FOUNDATION PLAN
GENERAL FOUNDATION LEGEND
(NOT ALL DESIGNATIONS AND NOTES APPLY TO THIS JOB)
FOUNDATION FOOTINGS
F-1
12"xl2" THICKENED EDGEW/ 1-#5 CON).
F-2
IS"x I6" MONOLITHIC FOOTING W/ 2-#5 CONT,
F-3
3'-&' x V-0" x 16" DEEP FOOTING W/ #5s AT 6" O.C. EACH WAY
CONCRETE COLUMNS -
G-I
A
8" x S" CMU W/ 1-#5 VERT. GROUTED SOLID AT48" O.G. (24" O.G.
FOR 2 OR MORE STORIES.
G-2 ®®
8" x I6" CMU W/ 1-#5 VERT. EACH CELL' GROUTED. SOLID
G-3
12' x 12' CMU '0' BLOCK W/ 4-#5 VERT. GROUTED SOLID
CONCRETE BEAMS
5-1
PERIMETER BOND BEAM PRECAST LINTELS - SEE CAST CRETE SCHEDULE
5-2
8"x 16" POURED GONG. BEAM W/ 4-#5s CONT.
INDICATES NEW 8" CMU WALL W/ FILLED CELLS AT-48" O.C. `
INDICATES NEW CONCRETE LINTEL - SEE CAST CRETE SCHEDULE
SF-
GENERAL FOUNDATION NOTE
(NOT ALL NOTES ARE SPECIFIC TO THIS JOB)
I. CONTRACTOR TO VERIFY ALL INTERIOR BEARING WALL. FT' S W/ ROOF
TRUSS MANUFACTURER
2. SOIL BEARING VALUES. FOUNDATION DESIGNS SHOWN' HERE ARE BASED
ON A SOIL BEARING VALUE OF 2,500 P.S.F. FOUNDATIONS AND SLABS
ARE DESIGNED TO UNIFORMLY BEAR ON WELL DRAINED NON -EXPANSIVE
SOILS. SOILS SHALL BE COMPACTED TO S511e MIN. OF MODIFIED PROCTOR
TEST. A CERTIFIED SOILS ENGINEER SHALL CONDUCT ON SITE BORINGS
AT LOCATIONS SPECIFIED BY THE STRUCTURAL ENGINEER.' THE SOILS
ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS,
AND COMPARE WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS.
SHOULD ON -SITE OBSERVATIONS SHOW THAT FOOTINGS SHOWN HERE
ARE NOT SATISFACTORY, THE STRUCTURAL ENGINEER AND ENGINEER
SHALL BE CONTACTED IMMEDIATELY FOR NEW DESIGNS.
3, CONTRACTOR TO VERIFY SOIL DENSITY AS PER GEO-TECHNICAL
ENGINEERING SOC. PRIOR TO CONCRETE PLACEMENT.
4. ALL REBAR TO HAVE A MIN LAP (48x BAR DIA)AT ALL JOINTS AND
CORNERS
5. INDICATES LOAD BEARING 2x 6 OR 2x8 STUD WALL AT 16" O.G. TYP. U.N.O.
REFER TO TYP DETAIL. -
6. MINIMUM FOOTING PENETRATION. EXTEND BOTTOM OF ALL FOUNDATIONS
AT PERIMETER OF BUILDING 12" MINIMUM BELOW FINISHED GRADE
7. CONCRETE STRENGTH. MINIMUM CONCRETE STRENGTH FOR ALL SLABS
PATIOS, AND FOUNDATIONS SHALL BE MINIMUM 3000 PSI AFTER 215
DAYS. PROVIDE TEST REPORTS ON EACH BUILDING FOR THE OWNERS
RECORD AND ACCESSIBLE TO THE ENGINEER'
S. EXPANSION JOINT. PROVIDE 112" THICK x 4" WIDE BITUMINOUS EXPANSION
JOINT MATERIAL AT ALL SURFACES WHERE EXIST'G SLABS ABUT TO NEW
SLABS.
