HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulatir-Re T"Irlo7rice.Method
Project Name: KING
Builder Nam ' AUG 2 ® 2020
Street: 217 SCHOONER LANE
Permit Office
City, State, Zip: DUCK KEY, FL,
Permit Numb r
ST. Lucie County, Permitting
Owner.
Jurisdiction:
Design Location: FL, Key West
County: Monme (Florida Climate Zone 1
1. New construction or existing New (From Plans)
9. Wall Types (1580.0 sgft:)
insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1580.00 ft2
b. N/A
R= ft23.
Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 3
d. WA
11 ft2
5: is this a worst case? No
J0. Ceiling Types (1648.0 sgft.)
a. Roof Deck (Unvented).
Insulation Area
R=30.0 1648.00 ft2
6. Conditioned floor area above grade (ftJ 1648
b. NIA
R= f12
Conditioned floor area below grade (ft2) 0
c.t IA
ti. Ducts
R= ft2
R ft2
7. Windows(220:0 sgft.) Description Area
a. Sup: Attic. Rat Attic, AH: ZONE 1
6 309.6
a. U-Factor. Sgl, U=1.07 220.00f?
SHGC: SHGC=0.25
b. U-Factor. NIA ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
36.0 SEER:18.00
c. U-Factor. NIA ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. NIA ft2
a. Electric Heat Pump
25.0 HSPF.9.60
SHGC:
Area Weighted Average Overhang Depth: 3.036 ft.
Area Weighted, Average SHGC: 0.250
14. Hot water systems
; a. Natural Gas
Cap: 50 gallons
8. Floor Type_ s (1648.0 sgft.) Insulation Area
EF: 0:590
a. Raised Floor R=19.0 1548.00 ft2
b. Conservation features
b. N/A R= ft
None
c. NIA R= fF
15. Credits
Pstat
Glass/Floor Area: 0.142 Total Proposed Modified Loads: 63.80
PASS
Total Baseline Loads: 93.35
I hereby certify that the plans and. specifications covered by
Review of the plans and
O�-flAESTAT�
this calculation are in compliance with the Florida En
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code,
PREPARED BY:
Before construction is completed
DATE:
th'i's building will be inspected for
0 f ,41
compliance with Section 553.908.
• ° 4
I hereby certify that this building, as designed, is in compliance
Florida Energy Code.
Florida Statutes.
COb
with the
WE
OWNER/AGENT: - _._.__
BUILDING OFFICIAL:
DATE:
DATE:
--
_ _
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2Z1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than a .68 ACII (R402.4.1.2).
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance -with ANSURESNI ICC 380, is not greater than 0.030 On for whole house.
FILE COPY
102020 8:24 AM EnergyGaugeO USA 6.0:02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE. LEVEL (EPL) DiSPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 68
The lower the EnergyPerformance index, the more efficient the home.
1. New home or, addition
1..New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. _$ingie-family
b) Return ducts R
6.0
c) AHU location
ZONE 1
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
36.0
a) Split system SEER
5. Is this a worst case? .(yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP.
6. Conditioned floor area (sq. ft)
6. 1548.
d) Room unit/PTAC EER
e) Other
18.0
7. Windows, type and area
a) U-factor.(weighted average) 7a. 1.070
b)'Solar Heat Gain Coef icient:(SHGC) 7b. 0.250
c) Area 7c. 220.0
& Skylights
a) U=factor:(weighted average) Be. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9.. Floor type; insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type.and insulation:
A. Exterior
1. Wood frame (Insulation R-value)
2. Masonry.(Insulation R-value)
B. Adjacent:
1. Wood frame (ihwlatlon R=value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single;assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a.
9b.. 19.0
9c.
10A1.
10A2.. 4.1
1os1.
10B2.
11 a. 30.0
11 b.
l l c.
lld. No
14. Heating system: Capacity25.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP..
d) Gas furnace, natural gas AFUE
e) Gas furnace,.LPG AFUE
4 Other 9.60
15. Water heating system
a) Electric resistance EF
b) Gas fired, natural gas EF _ 0:59
c).Gas fired, LPG' EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
0 Heat recovery unit HeatRee/*
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Muitizone cooling credit
a) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1 3 of the Florlda Building Code, Energy Conservation,. if not DEFAULT.
[certify that this home has compiled with the Florida Building Cone, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection: Otherwise, anew EPL
display card will be completed based on installed :code compliant features.
