HomeMy WebLinkAbout3 quarter inch poly325-1 LEVap Acting Design fOP 2Psi Piping Syst,l,, AvqaXitrol's 325-LSeries line Pressure regulators are for 2 psi Piping systems". 325 Series regulators are for use on residential, commercial, and industrial applications. The 325 Series features a high leverage linkage assembly to deliver Positive dead-end lockup. The regulators are capable Of Precise regulating Control from full flow down to Pilot f)DW. Pipe Six -el, .................................. 316- to 2- threaded connections with NPT or IS07-7 threads. Housing Ma.teria., .....................325-3L, 325-5L, 325-7AL32 , 5-9L: aluminum. Mounting ................................. Suitable for Multi -Positional mounting- If ball check vent limiting device is install6d, mount in an upright P0519,011 only. NOTE. All Maxitrol gas pressure regulators should be installed and operated in accbrdance Witl) Maxitrol Safe tY 'Warning Instructioyis (see GPR—CSA 2pSLMLEN.FR). Certification, .............................. 325-3 L, 325-.�L, 32-5-7AL, 325-9L: ANSI Z2 7.80/CSA Gas Types .................................. Suitable for natural, manufactured, mixed gases, 6.22 Line Pressure Regulators. Mixtures. liquefied Petroleum gases, and LP MaximumMaximumInlet Pressgas-air ure ........... 2 psi (73,8 kPa) inimur M n Inlet pressure.... ....... I Psi (6.9 kPa) Emergency Exposure Limits....... 65 psi (450 kPa) (inlet side only) A4axhnurn Individual Load ........ Largest single appliance served by the regulator: 325-3L- 1401000 Btu/h; Capacity ...... ................ 323-5L: 42.5,000 Btu/h; 325-7AL: 1,250,000 BtU/b; 325-9L,2,250,000 Btulh ............ Total load of Multiple appliance combined 325-3 L (318,111 11211): 250, Ooo )3t 325 -SL (112"): 500,000 Btu/h; 325 -SL (314, 1`): 600,000 Btulh; 325-7AL (1 1/4", I 112"'): 1,250,000 Btu/h; 3'25-9L (1 1/2"1 21'): 2,250,000 Btu/h NOTE. Capacities are used to determine the m ax'MuM multiple appliance load. The largest single appliance served by the regulator should not exceed th.e maximum specified above.. individualload -40 to 205°F (40 to 96°C) Ambient Temperature Ranges.... Minimum Regulatijon ................. Suitable for pilot flow applications. Up (Circle P) (0.15 CFH NG), .................325 3L, 325-51., 325-7ALI 325-9L Models may be ordered with Imblue TechnologyTm limblue Technology N increases corrosion resistance and Provides extra protection against the. elements for regulators used in outdoor applications. Add ... when ordering. --------- suffix letter "B" to' mode] -number FAE 02015, Maxitrol C0110 -Y. All Right, R,,,,,,j in CFH (m%) @ 0,64 ._.\ 1. f, *--\ ' UNE REGUQ A TuRS -1° us Model Pipe size Outlet Pressure Operating Inlet Pressure -�-- Set Point 1I2 psi 3/4 psi i 11/2 (3.4 kPh) (5.2 kpa) (6,9 kSPa) psi (10.3 kPa)2 Psi 7.0" W.C. 145 207 (13..8 f(pa) 325-3L 3/8" x 3/8" 1 /2" x 1/2" (1.7 kPa) (4,1) 250 (7.7) 250 250 10.0" v,, C. (2.5 kPa) 710 180 (58) 230 (7.7) 250 (7.1) 7.0" w,c. (3.1) 360 (6.5) (7.1) 250 (7.1) 325-5L 7/2" x 1/2" (1.7 kPa) (10.2) 485 (13.7) 500 (14.2) 500 Soo 10.0" w,c. 275 (74.2) (14.2) l2.5 kPa) (7.8) (1375) 500 (600 Soo 500 325-51 3/4" x 3/4" 7.0" w.c. (1.7 kPa) 370 (10.5) 520 600 1600 600 (74.2) 1"x 7" 10.0" W.C. 275 (74 (17.0) (17.0) 600 (77.0) (2.5 kPa) (7.B) 450 (12,7) 570 (16'1) 6D0 600 325-7AL 1 1/4" x 1 7/4" 7.0"wc, (1,7 kPa) 7S0 (21.2) 7000 1250 1250 1 7/2" X 1 1/2" 7 0.0" (28.3) 35 (.4) (35.4) i25D w c. (2,5 kPa) 525 900 (25,5) 1250 (35.4) 7250 325-9L 1 7/2" x 7 1/2" 7.0" w.c. (1.7 kPa) (39.4). 