Loading...
HomeMy WebLinkAboutAPPROVED, integ 5v paProfessional Regulation BCIS Home Log In 1 User Registration i Hot Topics Submit Surcharge Stats & Facts, Publications Contact Us BCIS Site Map Links Search F1 dd Product Approval USER: Public User 0 � - -t = =0AM am Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL27150-RO Application Type New Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Integrity Metals LLC Address/Phone/Email 2604 B Piper Drive Vero Beach, FL 32960 (772) 584-2654 Admin@integritymetalsfl.com Authorized Signature Joe Keene Admin@integritymetalsfl.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Locke Bowden Evaluation Report Florida License PE-49704 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 05/25/2025 Validated By Diane Marotta, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL27150 RO COI FL27150 5V Crimp Min. 26GA Steel w Details - RSS.pdf Standard Year TAS 125 2003 UL 580 2006 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/20/2018 Date Validated 07/30/2018 Date Pending FBC Approval 07/31/2018 Date Approved 10/08/2018 Date Revised 07/31/2020 Summary of Products FL # i Model, Number or Name 27150.1 € 1.5 Versaloc 16oz Copper 1.5 ;Mechanical Seam Description 1.5 Versaloc 16oz Copper 1.5 Mechanical Seam over min. 15/32" plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.25 Other: - 159.25 PSF @ 8" O.C. clip spacing Install per manufacturer's details and in accordance with FBC 2017. _a Installation Instructions FL27150 RO II FL27150 1.5 Versaloc Mechani al Seam Min 16oz Copper w. Details - RSS�pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports i FL27150 RO AE FL27150 1.5 Versaloc Mechanical Seam Min. i 16oz Copper w Details - RSS.pdf Created by Independent Third Party: Yes 27150.2 1.5 Versaloc 24GA Steel 1.5 Mechanical Seam Limits of Use Approved for use in HVHZ: Yes i Approved for use outside HVHZ: Yes j Impact Resistant: N/A Design Pressure: +N/A/-189.25 Other: - 189.25 PSF @ 8" O.C. clip spacing forming 180 i degree seam - 121 PSF @ 8" O.C. clip spacing forming 90 degree seam - 91.75 PSF @ 16" O.C. clip spacing ( 1'5 Versaloc 24GA Steel 1.5 Mechanical Seam over min 15/32" plywood Installation Instructions FL27150 RO II FL27150 1.5 Versaloc Mechanical Seam Min 24GA Steel w Details - RSS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL27150 RO AE FL27150 1.5 Versaloc Mechanical Seam Min 24GA Steel w Details - RSS.pdf Created by Independent Third Party: Yes 27150.3 1.5 Versaloc MIN .029" Aluminum 11.5 Versaloc MIN .029" Aluminum 1.5 Mechanical Seam over 1.5 Mechanical Seam ; min. 15/32" plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.25 Other: - 114.25 PSF @ 16" O.C. clip spacing W/OUT sealant - 121.75 PSF @ 16" O.C. clip spacing W/ sealant - 159.25 PSF @ 8" O.C. clip spacing Install per manufacturer's details and in accordance with FBC 2017. 27150.4 i IM675 Series: MIN .029" Aluminum 1.75 Snap Lock Roof Panel Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: - 108.5 PSF @ 18" O.C. clip spacing Install per manufacturer's details and in accordance with FBC 2017 27150.5 IM675 Series: Min. 26GA Steel 1.75 j Snap Lock Roof Panel Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: - 63.5 PSF @ 16" O.C. clip spacing - 93.5 PSF @ 12" O.C. clip spacing Install per manufacturer's details and in accordance with FBC 2017. Installation Instructions FL27150 RO II FL27150 1.5 Versaloc Mechanical Seam Min 0.029 Aluminum w Details - RSS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL27150 RO AE FL27150 1.5 Versaloc Mechanical Seam Min 0.029 Aluminum w Details - RSS.pdf Created by Independent Third Party: Yes IM675 Series: MIN .029" Aluminum 1.75 Snap Lock Roof Panel over min. 15/32" 4-ply CDX plywood Installation Instructions FL27150 RO II FL27150 IM 675 Min. .029 Aluminum w Details - RSS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL27150 RO AE FL27150 IM 675 Min. 029 Aluminum w Details - RSS.pdf Created by Independent Third Party: Yes IM675 Series: Min. 26GA