HomeMy WebLinkAboutAPPROVED FL10497_R6_II_2017_09_FINAL_A1_ER_MULE-HIDE_FL10497-R6 copy 2 Q0TRINITY 'ERD APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 4 16-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4 113-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5 1C Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6 1D Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 7 1E-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 8 1E-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 9 1F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 9 2A Steel or Conc. New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 10 2B Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 11 3A Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 12-14 3B Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 14 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 15-16 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 16 4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 17-18 5A CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 19 5B CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 19 5C CWF New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 19 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 20 6B Gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 21 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 21-22 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: ➢Wood: Minimum 0.75-inch penetration. ➢Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocya nu rate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the CIA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 1 of 22 QO TRINITY ERD 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt: Full coverage at 25-30 Ibs/square. ➢ Dow Insta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. ➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢ OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic(OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesives CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. ➢ Note: When multiple loyers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick) ➢ OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) ➢ OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL) ➢ OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II,Poly ISO 2) ➢ ICP Adhesives CR-20: MDP -117.5 psf (Min.1.0-inch thick) 8. Bonded polyisocya nu rate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced,refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 2 of 22 QO TRINITY ERD 15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. TABLE 1:MULE-HIDE ROOF COVERS Reference Layer Material Application Base Ply One or more plies SA Base Sheet,SA Base Sheet(FR) SBS-SA Cap SA-SBS Cap Sheet,SA-SBS Cap Sheet(FR) Self-Adhering (SBS,Self-Adhering) Note: Self-adhering membranes shall not be installed over APP-TA membranes. APP-TA Base Ply or Ply One or more plies APP Torch Base,APP Torch S Torch Applied (APP,Torch-Applied) Cap APP Torch S,APP Torch G,APP Torch G FR,APP Torch KoolCap G,APP Torch KoolCap G FI R APP-SA Cap SA-APP Cap Sheet,SA-APP Cap Sheet(FR),SA-APP KoolCap G,SA-APP KoolCap G(FR) Self-Adhering (APP,Self-Adhering) Note: Self-adhering membranes shall not be installed over APP-TA membranes. 16. Any FBC Approved coating listed for use with SBS or APP modified bitumen roofing may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. 17. Dens Deck shall be field-primed with PG100 prior to self-adhering membrane application. Refer to tables herein for other priming requirements. 18. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those in Table 3A applies: VAPOR BARRIER OPTIONS;STRUCTURAL CONCRETE DECK;ADHERED INSULATION PER TABLE 3A Option# Primer Type Vapor Barrier Attach Insulation Adhesive MDP(psf) VB-1. Mule-Hide 121 SA Base Sheet Self-Adhering Inta-Stik or CR-20,12-inch o.c. -60.0 VB-2. Mule-Hide 121 APP Torch Base Torch-applied Inta-Stik or CR-20,12-inch o.c. -75.0 VB-3. Mule-Hide 121 SA-SBS Cap Sheet Self-Adhering Insta-Stik,12-inch o.c. -75.0 VB-4. Mule-Hide 121 SA-SBS Cap Sheet Self-Adhering Millennium One Step Foamable Adhesive,12-inch o.c. -157.5 VB-5. Mule-Hide 121 SA-SBS Cap Sheet Self-Adhering CR-20,12-inch o.c. -270.0 VB-6. Mule-Hide 121 SA Base Sheet,SA Base Sheet(FR) Self-Adhering Millennium One Step Foamable Adhesive,Millennium PG-1 Pump Grade -290.0 Adhesive,OlyBond 500 or CR-20,12-inch o.c. 19. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 3 of 22 QOTRINI-FY 'ERD TABLE 1A: WOOD DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Nate 15) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap (psf) Min.15/32- Min.1.5-inch ACFoam II,ACFoam III,ENRGY-3,H- D-IS,M-OSFA, (Optional)additional D-IS,M-OSFA, SBS-SA,APP-SA, W 1 inch plywood Shield,H-Shield CG,Multi-Max FA3 OB500 or CR-20 layers(s)of base insulation OB500 or CR-20 SBS-SA (Optional)SBS-SA,APP-TA APP TA 52.5 TABLE 113-1: WOOD DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) 117MSYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Type Attach BPly Ply Cap (PSfl TORCH-APPLIED BASE PLY: Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional)Min.1.5- inch ACFoam II, Min.0.25-inch Dens Min.19/32- CertainTeed Glasbase, inch diameter tin lap and 8-inch o.c. Poly ISO 2,ENRGY- Deck,Dens Deck Prime, Hot (Optional) W-2 inch Firestone MB Base,JM caps with 11 ga. in three(3),equally Hot asphalt APP-TA APP-TA -60.0 plywood Perma-Ply 28,Tamko annular ring spaced,staggered 31 H-Shield,Poly SECUROCK Gypsum- asphalt APP-TA Glass Base,GAFGLAS#75 shank nails center rows ISO 2,H-Shield CG, Fiber Roof Board Multi-Max FA3 9-inch o.c.in 4-inch (Optional)Min.1.5- Min.15/32- lap and 9-inch o.c. inch ACFoam ll, Min.0.25-inch Dens Simplex MAXX Poly ISO 2,ENRGY- Deck Prime,SECUROCK Hot (Optional) W-3 inch Polyglass G2 Base Cap in four(4),equally 31 H-Shield,Poly Hot asphalt Gypsum-Fiber Roof asphalt APP-TA APP-TA APP-TA 82.5 plywood spaced,staggered ISO 2,H-Shield CG, Board center rows Multi-Max FA3 32 ga.,1-5/8- 6-inch o.c.in 4-inch (Optional)Min.1.5- Min.15/32- inch diameter tin lap and 6-inch o.c. inch ACFoam ll, Min.0.25-inch Dens W-4 inch Polyglass G2 Base caps with 12 ga. in five(5)equally Poly ISO 2,ENRGY- Hot asphalt Deck Prime,SECUROCK Hot APP-TA (Optional) APP-TA -90.0 plywood annular ring spaced,staggered 3,H-Shield,Poly Gypsum-Fiber Roof asphalt APP-TA shank nails center rows ISO 2,H-Shield CG, Board Multi-Max FA3 SELF-ADHERING BASE PLY: Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional)Min.1.5- Min.19/32- CertainTeed Glasbase, inch diameter tin lap and 8-inch o.c. inch ACFoam II, Min.0.25-inch Dens (Optional) SBS-SA, ENRGY- , W-5 inch Firestone MB Base,JM caps with 11 ga. in three(3),equally Poly ISO 2, Hot asphalt Deck Dens Deck Prime, Hot SBS-SA SBS-SA,APP- APP-SA, -60.0 plywood Perma-Ply 28,Tamko annular ring spaced,staggered 3,H-Shield,Poly SECUROCK Gypsum- asphalt TA APP-TA Glass Base,GAFGLAS#75 shank nails center rows ISO 2,H-Shield CG, Fiber Roof Board Multi-Max FA3 32 ga.,1-5/8- 6-inch D.C.in 4-inch Min.2-inch D-IS,OB500, Min.19/32- inch diameter tin lap and 6-inch o.c. ACFoam II,Poly ISO CR-20,M- D-IS, (Optional) SBS-SA, H- OSFA ACFoam III, ,atop (Optional)Additional OB500, W-6 inch Nail Base caps with 12 ga. in four(4),equally 2, SBS-SA SBS-SA,APP- APP-SA, -60.0* plywood annular ring spaced,staggered Shield,Poly ISO 1, fastener layers of base insulation CR-20, TA APP-TA shank nails center rows H-Shield CG,Multi- rows,7-inch M-OSFA Max FA3,ENRGY-3 D.C. Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 4 of 22 QOTRINI-FY 'ERD TABLE 113-2: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Type Attach BPly Ply Cap (psf) TORCH-APPLIED BASE PLY: 12-inch o.c.in 4-inch (Optional)Min.1.5-inch lap and 12-inch DC ACFoam II Poly ISO 2 Min. inch Dens Min.19/32- OMG Flat Bottom Plates . . , , Den Hot Deck,Dens Deck Prime, Hot (Optional) W 7 inch plywood Nail Base (square)with Roofgrip#12 in two(2),equally ENRGY-3,H-Shield,Poly asphalt SECUROCK Gypsum- asphalt APP-TA APP TA APP-TA -60.0 spaced,staggered ISO 2,H-Shield CG,Multi- center rows Max FA3 Fiber Roof Board Dekfast Hex Plates with Dekfast#14,OMG 3" 9-inch o.c.in 4-inch (Optional)Min.1.5-inch Round Metal Plate with Min.0.25-inch Dens lap and 9-inch o.c.in ACFoam II,Poly ISO 2, Min.15/32- Polyglass OMG HD,OMG Flat Hot Deck,Dens Deck Prime, Hot (Optional) W-8 four(4),equally ENRGY-3,H-Shield,Poly APP-TA APP-TA -82.5 inch plywood G2 Base Bottom Plate(Accutrac) asphalt SECUROCK Gypsum- asphalt APP-TA Maxcenter rows Mwith Roofgrip#14 or spaced,staggered a FA3 1,H-Shield CG,Multi- Fiber Roof Board Trufast 3"Metal Insulation Plate with Trufast HD. SELF-ADHERING BASE PLY: 12-inch o.c.in 4-inch (Optional)Min.1.5-inch Min.0.25-inch Dens Min.19/32- OMG Flat Bottom Plates Hot Deck,Dens Deck Prime, Hot lap and 12-inch D.C. ACFoam ll,Poly ISO 2, (Optional) SBS-SA, W-9 Nail Base in two,equally ENRGY-3,H-Shield,Poly Fiber Roof SBS-SA SBS-SA,APP- APP-SA, -60.0 inch plywood (square)with Roofgrip#12 spaced,staggered ISO 2,H-Shield CG,Multi- asphalt SE Fiber Roof Board Gypsum- asphalt TA APP-TA center rows Max FA3 Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 5 of 22 QOTRINI-FY 'ERD TABLE 1C: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Top Insulation Layer777 Roof Cover(Note 15) No. Deck(Note 1) Base Insulation Layer Type Fasten Attach Base Ply Ply Cap MDP(psf) TORCH-APPLIED BASE PLY: Dekfast Hex Plates with Dekfast#14, Min.15/32- (Optional)One or more Min.0.25-inch Dens Deck OMG 3"Round Metal Plate with OMG 1 per 2 W-10 layers,any combination, Prime or SECUROCK HD,OMG Flat Bottom Plate(Accutrac) z APP-TA (Optional)APP-TA APP-TA -30.0 inch plywood loose laid Gypsum-Fiber Roof Board with Roofgrip#14 or Trufast 3"Metal ft Insulation Plate with Trufast HD. SELF-ADHERING BASE PLY: Dekfast Hex Plates with Dekfast#14, (Optional)One or more Min.0.25-inch Dens Deck OMG 3"Round Metal Plate with OMG Min.15/32- 1 per 2 SBS-SA,APP-SA, W-11 layers,any combination, Prime or SECUROCK HD,OMG Flat Bottom Plate(Accutrac) Z SBS-SA (Optional)SBS-SA,APP-TA -30.0 inch plywood loose laid Gypsum-Fiber Roof Board with Roofgrip#14 or Trufast 3"Metal ft APP-TA Insulation Plate with Trufast HD. (Optional)One or more Dekfast Galvalume Steel Hex with Dekfast Min.19/32- Min.1.5-inch ENRGY 3,H- 1 per SBS-SA,APP-SA, W-12 layers,any combination, #12 DP or Mule-Hide 3"Insulation Plate Z SBS-SA (Optional)SBS-SA,APP-TA -82.5 inch plywood loose laid Shield,Poly ISO 1,Polytherm with Mule-Hide Drill Point Fastener 1.33 ft APP-TA Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 6 of 22 QO TRINITY ERD I TABLE 1D: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPED:PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck(Note 1) aye Insulation Lrs) 77_ Base Sheet Roof Cover(Note 15) No. Type Attach Base Fasten Attach Base Ply Cap MDP(psf) TORCH-APPLIED BASE PLY: Nail Base,Polyglass G2 Base, OMG Flat Bottom Plates(square) One or more 12-inch o.c.in 4-inch lap and 12- Min.19/32- Prelim. CertainTeed Glasbase,Firestone MB with Roofgrip#14,Dekfast Hex with W-13 inch plywood layers any Attached Base,JM Perma-Ply 28,Tamko Glass Dekfast#14 or Trufast 3"Metal inch o.c.in two(2),equally (Optional)APP-TA APP-TA 52.5 combination spaced,staggered center rows Base or GAFGLAS#75 Insulation Plate with Trufast HD One or more 12-inch o.c.in 4-inch lap and 12- Min.19/32- Prelim. OMG Flat Bottom Plates(square) W 14 inch plywood layers,any Attached Nail Base with Roofgrip#12 inch D.C.in two(2),equally (Optional)APP-TA APP-TA -60.0 combination spaced,staggered center rows Dekfast Hex Plates with Dekfast #14,OMG 3"Round Metal Plate One or more 10-inch o.c.in 4-inch lap and 10- W-15 Min.15/32- layers,any Prelim. Polyglass G2 Base,Nail Base with OMG HD,OMG Flat Bottom inch o.c.in three(3),equally (Optional)APP-TA APP-TA -75.0 inch plywood combination Attached Plate(Accutrac)with Roofgrip#14 spaced,staggered center rows or Trufast 3"Metal Insulation Plate with Trufast HD. Dekfast Hex Plates with Dekfast #14,OMG 3"Round Metal Plate One or more 9-inch o.c.in 4-inch lap and 9- W-16 Min.15/32- layers,any Prelim. Polyglass G2 Base,Nail Base with OMG HD,OMG Flat Bottom inch o.c.in four(4),equally (Optional)APP-TA APP-TA -90.0 inch plywood combination Attached Plate(Accutrac)with Roofgrip#14 spaced,staggered center rows or Trufast 3"Metal Insulation Plate with Trufast HD. SELF-ADHERING BASE PLY: Min.19/32- One or more Prelim. Dekfast Hex with Dekfast#14 or 12-inch o.c.in 4-inch lap and 12- SBS-SA, W-17 layers,any Nail Base Mule-Hide 3"Insulation Plate with inch o.c.in two(2),equally SBS-SA APP-SA, -52.5* inch plywood combination Attached Mule-Hide HDP Fastener spaced,staggered center rows APP-TA Min.19/32- One or more Prelim. OMG Flat Bottom Plates(square) 12-inch o.c.in 4-inch lap and 12- SBS-SA, Attached W-18 layers,any Nail Base inch o.c.in two(2),equally SBS-SA APP-SA, -60.0* inch plywood combination with Roofgrip#12 spaced,staggered center rows APP-TA Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 7 of 22 QOTRINI-FY 'ERD TABLE 1E-1: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER System Deck(Note 1) Base Sheet Roof Cover(Note 15) No. Base Fasten Attach Base Ply Cap MOP(psf) TORCH-APPLIED BASE PLY: W 19 Min.15/32- Nail Base Simplex MAXX Cap 9-inch o.c.at 2-inch lap and 18-inch o.c.in two(2), (Optional)APP-TA APP-TA -45.0* inch plywood equally spaced,staggered center rows W 20 Min.15/32- Nail Base Simplex MAXX Cap 9-inch o.c.at 2-inch lap and 12-inch o.c.in two(2), (Optional)APP-TA APP-TA -52.5 inch plywood equally spaced,staggered center rows W 21 Min.15/32- APP Torch Base,Nail Base Original Simplex Cap Nails(1-inch metal head diameter, 6-inch o.c.at 3-inch lap and 6-inch o.c.in four(4), (Optional)APP-TA APP-TA -52.5 inch plywood 11 gauge x min.1.25-inch long annular grooved shank) equally spaced,staggered center rows Nail Base,Polyglass G2 Base, W 22 Min.19/32- CertainTeed Glasbase,Firestone 