HomeMy WebLinkAboutENCODEEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 78/13/2020 1:03 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
JUAN AND JESSICA QUINTEROS
QUINTEROS RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL ,
4637 S. HEADER CANAL ROAD
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
2813
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.65 213.33 ft²
SHGC=0.21
Sgl, U=0.32 100.00 ft²
SHGC=0.21
Sgl, U=0.32 45.00 ft²
SHGC=0.19
other (see details)39.00 ft²
other (see details)
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2813.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 2571.30 ft²
b. Frame - Wood, Adjacent R=13.0 684.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Roof Deck (Unvented)R=20.0 2813.00 ft²
117.00 ft² R=20.0b. Knee Wall (Unvented)
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:12.076 ft.
Area Weighted Average SHGC:0.209
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
3
(397.3 sqft.)
(3255.3 sqft.)
(2930.0 sqft.)
(2813.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
46.5 SEER:16.00
Efficiency
k B t u / h r Efficiency
34.0 COP:1.00
f t ² R
6 200
EF: 0.980
Glass/Floor Area: 0.141
Total Proposed Modified Loads:
Total Baseline Loads:
89.67
95.60 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
9-14-2020
9-14-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
1
JUAN AND JESSICA QUINTE
QUINTEROS RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
2813
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
4637 S. HEADER CANA
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2813 32108
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 GAME RM TOILET 42 420 No 0 Yes Yes1 Yes
2 GAME RM 357 4284 No 0 Yes Yes1 Yes
3 BATH 2 55 550 No 0 Yes Yes1 Yes
4 BEDROOM 3 204 2040 No 0 1 Yes Yes1 Yes
5 WIC 2 36 360 No 0 Yes Yes1 No
6 WIC 3 42 420 No 0 Yes Yes1 Yes
7 BEDROOM 2 209 2090 No 0 1 Yes Yes1 Yes
8 HALL 40 400 No 0 Yes Yes1 No
9 FOYER 135 1890 No 0 Yes Yes1 Yes
10 LIVING RM 418 5852 No 0 Yes Yes1 Yes
11 PANTRY 20 200 No 0 Yes Yes1 No
12 KITCHEN 263 3682 Yes 0 Yes Yes1 No
13 DEN 157 1570 No 0 Yes Yes1 Yes
14 DEN CLST 16 160 No 0 Yes Yes1 No
15 DINING 94 940 No 0 Yes Yes1 Yes
16 M HALL 24 240 No 0 Yes Yes1 No
17 UTILITY RM 88 880 No 0 Yes Yes1 No
18 MASTER BEDROO 263 2630 No 0 1 Yes Yes1 Yes
19 M WIC 140 1400 No 0 Yes Yes1 Yes
20 M BATH 182 1820 No 0 Yes Yes1 Yes
21 M TOILET 28 280 No 0 Yes Yes1 Yes
8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 42 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -013 ft GAME RM TOILE
2 357 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -027 ft GAME RM
3 55 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2
4 204 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -031 ft BEDROOM 3
5 36 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft WIC 2
6 42 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -08 ft WIC 3
7 209 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014.6 ft BEDROOM 2
8 40 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL
9 135 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -09 ft FOYER
10 418 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -022 ft LIVING RM
11 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft PANTRY
12 263 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft KITCHEN
13 157 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014.6 ft DEN
14 16 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft DEN CLST
15 94 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -021 ft DINING
16 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M HALL
17 88 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft UTILITY RM
