HomeMy WebLinkAboutTrussTypical Cornerset Specifications LEDGER CONNECTIONS BY BUILDER. o Y (UNLESS NOTED OTHERWISE) *PLEASE, VERIFY* *SOME ROOF PLANES VARY FROM ELEVATIONS* *ROOF LOADING BREAKDOWN IS NOT SPECIFIED IN PLANS (TCLL, TCDL, BCLL BCDL). APPROVAL OF THIS LAYOUT IS ACCEPTANCE OF THE LOADING BREAKDOWN SHOWN ON THE ENGINEERING SHEETS AND THIS LAYOUT* *VERIFYALL BEARING HEIGHTS* '4" J1 A Z Z Z Z J3 A J5 J5 E01G E02 E03 10' CLG. Q E04 'J N Q n Q n Q n Q n n n n n n Q E04 N z o N o J1A 1 ::N-, Z y✓i,9 �` > E04 > ��'�0 J3. o J3 2. a > E04 18�. J5 o o J5 A18G " > > o A17G _._...__._ A15 a YLIGHT a c 1O' LG. iv t_ A16 3'10"8 A14Ga Ar A13 Al2 A11 — _ AIO V A0B A08 N PB03 A08 N 10' CLG. PB02 A08 N PB01 N A05 A04 08 :;Z! IV it NZbM dA02 M a B04 C B04 a 16'8' 12 o K 0 12 - 604 D03 B K 10' CLG. B04 10' CLG. D03 B 1 D02 B03 J5C DBL. LGR. BTM. a 1a iv DBL. LGR. J5c ,� �, ✓� D02 BTM. @ 1B' S� n B03 J3 N J3 in 14, Cil G. DOIG z z B03 A J7 z z J2A N B02 J2A 1'S". �S �pP 99 v, B02 �gP ✓� ✓ a JI HAtCH LEGEND B02 B02 V B6z �4'5 ---------- 8'64'5"� 7T8" N B02 B02 B02 m m N B02 N B02 10' CLG. 502 N B02 V eoz I V B01G ze J4 J4 ' J3 t0 J3 0 � J2 s J2 � y✓� A Z HBB b 2t ZI Z BB Z A Z Z JIB m J18 ci 14'8"— _5�` Attach End Jacks w/ (4) 0.131"0 ToeNails @ T & (3) 0.131"0 ToeNails @ B I�G I'm* NOTE: ALL CEILING DROPS BELOW BEAM ARE L y a E > w �.O cN.N.a Oo Attach Corner Jacks w/(2) BY BUILDER. (UNLESS NOTED OTHERWISE) 2 � 5 0 o 2 N 131"0 ToeNails C>. TC: & BC a y t 4 � (tYP) * NOTE: THIS TRUSS PLACEMENT DIAGRAM IS TO SHOW a E o 2 N TRUSS I D AND TRUSS LOCATION ONLY THE BUILDING = OD r � T� E �- m " DESIGNER IS RESPONSIBLE FOR THE STRUCTURAL STABILITY OF THE ENTIRE STRUCTURE. REFER TO THE NL V1. U y.t. = a O co y `- INDIVIDUALTRUSS ENGINEERING DRAWINGS FOR F2 0 C 8C'E o o 2 > GRAVITYAND UPLIFT LOADS. 8 y a c o m FOR BRACING & ERECTION DETAILS REFER TO BCSI-03 Q N� O. 0 N � .�gt o 6 w o AND/OR ENGINEER OF RECORD. R « a °� a;� 10 L °1 0 2 o a Ol +A C O W C C REPRESENTS THE LEFT SIDE N w C O V o ® OF EACH TRUSS DRAWING ¢ 2 � y ° a,m m Typ. Corner Jack Placement-- 1' 10-15/16" 210" 2'0" 11-1/16" ( NOTE: REFER TO SIMPSON CONNECTOR8 2- F E m CATALOG FOR INSTALLATION DETAILS) 2 A LUS24 H HHUS46 Q --- m' E B LUS26 J THA422 R--- o o E m ❑ E 0 U 0 C HUS26 K MUS26 S - - - y 9 „i2 C.~ p HUS28 L THJA26 T--- 3 B v E y t °OF E HHUS26-2 M HGUS28-2 U - - - v ° _ " $ aE.m rn 2 m-� m F HHUS282 N --- V --- o �om0.o�` O W O i M O O G LUS46 P --- X --- ,OI, 12- ,=-Em _ CD ° , z `o ~ 5 HBB HANGER BY BUILDER BBB BEAM BY BUILDER ZE m 2 o y o p w u, c . a ` Z LSTA12 @ TC & BC * NOTE: LSTA STRAP v Lu m `m a rn m INDICATED TO BE USED IN ❑ 00 m o t6 m s Zt LSTA12 @ TC CONCORDANCE WITH a` c 0 c d .- m w a o m Zb LSTA12 @ BC CORNERSET DETAIL. o a °mow N 20 O LOADING ROOF FLOOR WIND LOAD tm. �F-� 0 0 02 t E m � o a, wc DuNo o — LIVE LOAD 30 ASCE «$ n OO ` 0am C, C C 8 m N L O m~ U DEAD LOAD 15 170 C _ am,a w _O ._ C N O 0 '� N 00. Ui >_ 00 LIVE LOAD CAT 11 m 0= C O 0 = u W W 2 � a) em 1p�Of am Ov DEAD LOAD 10 ENCLOSED 67 mK.O cv3a oz o TOTAL LOAD 55 FBC 2017 RES o U N �' 1 E E 2 c 2 ❑ 0 N O CM N t0 ,F y z° DURATION FACTOR 1.25 TPI 2014 U N 0 my d 1n REV DATE BY REMARKS a 2 t N= 2 N O SE 4 E2 w E 2= 2 '• - - O N= -ti O 8 t N W i 0 « ] N o - O - --/--/---- - c r U N N U iJ " `° C E.O U AUG 1 9 gnn _ c 1 o o m o -/ -/ LST, Luoe County ge+mttttmg m E i x 3 D O o It is understood that above []APPROVED o m w 2 conditions have been reviewed & o m ❑ r w are acceptable for the fabrication ❑ APPROVED AS NOTED d' m m'3 0 at trusses, elevations, pitches, C 0 •- 0 U �, 0 0 y N r .. _ ° E overhangs, fascias,ceiling ❑ REVISE AND RESUBMIT m cc w a E d m elevations/pitches, bearing y W= o= 0 0 0= s 2 A « `E = E 0. conditions &all detail pertaining ❑ REJECTED C 6 on 'S .°1c o 'v m � n „ to this truss placement plan. No � ja N �, s y a o � - back charges will be accepted 0 o 2, a. m m o without previous written approval DATE N N C ._ h w� a) g N H from an A-1 Roof Trusses E tu: O _ O representative. REVIEWED BY 8�)2 ��m m =00� O E 0. ='- o PLAN DATE ARCH: /--/---- STRUCT: /--/---- '5 2 0 m ; o m d m d E a r= c Y �vcism�a3i>o.Ur` CUSTOMER JOHN & CHERRIE 2 -a =t o t 2 m� w w m o = w.n O C 0 ` O N 0 p O N � m E a m JOB NAME PALOMINO RESIDENCE 0 5:5 9�- a d �o 8�yrnm d U N m 0 2 «.2� C C L iU 0 O OPTION(S) t up m 0 y m 0 a -a N U H C 2 C i; m'O 0 L C „ W 0 _ C Imo L 0 O am :0 012 ors c 0 y 3 c COMMUNITY c z 0 m.y N - �. N me 5,5 0p / LOT# c 0 0 0p o uy 0 CITY - =oo °i DS .03 0 v1O COUNTY 0 off:oU v� a0i 'y a y r� 0a, � m 0 C = BLDG. BLDG a o3 o a = 3 - - _c'o aE 0 y m'9 m❑'o 0 11pDigitally signed by TYPE # E gw wa o� N G C N pdt 3C Nam. Mai i LA�t 1,�.81�i:Fik, c �.8.� w~ d m o m. �/l a li t l e l JOB # 81433 MASTER - m@ a o 0- 0 9 a= c u > Q c 4c soya• •x.•w •Oi. �Y�.� ❑ H L O = 0 to "= e * DRAWN SCALE ~CLj t y w ^� ;± N{ 04 $ ... DATE o a 0-6 u c 0 = 12.20-04�00� � '" 7/31/20 p v g '� c am m c Z T� f0 U N 17 V5 ID • BS NTS 2a o�2m�oom .� Ail �r t ,~. '+„.n,fi t a'• °'16' 'ka F..E a. 3 -No v u, py �,\ s -•- , 3/4" = 1' ., 1 ROOFw °' 0 E , u � O a c m ti 5 RIAI # U m '� J= 0 M 2 2 SEF6 AS FB3 1812 BC781D 52 B44E ACES CA � g y 2«3 4 N = O c 3 F - A FLORIDA CORPORATION � 0 c " Bpi � W� j, `0 Ph 772-409-1010 / Fax 772-409-1015 = c4� 5 a hftp://www.a1truss.com m C 0_ 2 T°= 0 8 p W=W au1 ._ 0 N r I. A4 ROOF &*MTRUSSES A FLORIDACORPORATION RE: Job 81433 Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. Site Information: A U G 19 "020 Customer Info: JOHN MU -5$.q_dc&WuQYJEARi Lot/Block: Address: PSL, FL Subdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC 2017 RES / TPI 2014 Design Program: Alpine Engineered Products Wind Code: ASCE 7-10 Wind Speed: 170 Roof Load: 55.0 psf Floor Load: 0.0 psf This package includes 70 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. A-1 Roof Trusses 4451 St Lucie Blvd 'Fort Pierce, FL 34946 ND Project Name: PALOMINO RESIDENCE No. Seq # Truss Name Date No. Seq # Truss Name Date No. Seq # Truss Name Date 1 7578 A01 G 8/4/20 13 4294 A13 8/4/20 25 4053 CO3 8/4/20 2 4089 A02 8/4/20 14 4300 A14G 8/4/20 26 4194 C04 8/4/20 3 4267 A03 8/4/20 15 3958 A15 8/4/20 27 4252 D01 G 8/4/20 4 4270 A04 8/4/20 16 4303 A16 8/4/20 28 4029 D02 8/4/20 5 4273 A05 8/4/20 17 4237 A17G 8/4/20 29 4032 D03 8/4/20 6 4276 A06 8/4/20 18 6762 A18G 8/4/20 30 6756 E01 G 8/4/20 7 4279 A07 8/4/20 19 7572 B01 G 8/4/20 31 3923 E02 8/4/20 8 4285 A08 8/4/20 20 14085 B02 8/4/20 32 3926 E03 8/4/20 9 4288 A09 8/4/20 21 14062 B03 8/4/20 33 4190 E04 8/4/20 10 3987 A10 8/4/20 22 4065 B04 8/4/20 34 6771 G01 8/4/20 11 3984 A11 8/4/20 23 6768 C01 G 8/4/20 35 7575 G02 8/4/20 12 13981 1 Al2 8/4/20 24 4050 1 CO2 8/4/20 36 3964 G03 8/4/20 i is u uaa w awu iy,a) roic� c� n.w .,.v. —,. N,.N-- uy—p.l rc � nju ¢xrw nwucu, B ru. unuer n ryuBcaibupervisron Udbeu on me pdrdmeterb prowaea oyH--r MOOT i russes, t ta. Truss Design Engineer's Name: Manuel Martinez My license renewal date for the state of Florida is February 28,2021. NOTE:The seal on these drawings indicate acceptance of professional engineering responsibility solelyforthe truss components shown. The suitability and use of components forany particular building is the responsibTrty of the building designer, perMSUTPI-1 See.2. The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction documents (also referred to at t'urres as'Structurdl Engineering Documents) provided bythe Building Designer indicating the nature and characterofthe work The design criteria therein have been transferred to Manuel Martinez PE by [Al Roof Trusses orspecific location]. These TDDs (also referred to attinres as'Structural Delegated' Engineering Documents) are specialty structural component designs and maybe part of the projects deferred or phased submittals. Asa Truss Design Engmeer(i.e, Speciatty Engineer), the seal hen: and on the TDD represents an acceptance of professional engineering responsibility forthe design of the single Truss depicted on the TDD only. The Building Designer is responsible forand shall coordinate and review the TDDs for compatibility with theirwritten engineering requirements. Please review all TDDs and all related notes. N1 Manuel MartinE .sg$ lAt. e _ SE F6 AS F03 1 129C?8 Dt�SE Ffd CEAC6 CA - t� Manuel Martinez, RE 4620 Parkview Dr. SLCloud,FL34771 = .,y Page 1 of 2 A4 ROOF TRUSSES: A FLORIDA CORPORATION RE: Job 81433 Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. No. Seq # Truss Name Date No. Seq # Truss Name Date 37 4234 G04 8/4/20 75 STDL05 STD. DETAIL 8/4/20 38 4166 HJ3 8/4/20 76 STDL06 STD. DETAIL 8/4/20 39 4023 HJ5 8/4/20 77 STDL07 STD. DETAIL 8/4/20 40 7569 HJ6 8/4/20 78 STDL08 STD. DETAIL 8/4/20 41 6765 HJ7 8/4/20 79 STDL09 STD. DETAIL 8/4/20 42 6753 HRA 8/4/20 80 STDL10 STD. DETAIL 8/4/20 43 6759 HJ7B 8/4/20 81 STDL11 STD. DETAIL 8/4/20 44 4017 HJ8 8/4120 82 STDL12 STD. DETAIL 8/4/20 45 3908 11 8/4/20 83 STDL13 STD. DETAIL 814/20 46 3949 JIA 8/4/20 84 STDL14 STD. DETAIL 8/4/20 47 4306 JIB 8/4/20 85 STDL15 STD. DETAIL 8/4/20 48 14160 J2 8/4/20 86 STDL16 STD. DETAIL 8/4/20 49 4020 J2A 8/4/20 50 3911 J3 814/20 51 4008 J3A 8/4/20 52 4315 J313 8/4/20 53 14157 J4 8/4/20 54 4011 J4A 8/4/20 55 4342 J4G 8/4/20 56 6750 J5 8/4/20 57 4014 J5A 8/4/20 58 14320 J513 8/4/20 59 6744 J5C 8/4/20 60 4005 J6A 8/4/20 61 4035 J7 8/4/20 62 3905 RA 8/4/20 63 14323 J713 8/4/20 64 4112 PB01 8/4/20 65 4115 PB02 8/4/20 66 4109 PB03 .8/4/20 67 4336 VM02 8/4/20 68 14337 `•VM04 814/20 69 4338 VM06' 814/20 70 4339 VM07 8/4/20 71 STDL01 STD. DETAIL 8/4/20 72 STDL02 STD. DETAIL 8/4/20 73 STDL03 STD. DETAIL 8/4/20 74 1 STDL04 STD. DETAIL 8/4/20 Page 2 of 2 Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job 81433 Truss Truss Type lyty P A01 G I MONO I Q1 2 08/04/2020 7578 l� �- 127 7'0"13 8'11 "3 i- 811 "3 10'0"13 1 2+ 14'4" 11110X14(R) 1111.5X4 1113X4 IIIH0714(R) 12 \\\4X4(R) EaH1319 5 p D E F =3X10(C6) 5X6(C6)r_--5X14 C (a B AD' AC AB AA Z Y X W =3X10 =7X10 =1-10710 =10X10 =1-11319(I) 1115X12(R) SEAT PLATE REQ. 2 59W 63'8" r 1810"5 1876 5176# 6269t Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 6.37 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Lumber Top chord 2x8 SP 2400f-1.8E T5 2x4 SP #2; Bot chord 2x8 SP 2400f-1.8E Webs 2x4 SP #3 W4,W6,W8,W1 0,W14,W1 6 2x4 SP #2; W11,W13 2x4 SP M-30; W12 2x6 SP #2; Lt Slider: 2x8 SP 2400f-1.8E; block length = 2.900' Rt Slider: 2x8 SP 2400f-1.8E; block length = 2.900' Bracing (a) Continuous lateral restraint equally spaced on member. Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @ 7.75" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. (1) 112" bolts may be used for (2) 0.131"x3", min. nails on The Bottom Chord Only. Special Loads --(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 78 plf at 0.00 to 78 plf at 63.67 =4X6 =7X8 III H0710(R) =5X6 K ML N p '--4X4 ^15X4 P (a) V U T S =7X8 =H0710 =7X10 =4X6 Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.859 J 825 360 ktRT(CL): 1.655 J 428 354 HORZ(LL): 0.184 S - - HORZ(TL): 0.354 S - - Creep Factor: 2.0 Max TC CSI: 0.760 Max BC CSI: 0.988 Max Web CSI: 0.989 Wgt: 1185.8 Ibs VIEW Ver. 20.01.01A.0724.11 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 12.17 19.24 TC 24 37.10 51.31 BC 61 0.00 63.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 26'2"5 Z-�5X12 T =3X8(C6) /yC6) R rO AE SEAT PLATE REQ. ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL AD 9434 /- /- /- /5153 /- AE 8343 /- /- /- /4525 /- Wind reactions based on MWFRS AD Brg Width = 8.0 Min Req = 3.9 AE Brg Width = 8.0 Min Req = 3.5 Bearings AD & AE are a rigid surface. Bearings AD & AE require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords ITens. Comp. A - B 222 -480 J - K 8864 -16022 B - C 4152 -7572 K - L 6608 -12031 C - D 5097 - 9251 L - M 6529 -11913 D - E 4750 - 8634 L - N 97 -140 E - F 7415-13407 M - O 3923 -7204 F - G 6248-11347 N - O 94 -137 G - H 6223-11302 O - P 4379 - 7999 H -1 6733-12219 P - Q 3624 - 6653 1-1 6758-12265 Q - R 182 -411 Loading Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Truss passed check for 20 psf additional bottom chord live load !it dioatswith 42"-high x 24"-wide clearance. AD -AC 4993 -2749 X - W 16011 -8857 A -AD 429 -186 W - V 14179 - 7836 Wind AC -AB 7021 -3848 V-U 9781 -5377 Wind loads and reactions based on MWFRS. AB -AA 11069 -6117 U - T 9781 -5377 AA- Z 11069 - 6117 T - S 6162 - 3354 Blocking Apply additional nailing over the following bearings with fasteners at 4" oc both perpendicular and parallel to grain. In lieu of additional nailing, apply blocking reinforcement to prevent buckling of members over the bearings: Bearing 1 located at 2.0' (blocking >= 5.50" if used) Bearing 2 located at 61.0' (blocking >= 5.50" if used) BC: From 20 plf at 0.00 to 20 plf at 26.14 BC: From 50 plf at 26.14 to 50 plf at 30.19 Additional Notes BC: From 20 plf at 30.19 to 20 plf at 63.67 BC: 5176 lb Conc. Load at 18.86 WARNING: Furnish a copy of this DWG to the installation contr BC: 6269 lb Conc. Load at 37.47 follow provisions of BCSI in handling and installation of trusses injuries. Do not permit inexperienced and uninstructed people to Plating Notes "WARNING" note below. BCSI recommends retaining a register engineer for the design of temporary bracing. All plates are 7X10(R) except as noted. The maximum concentrated load is 6270# (1) - plates so marked were sized using 0% Fabrication Tolerance, 10 degrees Rotational Tolerance, and/or zero Positioning Tolerance. Z - Y 13481 -7455 S -AE 4398 -2406 Y - X 8959 - 4936 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. -Webs Tens. Comp. AD- B 3381 - 6086 X - I 75 -170 B--AC 2181 -1178 X - J 3799 - 6788 AC- C 936 -1621 J - W 352 - 341 C -AB " ` 1826 -1017 W - K 3353 -1869 IIAAEFailuM iq K - V 2168 - 3796 .-1681 c,Rg result I�fIg1024 V - M 3975 -2174 S( o1 t SR30 M - T 2427 -4342 -13101 O - T 3034 -1632 F - Y ,: 2431 -4317 T - P 1425 -788 G - Y 78 -168 P - S 796 -1376 Y - H 3700 -2016 S - Q 1899 -1017 H - X 5679 -3114 Q -AE 2977 -5384 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (rDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerinE Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvriaht 0 2016 A-1 Rnnf Tnr. caa - Renroduclinn of thin d-mnnt. in anv fmm�. in nmhihhed withmit thn writtan mmiecion of A-1 Rnnf Tntecxx. JOD 81433 I fuss A02 I russ I ype COMN 1474 i 7'0"13 i 610"15 i 6'10"15 12 1111.5X4 5 p 06X8 C =4X6(:>.B,1- 555 Aa) Z" Ury I-ly Ut5/U4/'LULU 1 1 aoss I i 14'4"13 1474 �{ =8X8 F 1117X10(R) =3X4 D E G H W' V U T S R Q 1114X10 ==-8X10 =H0510 =5X6 =H0510 =-3X6 SEA, PLATE REQ. 2 59'8" i 63'8" Loading Criteria (ps0 Wind Criteria Code / Misc Criteria TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 15.00 Speed: 170 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: 25.00 ft WAVE, HS NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 6.37 ft Loc. from endwall: not in 17.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 Bot chord 2x6 SP 2400f-2.0E Webs 2x4 SP #3 W1 2x6 SP #2; W2,W8, W9 2x4 SP #2; Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 7X8 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 14.19 21.26 TC 24 35.08 49.48 BC 90 0.00 63.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24%wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. Defl/CSI Criteria PP Deflection in loc VERT(LL): 0.616 G VERT(CL): 1.157 G HORZ(LL): 0.138 D HORZ(TL): 0.260 D Creep Factor: 2.0 Max TC CSI: 0.904 Max SC CSI: 0.993 Max Web CSI: 0.982 Wgt: 442.4 Ibs VIEW Ver. 19.01.00A P O =5X6 =1­10510 I III1.5X4 J -6XB (a)=4X6(A1) K a L N IP =8X10 1114X10 SEAT PLATE REQ. ♦ Maximum Reactions (Ibs) L/# I Gravity Non -Gravity zan Loc R+ / R- / Rh / Rw / U / RL 1 354 W 3584 /- /- /1995 /834 1406 - M 3584 /- /- /1995 /865 !- Wind reactions based on MWFRS W Brg Width = 8.0 Min Req = 3.0 M Brg Width = 8.0 Min Req = 3.0 Bearings W & M are a rigid surface. Bearings W & M require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. 8.15 A - B 272 -440 G - H 5026 -7860 B - C 3264 -5450 H -1 4440 -7023 C - D 3463 -5401 I - J 3390 -5401 D - E 4474 - 6934 J - K 3188 - 5447 E- F 3865 -59, 7 K- L 269 -442 F - G 3860 - 59. 7 I Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - W 443 - 248 R - Q 7890 -4567 W - V 818 -492 Q - P 7088 -4002 V - U 5132 -2971 P - O 5131 -2891 U - T 5132 -2971 O - N 5131 -2891 T - S 7001 -4036 N - M 819 -470 S - R 7890 -4567 M - L 444 -245 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. W - B 2135 - 3370 G - Q 599 - 635 B - V 4250 - 2410 Q - H 1048 - 757 C - V 482 -445 H - P 1039 -1386 V - D 303 - 363 P -1 2512 -1454 D - T 2435 -1485 I - N 298 - 364 T - E 1107 -1418 N - J 494 -451 E - S 1464 - 2135 N - K 4247 - 2348 F - S 3771 -2306 K - M 2090 -3365 S - G 2166 -3324 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn,c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted an the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the .St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. (`.nnvriaht 0 2016 A-1 Rnof Tnisses - Rsnrnduotion of this d-iment. in anv form. is nmhihitad without the written nnnnission of A-1 Roof Tni. sss. Job 814.33 Truss Truss Type Qty Ply A03 MONO 1 1 08/04/2020 4267 i 1674 7'0"13 - + 4'10"15 --}-- 4'10"15 1 14'4"13 1674 =7X8 %7X6(R) 1117X8(R) G =8X8 1113X4 =4: Al) r A vv v u t a M U r U 1114X10 =7X8 =6X6=4X8 =H0510 =7X8 =H0510 =H0510 =8X10 1114X10 SEP T PLATE REQ. SEAT PLAT REQ. 59'8" Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 15.00 Speed: 170 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: 25.00 ft WAVE, HS NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 6.37 ft Loc. from endwall: not in 17.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 Bot chord 2x6 SP 2400f-2.OE B1 2x6 SP #2; Webs 2x4 SP #3 W1 2x6 SP #2; W2,W8, W12 2x4 SP #2; Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 6X8 except as noted. Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in cc) Start(ft) End(ft) TC 24 16.19 23.26 TC 24 33.08 47.48 BC 79 0.00 63.67 Apply pudins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42'-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes WARNING: Fumish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. 63'8" Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc Udefl L/# Gravity Non -Gravity VERT(LL): 0.543 H 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 1.019 H 694 354 Y 3584 /- /- /2012 /853 /406 HORZ(LL): 0.129 E - - O 3584 /- !- /2012 /845 /- HORZ(TL): 0.244 E - - Wind reactions based on MWFRS Creep Factor: 2.0 Y Brg Width = 8.0 Min Req = 4.2 Max TC CSI: 0.781 O Brg Width = 8.0 Min Req = 3.0 Max BC CSI: 0.997 Bearings Y & O are a rigid surface. Max Web CSI: 0.967 Bearings Y & O require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:446.6lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ven 19.01.00A.0618.15 A - B 184 -386 H -1 4126 -6530 B - C 3210 -5412 I - J 4126 -6530 C - D 3500 - 5688 J - K 3553 - 5590 D - E 3514 - 5538 K - L 3539 - 5673 E - F 3402 - 5163 L - M 3315 - 5747 F - G 3795 - 5912 M - N 368 - 668 G - H 3796 - 5914 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - Y 388 -164 T - S 7002 - 3960 Y - X 762 -468 S - R 7002 -3960 X - W 4931 -2829 R - Q 5047 -2764 W - V 4931 -2829 Q - P 5047 -2764 V - U 6414 - 3634 P - O 1056 - 587 U - T 6414 - 3634 O - N 685 - 362 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp Y - B 2141 -3358 T - H 1900 -2787 B - X 4283 -2455 H - R 569 -664 X - C 604 - 813 I - R 555 - 703 C - V 332 -124 R - J 2067 -1197 E - V 1396 - 750 J - P 332 - 252 V - F 1236 -1780 P - L 586 - 577 F - T 1335 -1765 P - M 4224 -2289 G - T 3945 -2433 M - O 2110 -3332 'WARNING"" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineehn,c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 0471$2 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkVIBW Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrinht 0 2016 A-1 Rrmf Tntaca - Ranrodlidinn of this clot , nt. in anv farm. is nrohihitad without tha written nnrmiF inn of A-1 Rmf Tni s . .roo r ru55 I cuss type ury fry Ub/U4/ZUZU 4270 81433 A04 MONO 1 1 �- 1874 "13 2'10"15 '10"15 -�{^ -�- --� TO"I 1874 1117X8(R) =7X8 1117X8(R) N7X8(R) =3X6 =6X8 G T 11125X6 E F H I J 112X4 12 5 � T CD KL In �5X8 a (a) ((a (a) (a) (a a \5X b) =4X6(A1) zo (a 4X6(A1) B M A a) N 8' Y X W V U T S R Q P 0 1114X10 =7X10 =7X8 =8X8 =4X6 =7X10 1114X10 SE�j PLATE REQ. SEAT PLAT REQ. 59'8" 63'8- Loading Criteria (psf) Wind Criteria Code / Misc Criteria Deft/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udefl L/# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(LL): 0.536 H 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 1.006 H 703 354 Y 3584 /- /- /2029 /872 /406 BCDL: 10.00 Risk Category: 11 FT/RT:10(0)/10(10) HORZ(LL): 0.113 E 0 3584 /- /- /2029 /826 P EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.213E - Wind reactions based on MWFRS Des Ld: 55.00 Mean Height: 25.00 ft WAVE, HS � Creep Factor: 2.0 Y Brg Width = 8.0 Min Req = 3.0 NCBCLL: 10.00 TCDL: 5.0 sf p Max TICCSI: 0.891 1 O Brg Width = 8.0 Min Req = 3.0 Load Duration: 1.25 BCDL: 5.0 psf " Bearings Y & 0 are a rigid Max BC CSI: 0.984 surface. Spacing: 24.0 MWFRS Parallel Dist: h to 2h Bearings Y & 0 require a seat plate. C&C Dist a: 6.37 ft Max Web CSI: 0.965 I Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 17.00 ft Wgt: 463.4 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver. 19.01.00&06�18.15 A - B 464 -875 H - I 3935 -6239 Lumber B - C 3330 -5863 I - J 3772 -6030 C - D 3574 -5770 J - K 3558 -5758 Top chord 2x6 SP #2 D - E 3596 -5747 K - L 3537 -5780 Bot chord 2x6 SP 2400f-2.0E Webs 2x4 SP #3 W1 2x6 SP #2; W2,W8 2x4 SP #2; E - F 3765 -5966 L - M 3284 -5865 F - G 4150 - 6511 M - N 457 - 872 Bracing i G - H 4333 -6803 (a) Continuous lateral restraint equally spaced on member. Maximum Bot Chord Forces Per Ply (Ibs) Plating Notes Chords Tens.Comp. Chords Tens. Comp. All plates are H0510 except as noted. I A - Y 907 -476 T - S 6065 -3197 Purlins Y - X 1277 -699 S - R 6065 -3197 X - W 4939 -2650 R - Q 4927 - 2590 In lieu of structural panels or rigid ceiling use purlins W - V 4939 -2650 Q - P 4927 -2590 to laterally brace chords as follows: V - U 4939 -2650 P - 0 1273 - 690 Chord Spacing(in oc) Start(ft) End(ft) U - T 5383 -2784 O - N 904 -469 TIC 24 18.19 25.26 TC 24 31.08 45.48 BC 100 0.00 63.67 Maximum Web Forces Per Ply (Ibs) Apply purlins to any chords above or below fillers Webs Tens.Comp. Webs Tens. Comp. at 24" OC unless shown otherwise above. Y - B 2129 -3312 H - T 1947 -2848 Loading B - X 4072 -2153 T -1 275 -264 Truss passed check for 20 psf additional bottom chord live load in areas with C - X 653 - 684 1 - R 790 - 954 42"-high x 24"-wide clearance. X - E 531 -327 R - J 1699 - 941 E - U 1603 - 913 J - P 540 - 326 Wind U - F 1882 -2760 P - L 677 - 706 Wind loads based on MWFRS with additional C&C member design. U - G 1987 -1284 P - M 4079 -2121 G - T 2827 -1832 M - 0 2104 - 3310 Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. I I "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out inithe TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C flaht 0) 2016 A-1 Reef Tnz - Renrvturlinn of this dnnrment. In anv torn. Is nmhihtted withnut the written merrissinn of A-1 Rn"f Tn3s ea. Job 81433 Truss Truss Type A05 MONO Qty Ply 108/04/2020 1 1 4273 T M O iT 1� z0'z" =4 =7X8 =7X8 �SXR E F 23715 1207 III3X4 =7X8 G H _ ova 'Al) •.• . V t- V Iv M =6X6 =3X4 =7X8 =3X4 =3X6 =7X8 =4X8 =6X6 -7X8 SEAT PLATE REQ. SEAT PLATE REQ. f 2 A 59W 12 Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 15.00 Speed: 170 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 6.37 ft Loc. from endwall: not in 17.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 Bot chord 2x6 SP 2400f-2.0E Webs 2x4 SP #3 W1 2x6 SP #2; W2, W8 2x4 SP 2400f-2.0E; Lt Splice Block: 2x4 SP #3; Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 20.17 43.50 BC 107 0.00 63.