HomeMy WebLinkAboutBuilding Plansm
m
■i
b/ b.. thrCK cut coral
finished stucco bands
Gulf Coast Supplg and MPG 5v Crimp Metal roofing FL #II651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #4 x 1.5"
wood screws with self sealing washer at 12' o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment metalled with min. 4 side laps and V and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
paled L� o_c_at_all laps and two AstaggeredLrows 12' o.c. in field. Attach
RIGHT
carol riniSrlea stucco Danes
SCALE: 1/4' - P—O'
?ulf Coast Supplg roofing FL MFG 5v Crimp Metal roofFL #11451.12
L gga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5'
uood screws with self sealing washer at 12' ol max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 side laps and 6" and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. at all laps and two staggered rows 12' o.c. in field. Attach
deck to trusses using attachment detai on this sheet
Gulf Coast Supplg and MPG 5v Crimp Metal roofing FL #IIL51.12
2L ga. 5v crimp metal roofing attached to pigwood deck using #4 x 15'
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb,felt underlagment installed with mm. 4 ode laps and V and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced V o.c. at all laps and two staggered raoa 12" sic. in field. Attach
deck to trusses using attachment detail on this sheet
1
»f W pi sLLcco an Lypicm cancreLe
finished stucco bands block construction
REAR ELEVATION
T-__LT.-VATIO>N >IOTr.-S:
Overhangs at I'-O" unless otherwise noted on Roof Plan
Roof pitch at 4:12 unless otherwise noted
Al changes to this plan shall be submitted to the architect
for approval in writing prior to starting construction.
Return ALL Stucco Bands Into Window or Door.
SCALE: 1/4' - 1'-0"
Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #11651.12
2L ga. 5v crimpmetal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(tgpe 2) 30 lb felt underlagment installed with min. 4 side laps and L" and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L sic. at all laps and two staggered rows 12 o.c. in field. Attach
deck to trusses using attachment detal on this sheet
/8" thick x 8"w cut
)ral finished stucco bands
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" CDX Plywood nailed at V ol
in field and edges with IOd ring shank galvanized
.. nails into truss webbing.
12
12 ) ! 4 SLOPE
4 SLOPE
OL'-1' T.O.B.
I
II la° 1a"
'—I" T.O.B.
MOM 0
12" 2,. H.
o ■ 5/8" thick x 8"w cut 5/8" thick x 8% cut .
3 coral finished stucco bands 3 coral finished stucco bands lO.
thick X 8% cut
- coral finished stucco bands
5/8" thick light textured
stucco on typical concrete ®®®
=
8thck lght Finish Columns withFin Floor block construction Jill Garage Finis ed loor
---- -- — — — — — — — ----------------------- ---------------- —O'4" A.F.F. 5/iitextured stucco on typical concrete 5/8" thick cut coral
block construction finished stucco bands
LEFT ELEVATION FRONT ELEVATION
SCALE: II - 1'-0" SCALE: 1/4' - 11
2" x 4" top platerl—l"l 1/2' drywall ceiling on truss bottom cord
base —board
I/2" drywall on
2" x 4" studs at 14" o.c.
2" x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
it #10/10 WWM on L mil Visqueen over
clean compacted termite treated fill
Interior Non -Bearing Partition
Braden it
Braden AIA, PA
Architects - Planners
411
S.E. Coconut Avenue
Tel :
(112) 281-8258
Fax :
(112) 281-8283
E-marl:
bradenaiascomcast.net
nLs
Wdnne Building Corp.
The Grand Carlton
Spanish Lakes
St, Lucie County Florida
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: I Edition and ASCE i-10 for Wind Loading
Building Damon is: Enclosed Risk Catego"rg: II Wind Velocity: ILS mph ultimate
Mean Roof Heights III—O' Rod Pitch:yl2
Internal Pressure Coefficient: to_Ie
Subjectabilitg to damage from: Weathering: Negligible Termites: Vera Hal
Width of Rod End Zone: 3'-4" Wind Speed: mph ultimate
Wind Exposure Clasmfication: C 1.21 x O.L 0.�2L
Adjustment factor for Exposure Height: ASD demon
Load Combination: ASCE i-10 Section 2.4 DL+LL: DL+O.LWL; O.LDL+O.LWL
Components I Cladding Wind Pressure (NET) R Zone: I. +20.L/-124 pal
RZ Zone: 2. +20.i/— 1.0 pot
Rod Zone: 3. +20.L/-84.0 pal
Components I Cladding Wall End Zone Width: 3'_4'
Components I Cladding Wind Pressure (NET) Moons. done: 4. +35.8/-38.1 pd
Wall Zone: 5. +35.8/-41.8 psf
Components I Cladding Wind Pressure (NET) on Garage Door:+32.0/-40.31asf
Shear Wells Considered for Structure? Yes
Continuous Load Path Provided? YYap�ss
Are Components an Cladding DaLaifs Provided? Yes
Minimum Sal Bearing Pressure: 2500 nsi. Presumctive: X $a Test: cm
ROOF LIVE LOAD: 31.— pal ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: —a— list FLOOR DEAD LOAD: psf
JOB ADDRESS:
Date Drawn Reviaf�e�"
GARAGE 3-2L-20
Gll
Drawn b :
LEFT C.C.0 R VIEWED FOR
Checked by: CODE COMPLIANCE
D.R.B. ST. CIE COUN
a ll
[:3 WRoof Zone I
ails Zone 4
Roof Zone 2
Walls Zone 5
END ZONE
RCorner Zones
ad Zone 3
Sheet Comm
�. l2 2�
B
OF 5
I
FLOOR PLAN
,HI
CRASH POST DETAIL
N.T.S.
