Loading...
HomeMy WebLinkAboutIKO Product Approval & Install Instructions Florida Building Code Online Business & ProfessionalRegulation BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search Florid or Product Approval R USER:Public User Product Aooroval Menu>Product or Aoolication Search>Application List>Application Detail �OFFICEOFTHE FL# FL30310-RO SECRETARY Application Type New Code Version 2017 Application Status Approved Comments Archived p Product Manufacturer IKO Industries Ltd Address/Phone/Email 40 Hansen Road South Brampton, NON-US L6W 3H4 (905)457-2880 Ext4581 william.liu@iko.com Authorized Signature William Liu william.liu@iko.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity FM Approvals- QA Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. 0 Validation Checklist- Hardcopy Received Certificate of Independence FL30310 RO COI IK019002 2017 FBC Eval Shingles.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D 3018 1990 ASTM D 3161 2016 ASTM D 3462 2010 ASTM E 108 2011 TAS 100 1995 TAS 107 1995 file:///C/Users/moore/OneDrive/Documents/iko.html[9/18/2020 8:10:56 AM] Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/15/2019 Date Validated 08/16/2019 Date Pending FBC Approval 08/23/2019 Date Approved 10/15/2019 Date Revised 10/16/2019 Summary of Products FL# Model, Number or Name Description 30310.1 IKO Shingles ASTM D 3161, Class F asphalt shingles, hip and ridge shingle, starter strip&shingle strip Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL30310 RO II IK019002 2017 FBC Eval Shingles.pdf Approved for use outside HVHZ: Yes Verified By: Zachary R. Priest PE-74021 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See evaluation report for limits of use. FL30310 RO AE IK019002 2017 FBC Eval Shingles.pddf Created by Independent Third Party: Yes 0 Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® U, 1 ® 9 Credil Card Safe file:///C/Users/moore/OneDrive/Documents/iko.html[9/18/202O 8:10:56 AM] Certificate of Authorization No. 29824 CREEK 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, L.LC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: IKO INDUSTRIES, LTD Issued August 15, 2019 40 Hansen Rd S Branpton, ON L6W 31-14 Canada (905)457-2880 Manufacturing Plants: Calgary,Alberta Hawkesbury, Ontario Hillsboro,TX Kankakee, IL Sumas,WA Sylacauga,AL Toronto,Ontario Wilmington, DE Quality Assurance: FM Approvals(QUA1860) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.5.1, 1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Entity Report No. Standard Year FM Approvals(TST1867) 3036971 FM 4475 2010 FM Approvals(TST1867) 3040947 FM 4475 2010 ASTM E 108 2011 FM Approvals(TST1867) 3041689 FM 4475 2010 FM Approvals(TST1867) 3044376 FM 4475 2010 FM Approvals(TST1867) 3045254 FM 4475 2010 FM Approvals(TST1867) 3046191 FM 4475 2010 PRI Construction Materials Technologies(TST5878) IKO-050-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-051-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-053-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-067-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-071-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-072-02-02 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-076-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-077-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-088-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-095-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-096-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-099-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-100-02-01 TAS 107 1995 PRI Construction Materials Technologies(TST5878) I KO-1 14-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-115-02-01 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-120-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-121-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-123-02-01 ASTM D 3161 2016 1KO19002 FL30310 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. NDUSTIES,LTD CREEK IKO IAssphaltShingles F4JTECHNICAL SERVICES, LLC Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) IKO-125-02-01 TAS 107 1995 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-126-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-127-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-128-02-01 TAS 107 1995 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-129-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-130-02-01 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-131-02-01 TAS 107 1995 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-140-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-148-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-153-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-171-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-171-02-02 TAS 107 1995 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-171-02-03 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-198-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-198-02-02 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-198-02-03 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-199-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-199-02-02 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-199-02-03 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-201-02-01 ASTM D 3462 2010A ASTM E 108 2011 ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) IKO-201-02-02 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-201-02-07 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-202-02-01 ASTM D 3462 2010A ASTM E 108 2011 ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) IKO-202-02-02 TAS 107 1995 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-202-02-07 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-203-02-01 