HomeMy WebLinkAboutResubmit Generator Permit - Crippen Residence Generator Permit 24909 Orange Ave_000112 9/29/20P anning & Development Services wilding & Code Regulapon Division 2300 Virginia Avenue Fort Pierce. FL. 34982 PROPERTY INFORMATION Address: 24909 Orange Ave City / State / Zip: Fort Pierce, FI 34945 Parcel #: 2112-441-0002-000/9 Zoning: AG-5 APPLICATION INFORMATION Permit Number: 2008-0759 Permit Type: GENERATOR, RESIDENTIAL CONTRACTOR INFORMATION Contractor Name: Daniel J Stubbs Business Name: S & W Electric Inc Business Addr: 501 W Coker Rd City / State / Zip: Ft Pierce, FI 34945 REVIEWS AND COMMENTS Review Type Status FRONT COUNTER REVIEW COMPLETE Comment: NOTIFIED FOR PICK UP Comment: PLANS EXAMINER ELECTRIC Comment: 9/24/2020 PENDING REVIEW COMMENTS Page 1 Owner(s): Lindsey A Crippen / Scott S Crippen Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: Email: Stu boutelectric@Aol.Corn Reviewed By Date Started Date Completed Date Released Ellen Vaughn 8/29/2020 8/29/2020 8/29/2020 INCOMPLETE Doug Harvey 9/24/2020 SERVICE AND NON -SERVICE NOT TO BE IN THE SAME RACEWAY OR CABINET. GENERATOR IS NON - SEPARATELY DERIVED AND CONDUCTORS FROM THE GENERATOR ARE FEEDERS NOT SERVICE, DRAWING SHOWS THE SERVICE AND FEEDERS IN THE SAME CONDUIT AND ENCLOSURE. PLEASE CORRECT. PROVIDE AIC RATINGS FOR VERIFICATION OF EQUIPMENT 1 v Q a O 5y 7 c l- ;O �O �c c c �j 0 G P 'D Y Electrical Contractor: _� 4 �,J ec I r Phone No.: 7 7;L �Z 6 t l , jy 416 6 Fax No.: Project: Gr, o ram, /2 e S Location: k C? Existing Service Feeder Size: 2/ 0 G (/ Existing Panel Size: L/ 0 , Main Breaker Size: Number of Breakers: Existin Loads 1 a-S1' Sq. ft. x 3 watts per sq. ft. r 2 V watts oZ Appliance cir. @ 1500 watts each 3C0vwatts / Laundry cir. @ 1500 watts each / 5-00 watts G n S Range C� S kw watts Dishwasher and disposal @ 1500 watts each watts Microwave @ 2000 watts Q-Coo watts c s Water heaters watts Tankless water heater watts (�� Dryer @ 5 kw watts / Refrigerator @ 1500 watts / 5 o 0 watts Bathroom 1 @ 1500 watts S/ p 0 watts Sprinkler Pump watts Other _ 4 watts Other watts Other watts Sub 'Total O?V watts New Loads Pool pump watts _ — Pool light watts Heat pump watts Chlorine generator watts Air blower watts Boatlift watts Other watts Other watts Other watts Total watts First 10 kw @ 100% watts Remainder @ 40% p 3 O watts A/C heat @ 100% I 0,,POO watts Total watts = o Divided by 240 volts = aZ Amps Prepared by: prmi lel / S i L%_� Date.-y Cable Engineered by Draka 600 Volt, Tray Cable PVC/Nylon Insulated Circuit Conductors Overall PVC Jacket A B C D E Components A: (3) - #3 AWG Class C stranded, soft drawn, bare copper circuit conductors w/40 mils (1.02 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 6 mils (0.15 mm) nylon applied directly to the surface of the insulation. B: (6) - #18 AWG Class K stranded, soft drawn, bare copper conductors w/15 mils (0.38 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 4 mils (0.10 mm) nylon applied directly to the surface of the insulation. C: (1) - #8 AWG Class C stranded, soft drawn, bare copper grounding conductor w/30 mils (0.76 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 5 mils (0.13 mm) nylon applied directly to the surface of the insulation D: Mylar binder tape. E: 80 mils (2.03 mm) of heat and moisture resistant, polyvinyl chloride (PVC) jacket. Print Legend (UL) E60544 POWER AND CONTROL TRAY CABLE TYPE TC-ER-JP 3 AWG (26,7 mm2) 3/C + 8 AWG (8,37 mm2) 1/C GROUND THWN CONDS & 18 AWG (0,82 mm2) 6/C TFFN CONDS 600V 75C DRY/75C WET OIL RES 1 SUNLIGHT RESISTANCE DIRECT BURIAL JOIST PULL GENERAC P/N 1722 "sequential footage print' Physical Characteristics Cable Weight: 900 Ib/mft (1339 kg/km) Copper Weight: 577 Ib/mft (859 kg/km) Nominal Cable OD: 0.980 in (24.9 mm) e DATE CHANGE DETAIL v 0 02/03/17 New Issue 2 3 Approvals: I Engineering: I I Final: Draka Cableteq USA Inc. reserves the right to modify this information without prior notification and does not make a warranty or representation of any kind, whether implied or expressed with respect to the information contained herein. Draka Cableteq assumes no risks, and will not be liable for direct or indirect, special; incidental or consequential damages, any defect or personal injury resulting from the use of this document. --PRYSMIAN Draka Engineered Solutions One Tamaqua Blvd �.