2.OB0 (37 9} 2250 (35.4) 2250 ) 2" x 2" 10.0" W.C. 1050 (58.9) (63.7) (63.7) 2250 (63.7) NOTE: See pages 58-59 for 12.5 kPa) (29.7) 7 66.0 2090 (59.2) 2250 2250 Regulator Sizing Requ.Irements and EExamples47.D) (63.7} (63, 7) Pp'RO PO OPOP expressed in GFH (mR/h) L 0.64 sp gr flan Model Number 7.0" w c. (1.7 kM) 325-3L 1/2 psi (3.4 kPa) 145(4.o) 325-5L 204 (5,8) 400 (17.3) 550 (15.6) 325-7AL 815(23. 1) 325-9L 7149 (32.5) 1360 (38.5) 2113 (59,8) Spt 4 $06p lien Outlet Pressure Range (all models) Certified Spring ............................. 7" to 17" w c. (7.7 to 2,7 kPa) NOTE: See to pages 56-57 for complete Sp -ring Selection Chari O2'D75 Maxitrol Company. A11 Rights Reserved. 3/4 psi (5 kPa) 25- 0 ( 670 (19., t)) 1405 (39,8) 2557 (7-7 A) 325A. SEMES Lever Acting Design for 2 psi Piping Systen7s Ok'Ronsl®ns Model Pipe size ve➢➢� 5e�uing V�a�liaas Din, ensiGns 0 C 325-3L 318"1 1/2" 1/8" NPT 3" 3.5° (89 mm) (108 mm) (98 mm) 325-3L 1/2", 3/4", 1" 3/8" NPT 4'9" 5.3" 5.9" 5 4„ {124 mm) (133 mm) (149 mm) (138 mni) 325-7AL 1 1/4", 1 1/2" 1/2" NPT 6.1„ 7.3" 811 7 " (156 mm) (184 mm) (203 mm) (178 mm) 325-9L 1 1/21, 2" 7/2" NPT 7-8" 9.4" 10.8" 9.1„ N'OE'L: Dimensions are maximums and to be (798 mm) (239 mm) (274 mm) (231 mm) used only as an aid in designing Actual production dimensions clearance for the valve. may vary somewhat from those shown. -MJ 1(, 325_31 MR M 325-5L 02D75, Maxitrol Company. All RInl,r- ?—.,, _j GAS PIPING INSTALLATIONS 48 FLORIDA BUILDING CODE - FUEL GAS, 6th EDITION (2017) TABLE 402,4(22) Gas Natural POLYETHYLENE PLASTIC PIPE Inlet Pressure 2.o psi° Pressure Drop 1.0 psi Specific Gravity 0.60 Nominal OD 9/ 3 PIPE SIZE (inch) Designation SDR 9 SDR 11 SDR 11 1'/a SDR 10 1'/z 2 3 4 Actual ID 0.660 0.860 1.077 1.328 SDR 71 SDR 71 SDR 11 SDR 11 Length (ft) 1.554 1.943 2.864 3.682 Capacity in Cubic Feet of Gas per Hour 10 20 1,860 1,280 3,720 2,560 6,710 11,600 17,600 31,600 87,300 169,000 30 1,030 2,050 4,610 3,710 90 12,100 2 1,700 60,000 116,000 40 878 1,760 3,170 6,4 0 9,690 17,400 48,200 93,200 50 778 1,560 2,810 _5,490 8,300 14,900 41,200 79,700 60 705 1,410 2,550 4,870 7,350 13,200 36,600 70,700 70 649 1,300 2,340 4,410 6,660 12,000 33,100 64,000 80 603 1,210 2,180 4,060 6,130 11,000 30,500 58,900 90 566 1,130 2,050 3,780 5,700 10,200 28,300 54,800 100 535 1,070 1,930 3,540 5,350 9,610 26,600 51,400 125 474 949 1,710 3,350 5,050 91080 25,100 48,600 150 429 860 1,550 2,970 4,480 8,050 22,300 43,000 175 395 791 1.430 2,690 4+060 7,290 20,200 39,000 200 368 736 1.330 2,470 3.730 6,710 18,600 35,900 250 32fi f>52 1,180 2,300 3,470 6,240 17,300 33,400 300 295 591 2,040 3,080 .5,530 15,300 29,600 350 272 544 1,070 1,850 2,790 5,010 13,900 26,800 400 253 506 981 913 1,700 2,570 4,610 12,800 24 7 00 450 237 475 856 1.580 ---:','-)4-0 2,390 4,290 11,900 22,900 , 500 224 448 809 1,480 4,020 11,100 21,500 550 