ASTM D 3462 2010A ASTM E 108 2011 ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) IKO-203-02-02 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-203-02-07 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-205-02-01 ASTM D 3462 2010A ASTM E 108 2011 ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) IKO-205-02-02 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-205-02-07 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-206-02-01 ASTM D 3462 2010A ASTM E 108 2011 ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) IKO-206-02-02 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-206-02-07 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-208-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-217-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-218-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) 476T0002 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) 476T0003 TAS 100 1995 PRI Construction Materials Technologies(TST5878) 476T0004 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) 476T0039 ASTM D 3462 2010A ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) 476T0040 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) 476T0041 TAS 100 1995 PRI Construction Materials Technologies(TST5878) 476T0042 ASTM D 3462 2010A ASTM D 3018 1990(R94)E1 IKO19002 FL30310 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK IKO INDUSTRIES,LTD F� Asphalt Shingles TECHNICAL SERVICES, LLC Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) 476T0043 TAS 100 1995 PRI Construction Materials Technologies(TST5878) 476T0044 ASTM D 3462 2010A ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) 476T0045 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) 476T0046 TAS 100 1995 PRODUCT DESCRIPTION ArmourshakeTM 18-1/2" x 37-3/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Sumas) architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Royal Estate M 13-1/4" x 40", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Toronto) architectural asphalt shingle surfaced with granules complying with ASTM D 3462. DynastyTM 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Calgary, Hawkesbury, architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Kankakee&Sumas) Shingles manufactured in Calgary and Sumas shall be used in the non-HVHZ only. NordiCM 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Kankakee) architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Cambridge TM 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Calgary, Hawkesbury, architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Hillsboro, Kankakee, Shingles manufactured in Calgary and Toronto shall be used in the non-HVHZ only. Sumas, Sylacauga, Toronto&Wilmington) CRC Biltmore® 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Calgary, Hawkesbury, architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Kankakee,Sumas& Shingles manufactured in Calgary and Toronto shall be used in the non-HVHZ only. Toronto) CRC Superglass® 13-1/4" x 39-3/8", ASTM D 3161, Class F self-sealing, 3-tab asphalt shingle with (Calgary, Hawkesbury& fiberglass mat coated on both sides with asphalt and surfaced with granules complying Toronto) with ASTM D 3462. Shingles manufactured in Calgary and Toronto shall be used in the non-HVHZ only. Marathon M Plus AR 13-1/4" x 39-3/8", ASTM D 3161, Class F self-sealing, 3-tab asphalt shingle with (Calgary, Hawkesbury, fiberglass mat coated on both sides with asphalt and surfaced with granules complying Hillsboro, Kankakee, with ASTM D 3462. Shingles manufactured in Calgary, Sumas and Toronto shall be Sumas,Sylacauga& used in the non-HVHZ only. Toronto) Marathon TM 13-1/4" x 39-3/8", ASTM D 3161, Class F self-sealing, 3-tab asphalt shingle with (Sylacauga) fiberglass mat coated on both sides with asphalt and surfaced with granules complying with ASTM D 3462. Hip&RidgeTM 12 13-1/4" x 36", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt hip and (Kankakee&Sylacauga) ridge shingle surfaced with granules and perforated every 12-inches complying with ASTM D 3462. Armour Starter TM 13-1/4"x 39-3/8", ASTM D 3161, Class F fiberglass reinforced asphalt strip embedded (Sumas) with granules complying with ASTM D 3462. For use with ArmourshakeM shingles. Leading Edge PIusTM 7-7/8" x 40-7/8", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt (Hawkesbury) shingle strip surfaced with granules complying with ASTM D 3462. IK019002 FL30310 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK IKO INDUSTRIES,LTD Asphalt Shingles I TECHNICAL SERVICES, LLC INSTALLATION .... .._.........._._....._...........................T ..........................._.....---..........__._..._.... ------__................ ...................-_...._.................................._._..__ __..___._......__......__......._._.-......................._._.............__._...............__......._..... ArmourshakeTM ; Basic Wind Speed(V,�t) Max. 194 mph -- ...__....._._._......_....... -. --......_ _.---........-_-._.....----..............._............................._._.......__................._..._..........; (Sumas) Basic Wind Speed(Va >a..._....._Max. 150 m�?.....................__........._ _......__......_...._........_..__..__..._.........__..... ...........__.._..... ........_....__.._ .._............._._...._.............. ........ . Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. ............................................._..._......................_..__..._._......._....... .............................._.__.___._.._.......__........._.........................-__-..-..._..............._......................_........................................................_......_............. s Deck(Non-HVHZ): Solidl. .__..__...................__............