Builder Signature: Date:
Address of New Home: 217 SCHOONER LANE City/FL Zip: DUCKKEY, FL
11=020 8:24 19 AM EnergyGaugeD USA 6.0.03 (Rev, 1) - FIaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017 INPI IT All IMMARV f _I41=f _K1 1CT 1 MOritDT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office;
Jurisdiction:
Family Type:
New/Existing:
Comment:
KING
User
1
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 1548
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
BlocklSubdivislon:
PlatBook:
Street: 211 SCHOONER LANE
County: Monroe
City, State, Zip: DUCK KEY,
FL,
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Key West Fl_KEY WEST tNTL A 57 90
70 75 6&5 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1548 15480
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfiIID Finished Cooled Heated
1
ZONE 1
1W 15480 Yes 3
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space R_Value
Area Tile Wood Carpet
1 Raised Floor
ZONE 1 -- - ___-
1648W 19 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Bari• Absor. Tested Tested Insul. (deg)
1
Hip
Metal 1677 ft2 0 ft2 Medium
N 0.96 No 0.9 No 30 22.6
ATTIC
#
Type
Ventilation Vent Ratio,(1 In)
Area RBS IRCC
1
Full attic
Unvented 0 1548 ft2 N N
CEILING
#
Ceiling Type
Space RValue Ins Type Area Framing Frac Truss Type
1
Under Attic(Unvented)
ZONE-1 30 Blown
154812 0.11 Wood
102020 8:24 AM fnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHFCKLIST RFPnRT
WALLS
Adjacent
Space
Cavity Width Height Sheathing Framing Solar
Below
Omt
To WatL'Lype_
R-value Ft In_._._Ft-in______Area,- R-Value_F-raction_ . bsor-_GradeVa.-
1 NW
Exterior Concrete Block - Int Insul ZONE 1
4.0999 43 10
430.0 IF 4.1
0 0.75
0
-2 SE
Exterior Concrete Block - Int Insul ZONE 1
4.0999 43 10
430.0 ft; 4.1
0 0:75
0
_ 3 SW
Exterior Concrete.Block- Int Insul ZONE 1
4.0999 36 10
360.0 ft2 4.1
0 0.75
0
4 NE
Exterior Concrete Block - Int Insul ZONE 1
4.0999 36 10
360.0 ft= 4.1
0 0.75
0
DOORS
#
Omt D"oorType
Space
Storms
U=Value Width
Height
Area
Ft In
Ft In
1
NW Insulated
ZONE 1
None
.46 15
8
120 W
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Omt ID Frame Panes
NFRC
U-Factor SHGC Imp
Area Depth Separation
Int Shade
Screening
1
SW 3 Metal Low-E Single
Yes
1.07 0.25 Y
30.0 W 1 R 0 in 1 ft 0 in
Drapes/blinds
None
2
SW 3 Metal Low-E Single
Yes
1.07 0.25 Y
4.0 W 1 ft 0 in 1 ft 0 in
Drapes/blinds
None
3
SW 3 Metal Low=E Single
Yes
1.07 0.25 Y
8.0 ftZ 1 ft 0 in 1 ft 0 in
Drapes/blinds
None
4
NW 1 Metal, Low-E Single
Yes
1.07 0.25 Y
32.0 ft2 10 ft 0 in 1 ft 0 in
Drapes/blinds
None
5
NE 4 Metal Low-E Single
Yes
1.07 0.25 Y
30.0 ft2 1 ft 0 in 1 ft 0. in
Drapes/blinds
None
6
NE 4 Metal Low-E Single
Yes
1.07 0.25 Y
24.0 ft' 1 ft 0 in 1 ft 0 In
Drapes/blinds
None
7
NE 4 Metal Low-E Single
Yes
1.07 0:25 Y
30.0 ft' 1 ft.0 in 1 ft 0 in
Drapes/blinds
None
8
SE2 Metal Low-E Single
Yes
1.07 0.25 Y
30.6 ft' 1 ft 0 In 1 ft 0 in
Drapes/blinds
None
9
SE 2 Metal Low-E Single
Yes
1.07 0.25 Y
32.0 ft= 6 ft 0 in 1 ft 0 in
Drapes/blinds
None
INFILTRATION
# Scope
Method
SLA CFM 50 EL A EgLA ACH ACH 50
1 Wholehouse Proposed CFM(50) .000296
1200 65.98 123.89 .1568 4.6512
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
None
HSPF:9.6
25kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficlency
Capacity Air Flow
SHR Block
Ducts
1
CentrahUnit/
None
SEER: 18.
36 kBtu/hr 1080 cfm
0.75 1
sys#1
1/2/2020 8:24 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC.6th Edition (2017) Compliant Software Page 3 of 4
FnRM R41715_2n17 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Natural Gas
None
ZONE 1
0.59 50 gal
60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
�
w
ft=
DUCTS
— Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
# Location R:Value Area
Location
Area Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic
6 309.6 ft
Attic.
77A ft' Prop. Leak Free
ZONE 1
— cfm
46A cfm 0.03
0.50
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinJan HFeb
W Mar
MarWApr
A r
Ma Jun Jul.
Au
Se
Sep
Oct
WOct MNov
Nov
Dec
HDecVenting
Jan Feb
Mar
May Jun Jul
Aug
Thermostat Schedule; HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
80
80 78 78
78
78
78
78
78
78
Cooling (IIUEH) AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
80
80 78 78
78
78
78
78
78
78
Heating (WD) M
68
68
68
68 68 68
68
68
68
68
68
68
Heating(WEH) AM
65
65
65
65 65 65
65
68
68
68
68
68
PM
68
68
68
68 68 68
68
.68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture: Fraction
Space
Default 81bs1s JL
Oft'
Oft,
0.3
ZONE 1