213 426 768 0 2,120 3,800 10,500 20,300 600 203 406 733 1,330 0 2.010 010 3,610 9,990 19,300 650 194 389 1,270 1,920 3,440 9,530 18,400 700 187 374 702 1,220 1,840 3,300 9'130 17,600 750 180 360 674 649 1,170 1,760 3,170 8,770 16,900 800 174 348 627 1,130 1,700&2,370 ,450 16,300 850 168 336 607 1,090 1,640,160 15,800 900 163 3�6 588 1,050 1,590 890 15,300 950 158 317 572 1,020 1,540650 14,800 1,000 154 308 556 990 1.500 430 14,400 1,100 146 293 525 363 1,450 230 14,000 1,200 139 279 504 915 1,380 870 13,300 134 267 482 873 1,320 550 12,700 128 257 463 836 1,260 2,270 6,270 12,100 %1,500 124 247 44(i773 803 1,210 2,180 6,030 11,600 119 239 431 1,170 2,100 5,810 11200 1,700 115 231 417 747 1,130 2,030 .5,610 10,800 1,800 117 ��1 404 723 1,090 1,960 5,430 10,500 1,900 109 218 393 701 1,06(1 1,900 5,260 10,200 2,000 106 212 332 680 1,030 1,850 5,110 9,900 For ST: 1 inch = 25.4 nim, 1 foot = 304.8 mm, 1 pound per square inch 662 1,000 1,800 4,970 9,600 1 British thermal unit per hour = 0,2931 W, 1 = 6.895 kPa, 1 -inch water column = 0.2488 kPa, Note: All table entries have been cubic foot per hour = 0.0283 m*1/h, 1 degree= 0.01745 rad. rounded to three significant digits. 48 FLORIDA BUILDING CODE - FUEL GAS, 6th EDITION (2017) Job Name Job Location Engineer Approval _ Contractor Approval Contractor's P.O. No, Representative SKU I • f I oL: L %1-- I i, ! -_ S ria' Flexible Gas Applianci� The flexible connection between the gas supply and the gas' inlet of a Genera& Stationary Outdoor Backup/Standby Generator, Features • Operating Temperature -40°F to 150°F (-40°C to 65.6°C) • Operating Pressure MAX 0.5psi (3.45 kPa) ® Hydrostatic Burst Pressure MIN 250psi (1725 kPa) Flexible Tube Material Annealed 304 Stainless Steel Flare Nut Material Carbon Steel with Zinc Trivalent Chromate Plating ® Flare Adapter Material Carbon Steel with Zinc Tdvalent ;Chromate Plating CSA Group Certificate of Compliance to Product Standards ANSI Z21.75/CSA 6.27 — Connectors for Outdoor Gas Appliances and Manufactured Homes Scope states "...intended for exterior use above ground for making non -rigid connections... between the gas supply and the gas inlet of an appliance for outdoor installation that is not frequently moved after installation." In addition section 1.5.4 states the connector is designed for occasional movement after installation. Repeated bend- ing, flexing or extreme vibration must be avoided. Normal opera- tion of a clothes dryer, rooftop HVAC unit or SIMILAR OUTDOOR APPLIANCE DOES NOT constitute extreme vibration or movement. ANSI 221.24/CSA 6.10 — Connectors for Gas Appliances (Excluding 60/61 Series) CIP - G us Product Configurations ES-D-GAC_Generator_G enerac For use with Generac stationary outdoor backup/ standby generators. Series 30, 40 and 60 Applicable Codes ANSI Z223.1/NFPA 54 National Fuel Gas Code Section 9.6 International Fuel Gas Code QFGC) Section 411.1 6149.1 — Natural Gas and Propane Installation Code (CSA Group) Section 6.21 Uniform Mechanical Code (UMC) Section 1313,0 Uniform Plumbing Code (UPC) Section 1212.0 Additional Approvals Commonwealth of Massachusetts Board of State Examiners of Plumbers and Gas Fitters Additional Testing