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 8-inch o.c.in 4-inch lap and 8-inch o.c.in three(3), (Optional)APP-TA APP-TA -60.0 inch plywood MB Base,JM Perma-Ply 28,Tamko ring shank nails equally spaced,staggered center rows Glass Base or GAFGLAS#75 W 23 Min.15/32- Polyglass G2 Base,Nail Base 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 8-inch o.c.in 4-inch lap and 8-inch o.c.in four(4), (Optional)APP-TA APP-TA -67.5 inch plywood ring shank nails equally spaced,staggered center rows W 24 Min.15/32- Polyglass G2 Base,Nail Base Simplex MAXX Cap 10-inch o.c.in 4-inch lap and 10-inch o.c.in three (Optional)APP-TA APP-TA -75.0 inch plywood (3),equally spaced,staggered center rows W 25 Min.15/32- Polyglass G2 Base,Nail Base Simplex MAXX Cap 9-inch o.c.in 4-inch lap and 9-inch o.c.in four(4), (Optional)APP-TA APP-TA -90.0 inch plywood equally spaced,staggered center rows W 26 Min.15/32- Nail Base Simplex MAXX Cap 6-inch o.c.at 2-inch lap and 6-inch o.c.in two(2), (Optional)APP-TA APP-TA -90.0 inch plywood equally spaced,staggered center rows W 27 Min.15/32- Elastobase Simplex MAXX Cap 6-inch o.c.at 2-inch lap and 6-inch o.c.in three(3), (Optional)APP-TA APP-TA -105.0 inch plywood equally spaced,staggered center rows W 28 Min.19/32- Elastobase or Elastobase Poly 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 6-inch o.c.in 4-inch lap and 6-inch o.c.in four(4), (Optional)APP-TA APP-TA -112.5 inch plywood ring shank nails equally spaced,staggered center rows SELF-ADHERING BASE PLY: W 29 Min.15/32- Nail Base Original Simplex Cap Nails(1-inch metal head diameter, 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, (Optional)SBS-SA SBS-SA,APP- -52.5 inch plywood 11 gauge x min.1.25-inch long annular grooved shank) equally spaced,staggered center rows SA,APP-TA W-30 Min.19/32- Nail Base 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 8-inch o.c.in 4-inch lap and 8-inch o.c.in three, (Optional)SBS-SA SBS-SA,APP- -60.0 inch plywood ring shank nails equally spaced,staggered center rows SA,APP-TA Min.19/32- 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 4-inch o.c.in 4-inch lap and 4-inch o.c.in four, SBS-SA,APP- Nail Base ring shank nails. equally spaced,staggered center rows (Optional)SBS-SA SA APP TA 97.5 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular W 32 Min.19/32- Nail Base ring shank nails. Note:Tin caps are to be primed with 6-inch o.c.in 4-inch lap and 6-inch o in four, (Optional)SBS-SA SBS-SA,APP- -112.5 inch plywood Mule-Hide 121 or ASTM D41 primer. equally spaced,staggered center rowss SA,APP-TA Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 8 of 22 QOTRINI-FY 'ERD TABLE lE-2: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PLATES),BONDED ROOF COVER System Deck(Note 1) Base Sheet Roof Cover(Note 15) MOP(psf) No. Base Fasten Attach Base Ply Cap TORCH-APPLIED BASE PLY: Nail Base,Polyglass G2 Base, OMG Flat Bottom Plates(square)with Roofgrip W-33 Min.19/32- CertainTeed Glasbase,Firestone #14,Dekfast Hex with Dekfast#14 or Trufast 3" 12-inch o.c.in 4-inch lap and 12-inch o.c.in two (Optional)APP-TA APP-TA -52.5 inch plywood MB Base,JM Perma-Ply 28,Tamko Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows Glass Base or GAFGLAS#75 W 34 Min.19/32- Nail Base OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in two (Optional)APP-TA APP-TA -60.0 inch plywood #12 (2),equally spaced,staggered center rows Dekfast Hex Plates with Dekfast#14,OMG 3" W-35 Min.15/32- Polyglass G2 Base,Nail Base Round Metal Plate with OMG HD,OMG Flat 10-inch o.c.in 4-inch lap and 10-inch o.c.in three (Optional)APP-TA APP-TA -75.0 inch plywood Bottom Plate(Accutrac)with Roofgrip#14 or (3),equally spaced,staggered center rows Trufast 3"Metal Insulation Plate with Trufast HD. Dekfast Hex Plates with Dekfast#14,OMG 3" W-36 Min.15/32- Polyglass G2 Base,Nail Base Round Metal Plate with OMG HD,OMG Flat 9-inch o.c.in 4-inch lap and 9-inch o.c.in four(4), (Optional)APP-TA APP-TA -90.0 inch plywood Bottom Plate(Accutrac)with Roofgrip#14 or equally spaced,staggered center rows Trufast 3"Metal Insulation Plate with Trufast HD. OMG#12 Standard Roofgrip or OMG#14 Heavy Min.15/32- 6-inch o.c.at 4-inch lap and 6-inch o.c.in three W 37 inch plywood APP Torch Base or Nail Base Duty(min.1-5/8-inch long)with OMG 3"Round (3),equally spaced,staggered center rows (Optional)APP-TA APP-TA -90.0 Metal Plates or OMG Flat Bottom Metal Plates Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c.at 4-inch lap and 6-inch o.c.in five(5), W 38 inch plywood APP Torch Base or Nail Base Duty(min.1-5/8-inch long)with OMG 3"Round equally spaced,staggered center rows (Optional)APP-TA APP-TA -120.0 Metal Plates or OMG Flat Bottom Metal Plates SELF-ADHERING BASE PLY: W 39 Min.19/32- Nail Base Dekfast Hex with Dekfast#14 or Mule-Hide 3" 12-inch o.c.in 4-inch lap and 12-inch o.c.in two, SBS-SA SBS-SA,APP-SA, -52.5* inch plywood Insulation Plate with Mule-Hide HDP Fastener equally spaced,staggered center rows APP-TA W 40 Min.19/32- Nail Base OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in two, SBS-SA SBS-SA,APP-SA, -60.0* inch plywood #12 equally spaced,staggered center rows APP-TA TABLE 1F: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck(Note 1) Primer Roof Cover(Note 15) MDP(psf) No. Joint Treatment Base Ply Ply Cap Min.15/32- (Optional)SBS-SA,APP- SBS-SA,APP-SA,APP- W-41 inch plywood (Optional)Mule-Hide 121 None SBS-SA TA TA 90.0 W 42 Min.15/32- (Optional)Mule-Hide 121 Plywood joints are covered with minimum 4-inch wide strips of SA Base Sheet, SBS-SA (Optional)SBS-SA,APP- SBS-SA,APP-SA,APP- -135.0 inch plywood rolled into place to create continuous bond. TA TA Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 9 of 22 QO TRINITY ERD TABLE 2A: STEEL OR CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Base Insulation Top Insulation Layer Roof Cover(Note 15) Deck(Note 1) MDP(psf) No. Layer Type Fasten Attach Base Ply Ply Cap Dekfast Galvalume Steel Hex with Dekfast (Optional)One or #12 DP(steel only)or Dekfast#14,OMG Min.22 ga.,type B,Grade SBS-SA, more layers,any Min.1.5-inch ACFoam II,Poly ISO AccuTrac Flat Bottom Plate with#12 1 per 2.67 (Optional)SBS-SA, SC-1. 33 steel or min.2,500 psi combination,loose 2,H-Shield,Poly ISO 1 Roofgrip(steel only)or OMG#14 Heavy ft2 SBS-SA APP TA APP-SA, -30.0 structrual concrete laid Duty,Trufast 3"Metal Insulation Plate with APP TA Trufast#12 DP(steel only)or Trufast#14 HD (Optional)One or OMG AccuTrac Flat Bottom Plate with#12 Min.22 ga.,type B,Grade SBS-SA, SC-2. 33 steel or min.2,500 psi more layers,any Min.1.5-inch H-Shield,Poly ISO 1, Roofgrip(steel only)or OMG#14 Heavy Duty 1 per 2 ftz SBS-SA (Optional)SBS-SA, APP-SA, -45.0* structrual concrete combination,loose Polytherm Trufast 3"Metal Insulation Plate with Trufast APP-TA APP-TA laid #12 DP(steel only)or Trufast#14 HD Min.22 ga.,type B,Grade (Optional)One or SBS-SA, more layers,any Min.1.5-inch H-Shield,Poly ISO 1, Dekfast Galvalume Steel Hex with Dekfast z (Optional)SBS-SA, SC-3. t steel l min.2,500 psi combination,loose Polytherm #12 DP(steel only)or Dekfast#14 1 per 2 ft SBS-SA APP TA APP-SA, 60.0 structrual concrete APP-TA laid (Optional)One or Dekfast Galvalume Steel Hex with Dekfast Min.22 ga.,type B,Grade #12(steel only)or#14 or Mule-Hide 3" SBS-SA, more layers,any Min.1.5-inch ENRGY 3,H-Shield, 1 per 1.33 (Optional)5B5-SA, SC-4. 