Loading...
HomeMy WebLinkAboutENCODEEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 78/13/2020 1:03 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY JUAN AND JESSICA QUINTEROS QUINTEROS RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , 4637 S. HEADER CANAL ROAD Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 2813 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 213.33 ft² SHGC=0.21 Sgl, U=0.32 100.00 ft² SHGC=0.21 Sgl, U=0.32 45.00 ft² SHGC=0.19 other (see details)39.00 ft² other (see details) 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2813.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 2571.30 ft² b. Frame - Wood, Adjacent R=13.0 684.00 ft² c. N/A R=f t ² 10. Ceiling Types a. Roof Deck (Unvented)R=20.0 2813.00 ft² 117.00 ft² R=20.0b. Knee Wall (Unvented) c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:12.076 ft. Area Weighted Average SHGC:0.209 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 3 (397.3 sqft.) (3255.3 sqft.) (2930.0 sqft.) (2813.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 46.5 SEER:16.00 Efficiency k B t u / h r Efficiency 34.0 COP:1.00 f t ² R 6 200 EF: 0.980 Glass/Floor Area: 0.141 Total Proposed Modified Loads: Total Baseline Loads: 89.67 95.60 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 9-14-2020 9-14-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY 1 JUAN AND JESSICA QUINTE QUINTEROS RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 2813 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FORT PIERCE , St. Lucie 4637 S. HEADER CANA Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2813 32108 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 GAME RM TOILET 42 420 No 0 Yes Yes1 Yes 2 GAME RM 357 4284 No 0 Yes Yes1 Yes 3 BATH 2 55 550 No 0 Yes Yes1 Yes 4 BEDROOM 3 204 2040 No 0 1 Yes Yes1 Yes 5 WIC 2 36 360 No 0 Yes Yes1 No 6 WIC 3 42 420 No 0 Yes Yes1 Yes 7 BEDROOM 2 209 2090 No 0 1 Yes Yes1 Yes 8 HALL 40 400 No 0 Yes Yes1 No 9 FOYER 135 1890 No 0 Yes Yes1 Yes 10 LIVING RM 418 5852 No 0 Yes Yes1 Yes 11 PANTRY 20 200 No 0 Yes Yes1 No 12 KITCHEN 263 3682 Yes 0 Yes Yes1 No 13 DEN 157 1570 No 0 Yes Yes1 Yes 14 DEN CLST 16 160 No 0 Yes Yes1 No 15 DINING 94 940 No 0 Yes Yes1 Yes 16 M HALL 24 240 No 0 Yes Yes1 No 17 UTILITY RM 88 880 No 0 Yes Yes1 No 18 MASTER BEDROO 263 2630 No 0 1 Yes Yes1 Yes 19 M WIC 140 1400 No 0 Yes Yes1 Yes 20 M BATH 182 1820 No 0 Yes Yes1 Yes 21 M TOILET 28 280 No 0 Yes Yes1 Yes 8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 42 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -013 ft GAME RM TOILE 2 357 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -027 ft GAME RM 3 55 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2 4 204 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -031 ft BEDROOM 3 5 36 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft WIC 2 6 42 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -08 ft WIC 3 7 209 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014.6 ft BEDROOM 2 8 40 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 9 135 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -09 ft FOYER 10 418 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -022 ft LIVING RM 11 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft PANTRY 12 263 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft KITCHEN 13 157 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014.6 ft DEN 14 16 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft DEN CLST 15 94 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -021 ft DINING 16 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M HALL 17 88 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft UTILITY RM 18 263 