� Draka Schuylkill Haven PA 17972 Phone:570-385-4381 Fax:570-385-1092 Project Name: I Generac Part Number: I 382891 Quote Number: NA File Number: type tc thhn-pvc 3C3 1 C8 6C18 382891 GENERAC Page Number: Page 1 of 2 EngDrawing-RevOl-Apd107 Physical Characteristics Conductor Color Code: 3 AWG - Black, White and Red 8 AWG - Green 18 AWG - Black, Red, Yellow, Yellow/Black, Blue and White Jacket Color: Orange Electrical / Optical Characteristics Voltage: 600V Specifications Conductors: ASTM B 3, ASTM B 8, ASTM B174 Insulation: ICEA S-95-658 (NEMA WC 70), ICEA S-73-532 (NEMA WC 57), UL 83 for Type THWN wires Jacket: ICEA S-95-658 (NEMA WC 70), ICEA S-73-532 (NEMA WC 57), UL 1277 Ratings UL THWN 600V UL Type TC-ER-JP 600V The insulation is acceptable for use in locations at 75 °C dry and 75 °C wet. The cable is suitable for use in cable trays, aerial or direct burial installations. Packaging Bulk reels R e DATE CHANGE DETAIL v �0RPPYSMIAN Draka Engineered Solutions 0 02/03/17 New Issue One Tamaqua Blvd 1 �..> Draka Schuylkill Haven PA 17972 Phone:570-385-4381 Fax:570-385-1092 2 3 Approvals: Engineering: Final: Project Name: Generac Draka Cableteq USA Inc. reserves the right to modify this information without prior Part Number: 382891 notification and does not make a warranty or representation of any kind, whether implied or expressed with respect to the information contained herein. Draka Cabletaq assumes no risks, and will not be liable for direct or indirect, special; incidental or consequential damages, Quote Number: NA any defect or personal injury resulting from the use of this document. type tc thhn-pvC 3C3 1 C8 6C18 382891 EngDrawing-Rev01-Apri107 File Number: GENERAC Page Number: Page 2 of 2 ENERACO 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features Model 0007039-1, 0007039-3 (20 kW) • Intelligently manages up to four air conditioner loads with no additional ardware. G007043.2, G007043-3 (22 kW) No. of poles 2 • Up to eight additional large (240 VAC) loads can be managed when d in conjunction Current rating (amps) 200 ith Smart Management Modules (SMMS). Voltage rating (VAC) 120/240,10 • Electrically operate , mec - c s or fast, clean connections. Utility voltage monitor (fixed)* • Rated for all classes of load,100% equipment rated, both inductive and resistive. -Pick-up -Dropout 80% 65% • 2-pole, 250 VAC contactors. Return to Utility` Approx 13 sec • Service equipment rated, dual coil design. Exercises bi-weekly for 5 minutes' Standard • Rated for both aluminum and copper conductors. ETL or UL listed Standard NEMA/UL 3 • Main contacts are silver plated or silver alloy to resist welding and sticking. 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility.(EEEEo 250 MCM - #s *Function er Dimensions Exercise can be set to weekly, bi-weekly, or monthly 200 Amps 120/240, 10 Open Transition Service Rated Height Width Hi H2 W1 W2Depth in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 PWRview Automatic Transfer Switch Features • Integrated PWRview monitor provides real-time energy usage data through PWRview app. • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Heavy duty Generac Contactor is an ETL recognized device. Dimensions 200 Amps 120/240,1a Open Transition Service Rated Height width Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 1 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 I—w, 17 t_ rp H1 L L DEPTH yn Model G007210.0 (24 kW) No. of poles 2 Current rating (amps) 200 Voltage rating (VAC) 120/240,10 Utility voltage monitor (fixed)* -Pick-up 80% -Dropout 65% Return to Utility' Approx.13 sec Exercises bi-weekly for 5 minutes` Standard ETL or UL listed Standard Enclosure type NEMA 3R Circuit breaker protected 22,000 Lug range 250 MCM - #6 *Function of Evolution controller Exercise can be set to weekly, bi-weekly, or monthly