HomeMy WebLinkAboutBuilding PlansLOADCENTER RATED VOLTAGE 1201240V-1 RATED AMPS 60 DEMAND KVA 5.1 BRANCH DEVICES Plug —on Phase/3W/SN LOCATION MOUNTING Pavilion Surface DESCRIPTION BREAKER CIR NUM. BREAKER DESCRIPTION TRIP POLE POLE TRIP Receptacles — GFI 20 1 1 2 1 20 Lighting/Receptacles Receptacles — GFI 20 1 3 4 1 20 Lighting/Receptacles Receptacles — GFI 20 1 5 6 1 20 Grill Hood and Light Grill 20 1 7 8 1 20 TV Outlet U.C. Refrigerator 20 1 9 10 1 20 Fire Place Spare 20 1 11 12 1 20 Spare 13 14 15 16 I I I I I I I I I I I I I ---------------------------------��I Electrical Plan SCALE: 1/4" = 1'-0" t O p 1-1/2" PVC CONDUIT TO EXISTING POOL PANEL , WITH ((2)) — J6 THWN CU LINE) O (1) — #6 THWN CU ,LINE) ^1 (1 — J10 THWN CU (BOND) U 3 a Revisions: t h �I Date�41 0910912020 Job No: 5 1 MARLEY Drawn By: TMM Designed By: TMM [EP Sheet PAUL WELCH INC. _ MECHANICAL ELECTRICAL CIVIL ENGINEERING1984 S.W. BILTMORE ST. SUITE 11114E1 PORT SAINT LUCIE, FL. 34984PHON_ E—MAIL FAX(772) 785-9858 PWELCHINC®AOL.COM (772) 785-9933 PAUL WELCH, P.E. FL. REG. NO. 29945 '�0' 0 Of ` 1 Sheet I DESIGN PARAMETERS: Florida Building Code (6TH EDITION 2017) .Florida Residential Code (6TH EDITION 2017) Florida Mechanical Code (6TH EDITION 2017) Florida Fuel Gas Code (6TH EDITION 2017) 2014 National Electric Code 2017 Florida Accessibility Code Building Design: 0 Utilimate Wind Speed: 1 Nominal Design Wind Speed: 1 Building Risk Category: II Wind Importance/Use Factor: 1 Building Height: 1 Roof Overhang: 1 Roof Pitch: 4 Exposure: C BEAM SCHEDULE BEAU LDAGT li f SAFE GRAVITY LOAD APPLIED GRAVITY LOAD NOTES B-1 21'-8" 6x72 LUMBER 5,093 5,093 - B-2 II'-0" 6x72 LUMBER 10,036 5,924 - B-3 21'-8" 6x 12 LUMBER 5,0093 5,093 - B-4 11'-0" 6x72 LUMBER 10,036 5,924 - SCOPE OF WORK CONSTRUCT NEW PAVILION PER PLANS 2017NOTE. MECHANICALALL RUCTCODI ON E AND STHEONEC (NFMPLY I A 70) 2014TH THE FBC 1 E7(6D TIONED/TION), AND THE FBC 17 RESIDENTIAL, NOTES' THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ETC. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, SPECIFICATIONS, ETC. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE FBC 2017 EDITION Product A roval Submittal Affidavit PERMIT j I BUILDING ADDRESS: PRODUCT MODEL } MANUFACTURER ATTACHMENT METHOD TYPE, SIZE, SPACING k BUILDING PRODUCT EMBEDMENT k STIFFENER ETC. DESIGN DESIGN PRESSURE PRESSURE ROOFING NOAJ BERMUDA ENTEGRA ROOF TILE, LLC TILE FASTENER: (2) 110d RING SHANK NAILS -62.8 -108.5 16-0112.07 CONCRETE THROUGH NAIL HOLES, 