Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
-+ + wrightsoft® Project Summary Entire House One Stop Cooling and Heating 7225 Sandscove Court, Winter. Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wwwOneStopCooling.com License: CAC032444 Project• • For. Ryan Homes Ft Pierce, FL Notes: Job: Lot 039 F1452 B LHG - W Date: 7/11119 .By: WW Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 68 OF Inside db 74 OF Design TD 26 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 64 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 15406 Btuh Structure 14191 Btuh Ducts 2627 Btuh Ducts 2837 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower. 0 Btuh Piping 0 Btuh Equipment load 18032 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 16176 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2894 Btuh Ducts 738 Btuh Central vent (0 eft) 0 Btuh Heatingg Cooling (none) Area (ft�) 1453 1453 Equipment latent load 3632 Btuh Volume (ft) 12639 12639 Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 19808 Btuh Equiv AVF (cfm) 95 48 Req. total capacity at 0.75 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfgg. Make Goodman Mfgg. Trade GOODMAN; JANITROL; AMANA DISTI... Trade GOODMAN; JANITROL; AMANA DISTI... Model GSZ140241 K Cond GSZ140241 K AHRI ref 7995055 Coil ARUF25B14A AHRI ref 7995055 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heating Input Sensible cooling 17400 Btuh Heating output 23200 Btuh @470F Latentcooling 5800 Btuh Temperature rise 27 OF Total cooling 23200 Btuh Actual airflow 773 cfm Actual airflow 773 cfm Airflowfactor 0.043 cfm/Btuh Airflowfactor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Capacity balance point= 36 OF Backup: Input = 9 kW, Output = 29982 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 41- wrlgto hsft® 2019-Jul-11,09:20:30 Right -Suite® Universal 2019 19.0.04 RSU21856 Page 1 ACCA...Lot SpecifidLot39\Lot039F1452BLHG-W.rup Calc=MJ8 FrontDoorfaces: W wrightsoftRight-MWorksheet Job: Lot039F1452BLHG-W Entire House Date: 7119/19 By:: W W One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax,, (407) 629 - 9307 Web: wmwOneStopCooling.com License: CAC032444 1 Room name Entire House DIN 2 Exoosed wall 146.0 ft 20.5 ft 3 Room height 8.7 ft d 8.7 ft heat/cool 4 Room dimensions 11.0 x 9.5 ft 5 Room area 1452.8 ftz 104.5 ftz Ty ConsUudion U-value Or HTM Area (ftz. Load Area (ft') Load number (Btuhfit-°F) (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 yU�JI 13A flocs 13A-4ocs 0.143 0540 0.143 n _ n, a 372 '-1,4(4 .3.72 2.33 _ _ 13.57 2.33 413 ,._.16 183 397 ._ .., .0 146 1476 :....._ 229 544 925 .. y 222 341 83 0 83 0 307 0 193 0 0 W 4A5-20b 0.540 a 14.04 34.61 16 0 229 566 0 0 0 0 11 11D0 13A flats 0.390 0143 _0540 a s _ws 10.14 3 72 1�09 10.72 233_ _ 1357 20 326 _ 16 20 310 __. _ __.,_33 204 1152 _2.29 216 722 222 0 0 : 0__. 0 , 0 Q 0 0 �_�� 0 0 ..___ yJ IW 13A-4ocs 0.143 w 3.72 2.33 348 265 987 619 96 62 231 145 I-v 4A5-2ob 0.540 w 14.04 34.61 49 0 688 1697 0 0 0 0 I� C 4A5-2obd 12C.0sw '° 11D0 - 168-30ad . 