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -032 ft MASTER BEDRO 19 140 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -024 ft M WIC 20 182 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft M BATH 21 28 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft M TOILET # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 3146 ft² Light 0.3 20 26.6______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 2813 ft² N N0 8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 42 ft² 0.1 Wood______GAME RM TOILE Blown 2 Under Attic (Unvented)0 357 ft² 0.1 Wood______GAME RM Blown 3 Under Attic (Unvented)0 55 ft² 0.1 Wood______BATH 2 Blown 4 Under Attic (Unvented)0 204 ft² 0.1 Wood______BEDROOM 3 Blown 5 Under Attic (Unvented)0 36 ft² 0.1 Wood______WIC 2 Blown 6 Under Attic (Unvented)0 42 ft² 0.1 Wood______WIC 3 Blown 7 Under Attic (Unvented)0 209 ft² 0.1 Wood______BEDROOM 2 Blown 8 Under Attic (Unvented)0 40 ft² 0.1 Wood______HALL Blown 9 Under Attic (Unvented)0 135 ft² 0.1 Wood______FOYER Blown 10 Under Attic (Unvented)0 418 ft² 0.1 Wood______LIVING RM Blown 11 Under Attic (Unvented)0 20 ft² 0.1 Wood______PANTRY Blown 12 Under Attic (Unvented)0 263 ft² 0.1 Wood______KITCHEN Blown 13 Under Attic (Unvented)0 157 ft² 0.1 Wood______DEN Blown 14 Under Attic (Unvented)0 16 ft² 0.1 Wood______DEN CLST Blown 15 Under Attic (Unvented)0 94 ft² 0.1 Wood______DINING Blown 16 Under Attic (Unvented)0 24 ft² 0.1 Wood______M HALL Blown 17 Under Attic (Unvented)0 88 ft² 0.1 Wood______UTILITY RM Blown 18 Under Attic (Unvented)0 263 ft² 0.1 Wood______MASTER BEDRO Blown 19 Under Attic (Unvented)0 140 ft² 0.1 Wood______M WIC Blown 20 Under Attic (Unvented)0 182 ft² 0.1 Wood______M BATH Blown 21 Under Attic (Unvented)0 28 ft² 0.1 Wood______M TOILET Blown 22 Knee Wall (Unvented)20 30 ft² 0.11 Wood______LIVING RM Blown 23 Knee Wall (Unvented)20 31.5 ft² 0.11 Wood______DINING Blown 24 Knee Wall (Unvented)20 19.5 ft² 0.11 Wood______DEN Blown 25 Knee Wall (Unvented)20 12 ft² 0.11 Wood______FOYER Blown 26 Knee Wall (Unvented)20 19.5 ft² 0.11 Wood______BEDROOM 2 Blown 27 Knee Wall (Unvented)20 4.5 ft² 0.11 Wood______WIC 3 Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0GAME RM T 0007 10S Concrete Block - Int Insul 0.30Exterior70.0 ft² ____ 2 4.1 0GAME RM T 0006 10W Concrete Block - Int Insul 0.30Exterior60.0 ft² ____ 3 4.1 0GAME RM 00012 12S Concrete Block - Int Insul 0.30Exterior144.0 ft² ____ 4 4.1 0GAME RM 00015 12W Concrete Block - Int Insul 0.30Exterior180.0 ft² ____ 5 4.1 0BATH 2 0005 10S Concrete Block - Int Insul 0.30Exterior50.0 ft² ____ 6 4.1 0BEDROOM 3 0002 10N Concrete Block - Int Insul 0.30Exterior20.0 ft² ____ 7 4.1 0BEDROOM 3 00015 10E Concrete Block - Int Insul 0.30Exterior150.0 ft² ____ 8 4.1 0BEDROOM 3 00014 10S Concrete Block - Int Insul 0.30Exterior140.0 ft² ____ 9 4.1 0WIC 3 0002 10N Concrete Block - Int Insul 0.30Exterior20.0 ft² ____ 10 4.1 0WIC 3 0006 10E Concrete Block - Int Insul 0.30Exterior60.0 ft² ____ 11 4.1 0BEDROOM 2 00102 10NE Concrete Block - Int Insul 0.30Exterior28.3 ft² ____ 12 4.1 0BEDROOM 2 0009 10E Concrete Block - Int Insul 0.30Exterior90.0 ft² ____ 13 4.1 0BEDROOM 2 00102 10SE Concrete Block - Int Insul 0.30Exterior28.3 ft² ____ 8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 14 4.1 0FOYER0009 14E Concrete Block - Int Insul 0.30Exterior126.0 ft² ____ 15 4.1 0LIVING RM 00022 14W Concrete Block - Int Insul 0.30Exterior308.0 ft² ____ 16 13 0KITCHEN00021 14N Frame - Wood 0.30.1Garage294.0 ft² ____ 17 4.1 0DEN00102 10NE Concrete Block - Int Insul 0.30Exterior28.3 ft² ____ 18 4.1 0DEN0009 10E Concrete Block - Int Insul 0.30Exterior90.0 ft² ____ 19 4.1 0DEN00102 10SE Concrete Block - Int Insul 0.30Exterior28.3 ft² ____ 20 