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. 63'8" Defi/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.371 G 999 360 Loc R+ ! R- / Rh / Rw / U / RL VERT(CL): 0.696 G 999 351 V 3582 /- /- /2051 /864 /390 HORZ(LL): 0.113 M - - M 3582 /- /- /2051 /864 /- HORZ(TL): 0.213 M - - Wind reactions based on MWFRS Creep Factor: 2.0 V Brg Width = 8.0 Min Req = 3.0 Max TC CSI: 0.766 M Brg Width = 8.0 Min Req = 3.0 Max BC CSI: 0.976 Bearings V & M are a rigid surface. Max Web CSI: 0.971 Bearings V & M require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:435.4lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 A - B 287 -760 G - H 3247 -5529 B - C 391 -816 H - I 3063 -5443 C - D 3032 - 5503 I - J 3033 - 5506 D - E 3061 - 5441 J - K 390 - 813 E - F 3239 - 5512 K - L 286 - 757 F - G 3247 -5528 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - U 783 -300 Q - P 5535 -2593 U - T 5035 -2565 P - O 4719 -2256 T - S 4719 -2254 O - N 4719 -2256 S - R 4719 - 2254 N - M 5038 - 2567 R - Q 5535 -2593 M - L 780 -298 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B - U 752 - 746 G - P 547 - 682 U - C 2765 - 5199 P - H 1259 - 631 C - T 376 -197 H - N 493 -171 T - E 489 -171 N - J 377 -197 E - R 1260 - 621 J - M 2768 - 5205 R - F 554 - 687 M - K 751 - 746 F - P 190 -190 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unlessotherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerinE Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkVieW Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the .St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI.1. ('.onwiaht A 2016 A-1 Ronf Tmcses— Renmdurdinn of this dorerment. In anv form. is nmhihited vrithnut the written nannissinn of A-1 RoofTnrsses, Job 1 russ I russ I ype uty rry Ut3/U4/ZUZu 4276 81433 A06 MONO 1 1 22'2" *7X8 E 5 � T 12 g3X4C D o (a) a (a) SXSB 4X6(A1)A a) 19'3"15 1113X4=5X8 =7X8 F G Hi 7\>N���at.= 227 3X4 J--5X6 4X6(A1) s• 1114X10U 1114X10 X8=H0510= X4 =8X10 = X4=H0510 =6X8 SE�T PLATE RED. SEAT PLATE REQ. 2 59'8" ! fL 63'8" I Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defi/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(LL): 0.336 F 999 360 Loc R+ / R- ! Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.631 F 999 354 U 3577 /- /- /2060 /847 /429 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.094 M 1 - M 3583 /- /- /2060 /847 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.177 M - Wind reactions based on MWFRS Des Ld: 55.00 Mean Height: 25.00 ft WAVE, HS g Creep Factor: 2.0 U Brg Width = 8.0 Min Req = 3.0 NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0916 M Brg Width = 8.0 Min Req = 3.0 Load Duration: 1.25 BCDL: 5.0 psf " . Max BC CSI: 0.973 Bearings U & M are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h to 2h I Bearings U & M require a seat plate. C&C Dist a: 6.37 ft Max Web CSI: 0.885 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 17.00 ft Wgt: 428.4 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.15 A - B 309 -571 G - H 3123 -5250 Lumber B - C 2698 -5274 H -1 3010 -5410 C - D 2972 -5439 I - J 2972 -5447 Top chord 2x6 SP #2 T2 2x6 SP 2400f-2.OE; D - E 3010 -5402 J - K 2698 -5283 Bop chord 2x6 SP 2.0E E - F 3123 -52 K - L 309 -571 Webs 2x4 SP #3 W1 2x6 SP #2;,W2,W6 2x4 SP #2; F - G 3123 - 5249 Bracing (a) Continuous lateral restraint equally spaced on member. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Purlins A - U 590 -302 Q - P 4680 -2188 In lieu of structural panels or rigid ceiling use purlins U - T 962 -612 P - O 5224 -2629 to laterally brace chords as follows: T - S 5213 -2628 O - N 5224 -2629 Chord Spacing(in oc) Start(ft) End(ft) TC 24 22.17 41.50 S - R 5213 -2628 N - M 963 503 BC 107 0.00 63.67 R - Q 4677 -2187 M - L 589 - 302 Apply purlins to any chords above or below fillers at 24" CC unless shown otherwise above. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Loading Truss passed check for 20 psf additional bottom chord live load in areas with U - B 1959 -3350 Q - H 835 -422 42"-high x 24"-wide clearance. B - T 3913 -1813 H - P 653 -174 T - C 617 -890 P - J 473 -449 Wind C - R 473 -442 J - N 618 - 893 Wind loads based on MWFRS with additional C&C member design. R - E 649 -174 N - K 3922 -1813 E - Q 839 -422 K - M 1959 - 3354 Additional Notes j F - Q 645 -868 WARNING: Furnish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See ! "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER) ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineednE Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the Too only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, lace] building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkUeW Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. Convdnht 0 2016 A-1 Roof To— — Ranrnduntinn of this dnnrment. in am form. Is nmhihhad vAthart the written narmission of A-1 Roof Tnt. sas. Job Truss Truss Type Qty Ply 08/04/2020 r 81 433 A07 I MONO 11 1 4279 1=4X6(A1; r 24'2" 15'3"l5 247 c7X8 1112X4 =7X8 F G H SEAT PLATE REQ. =IAA =MUD IU=4A?j =HU/lu =4XC=HUblU =7X6 Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 6.37 ft Loc. from endwall: not in 17.0 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 T2 2x6 SP 2400f-2.0E; Bot chord 2x6 SP #2 B2,B3 2x6 SP 2400f-2.OE; Webs 2x4 SP #3 W1 2x6 SP #2; W2,W7 2x4 SP #2; Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 24.17 39.50 BC 78 0.00 63.67 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result in serious Injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. SEAT PLATE REQ. 59W 2' 63W - Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc Udefl L/# Gravity Non -Gravity VERT(LL): 0.333 G 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.625 G 999 354 V 3584 A A /2067 /825 /467 HORZ(LL): 0.099 N - - N 3584 A /- 12067 /825 A HORZ(TL): 0.187 N - - Wind reactions based on MWFRS Creep Factor: 2.0 V Brg Width = 8.0 Min Req = 4.2 Max TC CSI: 0.901 N Brg Width = 8.0 Min Req = 4.2 Max BC CSI: 0.981 Bearings V & N are a rigid surface. Max Web CSI: 0.992 Bearings V & N require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:455.0lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 A - B 201 -446 G - H 2913 -4812 B - C 2862 - 5623 H -1 3270 - 5480 C - D 2968 - 5543 I - J 2993 - 5429 D - E 2993 -5429 J - K 2968 -5543 E - F 3270 -5480 K - L 2862 -5623 F - G 2913 -4812 L - M 201 -446 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - V 451 -188 R - Q 4441 -2005 V - U 824 -559 Q - P 5107 -2483 U - T 5107 -2482 P - O 5107 -2483 T - S 5107 -2482 O - N 824 -390 S - R 4441 - 2004 N - M 451 -188 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp V - B 1969 - 3352 R - H 702 - 331 B - U 4392 -2119 H - Q 1153 -716 U - C 487 - 672 Q -1 681 - 717 C - S 323 - 271 Q - K 323 - 272 E - S 681 - 717 K - O 487 - 672 S - F 1153 -716 O - L 4392 -2119 F - R 702 -331 L - N 1969 -3352 G - R 576 - 740 'WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TOO, only Alpine connector plates shall be used for the TOD.to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TOO represents an acceptance of the professional engineedn.c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TOO only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TOO and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkVlew Dr guidelines of the Building Component Safety Information (SSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C nvrinht W 201R A-1 Ronf Tniecgc — Renrodurtinn of this donrment, in env In— is nmhihftnd without the written nemricsinn of A-1 Ronf Tnlsses. JOD 1 Russ 81433 A08 I russ I ype Uty my HIPS 1 3 1 1 Ub/U412UZU 4285 ti 1 2373 1615"10 _-7X8 =5X8 1112X4 F G H 12 1111.5X4 E 5 p 5X6D to 03X4C ()a (a) (a) (a) 65X10 B =4X6(A1 jA 1115X8 V U T S =5X8 =H0510 =5X8 =8X10 SEAT PLATE REQ. 224 A 59'8" - 63'8" - Loading Criteria (psf) Wind Criteria TOLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 6.37 ft Loc. from endwall: not in 17.0 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 Bot chord 2x6 SP 2400f-2.0E Webs 2x4 SP #3 W1 2x6 SP #2;` W2, W9 2x4 SP M-30; W7 2x4 SP #2; Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 23.60 40.07 BC 108 0.00 63.67 Apply puriins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes WARNING: Fumish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. Defl/CSI Criteria PP Deflection in loc VERT(LL): 0.400 H VERT(CL): 0.708 H HORZ(LL): 0.109 O HORZ(TL): 0.192 O Creep Factor: 2.0 Max TC CSI: 0.788 Max BC CSI: 0.970 Max Web CSI: 0.869 Wgt: 450.8 Ibs VIEW Ver. 19.01 237"3 J>(a) X6 S.. M�5X10 N=4X6(A1) =5X8 =H0510 =5X8 1115X80 SEAT PLATE REQ. ♦ Maximum Reactions (Ibs) Gravity Non -Gravity 360 Loc R+ / R- / Rh / Rw / U / RL 9 354 W 3911 /- /- /2066 /831 /456 - O 3911 !- /- /2066 /831 !- - Wind reactions based on MWFRS W Brg Width = 8.0 Min Req = 3.2 O Brg Width = 8.0 Min Req = 3.2 Bearings W & O are a rigid surface. Bearings W & O require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Camp. 8.15 A - B 257 -470 H - I 2976 -5564 B - C 2689 - 5931 I - J 3234 - 6067 C - D 2966 - 6157 J - K 29M - 6086 D - E 2994 -6086 K - L 2966 -6158 E - F 3234 - 6066 L - M 2688 - 5931 F - G 2976 - 5564 M L N 256 - 469 G - H 2975 - 5564 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - W 481 -247 S - R 5061 -2043 W - V 895 -610 R - Q 5760 -2557 V - U 5760 -2556 Q - P 5760 -2557 U - T 5760 -2556 P - O 895 -446 T - S 5061 -2042 O - N 481 -246 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. W - B 1950 - 3710 S - 1 800 - 380 B - V 4617 -1873 I - R 1244 - 669 V - C 588 - 905 R - J 596 - 579 C - T 367 - 342 R - L 367 - 342 E - T 596 - 578 L - P 589 - 906 T - F 1244 - 668 P - M 4617 -1873 F - S 800 -380 M - O 1949 -3710 H - S 629 - 811 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYERS) ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4620 ParkVieW Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer Is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. r-daht (5) 2016 A-1 Ronf Tnicsas - Rnnmrindinn of this domrmnnt. in anv form. is nrnhihite.A withmn the wrimnn narmi. sim of A-1 Rod Tniacec. i. Job Truss truss type U y Fly Utf/U4/ZU2U 81463 1 A09 HIPS 1 1 4288 2479 15714 1 2479 i57X8 III1.5X4 r--7XB F G H =4X6(A1) I t 4=4X6(A1) =7X8 =3X4=H0510 =3X4 =7X10 =3X4 =H0510=3X4 SEA'( PLATE REQ. SEAT PLATE REQ. 2 59'8" 2 I. 63W Loading Criteria (lost) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Sid: 2014 VERT(LL): 0.307 G 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.577 G 999 351 W 3585 /- /- /2070 /825 /468 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.123 N - - N 3585 /- /- /2070 /825 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.232 N Wind reactions based on MWFRS Des Ld: 55.00 Mean Height: 25.00 ft WAVE, HS Creep Factor: 20. W Br Width = 8.0 9 Min Re 4.2 q = NCBCLL: 10.00 TCDL: 5.0 psf p Max TC CSI: 0.784 N Brg Width = 8.0 Min Req = 4.2 Load Duration: 1.25 BCDL: 5.0 psf " Max BC CSI: 0.993 Bearings W & N are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h to 2h Bearings W & N require a seat plate. C&C Dist a: 6.37 ft Max Web CSI: 0.851 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 17.00 ft Wgt: 457.8 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.15 A - B 114 -388 G - H 2861 -4687 Lumber B - C 167 -411 H -1 2794 -4981 C - D 2965 - 5639 I - J 2969 - 5422 Top chord 2x6 SP #2 T2 2x6 SP 2400f-2.OE; D - E 2969 -5422 J - K 2965 -5639 Bot chord 2x6 SP #2 B2,B3 2x6 SP 2400f-2.OE; E - F 2794 -4981 K - L 167 -411 Webs 2x4 SP #3 W1 2x6 SP #2; W2,W7 2x4 SP #2; F - G 2861 -4687 L - M 113 -388 Bracing (a) Continuous lateral restraint equally spaced on member. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Purlins A - V 394 -100 R - Q 4423 -1983 In lieu of structural panels or rigid ceiling use puffins V - U 4195 -2065 Q - P 5129 -2473 to laterally brace chords as follows: U - T 5129 -2472 P - O 5129 -2473 Chord Spacing(in oc) Start(ft) End(ft) T - S 5129 -2472 O - N 4195 -2066 TIC 24 24.21 39.45 BC 79 0.00 63.67 S - R 4423 -1982 N - M 394 -100 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Loading Truss passed check for 20 psf additional bottom chord live load in areas with B - V 490 -497 R - H 502 -306 42"-high x 24"-wide clearance. V - C 2694 -4904 H - Q 683 -195 C - U 1052 -434 Q - 1 563 - 812 Wind U - E 306 -232 1-0 306 -232 Wind loads based on MWFRS with additional C&C member design. E - S 563 -812 O - K 1052 -434 F - S 683 -195 K - N 2694 -4904 Additional Notes F - R 502 -306 N - L 490 -497 WARNING: Fumish a copy of this DWG to the installation contractor. Failure to G - R 452 -604 follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Speclalty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional englneerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the )� 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkVieW Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. C nvdnht 0 2016 A-1 RonfTnisces — Renrnduction of this doncment. in anv fmmo. is nmhihited vrithmd the wdtten nenni. Ginn of A-1 Rnnf Tnrecns. Job I russ I Russ I ype (.try Vly Ut3/U4/LUZU 3987 81433 A10 HIPS 1 1 -R 2279 I 19'2"14 2279 *7X8 1113X4=5X8 =7X8 E F G H T12 5 7X8 ,7X8 D I _ (a) (a) (a rn �4X10 C (a) (a J �4X10 1113X4B K III3X4 I =4X6(A1)A (a) (a L=4X6(A1) U. V U T S R Q P O N M_7X8 =7X8 =3X4=H0510 =3X4 =8X10 =3X4 =H0510=3X4 SEAT PLATE REQ. 2 SEAT PLATE REQ. 2' 59W 63'8" I Loading Criteria (per) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defi L/# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(LL): 0.372 F 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.699 F 999 351 V 3583 /- /- /2062 /844 /428 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.130 M - M 3584 /- /- /2062 /844 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.245 M - Wind reactions based on MWFRS Des Ld: 55.00 Mean Height: 25.00 ft WAVE, HS Creep Factor: 2.0 V Brg Width = 8.0 Min Req = 3.0 NCBCLL 10.00 TCDL: 5.0 psi M Br Width = 8.0 Min Re 3.0 Max TC CSI: 0.914 9 q = Load Duration: 1.25 BCDL: 5.0 sf P Max BC CSI: 0.9Bearings V & M are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: h to 2h Bearings V & M require a seat plate. C&C Dist a: 6.37 ft Max Web CSI: 0.964 64 Maximum Top Chord Forces Per Ply (Ibs) Loc. from l: not in 17.00 ft Wgt: 448.0 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpI: 0.18 i: Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 A - B 136 -506 G - H 3079 -5155 Lumber B - C 205 -531 H - I 2904 -5108 C - D 2984 -5582 I - J 2984 -5584 Top chord 2x6 SP #2 D - E 2904 -5106 J - K 205 -531 Bot chord 2x6 SP 2400f-2.0E B2,B3 2x6 SP #2; E - F 3079 -5155 K - L 136 -506 Webs 2x4 SP #3 W1 2x6 SP #2; W2,W7 2x4 SP #2; l F - G 3078 - 5154 Bracing (a) Continuous lateral restraint equally spaced on member. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Purlins A - U 505 -133 Q - P 4592 -2108 In lieu of structural panels or rigid ceiling use purlins U - T 4434 -2222 P - O 5054 =2447 to laterally brace chords as follows: T - S 5052 -2446 O - N 5054 -2447 Chord Spacing(in oc) Start(ft) End(ft) S - R 5052 -2446 N - M 4436 -2223 TC 241. BC 81 0.21.00 63.67 R - Q 4591 - 2107 M - L 505 -133 Apply puriins to any chords above or below fillers at 24" OC unless shown otherwise above. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Loading Truss passed check for 20 psf additional bottom chord live load in areas with B - U 514 -507 Q - H 798 -471 42"-high x 24"-wide clearance. U - C 2765 -4973 H - P 648 -206 C - T 747 -240 P -1 434 -591 Wind T-D 232 -156 I-N 232 -156 Wind loads based on MWFRS with additional C&C member design. D - R 434 -589 N - J 748 -240 E - R 647 -206 J - M 2765 -4975 Additional Notes E - Q 799 -470 M - K 514 -507 WARNING: Furnish a copy of this DWG to the installation contractor. Failure to F - Q 690 -922 follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the.TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional angineednE Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this, Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the S( Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C nvrinht M 201A A-1 Rnnf Tnnzee." — Reornduoano of f %d—mant. In anv form. is nmhihMd without the vnitlen nannW-Aon of A-1 Rnnf T—s. 1Job Truss Truss Type Qty Ply 08/04/2020 81463 1 A11 I HIPS I 1 1 3984 2079 23714 %7X8(R) =7X8 1113X4 05X6 E F K /117X8(R) H Z 5 X 6 20'2"s :Al) 1114X10 =7X8 =H0510 =3X4 =3X6 =H0510 =4X8 =3X4 =H0510 =7X8 1114X10 SEAT PLATE REQ. SEAT PLATE REQ. 2 59'8" 2 Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 15.00 Speed: 170 mph TPI Sid: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: 25.00 ft WAVE, HS NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 6.37 ft Loc. from endwall: not in 17.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 Bot chord 2x6 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; W2 2x4 SP #2; Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 20.21 43.45 BC 76 0.00 63.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. 63'8" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.441 G 999 3f VERT(CL): 0.827 G 856 3 HORZ(LL): 0.126 M - HORZ(TL): 0.237 M - Creep Factor: 2.0 Max TC CSI: 0.778 Max BC CSI: 0.973 Max Web CSI: 0,948 Wgt: 456.4 lbs VIEW Ver: 19.01.00A.0618.15 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- ! Rh / Rw / U / RL 54 W 3582 /- /- /2048 /864 /391 - M 3583 P P /2048 /864 !- - Wind reactions based on MWFRS W Brg Width = 8.0 Min Req = 4.2 M Brg Width = 8.0 Min Req = 4.2 Bearings W & M are a rigid surface. Bearings W & M require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 329 - 735 G - H 3299 - 5601 B - C 3059 - 5824 H - I 3036 - 5310 C - D 3012 - 5395 I - J 3012 - 5396 D - E 3035 - 5309 J - K 3059 - 5825 E - F 3290 - 5584 K - L 329 - 735 F - G 3298 - 5601 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - W 764 -338 R - Q 5607 -2643 W - V 1135 - 565 Q - P 4840 - 2287 V - U 5229 -2614 P - O 5230 -2616 U - T 5229 -2614 O - N 5230 -2616 T - S 4840 -2286 N - M 1134 -548 S - R 5607 - 2643 M - L 764 - 338 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. W - B 2043 -3330 G - Q 554 -692 B - V 4197 -2069 Q - H 1141 - 654 V - C 396 -426 H - P 483 -143 C - T 387 -468 P - J 388 -467 E - T 479 -142 J - N 396 -427 E - S 1127 -643 N - K 4198 -2070 S - F 561 - 696 K - M 2043 - 3330 F - Q 196 -195 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. ('.onvdnht 0 201a A-1 Rnof Tmr sss— RenrMurlinn of this donrmant. in anv formis nmhihHed withnut tho wrihnn normicsinn of A-1 Roof Tnrecac. Job 81433 Truss Truss Type Al2 I HIPS Qty Ply 08/04/2020 1 it 1 3981 i I 1879 27714 1879 %7X8(R) =3X6 =5X8 =3X6 1117X8(R) 5X6 III1.5X4 a 5X6 E F G H I J 12 5 p D K =4X6(A1)X10 C (a) (a L �5X14X6(A1) B (a) (a) (a (a M N "Y X W V U T S I R Q P "O I 1114X10 =7X8 =H0510 =4X4 =H0710 =4X4 =H0510 =7X8 1114X10 SEA PLATE REQ. SEAT PLATE REQ. 2 59W 2 r 63'8" Loading Criteria (psi Wind Criteria Code / Misc Criteria TCLL: 30.00 Wind Std: ASCE 7-10 Code:FBC 2017 RES TCDL: 15.00 Speed: 170 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: 25.00 ft WAVE, HS NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 6.37 ft Loc. from endwall: not in 17.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 Bot chord 2x6 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; W2 2x4 SP #2; Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 3X4 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 18.21 45.45 BC 71 0.00 63.67 Apply puriins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc Udefl L/# Gravity Non -Gravity VERT(LL): 0.492 H 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.923 H 767 354 Y 3584 A A /2033 /881 /352 HORZ(LL): 0.137 O - O 3584 A A /2033 /881 A HORZ(TL): 0.259 O - - Wind reactions based on MWFRS Creep Factor: 2.0 Y Brg Width = 8.0 Min Req = 4.2 Max TC CSI: 0.737 O Brg Width = 8.0 Min Req = 4.2 Max BC CSI: 0.918 Bearings Y & O are a rigid surface. Max Web CSI: 0.982 Bearings Y & O require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:459.2lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 A - B 214 -489 H - I 3628 -6291 B - C 2997 - 5640 I - J 3462 - 5942 C - D 3087 - 5563 J - K 3102 - 5402 D - E 3102 - 5402 K - L 3087 - 5563 E - F 3462 - 5942 L - M 2997 - 5640 F - G 3628 -6291 M - N 214 -489 G - H 3628 - 6291 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - Y 498 -200 T - S 5978 -2881 Y - X 870 -450 S - R 4998 -2413 X - W 5111 - 2605 R - Q 5111 - 2606 W - V 5111 -2605 Q - P 5111 -2606 V - U 4998 -2412 P - O 870 -409 U - T I 5978 -2880 O - N 498 -200 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Y - B 2007 -3351 T - I 492 -253 B - X 4348 - 2205 I - S 679 - 975 X - C 494 -638 S - J 1448 - 806 C-V 313 -271 J-R 360 -68 E-V 360 -68 R-L 313 -271 E - U 1448 - 806 L - P 494 - 638 U - F 679 -975 P - M 4348 -2205 F - T 492 -253 M - O 2007 -3351 H - T 437 - 609 ' "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES. ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering p.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of thislTruss for any Building is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing.shall be the responsibility of the Building Designer and Contractor. All notes set out in. the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Convriaht 0 2016 A.1 Roof Tnrss a — Re—duntion of this dronment, to anv form. is nmhihfied without the written naml. dno of A4 Ronf Tntcctfc Job Truss Truss Type 81433 A13 HIPS Qty Ply 1 1 1 08/04/2020 4294 I. 16'2"9 =6X10 12 D E 5 F,-,-6X8 C = (a) EZ(.)Z I ZZ 6X8 4X6(A1) =6 f` B J 1 � A a) a N X W V U T S R Q P O N M 31714 .1. 16'2"9 —{ 1111.5X4 =6X10 F G H (Al) =3X4 =6X6 1114X10 =6X6 =4X6 =H0510 =4X8 =H0510 =4X6 =3X4 1114X10 SEAT PLATE REQ. SEAT PLA59'8" 2'TE REQ. 2 Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 6.37 It Loc. from endwall: not in 17.0 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 Bot chord 2x6 SP 2400f-2.OE 131 2x6 SP #2; Webs 2x4 SP #3 W1 2x6 SP #2; W2 2x4 SP #2; Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 7X8 except as noted. Puriins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 16.21 47.45 BC 77 0.00 63.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result in serious injuries. Do not permit inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. 