Loading...
HomeMy WebLinkAbout2756 Brocksmith Rd_SAMPSON-MANUAL Jd Pro S Job: +� wrightsoft Project Summary Date: Entire House By. QUICK CALCS, INC. 317 ST LUCIE LANE,FT PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM Project • • For: RICH SAMPSON 2756 BROCKSMITH RD.,FT.PIERCE,FL 34945 Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21425 Btuh Structure 19855 Btuh Ducts 6409 Btuh Ducts 9339 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27834 Btuh Use manufacturer's data In Rate/swin multiplier 0.95 Infiltration Equipmen�sensible load 27734 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3586 Btuh Ducts 2537 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(ft�) 1745 1745 Equipment latent load 6124 Btuh Volume(ft3) 15701 15701 Air changes/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 33858 Btuh Equiv.AVF(cfm) 99 52 Req.total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade LENNOX Trade LENNOX Model 14HPX-042-230-22 Cond 14HPX-042-230-22 AHRI ref 201851180 Coil CBA38MV-042-230*++TDR AHRI ref 201851180 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 29750 Btuh Heating output 42000 Btuh @ 47°F Latent cooling 12750 Btuh Temperature rise 27 °F Total cooling 42500 Btuh Actual airflow 1417 dim Actual airflow 1417 cfiT1 Air flow factor 0.051 cfm/Btuh Air flow factor 0.049 cfim/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point=31 °F Backup: Input=8 kW, Output=27194 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2020-0ct-01 09:16:32 �� M^ Right-Sute®Universal 2019 19.0.07 RSU08101 Page 1 ACCA ...ICK\Docunents\Wrightsoft HVAC\SAMPSON,RICH.rup Calc=MJ8 Front Door faces:W Duct stem Summary Job: +� wrightsoft D S S y Date: Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE,FT.PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM Project Information For: RICH SAMPSON 2756 BROCKSMITH RD.,FT.PIERCE,FL 34945 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.344/0.156 in H2O 0.344/0.156 in H2O Lowest friction rate 0.197 in/100ft 0.197 in/100ft Actual airflow 1417 cfm 1417 cfm Total effective length(TEL) 254 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(ft) Trunk ;IVING ROOM c 2037 58 99 0.258 7.0 Ox 0 VIFx 18.5 115.0 st2 ;IVING ROOM-A c 2037 58 99 0.253 7.0 Ox 0 VIFx 20.7 115.0 st2 BATH 2 h 956 49 33 0.203 4.0 Ox 0 VI Fx 34.2 135.0 st2 BEDROOM2 h 4021 205 177 0.209 7.0 Ox0 VIFx 29.6 135.0 st2 CLST. h 1306 67 23 0.197 4.0 Ox 0 VIFx 39.9 135.0 st2 DEN c 3451 119 167 0.198 7.0 Ox 0 VIFx 39.0 135.0 st2 DINING c 3350 103 163 0.243 6.0 0x 0 VI Fx 26.4 115.0 st2 FOYER h 786 40 26 0.241 6.0 Ox 0 VI Fx 27.6 115.0 st2 KITCHEN c 3164 27 154 0.341 8.0 0x 0 VI Fx 5.8 95.0 M BATH h 3220 164 65 0.238 6.0 0x 0 VI Fx 29.5 115.0 st1 MASTER BATH-A c 4614 212 224 0.315 9.0 Ox 0 VI Fx 14.2 95.0 NOOK h 3957 201 137 0.347 7.0 0x 0 VI Fx 4.1 95.0 PANTRY h 883 45 20 0.320 4.0 Ox0 VIFx 12.4 95.0 WIC h 1386 71 30 0.232 4.0 0x 0 VIFx 33.3 115.0 st1 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 PeakAVF 698 787 0.197 737 14.0 0 x 0 VinlFlx st1 PeakAVF 234 95 0.232 877 7.0 0 x 0 VinlFlx Bolditalic values have been manually overridden wrightsoft® 2020-Oct-01 09:16:32 AM,.ek,Iae„n„e-h-,C-p-, Right-Sute®UNVersal201919.0.07 RSU08101 Page l +CA ...ICK\Documents\wrightsoft HVAC\SAMPSON,RICH.rup Calc=MJ8 Front Door faces:W TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb3 Ox 0 446 319 79.4 0.197 568 12.0 0x 0 VI Fx rb6 Ox0 161 261 74.4 0.210 187 16.0 Ox 0 VIFx rb4 Ox0 98 125 0 0 0 0 Ox 0 VIFx rb2 Ox 0 273 310 0 0 0 0 Ox 0 VI Fx rb7 Ox 0 253 210 0 0 0 0 Ox 0 Wx rb5 Ox 0 185 191 0 0 0 0 Ox 0 Wx Bolditalic values have been manually overridden wrightsoft® 2020-Oct-01 09:16:32 A II,-=Iae,•.-.—aw=.C—,,. Right-Sute®Uriversal 2019 19.0.07 RSU08101 Page 2 ACCP. ...ICK\Documents\Wrightsoft HVAC\SAMPSON,RICH.rup Calc=MJ8 Front Door faces:W N TLT 164 dm 6" M BATH TER BATH - $46 cfm 224 dm 4X14 WIC 9 NOOK 71 cfm 201 cfm 99 dm 1 X10X9 7" © BEDROOM i' 10" 1a� 7k�� A OOM 154 dm 205 dm KITCHEN \dm 4' 99 ch 7' Z 310 cfm GARAGE 49 s I 163 cfm 67 dn 45 dr,1)(24 10X10X9 167 dm 40 cfm CL5T. PANTRY DINING FOYER DEN Job#: QUICK CALCS, INC. Scale: 1 : 115 Performed for: Page 1 RICH SAMPSON 317 ST LUCIE LANE RightSuite®Universal2019 2756 BROCKSMITH RD. FT.PIERCE, FL 34946 19.0.07 RSU08101 FT.PIERCE, FL 34945 Phone:772-466-6799 2020-0ct-01 09:1418 QUICKCALCS@AOL COM rightsoft HVACZAMPSON,RICH.nap