Steel 1.75 Snap Lock Roof Panel over min. 15/32" 4-ply CDX plywood Installation Instructions _ FL27150 RO II FL27150 IM 675 Min 26GA Steel w Details - RSS.pdf Verified By: Locke Bowden, RE. 49704 Created by Independent Third Party: Yes Evaluation Reports FL27150 RO AE FL27150 IM 675 Min 26GA Steel w Details - RSS.pdf Created by Independent Third Party: Yes 771 sn F i Tntanril nlr TM1nn MTN n?o" Tntanril nlr TM1 nn MTN n?W Ali minnm Nail Ctrin nvar min Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for HVHZ: Yes FL27150 RO II FL27150 IntegriLok IM 100 Min. 0.029 Aluminum w Details - RSS.pdf use outside Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-86 Created by Independent Third Party: Yes Other: - 57.62 PSF @ 5-1/4" O.C. fastener spacing W/OUT Evaluation Reports sealant - 86 PSF @ 5-1/4" fastener spacing W/ sealant Install per manufacturer's details and in accordance with FBC 2017. FL27150 RO AE FL27150 IntegriLok IM 100 Min. 0.029 Aluminum w Details - RSS.pdf 4Min. Created by Independent Third Party: Yes 27150.7 IntegrlLok IM100 26GA Steel IntegriLok IM100 Min. 26GA Steel Nail Strip over Min. 15J32" Nail Strip 4-ply CDX plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL27150 RO II FL27150 IntegriLok IM 100 Min. 26GA Steel w Details - RSS.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-71 Created by Independent Third Party: Yes Other: - 52.5 PSF @ 5-1/4" O.C. fastener spacing W/OUT Evaluation Reports sealant - 71 PSF @ 5-1/4" O.C. fastener spacing W/ sealant ( FL27150 RO AE FL27150 IntegriLok IM 100 Min. 26GA Steel Install per manufacturer's details and in accordance with FBC w Details - RSS.pdf 2017. Created by Independent Third Party: Yes 27150.8 Min. 26GA Steel 5V Crimp Roof Panel I Min. 26GA Steel 5V Crimp Roof Panel over min. 15/32" 4-ply CDX plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL27150 RO II FL27150 5V Crimp Min. 26GA Steel w Details - RSS.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-86 Created by Independent Third Party: Yes Other: - 63.5 PSF @ 16" O.C. fastener spacing -86 PSF @ 12" Evaluation Reports I O.C. fastener spacing Install per manufacturer's details and in FL27150 RO AE FL27150 5V Crimp Min. 26GA Steel w Details - RSS.pdf I accordance with FBC 2017. j I Created by Independent Third Party: Yes 0 IEEE Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee, However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: I. ® Ed M Credit Card Safe Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant Active Quality Assurance Program Yield strength: 49ksi 24" Coverage (Max.) Rib Height 3/8" Minimum 15/32" plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. X" penetration thru plywood supports 24" max. o.c. Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener (Method 1): #10 x 1-1/2" HiLo HWH fasteners w/ weather seal washer @ 16"O.C. at each seam and intermediate Rib. Fastener (Method 2): #10 x 1-1/2" HiLo HWH fasteners w/ weather seal washer @ 12"O.C. at each seam and intermediate Rib. Underlayment: To be compliant with FBC Sec. 1507, Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads Method 1: Method 2: DESIGN PRESSURE* -63.5 PSF - 86 PSF SPACING 16" O.C. 12" O.C. Reference Data: Intertek Testing (TST-1527) REPORT# 14625-02-450-44 RO UL 580-06 *Design Pressure safety margin of 2-1 Certificate of Independence: Locke Bowden, P.E. does not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distributing products under this report. %i����1111111f1t#Irtf 89 0 �\CENse No. 49704 seal STATE OF -/Z •0, 0 0 R�� "'i"I/ONAU � "'Jami'00 Integrity Metals Min. 26GA 5V Crimp Roof Panel Installation Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6T" ed.. see Chart 1507.1.1 2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference. 3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-1) 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 24 3/811 PROFILE FASTENER PATTERN FIELD SPACING @ 16" O.C. PERIMETER SPACING @ 12" O.C. ZONE Z GMLE ROOF A, Igo" x ZONE I ZONE 3 WE EAVE