UL2200-2015: Stationary Engine Generator Assemblies Section 66B Vibration Test. OL4835A CAN30-3131-146L 30 in I / in I % in in y2 14 OL4836A CAN40 4141-14GL 40 / 1 s/a 14 OL4836G CAN60-6161-15GL 60 1 ra 1'/2 1'/ 15 .CAN" prefix indicates product supplied WM both English and french instructions for Canada All installations must completely comply with all Dormont manufacturing company warnings and instructions, national, state and local codes and all applicable ansi standards. Dormont pmOuct specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Dormont Technical Service. Dormont reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Dormont products previously or subsequently sold. Refer to the owner's manual for warranty information. Di6fmOflto 4 WATTS Brand Minimum How Capacity at Specified Pressure Drop (Straight Length BTU/hr. NATURAL CAS, 0.64 SG, 1000 BTU/cu.ft.) Generac Part Number Dormont Part Number SERIES I Nominal ID in Nominal Length in 0.50 in 0.75 in 1.00 in 1.25 in 1.50 in 1.75 in 2,00 in OL4835A CAN30-3131-14GL 30 % 14 174,500 213,500 246,500 275,500 302,000 326,000 349,000 OL4836A CAN40-4141-14GL 40 4 14 338,500 414,500 478,500 535,000 586,000 633,000 677,000 OL4836C CAN60-6161-15GL 60 1%a 15 1,171,500 1,434,500 1,656,500 1,852,000 2,029,000 2,191,000 2,343,100 (Straight Length BTU/hr. LP GAS, 1,55 SG, 2500 BTU/cu.ft.) cOINIFORATIOUDROP Generac Part Number Dormont Part Number SERIES Nominal ID in Nominal Length in a50 in 0.75 in 1.00 in [INCHES, WATER 1.25 in r 1.50 in L75in 200 in OL4835A CAN30-3131-14GL 30 '/2 14 279,200 341,600 394,400 440,800 483,200 521,600 558,400 OL4836A CAN40-4141-14GL 40 3/a 14 541,600 663,200 765,600 856,000 937,600 1,012,800 1,083,200 OL4836C CAN60-6161-15GL 60 1 '/ 15 1.874.400 2.295.90n 2 95n 4nn 2 qFs 2nn s gar, ann 4 mr, ann a yea unn Dormont part number CAN30-3131-146L can supply a minimum of 349,000 BTU/hr. of natural gas Q 2.00 in. water column pressure drop to the generator. D� �rmonr A VWMM Brand ES-D-GAG_Generator Generac 1651 USA: Tel: (800) 367-6668 o Fax: (724) 733-4808 - Dormont.com Canada: Tel: (905) 332-4090 e Fax: (905) 332-7068 e Dormont.ca Latin America: Tel: (52) 81-1001-8600 a Fax: (52) 81-8000-7091 e Dormont.com © 2016 Dormont Do �l A -3- T7, LI, Tl[ �r� 1�-( E-A fa ........... Fougufto Me con -220 HUMUS iffim cardflneflM M JOHOMOO, unc. I 41-71 Ti?I t i? I r-wcifoo 'Cm arq'! 1/2" CTS 625 7.0 0.090 3/4" IPS 1.050 11.0 0,095 1 " CTS 1,125 11.5 0.099 1" IPS 1.315 11.0 0,120 1-1/4" IPS 1.660 10,0 0,166 1-1/2" IPS 1.900 11.0 0,173 2" IPS 2.375 11.0 0,216 Normal Pipe Size and SDR must be used to match fittings and IPS PE pipe, Nominal Pipe Size and Min, Wall must be used to match fittings and CTS PE pipe. MDPE pipe complies with ASTM D2513, P®fent #s 5,366,280,5,692,795 & 5,353,272 Gastite Division - 1116 Vaughn Parkway - Portland, TN 37140 STEP 3 Verify the polyethylene (RE.) pipe being assembled is the correct size. STEP 2 Out pipe ends square. STEP a Clean piping thoroughly to assure there is no dirt, grease or oil in assembly area. STEP 4 Chamfer end of pipe using Continental's chamfering tool with I.D. gauge. CHAMFER T HE eti4, Q ID OF PIPE STOP Mark the stab depth by inserting