HomeMy WebLinkAboutAPPROVED, integ 5v paProfessional Regulation
BCIS Home Log In 1 User Registration i Hot Topics Submit Surcharge Stats & Facts, Publications Contact Us BCIS Site Map Links Search
F1 dd
Product Approval
USER: Public User
0 � - -t =
=0AM
am
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL27150-RO
Application Type
New
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Integrity Metals LLC
Address/Phone/Email 2604 B Piper Drive
Vero Beach, FL 32960
(772) 584-2654
Admin@integritymetalsfl.com
Authorized Signature Joe Keene
Admin@integritymetalsfl.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden
Evaluation Report
Florida License PE-49704
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 05/25/2025
Validated By Diane Marotta, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL27150 RO COI FL27150 5V Crimp Min. 26GA Steel w Details - RSS.pdf
Standard Year
TAS 125 2003
UL 580 2006
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
06/20/2018
Date Validated
07/30/2018
Date Pending FBC Approval
07/31/2018
Date Approved
10/08/2018
Date Revised
07/31/2020
Summary of Products
FL # i Model, Number or Name
27150.1 € 1.5 Versaloc 16oz Copper 1.5
;Mechanical Seam
Description
1.5 Versaloc 16oz Copper 1.5 Mechanical Seam over min.
15/32" plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-159.25
Other: - 159.25 PSF @ 8" O.C. clip spacing Install per
manufacturer's details and in accordance with FBC 2017.
_a
Installation Instructions
FL27150 RO II FL27150 1.5 Versaloc Mechani al Seam Min
16oz Copper w. Details - RSS�pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
i FL27150 RO AE FL27150 1.5 Versaloc Mechanical Seam Min.
i 16oz Copper w Details - RSS.pdf
Created by Independent Third Party: Yes
27150.2 1.5 Versaloc 24GA Steel 1.5
Mechanical Seam
Limits of Use
Approved for use in HVHZ: Yes i
Approved for use outside HVHZ: Yes j
Impact Resistant: N/A
Design Pressure: +N/A/-189.25
Other: - 189.25 PSF @ 8" O.C. clip spacing forming 180 i
degree seam - 121 PSF @ 8" O.C. clip spacing forming 90
degree seam - 91.75 PSF @ 16" O.C. clip spacing (
1'5 Versaloc 24GA Steel 1.5 Mechanical Seam over min 15/32"
plywood
Installation Instructions
FL27150 RO II FL27150 1.5 Versaloc Mechanical Seam Min
24GA Steel w Details - RSS.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL27150 RO AE FL27150 1.5 Versaloc Mechanical Seam Min
24GA Steel w Details - RSS.pdf
Created by Independent Third Party: Yes
27150.3 1.5 Versaloc MIN .029" Aluminum 11.5 Versaloc MIN .029" Aluminum 1.5 Mechanical Seam over
1.5 Mechanical Seam ; min. 15/32" plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-159.25
Other: - 114.25 PSF @ 16" O.C. clip spacing W/OUT sealant -
121.75 PSF @ 16" O.C. clip spacing W/ sealant - 159.25 PSF @
8" O.C. clip spacing Install per manufacturer's details and in
accordance with FBC 2017.
27150.4 i IM675 Series: MIN .029" Aluminum
1.75 Snap Lock Roof Panel
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5
Other: - 108.5 PSF @ 18" O.C. clip spacing Install per
manufacturer's details and in accordance with FBC 2017
27150.5 IM675 Series: Min. 26GA Steel 1.75
j Snap Lock Roof Panel
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-93.5
Other: - 63.5 PSF @ 16" O.C. clip spacing - 93.5 PSF @ 12"
O.C. clip spacing Install per manufacturer's details and in
accordance with FBC 2017.