9. PATIO SLABS. PROVIDE 4" THICK CONCRETE SLABS REINFORCED WITH
6Xb 10/10 WELDED MESH. PLACE SLABS OVER TERMITE TREATED, WELL
COMPACTED SOIL AND 6-MIL VISQUEEN VAPOR BARRIER. SLOPE PATIO
SLABS AWAY FROM BUILDING.
10. SLAB FINISH. PROVIDE STEEL TROWEL FINISH ALL INTERIOR SLAB AREAS
INCLUDING GARAGES. CREATE BROOM FINISH TEXTURE FOR ALL EXTERIOR
WITHVERIFYALL(' MASONRY OPENIN�S II. ALL CONCRETE BEAMS (P.C, LINTELS) BY GASTGRETE OR EQUAL.
UJITH WINDOW AND DOOR MANU 12. VERIFY ALL WALL OPENINGS WITH WINDOW AND DOOR MANUFACTURER'S
SPECIFICATIONS.
EXACT
SIZES.' m PROVIDE RECESSES IN SLAB AS REQUIRED FOR ALL EXTERIOR DOORS
VERIFY RECESS WITH MANUFACTURER)
9
N
3' 0"
WLG•
Q
3068
3068CLG.
M
BATH
7
4.1
3068
3068
BF
PKT DR
F1KT DR
5F
o - 3'-4"
3
BUILT IN
3.1 -
O PKT DR
BEDRM 2
REF
n
BEDRM
I
a�
4;
KITCHEN
-
0
121-m
-
lot.011°
12'-0"
0
0
b
t+l
N
C
COVERE
ENTRY
GREAT RM
j
EM. EGRESS
"t
-
0
�
FLOOR PLAN
I
DOOR SCHEDULE' -
"ANTITY1CODE�TYPE1
M.O. SIZES
NOTES
I
PR3068
SWING
1 74, X SO'
FRENCH DOORS (I.R)
# - REVISION DATE BY
GENERAL NOTES;
NOTE: DO NOT SCALE DRAWINGS USE FIGURED DIMENSIONS ONLY
I. ALL WORK SHALL COMPLY WITH 2017 FLORIDA RESIDENTIAL BUILDING CODE AS ADOPTED
BY THE LOCAL COUNTY AND AS APPLICABLE TO THE AREA IN WHICH THE
_
BUILDING IS TO BE CONSTRUCTED WITH ALL APPLICABLE AMENDMENTS.
2. VERIFY ALL DIMENSIONS AND EXISTING/ NEW CONDITIONS IN THE FIELD PRIOR TO
CONSTRUCTION, REPORT ANY DISCREPANCIES TO ENGINEER IN WRITING IMMEDIATELY
RICK Boverre CONSULTING INC.
PRIOR TO ANY WORK FOR REVISION AS REQUIRED. ENGINEER TAKES NO RESPONSIBILITY
COA #9707
FOR CONTRACTORS OR SUB -CONTRACTORS NOT REPORTING DISCREPANCIES PRIOR TO
CONSTRUCTION. -
(SEE
RICHARD BOYETTE
FOUNDATION PLAN FOR ALL GENERAL FOUNDATION NOTES)
FL PE #42485
(SEE ROOF/ FRAMING PLAN FOR ALL GENERAL NOTES)
(SEE AIR CONDITIONING lI PLAN FOR L L GENERA AIRGONDi T IONING NOTES)
4031 COCONUT BLVD
NU
ROYAL PAL M BCH., FL 33411
(SEE ELECTRICAL PLAN FOR ALL ENERAL ELECTRICAL NOTES)
3. EXTERIOR WALLS TO BE NOMINAL 8" MASONRY CONSTRUCTION w/ I"x2" P.T: FURRING STRIPS
561-
AT MAX. 16o.c. FOR CMU CONSTRUCTION
DATE:
4. EXTERIOR WOOD WALLS TO BE NOMINAL 2x6 OR 2x8 P.T. WOOD FRRAMING AT 16" O.G.
S. INTERIOR (NON -LOAD BEARING WALLS TO BE 3%" x 25 GA METAL STUDS AT I6" O.G.
UNLESS NOTED OTHERWISE.
