofl HVAC\ELLMERS,ICURrnp CaIc=MJB Frori Door fares: N ::ve � Return Brancli:Defail Name Grille Size (in) Htg (Cfm) Clg (Cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Dud Matt Trunk rb1 Ox0 192 241 0 0 0 0 Ox 0 VIFx rb5 Ox0 217 228 0 0 0 0 Ox 0 MFx rb3 Ox0 296 338 0 0 0 0 Ox 0 MR rb6 Ox0 29 __ 14 0 0 0 0 Ox 0 MFx rb7 Ox0 111 106 0 0 0 0 Ox 0 VIFx rb2 Ox0 168 140 0 0 0 0 Ox 0 MFx rb4 Ox0 175 121 0 0 0 0 Ox 0 MFx -Fld- wrightsofte 2020.5ep-2813:04:52 �: .,..�.�„„G... ...,.yr••-�M ftigM-SUie®Unversa12019190.07 RSU08101 Paget %1C+Cf� ...ICK�Uoonrerts\WrlgMsoI1 HVACfELLMERS, KURT.rip Caic=MJB Frcrt Doof faces: N