63W Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defi L/# Gravity Non -Gravity VERT(LL): 0.522 F 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.981 F 721 354 X 3578 /- /- /2013 /890 /312 HORZ(LL): 0.115 D - - L 3581 /- /- /2013 /890 A HORZ(TL): 0.217 D - - Wind reactions based on MWFRS Creep Factor: 2.0 X Brg Width = 8.0 Min Req = 4.2 Max TC CSI: 0.833 L Brg Width = 8.0 Min Req = 4.2 Max BC CSI: 0.955 Bearings X & L are a rigid surface. Max Web CSI: 0.965 Bearings X & L require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:439.6lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.15 A - B 193 -432 F - G 3985 -7045 B - C 2936 - 5471 G - H 3741 - 6542 C - D 3152 - 5658 H - I 3152 - 5662 D - E 3741 - 6541 I - J 2936 - 5476 E - F 3985 -7045 J - K 193 -433 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - X 438 -176 R - Q 6589 - 3227 X - W 811 - 393 Q - P 6589 - 3227 W - V 4970 -2561 P - O 5117 -2503 V - U 4970 -2561 O - N 4975 =2562 U - T 5115 -2502 N - M 4975 -2562 T - S 6588 - 3226 M - L 811 - 386 S - R 6588 - 3226 L - K 439 -176 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. X - B 2003 - 3349 R - G 626 - 315 B - W 4269 -2189 G - P 779 -1142 W - C 530 - 753 P - H 1924 -1041 C - U 291 -184 0-1 291 -184 D - U 271 -46 H - O 271 -46 D - T 1926 -1041 1- M 530 - 754 T - E 779 -1143 M - J 4274 -2189 E - R 628 - 315 J - L 2003 - 3352 F - R 493 - 688 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineednE Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. Cnnvriaht 0 2016 A-1 Roof Tatman — Ranrodudi- of thin dnntmant. in anv fnrm. K nmhihhed withnut thn wmtnn mania lnn of A-1 Rmf Tmnnaa. JOD 81433 T io 1� 1 russ I russ I ype Qty Nly A14G MONO 1 1 33W =8X8 =3X4 =5X8 1113X4 =5X8 =3X4 5 �04X10 05X6 1113X4 C D 4X6(A1) B (a) A ra, E F G H I J U8/U4/2U2U 4300 15' �1 =6X10 K o 5X6 :4X10 L M 1113X4 4X6(A1) (a (a N O Y,'X WV U T S R Q P. =H0710 =3X4 =6X8 =4X6 =5X6 =H0710 =5X6 =6X6 =6X8 SEAT PLATE REQ. SEAT PLATE REQ. 59'8" 2' 2 r 63'8" 8'6"4 4' 1 51'1'12 374# 509 Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 6.37 ft Loc. from endwall: not in 17.0( GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 T3 2x6 SP 2400f-2.0E; Bot chord 2x6 SP 2400f-2.0E Webs 2x4 SP #3 W1 2x6 SP #2 W2 2x4 SP #2; Code / Misc Criteria Defl/CSI Criteria Code: FBC 2017 RES PP Deflection in loc Ud TPI Std: 2014 VERT(LL): ' 0.501 H 9' Rep Factors Used: Varies by Ld C %FERT(CL): 0.950 H 7 FT/RT:10(0)/10(10) HORZ(LL): 0.121 P Plate Type(s): HORZ(TL): 0.238 P WAVE, HS Creep Factor: 2.0 Max TC CSI: 0.992 Max BC CSI: 0.999 Max Web CSI: 0.994 I Wgt: 434.7 Ibs VIEW Ver: 19.01.00A.06 Bracing (a) Continuous lateral restraint equally spaced on member Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 78 plf at 0.00 to 78 plf at 63.67 BC: From 20 plf at 0.00 to 20 plf at 15.29 BC: From 50 plf at 15.29 to 50 plf at 18.40 BC: From 20 pif at 18.40 to 20 plf at 23.64 BC: From 50 plf at 23.64 to 50 plf at 26.75 BC: From 20 plf at 26.75 to 20 plf at 36.92 BC: From 50 plf at 36.92 to 50 plf at 40.03 BC: From 20 plf at 40.03 to 20 plf at 45.26 BC: From 50 plf at 45.26 to 50 plf at 48.37 BC: From 20 plf at 48.37 to 20 plf at 63.67 BC: 374 lb Conc. Load at 8.52 BC: 509 lb Conc. Load at 12.52 Purlins In lieu of structural panels or rigid ceiling use pudins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 15.00 48.67 BC 64 0.00 63.67 Apply pudins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Additional Notes WARNING: Furnish a copy of this DWG to the installatic follow provisions of BCSI in handling and installation of Injuries. Do not permit inexperienced and uninstructed r "WARNING" note below. BCSI recommends retaining a engineer for the design of temporary bracing. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. ♦ Maximum Reactions (Ibs) Gravity Non -Gravity ARn Loc R+ / R- / Rh / Rw / U / RL 351 Y 4051 /- /- /- /2073 /- - P 3585 !- /- /- /1601 /- Wind reactions based on MWFRS Y Brg Width = 8.0 Min Req = 3.4 P Brg Width = 8.0 Min Req = 3.0 Bearings Y & P are a rigid surface. Bearings Y & P require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. 15 A - B 602 -1188 H -1 3566 - 7600 B - C 585 -1203 I - J 3566 - 7600 C - D 3168 - 6347 J - K 3182 - 6871 D - E 3136 - 6303 K - L 2518 - 5554 E - F 3402 -7166 L - M 2550 -5605 F - G 3566 - 7600 M - N 56 - 540 contrcV9rHFailuMj% -7600 N - O 68 -515 sses can result in serious tple to install trusses. See :gister®i&l Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - X 1105 - 548 T - S 6926 - 3216 X - W 5082 -2620 S - R 5063 -2284 W - V 5766 - 2854 R - Q 5063 - 2284 V - U 5766 -2854 Q - P 4478 -2063 U - T 7210 - 3429 P - O 514 - 76 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - X 272 -511 T - J 873 -445 X - C 2572 - 5002 J - S 768 -1240 C - W 774 - 257 S - K 2378 -1134 E - W 759 -288 K - Q 223 -84 E - U 2296 - 692 Q - M 750 - 243 U - F 602 -1240 M - P 2492 - 5002 F-T 730 -174 P-N 306 -511 H - T 453 - 733 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin,c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this�Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkUeW Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty E gineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C daht A 2016 A-1 Roof To- -Renrod-Jinn of this dnannant. in anv fnm. is ornhihitad withrnd the written n".rrnicsion of A-1 RmfTnicsas. Job 81433 I Russ A15 Iruss type MONO Ury Fly 1 1 Ut3/U4/ZULU 3958 Loading Criteria (psi) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " T Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP 43 W1 2x6 SP 42; Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 8.46 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others F SEAT PLATE REQ. �— 2' 6'5"8 rL 8'5"8 Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): -0.011 B 999 36( VERT(CL): -0.024 B 999 24( HORZ(LL): -0.004 D - - HORZ(TL): 0.009 B - Creep Factor: 2.0 Max TC CSI: 0.728 Max BC CSI: 0.329 Max Web CSI: 0.282 Wgt: 47.6 Ibs VIEW Ver: 19.01.00A.0618.15 n ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL F 657 /- /- /446 /165 /208 E 321 /- /- /166 /180 /- Wind reactions based on MWFRS F Brg Width = 8.0 Min Req = 1.5 E Brg Width = - Min Req = - Bearing F is a rigid surface. Bearing F requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 243 - 344 C - D 74 -161 B - C 186 - 223 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-F 219 -113 F-E 165 -407 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. F - C 479 -548 D - E 302 -232 C - E 403 -154 —WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn,c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracingshall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrinht 0 2016 A-1 Reef Tn. vu — RxnrndWinn of thin dnr Ant. in env form. in nmhihitnd without the written nnrminsinn of A-1 Reef Tmscas. JV0 81433 =4) K3 A16 HIPS ype 11ty 11y I uofu1rfcucu 13' -r 37'8" =5X6 1111.5X4 =4X6 III1.5X4 =4X6 I SEAT PLATE REQ. SEAT P (ATE REQ. SEAT,PLATE REQ. �- 2' 19, A 18' 5 II 11'3"5 51'1" Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 5.11 ft Loc. from endwall: not in 13.0( GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 T2 2x4 SP M-30; Bot chord 2x6 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2;. Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 3X4 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 13.00 51.02 BC 75 0.00 51.08 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "WARNING" note below. 4303 (R) Defl/CSI Criteria I A Maximum Reactions (Ibs), or •=PLF PP Deflection in loc Udefl U# Gravity Non -Gravity VERT(LL): 0.024 T 999 360 Loc R+ ! R- / Rh / Rw / U / RL VERT(CL): 0.045 T 999 240 V 1235 /- /- /821 /411 /364 HORZ(LL): 0.010 M - - R 1924 /- A /959 /888 /- HORZ(TL): 0.019 M R' 63 /- A /27 /27 /- Creep Factor: 2.0 W 989 /- /- /491 /343 /- Max TC CSI: 0.871 M 581 /- /- /255 /228 /- Max BC CSI: 0.530 WInd reactions based on MWFRS Max Web CSI: 0.862 V Brg Width = 8.0 Min Req = 1.5 R Brg Width = 8.0 Min Req = 2.3 Wgt: 322.7 Ibs R Brg Width = 216 Min Req = - W Brg Width = 11.3 Min Req = 1.5 VIEW Ver: 19.01.00A.06118.15 M Brg Width = - Min Req = - Bearings V, R, R, & W are a rigid surface. Bearings V, R, & W require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 116 - 266 G - H 142 - 98 B - C 166 - 208 H -1 142 - 98 C - D 363 - 781 I - J 142 - 98 D-E 281 -175 J-K 42 -31 E-F 280 -174 K-L 2 -2 F - G 280 -174 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - U 255 - 97 Q - P 183 - 95 U - T 933 - 823 P - O 16 - 36 T-S 611 -421 O-N 16 -36 S-R 611 -421 N-M 284 -216 R - Q 183 - 95 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - U 409 -353 G - P 224 -411 U - C 644 -1180 H - P 436 - 617 C - T 469 - 387 P - J 115 -166 D - T 403 -142 J - N 304 -445 D - R 731 -1072 N - K 358 -456 E - R 604 -789 K - M 303 -398 R - G 327 -484 L - M 158 - 214 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes an this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer),the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the respons'bilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Convdaht 0 201E A-1 Roof To- - RxnmAuntion of this domiment. in anv in=. is nmhihtf A without thn written nanoi, Sinn of A-1 Roof Tnfcwa. Job I russ 814,33 A17G =6X8 12 T T -4) 11 a. Truss Type SPEC city Illy 16'8" -1 37 + 37 18'8" =7X8 =4X4=5X8 =7X8 =5X8 1114X4 08/04/202U 4237 =6X8 (Al) 1115X8(R) =4X8 =4X6 =5X6 =5X6 =5X8 =5X8 =4X8 =5X6 SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ. 2 19'11 "1 20'8"15 19' 2 63W �- 8-6"4 j 4' 151'1"12 374# 509 Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 6.37 ft Loc. from endwali: not in 13.01 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 T2 2x6 SP 2400f-2.OE; Bot chord 2x6 SP 2400f-2.OE B2,B4 2x6 SP #2; Webs 2x4 SP #3 W1 2x6 SP #2; Code / Misc Criteria Defl/CSI Criteria Code: FBC 2017 RES PP Deflection in loc L/defl L/# TPI Std: 2014 VERT(LL): 0.079 T 999 360 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL Rep Factors Used: Varies by Ld C raq_RT(CL): 0.091 Y 999 240 AA 1773 /- P P /910 P FT/RT:10(0)/10(10) HORZ(LL): 0.024 P - - W 2404 /- P /1060 11089 P Plate Type(s): HORZ(TL): 0.040 P - - S 2361 A89 P /1020 /1007 /- WAVE P 1258 / / // 6 Bracing (a) Continuous lateral restraint equally spaced on member. Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 78 plf at 0.00 to 78 pif at 63.67 BC: From 20 plf at 0.00 to 20 plf at 22.40 BC: From -93 plf at 22.40 to -93 pif at 29.81 BC: From -63 pif at 29.81 to -63 plf at 31.86 BC: From -93 pif at 31.86 to -93 plf at 42.33 BC: From 20 plf at 42.33 to 20 pif at 63.67 BC: 374 lb Conc. Load at 8.52 BC: 509 lb Conc. Load at 12.52 Plating Notes All plates are 3X4 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 11.00 27.67 TC 24 34.00 52.67 BC 75 0.00 63.67 Apply pudins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Creep Factor: 2.0 - - - 63 /- Max TC CSI: 0.526 Wind reactions based on MWFRS Max BC CSI: 0.815 AA Brg Width = 8.0 Min Req = 1.5 W Brg Width = 11.3 Min Req = 2.8 Max Web CSI: 0.892 S Brg Width = 8.0 Min Req = 2.0 Wgt: 441.0 Ibs P Brg Width = 8.0 Min Req = 1.5 Bearings AA, W, S, & P are a rigid surface. VIEW Ver: 19.01.00A.0618.15 Bearings AA, W, S, & P require a seat plate. Additional Notes Maximum Top Chord Forces Per Ply (Ibs) WARNING: Furnish a copy of this DWG to the installation contragWr$tiITft faComp. Chords Tens. Comp. follow provisions of BCSI in handling and installation of trusses cca�n suit in iou61 612 H - I 612 -1375 375 injuries. Do not permit inexperienced and uninstructed people to�,tls ll trusj'oP "WARNING" note below. BCSI recommends retaining a register€�tii � fessi 52 I - J - 160 engineer for the design of temporary bracing. C - D 1107 -2097 J - K 338 -160 D - E 727 -436 K - L 338 -160 E - F 343 - 800 L - M 704 -1067 F - G 342 - 800 M - N 228 -192 G - H 407 - 900 N - O 187 -145 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Camp. A-Z 147 -127 U-T 788 -314 Z - Y 1497 - 828 T - S 1265 - 550 Y - X 1847 - 956 S - R 896 - 583 X - W 1847 - 956 R - Q 896 - 583 W - V 440 - 685 Q - P 851 - 557 V-U 788 -314 P-O 96 -125 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B-Z 159 -241 H-T 1033 -512 Z - C 1160 -1970 I - T 738 - 549 C - Y 436 -138 I - S 805 -1831 D - Y 876 -106 K - S 654 -1059 D - W 705 -1664 S - L 458 -1163 W - E 876 -1688 Q - M 153 -128 E-V 1977 -1041 L-Q 371 0 V-G 190 -541 M-P 923 -1318 V - H 99 - 203 P - N 158 - 239 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional ongineedn,c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TOO and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. r:nn mht A 2016 A-1 Rnnf Tnresr_c - Renrnd-11- of thiF dnref. in - fens. m nmhlhited wilhout tha writt- nnnniccinn of A-1 Rnnf Tni-s, doo truss I Fuss I ype try Fry u0/U4/tutu 81433 A18G SPEC 1 16762 91# 191# 191# 2660 27'6"8 57' 5,2" -+ 16,8" =7XB 12 =7X8 1113X4 H T5 p 8X1G2(SRS =8XI2(SRS) C D E F T =4X6(A1) so eI' 03X 10co (a) (a (a) 191#191#191#191 191#277# f f 2' + 2' 2' :46 - 18W 9' 4X4 =7X8 K L M --7X8(" ) (a FR =4X6(A1) (a lrN O AC AB AA Z AD' 'Y X W V U "T S R Q "P =5X8 1113X10 1115X6(R) =3X4 =7X10 1113X8 =4X8 1113X8 =8X14 =4X4 1115X8(R) 1113X10 SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLAT REQ. 17'11'1 22'8"15 19' r 63'8" 9'0"6 ----------170# +170# + 170# 4170# +1701 9 0 6 381# 170# 170# 170# 170# 3184 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: No Deft/CSI Criteria ! PP Deflection in loc L/defl L/# VERT(LL): 0.110 U 999 360 VERT(CL): 0.127 R 999 240 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity LOC R+ / R- / Rh / Rw / U / RL AC 2137 /- A /- /1655 /- BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.035 N AD 2428 A /- /407 /2362 A Des Ld: 55.00 EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.046 N - T 2787 /- /- /293 /2545 A Mean Height: 25.00 ft WAVE Creep Factor: 2.0 P 2241 /- /- /- /1602 /- NCBCLL: 10.00 TCDL: 5.0 sf p Max TC CSI: 0.772 Wind reactions based on MWFRS Load Duration: 1.25 " BCDL: 5.0 psf Max BC CSI: 0.982 AC Brg Width = 8.0 Min Req = 2.5 Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 AD Brg Width = 11.3 Min Req = 2.9 C&C Dist a: 6.37 ft Max Web CSI: 0.906 T Brg Width = 8.0 Min Req = 3.3 Loc. from endwall: not in 17.00 ft Wgt: 446.6 Ibs P Brg Width = 8.0 Min Req = 2.6 GCpi: 0.18 ! Bearings AC, AD, T, & P are a rigid surface. VIEW Ver: 19.01.00A.0618.15 Wind Duration: 1.60 Bearings AC, AD, T, & P require a seat plate. Lumber Purlins Maximum Top Chord Forces Per Ply (Ibs) Top chord 2x6 SP #2 In lieu of structural panels or rigid ceiling use puriins Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x6 SP #2 to laterally brace chords as follows: A - B 142 -247 H -1 961 -1534 Webs 2x4 SP #3 W1,W5 2x6 SP #2; Chord Spacing(in oc) Start(ft) End(ft) W10 2x8 SP 2400f-1.8E; g _ C 2611 -2871 TC 24 9.00 25.67 I - J 694 -739 TC 24 36.00 54.67 C - D 2224 - 2298 J - K 694 - 739 Bracing BC 48 0.00 63.67 D - E 577 -733 K - L 694 - 739 (a) Continuous lateral restraint equally spaced on member. Apply puriins to any chords above or below fillers E - F 577 -733 L - M 2314 -2603 at 24" OC unless shown otherwise above. F - G 577 -733 M - N 2526 -3074 Special Loads G - H 960 -1536 N - O 127 -250 Additional Notes (Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) WARNING: Furnish a copy of this DWG to the installation contr r TC: From 93 plf at 0.00 to 93 plf at 63.67 20.40 follow provisions of BCSI in handling and installation of trusses 8fci N a& Chord fttRc € ' t Forces Per Ply (Ibs) BC: From 20 plf t . 00 to 20 plf at BC: From -93 plf at 20.40 to -93 plf at 42.33 injuries. Do not permit inexperienced and uninstructed people SS, p. to Ins masses. ee Chords Tens. Comp. BC: From 20 plf at 42.33 to 20 plf at 63.67 "WARNING" note below. BCSI recommends retaining a registerW_grpfessir2,gl -139 V - U 1763 -1266 TC: 91 lb Conc. Load at 9.00 engineer for the design of temporary bracing. AC -AB 462 -331 U - T 1810 -1289 TC: 266 lb Conc. Load at 9.03 AB -AA 2538 -2339 T - S 2542 -2271 TC: 191 lb Conc. Load at 11.06,13.06,15.06,17.06 AA-Z 2238 -2179 S - R 2542 -2271 44.60,46.60,48.60,50.60,52.60 Z - Y 2238 - 2179 R - Q 2727 - 2262 TC: 277 lb Conc. Load at 54.64 Y - X 1516 -1106 Q - P 477 - 310 TC: 103 lb Conc. Load at 54.67 X - W 1-1 P - O 259 -124 BC: 381 lb Conc. Load at 9.03 W - V 176363 -1266 6 BC: 170 lb Conc. Load at 11.06,13.06,15.06,17.06 44.60,46.60,48.60,50.60,52.60 BC: 318 lb Conc. Load at 54.64 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Plating Notes All plates are 5X6 except as noted. AC- B 1669 -1978 W -1 510 -489 B -AB 2199 -2042 I - U 1270 - 644 (")1 plate(s) require special positioning. Refer to scaled plate plot details for C -AB 315 -403 I - T 1104 -2319 special positioning requirements. C -AA 635 -455 K - T 546 - 808 Wind AA- D 892 -810 T - L 2742 -3637 D -Y 2568 -3196 L- R 883 -710 Wind loads and reactions based on MWFRS. E - Y 419 -627 R - M 382 -295 Y - G 1127 - 2294 M - Q 319 -163 X - G 1147 - 580 Q - N 2379 -1986 G - W 310 -264 N - P 1622 -2083 H - W 1384 - 864 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER")ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn,c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitabilityand use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 047182 use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C nvdaht 0 2016 A-1 Rod Trii-i - Renmfurlinn of thin dnaiment. in anv fnnn. is nmhihitrd withoid thn wrihnn renniminn of A-1 Rnof Tn�c a. Job 814133 Truss Truss Type B01 G I MONO Qty I Ply 1 08/04/2020 7572 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 0'1 1- 7' 86# 6Y7 6 2 2'13�sio• 8 -75'6 -{ i 13715 2.0.2 1 13715 ia5X6 1k5X6 D E SEAT PLATE REQ. SEAT PLATE REO. �2-A 24'8• 28'8• 70.6 6'3.11 r 6'3'S 7V12 804# 52 5299 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 13.0( GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 T1 2x4 SP M-30; Sot chord 2x6 SP 2400f-2.0E Webs 2x4 SP #3 W1 2x8 SP 2400f-1.8E; Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: No FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Bracing (a) Continuous lateral restraint equally spaced on member. Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 93 plf at 0.00 to 93 plf at 28.67 BC: From 20 plf at 0.00 to 20 plf at 28.67 TC: 86 lb Conc. Load at 7.00,21.22 TC: 162 lb Conc. Load at 13.28,15.38 BC: 804 lb Conc. Load at 7.03 BC: 529 lb Conc. Load at 13.34,15.33 BC: 805 lb Conc. Load at 21.60 Purlins In lieu of structural panels or rigid ceiling use puffins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 13.33 15.34 BC 56 0.00 28.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): -0.143 K 999 360 VERT(CL): 0.191 K 999 240 HORZ(LL): -0.044 C - - HORZ(TL): 0.057 1 - - Creep Factor: 2.0 Max TC CSI: 0.918 Max BC CSI: 0.997 Max Web CSI: 0.812 Wgt: 169.4 Ibs VIEW Ver. 20.01.01A.0724.11 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL M 3244 A A /- /2421 A 1 3239 A A A /2219 A Wind reactions based on MWFRS M Brg Width = 8.0 Min Req = 2.7 1 Brg Width = 8.0 Min Req = 2.7 Bearings M & I are a rigid surface. Bearings M & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 927 - 993 E - F 2754 - 3828 B - C 890 - 995 F - G 569 - 981 C - D 2762 -3830 G - H 604 - 981 D - E 2462 - 3429 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - L 889 -805 J -1 3349 -2376 L - K 3348 -2502 I - H 876 -523 K - J 3429 - 2462 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - L 295 - 353 E - J 1049 - 573 L - C 2137 - 3185 J - F 402 -133 C- K 406 0 F- I 2339 - 3197 D - K 1067 - 683 1= G 289 - 339 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 0471ne responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 82 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. C nvriaht W 2016 A-1 Rnnf Tnmm - Renrndudinn of this dmirnant. in anv fnnn. N nmhihhad withnut the written nermLcclnn of A-1 Rmf Tn� cns. JOD 1 russ I Russ I ype Ury I I Fly UtSIU4/'LULU 81433 B02 COMN 14 1 4085 14'4" 14'4" SEAT PLATE REQ. SEAT PLATE REQ. �-- 2' 24'6" i j 2' I 28W Loading Criteria (psr) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.500' Rt Slider: 2x4 SP #3; block length = 1.500' Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 28.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. 1113X6(E5) Defl/CSI Criteria ♦ Maximum Reactions. (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.054 E 999 360 Loc R+ / R- / Rh / Rw / U / RL N 1620 !- /- /866 /869 1208 VERT(CL): 0.103 E 999 240 HORZ(LL): 0.027 J - - J 1620 /- /- /866 /869 /- HORZ(TL): 0.052 J - - Wind reactions based on MWFRS Creep Factor: 2.0 N Brg Width = 8.0 Min Req = 1.9 Max TC CSI: 0.936 J Brg Width = 8.0 Min Req = 1.9 Max BC CSI: 0.880 Bearings N & J are a rigid surface. Max Web CSI: 0.455 Bearings N & J require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:151.2lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.061i3.15 A- B 301 -286 E - F 1034 -1668 B - C 229 -258 F - G 299 -212 C - D 299 -212 G - H 229 -258 D - E 1034 -1668 H - I 301 -286 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - M 253 -164 K - J 1462 -753 M - L 1462 - 753 J -1 253 -164 L - K 1241 - 504 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - M 294 -272 E - K 336 -126 M - D 1109 -2025 K - F 272 -66 D - L 272 -66 F - J 1109 -2025 L - E 336 -126 J - G 294 -272 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. verify design parameters and read notes on this Truss Design Drawing (rDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated ion the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, inthecontext of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any,field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in thejTDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C vd"ht 0 2016 A-1 Rmf Tnmcr-c — Renn d-11m of this doarmont. In anu fnm. is omhihited w0hnut the wrMnn —1-inn of A-1 Rmf Tnns . Job Truss Truss Type city Fly U3/U4/2ULU 81433 B03 COMN 3 1 14W SEAT PLATE REQ. �2'— 1 25'g" s4X4 4062 Loading Criteria (psf) Wind Criteria Code I Misc Criteria DeflICSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udefl L/# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(LL): 0.051 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.096 J 999 240 L 1593 /- /- /854 /416 /226 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.021 H - - H 1311 /- P /632 /354 P EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.040 H Wind reactions based on MWFRS Des Ld: 55.00 Mean Height: 25.00 ft WAVE Creep Factor: 20. L Br Width = 8.0 Min Re 1.9 9 q = NCBCLL: 10.00 TCDL: 5.0 sf p Max TC CSI: 0.886 H Brg Width = - Min Req = - Load Duration: 1.25 BCDL: 5.0 psf Bearing L is a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: h to 2h Max BC CSI: 0.807 Bearing L requires a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.587 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 Wgt: 140.0 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 19.01.00&0618.15 A - B 328 -283 D - E 823 -1531 Lumber B - C 267 -248 E - F 852 -1531 C - D 822 -1685 F - G 769 -1516 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; Maximum Bot Chord Forces Per Ply (Ibs) Lt Slider: 2x4 SP #3; block length = 1.500' Chords Tens.Comp. Chords Tens. Comp. Bracing A - L 253 -195 J -1 1439 -703 (a) Continuous lateral restraint equally spaced on member. L - K 127 -219 1- H 5 -7 K - J 1564 - 766 Purlins In lieu of structural panels or rigid ceiling use purlins Maximum Web Forces Per Ply (Ibs) to laterally brace chords as follows: Webs Tens.Comp. Webs Tens. Comp. Chord Spacing(in oc) Start(ft) End(ft) L - C 878 -1516 J - F 237 -217 BC 75 0.00 25.75 Apply purins to any chords above or below fillers C - K 1542 -708 F - I 374 -514 at 24" OC unless shown otherwise above. K - D 328 -421 I - G 1502 - 710 D - J 269 -294 G - H 695 -1294 Wind E - J 434 -98 Wind loads based on MWFRS with additional C&C member design. "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerinc Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C—rinht W 2016 A-1 Roof Tnrasns — R—durlino of this doarment. in anv torn. is nmhlhited without the wdttnn permission of A-1 Roof ToLGCP_C. ion 81433 I russ B04 i 14'4" I russ I ype COMN Qty Ply 08/04/2020 4 1 11'8"12 SEAT PLATE REQ. 1 . 2' 24'0"12 r 26'0"12 Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.500' Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT;10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 26.06 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads based on MWFRS with additional C&C member design. Defl/CSI Criteria PP Deflection in loc VERT(I-Q: 0.054 J VERT(CL): 0.103 J HORZ(LL): 0.022 H HORZ(TL): 0.042 H Creep Factor: 2.0 Max TC CSI: 0.885 Max BC CSI: 0.810 Max Web CSI: 0.604 Wgt:140.0 Ibs VIEW Ver. 19.01.00A.061 =4X4 4065 T 1 ♦ Maximum Reactions (Ibs) L/# Gravity Non -Gravity 360 Loc R+ / R- / Rh / Rw / U / RL 240 L 1610 /- /- /860 /421 /224 - H 1329 /- /- /641 /358 P - Wind reactions based on MWFRS L Brg Width = 8.0 Min Req = 1.9 H Brg Width = - Min Req = - Bearing L is a rigid surface. Bearing L requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. 