the pipe into the chamfer tool and marking the pipe at the entrance as shown. STEP G If using chamfer tool with ID gauge, check for proper chamfer by inserting pipe over gauge. Stab pipe completely into fitting entrance. STEP a Stab pipe completely into fitting so that the mark on the pipe is within 1/8" from the fitting entrance. STEP 9 Repeat steps 1 though 4 for all Con -Stab joints. STEP 10 To assure proper assembly and to comply with 49 CFR 192 Subpart J -Test requirements, the joint shall be leak tested. Potent 4s 5,366,260,5,692,785 a 5,853,272 Ph: 1.600.662.0208 o Fox: 615.325.9407 - Web: www.gostife.com a ` Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 6,0 in. INC and o Pressure Drop of 0.5 in. VIC (based on a 0.60 specific gravity gas) I` ---a �IIJ 110 74 59 50 44 39 33 29 26 24 22 21 20 17 16 635 426 338 286 252 227 192 169 152 139 129 120 113 100 90 823 553 438 371 326 294 249 219 197 180 167 156 147 129 116 1173 787 624 529 465 419 355 312 281 257 238 223 209 184 166 2108 1415 1121 950 835 752 638 561 505 462 428 400 376 331 298 2765 1900 1526 1306 1158 1049 898 796 721 663 617 579 547 485 439 5954 3997 3166 2683 2360 2125 1801 1584 1426 1305 1209 1130 1063 935 842 oe a oor a© ea .ae oo :ao' •oe aae�oto ee ae .eeeo 13 12 10 9 8 7 6 6 6 5 5 5 5 4 4 76 67 60 51 45 40 37 34 32 30 29 27 26 25 24 99 .87 78 66 58 52 48 44 42 39 37 35 34 32 31 141 124 111 94 83 75 68 63 59 .56 53 50 48 46' 44 253 222 200 170 149 134 123 114 106 100 95 90 86 83 79 376 333 302 258 229 207 191 178 167 157 149 143 137 131 126 714 628 565 479 421 380 347 322 301.. 283 268 255 243 233. 224 1,000 BTUh = 1 CFH Maximum Capacity of PE Pipe in Cubic Peet per Hour with a Gas Pressure of 6.0 to 7.0 in. WC (1/4 prig) and a Pressure Drop of 1.0 in. WC (based on a 0,60 specific gravity gas) i _ e 165 111 88 74 65 59 50 44 39 36 33 31 29 26 23 947 636 503 427 375 338 286 252 227 208 792 180 169 149 134 1228 824 653 553 487 438 371 327 294 269 249 233 219 193 174 1749 1174 930 788 693 624 529 465 419 384 355 332 312 275 247 3143 2110 1671 1416 1246 1122 951 836 753 689 638 596 561 494 445 4023 2765 2221 1900 1684 1526 1306 1158 1049 965 898 842 796 705 639 8878 5960 4720 4001 3519 3169 2686 2362 2127 1947 1803 1685 1586 1395 1256 oe 250 eo oe to .ee ee :oe •ee oeo oe eo ao goo 00 20 17 16 13 12 10 10 9 8 8 7 7 7 6 6 114 100 90 76 67 60 55 51 48 45 43 41 39 37 36 147 129 117 99 87 78 72 66 62 58 55 53 50 48 46 210 184 166 141 124 112 102 95 88 83 79 75 71 69 66 377 331 298 253 223 200 183 170 159 149 141 135 128 123 118 547 485 439 376 333 302 278 258 242 229 217 207 199 191 184 X1065_--=-936 .,843,71—_.>_62Q __566,_ _618__ g80._?748===4_22 x_399--380=--363----348_—_334-, -- - 1,000 BTUh 1 CFH 4 Gastite Division o 1116 Vaughn Parkway o Portland, TN 37140 ],ODD BTUh = I CFH MOAMurn Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 12.0 to 14 in. WC (1/2 psig or less) and a Pressure Drop of 6.0 in. WC (based on a 0.60 specific gravity gas) W7 � 462 310 246 208 183 165 140 123 111 107 94 88 83 73 65 2657 1784 1413 1197 1053 948 804 707 637 Nlaxirnum Capacity of P-, Pipe in Cubic Fee" per Hour 504 475 417 376 with a Gas Pressure of 8.0m, INC and a Pmssum Drop of 3.0 in. VIC 1366 1230 1042 .917 825 755 (based on a 0.60 specific gravity gas) 615 541 487 4909 3295 2610 2212 1946 1752 1485 1306 1176 1076. 