6. ALL WOOD FRAMING IN CONTACT WITH CONCRETE SHALL BE SEPARATED WITH A MIN. 15#
FELT OR BE PRESSURE TREATED WOOD (RT.)
7. ALL CBS WALLS TO RECEIVE APPROVED R-4.2 (MIN.) INSULATION (PROVIDE R-5 IF UNDER
600 S.F. ADDITION). WOOD WALLS TO RECEIVE R-II (MIN.) BATT INSULATION AND ALL
ATTIC SPACES TO RECEIVE R-30 (MIN.) BATT INSULATION FOR ALL CONDITIONED SPACES.
CONTRACTOR TO VERIFY WITH ENERGY CODE CALLS.
8 . WINDOWS TO BE ALUMINUM FRAME P.G.T. (UNLESS NOTED OTHERWISE) WITH TINTED GLASS
INSTALL PER MANUFACTURERS RECOMMENDED INSTALLATION INSTRUCTIONS AND ALL
LOCAL CODES.
9 CAULK AND SEAL ALL WINDOWS AND DOOR OPENINGS. SEAL JOINTS BETWEEN
DISSIMILAR MATERIALS AS REQUIRED.
10. WET AREA WALLS (TUB AND SHOWER AREAS)TO HAVE 1/2" MR DRYWALL OR EQUAL
IL 11/2"4 CARRIAGE BOLTS SHALL BE USED IN LIEU OF NAILS IN 'SIMPSON' POST CAPS $ BASES.
12. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE GOVERNING ENERGY CODE AND IF
APPLICABLE, BUILD IN ACCORDANCE WITH ALL PROVISIONS OF THIS CODE
13. THE: CONTRACTOR SHALL BE TOTALLY RESPONSIBLE FOR ALL MEANS AND METHODS
OF CONSTRUCTION. THE ENGINEERS PERIODIC VISITS TO THE SITE SHALL NOT RELIEVE
THE CONTRACTOR OF ANY RESPONSIBILITY AND HE/SHE ALONE SHALL BE HELD LIABLE
FOR ANY AND ALL LITIGATION ARISING FROM INJURY.
14. ALL BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING
CONDITIONS AND SATISFY THEMSELVES AS TO THE EQUIPMENT OR MATERIALS REQUIRED,
OR FOR DIFFICULTIES OF A BID WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN
EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, ENCOUNTERED WHICH COULD
HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED.
15. ALL WORK TO BE IN COMPLETE WORKING ORDER, IN PLACE, AND READY FOR USE,
16. CONTRACTOR SHALL PROVIDE ENGINEER WITH SHOP DRAWINGS FOR ALL ITEMS
THAT REQUIRE FABRICATION.
17. THE CONTRACTOR OR OWNER IS RESPONSIBLE FOR THE ADEQUATE
BRACING OF ALL STRUCTURAL AND NONSTRUCTURAL COMPONENTS DURING CONSTRUCTION.
16. ALL DEBRIS/'TRASH TO BE REMOVED FROM JOB SITE AT CONTRACTORS EXPENSE.
IS. CONTRACTOR TO SUBMIT PRODUCT APPROVALS FOR - WINDOWS, DOORS, ROOF MATERIAL,
ti
CONC. LINTELS, SHUTTERS, ETC. TO ENGINEER FOR APPROVAL.
h--1
WINDOW SCHEDULE - BASED ON PGT SIZES
#
QUANTITY
GODS
TYPE
M.O. SIZES
NOTES
A
4
4053
S.H.
48%" X 63""
IMPACT RESISTANT
8
4
25
S.H.
37si4" X &V'
EGRESS AT BEDROOMS (I.R)
C,
1
23
S.N.
37'i4" X 3&%"
TEMP. OBSCURE (I.R.)
