Loading...
HomeMy WebLinkAbout70 El Mar Drive Energy calsEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 49/25/2020 10:39 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY TARA DEVELOPMENT OF PALM BEACH Street: City, State, Zip:ST LUCIE COUNTY , FL , 70 N ELMAR DRIVE Permit Number: Design Location:FL, Fort Pierce County:St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Multi-family 1 No 1298 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.96 126.00 ft² SHGC=0.38 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1298.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1360.00 ft² b. N/A R=f t ² c. N/A R=f t ² 10. Ceiling Types a. Under Attic (Vented)R=30.0 1298.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Main, AH: Main 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 40 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:2.000 ft. Area Weighted Average SHGC:0.380 Description Area Insulation Area Insulation Area Insulation Area 15. Credits Pstat 2 (126.0 sqft.) (1360.0 sqft.) (1298.0 sqft.) (1298.0 sqft.) Conditioned floor area below grade (ft²)0 a. Central Unit a. Electric Heat Pump k B t u / h r 28.6 SEER:14.00 Efficiency k B t u / h r Efficiency 30.0 HSPF:8.20 f t ² R 6 259.6 EF: 0.920 Glass/Floor Area:0.097 Total Proposed Modified Loads: Total Baseline Loads: 43.64 46.53 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY 1 TARA DEVELOPMENT OF P Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 1298 2 New (From Plans) Multi-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , ST LUCIE COUNTY , St. Lucie 70 N ELMAR DRIVE Street Address Comment: Building Type:User Cross Ventilation: Whole House Fan: TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinterSummer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Block1 1298 10384 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 Main 1298 10384 Yes 4 2 Yes Yes1Yes #Floor Type Area Tile Wood Carpet FLOORS R-ValueSpacePerimeter 1 1298 ft² 0 0 1______Slab-On-Grade Edge Insulation - - - -0152 ft Main #Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Composition shingles 1406 ft² Medium 0.96 0 22.6______No0 ft² 0.9 NoN ATTIC #Type Ventilation Area RBS IRCCVent Ratio (1 in) ______1 Full attic Vented 1298 ft² N N150 #Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 1298 ft² 0.11 Wood______Main Blown 9/25/2020 10:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.09999 0Main358NConcrete Block - Int Insul 0.150Exterior280.0 ft² ____ 2 4.09999 0Main508EConcrete Block - Int Insul 0.150Exterior400.0 ft² ____ 3 4.09999 0Main358SConcrete Block - Int Insul 0.150Exterior280.0 ft² ____ 4 4.09999 0Main508WConcrete Block - Int Insul 0.150Exterior400.0 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .46 20 ft² None______W Main 863 #Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 N Single (Tinted)0.96 0.38 15.0 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes1 N 2 N Single (Tinted)0.96 0.38 15.0 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes1 N 3 S Single (Tinted)0.96 0.38 45.0 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes3 N 4 S Single (Tinted)0.96 0.38 22.5 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes3 N 5 W Single (Tinted)0.96 0.38 22.5 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes4 N 6 W Single (Tinted)0.96 0.38 6.0 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes4 N Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1211.5 766.51.000356Wholehouse .1233125.08Proposed ACH(50)1 HEATING SYSTEM #System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Heat Pump/HSPF:8.2 30 kBtu/hr ______sys#1None1 Single #System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 14 28.6 kBtu/hr 858 cfm 0.75______sys#1None1 Single #System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.92 40 gal 50 gal 120 deg None______None Main 9/25/2020 10:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ #Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 259.6 ft²Main 64.9 ft² Default Leakage Main (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD)AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH)AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 MECHANICAL VENTILATION Supply CFM Exhaust CFM Heating System Cooling SystemHRVTypeRun TimeFan Watts 0 0 0None 1 - Electric Heat Pump 1 - Central Unit0% MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 Main 9/25/2020 10:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT