Loading...
HomeMy WebLinkAboutTrussil ®=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. ALL. TRUSSES AI?E TO BE SET DON'T LIFT TRUSSES AT 2"-O OI\CENTER WITH SPANS LONGER THAN EXGEF- AS NOTED 30' BY THE PEAK. Ito CONSULT BCSI MULTIPLE PLY TRUSSES MUST BE ASTENED TOGETHER PER ENGINEERING BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE A IF MULTIPLE PLY. A 30' Span Iorless A& T 53 degrees or less Tcc Line sPe� 'cpprcx. REFER. TO B�S' Tr,is must be set pis way c c e used ti§s 's a ex mple, yow tress May not matcn- Insst crone operotor setstross the way. 30, to 60' Span A Spreader Bar 4ag *-- APproK 2/3 to._-' Lme 1/2 of Span REFER TO I Jss .at be set this way if crane used. This Is an example, truss may not match... .Insist crane operator sets truss this. way. All load bearing walls, headers, beams & lintels must be in place at indicated height before trusses Q are installed. Ai AIR HAIVC�I-�R �0�� UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. Carrying Girder For Truss to Truss Connections see hanger/connector Nails must be as shown. Guide tabs o schedule in engineering Dome angle nails. package. Carried Truss r rc vor eevEiEo. ARENOTSEVEs ENGINEEPINC EKGsR."IW MZ J a 2£S O 24'Oa. rHRu CORNER JACKS V'116 L ONLY . q. CORNER DETAIL OVERHANGS NOT SHOWN FOR CLARITY SEAT PLATES BY CHAMBERS I INDICATES LOAD BEARING REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 8'-1" ABOVE FINISHED FLOOR ® ARRANGE WITH RAN OPERATOR I ADVANCE FOR A SPREADER BAR OF 118' - 24' IN LENGTH Do not stand on trusses until they are braced per I & properly nailed to straps & hangers heel=315/16" 15'-10" PLUMB CUT END 2 x 4 Top Chord — BEARING HEIGHT 8'-l" TYPICAL END DETAIL FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED a RETURNED The legal description of the property where the trusses will be Installed is: The undersigned ecknowledgea and agrees; t: Trusses will be made In strict accordance with this truss placement diagram layout, which Is the sole euthodry, for detarmining. successful fabdcatton of the trusses. . 2. All dlmensbns In this layout have been verified by 1Fie undersigned .3. Unleab wnden nodes Is provided by cardfied mall to Chambere Truss wRhln ten (10) days of delhrery the undersigned agrees that no beckchargee will be ellowed..ln the event such written nodes Is fumlehed Chambers Trues shell have three (3) bussjjneaa days in welch to begin repalre required, or to substitute oNec trusses, at Chambers optlsn. 4. The undersigned acknowledges receipt of "BCSI 1-03' summery sheet by TPI 8 WiCA. deIs llveryuChambereJTNas heat the aoele authority to detennmloathe au� bllRy of the jobtalte iefor portion of the Job she for delivery, Chambere as will be responsible for dump delivery only. The buyer Is responsible for addldona(del Nsrr expenses tl Chambers Truss has to redelNer I because Job aria Is riot proparod for delivery or buyer Is not prepared for delivery of trusses, Buyer Is reaponalble to Chambers TNec for towing costa due to site conditions, S. Price as shown Iq paregraph 7 below Is eubJeq to change If any changes are. made In this layout. A $50 per hour fee for revisions may be charged by Chambers Truss. ' 7: This Is a PURCHASE ORDER to Chambers, Trues of the sum agreed to or M na:. agreement a reasonable price, Involee will be made on delivery and paid within terms o/ net on delivery. Invoice may, be made at scheduled date of delivery tl buyer cannot eccepT delivery of fabricated trusses. The undersigned agrees to pay Chambere.TNss reasonable ettomey's tee for eolleglbne In event of payment not timely made. 1-t2 °%per month servJce ' charys will be added for all sumo not paidwithinteens. B. Signature or Initials anywhere on this sheet constitutes agreement to all tense herein. Ban consideration at Chambers Truss extending credit for this material the undersigned uncondltlonelly guarantees payment when due of any and all Indebtedness owed to Chambers TNsa by any eerily receiving material and Na undersigned agrees to pay such Indebtedness Inqu•Ing attorneys tees, tl default In payment for material be made by the regpleM. `_ -te. In the avant o1 any 1Rlgatlon concerning this agreement, the kema furnished hereunder or payments referred to herein, the, parties ogres that the sole venue for any such adios will f be Se1M l.uge County, Plonde. 11. Design respons1b111Gea are per 'National Standard And Recommended Guidelines On Raeponslbllltlea For Construction Using Metal Plate Connected Wood Trusses ANSI/rPIM/rCA 4 - 20a2" DATED . SIGNED , POR__.. TfRE Aspre.'tde+' barmayba required Per'"SCSI 1-03" th prevent Iry'ta'y8 damage. Multiple Iply trusses must be fastened together per engineering before they are set; failure to do so can result In roof collapse. Temporary and permanent bracing are required and ran save life and properly and Is the responslblllty of the truss erector. 'Study the contents of the Information packet Included on delivery before setting trusses. ` Trt�ses must be set and braced par design to prevent injury �, l�ytage, Trusses must be sat plumb and square Do not set bunks or stack of plywood, roofing material or any -other concentrated loads on trusses, this can cause collapse. DO NOT SET TRUSSES USING THIS LAYOUT USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES Cl�]AMBERS TRUSS INC 3105 Oleander Avenue Fort Pierce; Florida 34982-6423 800-551-5932 Fort Pierce 772r485-2012 Fax 772-465-8711 Vero Beach 772569.2012 Stuart 772-288J302 ' ,.°-� sera.,. ruwunroerorlsST.nM 0 The Architect's or Architect's reprnsentafive's. shop drawing approval is NOTa, "double check" of the contraetpn The contractor shall remain respolIhsible for checking field measuremant g. and .other construction criteria. Architect's approval covers general roof shape, review of truss strapping, an loading on ' structure from gravity and uplift loads and their. res 'tivelocati ns j Approved � `"D ,Date: Braden ii BradenA.1.A. P.A.- 92.0/93.2 MITEK 42 DESIGN CRITERIA County SAINT LUCIE Building Department ST LUCIE COUNTY + Wind Design Criteria ASCE 7-2010 -� Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 — w Roofing Material Metal Roof y 2 Loading in PSF Roof R.D.L.. fr'I ° Top Chord Live 20 o � c � Top Chord Dead 7 4.2 L N Bottom Chord Live 10 Non -Concurrent w � Bottom Chord Dead 10 3 d � TOTAL Load 37 7.2 —' Duration Factor 1.25 � J Wind Speed 165mph 3 � �✓` Top Chord C.B. Sheeting by builder. U Bottom Chord C.B. Sheeting by builder. Highest Mean Height 12'-0" .Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 R.D.L.=Restrainin Dead Load C.B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Buildin Desi per and/or Engineer of Record. �/ Chambers Truss Inc. Drawing Name: M11324 L� Scale: 1 /4 = 1' L 83 total trusses, 27 different trusses. MI 4: SAE AGAD: SAE Reviewed Da1ie:07l19/12 Revised: 03/21118 �B F('(-� Revised 3105/2fJ20 WYNNE BUILDING CRP. DESGRIPTI®N: 7lo�atl GARAGE RIGHT CODE COIi � NC:RI�YALE OJT. �-U aC�I/E C NT PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 27 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT 1324 � oat Gl Al Al Al Al 04 (10 GRB , 16 N < f0 an m m m m m ap m a0 m a7 fD 7 N � � r i.V J2 N J2 O J6 III I A2 I � � I s I Al N 1� I IN 13'-72" Al I I A I I : Al I Al A A S �Wc.) � V O A WmQ Z zl q 0 N r� T SETBACK BOSTON HIP TRJSS I � ' I ill- v rJ3 .