1/4' MINIMUM FLAT ROOF PENETRATION THROUGH PLYWOOD. ALL FASTENERS EXP. DATE TO BE CORROSION RESISTANT. FASTENERS SHALL BE 0610712021 TILE INSTALLED A MINIMUM OF 2 1/2' FROM HEAD OF TILE. INSTALL WITH A 4" TILE HEADLAP. OR DAP FOAM, NOA 16-0421.03 UNDERLAYMENT FL/ POLYGLASS POLYGLASS INSTALL ONE PLY WITH A MINIMUM 3` SIDE LAP FL5259-R30 100 SERIES AND 6' END LAP. PLACE FIRST COURSE PARALLEL TO EAVE. ROLL MEMBRANEMAXIMUM FOR POLYSTTCK TU REMOVE RELEASE MBRANE AS fT S APPLIED. PLUS 1 HAVE REVIEWED HE ABOVE PRODUCT APPROVAL INFORMATION AND APPROVE IT. NAME: PAUL WELCH P.E., CERTIFICATION NUMBER: 29945 12 North Elevation SCALE: 1/4" = 1'-0" South Elevation SCALE: 1/4" = 1'-0" "L 6'-9" +11'-0" TOP OF BEAM 0"-0" FINISH FLOOR 24'-8" 22'-6" 6'-4" 6'-9. West Elevation SCALE: 1/4" = 1'-0" East Elevation SCALE: 1/4" = 1'-0 f-\TFF----- - --,- - - - - - - -- t - - - - - - - - I I T/7 , , I B-3 GRILL & U. / \ HOOD RE . FP \ \GRILLING AREA \ � / o v M � DINING, m / o \ / N \ o I � "Revisions: f Date:0910912020 y Job No: Floor Plan MARLEY SCALE: 1/4" = 1'-0" Drawn By: TMM � Square Footage Designed By: TMM Pavilion 248 Sq1Ft SealN Sheet PAUL WELCH INC. f MECHANICAL ELECTRICAL CIVIL ENGINEERING ,_ 1 Total Area 248 Sq1Ft. 1984 S.W. BILTMORE ST. SUITE ff714 PORT SAINT LUCIE, FL. 34054 - PHONE E-MAIL FAX (772) 785-9888 WELCH. LCHINC®A L.CQN0. 299) 785-9933 .. - SrP PAUL l -2020 Of 2 Sheets 1 12 2 1 f 4 2 s TOP OF BEAM 12 CEILING— BEAM- i '-6" ix6 T&G CEILING USE SYP OR CYPRESS 6x 12 BEAM TRUSS TO BEAM — ANCHOR EACH TRUSS TO BEAM WITH APPROVED TRUSS STRAP (SEE TRUSS CONNECTOR SCHEDULE) EXTERIOR/WALL- 3/4- STUCCO FINISH ON METAL LATH ON WALL- 1/2- CDX PLYWOOD 2X6 FRAME WALL WITH SPF STUD GRADE " SHEATHING, NAILED WITH STUDS AT 16" OC. WITH DOUBLE TOP PLATE ANCHORED 8d NAILS O 4" O.C. WITH SIMPSON STUD PLATE TTE TSP O 16' O.C. Pu.= 1, 15/ WALL TO FTG— STUD AND 2X6 P.T. SILL PLATE ANCHORED WITH SIMPSON STUD PLATE TIE SPH6 O 16" O.C. Pu.-1,2401 2X6 P.T. SILL PLATE ANCHORED TO FOUNDATION WITH SIMPSON MUDSILL ANCHOR MAS O 487 O.C. Pu.-1,005/ TRUSS CONNECTOR SCHEDULE TRUSS ID BEARING POINT TRUSS ACTUAL CONNECTOR CONNECTOR FASTENERS NOTES UPLIFT ID UPLIFT DESIGN (9)-10d x 1 i12" CJ1 7 1,022 (1)—H10A 1,140 TO TRUSSES i PLY (9)-10d x i i12" TO BEAMS ALL OTHERS AT (9)-10d x 1 i12" FRAME BEARING LESS EACH <1,000# (l)—H10A 1,140 TO TRUSSES 1 PLY THAN 1,000# (9)-10d x 1 i12" TO BEAMS (9)—.1Od x 1 112" Al, A2 EACH 1,022 (I)—H10A-2 1,245 TO TRUSSES 2 PLY (9)-10d x 1 i12" TO BEAMS TRUSS CO. KOST TRUSS LAYOUT DATE 08-31-2020 CUT SHEET DATE 08-31-2020 TRUSS NOTES' NOTE: ALL STRAPPING TO BE SIMPSONSTRONG TIE 'AS SPECIFIED S E IED 1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANYS.ENGINEER 2) CONTRACTOR TO PROVIDE PAUL WELCH, INC. AND BUILDING DEPARTMENT WITH ENGINEERED TRUSS DRAWINGS BEFORE INSTALLING TRUSSES. 3) CONTRACTOR TO VERIFY ALL EXISTING ROOF CONDITIONS AND DIMENSIONS BEFORE ORDERING, AND INSTALLING TRUSSES. 4) TRUSS ITO TRUSS CONNECTIONS TO BE PROVIDED BY TRUSS COMPANY. 5) SEE TRUSS CONNECTOR SCHEDULE FOR TRUSS TO BEAM CONNECTIONS. 1 TOP/GR T �{ 12• t FOOTER— t 18" 12" HIGH X 12" WIDE POURED CONCRETE INTEGRAL FOOTING WITH (i)-#50 CONTINUOUS E Section at Wall Not To Scale FLAT ROOCEMENT TILE ROOF ON 30# FELT PAPER, TIN TAGGED TO 5/8" CDX PLYWOOD SHEATHING 24'-8" NAILED WITH 8D NAILS AT 6" O.C. PERIMETER SHEETS, REMAINING SHEETS 6" O.C. AT EDGES & 6" O.C. IN FIELD TO ENGINEERED WOOD TRUSSES AT 24" O.C. DO NOT COUNTERSINK. 1 22 -6 SEE CONNECTOR SCHEDULE FOR TRUSS ANCHORS. " " 6'-9" 6'-4" 6'-9" EAVE 2X4 TRUSS TAIL WITH 1X2 P.T. DRIP EASE ON 12 2X6 CEDAR FASCIA WITHGALVANIZED DRiP CAR 4 r 4-- r 0 0 I , rANCHOR o o + TOP OF BEAM12J LIN G BEAM i _6CYPRESS F-26x12 BEAM 314" STUCCO FINISH Br M- 04 F 2TRAVERTINE MARBLE ON TYPICAL H TR70 BEAM WITH "SIMPSON" WELL COMPACTED CLEANANE (SEE TRUSS CONNECTOR SCHEDULE SAND BASE. (95% DENSITY) BEAM TO COLUMN — ANCHOR EACH BEAM TO COLUMN WITH SIMPSON" ECCLQ BUCKET, TYPICAL AT ALL FOUR CORNERS F_2 COLUMN—T 10" X 10" CONCRETE BLOCK COLUMN WITH POURED CORE o o ° WITH (4)-#5 VERTICAL RODS 'N o o ° r o o CAPSTONE ° L J L J COLUMN 16" X i6" CONCRETE BLOCK COLUMN WITH POURED CORE F-i F-1 WITH (4)-#5 VERTICAL RODS CULTURED STONE VENEER 19'-10" FLOOR TRAVERTINE MARBLE ON 22'-6" WELL COMPACTED CLEAN SAND BASE. (95% DENSITY) FINISH GRADE EXPANSION JOINT Foundation Plan FOOTING— SCALE: 1/4° __ 1• D•• 12" HiGH X 36" SQUARE POURED CONCRETE o c PAD FOOTING WITH (3)-#50 BOTH WAYS, BOTTOM. F-1 - 12" HIGH X 36" SQUARE POURED CONCRETE PAD FOOTING WITH (3)-150 BOTH WAYS, BOTTOM. Se c t' e n at Column. F-2 - 12" HIGH X 12" WIDE POURED CONCRETE Not To Scale INTEGRAL FOOTING WITH (1)-150 CONTINUOUS ti Seal PAUL WELCH INC. MECHANICAL ELECTRICAL CIVft ENGINEERING. _ 1984 S.W. BILTMORE ST. RITE #114 PORT SAINT LUCIE, FL. 44984 ; PHONE E-MAIL FAX _ (772) 785-9888 PWELCHINCOAOL-Q& (772) 785-9933. - JEI" i �� PAUL WELCH, P.E. FL. REq: NO. 29945 Revisions: Fo09/09/2020 Job No: MARLEY Drawn By: TMM' Designed By: TMM (Sheet 2 Sheets °°