0.630 0091 _._0;390 0.032 w n.,1014 16.38 2.37 0.83 36.89 115 .,. 1072 . 1.63 34 252 16 1453 0 236 , _ 16 1453 549 559 .., _- __162 1209 1236 274 :. _' ..,172 - 2371 . 34 .' 0 . - 0 105 0 0 105 549 0 87 1236 g 0 -- .... 0 171 22A-cpm :,: 1.180 _ :-;.'_..30.68: _ _0:00 1g53 146 `.4479 .__. _ 0 :--w__ 105 .._.. _2 _:m:_ .629 77 7.1 r 6 o)AED excursion 1141 572 Envelopeloss/gain 12697 10719 1803 2316 12 a) Infiltration 2709 852 380 120 b) Room ventilation 0 0 0 0 13 Internal gains Occupants@ 230 4 '920 0 0 Applianoes/other .1700 0 Subtotal (lines 6 to 13) 15406 14191 2183 2435 Less extemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution •0 0 0 0 14 Subtotal 15406 14191 2183 2435 15 DUdloadS 17% 20% 2627 2837 17% 20% 372 487 Total room load 18032 17027 F2556 2922 Air required (cfim) 773 773 110 133 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. Ad- .wrYgFftsof :1 Mg-Jul-11 09:20:30 Right -Suite® Universal 2019 19.0.04 RSU21856 Page 1 �`...LotSpecificlot391Lot039F1452BLHG-W,rup CaIc=MJ8 FrontDoortaces: W wrightsoft Right-M.Worksheet Job: Lot 039 F1 452 B LHG-W 11/19 Entire House Date` By: WIN One Stop Cooling and Heating 7225 Sandscove Court, Winter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wAAmOneStopCooling.com License: CAC032444 1 Room name GREAT MBED 2 Exposed wall 14.0 it 30.0: ft 3 Room height 8.7 ft heat/cool 8.7 ft heat/ocol 4 Room dimensions 1.0 x . 298.0 ft 1.0 x 227.0 ft 5 Room area 298.0 ftz 227.0 ft' Ty Construction U-value Or HTM Area (ftz) Load Area (ft-) Load number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 UU. 13A flocs s 13A-4ocs 0143 0.143 r a 372 3.72 2 33 2.33 + 0 0 0 0 0 0 µ 0 4_0 0 0. 0 D : _. _ 0 0 0 0 0 a 0 0 0 W 4A5-2ob 0.540 - e 14.04 34.61 0 0 0 0 0 0 0 0 11 11DO 13A flocs 4A5-2ob._.__.. _. 13A-4ocs 0.390 0143 `_ ._,__0540 0.143 a S _ s_, w 10.14 3 72 __1404 3.72 10.72 • 2 33 1357 2.33 0 0 .__� _,_0 122 0 0 _ .._ 0 89 0 0 .�.;u.__0 331 0 4 0 --_-_. 208 0 _ 931 __._ _ 16 131 0 914 .___ :._ 16 114 0 424 __._� 229 424 0 2fi6, 266 IW I--(; 4A5.2ob 0.540 w 14.04 34.61 33 0 459 1131 16 0 229 566 L—G C 4A5-2obd 12C-Osvv 16B-30ad 0.630 0091 390 0.032 w n, , 16.38 2.37 1614, 0.83 36.89 115 _ _ 10 Z2 1.63 0 0 __ . _ ,-0 298 0 0 298 0 „ >0 248 0 0 � 486 0 0 _m .._ _, .._ 0 227 0 6 .227 0 0 189 0 0 370 F::. , • 22A cpm. _s. a, ..1 180 _30 68 0:00 ._ 29,8_.227 . _ _. '-30 _920 ":... ,.t ... .. __. -.. c_.__........___.,..,: _'., ., .,_..i;._-L tid u..a tea__.._._; ....s �.,_t _,_ ... _.<- - .. _i:.. _,....s .t. .�..._<..__ .......,:..u. m..... i.�. .-_. ..-._.5'✓ _..� ...... .__-_...._ .......__ _• 6 c)AEDexcursion 537 129 Ernelopeloss/gain 1468 2362 2417 1819 12 a) Infiltration 260 . 