18 263 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -032 ft MASTER BEDRO
19 140 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -024 ft M WIC
20 182 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft M BATH
21 28 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft M TOILET
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Metal 3146 ft² Light 0.3 20 26.6______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 2813 ft² N N0
8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 42 ft² 0.1 Wood______GAME RM TOILE Blown
2 Under Attic (Unvented)0 357 ft² 0.1 Wood______GAME RM Blown
3 Under Attic (Unvented)0 55 ft² 0.1 Wood______BATH 2 Blown
4 Under Attic (Unvented)0 204 ft² 0.1 Wood______BEDROOM 3 Blown
5 Under Attic (Unvented)0 36 ft² 0.1 Wood______WIC 2 Blown
6 Under Attic (Unvented)0 42 ft² 0.1 Wood______WIC 3 Blown
7 Under Attic (Unvented)0 209 ft² 0.1 Wood______BEDROOM 2 Blown
8 Under Attic (Unvented)0 40 ft² 0.1 Wood______HALL Blown
9 Under Attic (Unvented)0 135 ft² 0.1 Wood______FOYER Blown
10 Under Attic (Unvented)0 418 ft² 0.1 Wood______LIVING RM Blown
11 Under Attic (Unvented)0 20 ft² 0.1 Wood______PANTRY Blown
12 Under Attic (Unvented)0 263 ft² 0.1 Wood______KITCHEN Blown
13 Under Attic (Unvented)0 157 ft² 0.1 Wood______DEN Blown
14 Under Attic (Unvented)0 16 ft² 0.1 Wood______DEN CLST Blown
15 Under Attic (Unvented)0 94 ft² 0.1 Wood______DINING Blown
16 Under Attic (Unvented)0 24 ft² 0.1 Wood______M HALL Blown
17 Under Attic (Unvented)0 88 ft² 0.1 Wood______UTILITY RM Blown
18 Under Attic (Unvented)0 263 ft² 0.1 Wood______MASTER BEDRO Blown
19 Under Attic (Unvented)0 140 ft² 0.1 Wood______M WIC Blown
20 Under Attic (Unvented)0 182 ft² 0.1 Wood______M BATH Blown
21 Under Attic (Unvented)0 28 ft² 0.1 Wood______M TOILET Blown
22 Knee Wall (Unvented)20 30 ft² 0.11 Wood______LIVING RM Blown
23 Knee Wall (Unvented)20 31.5 ft² 0.11 Wood______DINING Blown
24 Knee Wall (Unvented)20 19.5 ft² 0.11 Wood______DEN Blown
25 Knee Wall (Unvented)20 12 ft² 0.11 Wood______FOYER Blown
26 Knee Wall (Unvented)20 19.5 ft² 0.11 Wood______BEDROOM 2 Blown
27 Knee Wall (Unvented)20 4.5 ft² 0.11 Wood______WIC 3 Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0GAME RM T 0007 10S Concrete Block - Int Insul 0.30Exterior70.0 ft² ____
2 4.1 0GAME RM T 0006 10W Concrete Block - Int Insul 0.30Exterior60.0 ft² ____
3 4.1 0GAME RM 00012 12S Concrete Block - Int Insul 0.30Exterior144.0 ft² ____
4 4.1 0GAME RM 00015 12W Concrete Block - Int Insul 0.30Exterior180.0 ft² ____
5 4.1 0BATH 2 0005 10S Concrete Block - Int Insul 0.30Exterior50.0 ft² ____
6 4.1 0BEDROOM 3 0002 10N Concrete Block - Int Insul 0.30Exterior20.0 ft² ____
7 4.1 0BEDROOM 3 00015 10E Concrete Block - Int Insul 0.30Exterior150.0 ft² ____
8 4.1 0BEDROOM 3 00014 10S Concrete Block - Int Insul 0.30Exterior140.0 ft² ____
9 4.1 0WIC 3 0002 10N Concrete Block - Int Insul 0.30Exterior20.0 ft² ____
10 4.1 0WIC 3 0006 10E Concrete Block - Int Insul 0.30Exterior60.0 ft² ____
11 4.1 0BEDROOM 2 00102 10NE Concrete Block - Int Insul 0.30Exterior28.3 ft² ____
12 4.1 0BEDROOM 2 0009 10E Concrete Block - Int Insul 0.30Exterior90.0 ft² ____
13 4.1 0BEDROOM 2 00102 10SE Concrete Block - Int Insul 0.30Exterior28.3 ft² ____
8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
14 4.1 0FOYER0009 14E Concrete Block - Int Insul 0.30Exterior126.0 ft² ____
15 4.1 0LIVING RM 00022 14W Concrete Block - Int Insul 0.30Exterior308.0 ft² ____
16 13 0KITCHEN00021 14N Frame - Wood 0.30.1Garage294.0 ft² ____
17 4.1 0DEN00102 10NE Concrete Block - Int Insul 0.30Exterior28.3 ft² ____
18 4.1 0DEN0009 10E Concrete Block - Int Insul 0.30Exterior90.0 ft² ____
19 4.1 0DEN00102 10SE Concrete Block - Int Insul 0.30Exterior28.3 ft² ____
