HomeMy WebLinkAbout70 El Mar Drive Energy calsEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 49/25/2020 10:39 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction:
ST LUCIE COUNTY
TARA DEVELOPMENT OF PALM BEACH
Street:
City, State, Zip:ST LUCIE COUNTY , FL ,
70 N ELMAR DRIVE
Permit Number:
Design Location:FL, Fort Pierce County:St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Multi-family
1
No
1298
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.96 126.00 ft²
SHGC=0.38
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1298.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1360.00 ft²
b. N/A R=f t ²
c. N/A R=f t ²
10. Ceiling Types
a. Under Attic (Vented)R=30.0 1298.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Main, AH: Main
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 40 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:2.000 ft.
Area Weighted Average SHGC:0.380
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits Pstat
2
(126.0 sqft.)
(1360.0 sqft.)
(1298.0 sqft.)
(1298.0 sqft.)
Conditioned floor area below grade (ft²)0
a. Central Unit
a. Electric Heat Pump
k B t u / h r
28.6 SEER:14.00
Efficiency
k B t u / h r Efficiency
30.0 HSPF:8.20
f t ² R
6 259.6
EF: 0.920
Glass/Floor Area:0.097 Total Proposed Modified Loads:
Total Baseline Loads:
43.64
46.53 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
ST LUCIE COUNTY
1
TARA DEVELOPMENT OF P
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
1298
2
New (From Plans)
Multi-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
ST LUCIE COUNTY ,
St. Lucie
70 N ELMAR DRIVE
Street Address
Comment:
Building Type:User
Cross Ventilation:
Whole House Fan:
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinterSummer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Block1 1298 10384
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 Main 1298 10384 Yes 4 2 Yes Yes1Yes
#Floor Type Area Tile Wood Carpet
FLOORS
R-ValueSpacePerimeter
1 1298 ft² 0 0 1______Slab-On-Grade Edge Insulation - - - -0152 ft Main
#Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Composition shingles 1406 ft² Medium 0.96 0 22.6______No0 ft² 0.9 NoN
ATTIC
#Type Ventilation Area RBS IRCCVent Ratio (1 in)
______1 Full attic Vented 1298 ft² N N150
#Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented)30 1298 ft² 0.11 Wood______Main Blown
9/25/2020 10:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.09999 0Main358NConcrete Block - Int Insul 0.150Exterior280.0 ft² ____
2 4.09999 0Main508EConcrete Block - Int Insul 0.150Exterior400.0 ft² ____
3 4.09999 0Main358SConcrete Block - Int Insul 0.150Exterior280.0 ft² ____
4 4.09999 0Main508WConcrete Block - Int Insul 0.150Exterior400.0 ft² ____
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Insulated .46 20 ft² None______W Main 863
#Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 N Single (Tinted)0.96 0.38 15.0 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes1 N
2 N Single (Tinted)0.96 0.38 15.0 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes1 N
3 S Single (Tinted)0.96 0.38 45.0 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes3 N
4 S Single (Tinted)0.96 0.38 22.5 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes3 N
5 W Single (Tinted)0.96 0.38 22.5 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes4 N
6 W Single (Tinted)0.96 0.38 6.0 ft² 2 ft 0 in 1 ft 0 in NoneMetal None______Yes4 N
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1211.5 766.51.000356Wholehouse .1233125.08Proposed ACH(50)1
HEATING SYSTEM
#System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Heat Pump/HSPF:8.2 30 kBtu/hr ______sys#1None1 Single
#System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 14 28.6 kBtu/hr 858 cfm 0.75______sys#1None1 Single
#System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.92 40 gal 50 gal 120 deg None______None Main
9/25/2020 10:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
#Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 259.6 ft²Main 64.9 ft² Default Leakage Main (Default) c______1 1 (Default) c
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
Heating (WEH)AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
MECHANICAL VENTILATION
Supply CFM Exhaust CFM Heating System Cooling SystemHRVTypeRun TimeFan Watts
0 0 0None 1 - Electric Heat Pump 1 - Central Unit0%
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 Main
9/25/2020 10:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4