33 steel or min.2,500 psi combination,loose Poly ISO 1,Polytherm Insulation Plate with Mule-Hide Drill Point ft2 SBS-SA APP TA APP-SA, -82.5 structrual concrete laid Fastener(steel only)or Mule-Hide HDP APP-TA Fastener Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 10 of 22 QO TRINITY ERD TABLE 2B: STEEL OR CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPED: PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS System Deck Insulation Layer(s) Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Type Attach Base Fasten Attach Base Ply Cap (psf) Min.22 ga.,type B,Grade One or more OMG Flat Bottom Plates(square)with 12-inch o.c.in 4-inch lap and 18- Prelim. Nail Base or JM Perma-Ply Roofgrip#14,Dekfast Hex with Dekfast SC-5. 33 steel or min.2,500 psi layers,any inch o.c.in two,equally spaced, (Optional)APP-TA APP-TA -45.0* structrual concrete combination Attached 28 #14 or Trufast 3"Metal Insulation Plate staggered center rows with Trufast HD Nail Base,Polyglass G2 Base, OMG Flat Bottom Plates(square)with Min.22 ga.,type B,Grade One or more Prelim. Roofgrip#14,Dekfast Hex with Dekfast CertainTeed Glasbase, 12-inch o.c.in 4-inch lap and 12- SC-6. 33 steel or min.2,500 psi layers,any Firestone MB Base,JM inch o.c.in two,equally spaced, (Optional)APP-TA APP-TA 52.5 structrual concrete combination Attached Perma-Ply 28,Tamko Glass with Trufast HD or Trufast 3"Metal Insulation Plate with staggered center rows Base or GAFGLAS#75 Min.22 ga.,type B,Grade One or more OMG Flat Bottom Plates(square)with 12-inch o.c.in 4-inch lap and 12- Prelim. Roofgrip#14,Dekfast Hex with Dekfast SBS-SA, SC-7. 33 steel or min.2,500 psi layers,any Nail Base inch o.c.in two,equally spaced, SBS-SA -52.5* structrual concrete combination Attached #14 or Mule-Hide 3"Insulation Plate staggered center rows APP-SA with Mule-Hide HDP Fastener Min.22 ga.,type B,Grade One or more 12-inch o.c.in 4-inch lap and 12- Prelim. OMG Flat Bottom Plates(square)with SC-8. 33 steel or min.2,500 psi layers,any Attached Nail Base Roofgrip#12(steel only)or#14 inch o.c.in two,equally spaced, (Optional)APP-TA APP-TA -60.0 structrual concrete combination staggered center rows Min.22 ga.,type B,Grade One or more Prelim. 12-inch o.c.in 4-inch lap and 12- SC-9. 33 steel or min.2,500 psi layers,any Nail Base OMG Flat Bottom Plates(square)with inch o.c.in two,equally spaced, SBS-SA SBS-SA, -60.0* structrual concrete combination Attached Roofgrip#12(steel only)or#14 staggered center rows APP SA Min.22 ga.,type B,Grade One or more Prelim. Dekfast isofast IF-2.375-AT Plates with 12-inch o.c.withiin the 5-inch wide, SC-10. 80 steel or min.2,500 psi layers,any Attached APP Torch S Dekfast#15 HS heat-welded side lap (Optional)APP-TA APP-TA -82.5 structrual concrete combination Min.22 ga.,type B,Grade One or more Prelim. Trufast 2.4 in.Barbed Seam Plates with 12-inch o.c.within the 6-inch wide, SC-11. 80 steel or min.2,500 psi layers,any Attached APP Torch S Trufast EHD Fasteners heat-welded side lap (Optional)APP-TA APP-TA -82.5 structrual concrete combination Min.22 ga.,type B,Grade One or more Prelim. Dekfast Hex with Dekfast#14 or OMG 12-inch o.c.within the 4-inch lap SC-12. 33 steel or min.2,500 psi layers,any APP Torch 5 Flat Bottom Plates with OMG Roofgrip and 18-inch o.c.in two,equally (Optional)APP-TA APP-TA -112.5 structrual concrete combination Attached #14 spaced,staggered center rows Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 11 of 22 QOTRINI-FY 'ERD TABLE 3A: CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 System Deck Primer Base Insulation Layer77 Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap (psf) SELF-ADHERING BASE PLY WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE: (Optional) Min.1.5-inch H-Shield,Poly ISO 1,Multi-Max (Optional)additional SBS-SA,APP-SA, C-1 Concrete Mule-Hide FA3 D-IS layers(s)of base insulation D-IS SBS-SA (Optional)SBS-SA,APP-TA APP TA -67.5 121 (Optional) (Optional)additional SBS-SA,APP-SA, C-2 Concrete Mule-Hide Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3 D-IS layers(s)of base insulation D-IS SBS-SA (Optional)SBS-SA,APP-TA APP TA -135.0 121 C-3 Concrete None Min.1.5-inch,min.1.5 pcf EPS insulation board D-IS (Optional)additional layersof base insulation D-IS SBS-SA (Optional)SBS-SA SBS-SA,APP-SA 157.5 C-4 Concrete None Min.1.5-inch,min.2.0 pcf EPS insulation board OB500 (Optional)additional layersof base insulation OB500 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA 120.0 C-5 Concrete None Min.1.5-inch ENRGY 3 OB500 (Optional)additional OB500 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -127.5 layers(s)of base insulation APP-TA C-6 Concrete None Min.1.5-inch ACFoam II,Poly ISO 2,H-Shield, OB500 (Optional)additional OB500 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -150.0 Poly ISO 1 layers(s)of base insulation APP-TA C-7 Concrete None Min.1.5-inch ACFoam II,Poly ISO 2, ENRGY 3, M-OSFA (Optional)additional M-OSFA SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -232.5 H-Shield,Poly ISO 1,Multi-Max FA3 layers(s)of base insulation APP-TA C-8 Concrete None Min.1.5-inch,min.2.0 pcf EPS insulation board CR-20 (Optional)additional layers CR-20 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -240.0 of base insulation Min.1.5-inch ACFoam II,Poly ISO 2,ACFoam III, (Optional)additional SBS-SA,APP-SA, C-9 Concrete None ENRGY 3,H-Shield,Poly ISO 1,H-Shield CG, CR-20 layers(s)of base insulation CR-20 SBS-SA (Optional)SBS-SA,APP-TA APP TA -270.0 Multi-Max FA3,ISO 95+GL C-10 Concrete None Min.2-inch ACFoam II,Poly ISO 2,H-Shield,Poly OB Classic (Optional)additional OB SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -270.0 ISO 1 layers(s)of base insulation Classic APP-TA Min.1.5-inch ACFoam II,Poly ISO 2,ACFoam III, Mule-Hide Hot (Optional)additional Hot SBS-SA,APP-SA, C-11 Concrete 121 ENRGY 3,H-Shield,Poly ISO 1,H-Shield CG, asphalt layers(s)of base insulation asphalt SBS-SA (Optional)SBS-SA,APP-TA APP-TA -480.0 Multi-Max FA3 SELF-ADHERING BASE PLY WITH BASE INSULATION AND COVERBOARD: C-12 Concrete None Min.1.5-inch Multi-Max FA3 D-IS Min.0.25-inch SECUROCK D-IS SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -67.5 Gypsum-Fiber Roof Board APP-TA Min.1.5-inch,min.2.0 pcf ASTM C578 C-13 Concrete None Ex Polystyrene,ACFoam II,Poly ISO 2, D-IS Min.0.25-inch Dens Deck Expanded Pol D-IS SBS-SA P y y Prime (Optional)56S-SA SBS-SA,APP-SA -72.5 ENRGY 3,H-Shield,Poly ISO 1 C-14 Concrete None Min.1.5-inch,min.2.0 pcf ASTM C578 D-IS Min.0.25-inch Dens Deck, D-IS SBS-SA (Optional)APP-TA APP-TA -120.0 Expanded Polystyrene Dens Deck Prime C-15 Concrete None Min.2-inch ACFoam II,Poly ISO 2,ENRGY-3,H- D-IS Min.0.25-inch SECUROCK D-IS SBS-SA SBS-SA,APP-SA, 247.5 Shield,Poly ISO 1 Gypsum-Fiber Roof Board (Optional)SBS-SA,APP-TA APP TA Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 12 of 22 QOTRINITY 'ERD TABLE 3A: CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 System Deck Primer Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap (psf) C-16 Concrete None Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3, OB500 Min.0.25-inch Dens Deck OB500 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -72.5 H-Shield,Poly ISO 1 or ISO 95+GL Prime C-17 Concrete None Min.1.5-inch ENRGY 3 OB500 Min.0.25-inch Dens Deck, OB500 SBS-SA (Optional)APP-TA APP-TA -127.5 Dens Deck Prime C-18 Concrete None Min.1.5-inch ACFoam II,Poly ISO 2,H-Shield, OB500 Min.0.25-inch Dens Deck, OB500 SBS-SA (Optional)APP-TA APP-TA -150.0 Poly ISO 1,ISO 95+GL Dens Deck Prime C-19 Concrete None Min.2-inch ACFoam II,Poly ISO 2,ENRGY-3,H- OB500 Min.0.25-inch SECUROCK OB500 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -247.5 Shield,Poly ISO 1 Gypsum-Fiber Roof Board APP-TA C-20 Concrete None Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3, M-OSFA Min.0.25-inch Dens Deck M-OSFA SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -72.5 H-Shield,Poly ISO 1,Multi-Max FA3 Prime APP-TA C-21 Concrete None Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3, M-OSFA Min.0.25-inch SECUROCK M-OSFA SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -232.5 H-Shield,Poly ISO 1,Multi-Max FA3 Gypsum-Fiber Roof Board APP-TA C-22 Concrete None Min.2-inch ACFoam II,Poly ISO 2,ENRGY-3,H- M-OSFA Min.0.25-inch SECUROCK M-OSFA SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, 247 5 Shield,Poly ISO 1 Gypsum-Fiber Roof Board APP-TA C-23 Concrete None Min.1.5-inch,min.2.0 pcf ASTM C578 CR-20 Min.0.25-inch Dens Deck CR-20 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -72.5 Expanded Polystyrene Prime C-24 Concrete None Min.1.5-inch,min.2.0 pcf ASTM C578 CR-20 Min.0.25-inch Dens Deck, CR-20 SBS-SA (Optional)APP-TA APP-TA -240.0 Expanded Polystyrene Dens Deck Prime Min.1.5-inch Ultra-Max,Multi-Max FA-3,min. Min.0.25-inch SECUROCK SBS-SA,APP-SA, C-25 Concrete None 1.3-inch ACFoam III or min.1.0-inch ISO 95+GL, CR-20 Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional)SBS-SA,APP-TA APP TA -240.0 H-Shield,Poly ISO 1,H-Shield CG,ENRGY 3 C-26 Concrete None Min.2-inch ACFoam II,Poly ISO 2,ENRGY-3,H- CR-20 Min.0.25-inch SECUROCK CR-20 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, 247 5 Shield,Poly ISO 1 Gypsum-Fiber Roof Board APP-TA C-27 Concrete None Min.2-inch ACFoam II,Poly ISO 2,H-Shield,Poly OB Classic Min.0.25-inch SECUROCK OB SBS-SA SBS-SA,APP-SA, 350.0 ISO 1 Gypsum-Fiber Roof Board Classic (Optional)SBS-SA,APP-TA APP TA Min.1.5-inch ACFoam II,Poly ISO 2,ACFoam III, C-28 Concrete Mule-Hide ENRGY 3,H-Shield,Poly ISO 1,H-Shield CG, Hot Min.um-Finch Roof Board Hot SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -350.0 121 Multi-Max FA3 asphalt Gypsum-Fiber Roof Board asphalt APP-TA TORCH APPLIED BASE PLY: C-29 Concrete None Min.2-inch ACFoam II,Poly ISO 2,H-Shield,Poly DAS Min.0.25-inch SECUROCK D-IS APP-TA (Optional)APP-TA APP-TA 232.5 ISO 1 Gypsum-Fiber Roof Board C-30 Concrete None Min.2-inch ACFoam II,Poly ISO 2,H-Shield,Poly OB500 Min.0.25-inch SECUROCK OB500 APP-TA (Optional)APP-TA APP-TA -232.5 ISO 1 Gypsum-Fiber Roof Board C-31 Concrete None Min.2-inch ACFoam II,Poly ISO 2,H-Shield,Poly M-OSFA Min.0.25-inch SECUROCK M-OSFA APP-TA (Optional)APP-TA APP-TA -232.5 ISO 1 Gypsum-Fiber Roof Board Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 13 of 22 QOTRINI-FY 'ERD TABLE 3A: CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 System Deck Primer Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap (psf) Min.1.5-inch Ultra-Max or Multi-Max FA-3, C-32 Concrete None min.1.3-inch ACFoam III or min.1.0-inch ISO CR-20 Min.0.25-inch SECUROCK CR-20 APP-TA (Optional)APP-TA APP-TA 232.5 95+GL,H-Shield,Poly ISO 1,H-Shield CG or Gypsum-Fiber Roof Board ENRGY 3 C-33 Concrete None (Optional)Min.2-inch ACFoam II,Poly ISO 2,H- OB Classic Min.0.25-inch SECUROCK OB APP-TA (Optional)APP-TA APP-TA -232.5 Shield,Poly ISO 1 Gypsum-Fiber Roof Board Classic Min.1.5-inch ACFoam II,Poly ISO 2,ACFoam III, C-34 Concrete Mule-Hide ENRGY 3,H-Shield,Poly ISO 1,H-Shield CG, Hot Min.um-Finch Roof Board Hot APP-TA (Optional)APP-TA APP-TA -232.5 121 Multi-Max FA3 asphalt Gypsum-Fiber Roof Board asphalt TABLE 3B: CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED BASE SHEET,BONDED ROOF COVER System No. Deck Primer Roof Cover(Note 15) MDP(psf) (Note 1) Base Ply Ply Cap C-35 Concrete Mule-Hide 121 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA,APP-TA -315.0 Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 14 of 22 QOTFUNrry'ERD TABLE 4A: LIGHTWEIGHT CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER Deck(Note 1) Base Insulation Layer Coverboard Roof Cover(Note 15) System MDP(psf) No. Struct. LWC Type Attach Type Attach Base Ply Ply Cap Deck SELF-ADHERING BASE PLY WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE: Min.200 psi,min Min.1.5-inch,min.2.0 pcf ASTM C578 OB500 (Optional)Additional layers 120.0 LWC-1 Concrete 2-inch Elastizell expanded polystyrene of base insulation OB500 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA Min.200 psi,min Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY OB500 (Optional)Additional layers OB500 SBS-SA (Optional)SBS-SA,APP- SBS-SA,APP-SA, 225.0 LWC-2 Concrete 2-inch Elastizell 3,ISO 95+GL,H-Shield,Poly ISO 1 of base insulation TA APP TA Min.200 psi,min. Min.1.5-inch,min.2.0 pcf ASTM C578 CR-20 (Optional)Additional layers 180.0 LWC-3 Concrete 2-inch Elastizell expanded polystyrene of base insulation CR-20 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA Min.1.5-inch ACFoam II,Poly ISO 2,ACFoam Min.200 psi,min. (Optional)Additional layers (Optional)SBS-SA,APP- SBS-SA,APP-SA, LWC-4 Concrete 2-inch Elastizell III,ENRGY 3,ISO 95+GL,H-Shield,Poly ISO 1, CR-20 of base insulation CR-20 SBS-SA TA APP-TA -180.0 H-Shield CG,Multi-Max FA3 Min.200 psi,min. Min.1.5-inch,min.2.0 pcf ASTM C578 (Optional)Additional layers LWC-5 Concrete 2-inch Celcore or expanded polystyrene CR-20 of base insulation CR-20 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -222.5 Mearlcrete Min.200 psi,min. Min.1.5-inch ACFoam II,Poly ISO 2,ACFoam (Optional)Additional layers (Optional)SBS-SA,APP- SBS-SA,APP-SA, LWC-6 Concrete 2-inch Celcore or III,ENRGY 3,ISO 95+GL,H-Shield,Poly ISO 1, CR-20 of base insulation CR-20 SBS-SA TA APP-TA 222.5 Mearlcrete H-Shield CG,Multi-Max FA3 SELF-ADHERING BASE PLY WITH BASE INSULATION AND COVERBOARD: Min.200 psi,min Min.1.5-inch,min.2.0 pcf ASTM C578 Min.0.25-inch SECUROCK (Optional)SBS-SA,APP- SBS-SA,APP-SA, LWC-7 Concrete 2-inch Elastizell expanded polystyrene OB500 Gypsum-Fiber Roof Board OB500 SBS-SA TA APP-TA 120.0 Min.200 psi,min Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY OB500 Min.0.25-inch SECUROCK OB500 SBS-SA (Optional)SBS-SA,APP- SBS-SA,APP-SA, 225.0 LWC-8 Concrete 2-inch Elastizell 3,ISO 95+GL,H-Shield,Poly ISO 1 Gypsum-Fiber Roof Board TA APP-TA Min.1.5-inch ACFoam II,Poly ISO 2,ACFoam Min.200 psi,min. III,ENRGY 3,ISO 95+GL,H-Shield,Poly ISO 1, Min.0.25-inch SECUROCK (Optional)SBS-SA,APP- SBS-SA,APP-SA, LWC-9 Concrete 2-inch Elastizell H-Shield CG,Multi-Max FA3 or min.2.0 pcf CR-20 Gypsum-Fiber Roof Board CR-20 SBS-SA TA APP TA 180.0 ASTM C578 expanded polystyrene Min.1.5-inch ACFoam II,Poly ISO 2,ACFoam Min.200 psi,min. III,ENRGY 3,ISO 95+GL,H-Shield,PolyISO 1, Min.0.25-inch SECUROCK LWC-10 Concrete 2-inch Celcore or CR-20 CR-20 SBS-SA (Optional)SBS-SA,APP- SBS-SA,APP-SA, 222 5 Mearlcrete H-Shield CG,Multi-Max FA3 or min.2.0 pcf Gypsum-Fiber Roof Board TA APP-TA ASTM C578 expanded polystyrene TORCH APPLIED BASE PLY: LWC-11 Concrete Min.200 psi,min Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY OB500 Min.0.25-inch SECUROCK OB500 BP-AA,SBS- (Optional)BP-AA,SBS- SBS-AA,SBS-TA, -225.0 2-inch Elastizell 3,ISO 95+GL,H-Shield,Poly ISO 1 Gypsum-Fiber Roof Board AA,APP-TA AA,SBS-TA or APP-TA APP-TA Min.1.5-inch ACFoam II,Poly ISO 2,ACFoam LWC-12 Concrete Min.200 psi,min. III,ENRGY 3,ISO 95+GL,H-Shield,Poly ISO 1, CR-20 Min.0.25-inch SECUROCK CR-20 BP-AA,SBS- (Optional)BP-AA,SBS- SBS-AA,SBS-TA, -180.0 2-inch Elastizell H-Shield CG,Multi-Max FA3 or min.2.0 pcf Gypsum-Fiber Roof Board AA,APP-TA AA,SBS-TA or APP-TA APP-TA ASTM C578 expanded polystyrene Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report M10000.03.08-R6 for FL30497-116 Certificate of Authorization#9503 6TR EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 15 of 22 QOTRINITY 'ERD TABLE 4A: LIGHTWEIGHT CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER System Deck(Note 1) Base Insulation Layer Coverboard Roof Cover(Note 15) No. Struct.Deck LWC Type Attach Type Attach Base Ply Ply Cap MDP(psf) Min.1.5-inch ACFoam II,Poly ISO 2,ACFoam Min.200 psi,min. III,ENRGY 3,ISO 95+GL,H-Shield,Poly ISO 1, Min.0.25-inch SECUROCK BP-AA,SBS- (Optional)BP-AA,SBS- SBS-AA,SBS-TA, LWC-13 Concrete MearI reteCelc a or H-Shield CG,Multi-Max FA3 or min.2.0 pcf CR-20 Gypsum-Fiber Roof Board CR-20 AA,APP-TA AA,SBS-TA or APP-TA APP-TA 222.5 Mearlcrete ASTM C578 expanded polystyrene TABLE 4B: LIGHTWEIGHT CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck(Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) MOP No. Struct LWC Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap (psf) Min.22 ga., Min.300 psi 7-inch o.c.at 4-inch lap Min.1.5-inch ACFoam Type B,vented GAFGLAS OMG CR and 7-inch o.c.in two, II,Poly ISO 2,H-Shield, Hot (Optional)SBS-SA, SBS-SA,APP- LWC-14 steel at max.5 ft Approved #75 BSF equally spaced center Poly ISO 1,Multi-Max asphalt None N/A SBS-SA APP-TA SA,APP-TA 45.0 cellular LWC spans rows FA3,Polytherm Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 16 of 22 QO TRINITY ERD TABLE 4C: LIGHTWEIGHT CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck(Note 1) Base Sheet Roof Cover(Note 15) MDP No. Structural Deck Lightweight Concrete Type Fasten Attach Base Ply Cap (psf) CELCORE CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min.22 ga.,type B steel at max 5 Min.225 psi,min.2-inch thick Trufast Twin 9-inch o.c.in a 4-inch lap and 18-inch o.c.in two, (Optional) LWC-15 ft spans or structural concrete Celcore MF Polyglass G2 Base,Nail Base Loc-Nail equally spaced,staggered rows in the field of the sheet APP-TA APP-TA 45.0 Min.22 ga.,type B steel at max 5 Min.225 psi,min.2-inch thick Trufast Twin 9-inch o.c.in a 4-inch lap and 18-inch o.c.in two, SBS-SA, LWC-16 ft spans or structural concrete Celcore MF Nail Base Loc-Nail equally spaced,staggered rows in the field of the sheet SBS-SA APP-SA, -45.0 APP-TA LWC-17 Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick Nail Base Trufast FM-90 8-inch o.c.in a 4-inch lap and 8-inch o.c.in three (Optional) APP-TA -60.0 ft spans or structural concrete Celcore MF equally spaced,staggered center rows APP-TA Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick 8-inch o.c.in a 4-inch lap and 8-inch o.c.in three SBS-SA, LWC-18 ft spans or structural concrete Celcore MF Nail Base Trufast FM-90 equally spaced,staggered center rows SBS-SA APP-SA, -60.0 APP-TA Polyglass G2 Base,Nail Base, GAFGLAS#75,GAFGLAS Stratavent Nailable Venting Base Sheet, Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick GAFGLAS Ply 4,GAFGLAS FlexPly 6, Trufast FM-90 7-inch o.c.in a 3-inch lap and 7-inch o.c.in two,equally LWC-19 ft spans or structural concrete Celcore 1M Perma Ply No.28,1M or OMG CR BPF spaced,staggered rows in the field of the sheet APP-TA APP-TA 75.0 Vensulation,lM GlasPly IV.GlasPly Premier.Tamko Glass-Base,Tamko Vapor-Chan LWC-20 Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick Nail Base Trufast FM-290 10-inch o.c.in a 4-inch lap and 10-inch o.c.in three (Optional) APP-TA -90.0 ft spans or structural concrete Celcore MF equally spaced,staggered center rows APP-TA ELASTIZELL CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Polyglass G2 Base,Nail Base, GAFGLAS#75,GAFGLAS Stratavent Min.0.0179-inch Tensilform S-75 Nailable Venting Base Sheet, or min.0.0205-inch Tensilform Min.200 psi,min.2-inch thick GAFGLAS Ply 4,GAFGLAS FlexPly 6, Trufast FM-90 7.5-inch o.c.in a 3-inch lap and 7.5-inch o.c.in two, LWC-21 75 at max.5 ft spans or Elastizell Range II 1M Perma Ply No.28,1M or OMG CR BPF equally spaced,staggered rows in the field of the sheet APP-TA APP-TA 30.0 structural concrete Vensulation,lM GlasPly IV.GlasPly Premier.Tamko Glass-Base,Tamko Vapor-Chan Min.0.0179-inch Tensilform S-75 SBS-SA, or min.0.0205-inch Tensilform Min.200 psi,min.2-inch thick Nail Base Trufast FM-90 7.5-inch o.c.in a 3-inch lap and 7.5-inch o.c.in two, 30.0 LWC-22 75 at max.5 ft spans or Elastizell Range II or OMG CR BPF equally spaced,staggered rows in the field of the sheet SBS-SA APP-SA, APP TA structural concrete Polyglass G2 Base,Nail Base, GAFGLAS#75,GAFGLAS Stratavent Nailable Venting Base Sheet, Min.22 ga.,type B steel at max 5 Min.200 psi,min.2-inch thick GAFGLAS Ply 4,GAFGLAS FlexPly 6, Trufast FM-90 7-inch o.c.in a 3-inch lap and 7-inch o.c.in two,equally LWC-23 ft spans or structural concrete Elastizell Range II 1M Perma PI No.28,1M APP-TA APP-TA 45.0 p g y or OMG CR BPF spaced,staggered rows in the field of the sheet Vensulation,lM GlasPly IV.GlasPly Premier.Tamko Glass-Base,Tamko Vapor-Chan Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 17 of 22 QO TRINITY ERA TABLE 4C: LIGHTWEIGHT CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck(Note 1) Base Sheet Roof Cover(Note 15) MOP No. Structural Deck Lightweight Concrete Type Fasten Attach Base Ply Cap (psf) Min.22 ga.,type B steel at max 5 Min.200 psi,min.2-inch thick Trufast FM-90 7-inch o.c.in a 3-inch lap and 7-inch o.c.in two,equally SBS-SA, LWC-24 ft spans or structural concrete Elastizell Range II Nail Base or OMG CR BPF