82 557 175 b) Room ventilation 0 0 0 0 13 Internal gains Ooarpants@ 230 0 0 2 460 Appliancesrother 0 0 Subtotal (lines 6 to 13) 1727 2443 2974 2455 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 -Redistribution 200 311 0 0 14 Subtotal 1927 ' 2755 2974 2455 15 Dud loads 17% 20% 329 551 17% 20% 907 491 Total room load 2256 3306 3481 .2945 Air required (cim) 97 150 149 134 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -r- wrIgtftsoft- 2019-JUI-11 09:20:30 .4CCA �^ ate• Right-SuiteOUniversa1201919.0.04RSU21856 Page Lot Specifi&ot Wl-ot 039 F1452 B LHG - W.rup Calc= MJ8 Front Doorfaces: W - 1-wrightsoft° Right @WorkSheet Job: Lot 039F1452BLHG-W EDate: 7/11119 ntire House ww One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wwvOneStopCooling.com License: CAC932444 1 Room name IQT PAN. 2 FVosed wall 9.0 ft 4.0. ft 3 Room height 8.7 ft heat/cool 8.7 ft heaUcool 4 Room dimensions 1.0. x 126.1 ft 1.0 x 16.9 ft- 5 Room area 126.1 ftz 16.9 ftz Ty . Con4uction U-value Or HTM Area (ftz Load Area , (ft- Load number (Btuh/t;°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1//J 13A flats ', 0143 n 3 Z2 2.33 78 78 291 183 35 35 129 81 -Ir., G- 4A5 tab 0 540 _n; _ r 14 04 . ._13 57 0 _.._ . ; . 0 - r,, 0 - 0 . -:u ._ _. __A _ . A _ _0 0 W 13A-4ocs 0.143 a 3.72 2.33 0 0 0 0 .0 0 0 0 4A5.2ob 0.540 a 14.04 34.61 0 0 0 0 0 0 0 0 11 11 DO ' 0.390 a 10.14 10.72 0 0 0 0 0 0 0 0 1!N 13A flocs O'143 s 'i 3.72 2 33 0 0 0 0 0 p 0 p _.m0.5401404 _13.57. W 13A4ocs 0.143 w 3.72 2.33 0 0 0 0 0 0 0 0 4A5-2ob 0.540 w 14.04 34.61 0 0 0 0 0 0 0 0 4A5-2obd 6.630 w_ 16.38 36.89 0 0 0 .0 0 0 0 :0 12CJrr 0 091 237 1 15 0 0 0 0 0 0 0 0 .,n,__ 014 10.72 _ _w._ . _,._x_ _. 0 ._. ,:...._0 _ _,.__ ._0 _:._ _,... 0 .0 _ n:. 0 ._� _. __ 0. C 161330ad . 0.032 - 0.83 _ .:1.63 1261. 1I-I26 105 206 17 17 14 28 F 1 180 _:_..:. _ 30.68: 0 00 126 9 276_. _ 4 123 g , _. .; 6 c)AED excursion 62 -5 Envelope loss(gain 672 ' 326 266 104 12 a) Infiltration 167 53 74 23 b) Room ventilation 0 0 0 0 13 Internal gains Occupants@ 230 0 0 0 0 Appliancestother .1200 0 Subtotal Qines6 to 13) 839 1579 1 340 127 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redishribution 3 6 0 0 14 Subtotal 842 1584 340 127 15 Duct leads 17% 20% 144 317 17% 20% 58 25 Total room load 986 .1901 398 152 Air required (dm) 42 86 17 7 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. *-..wr1gtisoR t_m 2019-Jul-11.09:26:30 ACCP� ^-^ K Right Suite® Universal 201919.0.04 RSU21856 Page 3 Lot Specifi6\Lot 39%Lot 039 F1452 B LHG - W.rup Calc-- MJ8 Front Doorfaces: W- wrightsofV Right-J® Worksheet Job: Lot 039 F1452 B LHG - W Entire Hou' se Date: 7/11/19 By: W W - One Stop Cooling and Heating 7225 Sandscove Court, Winter Park FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wwwOneStopCooling.com License: CAC032444 1 Room name MWIC MBTH 2 Eposed wall 0 ft 12.0 ft 3 Room height 8.7 ft heat/000l 8.7 ft heat/000l 4 Room dimensions 8.0 x 7.0 ft . 1.0 x 107.5 . ft 5 Room area 56.0 ftz 107.5 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ft-°F) (Btuh/f?) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11�l w�= -G W 13A 4acs - 4A52ob, _ 13A-4ocs 0.143 0,540 0.143 n _0._ a 3 72 _. 1404 3.72 2 33 ..1357 2.33 0 ._._.. _- _0 0 0 _ .:. 0 0 0 £ 0 0 0- `:. 0 0 0 0 0 0 :_ _.._':0 0 0 .. ...; _0 0 0 0: 0 4A5-2ob 0.540 a 14.04 34.61 0 0 0 0 0 0 0 0 11 11DO 13A flocs 0.390 0.143 a s 10.14 3.72 10.72 233 0 0 0 0 0 0 0 0 0 104 0 104 0 388 0 243 4g52ob_. .: - .. s_.. [._ 14D4 _Y.1357 _ ,____ ..0 - --,_ _:. 0 _..: :_ _...0 _ ` , _ 0 ._ _ ...'_0 W 13A-flocs 0.143 w 3.72 2.33 0 0 0 0 0 0 0 0 4A5-2ob 0.540 w 14.04 34.61 0 0 0 0 0 0 0 0 R ______ . 4A5.2obd 12C-09u 11D0_____e 0.630 0091 0:390 w .._,n 16.38 Y 237 :.-._1014 36.89 1 15 _ _1072 0 70 . 0 0 70 _. Q 0 165 0 0 80 __.' _- 9 0 ' 65 _ .._.._., 0 65 0 0 154 _ ._-, _0 0 75 ---.__, 0. C 16B-30ad 0.032 0.83 1.63 56 56 47 91 108 ___ 108 89 175 _ _. 000 .. -- - _: _ 0 .._.._._. 0 .. _ 0_12 p. 6 o)AED excursion -6 -21 Envelope losstgain 211 165 1000 472 12 a) Infiltration 0 0 223 70 b) Room ventilation 0 0 0 0 13 Internal gains Occupants@ 230 0 0 '0 0 Appliances(other 0 0 Subtotal (lines 6 to 13) 211 165 1223 542 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution "62 369 0 0 14 Subtotal 273 533 1223. 542 15 Dud loads 17% 200/0 47 107 17% 20% 208 108 Total room load FT. 319 640 1 .1431 651 Air required (dm) - ' 14 29 61 30 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -4- 2019-Jul-1109:20:30 .4rCP. ^- - • . Right-Suite®Universal 201919.0.04 RSU21856 Page 4 LotSpecifibLot391Lot039F1452BLHG-Wrup Calc=MJB FrontDoorfaces: W wrightsoft® Right-JOWolrksheet Jab: Lot 039 F1 452 B LHG - W Entire House Date: 7111/19 Etr ww One'Stop Cooling and Heating 7225 Sandsoove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 ' Web: wv vOneStopCooling.com License: CAC032444 1 Room name BTH2' 2 Fposedwall 0 ft. 0: ft 3 Room height 8.7 ft heat/cool 8.7 ft heaU000l 4 Room dimensions 5.5 x 4.0 ft 5.5 .. x 8.5 ft 5 Room area 22.0 ft2 46.8 ft' Ty Construction U-value Or . HTM Area (ft2) Load Area (ft2) Load number (Btuh/t2-'F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1qJ L—G 13A flocs 4A5 2ob....... -:- 13A4ocs O'143 _..____0.5-0 0.143 n .n... a 3.72 ,1404:__ 3.72 2 33 1_357 2.33 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 W 4A5-2ob 0.540 a 14.04 34.61 0 0 0 0 0 0 0 0 11 IW 11DO 13A-4ocs 0.390 0.143 e. w 10.14 3.72 . 10.72 1357, 2.33 0 _. . 0 0 0 0 0 0 0 0 0 _,._ 0 0 0 ^__ __. __0 0- 0 __._ : _;0 0 0 __., 0 0 0 µ,_ __.-:0. 0 I--c� 4A5-2ob 0.540 w 14.04 34.61 0 0 0 0 0 0 0 0 L—G Fj Y '.: C 4A5-2obd 12C 0Sw 1100 __.- _ _ s_ 1613-30ad 0.630 0 091 _.---_0390 0.032 w n - 16.38 237 .__1014 0.83 36.89 1 15 1072 1.63 . 0 _ 0 ..,__ -0 22 0 0 22 0 0 18 0 0 36 0 0 47 0 47 0 39.. 0 76 -qpm „-. _ _ .0 00 F -r ,h 6 c)AED excursion -1 '-3 Envelopelosslgain 18 351 39 73 12 a) infiltration 0 0 0 0 b) Room ventilation 0 0 0 b 13 Internal gains Occupants @ 230 0 0 0 .0 Applianeescother 0 0 Subtotal (lines6 to 13) 18 35 39 - 73 Less exiemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -18 -35 511 369 14 Subtotal 0 0 550 . ' 442 15 DUdloadS 17%0 20% 0 0 179/6 20% 94 88 Total room load : 0 0 644 530 Air required (dm) 01 0 28 24 Calculations approved bviACCA to meet all requirements of Manual J 8th Ed. -�.