__.................._......................... .. . --- Undedayment: i In accordance with FBC requirements. _.__.........__._..._ .. _..... _.._._......_....._._._.... _ ._...- .....__.._.__.._............_. _ .._..... .... i Min. slope: i 2:12 and in accordance with FBC requirements. Refer to i the manufacturer's application instructions when installing _..._shingles at Slopes greater than 21:12. _..._....._..................._....................._._..............._..._._._._....._...__._. .......................-.__........., Installation(HVHZ): Installed with 5-7/8 inch exposure in accordance with RAS i 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. ..._...._..............._.............._...._..__.....__.................._ �...__._.. .. _._. -........_._.__..............._............. _ ._.._.._..._._........._............................_....._............. ._.... .... Installation (Non-HVHZ): Installed with 5-7/8 inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or"6 Nail Pattern"detailed below. Standard Application Reou res S Nails,,'F;;steners Nall Line Alignment i i`�1-----+� --4�--- --=• - - `+ `Notches i Figure 1. ArmourshakeTM 5 Nail Pattern Non-HVHZ only) ....._._-......_.............__.._..._.............._....__._......._..__......._._._�._._._..._........__. �.._...._. Nailing- Steep Slopes/High Mnd .Areas Applications G-Zc-,qa jMrv-� 6 Naiisrf + .!<•, ,:... Nail Line Alignment ' 1t,r * ` Alignment Novvho-' r -- - - - ---=+r NotctlES Figure 2. ArmourshakeTM 6 Nail Pattern IKO19002 FL30310 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK IKO INDUSTRIES,LTD Asphalt Shingles TECHNICAL SERVICES, LLC ......_ _...__..__� . . .,. ......-.._.................................__...._..........�__..................................._.....__......_..�__..._.............._....._...__...................................._............_.._....._..._......__....___........._._........................................................., Royal Estate Basic Wind Speed�V,,,c): Max.. 194 mph. . ..... r_.........___................_................... ....._......._._........._._............................_....._..................._..._. -............................._: (Toronto) Basic Wind Speed Max. 150-mph__._......._...._.......__._......_.._.__..----......_...---._..._......__.__......_._._.�.._...__- _..__....... .--------- -.-.---- ......... _........ Deck(HVHZ): in accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. __......_..._.................._......._..._.._........_.._........_._....._.__...__..._.._...._... .__._....._.._._._._.._...._.._..__.._..........._................._............._........_....._......_................_..._-_..............._..................,._................ : Deck(Non-HVHZ): Solidly sheathed in accordance with FBC .................... .. . ........ i Underlayment _.__........._......_In accordance with FBC„requirements._._........._........_.._......_.._........__..__._.._....._...__............................ Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing Shingles at slopes greater than 21 12 _._._.._.-. . _.............�......_._......_.._.._..P.__9................_._._....._.._...._..........._...__:_._............_..._..............._......__.............._....._......._... i s Installation Installed with 5-7/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. i Shingles shall be attached using "6 Nail Pattern" detailed I below. _._�_....._._ _._.__..__...__._.._._.._._._......._..__._....._......._....._......................._.._._._........ Installation (Non-HVHZ): ; Installed with 5-7/8 in....._.... exposure in accordance with FBG requirements and manufacturer's published installation instructions. Shingles shall be attached using either'A Nail Pattern"or"6 Nail Pattern"detailed below. Standard Application i ie`i ill 4 Nails F 35tt! i A. Nails Figure 3. Royal Estate TM 4 Nail.._Pattern...anon-HVHZ_only�. .._._.._........_...._......._............__....._.._......_..._......_..._...__........__...._..........._........_.._................ Steep Slopel'High Wind Applications i Nail, I Figure 4. Royal EstateTM 6 Nail Pattern IK019002 FL30310 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK IKO INDUSTRIES,LTD Asphalt Shingles TECHNICAL SERVICES, LLC . ....................................... ........................................*.................------ ----------------------...................... .................. TM Dynasty Basic Wind Speed.( 4 mp h Basic................Wind............ .... .............. ................... ..................................................................... .......... Max. 150 mph Basic Wind Sp66d(Calgary(Non-HVHZ), U ........................ ................ .....------------------------------................ Hawkesbury,Kankakee& Deck(HVHZ): In accordance with FBC requirements; Sumas(Non-HVHZ)) Solidly sheathed min. 19132 in. plywood or wood plank for new construction; Min. 15/32 in, plywood existing 1 and construction. -----------.......... ......... ........................... .............................................. ................... ...................................iqly.,§tq!�t�ed in accordance with FBC requirements, 2-Deck(Non-Hy!gy, ............................................_ ................................. Nord!cT* Underlament. In accordance......with h F'B'­-C­ requirements.--"'-'*' .. . .........................-..................................... ........... - ................................................................................. (Kankakee) Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturers application instructions when installing Shingles at slopes greater than 2112. . ...........................— ...................................... ................... ...................................... Installation(HVHZ): Installed with 8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. ............................................ ........ ........................................................................................... Installation (Non-HVHZ): I Installed with 5-7/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern" "or 13 Nail Pattern"detailed below. .................................................................................................. ............. .............................................. ................................................................ Standard Application Requires 4 Nails/Fasteners 1/1"VI C.cjrri rn,,n Boni L------------I --------- ------------------------------------------------ ArmourZone M Figure 5. DynaStyT and NordiCT 4 Nail Pattern (non-HVHZ only ................................................................. ............. ........................... ................................. ------ .......................................................................... Steep Slope/High Wind Applications Requires 6 Nails/Fasteners ("nfnm,-n Ron.:! --- ---------- - ----------- ArmourZone aStyT M Figure 6. Dyn m and NoriCT d 6 Nail Pattern ....................................................................................................................- ..........- .......... ............................................................................................................................................ ................ IK019002 FL30310 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK IKO INDUSTRIES,LTD Asphalt Shingles Eii TECHNICAL SERVICES, LLC ......................................_..__....................................................._.._._...................................................._................__._.......................... ._.._.........._.........._......................................................_......_....._........................_....................__....................................................................._............... CambridgeTMBasic Wind Speed(Vwt)..........I Max..194 mph ...._...._......._..._.._.......__.......I........ _._....................._........_.................._......._..........................................._...........; (Calgary(Non-HVHZ), Basic Wind Speed SVa�a�:....._....Max. 1.50 mph_.............._ _.........__........................._...................._.........._........._..._......__.............._._.............. I Hawkesbury, Hillsboro, Deck(HVHZ): In accordance with FBC requirements; Kankakee, Sumas, Solidly sheathed min. 19/32 in. plywood or wood plank for Sylacauga,Toronto(Non- new construction; Min. 15/32 in. plywood existing HVHZ)&Wilmington) construction. ....._....._.. ._..._..._.............._..........__._................................. _..._......._.....__._...._._.__.............._..........._......_........_._..........._.._._....._.._-._.........._......._..................................................................._............... Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements. and _.........................._.........._................_..._..........___.._._.__..._,._......_................. _..._......_....................._..............................................._......_........ .. . ........ .............. _l!goerlayment: In accordance with FBC requirements. ............. I Min.slope: 2:12 and in accordance with FBC requirements. Refer to CRC BiltmoreTM the manufacturer's application instructions when installing (Calgary(Non-HVHZ), shingles__...... p.__._....__............._....._. ........................._................ Installation HVHZ : Installed with 5-7/8 in. exposure in accordance with RAS Sumas(Non-HVHZ)& 115 and manufacturer's published installation instructions. Toronto(Non-HVHZ)) Shingles shall be attached using "6 Nail Pattern" detailed below. ............__..........._..._.._..----._._..........._.. - _:.._....._.__......_._....----._.....__.... --._._...._...........__..._.__._..................._........... Installation (Non-HVHZ): Installed with 5-7/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail r Pattern"o "6 Nail Pattern"detailed below. F....._.................._................._.._......._....._._..........................._...._......._..__...._......................_._............._..._...._........._..-_....._.....__.._.__....._......................._......__.._._. Nail Line Common Bond Standard Application Requires 4 Nails/Fasteners J" ,7f$:. - - - ~ - _ -�- = Nail Line 5-7/8 Figure 7. CambridgeTm and CRC BiltmoreTM 4 Nail Pattern (non-HVHZ only) _ — Nail Line Common Bond Steep Slope/High Wind Applications +_ Requires 6 Nails/Fasteners ` 7/8 - - - -.- - - - - - - -'i Mail Line Figure 8. Cambridgerm and CRC BiltmoreT"' .........._.-.-_................... .............................._.......................................................6..Nail Pattern IKO19002 FL30310 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. G R E E K IKO INDUSTRIES,LTD Asphalt Shingles A TECHNICAL SERVICES, LLC ....._._......_........_...._..........................._...................._............,.._._._..._....__............................_......_....___...... ......................_......_......._........__......_.._._............................................................._........_...__..................._........ .....__.........,._...._...........__................._.... , CRC SuperglassTA° Basic Wind Speed�Vwc):._..._...._Max.__1_94._mPh........._.._....._._......._............. ..............._...............__......................................................................... _.... (Calgary(Non-HVHZ), : Basic Wind Speed(Val): t Max_ 150 mph _.._........