13 0DEN00011 10N Frame - Wood 0.30.1Garage110.0 ft² ____ 21 13 0DEN CLST 0002 10N Frame - Wood 0.30.1Garage20.0 ft² ____ 22 4.1 0DINING0008 10S Concrete Block - Int Insul 0.30Exterior80.0 ft² ____ 23 4.1 0DINING00013 10W Concrete Block - Int Insul 0.30Exterior130.0 ft² ____ 24 13 0M HALL 0004 10E Frame - Wood 0.30.1Garage40.0 ft² ____ 25 13 0UTILITY RM 00011 10E Frame - Wood 0.30.1Garage110.0 ft² ____ 26 4.1 0MASTER BE 00017 10S Concrete Block - Int Insul 0.30Exterior170.0 ft² ____ 27 4.1 0MASTER BE 00015 10W Concrete Block - Int Insul 0.30Exterior150.0 ft² ____ 28 4.1 0M WIC 00010 10N Concrete Block - Int Insul 0.30Exterior100.0 ft² ____ 29 4.1 0M WIC 00014 10W Concrete Block - Int Insul 0.30Exterior140.0 ft² ____ 30 4.1 0M BATH 00011 10N Concrete Block - Int Insul 0.30Exterior110.0 ft² ____ 31 13 0M BATH 0007 10E Frame - Wood 0.30.1Garage70.0 ft² ____ 32 4.1 0M TOILET 0004 10N Concrete Block - Int Insul 0.30Exterior40.0 ft² ____ 33 4.1 0M TOILET 0003 10E Concrete Block - Int Insul 0.30Exterior30.0 ft² ____ 34 13 0M TOILET 0004 10E Frame - Wood 0.30.1Garage40.0 ft² ____ # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 W Low-E Single 0.65 0.21 53.3 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes4 Y 2 S Low-E Single 0.29 0.22 4.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______Yes5 Y 3 E Low-E Single 0.32 0.21 20.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______Yes7 Y 4 NE Low-E Single 0.32 0.19 5.8 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______Yes11 Y 5 E Low-E Single 0.32 0.21 20.0 ft² 10 ft 0 in 1 ft 4 in NoneVinyl None______Yes12 Y 6 SE Low-E Single 0.32 0.19 5.8 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______Yes13 Y 7 E Low-E Single 0.65 0.21 40.0 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______Yes14 Y 8 W Low-E Single 0.3 0.22 21.7 ft² 22 ft 0 in 1 ft 4 in Drapes/blindsVinyl Exterior 5______Yes15 Y 9 W Low-E Single 0.65 0.21 80.0 ft² 22 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes15 Y 10 NE Low-E Single 0.32 0.19 5.8 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______Yes17 Y 11 E Low-E Single 0.32 0.21 20.0 ft² 10 ft 0 in 1 f t 4 in NoneVinyl None______Yes18 Y 12 SE Low-E Single 0.32 0.19 5.8 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______Yes19 Y 13 S Low-E Single 0.32 0.19 21.7 ft² 20 ft 0 in 1 f t 4 in Drapes/blindsVinyl Exterior 5______Yes22 Y 14 W Low-E Single 0.32 0.21 40.0 ft² 14 ft 0 in 1 f t 4 in Drapes/blindsVinyl Exterior 5______Yes23 Y 15 S Low-E Single 0.65 0.21 40.0 ft² 10 ft 0 in 1 f t 4 in NoneMetal None______Yes26 Y 16 W Low-E Single 0.29 0.22 8.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______Yes27 Y 17 N Low-E Single 0.29 0.22 5.3 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______Yes30 Y 8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 988 ft² 988 ft² 60 ft 10 ft 13______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 2675.7 5146.89.000363Wholehouse .1449276.25Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 34 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 46.5 kBtu/hr 1395 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 200 ft² Attic 20 ft² Default Leakage Attic (Default) c______1 1 (Default) c 8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 M HALL Default(8 lbs/sq.ft.f t ² f t 0.3 W/D Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC Default(8 lbs/sq.ft.f t ² f t 0.3 AHU CLST Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 1 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 1 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 1 Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER/LIVING 8/13/2020 1:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������