15 A - B 328 -282 D - E 841 -1566 B - C 266 -247 E - F 870 -1567 C - D 835 -1710 F - G 832 -1652 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - L 253 -195 J -1 1548 - 748 L-K 132 -218 I-H 9 -11 K - J 1589 - 769 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. L - C 886 -1533 J - F 252 -256 C - K 1563 -718 F - I 344 -454 K - D 332 -428 I - G 1584 -740 D - J 269 -285 G - H 705 -1307 E-J 452 -112 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptanoe'of the professional engineedn Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer,. in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C' nvrioht C) 2n16 A-1 R—f Tn.--- Renrod,,M. Inn of this dom-Ant. in anv fnnn. in nmhihhnd without the wriftnn nennicsinn of A-1 Ronf Inn —es. Job 81483 Truss C01 G Truss Type HIPS city I Nly I Ub/U4/2U1U 1 1 6768 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 434 33# 33# 43# 4-2'0"6.-.#'0:#-.2'0'6 C5X6 5' 9' 2-0.12 18110"6 j 2'0°12--­l 23' Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: 11 EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.500' Rt Slider: 2x4 SP #3; block length = 1.500' Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 92 pIf at 0.00 to 92 pIf at 9.00 TC: From 46 pIf at 9.00 to 46 plf at 14.00 TC: From 92 plf at 14.00 to 92 pIf at 23.00 BC: From 20 plf at 0.00 to 20 plf at 9.03 BC: From 10 plf at 9.03 to 10 plf at 13.97 BC: From 20 plf at 13.97 to 20 pIf at 23.00 TC: 43 lb Conc. Load at 9.03,13.97 TC: 33 lb Conc. Load at 11.06,11.94 BC: 21 lb Conc. Load at 9.03,13.97 BC: -6 lb Conc. Load at 11.06,11.94 Purlins In lieu of structural panels or rigid ceiling use pudins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 14.00 BC 75 0.00 23.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Left and right cantilevers are exposed to wind 4 21# Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE -6#} 21#+ Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.029 D 999 36 $fERT(CL): 0.055 D 999 24 HORZ(LL): 0.012 G - HORZ(TL): 0.023 G - Creep Factor: 2.0 Max TC CSI: 0.778 Max BC CSI: 0.453 Max Web CSI: 0.315 Wgt: 121.8lbs VIEW Ver: 19.01.00A.0618.15 93X6(E5) ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL M 1252 /- /- /- /561 /- 1 1252 /- /- /- /561 /- Wind reactions based on MWFRS M Brg Width = 3.1 Min Req = 1.5 1 Brg Width = 3.1 Min Req = 1.5 Bearings M & I are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 144 - 287 E - F 474 -1243 B-C 140 -137 F-G 144 -134 C - D 477 -1246 G - H 147 -285 D - E 346 -1034 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - M 177 -73 K - J 1033 -345 M - L 305 -92 J -1 302 - 93 L - K 1033 -345 1- H 174 -75 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - C 659 -1136 E - J 108 - 66 C - L 827 -262 J - F 826 -257 D-L 113 -60 F-I 657 -1139 L-E 16 -12 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depleted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4620 ParkVieW Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C nvrinht a) 2171116 A-1 Rnnf Tn,-- R.-rin Linn of this dmrment. in anv fnrn. is nmhihNerl whhoot thn wdhan narnicsinn of A-1 Roof Tntcsas. Job 81433 I russ Truss Type CO2 I MONO City Ply 08/04/2020 1 1 4050 .7X6-7X6 D E �- 2,0"12 18'10"8 2,0"12 i 23' Loading Criteria (psQ Wind Criteria Code / Misc Criteria TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 15.00 Speed: 170 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 T2 2x4 SP #2; Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #Z- Lt Slider: 2x4 SP #3; block length = 1.500' Rt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 11.00 12.00 BC 109 0.00 23.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind 1113X6(E5) Defl/CSI Criteria I ♦ Maximum Reactions (Ibs) PP Deflection in loc Udefl L/# Gravity Non -Gravity VERT(LL): 0.026 E 999 360 Loc R+ / R- / Rh / Rw / U / RL M 1301 /- /- 1717 1691 1160 VERT(CL): 0.050 J 999 240 HORZ(LL): -0.015 G - 1 1301 /- /- 1717 /691 A HORZ(TL): 0.028 G - - Wind reactions based on MWFRS Creep Factor: 2.0 M Brg Width = 3.1 Min Req = 1.5 Max TC CSI: 0.913 1 Brg Width = 3.1 Min Req = 1.5 Max BC CSI: 0.970 Bearings M & I are a rigid surface. Max Web CSI: 0.463 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wgt:127.41bs � A - B 298 - 564 E - F 725 -1293 B - C 156 -292 F - G 156 -292 C - D 725 -1293 G - H 296 - 564 VIEW Ver. 19.01.00A.0618.15 i D - E 799 -1047 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - M 351 -188 K - J 1047 - 418 M - L 484 - 322 J -1 484 - 284 L - K 1047 -418 I - H 351 -188 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M-C 880 -1181 E-J 191 -104 C - L 666 - 303 J - F 666 - 303 D - L 192 -104 F - I 880 -1181 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TOD represents an acceptan< responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this I responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The appn use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in tht guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the respons: Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty En, Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. convrinht 0 2o16 A-1 Rmf Tnresas - Rennxturlinn of this dmiment. in anv form. Is nmhihhsd wirhnut tha wdttan nermiscinn of A-1 Rmf Tmsses. ;KNOWLEDGMENT" form. i the TDD, only Alpine of the professional engineers iss for any Building is the al of the TDD and any field 'Do and the practices and litres and duties of the Truss ieer Is NOT the Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job Truss Truss Type Qty I Ply 08/04/2020 81433 1 CO3 I COMN 1 1 4053 11'6" �— 2-0.12 11'6° E=4X4 16'10'8 2'0'12 23' 1113X6(E5) Loading Criteria (psq Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/deft L/# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(LL): 0.041 K 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.076 K 999 240 L 1301 /- /- f713 /413 /167 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.016 J - - J 1301 /- /- /713 /413 /- EXP: C : NA Plate Type(s): HORZ(TL): 0.031 J - - Wind reactions based on MWFRS Height: Mean Height: 25.00 ft WAVE Creep Factor: 2.0 L Brg Width = 3.1 Min Req = 1.5 NCBDes CLLd: 10.00 ton: BCDL: 5.0 psf Max TC CSI: 0.435 J Br Width = 3.1 Min Re 1.5 g q = Load Du: Load Duration: 1.25 BCDL: 5.0 psf " Max BC CSI: 0.908 Bearings L & J are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Max Web CSI: 0.596 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 Chords Tens.Comp. Chords Tens. Comp. Wgt: 121.8 Ibs GCpi: 0.18 A - B 321 -428 E - F 638 -1159 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.15 B - C 104 -188 F - G 121 -205 Lumber C - D 122 -205 G - H 103 -188 D - E 638 -1159 H - I 321 -428 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; Maximum Bot Chord Forces Per Ply (Ibs) Lt Slider: 2x4 SP #3; block length = 1.500' Chords Tens.Comp. Chords Tens. Comp. Rt Slider: 2x4 SP #3; block length = 1.500' A - L 417 -247 K - J 1082 -490 Purlins L - K 1082 -489 J - 1 417 -169 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Maximum Web Forces Per Ply (Ibs) Chord Spacing(in oc) Start(ft) End(ft) Webs Tens.Comp. Webs Tens. Comp. BC 75 0.00 23.00 Apply purlins to any chords above or below fillers C - L 287 -234 K - F 220 -113 at 24" OC unless shown otherwise above. L - D 778 -1291 F - J 778 -1291 D - K 220 -113 J - G 287 - 234 Wind E - K 357 -70 Wind loads based on MWFRS with additional C&C member design Left and right cantilevers are exposed to wind "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkVieW Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the _ St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. C.n daht 6) 2016 A-1 Rnof Tnimm — Renmdi0ion of thin dnutment. in anv fern. N nrohihited wilhout the written nnnniccion of A-1 Rnof Tni—q. JOO 81433 I russ I russ I ype ury rry C04 COMN 1 1 Ut$fU4/LULU 4194 90 EO EO m1 T P to 1 9'5"4 C=AVA 9'5"4 1.5X3 Loading Criteria (pso Wind Criteria Code / Misc Criteria Defl/CSI Criteria I ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udefl L/# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Sid: 2014 VERT(LL): 0.035 G 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.065 G 999 240 H 1062 /- /- /514 /360 /137 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.016' F - - F 1062 /- /- /514 /360 P EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.030 F - Wind reactions based on MWFRS Des Ld: 55.00 Mean Height: 25.00 ft WAVE Creep Factor: 2.0 H Br Width = 3.1 Min Re 1.5 9 q = NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.426 F Brg Width = 3.1 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 p sf " Max BC CSI: 0.703 Bearings H & F are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h/2 to h Max Web CSI: 0.667 Maximum Top Chord Forces Per Ply (Ibs) C&C Dist a: 3.00 ft Chords Tens.Comp. Chords Tens. Comp. Loc. from endwall: not in 9.00 f Wgt: 102.2 Ibs GCpi:0.18 A-B 81 -91 C-D 691 -1236 Wind Duration: 1.60 VIEW Ver. 19.01.00A.06181.15 B - C 691 -1236 D - E 81 -91 Lumber Top chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Bot chord 2x4 SP M-30 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP #3 H-G 1181 -632 G-F 1181 -631 Purlins In lieu of structural panels or rigid ceiling use purlins Maximum Web Forces Per Ply (Ibs) to laterally brace chords as follows: Webs Tens.Comp. Webs Tens. Comp. Chord Spacing(in oc) Start(ft) End(ft) A - H 158 -149 G - D 259 -146 BC 120 0.00 18.87 Apply purlins to any chords above or below fillers H - B 777 -1417 D - F 777 -1417 at 24" OC unless shown otherwise above. B - G 259 -146 E - F 158 -149 C - G 415 -119 Wind Wind loads based on MWFRS with additional C&C member design. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACrNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on. the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information. (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terrhs are as defined in TPI-1. Cnnvrinht M 2016 A-1 Rnnf Tmssas — Ranmdudion of this domiment. in am forth. is nmhihited without tha wridan nennissinn of A-1 Ronf Tmcsas. Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job 81433 Truss D01 G Truss Type Qty Ply COMN 1 1 08/04/2020 4252 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " TV12- r'l, 14lin 10 i10'91-1191114___371-�y-ty . T3'2 i 27-1 ---1-179 -I^ 27-1 -{- 44'3 12 3.36 p e5X6 0SX6 D E T T 12 /6X6D 2F�6X6 5� fn G e fi1.5X3 B 11 (a) c3X4(B1)A Li L J I H e7 6 WX6 -4X4 ®SX10(R SEAT PLATE REQ. �-- 2' 167 Wind Criteria Code / Misc Criteria Wind Std: ASCE 7-10 Code: FBC 2017 RES Speed: 170 mph TPI Std: 2014 Enclosure: Closed Rep Factors Used: No Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Mean Height: 25.00 ft WAVE TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x6 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; Bracing (a) Continuous lateral restraint equally spaced on member. Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 93 plf at 0.00 to , 93 plf at 7.26 TC: From 46 plf at 7.26 to 46 plf at 14.07 TC: From 93 plf at 14.07 to 93 plf at 18.42 BC: From 20 plf at 0.00 to 20 plf at 7.15 BC: From 10 plf at 7.15 to 10 plf at 14.18 BC: From 20 plf at 14.18 to 20 plf at 18.42 TC: 58 lb Conc. Load at 7.15,14.18 TC: 247 lb Conc. Load at 8.96,12.38 TC: 396 lb Conc. Load at 9.84,11.50 TC: 191 lb Conc. Load at 10.66 TC: 72 lb Conc. Load at 17.94 BC: 72lb Conc. Load at 7.15,14.18 BC: 100 lb Conc. Load at 8.96,12.38 BC: 353 lb Conc. Load at 9.84,11.50 BC: 170 lb Conc. Load at 10.66 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.85 11.48 BC 57 0.00 18.42 Apply puriins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. 18'5" i 100# i17J +100N �4713� 72# 353# 353# 72# B 1.5X4 T 1 Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc Udefl L/# Gravity Non -Gravity VERT(LL): -0.084 D 999 360 Loc R+ / R- ! Rh / Rw / U / RL VERT(CL): 0.114 1 999 240 L 2390 /- !- /- /1714 P HORZ(LL): -0.033 G - - H 2189 P P P /1621 /- HORZ(TL): 0.045 G - - Wind reactions based on MWFRS Creep Factor: 2.0 L Brg Width = 8.0 Min Req = 2.8 Max TC CSI: 0.665 H Brg Width = - Min Req = - Max BC CSI: 0.986 Bearing L is a rigid surface. Max Web CSI: 0.730 Bearing L requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:113.4lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.15 A - B 112 -232 D - E 2175 -2893 B - C 102 - 262 E - F 2302 - 3054 C - D 2302 - 3053 F - G 105 -136 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - K 228 - 96 J -1 2893 - 2175 K - J 2523 -1930 1- H 2446 -1885 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. S - K 334 -421 E - I 150 -37 K - C 2336 -2999 1- F 840 -470 C - J 773 -397 F - H 2338 -3027 D - J 90 -29 G - H 213 -263 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seat on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. r-niaht ® 2016 A-1 RnnfTnisses- Renroduntinn of this dnnrment. in anv form. is nrahihitnd without the written nermission of A-1 Rnnf Tmsses. Job Truss Truss Type Qty Ply 08/04/2020 81433 D02 I COMN 2 1 1 4029 10'8" SEAT PLATE REQ. 2' 16'5" 7'9" al r 18'5" _I Loading Criteria (psf) Wind Criteria Code / Misc Criteria TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 15.00 Speed: 170 mph TPI Sid: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2;. Lt Slider: 2x4 SP #3; block length = 1.500' Purtins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing()n oc) Start(ft) End(ft) BC 75 0.00 18.42 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Deft/CSI Criteria PP Deflection in loc L/defll L/# VERT(LL): 0.021 D 9991 361 VERT(CL): 0.038 D 9991 241 HORZ(LL): -0.006 B - HORZ(TL): 0.012 B - Creep Factor: 2.0 Max TC CSI: 0.609 Max BC CSI: 0.682 Max Web CSI: 0.437 Wgt: 98.0 Ibs VIEW Ver: 19.01.00A.0618. 4X4(R) T m 0 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL 1 1186 /- /- /663 /622 /172 F 896 P P /431 /498 P Wind reactions based on MWFRS I Brg Width = 8.0 Min Req = 1.5 F Brg Width = - Min Req = - Bearing I is a rigid surface. Bearing I requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 265 -456 C - D 603 -1091 B - C 143 - 219 D - E 595 -1069 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A -1 221 - 95 H - G 334 - 284 I - H 334 -284 G - F 68 -46 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. I - C 784 -1068 G - E 828 - 383 C - G 638 -299 E - F 538 -832 D - G 208 - 92 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACK�JOWLEDGMENT' fore. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilitle's and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in wrifing by all parties involved. The Specialty Engineer is NOT the .S( Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvdnht A 2n16 A-1 Ronf Tnissm — Renrorinntion of this document. In anv form. is nrohihhed withnut the vmhen nenniasion of A-1 Rmf Tn� caw. 1Job Truss Truss Type Qty Ply 08/04/2020 81433 D03 COMN 4 1 1 4032 to t r 1113X6(E5) T 1OW SEAT PLATE REQ. �-- 2' 16'8"12 18'8"12 8'0"12 Loading Criteria (psf) Wind Criteria Code I Misc Criteria Defl/CSI Criteria TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# TCDL: 15.00 Speed: 170 mph TPI Sid: 2014 VERT(LL): 0.022 D 999 361 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.041 D 999 241 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.006 B - - EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.012 B - - Des Ld: 55.00 Mean Height: 25.00 ft WAVE Creep Factor: 2. NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf 0 Max TC CSI: 655 Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.710 C&C Dist a: 3.00 ft Max Web CSI: 0.448 Loc. from endwall: not in 9.00 Wgt: 98.0 Ibs GCpi: 0.18 VIEW Ver: 19.01.00A.0618.15 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 18.73 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads based on MWFRS with additional C&C member design. ,-4X4 I m 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL 1 1203 A /- /668 /377 /170 F 914 A A /439 /312 /- Wind reactions based on MWFRS I Brg Width = 8.0 Min Req = 1.5 F Brg Width = - Min Req = - Bearing I is a rigid surface. Bearing I requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 257 -447 C - D 584 -1129 B - C 146 - 220 D - E 597 -1114 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens:Comp. Chords Tens. Comp. A -1 213 - 91 H - G 329 - 283 I - H 329 - 283 G - F 85 - 55 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. I - C 791 -1086 G - E 845 - 360 C - G 680 - 322 E - F 546 - 846 D - G 207 - 80 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS end CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' forth. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerinE Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss. Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C nvrlaht 0201e A-1 Ronf hisses—RAnrr dantinn of this dnnrment. in anv form. is nmhihited without the written narnisslon of A-1 RonfTnisces. Job Truss 81433 1 E01G Truss Type HIPS 1ty II y I as/oarzozo 1 ,6756 T 12 5� e �6X10 B E3X4(Bt)A 11 M M4X10 SEAT PLATE REQ. f^2'j J Ilk i 191# 191# g�# 191# 26 20"64-2191i(-,1"41�1'4i 2,2,061 10'4° ®6X8 m3X3 C D E6X8 E �1�%6X10 L K J I c6X6 �4X8mV6 M6X6 �1 F 9 0"6 17 y + 1701f + + 17pti 1 381# 170# 170# Loading Criteria (psQ Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 13.01 GCp): 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x6 SP #2 Webs 2x4 SP #3 W1 2x8 SP 2400f-1.8E; W2 2x4 SP #2; Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. . Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 93 plf at 0.00 to 93 pif at 9.00 TC: From 46 plf at 9.00 to 46 plf at 19.33 TC: From 93 plf at 19.33 to 93 plf at 28.33 BC: From 20 plf at 0.00 to 20 plf at 9.03 BC: From 10 plf at 9.03 to 10 plf at 19.30 BC: From 20 plf at 19.30 to 20 plf at 28.33 TC: 91 lb Conc. Load at 9.00,19.33 TC: 266 lb Conc. Load at 9.03,19.30 TC: 191 lb Conc. Load at 11.06,13.06,14.17,15.27 17.27 BC: 381 lb Conc. Load at 9.03,19.30 BC: 170lb Conc. Load at 11.06,13.06,14.17,15.27 17.27 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 19.33 BC 42 0.00 28.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 381# i Defl/CSI Criteria PP Deflection in loc L/defl U# VERT(LL): -0.245 D 9991 36i %:RT(CL): 0.288 D 985 24, HORZ(LL): -0.050 C - - HORZ(TL): 0.059 C - 1 - Creep Factor: 2.0 Max TC CSI: 0.746 Max BC CSI: 0.978 Max Web CSI: 0.836 Wgt: 166.6 lbs VIEW Ver: 19.01.00A.0618A5 Wind Wind loads and reactions based on MWFRS. Left and right cantilevers are exposed to wind Left bottom chord exposed to wind. H SEAT PLATE REQ. f 2' -I ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL M 2949 6 /- /- /2522 /- H 2949 P P /- /2522 /- Wind reactions based on MWFRS M Brg Width = 8.0 Min Req = 3.5 H Brg Width = 8.0 Min Req = 3.5 Bearings M & H are a rigid surface. Bearings M & H require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 104 -219 D - E 4436 -4832 B -C 3956 -4269 E - F 3956 -4269 C - D 4436 -4832 F - G 104 -218 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - M 224 -95 J - I 3832 -3564 M - L 705 - 553 I - H 705 - 553 L - K 3832 -3564 H - G 224 -94 K -J 3832 -3564 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - B 2558 -2809 K - E 1293 -1106 B - L 3275 - 3077 E - I 62 -120 j C - L 62 -120 1- F 3275 - 3077 C - K 1293 -1106 F - H 2558 - 2810 D - K I 712 - 894 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 0471ne responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 82 use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. Al notes set out In the TDD�and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BBC[) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineerlis NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. Cnovdnht 0 21116 A-1 Rnnf Tnixces - Renrndunim M this dnannnnt. in snv fnnn. is nrnhihlted without the written nermissinn of A-1 Roof Tmcces. Job Truss Truss Type City Ply 11810412020 81433 E02 HIPS 1 1 11' 6'4" 11' e 5X8 E =5X6 F =4X6 -3X4 =-3X6 =3X8 =4X6 SEAT PLATE REQ. 2' j— Loading Criteria (pst) Wind Criteria Code / Misc Criteria TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 15.00 Speed: 170 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 10.00 Risk Category: II FT/RT:10(0)/l0(10) EXP: C Kzt: NA Plate Type(s): Des Ld: 55.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP M-30 B2 2x4 SP #2; Webs 2x4 SP #3 W1 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.500' Rt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 11.00 17.33 BC 66 0.00 28.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Left bottom chord exposed to wind. SEAT PLATE REQ. 24'4" j 2' —� 28'4" 3923 1113X6(E5) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.047 L 999 360 Loc R+ / R- / Rh / Rw / U / RL p 1602 /- /- /1314 /944 1160 VERT(CL): 0.090 L 999 240 HORZ(LL): 0.022 K - - K 1602 /- /- /929 /835 /- HORZ(TL): 0.043 K - - Wind reactions based on MWFRS Creep Factor: 2.0 P Erg Width = 8.0 Min Req = 1.9 Max TC CSI: 0.595 K Brg Width = 8.0 Min Req = 1.9 Max BC CSI: 0.999 Bearings P & K are a rigid surface. Max Web CSI: 0.657 Bearings P & K require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:158.2lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.15 A - B 507 -421 F - G 2193 -1646 B - C 183 -131 G - H 384 -257 C - D 225 -102 H -1 365 - 319 D - E 2165 -1645 I - J 749 - 612 E - F 2135 -1437 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-0 141 -122 M-L 1434 -1781 O - N 1229 -1339 L - K 1228 -1476 N - M 1434 -1781 K - J 309 - 280 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - O 236 -249 L - F 458 -524 O - D 1837 -1774 L - G 470 -424 D - N 348 - 523 G - K 1730 -1772 E - N 430 -507 K - H 297 -250 E - L 116 -101 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional enginearinE Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. Cnnvdnht 0 2016 A-1 Rmf Tmcsas — Renr dadion of this dmrmnnt. in anv form. is nmhihited withnut the written nermissinn of A-1 Roof Tnrccec_ Job 81433 Truss Truss Type E03 I HIPS City Ply 08/04/2020 1 1 3926 Co 1113X6(E5) Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 13' 2'4" 1 i 13' =5X6 =5X6 1113X6 =4X4 =3X4=3X6 =3X4 i=4X4 1113X6 I SEAT PLATE REQ. SEAT PLATE REQ. 2' j 24'4" j 2' --- Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.500' Rt Slider: 2x4 SP #3; block length = 1.500' Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 13.00 15.33 BC 73 0.00 28.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Left bottom chord exposed to wind. K-E111 Defl/CSI Criteria PP Deflection in loc L/defl � L/# VERT(LL): 0.076 O 9991 36 VERT(CL): 0.139 M 999 ` 24 HORZ(LL): 0.026 E - - HORZ(TL): 0.044 E - - Creep Factor: 2.0 Max TC CSI: 0.544 Max BC CSI: 0.968 Max Web CSI: 0.552 Wgt: 162.4 Ibs VIEW Ver. 19.01.00A.0618. 1113X6(E5) ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL Q 1601 /- /- /1299 /872 /189 K 1601 /- /- /922 /775 /- Wind reactions based on MWFRS Q Brg Width = 8.0 Min Req = 1.9 K Brg Width = 8.0 Min Req = 1.9 Bearings Q & K are a rigid surface. Bearings Q & K require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 201 -118 F - G 2040 -1539 B - C 212 -42 G - H 2272 -1787 C-D 2217-1787 H-1 212 -212 D - E 2061 -1539 I - J 333 - 255 E - F 1959 -1329 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-Q 67 -140 N-M 1329 -1612 Q - P 264 -186 M - L 1575 -1965 P - O 1575 -1878 L - K 228 - 304 O-N 1329 -1612 K-J 210 -140 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Q - C 1673 -1498 F - M 368 - 582 C - P 1449 -1804 M - G 491 - 401 P - D 239 -263 G - L 287 -263 D - O 382 -401 L - H 1449 -1734 E - O 377 - 612 H - K 1516 -1498 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT form. Verify design parameters and read notes on this Truss Design Drawing (TOO) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TOO, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (I.e. Specialty Engineer), the seal on any TOO represents an acceptance of the professional enginserin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047162 responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of!ithe TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilitiesland duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. Cnnvrinht ®4Ma A-1 Rnnf Tnr. vs� — Rnnmd,,d- of thie dnntmnnt. in -form. is omhihBntl without Mn w,itt.n —!.Won of A-1 Rmf Tnrecr-c. Job 81483 Truss E04 12'2" Truss Type COMN Qty Ply 08/04/2020 4 1 T 12'2" C=H0710 4190 1.5X3 SEAT PLATE REQ. 24'4" SEAT PLATE REQ. Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(LL): 0.055 C 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.103 C 999 240 1 1369 /- /- /1079 /733 /177 BCDL: 10.00 Risk Category: II FT/RT:10(0)110(10) HORZ(LL): 0.028 F - - J 1369 /- A 1898 1733 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.052 F - - Wind reactions based on MWFRS Des Ld: 55.00 Mean Height: 25.00 ft WAVE, HS Creep Factor: 2.0 1 Brg Width = 8.0 Min Req = 1.6 NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.693 J Br Width = 8.0 Min Re 1.6 g q = Load Duration: 1.25 BCDL: 5.0 psf p " Max BC CSI: 0975 Bearings I & J are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h/2 to h . Bearings I & J require a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.885 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 Wgt: 130.2 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.15 A - B 136 -80 C - D 2386 -1835 Lumber B - C 2411 -1836 D - E 116 -99 Top chord 2x4 SP M-30 Bot chord 2x4 SP M-30 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 Chords Tens.Comp. Chords Tens. Comp. Purlins I - H 1646 -1844 G - F 1645 -1839 H - G 1423 -1601 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) Maximum Web Forces Per Ply (Ibs) BC 93 0.00 24.33 Webs Tens.Comp. Webs Tens. Comp. Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. A -1 99 -36 C - G 491 -848 I - B 2262 - 2070 G - D 614 - 345 Loading B - H 384 -333 D - F 2250 -2068 Truss passed check for 20 psf additional bottom chord live load in areas with H - C 687 -839 E - F 57 -59 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Left bottom chord exposed to wind. **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Co Mht Q 2016 A-1 Roof T.-- Renmd-11- of thin d—ment. in anv form. is nmhlhHed withmrt thn wriman nemricninn of A-1 Ronf Tmacr_c. Job 81433 Truss Truss Type Qty G01 I FLAT 11II 2y 602# 1252ry 1301# 1301 106J If10+ 1'10'15T2'- t 2'-2'-41-5.3�( lIIW(8 1 1 F„ =6X10 H13X90 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NC13CLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP #2 Bot chord 2x6 SP #2 Webs 2x6 SP #2 W2 2x4 SP #2; W3 2x4 SP #3; Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 2 Rows @ 5.00" o.c. (Each Row) Bot Chord: 1 Row @ 4.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. (1)1/2" bolts may be used for (2) 0.131"x3", min. nails on Either The Top or Bottom Chords. Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac =1.25) TC: From 90 plf at -0.63 to 90 plf at 2.04 TC: From 45 psf at 2.04 to 45 plf at 9.52 BC: From 20 plf at -0.63 to 20 plf at 2.21 BC: From 10 pif at 2.21 to 10 plf at 9.52 TC: 602 lb Conc. Load at 0.17 TC: 1252 lb Conc. Load at 2.08 TC: 1301 lb Conc. Load at 4.08, 6.08 TC: 1062 lb Conc. Load at 8.09 BC: 914 lb Conc. Load at 2.25, 4.25, 6.25, 8.25 10'1"12 {�-210°9-'j2' 2'j2' 4# I1-3"4-� 914# 91 914# 9141J Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl IU# VERT(LL): 0.048 B 999 I36( VERT(CL): 0.088 B 999 1 24( HORZ(LL): 0.007 A - - HORZ(TL): 0.013 A - - Creep Factor: 2.0 Max TC CSI: 0.800 Max BC CSI: 0.603 Max Web CSI: 0.642 Wgt: 179.2 Ibs VIEW Ver. 19.01.00A.0618.1 08/04/2020 6771 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL F 4704 P P P /2029 /131 D 5176 P P P /1999 P Wind reactions based on MWFRS F Brg Width = 7.8 Min Req = 2.8 D Brg Width = - Min Req = - Bearing F is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 980 -2384 B - C 980 -2384 Wind I Maximum Bot Chord Forces Per Ply (Ibs) Wind loads and reactions based on MWFRS. Chords Tens.Comp. Chords Tens. Comp. Left end vertical exposed to wind pressure. Deflection meets L/36G.E 50 -57 E - D 63 -22 Right end vertical not exposed to wind pressure. i Maximum Web Forces Per Ply (Ibs) Additional Notes Truss must be installed as shown with top chord up. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.00 10.15 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Webs Tens.Comp. Webs Tens. Comp. A - F 973 - 2187 B - E 1199 -1973 A - E 2845 -1126 C - D 850 - 2135 E - C 2829 -1169 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verity design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on thejTDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance ofthe professional engineers responsibility for the design of the single Truss depleted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI.1. The approval of the TDD and any field use of the Truss. Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. C.n daht 0) 2016 A-1 Roof Tnresr_c - Ranrod-Alon of ftq done-ont. in anv torn. is nmhihlt"d without tha writlnn nnrmiminn of A-1 Ronf Trij- Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job 81433 Truss Truss Type Oty Ply G02 I FLAT 1 2 08/04/2020 7575 Loading Criteria (psQ TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 1 1 602# 1301# 1062# I= 1 1'10'15252t{ 2 2 1301 111,�X6 10'1 "12 �- 3'1 "9 i 2' 2 2 1'0"4 132�13� 132132 Wind Criteria Code / Misc Criteria Wind Std: ASCE 7-10 Code: FBC 2017 RES Speed: 170 mph TPI Std: 2014 Enclosure: Closed Rep Factors Used: No Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Mean Height: 25.00 ft WAVE TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Deft/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.050 B 999 360 VERT(CL): 0.092 B 999 240 HORZ(LL): 0.008 A - - HORZ(TL): 0.015 A - Creep Factor: 2.0 Max TC CSI: 0.751 Max BC CSI: 0.768 Max Web CSI: 0.700 Wgt: 190.4 Ibs VIEW Ver. 20.01.01A.0724.11 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL F 5194 P P P /2975 /131 D 6352 P /0 P /3693 /0 Wind reactions based on MWFRS F Brig Width = 7.8 Min Req = 3.1 D Brg Width = - Min Req = - Bearing F is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 1556 -2667 B - C 1556 -2667 Lumber Wind Maximum Bot Chord Forces Per Ply (Ibs) Top chord 2x6 SP #2 Wind loads and reactions based on MWFRS. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x6 SP #2 Left end vertical exposed to wind pressure. Deflection meets L/360.E 124 -104 E - D 274 -159 Webs 2x8 SP 2400f-1.8E W2 2x4 SP #2; W3 2x4 SP #3; Right end vertical not exposed to wind pressure. Maximum Web Forces Per Ply (Ibs) Nailnote Additional Notes Webs Tens.Comp. Webs Tens. Comp. Nail Schedule:0.131 "x3", min. nails Truss must be installed as shown with top chord up. A - F 1386 -2382 B - E 1121 -1879 Top Chord: 2 Rows @ 5.00" D.C. (Each Row) A - E 3101 -1770 C - D 1367 -2330 Sot Chord: 2 Rows @ 5.50" o.c. (Each Row) E - C 3085 -1801 Webs : 1 Row @ 4" D.C. Use equal spacing between rows and stagger nails in each row to avoid splitting. (1)112" bolts may be used for (2) 0.131"x3", min. nails on Either The Top or Bottom Chords. Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 90 plf at -0.63 to 90 plf at 2.08 TC: From 45 plf at 2.08 to 45 plf at 9.52 BC: From 20 plf at -0.63 to 20 plf at 2.50 BC: From 10 plf at 2.50 to 10 pif at 9.52 TC: 602 lb Conc. Load at 0.17 TC: 1252 lb Conc. Load at 2.08 TC: 1301 lb Conc. Load at 4.08, 6.08 TC: 1062 lb Conc. Load at 8.09 BC: 1329 lb Conc. Load at 2.50, 4.50, 6.50, 8.50 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.00 10.15 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPIA. The approval of the TOO and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TOO and the practices and 4620 ParkView Dr guidelines of the Building Component Safety information (BSCI) published by TPI and SSCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrinht PJ 2016 A-1RonfTntcsrts-Ranrndunlinn of IN.%dn-Ant. in anv form. is nmhihitnd without the wri[tan nerniccinn of A-1 RnnfTnt ,,. JOO 1 russ 81433 G03 I russ I ype ury r'ly FLAT 1 1 Ut$/U4/1ULU 3964 to N 7 IIIA3X4(R) 1111.Y4 1111.5X3 1113X6(% i 3'10"8 —� �-- 1'11"4 — — 1-11"4 --� 321# Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria I ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl I L/# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(LL): -0.001 B 999 1360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Varies by Ld C §4_RT(CL): 0.001 B 999 1240 D 374 /- /- /- /136 /153 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.001 A - - C 374 /- /- /- /290 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.001 A - I, - Wind reactions based on MWFRS Des Ld: 55.00 Mean Height: 25.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Creep Factor: 2.0 D Brg Width = - Min Req = - Max TC CSI: 0.394 C Brg Width = - Min Req = - Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.913 Maximum Top Chord Forces Per Ply (Ibs) S" 1 C&C Dist a: 3.00 ft Max Web CSI: 0.285 I Chords Tens.Comp. Loc. from endwall: not in 13.00 ft A - B 7 -12 GCpi:0.18 Wgt:29.41bs 1 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.15 Maximum Bot Chord Forces Per Ply (Ibs) Lumber Chords Tens.Comp. Top chord 2x4 SP #2 D - C 13 -84 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Maximum Web Forces Per Ply (Ibs) Special Loads Webs Tens.Comp. Webs Tens. Comp. —(Lumber Dur.Fac.=1.25 / Plate Dur.Fac =1.25) I A - D 68 -174 B - C 140 -174 TC: From 90 plf at 0.00 to 90 plf at 3.88 I A - C 108 0 BC: From 20 plf at 0.00 to 20 pif at 3.88 BC: 321 lb Conc. Load at 1.94 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 47 0.00 3.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Hangers / Ties (J) Hanger Support Required, by others Wind 1 Wind loads and reactions based on MWFRS. Left end vertical exposed to wind pressure. Deflection meets L/360. Right end vertical not exposed to wind pressure. Additional Notes Truss must be installed as shown with top chord up. I 11 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (rDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the! professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by aContract agreed upon in writing by all parties Involved. The Specialty Engineer Is1, NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrinht Q 2016 A-1 Roof Tn�, cac— RrnrM,,,jI- of thLa dmi—t. In anv form. In mmhihttrd withmR thn written nnnnicdnn of A-1 Ronf Tn— Job Truss 81433 I G04 Truss Type COMN 1ty I Ply 108/04/2020 4234 Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 13.001 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP M-30 Webs 2x4 SP 43 Special Loads —(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 93 plf at 0.00 to 93 plf at 3.88 BC: From 20 plf at 0.00 to 20 plf at 3.88 BC: 581 lb Conc. Load at 1.94 Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 1.33 3.88 BC 47 0.00 3.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others 1'4" -+— 2'6"8 —� 12 5 p 5F5X6 1111.5X4 B C III 1.5X3 v 1113X6(R) 1- 3'10"8 �--1'11"4-1-1-11"4�{ 581# Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): -0.001 C 999 36 10-ERT(CL): 0.001 C 999 24 HORZ(LL): -0.005 A - - HORZ(TL): 0.005 A - - Creep Factor: 2.0 Max TC CSI: 0.183 Max BC CSI: 0.923 Max Web CSI: 0.501 Wgt: 44.8 Ibs ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL E 509 /- /- /- /109 /199 D 509 /- /- /- /365 /- Wind reactions based on MWFRS E Brg Width = - Min Req = - D Brg Width = - Min Req = - Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 127 -24 B-C 0 0 VIEW Ver: 19.01.00A.0618.15 I Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Wind loads and reactions based on MWFRS. E - D 28 -81 Left end vertical exposed to wind pressure. Deflection meets L/360. Right end vertical not exposed to wind pressure. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A - E 91 - 62 B - D 195 - 68 E-B 0 -121 C-D 93 -117 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' forth. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering p.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin,c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. C.onvdoht 0 2016 A-1 Ronf Tn,--- RenroduoHon of thie dminnent. in anv fn=. in nmhiNfed without tha written nnrmi. Ginn of AA Rnnf Tni—q. Job I cuss 81433 HJ3 I russ I ype ttty I Ply HIP_ 2 1 08/U4/2020 4166 r , 1114X6(E5) 4 -356# - 14 4'3i 1- 2715 2'8IIll --{ n SEAT PLATE REQ. �- 273 �i E 9'10"1 I -389# i Loading Criteria (psi) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udefl L/# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(LL): -0.336 G 235 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Varies by Ld C qq--RT(CL): -0.350 G 226 1 240 H 523 /-451 /- /- /1330 /- BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.159 D - - F 93 /-84 /- /- /298 P EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.162 D - - E 86 P P P /91 P Des Ld: 55.00 Mean Height: 25.00 ft WAVE Creep Factor. 2.0 Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 5.0 sf p Max TC CSI: 0.451 H Brg Width = 11.3 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 psf " Max BC CSI: 0.703 I F Brg Width = 1.5 Min Req = - Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 E Br Width = 1.5 Min Re 9 q C&C Dist a: 3.00 It Max Web CSI: 0.456 Bearing H is a rigid surface. Loc. from endwall: not in 9.00 f Wgt: 43.4 Ibs Bearing H requires a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. Lumber A - B 535 - 97 C - D 529 -16 Top chord 2x4 SP 2400f-2.OE B - C 440 0 D - E 28 - 30 Bot chord 2x4 SP 2400f--2.OE Webs 2x6 SP #2 W2 2x4 SP #3; Lt Slider. 2x4 SP #3; block length = 1.518' Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Special Loads . -(Lumber Dur.Fac1.25 / Plate Dur.Fac.=1.25) A - H 0 -404 G - F 0 0 TC: From 2 calf at 0.00 to 2 calf at 9.84 H-G 0 -398 BC: From 20 plf at 0.00 to 20 plf at 4.29 i BC: From 2 plf at 4.29 to 2 plf at 9.84 I Maximum Web Forces Per Ply (Ibs) TC: -356 lb Conc. Load at 4.29 Webs Tens.Comp. Webs Tens. Comp. TC: 142 lb Conc. Load at 7.12 BC: -389 lb Conc. Load at 4.29 C - H 358 -254 D - G 486 0 BC: -5 lb Conc. Load at 7.12 i Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 9.84 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Additional Notes Negative reaction(s) of -451# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. -WARNING' Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering p.e. Specialty Engineer), the seal on any TDD represents an acceptance of the'professional engineedn Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for'any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer,.in the context of the IRC, the IBC, local building code and TPI-1. The approval ofthe TDD and any field # 047182 use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. Al notes set out In the TDD and the practices and 4620 ParkVfew Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1, j Convdaht m) 2016 A-1 Roof T.--Ranmdudino of this dormant, in anv form. is nmhihhnd without ins "itan nonnissino of A-1 RnnfTnicsas. I Job 81433 russ Truss Type HJ5 I HIP_ 2 I y 108/04/2020 4023 Loading Criteria (psi) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NC13CLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " mI Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac. 1.25) TC: From 2 plf at 0.00 to 2 plf at 7.96 BC: From 20 plf at 0.00 to 20 plf at 4.45 BC: From 2 plf at 4.45 to 2 plf at 7.96 TC: -2 lb Conc. Load at 4.45 TC: 105 lb Conc. Load at 6.15 BC: -47 lb Conc. Load at 4.45 BC: 19 lb Conc. Load at 6.15 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 7.96 Apply purlins to any chords above or below Fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. m4x6(E5) -2# �-476 T 18"810 1 9"11-I D SEAT PLATE REQ. I-- 72.12 -­1 `^ 79"15 51119 T11'8 i 1 -474 19#1 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udefl U# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.186 F 181 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Varies by Ld C §1=_RT(CL): 0.219 F 154 240 G 445 /- /- /- /147 /- FT/RT:10(0)/10(10) HORZ(LL):-0.094 C - - E 72 /- A /- /64 /- Plate Type(s): HORZ(TL): 0.102 C D 58 /- /- /- /108 A WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.435 G Brg Width = 8.9 Min Req = 1.5 Max BC CSI: 0.395 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.059 D Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. Wgt: 30.8 Ibs Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A - B 99 - 52 C - D 39 - 38 B-C 82 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-F 0 -51 F-E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C-F 107 -210 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn,c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SECA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the .St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. G-daht 0 2016 A-1 Roof TmL ns - Renrodurdinn of this dnatment. in anv form. is nrmhibited without the wddan nsrmissinn of A-1 Roof Tn� cr-c. JOD 81433 Loading Criteria (psi) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " I cuss I cuss I ype r.,iry I rry uafu4f�u�u HJ6 HIP_ 2 I 1 -569q f 6t _ GI Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt• NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W2,W3 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 2.476' Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 2 plf at 0.00 to 2 plf at 11.66 BC: From 2 pif at 3.36 to 2 plf at 11.66 TC: -569 lb Conc. Load at 4.29 TC: 60 lb Conc. Load at 7.12 TC: -141 lb Conc. Load at 7.12 TC: 217 lb Conc. Load at 9.94 TC: 106 lb Conc. Load at 9.95 BC: -60 lb Conc. Load at 4.29 BC: 57 lb Conc. Load at 7.12 BC: -38 lb Conc. Load at 7.12 BC: 157 lb Conc. Load at 9.94 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 36 3.13 6.26 BC 65 6.21 11.66 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. .,.5X4 SEAT PLATE RESEAT PLATE REO. l�2.9.4- j -14.3-_i 7569 I- 32' I--aYa't1-{ �4'3'6 -6eq 4.11'1 I 5525`14 -38tJ , Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udefl IL/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): -0.098 F 797 j360 Loc R+ / R- ! Rh / Rw / U / RL Rep Factors Used: Varies by Ld C 15NERT(CL): 0.081 A 443 240 M 49 /-445 /- /- /165 /- FT/RT:10(0)/10(10) HORZ(LL): -0.020 J - - L 465 /-136 /- /- /1765 /- Plate Type(s): HORZ(TL): 0.037 G - I - H 364 !- /- /- /309 /- WAVE Creep Factor: 2.0 G 162 /- /- P /128 P Max TC CSI: 0.841 Wind reactions based on MWFRS Max BC CSI: 0.914 M Brg Width = 11.2 Min Req = 1.5 Max Web CSI: 0.254 L Brg Width = 11.3 Min Req = 1.5 H Brg Width = 1.5 Min Req = - Wgt: 72.8 Ibs G Brg Width = 1.5 Min Req = - Bearings M & L are a rigid surface. VIEW Ver. 20.01.01A.0724.11 Bearings M & L require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 76 0 D-E 129 0 B-C 80 0 E-F 149 -89 C - D 149 -189 F - G 46 - 36 Additional Notes Negative reaction(s) of -445# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. M-L 0 -71 K-1 3 -43 L-J 0 -45 I-H 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-N 0 -87 J-K 111 -141 C-N 316 -86 J -E 185 -111 N - M 309 -88 E - I 59 -3 D - L 1212 -186 F - I 185 -286 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNO Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the 7 connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of tt use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD al guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities a Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. r-rinht W 2m,6 A-1 Ranf Tno-- RanrMnotim of ihK d-niont. in anu trio. is nmhihhnd withnut tha wriden narmiacinn of A-1 Rmf Tni- LEDGMENT' form. D, only Alpine ofessional engineednE Manuel Martinez, P.E. TDD lldiis the any # 047182 and field the practices and 4620 ParkView Dr I duties of the Truss OT the St Cloud, FL 34771 Job r 81433 Truss Truss l ype HJ7 I HIP_ city Vly 2 1 UU/U4/2ULU 6765 Loading Criteria (psQ TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " mI m4x6(E5) Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: If EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.518' Special Loads (Lumber Dur.Fac.=1.25 / Plate Dur.Fac =1.25) 14 I^1-e•13-{^r6•10!rs°15 --t 2-9-15-0--re•11�i SEAT PLATE REQ. SEAT PLATE REQ. I-- 2'9'3 T6'8 �- 4'3'7 -389# TC: From 91 pif at 0.00 to 91 pif at 4.29 TC: From 46 pif at 4.29 to 46 plf at 9.94 TC: From 91 plf at 9.94 to 91 plf at 12.67 BC: From 20 plf at 0.00 to 20 plf at 4.29 BC: From 10 plf at 4.29 to 10 plf at 9.94 BC: From 20 plf at 9.94 to 20 plf at 12.67 TC: 72 lb Conc. Load at 1.74 TC: -356 lb Conc. Load at 4.29 TC: 142 lb Conc. Load at 7.12 TC: 350 lb Conc. Load at 9:94 BC: -389 lb Conc. Load at 4.29 BC: -5 lb Conc. Load at 7.12 BC: 126 lb Conc. Load at 9.94 Purlins In lieu of structural panels or rigid ceiling use purins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 55 0.00 12.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Left cantilever is exposed to wind Left bottom chord exposed to wind. 10'5'7 2'2'9 -12'8• -5#} i 126# Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE PI Defi/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): 0.066 B 327 36, S,tRT(CL): 0.068 B 321 24, HORZ(LL): -0.012 D - HORZ(TL): 0.013 C - Creep Factor: 2.0 Max TC CSI: 0.717 Max BC CSI: 0.996 Max Web CSI: 0.419 Wgt: 60.2 Ibs VIEW Ver: 19.01.00A.0618.15 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL H 506 /-158 /- /- 11846 /- 1 888 /- /- /- /1463 /- F 27 /-19 /- /120 /- /- E 10 /-90 /- 1143 /- /- Wind reactions based on MWFRS H Brg Width = 11.3 Min Req = 1.5 1 Brg Width = 11.3 Min Req = 1.5 F Brg Width = 1.5 Min Req = - E Brg Width = 1.5 Min Req = - Bearings H & I are a rigid surface. Bearings H & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 677- - 24 C - D 273 -176 B-C 671 0 D-E 86 -68 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-H 0 -570 G-F 0 0 H - G 0 - 522 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. H - C 997 -491 D - G 984 - 803 C - G 533 0 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C-naht 9) 21116 A-1 Rnof Tmacr_c- Rnnrodudinn of this doatmont. in anv fnnn. is nmhih9ad without the wrihan nnrmi. sinn of A-1 Rnnf Tn-_c. .foo truss 1 russ 1 ype ury rfy uQ/u4rZUZu 81433 HJ7A HIP_ 3 1 �6753 62x4(B1 4 Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: If EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP M-30 Bot chord 2x6 SP 2400f-2.0E Webs 2x6 SP #2 W2 2x4 SP #3; Special Loads (Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 2 plf at 0.00 to 2 pif at 12.67 BC: From 20 plf at 0.00 to 20 pif at 4.29 BC: From 2 plf at 4.29 to 2 pif at 12.67 TC: -356 lb Conc. Load at 4.29 TC: 142 lb Conc. Load at 7.12 TC: 342 lb Conc. Load at 9.94 BC: -389 lb Conc. Load at 4.29 BC: -5 lb Conc. Load at 7.12 BC: 120 lb Conc. Load at 9.94 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 100 0.00 12.