Loading...
HomeMy WebLinkAboutRevision; Product Approval Chart, Change to PGT WindowsOFFICE USE ONLY: DATE FILED: REVISION FEE:' 7 .�— PERMIT # 1903-0461 RECEIPT # RECEIVED PLANNING & DEVELOPMENT SERVICE BUILDING & CODE REGULATION DIVISIO APR 2 2 2019 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 ST. Lucie County, Permitting (772) 462-1553 FAX (772) 462-1578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/BYTE 5227 Oakland Lake Cir. lot 49 ADDRESS: 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: 3. 4. Revision to Product Approval Chart. Changed to PGT Windows. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC057817 Y WHO" CERT. #: BUSINESS NAME: QUALIFIERS NA ADDRESS: 450 CENTR PARK , CITY: STATE: ZIP: PHONE (DAYTIME): FAX: 561-720-1341 OWNER/BUILDER INFORMATION: NAME: NVR, INC. dba RYAN HOMES ADDRESS: CITY: PHONE: 561-818-7950 STATE: FAX: ZIP: 5. ARCHITECT/ENGINEER INFORMATION: NAME: AB DESIGN GROUP INC. ADDRESS: CITY: LONGWOOD STATE: FL ZIP: 32750 PHONE (DAYTIME): 407-774-6078 FAX: _ _ Revised 07/22/2014 FILE C - 4., 1- 1 0 ! ii] JN a Planning & Development Services Department Building & Regulations Division Product Review Affidavit Building Permit # / / 03 — OL'fW Owners Name: NVR Inc DBA Ryan Homes rn . n E itJ c a LIJ �l o ,JUJ U L1C CL- a) Q U 7 J Applicant: NVR Inc DBA Ryan Homes Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model # Product Approval Number Glass Type Method of Attachment Windows +32.37/-42.62 +50.2/-50.2 PGT Industries SH-200 17-0630.02 non -impact # 10 Wood Screw with sufficient length to achieve 1-1/4" embedment. Required anchors: Head (3), Jamb (3) Mullions N/A +/-75 PGT Industries PGT 17-0630.01 N/A Use Y." Tapcon with sufficient length to achieve a 1'/<" min. embedment with 2 %," minimum edge distance Fixed Glass +29.65/-38.87 +/-58.9 PGT Industries PW-220 17-0614.05 non -impact # 1D Wood Screw with sufficient length to achieve 1-1/4" embedment. Required anchors: Head (3), Jamb (3) Sliding Glass Doors +28.74/-42.62 +35.3/-89.6 PGT Industries SGD-2500 18-0207.05 non -impact 3/16" Tapcon with sufficient length to achieve 1-1/4" embedment. Required anchors: Head/Sill (6), Jamb (5) Swing Type Doors +30.64/-30.64 +67.0/-67.0 Therma Tru 310"x8'0" FL 5891.5 N/A ITW Tapcon X", Min Embedment 1-1/4", Min Clearance to edge 2", Min Clearance to adjacent anchor 4"; OR ELCO Tapcon 1/4", Min Embedment 1-1/4", Min Clearance to edge 1", Min Clearance to adjacent anchor 4". Anchor Spacing Max 18.5" O.0 Garage Doors +25.91/-31.39 +36/-42 Clopay 160 model 73W6 FL 16546.4 N/A Jamb to block on vertical jamb 1/4" X 11/4" min embedded Tapcon. Max spacing of 71/2" and 1" OD steel washer required. Hurricane Protection N/A +40/-40 Eastern Metal 24ga Steel Panels FL 11964.2 N/A 1/4" Tapcon Anchors, SG Tapcons or 1/4" X 3/4". All points Solid -set Anchors. Roofing Material N/A N/A Tamko N/A FL18355.1 N/A Soffits (Panel Walls) N/A N/A Ply Gem Mastic Soffits FL 23352.1 N/A Structural Component N/A N/A Huber Eng. ZIP System FL 17147.2 N/A [.have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: James Joseph Cantwell Signature: _JAMES JOSEPH CANTWELL 11VTLTjy Design Prof: Architect Cert. No. AR0012079 Date: _ 4/16/2019