TYPICAL NOTES: SCALE 1/4" = 1'-0"
1.
Contractor to verif ALL notes and dimensions prior to
p
high by 4"
teel crash poet.
steel
s
diameter
Floor
proceeding with work.
Flange with 4 -
3/8"
2.
Contractor to STRICTLY enforce ALL OSHA Requirements.
expasion bolts
sla n(3/set so
into
kai steel plate)
3.
ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress.
`"
4.
No dissimilar metals to touch.
2%" 2'h"
5.
ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
/2"
%2"
ALL Concrete used for vertical filled cells, Cont. tie beams etc., to
m
6.
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
Orywall at ceilings shall be leveled and attached to bottom chord
<3/a" �°
4'
2';'
2 iA::
of trusses with screws per FBC R102.3.5.
1. ALL wood in contact with concrete shall be pressure treated.
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements. h'
12. Lowest finished floor to be set by Governing Building Department `
surveyor to set in field.
13. Separation between residence and garage shall be per FBC R302.6
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
Water Heater
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1
16. Wall and telling finishes shall have asmoke-developed index of not greater than 450 per FBC R302.9.2
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant I• x L" P.T. Buck
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation block with case hair
materials exposed on the underside of the roof deck or on the attic walls shall comply prior to dear altos[
with F.B.C. R316 - see permit info box of code edition
18. Gyyppsum board material shall conform to ASTM C36, C-19, C415, C514, C630, C931
C960, C1002, C104'1,CIIli, C1118, C12-18, C1395, or C1396 and shall be installed
according to the following: (FBC R102.3.5)
Dr wall
Thickness
Location
Orientation
Framing
Member
Max spacing
of fasteners
Nall ezing options for
installation of drgwell into
Spacing
Maximum
wood framing members
2" x min. thickness
Nails
Screws
Ceiling
Perpendicular
24"
1"
12"
13ga 13/8" long with 19/L4" head
0.098' diameter x 1 1/4" long
annular -ringed or 5d cooler Hall
/2
�R
Walls
Either
IL"
g•
IL"
0.080" di 1 5/8" long with
Direction
15/44" head
OR
Grown board nail 0.084' dia.
x 5/8' with 9/32' head.
Ceiling
Perpendicular
24"
l"
12"
13ga 1 5/8" log with 19/44' head
O
0.098" diameter x 1 3/8" long
annular -ringed or 6d coder marl
Walls
Either
IL"
8•
I6"
0.092" dia. xR 1 1/8" long with
Direction
I/4' head
OR
Ggpsum board nail 0.0915" dia.
x I 1/8" with 19/44" head_
Install SGD thru buck into
block with 3/I4" tap -con with '_-
1 1/2' penetration at L" o.c. max.
from each corner and 20.' o.c. max
thereafter at head per product approval
Use 3/I4" tapconwith
1 1/2' penetration at L" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product a_p ro
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A1311
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR CII18 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -telling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanyln smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supplg and MFG 5v Crimp Metal roormg FL #11651.12
2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min.
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
s aced V o.c. at all laps and two staggered rows 12' o.c. in field. Attach
dpeck to trusses using attachment detail on this sheet
Simpson HETA 20 or ague[
hurricane anchor a each truss 12
with (10) lod x I al nails PRE-ENGINEERED TRUSSES
( 24" o.c.) supporting Maxat 24'o.c. TYPICAL
18101bs. uplift
(h drawln a b manufacturer)
Aluminum Drip s
Edge t Fascia
2" x L" Sub -Fascia
Kagcan full o vent vmgpl aorfit i
using 1/8" din shank x 1.5" long
raring nail" with S/8' die. hoed
product approval - see chart of
5/8' thick light textured
stucco on tgpical concrete
block construction
#5 bar Vert. w/
30" overlap
at each Pilled cell
al
V
Grade
-
� [III„ [III
1
� [III ll, III
a op g g
R-30 blown fiberglass
in bottom chord or trusses
I/2" drgwall with smooth finish
Two rows or beam block filled with concrete
and (U #5 bar cont. in each row. Substitute
precast lintel filled with concrete and (1) #5
bar Cont. for bottom row over openings
1/2" dr wall over I" x furringg
strips a� IL" o.c. with R4.1 ri-roil
insulation on tgpical 8" Block walls
All drgwall to be installed per FBC R102.3.1
T and shall meet all pertaining ASTM codes.
ao Mortar to be Tgpe "M" onlgg proportiored per FBC RLOIJ
and Mortar Jonts shall compwith FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex showers, tubs etc...>
FIII cell with concrete and
() #5 bar Vert. (tgpical).
Max apaeing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
VxV #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
II �
14 w x 18 Concrete footing
nth (2) #5 bars cont. and #5
transverse bars at 48" o.c.
TYPICAL SECTION
Scale : 1/2" = I'-O"
led to Masonry Beam
led nails
in
Head
fixed door
sliding door
AREA
CALCULATIONS
Living A/C
= 1444 sq.
ft.
Front Porch
= 141 sq.
ft.
Rear Porch
= 200 sq.
ft.
Garage
= 321 sq.
ft.
Total Under Roof= 2108 sq. ft.
Total Cubic Ft = 11,548
2' VTR
I"
2
.. 12„ I
I BAATF
r
LAV-I 211
I"
2"
we-i "
2" LAUNDRY 2" 3" 2" s' AAv s' VTR
3" aT-1
KTICHEN 2"
2
2" LAV-II
3"
3" we -I BATH 82
"
211
3• a -I
FLUMBiNG RISERcc
To Septic
I" x L" P.T. Buck nailed to I O
block with case hardened nails
prior to door attachment
n Masonry Wall = :;t L-
el il
I I/2"
Bottom Track Typical Flooring
Sill Install SGD thru buck into
block with 3/16" tap --con with
Sliding D oor Detail I penetration at Vx.
fromom each corner and 20.."" o.c.. max
thereafter at Jambs per product approval Jamb
At Masonry Wall NTS
Window Schedule
Mark
Size
Rou h O en.
Window Descri tion
PRESSURE ZONE
I.
4'-5k"x 5'-3�a"
54ka"x 1.3W,
Single Hung
ZONE 4
2,
V-2%a"x 5'-3 %"
75" x 103 %;'
Single Hung
ZONE 4
3.
'-2' x '-2 I/2"
21 /,"x 38 `%a°
Single Hung
ZONE 4
4.
4'-Sia"x 4'-2'/a" I
54!a"x 54Ye"
Single Hung
ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit info box on sheet I
ALL Windows in bathrooms to be tempered
All rough opening dimensions to be verified bg contractor
with manufacturers specs prior to construction
Door Schedule
Mark
Size
Rou h O enln
Door Descri Lion
PRESSURE ZONE
A
9'-0" X 7'-O'
108" x 84'
Overhead Garage Door
ZONE 4
B
3'-0" X 6'-8'
41%"x 83%"
Fiberglass Panel - [naming
ZONE 4
C
L'-O" X L'-8'
't4" x 81/," m;;t°"
Sliding Glass Door
ZONE 4
D
2'-O' X 6'-8'
Solid Core - Wood - L-Panel -Bi-Fold Finished
24' x 81 %;'
E
2'-4" X L'-e'
Solid Core - Wood - L-Panel
F
5'-O" X 6'-8"
Solid Core - Wood - 6-Panel - Bi-Fold
G
2'-8" x V-8" x 1 %,`
Solid Core Wood, Steel, or Masonite Door
H
2'-e" X L'-e"
Solid Core - Wood - I. -Panel
J
2'-6" X 6'-8"
Solid Core - Wood - L-Panel - Bi-Fold
K
2'-8' X L'-8'
Solid Core - Wood - L-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet #1
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41
All rough opening dimensions to be verified bg contractor
with manufacturers specs prior to construction
in
I
N
4'-0" 9'-6" 12 8'-C 12"
OPTIONAL
Q PATIO/SLAB
[fliEl I UlLjII �o o Oo 0 0 0
° EGRESS
IT -a"
°
MASTER
BEDROOM
U=
mar6
8'-0" A.F.F.
Flat Ceding
11 N
0
N
Drger
1 wall
o AiC
Meter
O
t O
Rod 4`15helf
6'-0"
6'
4"
"
Vanity to
a i" I
4 y�„hig
tr°n
�- 1
CLO E I g
"
i
2"
ac bs
rr
1
enm
I
Rod t Shelf J 8::
�ID 4
ATH0
I o
KITCHEN
I
L--(
it SA.F.F.
o
Flat Ceiling
6'
Upper cabinets to
ext rid over Rol.
12" x 12" Concrete column /
block filled with concrete and
(2) #1 bars Vert. tied Into
lintels above
Covered Porch
8'-0" tol9'-8" A.F.F.
Vaulteld Ceding
GR IAT
ROOM
I
I
19'-8" 1
I
I
�r
I lY
x V knee -wall B' O" to 9'-8" A.F.F.
xu counter top 1 Vaulted Ceding
DINING
ROOM
I
♦♦ I Vanity to be
34 ?2 "high
QN, a.
R-II meta Indati n
4 W.H
Steel Bellerd. I
4
Sas detail aA fbia-sheq]` '
22x 64'A
Provide auto I A ash O I
closer
L----- 22" _y
150 Amp a 4" ,_af
Panel
ai E RGEN Y
GARAGE EGRES
O '-4" A.F.F. 00 MT
O Flat Ceding r
N
r----------------- I
I Block wall in
i-� garage to be
1 struck block I
I I
I
I
L9'_OI, I
161-101,
Install windows thru buck into
block with 3/I6" tap -con with
I 1/2" penetration at V o.c. max
Prom each corner and 20." o.c. max
thereafter at iambs and 20' o.c. max
Exterior face at head and all per product approval
of wall Buck to be i' x 4' PT
1 E BATH
Rod t SheIP
A.F.F.