spaced,staggered rows in the field of the sheet SBS-SA APP-SA, -45.0 APP-TA Min.350 psi,min.2-inch thick Min.22 ga.,type B vented steel Elastizell with Zell-Crete 8-inch o.c.in a 4-inch lap and 8-inch o.c.in three, (Optional) LWC-25 at max 5 ft spans or structural Fibers,supplemental attached Nail Base Trufast FM-290 equally spaced,staggered rows in the field of the sheet APP-TA APP-TA -52.5 concrete with Roofgrip#21 and 3-inch plates at 1 per 8 ft2 Min.350 psi,min.2-inch thick Elastizell with Zell-Crete Trufast Twin Min.22 ga.,type B steel at max 5 6-inch o.c.in a 4-inch lap and 6-inch o.c.in three, LWC-26 Fibers,supplemental attached Nail Base Loc-Nails(min. APP-TA APP-TA -60.0 ft spans or structural concrete with Roofgrip#21 and 3-inch 1.8-inch) equally spaced,staggered rows in the field of the sheet plates at 1 per 8 ft2 Min.350 psi,min.2-inch thick Elastizell with Zell-Crete Trufast Twin SBS-SA, Min.22 ga.,type B steel at max 5 6-inch o.c.in a 4-inch lap and 6-inch o.c.in three, LWC-27 Fibers,supplemental attached Nail Base Loc-Nails(min. SBS-SA APP-SA, -60.0 ft spans or structural concrete with Roofgrip#21 and 3-inch 1.8-inch) equally spaced,staggered rows in the field of the sheet APP TA plates at 1 per 8 ft2 MEARLCRETE CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick Polyglass G2 Base,Nail Base, Trufast FM-90 7-inch o.c.in a 4-inch lap and 7-inch o.c.in two,equally LWC-28 ft spans or structural concrete Mearlcrete Tamko Vapor Chan or OMG CR BPF spaced,staggered rows in the field of the sheet APP-TA APP-TA 45.0 Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick Trufast FM-90 7-inch o.c.in a 4-inch lap and 7-inch o.c.in two,equally SBS-SA, LWC-29 ft spans or structural concrete Mearlcrete Nail Base or OMG CR BPF spaced,staggered rows in the field of the sheet SBS-SA APP-SA, -45.0 APP-TA Nail Base, Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick Polyglass G2 Base, Trufast FM-90 7-inch o.c.in a 4-inch lap and 7-inch o.c.in two,equally BP-AA,SBS- SBS-AA, LWC-30 ft spans or structural concrete Mearlcrete GAFGLAS#75,JM Perma Ply or OMG CR BPF spaced,staggered rows in the field of the sheet AA,SBS-TA, SBS-TA,or -52.5 No.28,Tamko Glass-Base or APP-TA APP-TA Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick Trufast FM-90 7-inch o.c.in a 4-inch lap and 7-inch o.c.in two,equally SBS-SA, LWC-31 ft spans or structural concrete Mearlcrete Nail Base or OMG CR BPF spaced,staggered rows in the field of the sheet SBS-SA APP-SA, -52.5 APP-TA Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-116 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 18 of 22 Q0 TRINITY I ERD TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) No. Deck(Note 1) Type Attach Type Attach Base Ply Ply Cap MDP(psf) Min.1.5-inch ACFoam II,Poly ISO SBS-SA, Min.2.5-inch Tectum D-IS or Min.0.25-inch Dens Deck,Dens Deck Prime, (Optional)SBS-SA, CWF-1 Plank or Tectum LS Plank 2,ISO 95+GL,H-Shield,Poly ISO 1, OB500 SECUROCK Gypsum-Fiber Roof Board D-IS or OB500 SBS-SA,APP-TA APP TA APP-SA, -45.0 Polytherm,ENRGY-3 APP-TA Min.1.5-inch ACFoam ll,Poly ISO SBS-SA, Min.2.5-inch Tectum Min.0.25-inch Dens Deck,Dens Deck Prime, (Optional)SBS-SA, CWF-2 Plank or Tectum LS Plank 2,ISO 95+GL,H-Shield,Poly ISO 1, CR-20 SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA,APP-TA APP TA APP-SA, -52.5 Polytherm,ENRGY-3 APP-TA TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) MOP(psf) No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap 9-inch o.c.in 4-inch Min.1.5-inch ACFoam Min.2.5-inch ,II Poly ISO 2,ACFoam Nail Base, Trufast lap and 12-inch o.c. Min.0.25-inch Dens Deck, SBS-SA, Tectum Plank III,ISO95+GL,H-Shield, Hot Hot SBS-SA, (Optional)SBS- CWF-3 Polyglass G2 Inuldek in two,equally Dens Deck Prime,SECUROCK APP-SA, -30.0* or Tectum LS Base Loc-Nail spaced,staggered Poly ISO 1,ENRGY 3, asphalt Gypsum-Fiber Roof Board asphalt APP-TA SA,APP-TA APP-TA Plank center rows Polytherm or Multi- Max FA3, 9-inch o.c.in 4-inch Min.1.5-inch ACFoam Min.2.5-inch II,Poly ISO 2,ACFoam Nail Base, Trufast lap and 18-inch o.c. Min.0.25-inch Dens Deck, SBS-SA, Tectum Plank III,ISO95+GL,H-Shield, Hot Hot SBS-SA, (Optional)SBS- CWF-4 Polyglass G2 Twin Loc- in two,equally Dens Deck Prime,SECUROCK APP-SA, -45.0* or Tectum LS Base Nail spaced,staggered Poly ISO 1,ENRGY 3, asphalt Gypsum-Fiber Roof Board asphalt APP-TA SA,APP-TA APP-TA Plank center rows Polytherm or Multi- Max FA3, TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MOP(psf) No. (Note 1) Base Fasten Attach Base Ply Cap Min.2.5-inch Tectum 9-inch o.c.in 4-inch lap and 12-inch o.c.in two, CWF-5 Plank or Tectum LS Nail Base,Polyglass G2 Base Trufast Inuldek Loc-Nail equally spaced,staggered center rows (Optional)APP-TA APP-TA -30.0 Plank Min.2.5-inch Tectum 9-inch o.c.in 4-inch lap and 18-inch o.c.in two, CWF-6 Plank or Tectum LS Nail Base,Polyglass G2 Base Trufast Twin Loc-Nails equally spaced,staggered center rows (Optional)APP-TA APP-TA -45.0 Plank Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 19 of 22 Q0TRINrry 'ERD TABLE 6A: GYPSUM DECKS—REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP No. Deck(Note 1) Type Attach Type Attach Base Ply Ply Cap (psf) Min.1.5-inch ACFoam II,Poly G-1 Existing,sound poured ISO 2,ENRGY 3,H-Shield,Poly OB500 Min.0.25-inch Dens Deck Prime OB500 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -72.5 gypsum or gypsum plank deck ISO 1 or min.2.0 pcf,ASTM APP-TA C578 expanded polystyrene Min.1.5-inch min.2.0 pcf, Existing,sound poured (Optional)additional layers(s)of base G-2 ASTM C578 expanded OB500 OB500 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -112.5 gypsum or gypsum plank deck polystyrene insulation Min.1.5-inch ACFoam II,Poly Existing,sound poured (Optional)additional layers(s)of base SBS-SA,APP-SA, G-3 ISO 2,ENRGY 3 or H-Shield, OB500 OB500 SBS-SA (Optional)SBS-SA,APP-TA -112.5 gypsum or gypsum plank deck Poly ISO 1 insulation APP-TA Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3 or H-Shield, G 4 Existing,sound poured Poly ISO 1 or min.2.0 pcf, OB500 Min.0.25-inch SECUROCK Gypsum-Fiber OB500 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -112.5 gypsum or gypsum plank deck ASTM C578 expanded Roof Board APP-TA polystyrene Existing,sound poured Min.1.5-inch ACFoam II,Poly SBS-SA,APP-SA, G-5 gypsum or gypsum plank deck ISO 2, ENRGY 3,H-Shield,Poly M-OSFA Min.0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional)SBS-SA,APP-TA APP-TA -72.5 ISO 1 or Multi-Max FA3 Min.1.5-inch ACFoam II,Poly (Optional)additional layers(s)of base G-6 Existing,sound poured ISO 2, ENRGY 3,H-Shield,Poly M-OSFA insulation and/or min.0.25-inch SECUROCK M-OSFA SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -202.5 gypsum or gypsum plank deck ISO 1 or Multi-Max FA3 Gypsum-Fiber Roof Board APP TA Min.1.5-inch,min.2.0 pcf EPS insulation board,ACFoam II, G 7 Existing,sound poured ACFoam III,ENRGY 3,H-Shield, CR-20 Min.0.25-inch Dens Deck Prime CR-20 SBS-SA SBS-SA,APP-SA, gypsum or