HomeMy WebLinkAboutFloor PlanREMODELING, ADDITION, ALTERATION, AND GENERAL NOTES
CONSTRUCTION TO FOLLOW 2011 6TH EDITION FLORIDA BUILDING: CODE 4 ALL AMENDMENTS
1. Contractor to verify all dimensions prior 5. Do not scale drawings, if there are written S. No egress from a bedroom or sleeping area
to the commencement of construction. dimensions to take precedence. Dimensions has been compromised by this enclosure.
2. Determine the existence of arty underground and construction details may vary due to
tanks, drain fields, wiring, plumbing, piping, etc, substitution, field conditions, construction
and allow for same during construction, technique or other variables.
3. Verify adequacy of existing electrical service 6. These drawinggs are not intended to cover all
and wiring capacity. Upgrade and sub -panel as conditions. Field decisions may need to be NOTICE -
required Relocate any tv, phone cable, made by Contractor. If this situation arises, please It is important that the Client and Contractor examine the
thermostat, fans, chimes, outlets, switches, contact Engineer of Record, drawings and documentation in detail. It shall be the final
smoke detectors, fixtures, etc. as may be Contractor shall allow for minor adjustments, responsiblllty of the Contractor to review and double check
required. -1. Certain assumptions have been made using the the plane for accuracy and compliance with regulatory
agencies. It is customar
4. All wood members exposed to weather or in beat judgement and experience of the design a g y and ordinary not to include details
contact Concrete and/or masonry shall be team. No demolition has been undertaken by well within the knowledge of licensed Contractor. If
pressure treated, the designer to verify the conditions and necessary, further clarification of these plans should be
achieved before Signing the construction contract and
construction techniques employed in the obtainingg a buildinggpermit, otherwise the Contractor assumes
existing structure. The contractor shall verify reeponsiblllty for the construction in question. Methods of
actual conditions prior to undertaking construction shall be determined by the Contractor.
GENERAL ELECTRICAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE
2014 NATIONAL ELECTRIC CODE & SHALL CONFORM WITH THE
FLORIDA BUILDING CODE & ALL LOCAL CODES.
2. FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS,
DENS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS
TO HAVE ARC FAULT PROTECTION PER 2014 NEC SECTION 210.12 (B)
3. ALL 15 & 20 AMP RECEPTACLES IN KITCHENS, FAMILY ROOMS,
BEDROOMS, LIVING ROOMS, SUNROOMS, HALLWAYS, CLOSETS,
OR SIMILAR ROOMS OR AREAS TO BE OF THE TAMPER RESISTANT
TYPE PROTECTION PER 2014 NEC SECTION 406.11
4. GFI OUTLETS ARE TO BE INSTALLED IN THE KITCHEN, BATHROOM,
GARAGE, & OUTSIDE LOCATIONS AS NOTED (GR ON PLANS.
5. FINAL PLACEMENT OF ALL ELECTRICAL COMPONENTS TO BE
DETERMINED BY THE ELECTRICIAN OF RECORD IN ACCORDANCE
WITH THE 2014 NATIONAL ELECTRIC CODE & SHALL. CONFORM
WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES.
6. ENGINEER OF RECORD NOT RESPONSIBLE FOR ELECTRICAL PLANS
ALL fi'LUME31NCx, ELECTRICAL,
4 AG WORK TO FOLLOW THE
RESPECTIVE CSC 2011 6TH EDITION
CODES FOR EAG>}-I TRADE
'ALTERATION =LEVEL II
SCOPE OF PROJECT
THlS PROJECT /5 FOR ,4N INTERIOR RENOVATION
OF THE EXISTING BEDROOM FOR ,4 NEW 43-47'14ROOM
.441— ,4RE,45 OF WORK TO BE FlNl51-LED TO M.4TCN EXJSTING
ALL. WORK l5 TO BE DONE PER THE
FBC 2017 6714 EDITION PER THESE P/-,4N5.
DEFACED / DEL4MINATED CONCREi'E REPAIR
1.
REMOVE DELAMINATED OR OTHERWISE UNSOUND CONCRETE, FROM AREA
TO BE PATCHED, $AW CUT AS NECESSARY TO PREPARE AFFECTED AREA.
2,
DO NOT CUT REINFORCING STEEL, IF REINFORCING STEEL IS REVEALED
EL£CTRIGAL
REMOVAL SHALL CONTINUE UNTIL 4" OF REINFORCING STEEL IS REVEALED.
3.
REMOVE CONCRETE AROUND REINFORCING STEEL APPROX, 1" AROUND
EXHAUST FAN LIGHT
RELOCATE
EXISTING f'LLLME31NCs
a ELECTRICAL
TO NEW LOCATION
� .FOR THE BATHROOM
oNLY NEu/
ELECTR/CA,L lS aN0/UN
,4UD/T/ON.dL ELEGTR/GAL
MAY BE ADDED A8 NEEDED
PER FBG GODS
BY THE ELGTR/G/AN
OF RECORDNEW
_p _
� r
iY1
n , ,
I1111
�\ II¢II EXISTING
/ II II W OW
TYPICAL 2x4 WALL:
N BF 1/2" DRYWALL
TAPED < SANDED
(DUROCK FOR WET AREAS)
INTERIOR 2x4 STUDS * 16" o.c.
NON BEARING WALLS 1/2° DRYWALL
TAPED < SANDED.
PAINTED TO MATC �^����
EXISTING O ,
INTERIOR WALLS EXISTING A��
't C88 WALLS
t0 REMAIN TO REMAIN
DASHED / REVIEWED FQh
rA
EXISTING BEDROOM'..
/121-011
EXISTING
NEW 5ATHROOM RENOVATION FLOOR PLAN
SCALE, I/4' . I'-0"
CODE COMPLIANt'
ST. L.I.nCIE CC?U`°'
Copyright 2020
ROBERSON
DESIGN GROUT'
All rights reserved.
REVISION DATE
JOB " 2091
DATE : 8/6/20
PRAWN BY SR
SHEET
1 Of 1