IV Flat Ceding
SECOND rq
w
BEDROOM
0-
-EGRESS
NUN 1111
T
0
COVERED
12' x 12" concrete
0 R C with con rote and (2)
Into lintels
6' 2" II'-6"
2'-e"
5 -4
Its
3'-ry
block filled
•s Vert. tie p
6" �a
4'-2"
3'-4"
Attach buck to block wall with
1/4" dia. Eleo cone screws with min.
11/4" penetration at 12" o.c. max
and 4' max from each corner thru
Exterior face 2' x L" PT Buck
of wall
ones
N
I x4 P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
88 Wood screws thru iamb into buck
Windows
lock with case hardened nails ON ALL JAMB, HEADER, AND at each hinge and 15' ale. max and
Detail a t l U i n d OW S prior to window attachment SILL BLOCK PRIOR TO BUCK DetaII a t ®OOr prior to door attachment
INSTALLATION
NTS NTS
m
Braden t Braden AIA, PA
Wes( nne Building Corp.
Date Drawn Revisions :
Sheet
Architects - Planners
411 S.E. Coconut Avenue
The Grand Carlton
GARAGE
LEFT
20
3- win bg:
Drawn by: REVIEWED FOR
2
Tel (112) 281-8258
G.G.U. CODE COMPLiANO
Spanish Lakes
Fax (112) 281-8283
Checked by: ST. LUCIE COUNT
E-mail: bradenaiascomcast.net
Siusirt Pl 'A4ggL nAAr�nnnnao
St. Lucie County Florida
D.R.B. ROCC
OF 5
Comm it
12-2,
B
17r%U`. I UllL- INk,/ I =J:
I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXiST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
3. POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5. LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
COMPACT EACH LiFT TO AT LEAST 95% OF ITS MODIFIED DRY
PROCTOR VALUE.
6- GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
T• GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
FOLACIATiON FLAN
8. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (iF PROVIDED) PER PLANS
9. DESIGN LOADS ARE AS FOLLOWS:
ROOF IDL+LL) = 41 PSF
WiND VELOCITY = PER PERMIT INFO BOX ON SHEET #1
EXPOSURE ="C"
10. ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-I6, t
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 30-7 STEEL.
11. ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
12. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
13. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
14. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
IS. ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN FINE, UNLESS NOTED OTHERWISE.
16. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
4. Verify all recess thickness at showers, tile, etc....
5. Contractor to provide filled cell with concrete and 1 45 bar vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings up to 5'-11" Wide.
and Provide (3) filled cells on each side of openings from 10'—O" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c. unless otherwise noted (see section)
b. Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade LO, meeting ASTM A —I(. and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar vert. w/
30" overlap Fill cell with concrete and
(l) #5 bar vert. (topical). Thicken edge to 8 x8"
SCALE: 1/4" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
at each filled c Max. apacing shall not exceed with concrete and 4" concrete slab with frbermesh OR
goad 48" unless otherwise noted one #5 bar continuous L"xG" #10/10 WWM on 10 mil Visqueen over
see foundation plan notes for clean compacted termite treated fill
sae spacing at openings
4" concrete slab with frbermesh OR GRADE
60xL" #10/10 WWM on L mil vrsqueen over
clean compacted termite treated fill °D — —
Grade ?a
r -
14 w x 18 d Concrete tooting
gg
with (2) #5 bars cont. and #6
transverse bars at 48" o.c.
F I ) TYPICAL FOOTING DETAIL
_ SCALE 1/2" = 1'-O"
4" concrete slab with fibermesh OR
6"xV 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cont.
Step per
foundation plan
\j— _J DETAIL AT
12" x 12' concrete column
block filled With concrete
and (2) #1 bars vert. tied
into lintels above
Top of fcater
iL" below finished floor
#5 bars cunt. bottom steel
ARAGE STEPDOWN
S,C`bLF 1/2" = V-
-_I
`30"x30"xl6" concrete
column footing with (4)
45 bars each way
DETAIL
Wolto
#5 bar cunt. in curb,
Curb height
Verrfo based on
foundation plan-
Is
n
O Contractor to provide
v0 proper foundation chairs
for proper steel installation
N
SLAB EDGE DETAIL 30" min.
SCALE 1/2" = 1'-0"
#5 bar vert. w/
30" overlap Corner Steel Lap
�at each filled cell
Fill cell with concrete and
(l) #5 bar vert. (topical).
Max. spacing shall not exceed
Wood 48" unless otherwise noted
Base see foundation plan notes for
/ spacing at openings
4" concrete slab with frbermesh OR
VxL" #10/10 WWM on L mil Visqueen ova
,/ clean compacted termite treated fill
2" x V PT wood secured with
1/2"dia. x L" expansion anchors
with 2" sq. washer at 18" o.c. overhead door track secured to wood
jamb per manufacturer's product approval
Gara(4e Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS
iN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
nits
Filled Cell Masonry Column With One
45 From Footing To Tie Beam
Conic. Fill To Be 3000 PSI
See Floor Plan For Location
r
I de-
i° vo
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
#5 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden it Braden AiA, PA
Architects - Planners
r411 S.E. Coconut Avenue
MB Tel : (112) 281-8258
Fax : (112) 281-8283
!=-mail: bradenaiascomcast.net
1 14'-0" 1' 41 h' 1 20'-0" 1
r---------
°
F z°
J
— F
J
�L—
®L_
81
O
Filled cell under
girder above
I
I
24"
i
I
I
Rear Patio/Slab
O
r J
to
be poured separate
from the house slab.
u1
®I
I
o
I
Thicken footing to
24"w x 14"d x 24"L
I
I
FI under Pilled cell I n
under girder bearing. ° Q FIR] Q °
L--- —\ —-----FI-- — — — -
I
a I Rear Patio/slab to
u 0 c be flush with bottom of
Waa� I sliding door race**.
slope 1/2 I
I
°I I
I I
I I
I
I FI
l
H.B. I I
I 4" concrete slab with fiber ash OR I
Cx6" 1110/10 WWM on 6 mil V squeen over
clean compacted termite tr ated fill
o I
I
°I
i /\i FI I
I °
I m I
I
°
4o I o
I� �
.,
1
o A/C ° r—--------w.H I
#1 I 4'0 Steel Ballard F1 I
r m filled w/ Concrete0
Fif
5
° I 4
to;I IFQIaI I
I ms
I Ems; I I I
I `E4L- I I I
I 3vJu = I L__�a4111 I I
° I a`' N I oo
I _ is -a
N _; I °�.� I.IJ I °
Q-
E O \
V O go - ° -TAT-T-T-T-T-
I/\ . i$ " I -� e I I i I i i °
tF�S(J ` - u w
It,
X I
°
(L
O
® I
L—---------�
°
F
° 1.5" Recess for ° ° °
°° ----
— — — °
° °
°
---
arage Moor
J®
©
3'-5" 9'-O" 3'-5"
6'-2"
II'-6"
6'
12" x 12" concrete
column block Pdle
with concrete
qnd 12)
#1 bars vert. tr
into lintels
above
Wynne Building Corp.
Spanish Lakes
St. Lucie County Florida
FOOTING
SCHEDULE
Mark
Sire
ofecriPtion
I
14"W
x 18"D
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH
(2) U5 BARS CONTINUOUS
30"
x 30" x IL"D
COLUMN FOOTING WITH (4)
#5 BARS EACH WAY
F
e"W
x 8"D
THICKEN SLAB EDGE
WITH
1 #5 BAR CONTINUOUS
F5
14"W
With
x 18"D
Curb at Garage
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS - CURB a 0'-O"
Date Drawn Revisions
G3-25-20
GARAGE
LEFT Drawn bg:
C.C.U.
Checked bg:
D.R.B.
Sheet Comm #
12-2b
3. B
OF 5
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = 8d ring shank (min. IS" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plgwood
4. Use nails or screws bas d on ress re for roof stated
in permit info box on t�ese pans for zone 3
Ke
Area
Ede
Field
Fastener
Max.
Pressure
Zone I
Ifof8d
ring shank
45 psf
Zone 2
6"
8d ring shank
16 par
Zone 3
"
8d ring shank
84 psf
** Zone 3a
(v
6"
#8 wood screw
112.5 psf
** Use nails or s rewe based on res ure for r of stated
in permit info �ox on these plgns i or zone
Concrete
/ Lintel
Column
Verify With Plan
12"x 12'
1 Column Block
Reber
Reber 4s Bar Dla.
Min. Overlap
to Llntll Attachment
Provide #5 bars with min. 48 bar
diameters overlap into beam. Tie
filled cell steal into continuous
beam block steel. t,_
Provide Cast -Crete =_ -r
8U8-OB/OT precast --- -=
lintel set in mortar _
Min. 8' Bearing---
Provide #5 bar set in pre -cast
lintel into beam where length of
the opening calls for it.
ovide PT Buck
:ached per jamb
ails into filled at
4" Pro -cast
Bill it
Y _-
Filled Call
Provide #5 bars with min. 48 bar
fiameters overlap in filled call. Tie
Pilled call steel into continuous
rooter steel.
R-II batty
Trusses at 24' o.c.
we shop dramings�
by others
R-30 Batts
batts
Kim 4 "'Frame ceding transition
as needed using metal studs
1-4 rheld verfli exact configuration
and sizes
Drywall tailing
sea typical section
Ceiling transition Insulation Detail
nts
:: �; .. ' .. r ,. •. Concrete Footing
`L fees tooter x Ulf
for exact axes)
DETAIL AT WINDOW OPENING IN
CBS WALL Scale: 1/2" = I"-0" Poured Co,
concrete
SINGLE PLY REAR GIRDER TRUSS
Nol 2' x 4' bloelung to vei't. leg of
truss with IOd x 1.5 nails at 4' oc.
'v Install Simpson MGT into mall win
n 5/8" dia. threaded rod tern. 120
\HY/" into net beam and (22) lead nails into trues
TRUSS BLOCKING DETAIL Poured Concrete
AT GIRDER STRAPPING concrete block
AT CENTER BEARING POINT nor facture
NTS n
1/8" thick light textured stucco installed per
ASTM C 924 over ASTM D tgpe 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Tgpe 2 felt paper using 8d nails. Substrate
to be 19/3Z' CDX Plgwood nailed at L" o.c. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
2L ga. 5v crimp metal roaring attached to plywood clack using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over A5TM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and V end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced V o.c. at all laps and two staggered rows 12' o.c. in field. Attach
deck to trusses using attachment detail on this *beet
LINTEL SCHEDULE
Mark
flint ex
Lintel
Castdeaitwn
8
Rates of
• A� ock
Bottom
Stool
saw
Tarp
Stead
�
max
oad
(PLF)
Ha
Loud
MLP)
max
Load
fPLP)
L22
2'-2"
3'-L'
GPO-®B/IT
1
85
3061
591
1024
LSI
; IL
4'-O•
OP8-05/IT
1
=6
2MI
IU3
163
L45
V-V
5'-10"
61"111 IT
1
a5
111
104
331
LBO
6'-0"
V-V
BF8-OB/IT
1
#6
We
936
121
LLO
L'-8'
11-L'
spa-OB/IT
I
a5
loll
121
934
L80
9'-O'
II
011`8-IB/2T
1
*5
2
95
152
591
612
L10
1'-O'
MY-L"
SPa-I8/2T
1
85
2
86
L43
530
401
LaI
11
10r-4'
BPIL-I5/2T
ONE
1
$5
2
85
533
nos
401
LIOO
IO'-Ow
I W-4'
OP9-I5/2T
1
s5
2
a5
592
444
452
LIOOB
10'-O'
W-4'
aPht-I8/2T
ONE
I
s5
2
$5
11144
1020
452
L120
IW-O'
W-4'
1111118-IB/2T
1
#5
2
a5
411
1 428
324
LI20B
17-0'
IS'-4'
SPIL-I8/2T
ONE
1
s5
2
a5
WIS
110
324
LMO
W-O'
W-4'
aPIL-19/2T
ONE
1
#5
2
86
11250
601
2541
LW
IC-O'
M'-40
SPs-18/2T
1
s6
2
96
Soo
M2
194
LII
W-Om
11'-4' I
SPIL-I8/2T
ONE
1
85
2
s6
150
500 1
144
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION. HANDLING INFORMATION. AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2' nails -
( 24' o.c.) suppporting Max.
18101ba. uplift
Aluminum Drip �"
Edge t Fascia
a"
2" x V Sub -Paste
Kalican full o vent vinyl soffit installed
wing 1/0' dia ahank x IS' long gels.
roofing nails with 3/8' dia. head per
product approval —see chart sheet #1
12' x 12" concrete column
block filled with concrete
and (2) #1 bars vart. tie
into lintels above
thicken edge to II
with concrete and
one #5 bar continuous
BEYOND
Top of tooter
16' below finished Floor
12
4
Aluminum Drip
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable and truss
With (2) IOd " �i,ls�
at each web
hI lath
vertical wood
a to provide
ration nRo
3/4' penetration
wembers
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#5 bar vert. w/
30' overlap
at each fulled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Step per foundation plan
C3 Slope per foundation plan m
I
Uummum Panel
lees per manufacturer
See Tunica) Stud Detad
1/8" x 3/32' Wing Nut w/
appropnata r's we and spacing
per manufactureDetails
.Stud Detail
Stud w/ Die Cast Zinc NTe
Nickel Plated Wing Nut
Flush Mounted Shutter Detail
nts
Brace Gable and
with 2" x 4' SYP #2
aft back nailed to bottom
of top chords using (2) IOd
nails at each truss
IRE -ENGINEERED WOOD TRUSSES
e 24'o.c. TYPICAL
( shop drawings bg manufacturer )
�
rr
X
�
Qu
N
H1oUJ
a
70
a
a ad
ti
SO
A
°°
cn
V-
U
(y
a
I
Brace Gable and
with 2" x 4" SYP #2 min.
eft back nailed to bottoms
of top chords using (2) IOd
nails at each truss
R-30 blown fiberglass
a
z
=
w
O
tr
,Q
in bottom chord of trusses
d o
fa
I/2" drywall with smooth finish
ZO o
W
Two rows of beam block filled with concrete
end (1) #5 bar cont. in each row. Substitute
lintel filled with concrete and (1) #5
grecast
ar cont. for bottom row over openings
1/2" drywall over I' x furring
Pli-foil
to
strips at 14" o.c. with R4.1
insulation on typical 8' Block walls
All drywall to be installed per FBC R102.3.1
i
and shall meet all pertaining ASTM codes.
do
Mortar to be Tgpe "M" only proportioned Der FBC R601.1
Mortar
and joints shall comply with FBC R401.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Strap truss to wall
using Simpson MGT with
Simpson
HETA 20
5/8 dia.
threaded
rod with min 12' embedment
hurricane anchor
at each truss
into beam
(22) IOd
either wet set or In epoxy with
nails into truss. Add blocking to
( 2�" o.c.)
supporting Max.
pp 9
truss leg
per detail
on this sheet
ETA 2® 1810
lbs. uplift
'I
L
WIN
Jou
WA
ru
V5
NAW"Er"'A
I
I
A
FA
016.
WNWA VAEA
i
I
M�WA WMA
I
I
I
M1001 W-0— CEIRA WWMA,
Niiwo
M
LV
all
11�����Wffnd
PVI
MFO Sy Crmip Metal rod,na FL 1111111.12
W WI
screws
ft 2) 30 lb fat
lagpot
2.
