Loading...
HomeMy WebLinkAboutField & Laboratory ReportUES Project No.: 0310.1700251.0064 UNIVERSAL Date Typed: December 17, 2019 t- GINErE.R;ING -S: -M.N;C:ES consultants lri: Geotiechnicalfikgineenng efnvironmentaPSdences Geophysical Services •-Materials'Testitig; a Threshold Inspection Building.Code Administration, Complianceanspection.&Plan Review 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE Client: Ryan Homes L �Gc�e�Ppa,� 1450 Centrepark Blvd Suite 340 1 u 5' O S I °01�fy�e�t West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 39 Permit 1905-0548 5226 Oakland Lake Circle, Ft. Pierce, St. Lucie County, FL As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or field inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summarized below: Scope of Work Work Order No. Date Type of Report 114529-1 1 08/21/2019 In -Place Density Test Report w/Activity Record We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned. Sincerely, Universal Engineering Sciences, Inc. Certificate of Authorization" No. 00000549 Richard E. Hoaglin, P.E. FLORIDA Professional Engineer No. 48796 ICC Email: cbugg@nvrinc.com; rhager@nvrinc.com; rlingar@nvr.com; sign/seal MAIL to ryan homes at 5369 Oakland Lake, Ft. Pierce, FL 32941 planreview@stiucieco.org UES Prof"" t ,;go: 0310.1700261.0064 �_ _ UES DOCS No: S A�_� _ UES Report No: 114529 1 ARC 082119 ENGINEERING _SCIENCES On -Site Time (hrs): 0.50 Ccnsuli:ants:In-.Geotechnical Engineering,-�'Environmental.Sciences Lab Time (hrs): 0.00 GeophysicahServices ••Materiais,Testing iThresholdanspection Travel Time (hrs): 1.25 Building Code>Administration CompliangkInspection & Plan Review Total Time (hrs): 1.75 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 Activity Record Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 39 Permit 1905-0548 5226 Oakland Lake Circle, Ft. Pierce, St. Lucie County, FL Date of Activity: Wednesday, 21 August, 2019 Technician: . Russell Brause As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of earthwork testing for the House pad # 39. While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House pad # 39.. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the project compaction requirements of 95% of the maximum dry density per ASTM D-1557. The Contractor was notified of the test results or a copy was left for their records. Project No: 0310.1700251.0064 UNIV. S A L UUES ES DOCS No ED UES Report No: 114529-1 DT 082119 ,ENGI.N_EERI.NGSCENC;ES Consultants In-.- ¢al Egen-epionmentalSciences:iinn Geophysical,Sety' tes • MaterialsTesting i Threshold'inspection: Building Code.Administrati6n; Compliance:lnspeetion &Plan Review 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 In -Place Density Test Report Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 39 Permit 1905-0548 5226 Oakland Lake Circle, Ft. Pierce, St. Lucie County, FL Area Tested: House pad # 39. Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 08/21/2019 Lab: ASTM D1557 Modified Proctor Technician: Russell Brause Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions only and do not address the condition of the underlying soils below the tested depths. Test No. Location of Test Range Depth (inch) Proctor (2) Field Dry Density (PCF) Field Moisture % % Compaction Comments (3) 1 NW corner. 0 to -1 ft 12.00 21143 111.6 11.2 97 A 2 SW corner. 0 to -1 ft 12.00 21143 114.2 12.0 99 A 3 NE corner. 0 to -1 ft 12.00 21143 114.0 12.1 99 A 4 SE corner. 0 to -1 ft 12.00 21143 113.8 1 12.0 99 A (1) Ref. Datum: 0 = Top of Final Grade (2) Maximum Optimum Proctor Dry Moisture # Density Content 21143 115.0 12.0 This test was performed without deviation from ASTM procedures. (3) Comments Key A. Compaction meets min. requirements B. Compaction does not meet min. requirements C. Moisture does not meet requirements D. Recompaction required E. Recompacted, Retested, Meets Requirements This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.