� .wrtigtitsoit® .2019-Jul-1109:20:30 ^-^- -�- -� Right -Suite® Universal201919.0.04 RSU21856 Page 5 Lot Specific\Lot39\Lot039F1452BLHG-W.rup ,Calc=MJ8 FrontDoorfaces: W, _ wrightsoft° Right-JO Worksheet Job: L1452BLHG-W Entire House 7/11/19 11/19 By: W W One Stop Cooling and Heating 7225 Sandscove Court, Winter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wmmOneStopCooling.00m License: CAC032444 1 Room name LDRY BED3 2 EVosed wall 0 ft 14.0 ft 3 Room height 8.7 ft heattcool 8.7 ft heat/ocol 4 Room dimensions 3.5 x 7.0 ft 11.0 x 14.0 It 5 Room area 24.5 ftz 154.0 ftz Ty Consbuclion U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuhlft-°F) (Btuhlftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 VjJ ' " 13Aocs . 0.143 n 3.72, 233 0 -" 0 0 0 122 105 392 246 I-� _ 4A5lob'-:"--- ---.-_-0.540 "..n.- ---14.04 _ _13.57 -_. :__.gib ..__ ___0 __ -__ 0 -__..-_; -0 -- --- 16 - 0 229 222 W ,_.-"- 13A-4ocs 0.143 a 3.72 2.33 0 0 0 0 0 0 0 0 4A5-2ob 0.540 a 14.04 34.61 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.14 10.72 0 0 0 0 0 0 0 0 _ -_ -- '13A 4as 0143 3. 72 233 0 o 0 _0 _ _. - o _. a •0 0 _4A5-2ob-_L _ -; --- _-.0540 ._ s,- __.1.40-4 -... 1357 ,._. ..._0 ._. _--.. _0 ._ .._ ___0 -..__. _- Q ._ _ _0 -. -. _. _0 -_ - --- - - - - 0. W 13A-flocs 0.143 w 3.72 2.33 0 0 0 0 0. 0 0 0 4A5-26b 0.540 w 14.04 34.61 0 0 0 0 0 0 0 0 4A5 2obd 12C Osw 11D0. __ _..,_.,_ 0.630 O.Q91 .. -0.390 w n__ 16.38 2.37 -_ _1014` 36.89 1.15 ._ 10.72 .. 0 30 - _ - _- D 0 30 ------,-0 0 72 ----_._- �-_0 0 35 0 0 0 0 0 0 .0 0 FFjj ,_D, C 16B-30ad 0.032 0.83 1.63 25 25 20 40 154 154 128 251 F 22Acpm_. _ r . _ ...1180 c.. 306& -0.00 _.... _ 25 _0 -:----- _;0 - •---. -0 _._ 154 _ --_-_.14 _ . :430 -,-- -,0. 6 c)AED excursion -22 -39 Ernelopeloss/gain 92 53 1179 680 12 a) Infiltration 0 0 260 82 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 1 230 Applianceslother 500 0 Subtotal Qines 6 to 13) 92 553 1439 992 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution -92 -553 146 105 14 Subtotal 0 0 1585 1097 15 DUdloads 17% 20% 0 0 17% 20% 270 219 Total room load 0 0 1855 1316 Air required (crm) 0 01 801 60 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -rid- 2019-Jul-11.09:20:30 Right -Suite® Universal 2019 19.0.04 RSU21856 Page 6 ACGA •.,Lot Speclfio\.ot 391Lot 039 F1452 B LHG - Wrup Calc- MJ8 Front Door faces: W -�- wrightsoft° Right-J® Worksheet Entire House One Stop Cooling and Heating Job: Lot 039 F1452 B LHG - W Date: 7111/19 By: ww 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: v vwOneStopCooling.com License: CAC032444 1 Room name BED2 FOY 2 E)posed wall 37.0 ft 5.5 ft 3 Room height 8.7 ft heaV000l 8.7 ft heat/000l 4 Room dimensions 15.5 . x 11.0 ft 1.0 x 99.0 ft 5 Room area 170.5 ftz 99.0 ftz Ty Construction number U-value (Btuhfit�-°F) Or HTM (Btuh/ftz) Area (ftz) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs 4A5 lob -. _ _ , _ 0.143 0.540 n n • 3:72 _ 1,4:04 233 13.57 96 : _ _ ___0 96 __ 0. 