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Left cantilever is exposed to wind Left bottom chord exposed to wind. 43"7 �5 14 2715 2715- t li2-8.11-�{ �,,. SEAT PLATE REQ. �-273 12'a" ? ? + -38g# 120# Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl LI/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): -0.386 F 293 360 Loc R+ / R- / Rh / Rw / U ! RL Rep Factors Used: Varies by Ld CRT(CL): -0.400 F 282 240 H 606 /-328 /- /- /1605 /- FT/RT:10(0)/10(10) HORZ(LL): -0.167 C - - D 166 P /- /- /152 /- Plate Type(s): HORZ(TL): 0.170 C I E 211 /- /0 /- /504 /0 WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.675 I H Brg Width = 11.3 Min Req = 1.5 Max BC CSI: 0.986 I D Brg Width = 1.5 Min Req = - Max Web CSI: 0.472 E Brg Width = 1.5 Min Req = - Bearing H is a rigid surface. Wgt: 56.7 Ibs Bearing H requires a seat plate. VIEW Ver: 19.01.00A.0618.15I Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 632 -199 C - D 115 - 93 B - C 750 -232 Additional Notes Negative reaction(s) of -328# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-G 187 -601 F-E 0 0 G - F 199 - 593 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. I B - G 471 -157 C - F 751 - 270 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOW Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TD connector plates shall be used for the TDD to be valid. As a Truss Design Engineering Q.e. Specialty Engineer), the seal on any TDD represents an acceptance of the Or responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for a responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specially Engineer Is N Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. (:nnvriaht 9) 2m16 A-1 Roof Tnrc m - Renroduction of thin dormant. in anv form. is nmhihited without the written na niaainn of A-1 Roof Tniacea. an form. Building Is the TDD and any field the practices and d duties of the Truss OT the Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job I russ • 81483 HJ7B I russ I ype HIP c try rly U0/U4/LULU 1 1 6759 4m4X6(E5) Loading Criteria (pst) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP 2400f-2.0E Bot chord 2x4 SP 2400f-2.0E Webs 2x6 SP #2 W2 2x4 SP #3; Lt Slider. 2x4 SP #3; block length = 1.518' Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 2 plf at 0.00 to 2 plf at 12.66 BC: From 20 plf at 0.00 to 20 plf at 4.29 BC: From 2 plf at 4.29 to 2 plf at 12.66 TC: 1 lb Conc. Load at 4.29 TC: 142 lb Conc. Load at 7.11 TC: 342 lb Conc. Load at 9.94 BC: 675 lb Conc. Load at 4.29 BC: -5 lb Conc. Load at 7.11 BC: 120 lb Conc. Load at 9.94 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 12.66 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. 1 4-3.7 'i' Z9°15 1- 1 2715 t 2-8.11 H Diana SEAT PLATE REQ. i' 4'0'12----'I i 675# Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE 12'8' -54t 4 120# Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): -0.443 G 223 36 qq-:RT(CL): -0.476 G 208 24 HORZ(LL): -0.158 D - - HORZ(TL): 0.164 D - - Creep Factor: 2.0 Max TC CSI: 0.657 Max BC CSI: 0.775 Max Web CSI: 0.308 Wgt: 51.8 Ibs VIEW Ver. 19.01.00A.0618.15 E ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL H 1066 /- /- /- /626 /- E 189 /- /- /- /200 /- F 148 /- P P /246 P Wind reactions based on MWFRS H Brg Width = 8.0 Min Req = 1.5 E Brg Width = 1.5 Min Req = - F Brg Width = 1.5 Min Req = - Bearing H is a rigid surface. Bearing H requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 275 -183 C - D 297 -198 B-C 276 -147 D-E 101 -86 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-H 159 -264 G-F 0 0 H - G 154 - 264 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - H 77 - 358 D - G 333 - 205 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (I.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn,c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SECA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. C nvrinht 0) 2016 A-1 Roof Tnr. vsa- R.-d.,dinn of this dnannent. in env form. is omhihitad without the written nnrmirdnn of A-1 Roof Tn- goo truss 1 russ type Wry cry uaiu4ftutu 81433 HJ8 HIP_ 2 1 4017 Loading Criteria (psi) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " -3X4(B1) tnj Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 17.0( GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x6 SP #2 Webs 2x6 SP #2 W2 2x4 SP #3; Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 92 plf at 0.00 to 92 plf at 9.99 BC: From 20 plf at 0.00 to 20 plf at 9.99 TC: 24 lb Conc. Load at 4.80 TC: 105 lb Conc. Load at 6.15 TC: 232 lb Conc. Load at 9.35 BC: -31 lb Conc. Load at 4.80 BC: 19 lb Conc. Load at 6.15 BC: 93 lb Conc. Load at 9.35 r Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 107 0.00 9.99 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. 24# ,0 i 4'9"10 �#- 1'4"3 D SEAT PLATE REQ. I` T2.12 I I 9'11"14 I I -31# 19# 93# Code / Misc Criteria Defl/CSI Criteria I ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udefi L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): -0.120 G 258 360 Loc R+ / R- / Rh / Rw / U / RL G 844 /- /- /- /657 /- Rep Factors Used: Varies by Ld C FNERT(CL): 0.170 G 182 240 FT/RT:10(0)/10(10) HORZ(LL): 0.063 D - I - E 353 /- /0 /- /209 /0 Plate Type(s): HORZ(TL): 0.088 D - I - D 396 /- /- /- /364 A WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.802 G Brg Width = 8.9 Min Req = 1.5 Max BC CSI: 0.993 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.252 D Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. t Wgt: 44.1 Ibs Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. I A - B 441 -443 C - D 139 -127 B - C 480 - 502 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKN Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of th responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss f( responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvriaht 0) 201E A-1 Roof Tne,-i - Renrodurlion of thLs document. in anv in=. In nmhihitnd withnut the written nennl Wnn M A-1 Roof Tnt>;cex. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-G 416 -397 F-E 0 0 G - F 414 - 393 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - G 339 -418 C - F 502 -526 -EDGMENr' form. D, only Alpine ofessional engineerin Manuel Martinez, P.E. Is the Buildld any TDD # 047182 anfield the practices and 4620 ParkView Dr duties of the Truss DT the St Cloud, FL 34771 Job 81433 I russ muss -type J1 I JACK city I ply 14 1 US/U4/2U2U 3908 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " T 1 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in cc) Start(ft) End(ft) BC 36 0.00 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 1113X6(E5) D 5"4 SEAT PLATE REQ. f- 2' -{ 2'6"12 I` 3' T 1 Code / Misc Criteria Defi/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udefl U# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.061 F 503 360 Loc R+ / R- / Rh / Rw / U / RL G 1157 /- /- /1070 /546 /103 Rep Factors Used: Yes VERT(CL): 0.108 F 284 240 FT/RT:10(0)/10(10) HORZ(LL): -0.034 D - - D - /-429 /- /168 1352 P Plate Type(s): HORZ(TL): 0.060 D E - /-401 P /203 /418 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.429 G Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.439 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.163 E Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. Wgt: 16.8 Ibs Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A - B 203 - 337 C - D 219 -177 B - C 135 - 251 Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Left bottom chord exposed to wind. Additional Notes Negative reaction(s) of -429# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-F 294 -67 F-E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 1051 - 660 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER') ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TOO) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TOO, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TOO and the practices and 4620 ParkView Dr guidelines of the Building Component Safety information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrinht 0 2016 A-1 Rnnf T.-- Ranmdudion of this do—nnt. in anv form. is nmhihaed withottl the written nermircion of A-1 Rmf Tnisses. JOD 81433 1 Russ J1A i russ I ype JACK ury 2 UOfu4/LULU 3949 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 1113X6(E5) T a0 i Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 36 0.00 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 12 5 C� 1111.5X4 3X4B j H B 0' ao A I 1113X6 p Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defi L�, Gravity Non -Gravity TPI Sid: 2014 VERT(LL): -0.022 B 900 360 Loc R+ / R- / Rh / Rw / U / RL D 337 /- /314 /300 /175 /282 Rep Factors Used: Yes VERT(CL): 0.033 B 602 240 FT/RT:10(0)/10(10) HORZ(LL): -0.010 B - �- C - /- /314 /- /- /290 Plate Type(s): HORZ(TL): 0.014 B - ;- Wind reactions based on MWFRS WAVE Creep Factor: 2.0 D Big Width = 1.5 Max TC CSI: 0.459 C Brg Width = 1.5 Max BC CSI: 0.187 I Maximum Top Chord Forces Per Ply (Ibs) Max Web CSI: 0.167 Chords Tens.Comp. Chords Tens. Comp. A - B 564 -768 B - C 404 - 643 Wgt:16.81bs VIEW Ver. 19.01.00A.0618.15 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A - D 695 - 316 Wind 1 Wind loads based on MWFRS with additional C&C member design. Additional Notes The maximum horizontal reaction is 314# 1 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNO Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the l connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of it use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD ai guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities a Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. Cnovriaht Q 2016 A-1 RonfTn--Renrodur]inn of this domimant, in anv form. is omhihiled withal thn writtnn narmislnn of A-1 Roof Trip . Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. D - C 546 -284 form. TDD and any field the practices and I duties of the Truss OT the Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job Truss Truss I ype ury rly uu/u4/LU14u 4306 81483 IAB JACK 4 1 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: > 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x6 SP 42 Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 30 0.00 2.52 BC 6 2.52 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 12 D 5 p 1113X6 C T 03X4B 1113X6(E5) A iv _ HB 5"13 =3X3 E F G=2X4 SEAT PLATE REQ. �--- 1'11"15 —� �-- 2'0"11 11 "5 _ ' �- 3' -{ Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Left bottom chord exposed to wind. Additional Notes Negative reaction(s) of -649# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.107 G 280 36 VERT(CL): 0.186 G 162 24 HORZ(LL): -0.064 D - - HORZ(TL): 0.110 D Creep Factor: 2.0 Max TC CSI: 0.650 Max BC CSI: 0.088 Max Web CSI: 0.165 Wgt: 18.2lbs VIEW Ver: 19.01.00A.0618.15 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL G 1034 /- /- /917 /456 /60 E - /-68 /- /22, /54 /- D - /-649 /- /282 /600 A Wind reactions based on MWFRS G Brg Width = 8.0 Min Req = 8.0 E Brg Width =1.5 Min Req = - D' Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 313 - 379 C - D 231 - 262 B-C 177 -216 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-G 222 -81 F-E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. G - C 955 - 940 G - F 1011 - 956 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TOO to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkVieW Dr guidelines of the Building Component Safety Information (BBC[) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvnnht 0 2016 A-1 Rnnf Tn,.acac - RenrMuainn of this dnannant, in anv fnrn. A nrohihited withad the written nernic'nn of A-1 Ratf Tno—s. 81433 u... t rUa5 r ype idly J2 JACK 2 1 UiUU4/LULU 4160 r Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use pudins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 34 0.00 2.87 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. C 1-- 2'107 f — — 2-1"8 ­4"�— 2,6"15 Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical exposed to wind pressure. Deflection meets L/360. Defl/CSI Criteria PP Deflection in loc Udefl VERT(LL): -0.002 B 999 VERT(CL): 0.002 B 999 HORZ(LL):-0.002 B - HORZ(TL): 0.002 B - Creep Factor: 2.0 Max TC CSI: 0.679 Max BC CSI: 0.100 Max Web CSI: 0.568 Wgt: 18.2lbs VIEW Ver. 19.01.00A.0618.15 I 1 ♦ Maximum Reactions (Ibs) # Gravity Non -Gravity 60 Loc R+ / R- / Rh / Rw / U / RL 0 E 431 /- /- /386 /347 /- - D 57 /- P /29 P /92 - C 60 /- P /56 191 /244 Wind reactions based on MWFRS E Brg Width = 1.5 D Brg Width = 1.5 C Brg Width = 1.5 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- B 76 0 B- C 339 -196 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. E-D 139 -128 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B - E 618 -402 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering Q.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for arty Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the content of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage. Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and guidelines of the Building Component Safety Information (BBC[) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and;duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terns are as defined In TPI-1. CnovH.W 0 2016 A-1 Roof Tmcsaa - Renrndurlion of thin domiment. in env torn. Is cmhihitad ufirhnut tha written mmiaslon of A-1 Ronf Tni- Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job r 81433 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " I Russ I rUss I ype J12A JACK 12 5 F,-,- 0 3X4 B 1113X6(E5) A T m Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 47 0.00 .3.94 Apply puriins to any chords above or below fillers at 24" OC unless shown otherwise above. Ury h'ly UZ$/U4/14ULU 2 1 D III1.5X3 C HB 1'4"9 N 1 113X4 E SEAT PLATE REQ. 2' i 2'6"12 1 1'4"9 --{ 3'11"5- 1 4020 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udefl U# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.062 F 498 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.117 F 262 240 G 634 /- /- /500 /219 /135 FT/RT:10(0)/10(10) HORZ(LL): -0.034 D - - E - /-114 /- 165 /122 /- Plate Type(s): HORZ(TL): 0.065 D - - D - A117 A /42 /104 A WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.431 G Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.437 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.118 D ' Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. Wgt: 19.6 Ibs Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A - B 195 - 331 C - D 42 - 79 B - C 136 - 305 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-F 342 -68 F-E 0 0 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 729 -408 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkUeW Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. (`,nnwinht 9) 2016 A-1 Rmf Tnrcaac — R-raduntion of this der anent. in anv form. is nmhihhed wUhcvt thn written [wnnil;<Inn of A-1 Rmf Tniccac. 81433 r r YJA I r Ub5 1 ytJC J3 JACK Wfy I r-ty 16 1 U8/U4/LULU 3911 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NC13CLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 1113X6(E5) T' co 1 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 60 0.00 5.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 12 5 p SEAT PLATE REQ. C 1 2'6"12 -„ice 2'5"4 -� 5' mi 1 1 Code / Misc Criteria Defl/CSI Criteria I ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L� Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.081 F 379 3160 Loc R+ / R- / Rh / Rw / U / RL G 577 /- A /530 /277 /172 Rep Factors Used: Yes VERT(CL): 0.144 F 213 240 FT/RT:10(0)/10(10) HORZ(LL): -0.045 D - I - E - /-48 /- /22 /26 A PlateType(s): HORZ(TL): 0.080 D - �,- D 71 /-39 A /12 /100 A WAVE Creep Factor: 2.0 i Wind reactions based on MWFRS Max TC CSI: 0.438 G Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.439 I E Brg Width = 1.5 Min Req = - Max Web CSI: 0.092 D Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. Wgt: 22.4 Ibs Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.151 Chords Tens.Comp. Chords Tens. Comp. A - B 187 -265 C - D 27 -100 B - C 138 - 247 Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Left bottom chord exposed to wind. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNO' Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the l connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of th use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD at guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities a Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer Is Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. Cnnvdnht 0 2016 A-1 Rmf Tit-- R—rhiclinn of this dnmment. in anv fnrm. is nmhihitad withnut the written nenniacinn of A-1 Rmf Tmsces. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- F 270 - 73 F- E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 491 -403 EDGMENT" form. I, only Alpine fessional englneednE Manuel Martinez, P.E. / Building is the # 047182 'Do and any field he practices and 4620 ParkView Dr duties of the Truss IT the St Cloud, FL 34771 Job 81433 Truss I cuss t ype ury my J3A JACK 2 1 1 U61U41zuZu 4008 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 12 D 5 p 1111.5X3rf o3X4 B 1113X6(E5) A T i;o 1 F E 1113X3 SEAT PLATE REQ. 2' -{ Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 51 0.00 4.26 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. I- 2'6"12 1 1'8"6 -- I — 4'3"2 Code I Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.065 F 471 360 Loc R+ / R- / Rh / Rw / U / RL G 601 /- /- 1462 /197 /146 Rep Factors Used: Yes, VERT(CL): 0.125 F 244 240 FT/RT:10(0)/10(10) HORZ(LL): -0.036 D - - D 24 /-85 /- /31 180 /- Plate Type(s): HORZ(TL): 0.070 D - - E - /-87 /- /54 /93 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.508 G Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.438 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.120 E Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. Wgt: 21.0 Ibs Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A - B 195 - 342 C - D 19 - 87 B-C 136 -319 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- F 354 - 70 F- E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 710 - 398 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' torn. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering p.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineefin,c Manuel Martinez, RE. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. C ftht Q 2016 A-1 Rmf Tn,-- Re .dudim of thic d—rment. in env fnrrn. is nmhibited Wthmt the written nrrmlacim of A-1 Rmf 7ni uc. rrubb 81433 J3B rrusb Type JACK wl 2y II1y I utUu4/LULU 4315 Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP 2400f-2.OE Bot chord 2x4 SP #2 B1 2x4 SP 2400f-2.OE; Webs 2x6 SP #2 W3 2x4 SP 43; Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 28 0.00 2.29 BC 28 2.29 4.63 BC 5 4.63 5.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 0 1.Sx4G SEAT PLATE REQ. �-- 3'4` �{ 1 - 2'0.12 2-3.4 •'I i 5'0'1 �{ Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.217 K 202 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.401 K 109 240 J 1035 /- /- /829 /392 /172 FT/RT:10(0)/10(10) HORZ(LL): -0.122 E - �,- G - /-93 /- 141 /87 /- Plate Type(s): HORZ(TL): 0.226 E - i- F - /-428 /- /184 1382 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.408 J Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.656 G Brg Width = 1.5 Min Req = - Max Web CSI: 0.409 F Brg Width = 1.5 Min Req = - Bearing J is a rigid surface. Wgt: 35.0 Ibs Bearing J requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A - B 207 -434 D - E 28 -57 B - C 144 - 284 E - F 217 -169 C-D 104 -197 Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Negative reaction(s) of -428# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp I A : K 282 - 68 J -1 59 - 51 L-J 265 -55 H-G 0 0 Maximum Web Forces Per Ply (Ibs) i Webs Tens.Comp. Webs Tens. Comp. C - K 162 -181 1 - E 344 - 251 K-L 257 -199 1 - H 101 -114 D - J 585 -445 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering p.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of.the IRC, the IBC, local building code and TPI-1. The approval of the irDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD andthe practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C nvrinht W 201r A-1 Ronf T.,.-- Renrnd,01on of thL" doot-Ant. in anv form. Is nmhihitad without thn wrinnn nenninxinn of A-1 Rmf Tmcaea. I Job Truss 81433 J4 Truss Type Qty Ply MONO 2 1 1 08/04/2020 4157 Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL 15.00 Speed: 170 mph BOLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 58 0.00 4.87 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 1113X4(R) 12 R D C 1111.5X4 III3X6(R) f -- 4107 —{ Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical exposed to wind pressure. Deflection meets L/360. Right end vertical not exposed to wind pressure. Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): 0.001 A 999 36( VERT(CL): 0.001 A 999 24( HORZ(LL): -0.006 B - - HORZ(TL): 0.007 B - Creep Factor: 2.0 Max TC CSI: 0.667 Max BC CSI: 0.275 Max Web CSI: 0.471 Wgt: 37.8 Ibs VIEW Ven 19.01.00A.0618.15 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL D 274 /- /- /160 122 /335 B 217 A /- /106 /203 A C 100 A /- /133 /156 A Wind reactions based on MWFRS D Brg Width = 1.5 B Brg Width = 1.5 C ' Brg Width = 1.5 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A - B 83 -143 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. D - C 123 - 377 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-D 147 -223 B-C 0 0 A - C 456 -149 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (I.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn.c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. Convdnht Q 2016 A-1 Rnnf Tn-- Renrndnrtinn of ihi" domrment. in anv form. is nmhibifed withnre the written nermiecinn of A-1 Ronf Tm""ne. Job 81433 Truss AA Truss Type JACK Qty 4 08/04/2020 4011 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 1113X6(E5) I Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 69 0.00 5.79 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 1113X4 SEAT PLATE REQ. �— 2'1",5 --� 2'8"1 3'1"6 R 5'9"7 1 Code / Misc Criteria Deft/CSI Criteria I ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udefl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.093 F 344 360 Loc R+ / R- / Rh / Rw ! U / RL G 603 /- /- /433 /196 /190 Rep Factors Used: Yes VERT(CL): 0.181 F 176 240 FT/RT:10(0)/10(10) HORZ(LL): -0.050 D - I- E 19 /-30 /- /39 /35 !- Plate Type(s): HORZ(TL): 0.096 D - II D 105 /-16 /- /28 1126 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0. 517 G Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.517 E Brg Width = 1.5 Min Req = - D Brg Width = 1.5 Min Req = - Max Web CSI: 0.473 Bearing G is a rigid surface. Wgt: 25.2 Ibs Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver 19.01.00A.0618.15 I Chords Tens.Comp. Chords Tens. Comp. li A - B 206 - 390 C - D 39 -149 B - C 146 - 375 Wind Wind loads based on MWFRS with additional C&C member design. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONSCUSTOMER("BUYER") ACKNO' Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the l connector plates shall be used for the TDD to be valid. As a Truss Design Engineering p.e. Specialty Engineer), the seal on any TDD represents an acceptance of the responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of th use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD at guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities a Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer Is Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. C riaht C 201E A-1R"nfTntcsnn—Rnnrodudl-of thin dwiment. in anv form. in nrohihhnd withnut thn wdhan nnrmisninn M A-1 RonfTmcses. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-F 403 -74 F-E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 750 -437 EDGMENT" form. ), only Alpine fessional engineerin Manuel Martinez, P.E. Building is the # 047182 DD and any field he practices and 4620 ParkView Dr duties of the Truss )T the St Cloud, FL 34771 Job Truss 81483 1 J4G I russ I ype MONO ury rly 2 1 USfU4/LULU 4342 T 1 IO1.5x4 4'3"12 864 4 1 1 1'1"9--J--2' 431# 1,2-3'-� 27 93# Loading Criteria (per) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(LL): -0.001 B 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Varies by Ld C $'r:RT(CL): 0.002 B 999 240 D 614 /- /- P /410 P BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.001 B - - C 711 P /- P /644 P EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.001 B - - Wind reactions based on MWFRS Des Ld: 55.00 Mean Height: 25.00 It WAVE Creep Factor: 20. D Br Width = - Min Re 9 q = - NCBCLL: 10.00 TCDL: 5.0 sf P Max TC CSI: 0.504 C Brg Width = - Min Req = - Load Duration: 1.25 BCDL: 5.0 psf Max BC CSI: 0.639 Maximum Top Chord Forces Per Ply (Ibs) Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max Web CSI: 0.204 Chords Tens.Comp. C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 Wgt: 26.6 Ibs A - B 85 -101 GCpi: 0.18 Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 Maximum Bot Chord Forces Per Ply (Ibs) Lumber Chords Tens.Comp. Top chord 2x4 SP #2 D - C 54 -33 Bot chord 2x4 SP M-30 Webs 2x4 SP #3 Maximum Web Forces Per Ply (Ibs) Special Loads Webs Tens.Comp. Webs Tens. Comp. --(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) A - D 157 -198 B - C 244 -276 TC: From 93 plf at 0.00 to 93 plf at 4.31 A - C 22 - 33 BC: From 10 plf at 0.00 to 10 plf at 4.31 TC: 86 lb Conc. Load at 4.31 BC: 431 lb Conc. Load at 1.13 BC: 274 lb Conc. Load at 3.13 BC: 93 lb Conc. Load at 4.31 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 52 0.00 4.31 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (rDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering Q.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerinE Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 0471$2 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvdoht Q 2m16 A•1 Rnof Tn-- Renmdurlinn of thin dmirnont. in anv fnnn. in nmhihifad wilhout the written n—ninnion of A-1 Rod Tnrc .- Job I russ Truss Type Qty 'Ply 08/04/2020 81433 J5 1 JACK 10 1 6750 12 5 p III1.5X4 C -3X4 B 1113X6(E5)A HB 4'5"4 �I F III1.5X4 SEAT PLATE REQ. �2'� �-- 2'6"12 T Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCp): 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 7.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Left bottom chord exposed to wind. �;t 4'5'4 ,{ Defl/CSI Criteria I ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl Li# Gravity Non -Gravity VERT(LL): 0.150 F 204 360 Loc R+ / R- / Rh / Rw / U / RL G 621 /- P /568 /301 , /242 VERT(CL): 0.,168 F 183 240 HORZ(LL):-0.087 D - E 60 /- /- /123 /91 /- HORZ(TL): 0.100 D I- D 171 J- /- /72 /185 /- Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.596 G Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0. E Brg Width = 1.5 Min Req = - Max Web CSI: 0.107 07 D Brg Width =1.5 Min Req = - I Bearing G is a rigid surface. Wgt: 28.0 Ibs I Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. I A-B 181 -318 C-D 66 -152 B - C 146 -283 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A- F 302 - 80 F- E 0 0 i Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 492 -486 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNO Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the'I connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of th use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD at guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities a Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrioht Q 2016 A-1 Rnnf Tn.--- Renrnd-11nn of this dnnrment. in env form. is nrohibhed without thn written neonission of A-1 Rnnf Tmcses. DGMENT' form. only Alpine assional englneerin.c Manuel Martinez, P.E. Buildhe anyIs tfield # 047182 D and a practices and 4620 ParkView Dr uties of the Truss r the St Cloud, FL 34771 Job 814;33 Truss J5A Iruss type JACK ury rly 2 1 u01u1+11du1u 4014 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NC13CLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 4 SEAT PLATE REQ. �--- 2'1 "5 1 i-- 2'8"1 61"13 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP 2400f-2.0E Bot chord 2x4 SP 2400f-2.0E Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 8.82 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. u 1 1 8'9„14 t Code I Misc Criteria Deft/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udefl U# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.243 F 131 360 Loc R+ / R- / Rh / Rw / U / RL G 710 /- /- 1472 /257 /290 Rep Factors Used: Yes VERT(CL): 0.298 F 107 240 FT/RT:10(0)/10(10) HORZ(LL): -0.132 D - - E 100 /- /- 155 116 /- Plate Type(s): HORZ(TL): 0.147 D - - D 247 /- /- /101 /250 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.395 G Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.286 E Brg Width = 1.5 Min Req = - D Brg Width = 1.5 Min Req = - Max Web CSI: 0.109 Bearing G is a rigid surface. Wgt: 33.6 Ibs Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A-B 226 -318 C-D 91 -177 B - C 148 -298 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-F 299 -71 F-E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 548 - 592 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seat on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. r:nnvrinht 0 2016 A-1 Rnnf Tni. vc — R"nrndudinn of this dnntmnnt. in env form, is nmhihited wifhnut thn wrinnn ii—ircion of A-1 Rnof Tnissss. JOD 81433 I russ J5B Iuss type JACK Cary 2 08/04/2020 4320 F 111.& G SEAT PLATE REQ. 3'4' - i l^- 2-0.12 -+1 2,3.4'-' "9 -" 74-9 _'I 7V1 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP 2400f-2.0E Bot chord 2x4 SP #2 B1 2x4 SP 2400f-2.OE; Webs 2x6 SP #2 W2,W4 2x4 SP #3; Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 28 0.00 2.29 BC 28 2.29 4.63 BC 29 4.63 7.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Defl/CSI Criteria PP Deflection in loc Udefi VERT(LL): 0.177 K 232 VERT(CL): 0.346 K 118 HORZ(LL): -0.110 E - HORZ(TL): 0.210 E - Creep Factor: 2.0 Max TC CSI: 0.405 Max BC CSI: 0.430 Max Web CSI: 0.292 Wgt: 43.4 Ibs VIEW Ver. 19.01.00A.0618.15 I 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL 0 J 783 /- /- /565 /248 /242 G 57 P P /19 /1 /- F 106 /-86 P /46 /167 /- Wind reactions based on MWFRS J Brg Width = 8.0 Min Req = 1.5 G Big Width = 1.5 Min Req = - F Big Width = 1.5 Min Req = - Bearing J is a rigid surface. Bearing J requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 334 -401 D-E 24 -110 B - C 289 - 374 E - F 41 -139 C - D 208 - 303 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - K 378 - 212 J -1 44 - 38 L-J 347 -183 H-G 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. K - L 154 -164 J - D 405 - 531 K - C . 82 -151 I - E 223 -139 C-J 389 -108 I-H 73 -7 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TOD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any Too represents an acceptance of the professional engineed responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD andlthe practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. f:nmvrinht Q 2n1 6 A-1 Rnnf Tmssr-s - RenrndudAnn of this d-rn-t. in anv fnrrn. is ..MUM uflfhnuf thn writlnn nerrn1-1- of A-1 Rnnf Tni¢s Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job 81433 Truss J513 Truss Type JACK city jly 2 1 U61U4/Z000 6744 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " .I Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 7.00 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. �-- 2'0"12 -- n 75"1 i 4'6"15 7' 1 I Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udefl U# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.151 F 191 360 Loc R+ / R- / Rh / Rw / U / RL F 602 /- /- /551 /292 /242 Rep Factors Used: Yes VERT(CL): 0.133 F 218 240 FT/RT:10(0)/10(10) HORZ(LL):-0.088 D - - E 66 /- /- /134 /97 P Plate Type(s): HORZ(TL): 0.097 D - - D 179 P /- /80 1191 P WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.571 F Brg Width = 3.1 Min Req = 1.5 Max BC CSI: 0.584 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.106 D Brg Width = 1.5 Min Req = - Bearing F is a rigid surface. Wgt: 28.0 Ibs Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 A - B 173 - 323 C - D 69 -155 B - C 138 - 278 Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Left bottom chord exposed to wind. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-F 295 -75 F-E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 482 -479 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering ii.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn,c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Tmss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnvdaht0)2m1a A-1 Rnof TrILGSRS—Renrodurlion of this domrment. In env fnnn. Is nmhibdad withmit the written n iceinn of A-1 Roof Tnisnes jou I Fuss I russ I ype Uty I Fly US/U4/ZULU 81433 JACK 2 1 , 4005 ID 12 5 p N III1.5X4 C v -3X4 B 1113X6(E5)A HB 5'9"6 �I 1111.5X4 SEAT PLATE REQ. �2'— I 2-6.12 576 8'4"2 Loading Criteria (psfl Wind Criteria Code / Misc Criteria Defi/CSI Criteria I ♦ Maximum Reactions (Ibs) TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L)# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(LL): 0.252 F 121 360 Loc R+ / R- ! Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.309 F 99 240 G 677 /- /- /460 /233 /289 BCDL: 10.00 Risk Category:11 FT/RT:10(0)/10(10) HORZ(LL):-0.144 D - . D 232 /- /- /103 /241 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.160 D - - E 93 /- /- 151 /19 /- Des Ld: 55.00 eiei Mean Height: 25.00 ft WAVE Creep Factor: 2.0 I Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: P sf Max TC CSI: 0.436 G Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 psf " Max BC CSI: 0.322 D Brg Width = 1.5 Min Req = - S Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 P 9� � E Brg Width = 1.5 Min Req = - C&C Dist a: 3.00 ft Max Web CSI: 0.110 Bearing G is a rigid surface. Loc. from endwall: not in 4.50 f Wgt: 33.6 Ibs Bearing G requires a seat plate. GCpi: 0.18 1 11 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver: 19.01.00A.01618.15 I Chords Tens.Comp. Chords Tens. Comp. Lumber A - B 217 - 318 C - D 89 -181 Top chord 2x4 SP M-30 B - C 148 -293 Bot chord 2x4 SP M-30 i Webs 2x6 SP #2 Lt Slider: 2x4 SP #3; block length = 1.500' I Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Purlins In lieu of structural panels or rigid ceiling use purling A - F 295 -78 F - E 0 0 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) I Maximum Web Forces Per Ply (Ibs) BC 75 0.00 8.34 I Webs Tens.Comp. Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. C - F 527 -562 Wind Wind loads based on MWFRS with additional C&C member design **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be. valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. C nvriaht a) 2016 A-1 Rnaf Tnisses — RA— Lidinn of this d—ment. in env form. is nmhibitnd vAhout the written nermission of A-1 Roof Tmsses. r Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 Job 81433 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Truss R 4 I russ I ype EJAC Uty I-ly UtS/U4/ZU"LU 4 1 E I SEAT PLATE REQ. SEAT PLATE REQ. �'— 2' 5'4" I TV'12 I1'6"4 --� Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 9.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 9' 1 1 4035 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udefl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL):-0.004. B 999 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.010 B 999 240 H 577 /- /- /533 /268 /191 FT/RT: 1 0(0)/l 0(10) HORZ(LL): -0.003 D - - 1 510 /- /- /395 /277 /- Plate Type(s): HORZ(TL): 0.004 B - - F - /-16 /- /62 173 P WAVE Creep Factor: 2.0 E 33 /-69 P /15 /13 P Max TC CSI: 0.444 Wind reactions based on MWFRS Max BC CSI: 0.316 H Brg Width = 8.0 Min Req = 1.5 Max Web CSI: 0.164 1 Brg Width = 8.0 Min Req = 1.5 F Brg Width = 1.5 Min Req = - Wgt: 46.2 Ibs E Brg Width = 1.5 Min Req = - Bearings H & I are a rigid surface. VIEW Ver. 19.01.00A.0618.15 Bearings H & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 217 -167 C-D 87 -221 B-C 233 -113 D-E 13 -66 Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Left bottom chord exposed to wind. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-H 142 -160 G-F 0 0 H - G 50 - 308 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. H - C 303 -482 D - G 454 -405 C-G 319 -49 "WARNING' Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' forth. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TOD to be valid. As a Truss Design Engineering p.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C nvdnht M 2010 A-1 Rnnf Tnracea— Renroduntion of thin doarment. in anv fnnn. is nmhihited without the written narmiccion of A-1 Rnnf Tnraaec. 81433 rruaa J7A I[ use t ypu r,.tly irl MONO 1 19 I1 Uo/u4/LULU 3905 Loading Criteria (psp TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " I 1111.5X4 E 12 5 p @ 1.5X3 D -v 1111.5X3 C 3X4 B 1113X6(E5)A 1II1.5X3 GG III .5X3 H III1.5X3 I SEAT PLATE REQ. I-- 2` �. 9' ' Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: 11 EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 - Webs 2x4 SP #3 W1 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purling to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 71 0.00 9.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Left cantilever is exposed to wind Left bottom chord exposed to wind. Defl/CSI Criteria I ♦ Maximum Reactions (Ibs) PP Deflection in loc Udefl L/# Gravity Non -Gravity VERT(LL): 0.103 G 773 360 Loc R+ / R- / Rh / Rw / U / RL H 683 /- A /624 /333 /311 VERT(CL): 0.148 H 189 240 HORZ(LL):-0.053 D - I- F 170 /- A /225 /171 /- HORZ(TL): 0.088 E - I- E 191 /- !- /99 /153 /- Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.593 H Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.999 F Brg Width = 1.5 Min Req = - Max Web CSI: 0.128 I E Brg Width = 1.5 Min Req = - Bearing H is a rigid surface. Wgt: 44.8 Ibs Bearing H requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A - B 236 -359 C - D 76 -282 B-C 52 -184 D-E 73 -117 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-H 199 0 G-F 0 0 H - G 189 -285 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C-H 312 -458 E-F 0 0 D - G 370 - 245 I "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNO' Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the l connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal an any TDD represents an acceptance of the responsibility for the design of the single Truss depicted an the TOO only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of th use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TOO at guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities a Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer Is Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI-1. Cnnvriaht Q 2a16 A-1 Rmf Tnrsse-c — Rr .ch, 3inn of this d—unent. in env fnrm. is nmhihBnd without the written nernissim M A-1 Rmf Tnissm. .EDGMENT' form. ), only Alpine fessional engineerin Manuel Martinez, P.E. y Building Is the 'Do # 047182 and any field he practices and 4620 ParkView Dr duties of the Truss )T the St Cloud, FL 34771 Job I russ I russ I ype ury rty uo/u4/LULU 4323 • 81433 1 J7B I MONO 2 1 1 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 1015X4 ®3X4(R? SEAT PLATE REQ. �- 3'4" �{ F-- 2-0.12 1 23"4 'i' 4' i 8W Wind Criteria Code / Misc Criteria Wind Std: ASCE 7-10 Code: FBC 2017 RES Speed: 170 mph TPI Std: 2014 Enclosure: Closed Rep Factors Used: Yes Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Mean Height: 25.00 ft WAVE TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h , C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 W1,W2 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.500' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 28 0.00 2.29 BC 27 2.29 4.52 BC 46 4.48 8.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): 0.088 K 500 36( VERT(CL): 0.164 K 268 24( HORZ(LL): -0.048 F - - HORZ(TL): 0.088 F - - Creep Factor: 2.0 Max TC CSI: 0.539 Max BC CSI: 0.477 Max Web CSI: 0.992 Wgt: 61.6 Ibs VIEW Ver: 19.01.00A.0618.15 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL J 825 /- /- /593 /251 /205 G 24 /-85 A /64 /89 /- F 165 A A /75 /98 A Wind reactions based on MWFRS J Brg Width = 8.0 Min Req = 1.5 G Brg Width = 1.5 Min Req = - F Brg Width = 1.5 Min Req = - Bearing J is a rigid surface. Bearing J requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 331 -457 D - E 175 -272 B-C 268 -413 E-F 64 -117 C - D 269 - 397 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - K 436 -196 J - H 195 - 230 L-J 427 -191 1 - G 110 -133 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 57 -134 H - E 261 - 257 K - L 166 -169 E - G 204 -168 D- J 373 - 332 F- G 0 0 H-1 77 0 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"). GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkVew Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. C nvrinht 0 201E A-1 Rnnf Tru-- Renmdudinn of this dmiment. in env fnrm. lc nmhihifed vAthout the wrMAn nenniccinn of A-1 Rnnf Tru- I I uoo I yNc idly 1 fly UO/UN/LULU 81433 PB01 GABL 1 �1 a 4112 �— 2'6"8 "}' 11'37 2'6118 I 11 12 5 :5X6 III1.5X4 =5X6 C D E T 1'0"15 1 V n1 I.vi\v 1 111 I.V/\T I 1 1 III I.J/\J 01111 . 14'3" 1'0111 I I I 16'4"6 Loading Criteria (psi) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or'=PLF TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES I�� PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Slid: 2014 VERT(LL): -0.000 D 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.001 D 999 240 A 33 /- /- /17 /15 /32 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.000 H - II- B' 102 /- /- /54 /58 /- EXP: C : NA Plate Type(s): HORZ(TL): 0.001 H - I- G 33 !- /- /17 /15 /- Des Ld: 55.00 Mean Height: 25.00 ft WAVE B /-141 Creep Factor: 2..748 NCBCLL: 10.00 TCDL: 5.0 psf 1 1-157 Load Duration: 1.25 BCDL: 5.0 psf Max TIC CSI: 0 I 1 1-458 Spacing: 24.0 " MWFRS Parallel Dist: h to 2h Max BC CSI: 0.095 H /-157 C&C Dist a: 3.90 ft Max Web CSI: 0.154 F /-141 Loc. from endwall: not in 9.00 Wgt: 50.4 Ibs Wind reactions based on MWFRS GCpi: 0.18 A Brg Width = 8.5 Min Req = 1.5 Wind Duration: 1.60 VIEW Ver: 19.01.00A.0618.15 I B Brg Width = 170 Min Req = - Lumber I G Brg Width = 8.5 Min Req = 1.5 Top chord 2x4 SP #2 1 Bearings A, B, & G are a rigid surface. I Bot chord 2x4 SP #2 Maximum Top Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 I Chords Tens.Comp. Chords Tens. Comp. Plating Notes A - B 38 -36 D - E 46 -4 All plates are 2X4(A1) except as noted. B - C 75 - 63 E - F 75 - 63C - D 46 -4 F - G 16 -13 Purlins I In lieu of structural panels or rigid ceiling use pufins Maximum Bot Chord Forces Per Ply (Ibs) to laterally brace chords as follows: Chords Tens.Comp. Chords Tens. Comp. Chord Spacing(in oc) Start(ft) End(ft) e - J 44 -13 I - H 47 - 9 TC 24 1.48 12.77 BC 120 0.15 14.10 1-1 47 -9 H-F 44 -12 Apply puffins to any chords above or below fillers at 24" OC unless shown otherwise above. Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. Loading' Gable end supports 8" max rake overhang. Top chord must not be cut or notched. j C - J 199 -228 H - E 199 -228 iD-1 517 -650 Wind Wind loads based on MWFRS with additional C&C member design. ,I Additional Notes See STD DETAILS for gable wind bracing requirements. II I "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering p.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedric Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and ithe practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and, duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. i Cnnvrinht Q 2016 A-1 Rnnf Tnlcsr_a — Rannwhidlon of this dmiment. in anv fnnn. is nmhibiled Wthnut the wrinnn ne."nission of A-1 Ronf Tri—s. Job 81433 I russ Iruss type PB02 GABL 1ty I 1y I Ut$/U4/LULU 4115 1- 4'6"8 7'3"7 14'6"8 12 = 5X6 5 F,; -, - C //15X8(R) D B E A ^ ^ F H III 1.5X3 G III 1.5X4 1'0"11 1'0"11 14'3' — 16'4"6 Loading Criteria (psf) TCLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 2.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.90 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.003 H 999 36 VERT(CL): 0.005 H 999 24 HORZ(LL): 0.001 H - HORZ(TL): 0.002 H Creep Factor: 2.0 Max TC CSI: 0.683 Max BC CSI: 0.171 Max Web CSI: 0.117 Wgt: 51.8 Ibs VIEW Ver. 19.01.00A.0618.15 Lumber Top chord 2x4 SP 42 T2 2x4 SP M-30; Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 2X4(A1) except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 3.48 10.77 BC 120 0.15 14.10 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Gable end supports 8" max rake overhang. Top chord must not be cut or notched. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for gable wind bracing requirements. T to T 0 T T ♦ Maximum Reactions (Ibs), or `=PLF Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL A - /-33 /- /43 /40 /61 B• 104 /- /- /56 /52 /- F 65 /- /- /32 /59 A B /-144 H /-246 G /-408 Wind reactions based on MWFRS A Brg Width = 8.5 Min Req = 1.5 B Brg Width = 170 Min Req = - F Brg Width = 8.5 Min Req = 1.5 Bearings A, B, & F are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 81 -73 D - E 88 -77 B-C 116 -109 E -F 26 -25 C - D 116 -11 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-H 49 -12 G-E 72 -14 H-G 44 -13 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C - H 298 - 391 G - D 490 - 629 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' forth. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047162 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrinht C 201fi A-1 Rnnf T.,--- R—raduntinn of this dnatment. in anv form. N nmhihited vrithout the written nrrmi. Jnn of A-1 Ronf Tnineee. Job 81433 Truss Truss Type Oty I 08/04/2020 4109 PB03 GABL r 1 �1, �--- 2'6"12 + 1IT" 15 12 5 p :5X6 C Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 2.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 3.90 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 2X4(A1) except as noted Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TIC 24 1.50 12.75 BC 120 0.15 14.10 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code:FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Loading Gable end supports 8" max rake overhang. Top chord must not be cut or notched. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for gable wind bracing requirements. III 1.5X4 D 5 X 6 E 2'6"12 ---- 14'3" I 1'0"11 I I 16'4"6 Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or •=PLF PP Deflection in loc Udefl U# Gravity Non -Gravity VERT(LL): -0.001 D 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.001 D 999 240 A 32 !- /- /17 /15 /33 HORZ(LL): 0.001 H - B' 102 /- /- /54 /63 /- HORZ(TL): 0.001 H - I- G 32 /- /- /17 /15 /- Creep Factor: 2.0 J /-143 Max TC CSI: 0.742 1 /-491 Max BC CSI: 0.094 H /-142 Max Web CSI: 0.146 j Wind reactions based on MWFRS A Brg Width = 8.5 Min Req = 1.5 Wgt: 50.4 Ibs II B Brg Width = 170 Min Req = - G Brg Width = 8.5 Min Req = 1.5 VIEW Ver. 19.01.00A.0618.15 11 Bearings A, B, & G are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) lChords Tens.Comp. Chords Tens. Comp. i A - B 38 -37 D - E 46 -4 B - C 75 - 69 E - F 75 - 69 C-D 46 -4 F-G 16 -12 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. I B-J 49 -12 I-H 47 -9 J-1 47 -9 H-F 49 -11 I Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. Gables Tens. Comp. C - J 198 -247 H - E 198 -247 1 D - 1 515 - 648 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNON verify design parameters and read notes on this Truss Design Drawing (rDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TE connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the p. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for a responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD an[ guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities ani Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is t` Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C rioint a 2016 A-1 Roof Tniaaaa — Ramaduction of this dminiant. in any torn. is nrnhihited without the wdttan n—nlc inn of A-1 Roof Tni a a. EDGMENT" form. ), only Alpine �fessional engineerinc Manuel Martinez, P.E. 1 Building Is the # 047182 'Do and any field he practices and 4620 ParkView Dr duties of the Truss )T the St Cloud, FL 34771 Job Truss r 81433 VM02 I russ I ype VAL ury I rly 4 1 uo/u4/LULU 4336 Loading Criteria (psf) Wind Criteria TCLL: 30.00 Wind Std: ASCE 7-10 TCDL: 15.