997 932 877 771 694 J 5922 __c 3975 ---- ------ 3148 2668 2347 2114 1934 308 210 166 141 124 111 94 83 75 68 63 59 5-6 4-9 --44 1773 1205 955 809 712 641 543 478 430 394 365 341 321 282 251 2298 1561 1236 1048 921 830 703 619 557 510 472 441 415 365 32S 3275 2198 1741 1476 1298 1169 991 871 785 718 665 621 585 514 463 5885 4002 3170 2686 2363 2128 1803 1586 1428 1307 1211 1731 1065 937 843 7290 5010 4.023 3443 3052 2765 2367 2097 1900 1748 1627 1526 1442 1278 115 16623 10940 8665 7344 6459 5816 4930 4336 3904 3573 3309 3093 2911 2560 230,1 244 220 201 186 174 164 155 147 141 135 130 589 206; 250 300, W 313 �vuvL 265 248 233 221 37 33 .30 25 22 20 18 17 .16 15 14 13 13 12 12 215 189 171 145 127 113 103 96 90 84 80 76 72 69 67 279 245 221 187 165 147 134 1.24 11-6 109 103 98 94 90 87 393. -7-15- 345 311 264. 232 209 191 177 165 '156 1-47 ma 134 128 123 629- 566 480 422 375 343 318 297 280 265 252 241 230 222r 991 878 796 681 604 547 503 468 439 415 394 376 360 346 333 -1954 - 1719 1548 1312 1154 1060 970 898- r 839 790 -748 711 679 651 626 ],ODD BTUh = I CFH MOAMurn Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 12.0 to 14 in. WC (1/2 psig or less) and a Pressure Drop of 6.0 in. WC (based on a 0.60 specific gravity gas) W7 � Ph: 1.800.662.0200 - Fax: 615.325.9407 - Web: www.gastite,com 51 462 310 246 208 183 165 140 123 111 107 94 88 83 73 65 2657 1784 1413 1197 1053 948 804 707 637 583 540 504 475 417 376 3445 2313 1832 1553 1366 1230 1042 .917 825 755 -700 654 615 541 487 4909 3295 2610 2212 1946 1752 1485 1306 1176 1076. 997 932 877 771 694 8821 5922 4690 3975 3496 3148 2668 2347 2114 1934 1791 1674 1576 1386 1248 10606 7290 5854 5010 4440 4023 3443 3052 2765 2544 2367 2221 2097 1859 1684 24918 16727 13249 11229 9877 8894 7538 6630 5970 5464 5060 4729 4451 3915 3525 200 250 30 *10 W M 55 49 44 37 33 29 27 25 23 22 21 20 19 18 17 319 280 252 214 188 169 155 144 134 126 120 114 109 104 100 413 363 327 277 244 220 201 186 174 164 155 147 141 135 130 589 518 466 395 348 313 286 265 248 233 221 210 201 192 185 1058 930 838 710 625 562 515 477 445 419 397 377 361 345 332 1442 1278 1158 991 878 796 732 681 639 604 573 547 524 503 485 2628:-2366 - -2006 -1.589 3454 -L -M -4a 8.4----- U21 -76, -L9 -9a8-- 1,000 BTUh = I CFH Ph: 1.800.662.0200 - Fax: 615.325.9407 - Web: www.gastite,com 51 Maxilnur" CaPacity of PE Pipe in Thousands of BTU per Hour of Liquefied Petroleum Gas with a Gas Pressure of 11.0 in.'VVC and a Pressure Grow of 0.5 In. WC (based on a 1.52 specific gravity gas) - - ,i iu Y Y 8 8 8 7 7 129 113 102 86 76 68 63 58 54 51 48 46 44 42 40 167 147 132 112 99 89 81 75 70 66 63 60 57 54 52 238 209 188 160 140 126 116 107 100 94 89 85 81 78 75 427 376 338 287 252 227 208 192 180 169 760 152 146 140 134 642 569 516 441 391 354 326 303 285 269 255 244 233 224 216 1207 1061 956 810 712 642 587 544 508 478 453 431 411 394 379 2,516 BTUh = I CFH Maximum Capacity of PE Pipe in ThousandS of BTU per of Liquefied Petroleum Gas with a Gess Pressure of 2.0 psi and a Pressure Drop of 1.0 psi (based on a 1.52 specific gravity gas) a e a o.a o a 1966 1319 1045 886 779 702 595 523 471 373 351 309 2718 11300 7586 6008 5092 4479 4033 3418 3007 2707 2478 2295 2744 2018 1775 1599 14652.. 