gypsum plank deck (Optional)SBS-SA,APP-TA APP TA -72.5 Poly ISO 1,H-Shield CG or Multi-Max FA3 G 8 Existing,sound poured Min.1.5-inch,min.2.0 pcf EPS CR-20 (Optional)additional layers of base CR-20 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -240.0 gypsum or gypsum plank deck insulation board insulation G-9 Existing,sound poured Min.1.5-inch,min.2.0 pcf EPS CR-20 Min.0.25-inch SECUROCK Gypsum-Fiber CR-20 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -240.0 gypsum or gypsum plank deck insulation board Roof Board APP-TA Min.1.5-inch ACFoam II,Poly (Optional)additional layers(s)of base G-10 Existing,sound poured ISO 2,ACFoam III,ENRGY 3,H- CR-20 insulation and/or min.0.25-inch SECUROCK CR-20 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA, -257.5 gypsum or gypsum plank deck Shield,Poly ISO 1,H-Shield CG Gypsum-Fiber Roof Board APP TA or Multi-Max FA3 Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 20 of 22 QO TRINITY ERD TABLE 6B: GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP(psf) No. (Note 1) Base Fasten Attach Base Ply Cap Existing sound poured gypsum Trufast FM-75 or FM-90 9-inch o.c.in 4-inch lap and 18-inch o.c.in * G-11 or gypsum plank deck Nail Base,Polyglass G2 Base or Twin Loc-Nails two,equally spaced,staggered center rows (Optional)APP-TA APP-TA 45.0 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER System Substrate Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP No. (Notes 1&11) Type Attach Type Attach Base Ply Ply cap (psf) SELF-ADHERING BASE PLY: (Optional)additional layers(s)of base R-1 Existing Min.1.5-inch Multi-Max FA3 D-IS insulation and/or min.0.25-inch SECUROCK D-IS SBS-SA (Optional)SBS-SA,APP-TA S ,APP-TA APP- asphaltic roof SA,AP -67.5 Gypsum-Fiber Roof Board Existing Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3 or SBS-SA,APP- R 2 asphaltic roof Multi-Max FA3 or min.2.0 pcf EPS insulation D-IS Min.0.25-inch Dens Deck Prime D-IS SBS-SA (Optional)SBS-SA,APP-TA SA,APP-TA 72.5 board Existing (Optional)additional layers(s)of base R-3 asphaltic roof Min.1.5-inch min.2.0 pcf EPS insulation board D-IS insulation D-IS SBS-SA (Optional)SBS-SA SBS-SA,APP-SA 90.0 R 4 Existing Min.1.5-inch min.2.0 pcf EPS insulation board D-IS Min.0.25-inch SECUROCK Gypsum-Fiber Roof D-IS SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP-SA -90.0 asphaltic roof Board (Optional)additional layers(s)of base R-5 Existing Min.1.5-inch ACFoam II,Poly ISO 2 or ENRGY 3 D-IS insulation and/or min.0.25-inch SECUROCK D-IS SBS-SA (Optional)SBS-SA,APP-TA S ,APP-TA APP- asphaltic roof SA,AP -90.0 Gypsum-Fiber Roof Board Existing Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3,H- SBS-SA,APP- R-6 asphaltic roof Shield,Poly ISO 1 or min.2.0 pcf EPS insulation OB500 Min.0.25-inch Dens Deck Prime OB500 SBS-SA (Optional)SBS-SA,APP-TA SA APP TA -72.5 board R 7 Existing Min.1.5-inch,min.2.0 pcf EPS insulation board OB500 (Optional)additional layers of base insulation OB500 SBS-SA asphaltic roof p ( p ) y (Optional)SBS-SA SBS-SA,APP-SA 120.0 R 8 Existing Min.1.5-inch,min.2.0 pcf EPS insulation board OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP- -120.0 asphaltic roof Board SA,APP-TA (Optional)additional layers(s)of base R 9 asphaltic roof H-Shield, Poly ISO 1 SA,AP Existing Min. inch ACFoam II,Poly ISO 2,ENRGY 3 or OB500 insulation and/or min.0.25-inch SECUROCK OB500 SBS-SA (Optional)SBS-SA,APP-TA S ,APP-TA APP- -127.5 Gypsum-Fiber Roof Board R-10 Existing Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3,H- M-OSFA Min.0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP- 72 5 asphaltic roof Shield,Poly ISO 1 or Multi-Max FA3 SA,APP-TA (Optional)additional layers(s)of base R-11 Existing Min.1.5oly I ACFoam ul Poly ISO 3 ENRGY 3,H- M-OSFA insulation and/or min.0.25-inch SECUROCK M-OSFA SBS-SA (Optional)SBS-SA,APP-TA SA,AP APP- -157.5 asphaltic roof Shield,Poly ISO 1 or Multi-Max FA3 Gypsum-Fiber Roof Board SA,APP-TA Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-116 for F1.30497-116 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 21 of 22 QO TRINITY ERA TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER System Substrate Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP No. (Notes 1&12) Type Attach Type Attach Base Ply Ply Cap (psf) Min.1.5-inch min.2.0 pcf ASTM C578 expanded polystyrene, Min.2-inch ACFoam II,Poly ISO 2, R-12 Existing min.1.5-inch Ultra-Max or Multi-Max FA-3,min. CR-20 Min.0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional)SBS-SA,APP-TA S ,APP-TA APP- SAA, PP 72 5 asphaltic roof 1.3-inch ACFoam III or min.1.0-inch ISO 95+GL, H-Shield,Poly ISO 1,H-Shield CG or ENRGY 3 Existing Min.1.5-inch min.2.0 pcf ASTM C578 expanded (Optional)additional layers(s)of base R-13 CR-20 CR-20 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA 240.0 asphaltic roof polystyrene insulation R-14 Existing Min.1.5-inch min.2.0 pcf ASTM C578 expanded CR-20 Min.0.25-inch SECUROCK Gypsum-Fiber Roof CR-20 SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP- -240.0 asphaltic roof polystyrene Board SA,APP-TA Min.1.5-inch Ultra-Max or Multi-Max FA-3,min. (Optional)additional layers(s)of base R-15 Existing 1.3-inch ACFoam III or min.1.0-inch ISO 95+GL, CR-20 insulation and/or min.0.25-inch SECUROCK CR-20 SBS-SA (Optional)SBS-SA,APP-TA S ,APP-TA APP- SAA, -240.0 asphaltic roof H-Shield,Poly ISO 1,H-Shield CG or ENRGY 3 Gypsum-Fiber Roof Board (Optional)additional layers(s)of base R-16 Existing Min.2-inch ACFoam II,Poly ISO 2,ENRGY-3 or H- CR-20 insulation and/or min.0.25-inch SECUROCK CR-20 SBS-SA (Optional)SBS-SA,APP-TA S ,APP-TA APP- asphaltic roof Shield,Poly ISO 1 SA, 247 5 Gypsum-Fiber Roof Board TORCH-APPLIED BASE PLY: R-17 Existing Min.1.5-inch Multi-Max FA3 D-IS Min.0.25-inch Dens Deck,Dens Deck Prime or D-IS APP-TA (Optional)APP-TA APP-TA -67.5 asphaltic roof SECUROCK Gypsum-Fiber Roof Board R-18 Existing Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3 or D-IS Min.0.25-inch Dens Deck,Dens Deck Prime or D-IS APP-TA (Optional)APP-TA APP-TA -90.0 asphaltic roof min.2.0 pcf EPS insulation board SECUROCK Gypsum-Fiber Roof Board R-19 Existing Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3,H- OB500 Min.0.25-inch Dens Deck,Dens Deck Prime or OB500 APP-TA (Optional)APP-TA APP-TA -127.5 asphaltic roof Shield,Poly ISO 1 or ISO 95+GL SECUROCK Gypsum-Fiber Roof Board R-20 Existing Min.1.5-inch ACFoam II,Poly ISO 2,ENRGY 3,H- M-OSFA Min.0.25-inch SECUROCK Gypsum-Fiber Roof M-OSFA APP-TA (Optional)APP-TA APP-TA -157.5 asphaltic roof Shield,Poly ISO 1 or Multi-Max FA3 Board Min.1.5-inch Ultra-Max or Multi-Max FA-3,min. R-21 Existing 1.3-inch ACFoam III or min.1.0-inch ISO 95+GL, CR-20 Min.0.25-inch SECUROCK Gypsum-Fiber Roof CR-20 APP-TA (Optional)APP-TA APP-TA -232.5 asphaltic roof H-Shield,Poly ISO 1,H-Shield CG or ENRGY 3 or Board min.2.0 pcf ASTM C578 expanded polystyrene Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by: Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 22 of 22