356 _ _0 223 _.. -_o - - 6 , __ _ - 0 _ _ _0 _ . _ _:0 0 .: 0 . O :: _ . 0. IW _ 13A-4ocs 0.143 a 3.72 2.33 135 119 441 276 48 28 103 65 11 - I ::sL-p 1RJ. WI 4A5-20b 11DO 13A flocs 4A5-2o4 13A-4ocs 0.540 0.390 0.143 0.540 0.143 a a s - s ' W 14.04 10.14 3.72 -14.04. 3.72 34.61 10.72 2 33 - _ 1357 2.33 16 0 91 _._ ... 0 0 0 0 91 _Q 0 229 0 340 _0 0 566 0 213 _._. __ 0 0 0 20 0 0 0 0 20 , 0 __ 0 0 0 204 0 -0 0 0 216 0 <' _- 0 0 _ I--G I� - R C 4A5-2ob 4A5-2obd 12G OSW 1613-30ad 0.540 0.630 0.091 9.390 0.032 w w - _ n - 14.04 16.38 2 37 -_ 1014 0.83 34.61 36.89 c 115 ___ 1092 1.63 0 0 0 . .. ,._ 0 171 0 0 0 0 171. 0 0 0 0 142 0 _ 0 0 0 _ 278 0 0 87 -_16 99 0 0 71 - - --16 99 0 0 168 _ _ _102 82 0 0 81 _ : _._172 162 _30.68, .,__.000 __ 171. 37.1135 _ 6 c)AEDe.)xmw on 91 -28 Envelopelosslgain 2643 1647 888 667 12 a) Infiltration 686 . 216 102 32 b) Room ventilation 0 0 01 0 13 Internal gains: Oooupants@ 230 1 230 0 0 Applianoeslother 0 0 Subtotal (lines 6 to 13) 3329 2093 990 699 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 180 127 -990 -699 14 Subtotal 3509 2220 0 0 15 Dud loads 17% 20%0 598 444 17% 20% 0 0 FTotal room load 4107 2664 0 0 Air required (&n) 176 121 0 0 Calculations aDproved WACCA to meet all requirements of Manual J 8th Ed. -r"l- =9Y 1mtolFt sm 2019-Jul-11 09:20:30 ^�^- --!-� Right -Suite® Universal 2019 19.0.04 RSU21856 Page 7 'MCA ...Lot Specifi&ot 39u.ot 039 F1452 B LHG - W.rup Calc= MJ8 Front Doorfaces: W -�- wrightsoW Duct System Summary Entire House One Stop Cooling and Heating. 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: vmw..OneStopCooling.com License: CAC032444 For: Ryan Homes Ft. Pierce, FL Job: Lot 039 F1452 B LHG - W Date: 7111 /19 By: W W Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.16 in H2O 0.16 in H2O Available static pressure 0.34 in.H2O 0.34 in H2O Supply / return available pressure 0.170 / 0.170 in H2O 0.170 / 0.170 in H2O Lowestfriction rate 0.253 in/100ft 0.253 in/100ft Actual airflow 773 cfm 773 cfm Total effective length (TEL) 134 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BED2 h 4107 176 121 0.269 8.0 Ox0 VIFx 21.5 105.0 st2 BED3 h 1855 80 60 0.310 6.0 Ox0 VIFx 14.7 95.0 st2 BTU h 644 28 24 0.298 4.0 Ox0 VIFx 14.1 100.0 st2 DIN c 2922 110 133 0.274 7.0 Ox0 VIFx 29.1 95.0 st1 GREAT c 1653 48 75 0.299 6.0 Ox0 VIFx 18.7 95.0 st1 GREAT -A c 1653 48 75 0.306 6.0 Ox0 VIFx 16.3 95.0 st1 KIT c 1901 42 86 0.271 6.0 Ox0 VIFx 25.5 100.0 st1 MBED h 3481 149 134 0.276 7.0 Ox0 VIFx 23.3 100.0 st1 MBTH h 1431 61 30 0.271 5.0 Ox0 VIFx 25.7 100.0 st1 Mwc c 640 14 29 0.253 4.0 Ox0 VIFx 24.3 110.0 st1 PAN h 398 17 7 0.272 4.0 Ox0 VIFx 25.0 100.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 473 562 0.253 715 12.0 0 x 0 VinlFlx st2 PeakAVF 300 212 0.269 680 9.0 0 x 0 VinlFlx .