Installation Instructions
FL27150 RO II FL27150 1.5 Versaloc Mechanical Seam Min
0.029 Aluminum w Details - RSS.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL27150 RO AE FL27150 1.5 Versaloc Mechanical Seam Min
0.029 Aluminum w Details - RSS.pdf
Created by Independent Third Party: Yes
IM675 Series: MIN .029" Aluminum 1.75 Snap Lock Roof Panel
over min. 15/32" 4-ply CDX plywood
Installation Instructions
FL27150 RO II FL27150 IM 675 Min. .029 Aluminum w
Details - RSS.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL27150 RO AE FL27150 IM 675 Min. 029 Aluminum w
Details - RSS.pdf
Created by Independent Third Party: Yes
IM675 Series: Min. 26GA Steel 1.75 Snap Lock Roof Panel over
min. 15/32" 4-ply CDX plywood
Installation Instructions _
FL27150 RO II FL27150 IM 675 Min 26GA Steel w Details -
RSS.pdf
Verified By: Locke Bowden, RE. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL27150 RO AE FL27150 IM 675 Min 26GA Steel w Details -
RSS.pdf
Created by Independent Third Party: Yes
771 sn F i Tntanril nlr TM1nn MTN n?o"
Tntanril nlr TM1 nn MTN n?W Ali minnm Nail Ctrin nvar min
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for HVHZ: Yes
FL27150 RO II FL27150 IntegriLok IM 100 Min. 0.029
Aluminum w Details - RSS.pdf
use outside
Impact Resistant: N/A
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/-86
Created by Independent Third Party: Yes
Other: - 57.62 PSF @ 5-1/4" O.C. fastener spacing W/OUT
Evaluation Reports
sealant - 86 PSF @ 5-1/4" fastener spacing W/ sealant Install
per manufacturer's details and in accordance with FBC 2017.
FL27150 RO AE FL27150 IntegriLok IM 100 Min. 0.029
Aluminum w Details - RSS.pdf
4Min.
Created by Independent Third Party: Yes
27150.7 IntegrlLok IM100 26GA Steel
IntegriLok IM100 Min. 26GA Steel Nail Strip over Min. 15J32"
Nail Strip
4-ply CDX plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL27150 RO II FL27150 IntegriLok IM 100 Min. 26GA Steel w
Details - RSS.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/-71
Created by Independent Third Party: Yes
Other: - 52.5 PSF @ 5-1/4" O.C. fastener spacing W/OUT
Evaluation Reports
sealant - 71 PSF @ 5-1/4" O.C. fastener spacing W/ sealant
( FL27150 RO AE FL27150 IntegriLok IM 100 Min. 26GA Steel
Install per manufacturer's details and in accordance with FBC
w Details - RSS.pdf
2017.
Created by Independent Third Party: Yes
27150.8 Min. 26GA Steel 5V Crimp Roof Panel I
Min. 26GA Steel 5V Crimp Roof Panel over min. 15/32" 4-ply
CDX plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL27150 RO II FL27150 5V Crimp Min. 26GA Steel w Details
- RSS.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/-86
Created by Independent Third Party: Yes
Other: - 63.5 PSF @ 16" O.C. fastener spacing -86 PSF @ 12"
Evaluation Reports
I O.C. fastener spacing Install per manufacturer's details and in
FL27150 RO AE FL27150 5V Crimp Min. 26GA Steel w Details
- RSS.pdf
I accordance with FBC 2017.
j I
Created by Independent Third Party: Yes
0 IEEE
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee, However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
I. ® Ed M
Credit Card
Safe
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant Active Quality Assurance Program
Yield strength: 49ksi 24" Coverage (Max.) Rib Height 3/8"
Minimum 15/32" plywood over supports at maximum 24" O.C. Design of plywood
and plywood supports are outside the scope of this evaluation. Must be designed
in accordance w/ Florida Building Code 2017.
X" penetration thru plywood supports 24" max. o.c.
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener (Method 1): #10 x 1-1/2" HiLo HWH fasteners w/ weather seal washer @ 16"O.C. at
each seam and intermediate Rib.
Fastener (Method 2): #10 x 1-1/2" HiLo HWH fasteners w/ weather seal washer @ 12"O.C.
at each seam and intermediate Rib.
Underlayment: To be compliant with FBC Sec. 1507, Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable
Loads
Method 1:
Method 2:
DESIGN PRESSURE*
-63.5 PSF
- 86 PSF
SPACING
16" O.C.
12" O.C.
Reference Data:
Intertek Testing (TST-1527) REPORT# 14625-02-450-44 RO UL 580-06
*Design Pressure safety margin of 2-1
Certificate of Independence:
Locke Bowden, P.E. does not have, nor will acquire a financial interest in any company manufacturing or distributing products
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distributing products under this
report. %i����1111111f1t#Irtf 89
0
�\CENse
No. 49704
seal
STATE OF
-/Z
•0, 0
0 R��
"'i"I/ONAU
�
"'Jami'00
Integrity Metals Min. 26GA 5V Crimp Roof Panel
Installation Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6T" ed.. see Chart 1507.1.1
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-1)
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
24
3/811
PROFILE
FASTENER PATTERN
FIELD SPACING @ 16" O.C.
PERIMETER SPACING @ 12" O.C.
ZONE Z GMLE ROOF A,
Igo"
x
ZONE I
ZONE 3 WE
EAVE