SLOPE
ve!lg* 0A
i
lwaai
.�I�ICI�I�IMI��I�I�I�I�I�I
Fill cell with concrete and ROOF FLAN
(U #5 bar wart. (typical).. " ppng shall not owise noeexceed
48unlesstherr
Wood see ng at openings plan note* for
Sass spacing at — OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
J/ 4' concrete slab with fibermesh OR — ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET
L"xb' #10/10 WWM on L mil Visqueen over — TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
clean compacted termite treated fill — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
Tt4wcal Section at Front Forcl-
N
W
C4
W
a
=x
e- to
�r_
IQC
N43
� 1° nL
n
r ` yo 'a ui
ti
in as 00
CL
E OD
ra
tT), 10 'r
v- N
s
cv
W
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
— CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
-2-19
PANEL
"A"
Palo
BR
Lead
Ulm
Descnptam
cwc#
amiss
Dowipten
Wire
Lead
BR
Pelee
1
20
1.2 ka
$12
Rernprstor
I
Raise
#L
12.0 ks
50
2
1
20
1.2 Its
#12
Cloths Washer
3
1
20
IS ks
*12
Kitchen S.A.C.
6
A
D
810
5.0 Its
30
2
1
20
1.5 ke
un
Kitchen S.A.C.
I
8
1
20
#12
Bathreem Recepts
9
10
Arc Condepoor
#10
6.0 km
30
2
-
1
20
1.2 kg
#12
Dishwasher
II
12
I
20
L2 ku
#12
Miaosave
13
14
Arc 14wda
810
6.0 Its
30
2
1
16
-
#14
General LightLng
I6
IL
I
16
#14
Gonerd Lnghtmg
11
18
WH
$10
6.0 kw
25
2
-
1
15
-
$14
Gaiwd Lighting
19
20
I
16
814
Genwrd Lighting
21
22
Goo
812
0.91 KW
20
1
-
I
16
#H
Genial Lighting
23
24
Spam
swo
J 26
1 24
1 Spam
Spare
21
2S
Spam
so"
211
3o
Spam
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting (3, walla wig: lt:).........................
, $mall. Appliance. Circuit(ta ........... . . . . . . . . . . . .......
,Range .......... ......... ........................... ...
Rahlopfptor..................................................
Microwave
Dish Washer
.................................................................
Clothes.Wasllar...............................................
Clothes ,Dryer ................................................
Water, Heater .................................................
garage. Door.Opener.................... ...,...... _.,.....
1135
3
saos
2
1,500
3 000
1
12,000
12,000
1
1,200
1,200
1
1.500
1.500
1
12-0-0-1200
I
I 00
I 00
1
5 000
5 000
1
4.500
4$00
1
810
810
Total Watts
I 35.LIS
First 10000 Watts e100%
1
101000
10,000
Remainder 2SA1S e40%
1
0
10.246
Electric Heat or A/C 10.000 e45%
1
10,000
10.000
Calculated Load
Watts
30.24116
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 12L.02
Panel Size Required = 150 Amps
Electrical S mbol Legend
S
Single Pole Satoh
®
Recessed Can Light
Daiwa Pala Batch
9
EV@W Recessed
e
Push Button Switch
0'
Exhaust Fan
D Outlet
Coding Masted Light
Special Receptacle
♦
wan Mounted Light
ground failift circuit
Light with Pull Chan (attic)
®
Floor Duplex Outlet
Computer Connection Jack
®
Carbon Manaode Detector
4&
Flood Light
Q
Thermostat
m
Electrical Panel
+�
Central Vac
8
Electrical Meter
Q8
Smoke Detector
Ceiling Pan
®
Television Jack
©
Telephone Jack
Ac oisc
A/C Disconnect
I x 4 Florescent Light
®
2 x 4 Florescent Light
®I
Speaker Hook -Up
= JUNCTION BOX TO SUPPORT A PAN
O = THERMOSTAT LOCATION
B/A = BALANCED AiR
10 CFM
IOpdOxt
MASTER
BEDROOM
143 CFM
IOxlOxi
12x12x9
B/A
LN
B/A
CLOSE
Kent-thu_
Soffit *109A7H
i FIELD VERIFY SERVICE LOCATION RESPECIVE TO PANEL LOCATION AND USE APPROPRIATE RISER BELOW
#2/0 AL SER Cable
(3) #1 THHN Copper
With #1 Grnd --------
2" PVC Schedule
40 conduit
2" PVC Schedule
ISO
40 conduit sleeve
IS
into attic
MCB
PANEL AHU
PANEL ,
200c rated
meter can
200a rated
meter can
ME
ME ER
Intersystem bonding
ME ER
Intersystem bonding
2" PVC ( FPL Termination pant
2" PVC ( FPL
Termination pant
schedule 80
schedule 80
2' riad service FPL
2" naid service FPL
I� ground rada---___ ( I ground rods ---- ---
ELECTRICAL Ri+SER ALTERNATE SERVICE ELECT. RISER
- Contractor shall use AL-CU Landing lugs. NTs - Contractor shall use AL-CU Landing lugs. NTs
- Contractor shall torque lugs I.A.W. - Contractor shall torque lugs I.A.W.