� wrightisoft® 2019-Jul-1109:20:30 Right -Suite® Universal 201919.0.04 RSU21856 Page 1 / ...Lot SpecificlLot 39\Lot 039 F1452 B LHG - W.rup Calc= MJ8 Front Door faces: W Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cim) TEL R Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox0 773 773 0 0 0 0 , Ox 0 VIFx wrightsoft® 2019-Jul-1109:20:30, /9litrP�Lot Right-Suite®Universal 201919.0.04RSU21856 Paget LotSpeciridl-ot39NLot039F1452BLHG-W.rup Calc=MJ8 FrontDoorfaces: W Static Pressure and Friction Rate Job: Lot 039FUMBLHG-W wrightsoft® Date: 7/11/19 Entire House By: WW One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 = 9307 Web: wm&&0neStopCooling.com License: CAC032444 For: Ryan Homes Ft. Pierce, FL Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 Total Supply Return (ft) (ft) Measured length of run -out 12 0 Measured length of trunk 12 0 Equivalent length of fittings 110 0 Total length 134 0 Total effective length 134 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.253 > 0.18 0.253 > 0.18 Return Ducts 0.253 > 0.18 0.253 > 0.18 Fitting Equivalent LengthDetails supply 4X=35,11A=20,.11G=5,11G=5, 11G=5, 1A=35, 11G=5: TotalEL=110 Return TotalEL=0 AL wrigif"oft® 2019-Jul-1109.20.36 �+�- AMlek�/B .tr in elluaeymm uy Right-Suite®Universal 201919.0.04 RSU21856 Page 1 i9� rtiP� ...Lot SpecificlLat 391ot 039 F1452 B LHG - W.rup Calc= MJ8 Front DoorMces: W wrightsoft® Manual S Compliance Report Job: Lot 039 F1452 B LHG - WDate: 7111119 Entire House By: VW One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.com License: CAC032444 eL'roject intormation For: Ryan Homes Ft. Pierce, FL Cooling Equipment Design Conditions Outdoor design DB: 90.0°F Sensible gain: 17027 Btuh Entering coil DB: 74.0'F Outdoor design WB: 78.0°F Latent gain: 3632 Btuh Entering coil WB: 61.7°F Indoor design DB: 74:0°F Total gain: 20659 Btuh Indoor RH: 50% Estimated airflow: 773 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Goodman Mfg. Model: GSZ140241K+ARUF25B14A Actual airflow: 773 cfm Sensible capacity: 17400 Btuh 102% of load Latent capacity: 5800 Btuh 160% of load Total capacity: 23200 Btuh 112% of load SHR: 75% Design Conditions Outdoor design DB: 42.0'F Heat loss: 1.8032 Btuh Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Goodman Mfg. Model: GSZ140241K+ARUF25B14A Actual airflow: 773 cfm Output capacity: 23200. Btuh 129% of load Supplemental heat required: 0 Btuh Backup e quipment type: Elecstrip Manufacturer. Model: Actual airflow: 773 cfm Output capacity: . 8.8 kW 166% of load Temp. rise: 50 OF Meets all requirements ofACCA Manual S. Entering coil DB: 68.0°F Capacity balance:. 36 OF Economic balance: -99 OF - wrightsoft® 2019-Jul-11 09:20:30 1- a ,..•e.�.,..�.w..r�wro Right-Suite®Universal 201919.0.04RSU21856 Pagel ACCA...Lot SpecificlLot39tLot039F1452BLHG-W.rup Calc=MJ8 Front Doorfaces:W Level 1 1 = 50 CFM Fan = 80 CFM Fan 3 = 110 CFM. Fan .1 = 50 CFM Fan .2 = 80 CFM. Fan 3 = 110 CFM Fan 8X4 17 cfm R = Vent to Roof N = Vent to Wall )V = Dryer Vent