HomeMy WebLinkAboutFloor PlanREMODELING, ADDITION, ALTERATION, AND GENERAL NOTES CONSTRUCTION TO FOLLOW 2011 6TH EDITION FLORIDA BUILDING: CODE 4 ALL AMENDMENTS 1. Contractor to verify all dimensions prior 5. Do not scale drawings, if there are written S. No egress from a bedroom or sleeping area to the commencement of construction. dimensions to take precedence. Dimensions has been compromised by this enclosure. 2. Determine the existence of arty underground and construction details may vary due to tanks, drain fields, wiring, plumbing, piping, etc, substitution, field conditions, construction and allow for same during construction, technique or other variables. 3. Verify adequacy of existing electrical service 6. These drawinggs are not intended to cover all and wiring capacity. Upgrade and sub -panel as conditions. Field decisions may need to be NOTICE - required Relocate any tv, phone cable, made by Contractor. If this situation arises, please It is important that the Client and Contractor examine the thermostat, fans, chimes, outlets, switches, contact Engineer of Record, drawings and documentation in detail. It shall be the final smoke detectors, fixtures, etc. as may be Contractor shall allow for minor adjustments, responsiblllty of the Contractor to review and double check required. -1. Certain assumptions have been made using the the plane for accuracy and compliance with regulatory agencies. It is customar 4. All wood members exposed to weather or in beat judgement and experience of the design a g y and ordinary not to include details contact Concrete and/or masonry shall be team. No demolition has been undertaken by well within the knowledge of licensed Contractor. If pressure treated, the designer to verify the conditions and necessary, further clarification of these plans should be achieved before Signing the construction contract and construction techniques employed in the obtainingg a buildinggpermit, otherwise the Contractor assumes existing structure. The contractor shall verify reeponsiblllty for the construction in question. Methods of actual conditions prior to undertaking construction shall be determined by the Contractor. GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE & SHALL CONFORM WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES. 2. FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS, DENS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS TO HAVE ARC FAULT PROTECTION PER 2014 NEC SECTION 210.12 (B) 3. ALL 15 & 20 AMP RECEPTACLES IN KITCHENS, FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS TO BE OF THE TAMPER RESISTANT TYPE PROTECTION PER 2014 NEC SECTION 406.11 4. GFI OUTLETS ARE TO BE INSTALLED IN THE KITCHEN, BATHROOM, GARAGE, & OUTSIDE LOCATIONS AS NOTED (GR ON PLANS. 5. FINAL PLACEMENT OF ALL ELECTRICAL COMPONENTS TO BE DETERMINED BY THE ELECTRICIAN OF RECORD IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE & SHALL. CONFORM WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES. 6. ENGINEER OF RECORD NOT RESPONSIBLE FOR ELECTRICAL PLANS ALL fi'LUME31NCx, ELECTRICAL, 4 AG WORK TO FOLLOW THE RESPECTIVE CSC 2011 6TH EDITION CODES FOR EAG>}-I TRADE 'ALTERATION =LEVEL II SCOPE OF PROJECT THlS PROJECT /5 FOR ,4N INTERIOR RENOVATION OF THE EXISTING BEDROOM FOR ,4 NEW 43-47'14ROOM .441— ,4RE,45 OF WORK TO BE FlNl51-LED TO M.4TCN EXJSTING ALL. WORK l5 TO BE DONE PER THE FBC 2017 6714 EDITION PER THESE P/-,4N5. DEFACED / DEL4MINATED CONCREi'E REPAIR 1. REMOVE DELAMINATED OR OTHERWISE UNSOUND CONCRETE, FROM AREA TO BE PATCHED, $AW CUT AS NECESSARY TO PREPARE AFFECTED AREA. 2, DO NOT CUT REINFORCING STEEL, IF REINFORCING STEEL IS REVEALED EL£CTRIGAL REMOVAL SHALL CONTINUE UNTIL 4" OF REINFORCING STEEL IS REVEALED. 3. REMOVE CONCRETE AROUND REINFORCING STEEL APPROX, 1" AROUND EXHAUST FAN LIGHT RELOCATE EXISTING f'LLLME31NCs a ELECTRICAL TO NEW LOCATION � .FOR THE BATHROOM oNLY NEu/ ELECTR/CA,L lS aN0/UN ,4UD/T/ON.dL ELEGTR/GAL MAY BE ADDED A8 NEEDED PER FBG GODS BY THE ELGTR/G/AN OF RECORDNEW _p _ � r iY1 n , , I1111 �\ II¢II EXISTING / II II W OW TYPICAL 2x4 WALL: N BF 1/2" DRYWALL TAPED < SANDED (DUROCK FOR WET AREAS) INTERIOR 2x4 STUDS * 16" o.c. NON BEARING WALLS 1/2° DRYWALL TAPED < SANDED. PAINTED TO MATC �^���� EXISTING O , INTERIOR WALLS EXISTING A�� 't C88 WALLS t0 REMAIN TO REMAIN DASHED / REVIEWED FQh rA EXISTING BEDROOM'.. /121-011 EXISTING NEW 5ATHROOM RENOVATION FLOOR PLAN SCALE, I/4' . I'-0" CODE COMPLIANt' ST. L.I.nCIE CC?U­`°' Copyright 2020 ROBERSON DESIGN GROUT' All rights reserved. REVISION DATE JOB " 2091 DATE : 8/6/20 PRAWN BY SR SHEET 1 Of 1