20 13 0DEN00011 10N Frame - Wood 0.30.1Garage110.0 ft² ____
21 13 0DEN CLST 0002 10N Frame - Wood 0.30.1Garage20.0 ft² ____
22 4.1 0DINING0008 10S Concrete Block - Int Insul 0.30Exterior80.0 ft² ____
23 4.1 0DINING00013 10W Concrete Block - Int Insul 0.30Exterior130.0 ft² ____
24 13 0M HALL 0004 10E Frame - Wood 0.30.1Garage40.0 ft² ____
25 13 0UTILITY RM 00011 10E Frame - Wood 0.30.1Garage110.0 ft² ____
26 4.1 0MASTER BE 00017 10S Concrete Block - Int Insul 0.30Exterior170.0 ft² ____
27 4.1 0MASTER BE 00015 10W Concrete Block - Int Insul 0.30Exterior150.0 ft² ____
28 4.1 0M WIC 00010 10N Concrete Block - Int Insul 0.30Exterior100.0 ft² ____
29 4.1 0M WIC 00014 10W Concrete Block - Int Insul 0.30Exterior140.0 ft² ____
30 4.1 0M BATH 00011 10N Concrete Block - Int Insul 0.30Exterior110.0 ft² ____
31 13 0M BATH 0007 10E Frame - Wood 0.30.1Garage70.0 ft² ____
32 4.1 0M TOILET 0004 10N Concrete Block - Int Insul 0.30Exterior40.0 ft² ____
33 4.1 0M TOILET 0003 10E Concrete Block - Int Insul 0.30Exterior30.0 ft² ____
34 13 0M TOILET 0004 10E Frame - Wood 0.30.1Garage40.0 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 W Low-E Single 0.65 0.21 53.3 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes4 Y
2 S Low-E Single 0.29 0.22 4.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______Yes5 Y
3 E Low-E Single 0.32 0.21 20.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______Yes7 Y
4 NE Low-E Single 0.32 0.19 5.8 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______Yes11 Y
5 E Low-E Single 0.32 0.21 20.0 ft² 10 ft 0 in 1 ft 4 in NoneVinyl None______Yes12 Y
6 SE Low-E Single 0.32 0.19 5.8 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______Yes13 Y
7 E Low-E Single 0.65 0.21 40.0 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______Yes14 Y
8 W Low-E Single 0.3 0.22 21.7 ft² 22 ft 0 in 1 ft 4 in Drapes/blindsVinyl Exterior 5______Yes15 Y
9 W Low-E Single 0.65 0.21 80.0 ft² 22 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes15 Y
10 NE Low-E Single 0.32 0.19 5.8 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______Yes17 Y
11 E Low-E Single 0.32 0.21 20.0 ft² 10 ft 0 in 1 f t 4 in NoneVinyl None______Yes18 Y
12 SE Low-E Single 0.32 0.19 5.8 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______Yes19 Y
13 S Low-E Single 0.32 0.19 21.7 ft² 20 ft 0 in 1 f t 4 in Drapes/blindsVinyl Exterior 5______Yes22 Y
14 W Low-E Single 0.32 0.21 40.0 ft² 14 ft 0 in 1 f t 4 in Drapes/blindsVinyl Exterior 5______Yes23 Y
15 S Low-E Single 0.65 0.21 40.0 ft² 10 ft 0 in 1 f t 4 in NoneMetal None______Yes26 Y
16 W Low-E Single 0.29 0.22 8.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______Yes27 Y
17 N Low-E Single 0.29 0.22 5.3 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______Yes30 Y
8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 988 ft² 988 ft² 60 ft 10 ft 13______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
2675.7 5146.89.000363Wholehouse .1449276.25Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 34 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 46.5 kBtu/hr 1395 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 200 ft² Attic 20 ft² Default Leakage Attic (Default) c______1 1 (Default) c
8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 M HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 W/D
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 AHU CLST
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 1
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 1
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 1
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER/LIVING
8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������