Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-103 Builder Name: Street: 2628 CONIFER DR Permit Office: City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2317.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2035.40 ftz b. Frame - Wood, Adjacent R=11.0 282.33 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (2503.0 sqft.) Insulation Area a. Under Attic (Vented) R=40.0 2503.00 ftz 6. Conditioned floor area above grade (ftz) 2503 b. N/A R= ftZ Conditioned floor area below grade (ftz) 0 . N/A R_ z 11. R ftz 7. Windows(327.6 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 684 a. U-Factor: Dbl, U=0.62 327.63 ftz SHGC: SHGC=0.25 b. U-Factor: N/A ftz 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:16.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Strip Heat 30.1 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 4.344 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (2503.0 sqft.) Insulation Area a. Electric Cap: 50 gallonsEF:0.940 a. Slab -On -Grade Edge Insulation R=0.0 2503.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15. Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 72.04 PASS Total Baseline Loads: 79.13 I hereby certify that the plans and specifications covered by Review of the plans and ST,gTe� this calculation are in compliance with the Florida Energy specifications covered by this 0t•T"E Code. v calculation indicates compliance Florida ti ` �� "`�t with the Energy Code. mm'���; - PREPARED BY: DATE: 3/20/2020 Before construction is completed this building will be inspected for compliance with Section 553.908 , ¢ I hereby certify the�skl� g, as ned, is in compliance the Florida energy Code. Florida Statutes. with OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402�#t,,)nlEapsE®®R C7,OE COMPLIANCE ST. LUCIE COUNTY 3/19/2020 2:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Complian Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY ICNFCICI IST RFPnPT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-103 User 1 Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 2503 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 2628 CONIFER DR County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int.Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 2503 24279.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2503 24279.1 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 211 ft 2503 ft2 ---- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area , Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 2799 ft2 0 ft2 Medium N 0.4 N 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2503 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 2503 ft2 0.1 Wood 3/19/2020 2:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 t-UKM K4U5-zU1 i - INVU I SUMMARY GHEGKLI5T REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below t To Wall-TypP p R--Value Ft In- Ft In Area R- skw--ractionAbsor Grade°/ 1 N Exterior Concrete Block - Ext Insul Main 4.1 39 8 9 4 370.2 ft2 0 0 0.3 0 2 E Exterior Concrete Block - Ext Insul Main 4.1 60 8 9 4 566.2 ft2 0 0 0.3 0 3 SE Exterior Concrete Block - Ext Insul Main 4.1 1 5 9 4 13.2 ft2 0 0 0.3 0 .4 S Exterior Concrete Block - Ext Insul Main 4.1 61 6 9 4 574.0 ft2 0 0 0.3 0 5 W Exterior Concrete Block - Ext Insul Main 4.1 54 10 9 4 511.8 ft2 0 0 0.3 0 _ 6 - Garage Frame - Wood Main 11 30 3 9 4 282.3 ft2 0 0.25 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood Main None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.25 N 16.0 ft2 6 ft 0 in 0 ft 2 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.25 N 36.0 ft2 2 ft 0 in 1 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.25 N 36.0 ft2 2 ft 0 in 2 ft 0 in None None 4 n 1 Metal Double (Clear) Yes 0.62 0.25 N 8.0 ft2 6 ft 0 in 3 ft 0 in None None 5 e 2 Metal Double (Clear) Yes 0.62 0.25 N 7.8 ft2 2 ft 0 in 1 ft 0 in None None 6 e 2 Metal Double (Clear) Yes 0.62 0.25 N 5.8 ft2 2 ft 0 in 1 ft 0 in None None 7 e 2 Metal Double (Clear) Yes 0.62 0.25 N 6.0 ft2 2 ft 0 in 1 ft 0 in None None 8 e 2 Metal Double (Clear) Yes 0.62 0.25 N 7.0 ft2 2 ft 0 in 1 ft 0 in None None 9 s 4 Metal Double (Clear) Yes 0.62 0.25 N 21.7 ft2 2 ft 0 in 1 ft 0 in None None 10 s 4 Metal Double (Clear) Yes 0.62 0.25 N 43.3 ft2 2 ft 0 in 1 ft 0 in None None 11 s 4 Metal Double (Clear) Yes 0.62 0.25 N 96.0 ft2 9 ft 0 in 1 ft 4 in None None 12 w 5 Metal Double (Clear) Yes ' 0.62 0.25 N 14.0 ft2 2 ft 0 in 1 ft 0 in None None 13 W, 5 Metal Double (Clear) Yes 0.62 0.25 N 30.0 ft2 2 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 661 ft2 661 ft2 64 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000431 2832.6 155.5 292.45 .1615 ' 7 3/19/2020 2:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INP11T Rl1MMORY CI4FCKI IRT RFPnPT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 30.07 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 46.5 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / -- Supply --- �/ # Location R-Value Area - - Return --- Location Area Leakage Type Air Handler CFM 25 CFM25 TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 684 ft2 Attic 321 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingJan Feb HeatinJan X Feb Ventin Jan [ Feb Mar XMarAPr X Mar [ Ceiling Fans: A r IMa rj JunX Jul MayJun 4 Jul A r l Ma Jun [ Jul X Au Au11S Aug Se Sep e Oct Oct Oct Nov Nov HX Nov Dec Dec Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM Cooling (WEH) AM PM Heating (WD) AM PM Heating (WEH) AM PM 78 80 78 78 66 68 66 68 78 80 78 78 66 68 66 68 78 78 78 78 66 68 66 68 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 66 66 68 68 68 68 78 78 78 78 68 68 68 68 78 80 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 3/19/2020 2:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 46.5 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2503 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 30.1 c) Area 7c. 327.6 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired,natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF . 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 40.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complie with the Florida Building Code, Energy Conservation, through the above energy saving features which will be instal d (o exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed bas d on nstalled code compliant features. Builder Signature: Date: VW11002j) Address of New Home: 2628 CONIFER DR City/FL Zip: FORT PIERCE, FL 34951 3/19/2020 2:57:07 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 +�- wrightsoft. Load Short Form Jo Oct z7,zo,9 Entire House By: Project For: MW-103 1 2628 CONIFER DR, FORT PIERCE, FL 34951 Design Information Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (°F) 70 72 Construction quality Semi -tight Design TD (°F) 27 19 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) 0 65 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade 14ACX SERIES Model Cond 14ACX-047-230" AHRI ref Coil CBX27UH-048-230*++TDR AHRI ref 3869174 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.8 kW Sensible cooling 32550 Btuh Heating output 30073 Btuh Latent cooling 13950 Btuh Temperature rise 18 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.69 ROOM NAME Area (ftz) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 305 4700 3891 242 181 HIS WIC 40 821 856 42 40 MASTER BATH 166 1780 2083 92 97 HER WIC 74 61 266 3 12 DEN 201 4174 3135 215 146 FOYER 69. 1464 1364 75 64 DINING 175 2504 2214 129 103 MECH 34 414 692 21 32 UTILITY 59 72 769 4 36 BATH 2 58 994 1129 51 53 BED 2 180 1714 2783 88 130 BED 3 178 1759 2798 91 130 BATH 3 58 1657 1345 85 63 NOOK 147 3476 2673 179 125 KITCHEN 222 185 1956 10 91 (_SCAT BRA AAc onoc An7n nnc nnn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Oct-29 15:24:33 t + wrightsoft' Right -Suite® Universal 2012 12.1.05 RSU02818 Page 1 A & C:\Users\Jason\Documents\Wrightsoft HVAC\MW-103.rup Calc = MJ8 Front Door faces: N V I ILI I T n/-NLL y5 SUU j,j� lb 15 Entire House 2507 30062 33266 1550 1550 Other equip loads 0 0 Equip. @ 0.95 RSM 31769 Latent cooling 14837 TOTALS I 2 I I I I 507 30062 46606 1550 1550 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � + WrightS00V Right -Suite® Universal2012 12.1.05 RSU02818 J.�im C:\Users\Jason\Documents\Wrightsoft HVAC\MW-103.rup Calc = MJ8 Front Door faces: N 2019-Oct-29 15:24:33 Page 2 -- wrightsoft Project Summary Entire House Project Information For: MW-103 2628 CONIFER DR, FORT PIERCE, FL 34951 Notes: Design Information Weather: Vero Beach Municipal AP, FL, US Job: Date: Oct 27, 2019 By: Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 72 OF Design TD 27 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25268 Btuh Structure 24912 Btuh Ducts 4795 Btuh Ducts 8353 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30062 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 31769 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 12578 Btuh Ducts 2259 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ftZ) 2507 2607 Equipment latent load 14837 Btuh Volume (fl') 24389 24389 Air changes/hour 0.22 0.11 Equipment total load 46606 Btuh Equiv. AVF (cfm) 89 45 Req. total capacity at 0.70 SHR 3.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade 14ACX SERIES Model Cond 14ACX-047-230* AHRI ref Coil CBX27UH-048-230*++TDR AHRI ref 3869174 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.8 kW Sensible cooling 32550 Btuh Heating output 30073 Btuh Latent cooling 13950 Btuh Temperature rise 18 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.69 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrli htSOft' g 2019-Oct-2915:24:33 Right-Suite®Universal 2012 12.1.05 RSU02818 C:\users\Jason\Documents\Wrightsoft HVAC\MW-103.rup Calc = MJ8 Front Door faces: N Page 1 GHO HOME5 MW-103 2625 CONIFER Dig FORT PIERCE, FL 34951