— B I I I I � I a i I 35' REVI MiTek` ; RE: ml1324 MiTek USA, Inc. THE ROYALE 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer: WYNNE BUILDING CORPORATION Project Name: ml 1324 Lot/Block:. Model: ROYALE Address: UNKNOWN Subdivision: City: ST LUCIE State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 27 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date No. Seal# Truss Name Date 1 T19781776 A 4/22/2020 21 T19781796 JC 4/22/2020 2 T19781777 Al 4/22/2020 22 T19781797 KJ5 4/22/2020 3 T19781778 A2 4/22/2020 23 T19781798 KJ8 4/22/2020 4 T19781779 A3 4/22/2020 24 T19781799 KJA 4/22/2020 5 T19781780 A4 4/22/2020 25 T19781800 KJB 4/22/2020 6 T19781781 A6 4/22/2020 26 T19781801 MV2 4/22/2020 7 T1978178 B 4/22/2020 27 T1MV 0 9 8 T19781783 BHA 4/22/2020 1 � 9 T19781784 GRA 4/22/2020 10 T19781785 GRB 4/22/2020 11 12 T19781786 T19781787 GRC J1 4/22/2020 4/22/2020 REVIEWED FOR 13 T19781788 J2 4/22/2020 COMPLIANCE 14 T19781789 J3 4/22/2020 CODE ST. LUCIE COUNTY 16 T197817911 J5 4/22/2020 17 T19781792 J6 4/22/2020 S®CC 18 T19781793 J8 4/22/2020 19 T19781794 JA 4/22/2020 20 T19781795 JB 4/22/2020 This item has been electronically signed and sealed by ORegan, Philip using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision ,,����jf1111j������ based on the parameters provided by Chambers Truss. ��� �Q • Truss Design Engineer's Name: ORegan, Philip ��%% N . 0 E N sF�y2 My license renewal date for the state of Florida is February 28, 2021. Florida COA: 6634 No 5 8126 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verity applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. T -33:. STATE OF •:��/ Al 11111 Philip J. O'Regan PE No.58126 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 April 22, 2020 1 of 1 ORegan, Philip w Job Truss Truss Type Qty Ply THE ROYALE T19781776 M11324 A COMMON 10 1 R Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:64:17 2020 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-bdFkwKP1 W Vd5kvh4gXmgUQgkzjKtK4bfmPcjgXzXjGq 1-0-0 8-4-0 12-11-0 17 6-0 22-1-0 26-8-0 35-0-0 6-0 -0-0 8-4-0 4-7-0 4-7-0 4-7-0 4 7-0 8-4-0 0-0 4.00 12 4x5 = Scale=1:59.3 17 '" 15 `" `" 14 '" 12 46 — 2x3 II 5x6 WB = 3x8 = 2x3 II 4x5 = 3x8 = 5x6 WB = 84-0 12-11-0 22-1-0 26-8.0 35.0-0 8� 4-0 7-0 9-2-0 4 7-0 8-4-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.33 14-15 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -0.64 14-15 >652 240 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) 0.13 10 n/a n/a BCDL 10.0 Code FBC2017lrP12014 Matrix -MS Weight: 169 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1399/0-8-0, 10=1399/0-8-0 Max Horz 2=-223(LC 8) Max Uplift 2=-775(LC 10), 10=-775(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3404/2226, 3-5=2807/1885, 5-6=-2801/1990, 6-7=-2801/1990, 7-9=-2807/1885, 9-10=3404/2226 BOT CHORD 2-17=1946/3218, 15-17=-1946/3218,'14-15=-1116/2053, 12-14=-1946/3188, 10-12=-1946/3188 WEBS 6-14=-598/1034, 7-14=-252/246, 9-14=-702/541, 6-15=-598/1035, 5-15=-253/246, 3-15=701 /541 Structural wood sheathing directly applied or 3-1-13 oc purlins. Rigid ceiling directly applied or 4-10-7 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Exterlor(2)12-8-6 to 17-6-0, Interior(1) 22-1-0 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at joint 10. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-B9 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE T19781777 M11324 Al SPECIAL �Qty 9 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.13u s Mar 11 LU18 Mi l ek inoustnes, mc. i ue Mar z4 iz:b4:ld 2u2Q rage 1 ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-3gp67gQfHplyL3GGEEHvldDr47c?3X1o?3LGM 7-XjGp 1-0-0 7-8-0 13-7-8 17 6-0 23-11-12 26-9-10 35-M 6-0 -0-0 7.8-0 5-11.8 3-10-8 6-5-12 2-9-14 8-2-6 1-0-0 Scale = 1:60.3 3x5 = 5x8 MT18HS = 4.00 12 14 13 2x3 11 5x12 = 2.00 12 LOADING (psi) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC20171TP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 