manufacturers recommendations which manufacturers recommendations which
shall be verified prior to construction shall be verified prior to construction
- Verify AIC/KIC Rating prior to ordering equipment - Verify AIC/KIC Rating prior to ordering equipment
ELECTRIC NOTES:
OPTIONAL
PATIO/SLAB
- °
I °
o^
PATIO/5LAB
I
CAR AT
RO M _
I c
I
Irears
I9 Con coding �149 CFM
I0( I IOx1Ox1 -
1200
L - - - - - - r- -
I_T
�`
I
r
R
nx o
I 4%
A/C
w.H. I
1
#1
- 17" I F_�I
I Ash& II =GI
I
j
I
L-----J IQ
I
150 Ampr-
Meterril
hPanel ff
GARAGE
r----------------- i
I I
I I
I I
I I
I I
I I
I I
I I
1 I
1
1 I
1
DINING
ROOM
ATH�
232 CFM
12xLx1
\ SECOND
1 BEDROOM
1 1 12x12x8
"N B/A
COVERED
PORCH
MECHANICAL LAYOUT
SCALE: 114" = 1'-0"
I.
Use copper wire onlg Prom panai to devices
15.
Contractor shall guarantee all materials and workmanship
free defects a less than two from
20.
All equipment and panel sizes shall be verified before
The
2.
Provide and wire all required smoke t Carbon
of or period of not years
ordering. contractor shall provide circuit routings to
Monoxide detectors.
the date of acceptance or certificate of occupancy, or one
suit the job conditions.
3.
Contractor to verify location of electrical
year from closing sale of house.
service and provider.
Correction of defects shall be completed without additional
21.
Furnish and install all fixtures as called for on the plans
4.
ALL bath and kitchen receptacles to be GFCI Protected.
charge and shall include replacements or repair of any
or as selected by others.
S.
ALL exterior outlets to be WP/GFCI protected.
other phase of installation that may have been damaged.
A.
Recessed cans to be installed per NFPA requirements.
IL.
It is not the intent of these plans to show every minor detail
22•
All raceways and pipes placed in or through any concrete
1.
Tamper resistant AFCI receptacles are required in
of construction. The contractor shall Furnish and install
slab shall be spaced a minimum of three diameters or the
ALL rooms.
all items for a complete electrical system and provide all
largest conduit or pipe from any other service.
S.
A/C Return Air Balance Must comply w/ FBC RMI1.02
the requirements necessary for the equipment to be placed in
9.
(C R fri lit lines that are run thru slabs must be
�G
proper working order.
23.
All exposed wire below 9'-1' shall be installed in metal EMT
10,
sTeevedaIn
ALL A/C Equipment shall comply with onargg calculation
11.
All work shall be done in accordance with the N.E.C. and
local
conduit.
Braden It
Braden AIAe PA
II.
All work shall be by a licensed electrical
shall comply with all codes and ordinances, and shall
the local
24.
Dryer Vents to be installed per
performed
the be fully
most all standard requirements of electric utility
FByC RMI502
Architects
- Planners
12.
eontraetor, completed system shall operative.
Contractor for
and telephone company.
shall pay all Tees, permits, testing, and
blower
411
S.E. Coconut Avenue
13.
inspections including testis where required.
All work shall be coordinated with trades to
18.
The electrical system shall be completely and effective)
: (112) 281-8258
other avoid
grounded as required bg the latest edition of the N.M.C.el
interference with the progress of construction.
Fax
: (112) 281-8283
14.
All required insurance shell be provided for protection
19.
All material shall be new and shall bear underwriters'
E-mail:
bradenaia comcast.net
against the publrc liability and property damage for the
labels where applicable.
w. r,
w iww. .� e ♦ �wwwwww
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
WP GIN
Install owlet
under disc. w
H B not shown or Q
clarity
Vent thru a
o�`fit F
iC
Meter
OPTIONAL
PATIO/SLAB
s
,'Covered flora,%,
MASTER EP
BEDROOM WP GFCI
\\
\ -5 I v
_ - - Smoke / Carbon G R EAT
i
Monoxide Detector R O M
/ Combo
S I
C
I
GFCI _ I
-' - I
CLOSE © I
I II
GFCI I I I
-m --J
---� GFCI I I NING
ROOM
1 Fc `
GFCI GF I/ \ I \\ I I k
F
9 1 KITCHLN-------I S�
I
/�4„ l 3,_2„ 3,_2" Nines F
/ C.M. Detector
I per FBC
R3'�4.3
Ill 111 r.rr� rn rani
GF C
42" GFCI
w.H.
A t W J
` L
150 AmR FOpticn:
Panel Pull aliens panel location
light in attic
42" GFCI
GARAGE
II Garage
Door
Opener
r----------------- i
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
i
ELECTRiCAL PLAN
Ilul O Cente ! \� ®� Nor
Bf-DROOM
Total Attic Space = 2124 sq. ft.
Venting Ratio 1/150 = 14.16 sq. ft. required
Provide A Continuous Vented Soffit
Ill nne Building Corp.
Spanish Lakes
St. Lucie County Florida
/
WP
\ � � COVERsir:r
f-1 `P'-CRCH
SCALE: 1/4" = 1'-0"
Post Light with � `o
Photo tall 1 C N
Date Drawn Revisions
G3-25-20
GARAGE
LEFT Drawn bg:
G.C.U.
Checked by:
D.R.B.
G'-31,
O
iv
H.B.
Exhaust Duct
^Thru Soffit
Wire For
Front Post
Light
Sheet
F. -
,�b,rta�
OF 5
Comm #
12-2