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 55.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 22 0.00 1.86 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. 8"6 +- 1'1 "15 --� 12 5 1 1'10"4 Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for valley details. T 20 Defi/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.003 B 999 36( VERT(CL): 0.006 B 999 24( HORZ(LL): 0.001 B - - HORZ(TL): 0.002 B - - Creep Factor: 2.0 Max TC CSI: 0.028 Max BC CSI: 0.081 Max Web CSI: 0.000 Wgt: 5.6 Ibs VIEW Ver. 19.01.00A.0618.15 ♦ Maximum Reactions (Ibs), or `=PLF Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL D' 112 /- /- /47 /17 114 Wind reactions based on MWFRS D Brg Width = 22.3 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-B 0 -18 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 59 -5 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerinc Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the ,# 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI.1. Cnnvdnht Q 2n1e A-1 Raat Tm. sa-a — Renmdurtinn of tNn d—ment. in anv fnnn. N nmhihftnd without the written nnnnicainn of A-1 Rnnf Tnv �. JVO I rU55 81433 VM04 i russ I ype VAL Ury 4 1 Ub1/U4/'LULU 4337 " 8"6 �--� 31"15 -{ 12 5 IC 3'10"4 3'3"12 1IAX6 I T co 1 Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or'=PLF TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udefl L/# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Std: 2014 VERT(I-Q: NA I Loc R+ / R- / Rh / Rw / U / RL F" 112 /- /- /56 /28 120 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): NA BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.004E - I- Wind reactions based on MWFRS Des EXa C : NA Plate Type(s): HORZ(TL): 0.008 E - I- F Brg Width = 46.3 Min ReqNCB= - Mean Height: 25.00 ft Height: WAVE Creep Factor: 2.0 Bearing A is a rigid surface. CLLd: 10.00 : 1 BCDL: 5.0 psf I Load Du on: Load Duration: 1.25 BCDL: 5.0 psf Max TC CSI: 0.202 � Maximum Top Chord Forces Per Ply (Ibs) Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.175 Chords Tens.Comp. Chords Tens., Comp. A - B 38 -82 B - C 0 -9 C&C Dist a: 3.00 ft Max Web CSI: 0.098 �I Loc. from endwall: not in 9.00 Wgt: 12.6 Ibs I GCpi: 0.18 Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 1 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Lumber i A- E 13 -15 E- D 0 0 Top chord 2x4 SP #2 I Bot chord 2x4 SP #2 Webs 2x4 SP #3 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Purlins B - E 220 -152 In lieu of structural panels or rigid ceiling use purlins I to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) i BC 46 0.00 3.86 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for valley details. "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOW Verify design parameters and read notes on this Truss Design Drawing (rDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TD connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the pr responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for ai responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building rode and TPI-1. The approval of the use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities anc Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is N Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. Cnnvrinht a) 201R A-1 Ronf T.,- -c - Rnnr d-Jlnn of thin Anmimnnt. In anv form. is nmhihitnd without the written nennit ion of A-1 Ronf Trimec. )GMENT' form. mly Alpine Isional engineerinc Manuel Martinez, P.E. uilding Is the # 047182 l and any field practices and 4620 ParkView Dr ties of the Truss the St Cloud, FL 34771 Job 81433 Truss Truss Type tdty Fry VM06 VAL 4 1 1 Ut$/U4/ZUZU 4338 .e% 8"6 5'1 "15 5'10"4 5'6"12 Loading Criteria (pst) TOLL: 30.00 TCDL: 15.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 55.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 70 0.00 5.86 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)110(10) Plate Type(s): WAVE Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See STD DETAILS for valley details. Defl/CSI Criteria PP Deflection in loc L/defi L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.014 C HORZ(TL): 0.026 C - Creep Factor: 2.0 Max TC CSI: 0.598 Max BC CSI: 0.439 Max Web CSI: 0.242 Wgt: 19.6 Ibs VIEW Ver: 19.01.00A.0618.15 ♦ Maximum Reactions (Ibs), or'=PLF Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL D` 112 /- /- /59 /32 /21 Wind reactions based on MWFRS D Brg Width = 70.3 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A - B 54 -107 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 201 -14 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B - C 301 - 220 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin.c Manuel Martinez, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 047182 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4620 ParkView Dr guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the St Cloud, FL 34771 Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrioht W 2016 A-1 Rmf Tmccr_v — Rannvludinn of this dmaimant. in anv form, is nrnhihitrd without thn written mrmissinn of A-1 Rmf Tmxsss. Job 81433 Truss Truss Type Qty PI VM07 VAL 12 h1 08/04/2020 s 4339 a"s s'o^7 C 6'8"12 r 518"10 r3"I if 1--'.I DF Loading Criteria (psq Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or'=PLF TCLL: 30.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udefl L%# Gravity Non -Gravity TCDL: 15.00 Speed: 170 mph TPI Sid: 2014 VERT(LL): 0.065E 999 360 Loc R+ / R- / Rh / Rw / U / RL F' 112 /- /- /59 /33 /22 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.122 E 576 240 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.022 C - Wind reactions based on MWFRS Des Ld: 55.00 EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.041 C - I- F Brg Width = 80.8 Min Req = - Mean Height: 25.00 ft WAVE Creep Factor: 2.0 Bearing A is a rigid surface. NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Max TC CSI: 0.616 Maximum Top Chord Forces Per Ply (Ibs) Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.481 Chords Tens.Comp. Chords Tens. Comp. A - B 59 -151 B - C 0 -26 C&C Dist a: 3.00 ft Max Web CSI: 0.247 Loc. from endwall: not in 9.00 Wgt: 22.4 Ibs I GCp!: 0.18 Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 I Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Lumber A- E 33 - 31 E- D 0 0 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Purlins B - E 396 -298 In lieu of structural panels or rigid ceiling use purlins I to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 81 0.00 6.73 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See STD DETAILS for valley details. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOW Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TD connector plates shall be used for the TDD to be valid. As a Truss Design Engineering p.e. Specialty Engineer), the seal on any TDD represents an acceptance of the pi responsibility for the design of the single Truss.depicted an the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for ai responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities an( Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is N Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C—daht 0 201fi A-1 Rmf Tniasev — Renmdurlinn of this d--ril. in env form. ix nmhihited u Hh.,t the wdhen nnrmi. Inn of A-1 Rmf Tnrecev. !DGMENT" form. only Alpine assional engineednE Manuel Martinez, P.E. Building Is the 047182 )D and any field a practices and 4620 ParkView Dr uties of the Truss r the St Cloud, FL 34771 3/16/2020 HIP/ KING JACK (TYPICAL) STDL 01.0 �A-1 ROOF = TRl156E9 A FLORIDA CORPORATION A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL. 34946 (772)409-1010 ATTACH END JACKS USING (4) 0.131" 0 TOE NAILS AT TOP CHORD & (3) 0.131" 0 TOE NAILS AT BOTTOM CHORD. ATTACH KING JACK USING (3) 0.131" 0 TOE NAILS AT TOP CHORD & 24" STRAP USING (6) 1 Od X IY' AT EACH END OF BOTTOM CHORD. ATTACH CORNER JACKS USING (2) 0.131" O TOE NAILS AT TOP & BOTTOM CHORDS (TYP). CORNERSET GENERAL SPECIFICATIONS: MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60, MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT. Manuel Martinez, P.E. # 047182 4620 ParkUew Dr FEBRUARY 17, 2017 1 ALTERNATE GABLE -END BRACING DETAILI I STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772 409-1010 1'-3'MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES 0 24' O.C. 2X6 DIAGONAL BRACE SPACED 4B' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). ' l PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \ BRACE AND THE TWO TRUSSES ON \ I EITHER SIDE AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. DIAGONAL BRACE TO BLOCKINGACH WITH I(5) - 10d COMMON WIRE NAILS. I END WALL CEILING SHEATHING STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: i METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE STRUCTURAL OF THE STRUCTURAL GABLE AND FASTEN PER THE I GABLE TRUSS FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' • X 3') NAILS SPACED 6' O.C. - FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-9B, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d ' (.131'X3') NAILS SPACED 6. O.C. (2X4 STUDS MINIMUM). STRUCTURAL GABLE TRUSf MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALL •• BRACING METHODS SHOWN ON PAGE 1 ARE VALID li AND ARE TO BE FASTENED TD THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. INLAYED STUD I AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO{PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLT. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED / STUDS. TRUSSES WITHOUT INLAYED STUDS ARE NOT ADDRESSED HERE. STANDARD GABLE / TRUSS Manuel Martinez, P.E. # 047182 4620 ParkView Dr 12/23/19 PIGGY -BACK TRUSS STDTL04.1 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 PIGGY -BACK DETAIL (TYPICAL) 180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. OR... 160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. IMPORTANT NOTE: TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS. MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C. DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA, STEEPLE, CHIMNEY OR DRAG STRUT LOADS. **REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE TRUSS SPECIFICATIONS.** PIGGY -BACK TRUSS. (REFER TO ACTUAL TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) OPTION NO. 1 - TEE-LOK 3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH 6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8" TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2 PLATES). OPTION NO.2 - APA RATED GUSSET: 8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d COMMON (0.1 13" x 2") NAILS PER GUSSET: 4 (EACH) AT CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION NO.3 - 2X4 VERTICAL WOOD SCAB: 2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE. ATTACH AT 8'-0" O.C. w/6 (EACH) 1 Od BOX NAILS (0.128" x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND 3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE STAGGERED 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION # 1: TEE-LOK MULTI -USE CONNECTION PLATE. OPTION #2: APA RATED GUSSET. OPTION #3: 2X4 VERT. SCAB. ATTACH EACH PURLIN TO TOP CHORD OF BASE TRUSS. PURLIN & CONNECTIONS BY OTHERS. BASE TRUSS. (REFER TO TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) PURLINS SPACED ACCORDING TO MAX. SPACING OF TOP CHORD OF BASE TRUSS. SPACING IS NOT TO EXCEED 24" O.C. & PURLINS TO BE LOCATED AT JOINT OF EACH BASE TRUSS. ** IMPORTANT NOTE ** THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES SPACED AT 24" O.C. OR LESS. Manuel Martinez, P.E. # 047182 4620 ParkView Dr JULY 17, 2017 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409.1010 VALLEY TRUSS (TYPICAL) SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6" O.C. GENERAL SPECIFICATIONS: i 1. NAIL SIZE = 3' X 0.1311" = 10d 2. WOOD SCREW =4.5" SDS25412 SIMPSON OR EQUIVALENT. 1 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL "A". 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS - 01. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. TRUSS, OR GIRDER l TRUSS 1 DETAIL A BASE TRUSSES -t tNu, GUMMVIV 3S, OR GIRDER TRUSS TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PERASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT= 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24" O,C. (BASE AND VALLEY) SYP TO THE ROOF W/ TWO MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. SIMPSON SDS25412 (1/4" X 4.5") OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. I I i i Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 FEBRUARY 5, 2018 1 TRUSSED VALLEY SET DETAIL STDTL06 �i GENERAL SPECIFICATIONS: �.i 1. NAIL SIZE = 3" X 0.131" =10d � 2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT s TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. A-1 ROOF TRUSSES 6. NAILING DONE PER NDS - 01. 4451 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. FORT PIERCE, FL 34946 772-409-1010 TRUSS, OR GIRDER TRUSS SECURI W/( VALLEY TRUSS y II I i II II II BASE TRUSSES (TYPICAL) IINi (NO SHEATHING) N.T.S. GABLE END, COMMON TRUSS, OR GIRDER P r2 VALLEYTRUSS TRUSS �\ (TYPICAL) SEE DETAIL "A" BELOW (TYP.) WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEANROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3112 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS #2 MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/ TWO MAX SPACING = 24" O.C. (BASE AND VALLEY) SIMPSON SDS25300 (1/4" X 3") MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 J U LY 17 2017 ' ' x %0 %w %0 ` V v " "" ' "" "" "" ' (HIGH WIND VELOCITY) STDTL07� A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ATTA( WIND DESIGN PER ASCE 7-98, ASCE 7-1 WIND DESIGN PER ASCE 7-10: 170 MPf MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE: MAX TOP CHORD TOTAL LOAD = 50 PSI MAX SPACING = 24" O.C. (BASE AND VA SUPPORTING TRUSSES DIRECTLY uivu rm Vr, L� r 1 R000=0 IVIUJ 1 0c DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' -10" ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. NON -BEVELED BOTTOM CHORD FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAYBE APPLIED TO THIS FACE UP TO A MAXIMUM 6/12 PITCH i NON -BEVELED BOTTOM CHORD 0 o�0 CLIP MUST BE APPLIEDITO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12/12 PITCH) I # 047182 4620 ParkView Dr St Cloud, FL 34771 FEBRUARY 17, 2017 STANDARD GABLE END DETAIL STDTL08 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409.1010 TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS W/lOd NAILS, 6' O.C. VERT STUD SECTION B-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. VERTICAL 2X6 SP OR SPF STUDPBRACE #2 DIAGONAL BRACE (4) - 16d NAILS16d NAILS SPACED 6' D.C. (2) lOd NAILSINTO 2X62X6 SP OR SPF #2 2X4 SP OR SPF #2L HORIZONTAL NAILED TO RTICALS SECTION A -A W/(4) - 10d NAILS DIAGONAL BRACE 4' - 0. O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 PROVIDE 2X4 BLOCKING BETWEEN Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED. * TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS (4) Bd NAILS MINIMUM, ROOF B 3X4= PLYWOOD SHEATHING TO 1 SHEATHING 2X4 STD SPF BLOCK * DIAGONAL BRACING ** L - BRACING REFER �I I V / rl/ REFER TO SECTION A -A TO SECTION B-B 24' MAX. NOTE:1. / 2. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. CONNECT (2) - 10d ON BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO 12' MAX. NAILS BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF - 4. SYSTEM. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR / BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. TRUSSES 12 24' O.C. S. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM / AT4'-0'D.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN 2X6 DIAGONAL BRACE WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT SPACED 48. O.C. ATTACHED THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE __, TO VERTICAL WITH (4) - STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TD SECTION A -A) ;" 16d NAILS, AND ATTACHED 7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240. TO BLOCKING WITH (5) - B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. OIAG. BRACE 10d NAILS. S. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10. 10d AND 16d NAILS ARE 0.131'X3.0' AND 0131'X3.5' COMMON WIRE NAILS HORIZONTAL BRACE RESPECTIVELY. (SEE SECTION A -A) 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4 SP #31 STUD 12" O.C. 3.8-10 5-6-11 6.6-11 11-1-13 2X4 SP #31 STUD 16" O.C. 3-3-10 4-9.12 6-6-11 9-10-15 2X4 SP #31 STUD 24" O.C. 2.8.6 3-11-3 5-4-12 8.1-2 2X4 SP 42 12" O.C. 3.10-15 5-6-11 6-6-11 11-8-14 2X4 SP 42 16" O.C. 3-6-11 4.9.12 6.6-11 10-8-0 2X4SP#2 24'O.C. 1 3.1-4 3.11-3 6-2-9 9.3.13 DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH 10d NAILS 6. O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER SOX OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. MAX MEAN ROOF HEIGHT = 30 FEET EXPOSURE B OR C ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS. END WALL Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 FEBRUARY 17, 2017 I WITH 2X BRACE ONLY L I STDTL09 NOTES: T—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T—BRACE / I —BRACE MUST COVER BOY OF WEB LENGTH. i THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2XB 10d 6' O.C. NOTE NAIL ALONG ENTIRE LENGTH OF T—BRACE / I —BRACE (ON TWO—PLY TRUSSES NAIL TO BOTH PLIES) NAILS SPACING BRACE ,I SIZE FOR ONE -PLY I TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 II 2X8 T—BRACE 2XB I —BRACE BRACE it SIZE FOR TWO-PLY TRUSS SPECIFIEDI CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 �i 2X4 T—BRACE 2X4 [—BRACE 2X6 12X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE I 2X8 I —BRACE T—BRACE / I —BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. i I NAILSI NAILS i WEB I NAILS WEB I I -BRACE T-BRACE SECTION DETAIL %nuel Martinez, P.E. # 047182 4620 ParkVieW Dr FEBRUARY 17, 2017 1 LATERAL BRACING RECOMMENDATIONS I STDTL10 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET ALONG A FLOOR TRUSS. NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW. 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE 772-409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE METAL FRAMING ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) ANCHOR TO ATTACH WEB WITH (3) - 10d SCAB WITH (3) - 10d TO TOP CHORD NAILS (0.131' X 3') NAILS (0.131' X 3'). r ATTACH TO VERTICAL - I BWITH LS )Od (01313X 3' NAILS BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK USE METAL FRAMING - ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - 10d TO BOTTOM CHORD NAILS (0131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - Sod NAILS (0.131' X 3') IN EACH CHORD ATTACH TO VERTICAL SCAB WITH (3) - 10d NAILS (0.131' X 3') TRUSS 21 6 4' - D' WALL STRONGBACK (TYPICAL SPLICE) (BY OTHERS) ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0.216' DIA.) INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE DRYWALL TYPE SCREWS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) Manuel Martinez, P.E. # 047182 4620 ParkView Dr FEBRUARY 17, 2017 LATERAL TOE -NAIL DETAIL STDTLI I + _. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE. FL 34946 772.409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45°; WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE,WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. I TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 BB.D 80.6 69.9 68.4 59.7 o .135 93.5 85.6 74.2 72.6 63.4 J .162 108.8 99.6 86.4 84.5 73.8 ri .128 74.2 67.9 58.9 57.6 50.3 c� .131 75.9 69.5 60.3 59.0 51.1 Z 0 .148 81.4 74.5 64.6 63.2 52.5 in N IM VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 115: 3 (NAILS) X 845 (LB/NAIL) X 1.15 (DOL) = 2915 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30° TO 60° 45.00° ANGLE MAY VARY FROM 30' TO 60° THIS DETAIL IS ',ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. I I I I I I SIDE VIEW (2X4) 3 NAILS NEAR SIDE NEAR SIDE NEAR SIDE I' 45.00' SIDE VIEW (2X6) 4 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30' TO 60' 45.000 P.E. # 047182 4620 ParkVew Dr f" • FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP OF HF SPF SPF-S 0 Z O J .131 59 46 32 30 20 .135 60 48 33 30 20 • Lr) ('7 .162 72 58 39 37 25 J _ F- Z LU J J Z JO Lo N .128 54 42 28 27 19 .131 55 43 29 28 19 .148 62 48 34 31 21 Q Z � .120 51 39 27 26 17 Z O .128 49 38 26 25 17 131 51 39 27 26 17 M .148 57 44 - 31 1 28 20 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE FOR WIND DOL OF 1.33: 3 (NAILS) X 37 (LB/NAIL) X 1.33 (DOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WIND DOL OF 1.60: 3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. +++ USE (3) TOE -NAILS ON 2X4 BEARING WALL +:s USE (4) TOE -NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S, )E TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY IL NAIL NAIL ""- Duel Martinez, P.E. # 047182 SIDE VIEW END VIEW 4620 ParkView Dr St Cloud, FL 34771 FEBRUARY 5, 2016 TYP 2x2 NAILER ATTACHMENT I I STDTL13 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 "I.0X4 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load,;,170 mph, ASCE 7-10, 29'-0" Mean Height, Exp.! B, C or D. I Manuel Martinez, P.E. # 047182 4620 ParkVew Dr St Cloud, FL 34771 April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS STDTL14 A-1 ROOF'TRUSSES 4451 ST-LUCIE.BLVD, FORT PIERCE, FL 34946 772-409A,Q10 (4) 12d TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT GIRDER 12 VARIES [:�:� (4) 12d MAX 30" (2'-6") 2x6 #2 SP (Both Faces) 24" O.C. SIMPSON H5 Manuel Martinez, P.E. # 047182 4620 ParkView Dr St Cloud, FL 34771 FEBRUARY 17, 2017 I STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTL15 DAMAGED OR MISSING CHORD SPLICE PLATES A-i ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409.1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK X (INCHES) MAXIMUM FORCE!(LBS) 15% LOAD DURATION SP DF SPF HF 2X4 2X6 2X4 2X6 2X4 1 2X6 2X4 2X6 2X4 2X6 20 30 24' 1706 2559 1561 12342 1320 1980 1352 2028 26 39 30' 2194 3291 2007 13011 1697 2546 1738 2608 32 48 36' 2681 4022 2454 1,3681 2074 3111 2125 3187 38 57 42' 3169 4754 2900 14350 2451 3677 2511 3767 44 66 Q. 3657 5485 3346 5019 i 2829 4243 2898 4347 • DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR .2X41 THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 3'). STAGGER NAIL, SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C I I I i BREAK •10d NAILS NEAR SIDE + 10d NAILS FAR SIDE 6' MIN I THE LOCATION OF THE BREAK MUST BE GREATER THE REQUIRED X DIMENSION FROM ANY PERIMETER AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT DO NOT USE REPAIR FOR JOINT SPLICES 1 NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. S. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. 4 TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THAN OR EQUAL TO BREAK OR HEEL JOINT (SEE SKETCH ABOVE). Manuel Martinez, P.E. # 047182 4620 ParkView Dr F FEBRUARY 17, 2017 I SCAB APPLIED OVERHANGS I STDTL16 F- X1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TRUSS CRITERIA: LOADING: 40-10-0-10 DURATION FACTOR: 115 SPACING: 24' O.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION NOTES: 1. ATTACH 2X_SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' DIA. X 3') SPACED S' O.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' D.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES Manuel Martinez, P.E. # 047182 4620 ParkView Dr