9835 7790 6602. 5807 5229 -4432. .3898 3510 . 321a - .2975 _ 2780 2617 2302.. 2073 20877 14014 11100 9408 8275 7451 6315 5555 5002 4578. 4239 3962 3729 3280 2953 337514 25183 19946 16905 14869 13389 11348 9982 8988 .8226 .7618 .7119 6700 5894 5307. 43429. 29848 .23969 20515 18182 . 16474 14100. 12496 .1.1322__ 104)7.. 9691 9092 .:8589. 7672--. 6897 105963 71137 56339 47750 42000 37820 32054 28194 25388 23234 21517 20108 18926 16647 14990 a � - raa o ea ea as .oa ea :oa •oa oea, 00 oo 11"�eas oa, �8 236 207 787 158 139 125 715 106 99 93 88 84 80 77 74 1355 1192 1073 910 800 720 659 611 571 537 508 484 462 443 425 1757 1545 1391 1179 1037 934 855 792 740 696 659 627 599 574 551 2503 2202 1983 1680 1478 1331 1218 1128 1054 992 939 893 853 818 786 4498 3956 3563 3019 2656 2391 2189 2027 1894 1783 1688 1605 1533 1469 1412 5903 5232 4740 4057 3596 3258 2997 2788 2616 2471 2347 2239 2144 2060 1985 12705 11175 10063 8529 7502 6755 6182 5725 5350 5036 4767 4535 4331 4150 3988 2,516 BTUh = 7 CFH Maximum Capacity of PE Pipe in Thousands of BTU per. Hour of Liquefied Petroleum Gas with a Gas Pressure of 10.0 psi and a Pressure Drop of 1.0 psi (based on a 1.52 specific gravity gas) a a 'o as a 2476 1662 1376 1116 981 884 749 659 593 543 503 470 442 389 350 14234 9555 7568 6414 5642 5080 4306 3787 3410 3121 2890 2701 2542 2236 2014 18455 72388 9812 8316 7315 6587 5583 4910 4422 4047 3747 3502 3296 2899 2611 26296 17652 13981 11849 10423 9385 7954 6997 6300 5766 5340 4990 4697 4131, 3720 47252 31720 25123 21293 18729 16865 14294 12572 11321 10361 9595 8967 8440 7423 6685 53960 37087 29782 25489 22591 20469 17519 15527 14D68 12943 12041 11297 10671 9458 8569 133476 89601 70967 60148 52905 47640 40376 35514 31980 29267 27104 25329 23840 20970 18882 ZYi zbl 235 199 775 758 144 134 125 178 771 106 701 97 93Y 1707 1501 1352 1746 1008 907 830 769 719 676 640 609 582 557 536 2273 1946 1753 1485 1306 7176 7077 997 932 877 830 790 754 723 695 3153_ 2773 `5665- - ,2497_ 217.6 _ 1862 _ 7676_ _ 1534 _ _1421 1328_ 1250 1183 1125 7.030_ 990 4983= 4487-"3803- 3346" 3012 ---2757 - -2553=' -2386-:---2246-- _ 2126 = __1075_, "2022-- " 19311- "1851 ,_ _ _ `7779= 7334 6500 5890 5041 4468 4048 3724 3465 3251 3071 2916 2782 2664 2560 -- =" 2466 16004 14077 12676 10743 9449 8509 7787 7212 6739 6343 6005 5712 5455 5227 5024 2,516 BTUh = 1 CFH Ph: 1.800.662.0208 - Fax: 675.325.9407 o Web: www.gastife.com ,111 Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 2.0 psi and a Pressure Drop of 1.0 psi (based on a 0.60 specific gravity gas) ,. 1167 .,.-. 783 621 ... 526 ... 463 -J.J 417 _J 353 �2Z 311 ISM 280 '0 �.�.' 