_................. Hawkesbury,&Toronto Deck(HVHZ): In accordance with FBC requirements; (Non-HVHZ)) Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing and construction. ..._.._................._..........._..._.._......._....._......_._.._---._._.......;......._........_........................................._... ._.._....................................................._..........._.........._..._...................._............._._...._...._................. ; i Deck(Non-HVHZ): i Solidly sheathed in accordance with FBC requirements. i MarathonT"" Plus AR r........................................._..._....._.._..._.__.............._..._...._..._._.�_..................... ...._.._....__......_......._..._...._.._..---..._.._....._...._.__._..._......... .. . . .... _............ Underlayment:............................_ i In accordance with FBC requirements._........_..........._._..._.._........_._.....__..._........_.._......_.. Non-HVHZ ............................... ..�........._._...........__ __. ................_................._.._..............._.. (Calgary( ), Min.slope: 2:12 and in accordance with FBC requirements. Refer to Hawkesbury, Hillsboro, the manufacturer's application instructions when installing Kankakee, Sumas Non- ( . i shingles a..slopes greater.than 21:12. . _ HVHZ ,Sylacauga& I..... ............................._........................_..................._......__�....._.._.... .- _ _...... ..............................._ : Installation (HVHZ): Installed with 5-7/8 in. exposure in accordance with RAS Toronto(Non-HVHZ)) 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed and below. i-.-..._.._...._._......._.....__.._..............__.__._.................__.-.-L..._.____.___..___.__._....._........__.__......_.___..........__......._......._.._.._......._.._.__.........................__.__..._..._............_..___............_! Installation (Non-HVHZ): Installed with 5-7/8 in. exposure in accordance with FBC MarathonTM requirements and manufacturer's published installation (Sylacauga) instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. ._....._..._..........__..._.._..__._...._._.............._._._..................._....---.._.................................._............................._............._....._............._..................._._..._._................_.._._.._._._.......- ... _ .......... .._..__......._._.._._..._...._............_......_.._....._._.._.-....................................._. Standard Application Requires 4 Nails/Fasteners i i a i i i i .l Sealant Strip Figure 9. CRC Superglasslm, Marathon1m Plus AR and MarathonTM 4 Nail Pattern (non-HVHZ only) i_............._........................................................._......._._._...____.._..._.............__........................_....._-..............._....._.._------------ _........._......____.._........._._........._...................._....................__._..........................__..._._..__......_.............................................................................. j t Steep Slope/High Wind Applications Requires 6 Nails/Fasteners i i t Sealant Strip Figure 10. CRC SuperglassT", MarathonTM Plus AR and MarathonTM 6 Nail Pattern IKO19002 FL30310 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK IKO INDUSTRIES,LTD Asphaltsphalt Shingles TECHNICAL SERVICES, LLC ....................._......_....._..._........_..............._......._._...._.........._...__...,...........__._.. -_------...-__..-........__................._.....-.........,_... .........._._...._....................__.......-_..-.............._-...................................................._.-.._.....__..................................................._......... ................. Hip S Ridger"" 12 ....Basic Wind Speed...(V,�t).............Max.. ............. ............................... ...... (Kankakee&Sylacauga) Basic Wind Speed�Va ): Max. 150._m.Ph__............_....._...__._._.........................._._._.__. _._......... i Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. _.._..__............._............_........_.._._.._...+ _._...._..._...__..-.... __._._.................. ..... ....... ........s Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements. ......_.__.-._.._......_.. ._- -- ..._ .. �.__.._......_ ... ..... . Underlayment: In accordance with FBC requirements. __._.._ Min.slope: 2:12 and in accordance with FBC ire_requments. Installation: Installed with 5-5/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the ................._........................-..............................._..._._................._ __..............................................._..._......_......_..........._.............._.J�rilin..._..--._._........9.wind. ...._..._.._........................_..__............._.._.._.__............................_........................................_._................ _.......... prevailing Perforation Marks Start Direction of prevailing wind here— Nails oo 1 1 1"Taper Cut 1 , R Figure id ................ _11. ._Hi.. ..8.... —eTM �_2..._ ._......................___......._................------_ ................ IKO19002 FL30310 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. N CREEK IKO INDUSTRIES,LTD '' Asphalt Shingles F TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 6) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 7) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. 2019 08 15 CE•fV S• S �� tiP F 14:22:07 No 74021 ,. = -04'00' �5' STATE OF .'U� :�,�N .c p ••'�W� Zachary R. Priest, P.E. i�i'�S• O R �•• �j�`.` Florida Registration No.74021 Organization No.ANE11669 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT IK019002 FL30310 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.