Loading...
HomeMy WebLinkAboutAPPROVED Current - FL20378_R1_II_FL 20378.6_5V Crimp Product Report Manufacturer: Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, FL 34990 ( 772) 872-8034 Compliant with Florida Building Code 2017 (61h ed.) Compliant with Florida Product Approval Rule #61G20-3 Compliant : Keystone Certifications Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec. 1507.4.3 Yield strength:40ksi Steel Attached to min. 15/32" plywood or Wood Deck w/ min. Attached 24" 0.42 specific gravity with screws. 24" Coverage Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1506, 1507 Fastener for Method 1 Attachment # 9-15 x 1"Hex Head w/EPDM Bonded Steel Washer to penetrate 3/16" thru wood decking Fastener for Method 2 Attachment # 9-15 x 1" Hex Head w/EPDM Bonded Steel Washer to penetrate 3/16"thru 15/32"min. plywood deck or 5/8" into wood plank Underlayment: To be compliant with FBC Sec.1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 FASTENER PLACEMENT DESIGN PRESSURE* -85 PSF -114.25 PSF METHOD 11N R19 PEAKS ROW SPACING 12"O.C. 12"O.C. METHOD 2IN PANEL FLATS FASTENER SPACING 12" O.C. 12"O.C. *SEE INSTALL DRAWINGS FASTENER SIZE: #9 #9 *ALLOWABLE DESIGN PRESSURE MARGIN OF 2 TO 1 Reference Data: HURRICANE TEST LAB #TST ID: 1527 TAS 12S-03 Test# 0223-0307-01;METHOD 1 (UL 1897-041) TAS-125-03 Test # 0223-0517-06,METHOD 2 EQUIVALENCY UL 1897-04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD * DESIGN PRESSURE SAFETY MARIGIN 2;1 Certificate of Independence: Locke Bowden,P.E.does not have,not will acquire a financial interest in any company manufacturing or distributing products under this evaluation. , ,t++a+�+I ,r Locke Bowden,P.E. is not owned,operated,or controlled by any company,manufacturer,or distributlrjg�o 44t4ridef tf%-' report. �.C); ��' °• ': �''i Rits rti ' o�rAk. Compliance Statement: These products herein evaluated have demonstrated compliance with the Florida Building Code 2017 6ch ed.,with referenced documents submitted. Limitations: 1. Underlayment to be compliance with current Florida Building Code 2017 6th ed,Section 1507.1.1 2. Products are compliant for State of Florida product approval per Rule 61G20-3 3. Compliance Method: 1-D 4. Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 5. All support framing compliant w/Florida Building Code 2017, Chapters 22 for Steel,23 for Wood and 16 for Structural Loading. Design of support and attachment to the framing is outside the scope of this evaluation. 6. Rule 61G20-3 allows for engineering analysis by registered/licensed others for"project specific approval" by local authorities,authorized by the code,and is the responsibility of others. 7. This report does not imply warranty, installation, recommended product use outside of this report. _Fasteners- 09-15 Hex-Heed Screws With 5V-CrirrV" Root Panel EPDA9 Bonded Steel Washers ' ' I � 1 I f' Deck. -15132"or greater Plywood.or -Wood plank Fasteners- 09-15 Hex-Head Screws With 5V-Crlmp" Roof Panel EPDM Banded Steel Washers ' - - I Cf �� a a r -- —.�_�.T---T---Tom•—____���____���.v�__-__� - Deck: -15132"or greater Plywood.or -Wood plank