256 I, ci�j) 237 I 221 `_II: 208 183 —165 6710 4504 3568 3024 2660 2395 2030 1785 1608 1471 1363 1273 1198 1054 949 8687 5832 4619 3915 3443 3101 2628 2311 2081 1905 1764 1649 1552 1365 1229 12396 8321 6591 5586 4913 4424 3750 3298 2970 2718 2517 2352 2214 1947 1754 22276 14953 11844 10038 8829 7950 6738 5927 5337 4884 4523 4227 3979 3500 3151 25532 17548 14092 12061 10689 9685 8289 7347 6657 6124 5697 5345 5049 4475 4055 62923 42239 33455 28355 24940 22458 19034 16742 15076 13797 12777 11941 11239 9885 8902 a„140 O/[ 123 111 94 83 74 68 63 59 55 53 50 48, 46 44- 2433 805 708 637 540 475 428 391 363 339 319 302 287 274 263 253 2775 1042 916 825 699 615 554 507 469 439 413 391 372 355 340 327 3560 1486 1307 1177 998 878 790 723 670 626 589 558 530 507 485 467 -4769 2671 2349 2115 1793 1577 1420 1300 1204 1125 1059 1002 953 910 872 838 _ 3470 3076 2787 2385 2114 1915 1762 1639 1538 1453 1380 1316 1261 1211 1167 8561 7544 6636 5975 5064 4455 4011 3671 3400 3177 2990 2831 2693 2572 2464 2368 - 1 CFH 1,000 BTUh = 1 CFH Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Cas Pressure of 5.0 psi and a Pressure Drop of 3.5 psi (based on a 0.60 specific gravity gas) 2544 1708 1353 1147 1008 908 770 677 610 558 517 483 454 400 360 E` 14628 9819 7777 6592 5798 5221 4425 3892 3505 3207 2970 2776 2613 2298 2069 JIM 18966 12731 10084 8546 7517 6769 5737 5046 4544 4159 3851 3599 3387 2980 2683 27024 18141- 14368 12178 -1071.1 9645 - 8176 7190 6475 5925 5488 5128.- 4827 - 4246. 3823. 48561 32598 25819 21883 19248 17332 14689 12921 11635 10648 9861 9215 8673 7629 6870 53153 36532 29336 25108 22253 20163 17257. 15294 13858 12749 11860 11128 10512 9316 8441- 137172 92082- 72933 61813 54370 48969 41494 36498 32865 30078 27855 26031- 24500-=-21550- 19405 e &305 268 242 205 180 162 148 137 128 121 114 109 104 100 96 1754 1543 1389 1177 1036 932. 853 790 739 695 658 626 598 573 551 2274 2000 1801 1526 1343 1209 1106 1025 958 901 853 812 775 743 714 3240 2850 2566 2175 1913 1723 1577 1460 1364 1284 1216 1156 1104 1058 1017 5822 5121 4612 3908 3438 3096 2833 2624 2452 2308 2185 2078 1985 1902 1828 7225 6403 5802 4965 4401 3987 3668 3413 3202 3025 2873 2741 2624 2521 2429 16447 14466 13027 11041 9711 8745 8003 7411 6926 6519 6171 5870 5606 5372 5163 1,000 BTUh = 1 CFH Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 10.0 psi and a Pressure Dropof-5.0 psi (based on a 0.60 specific gravity gas) 3529 2369 1877 1590 1399 1260 1068 939 846 774 717 670 630 554 499 20291 13621 10789 9144 8043 7242 6138 5399 4862 4449 4120 3851 3624 3188 2871 26309 17661 13988 11856 10428 9390 7958 7000 6303 5769 5342 4993 4699 4133 3722 37487 25164 19931 16893 14858 13380 11340 9974 8982 8220 7612 7114 6696 5889 5303 67362 45220 35816 30355 26700 24043 20377 17923 16139 14770 13679 12783 12032 10583 9530 72320 49705 39915 34162 30277 27433 23479 20809 18855 17346 16137 15141 14302 12676 11485 190283 127734 101171 85746 75421 67915 57560 50629 45590 41723 38639 36109 33987 29894 26919 4LJ O/[ d -6b 284 250 225 206 191- 178 168 159 151 ` 144s 138 133 2433 2140 1927 1633 1437 1294 1184 1096 1025 964 913 868 829 795 764 .3154 2775 2498 2118 1863 1677 1535 1421 1328 1250 1184 1126 1075 1030 990 4495 3953 3560 3017 2.654 2390 2187 2025 1893 1782 1686 1604. 1532 1468 1411 -4769 = 4294 - 3930 -=3Ci40 _==34013_20_T- = 3031 -2883 '_:2753 = 2638 ---2536---_ 9830 8712 7894 6756 5988 5425 4991 4643 4357 4115 3908 3729 3571 3430 3305 22815 20067 18070 15315 13471 12130 11101 10281 9608 9043 8561 8143 7777 7452 7162 1,000 BTUh = 1 CFH Gastife Division o 1116 Vaughn Parkway o Portland, IN 37148