GENERAL WALL LEGEND
NEW S" CMU WALL W/ FILLED CELL AT
48' O.G. (24' O.G. FOR 2 STORY) W/ I-45
FILLED SOLID. PROVIDE 2 LAYERS 5/8"
STUCCO @ PAINT (COLOR SELECTED
BY OWNER INTERIOR TO RECEIVE
I" FURRING STRIPS AT 16"` O.C. W/ R-42
FOIL BACKED INSULATION AND 1/2"
DRYWALL FINISHED AND PAINTED
3 Y x 25 GAGE METAL STUDS
INTERIOR WALL AT 16 O.C. W/ 1/2"
DRYWALL AT EACH SIDE, FINISHED AND
PAINTED, COLOR BY OWNER
PROJECT DATA:
-SQUARE- FOo,-7�,
LIVING AREA I/065 SQ. FT.
COVERED ENTRY 123 SQ, FT,
NEW TOTAL UNDER ROOF 1,1,86 SQ. FT,
DESIGN PARAMETERS:
F.B.C.2017 RESIDENTIAL
ASCE 7-10
BASIC WIND SPEED 170 MPH 3 S U vU 132 H VA
BASIC WIND VELOCITY PRESSURE: 32.1 PSF
WIND EXPOSURE CLASSIFICATION 'C
RISK CATEGORY 2
OCCUPANCY USE/ TYPE: SINGLE FAMILY DWELLING - R3
DETACHED ACCESSORY DWELLING STRUCTURE
CONSTRUCTION TYPE: V15
# OP STORIES: I
DESIGN AS:
I. ENCLOSED x
MEAN ROOF HEIGHT - 330' MAX.
TOTAL ROOF LIVE LOAD - 30PSF
TOTAL ROOF DEAD LOAD -17 PSF
BOTTOM CHORD DEAD LOAD 10 PSF
MIN. SOIL BEARING PRESSURE - 2500 PSF
CODES FOiR REFERENCE.
2017 PLORIDA BUILDING CODE RESIDENTIAL
2017 FLORIDA MECHANICAL $ PLUMBING CODE
2014 NFPA (NEC)
2017 NFPA-72
(ALL LOCAL AND STATE AMENDMENTS)
PA Z
o.
This document has been digitally signed by Richard
Boyette, FL PE 42485 on 6/30/2020 using an SHA-1
I
authentication code. Printed copies of this document
w
are not considered signed and sealed and the SHA-1
Saint Lucie Building Department Product 4pproval Submittal 4ffielavit
Permit # Building 72513 S. INDIAN RIVER DRIVE: Contractor:
Opening Schedule: Swing Doors, Overhead
Doors, Sliding Doors, Fixed Glass, Windows @ Skylights
FL # or
Miami -Dade
Product
Model #
-Manufacturer
Glass
Description
Attache=ment.Method Type, Size
Spacing 8 Embedment
Buifding Design
Pressure
Product Design
Pressure
FL-15180.4
EXT. DOOR
Series N
Plast Pro
IMPACT
1/4"0 X 2'i2" tapcon 4" o.c, min. Ilia" embed.
+36.1/ -47.3
+50.0/ - 50.1D
I6-0714.06
WINDOW
SH-700 -
PGT
IMPACT
�/a m X 2''2" tapcon 12" o.c, min. P/4" embed.
+37.0/ -50.6
Product
Model #
Manufacturer
Attache=ment Method Type, Size;
Spacing, Embedment 8 Stiffener etc.
Bulidin en
Pr re
Product gn
P e
Mullions
MULLION
PGT
IMPACT
PER MANUFACTURERS INSTALLATION INSTRCUTION
17-0630.01
Clipped Extruded
Roof
ASPHALT SHINGLE ROOF
Siding
Soffit
Hurricane Panels
less than 6' span
Gauge of steel
Hurricane Panels
6' span or more
Gauge of steel
authentication code must be verified on any electronic ® LL9
copies. >