Loading...
HomeMy WebLinkAboutWH SpecsResidential Electric Water Heater mommonomwom Lowboy Models Model Capacity Recovery A B C D V Number 90°FRise Floor to Jacket Floor to Floor to Apumxu Shipping 1st Hour Heater Top Oia. Water 7&P W6lghl U.S. he Gal. Gal. Runs Energy U.S. lon Conn. Conn. (Gala Factor GPH' GPA' In. In. in. in. RE120L6 19 16 — — 21 18 247/e 18 '191h/24r/e. per. E230LN - 28 23 43 0.95 21 18 255/e 65 RE230L6r 28 23 45 0.95 21 18 30 297A 23 30 71a 231A 102 RE240LN0 37 31 50 0.95 21 22 30a/a 24 1/e/365/a 108 RE240U3" 38 32 55 0.95 18 32 24 1h 339a 23th 126 RE250Lfi" 47 39 58 21 18 32 V. 24 33+12: 24 V 133 V 140 0.95 21 18 335/e 26 34a/e 24Va/34a/e 173 Model Capacity Recovery A 8 C D Number 50°C Rise Hour to Jacket Floor to Floor to Approx. Shipping tat Nour Heater TOP Dia. Water T&P Weight Rating Energy LRers( Conn. Conn. Liters (Liters) Factor Hour mm. mm, mm. mm. kg. RE720L6 RE23OLN6 72 106 — 80 632 457 651. .486!632 29 RE230L6'- 106 163 170 0.95 0.95 80 762 584 7&4 591 46 RE24OLN6 140189 0.95 80 80 759 559 781 613/778 49 RE240L6"' 144 208 0.95 60 613 829 622 845 803 57 RE25GL6"' 178 220 0.95 1 80 RR4 610 RRn 851 """ 613/854 _,......_- 64 __ "Models include supplied insulation blanket (2° thick). Dimensions in charts above do not include blanket thickness. For 10 year models, change suffix "6" to "10". ' Based on 450OW/450OW, Non -Simultaneous operation. All models available with optional top T&P location (Plugged). t Exempt from ASHRAE 90.1 b (current standard). Energy Factor and First Hour Rating are based on the latest AHRI directory listings. A(GPH based on Non -Simultaneous operation, when Simultaneous operation the GPH will approximately double.) 'Not available on RF23OLN6. Optional fir„ AnodeTop T&P (RE230LN6, RE240LN6, Location & RE25016 only) C D A •"D" dimension listed as side/top. General: Meets NAEGA Requirements. All models ETL listed. These heaters are wired inter -locking (Non -Simultaneous, Single Phase) 240V with two 45DOW elements, unless otherwise specified. All water and electrical connections are 3/4" NPT (19mm). All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa.) Dimensions and specfications subject to change without notice in accordance with ourpolicy of continuous product improvement BRADFOtm [NHf7E For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative. Sales 800.5232931 a Fax 216-641.1670 /Technical Support 800.334.3399 • Fax 269.795.10&9 r Warranty 800-531-2111 • Fax 269-795.1089 W Ambler, PA ..�ImemaBonal: Telephone 215.641-9400 • Telefax 216.641.9750 / wwwbradfordwhite,com B 9 KW1TE-CANADA'/NC. Sales/ Technical Support 866-690-09611905-238-0100 -Fax 905-238-0105 / www.bracifordwhhe.com Built to be the BestTM 1203-C-0916 02016, Bradford White Corporation. All rights reserved. Printed in U.S.A.