6-12: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 10=1349/0-8-0 Max Horz 2=-223(LC 8) Max Uplift 2=-825(LC 10), 10=-825(LC 10) 35-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES TC 0.89 Vert(LL) 0.80 12 >525 360 MT20 BC 0.94 Vert(CT) -1.39 12-13 >302 240 MT18HS WB 0.62 Horz(CT) 0.37 10 n/a n/a Matrix -MS Weight: 159 lb BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 6-12 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3309/2433, 3-5=2581/2012, 5-6=-2548/2113, 6-7=-5337/4002, 7-9=-5302/3868, 9-10=-5702/4143 BOT CHORD 2-14=-2151/3113, 13-14=-2151/3113, 12-13=-1450/2202, 10712=-3809/5431 WEBS 3-14=0/265, 3-13=-B13/590, 5-13=-269/317, 6-13=-317/567, 6-12=-2362/338B, 7-12=-298/368,9-12=-405/352 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. Il; Exp C; Encl., GCpj=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Exterior(2) 12-8-6 to 17-6-0, Interior(1) 22-3-10 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = I O.Opsf. 6) Bearing atjoint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 10. 3x12 Zz GRIP 244/190 244/190 FT = 0% This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev, 1010312015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addtional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply THE ROYALE T19781778 PM11324 A2 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Tue Mar 24 12:54:19 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-XONULORH26uozDrSoy0 8Zri3jXxjoyGyEj5gvQzXjGo 1-0- 8-0-1 13-7-8 16-0-0 19-0-0 23-11-12 26-9-9 35-0-0 6-0- ON 8-0-1 5 7-7 2-4-8 3-M 4-11-12 2-9-13 8-2-7 -0-0 Scale = 1:62.3 4.00 12 5x6 = 4x4 = 3x8 5x10 7 5x6 34 8g 22 23 12 2 10 11 4 13 6x10 MT18HS = [ '- 14 3x10 15 3x5 2x3 II 5x6 = 3x12 = 2.00 12 9-0-0 23-11-12 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) 0.75 12 >559 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -1.02 12-21 >412 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.75 Horz(CT) 0.37 10 n/a n/a BCDL 10.0 Code FBC2017rTP12014 Matrix -MS Weight: 160 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-4-8 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-13 REACTIONS. (lb/size) 2=1349/0-8-0, 10=134910-8-0 Max Horz 2=-205(LC 8) Max Uplift 2=-825(LC 10), 10=-825(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3315/2113, 3-5=-2515/1641, 5-6=-2524/1699, 6-7=-2672/1734, 7-9=-5246/3199, 9-10=5687/3567 BOT CHORD 2-15=1849/3111, 14-15=-1849/3111. 13-14=1217/2314, 12-13=-2804/5025, 10-12=-3257/5414 WEBS 3-15=0/300, 3-14=-954/692, 5-13=-206/561, 6-13=-357/632, 7-13=-2796/1678, 7-12=1082/1957, 9-12=-479/463 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members. electronically signed and 7) Bearing at joint(s) 10 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify sealed by ORegan, Philip, PE capacity of bearing surface. using a Digital Signature. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at printed copies of this P joint 10. document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE T19781779 M11324 A3 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:20 2020 Page 1 ID: _kfiGCA6bx7j2Syl HDXFw7ye3KX-7CxsYMSvpQOfbNQfLfJN62IEjxHyXPZ5SNgNRszXjGn �1-0-0 8-0-1 14-M 21-0-0 1-1 1-1 , 26-9-10 35-0-0 3s-o-a -0-0 8-0-1 5-11-15 7-0-0 2.11-12 2-9-14 8-2-6-0-0' 3x5 = 5x6 = 4x6 = Ann ri—q- 4 b 'WA 13 " 2x3 11 5x6 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017frP12014 2.00 12 CSI. DEFL. in (loc) Udefl Ud TC 0.69 Vert(LL) 0.72 10 >582 360 BC 0.98 Vert(CT) -0.98 10-19 >427 240 WB 0.74 Horz(CT) 0.35 8 n/a n/a Matrix -MS LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 8=1349/0-8-0 Max Horz 2=-181(LC 8) Max Uplift 2=-825(LC 10), 8=-825(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3286/2122, 3-4=2556/1711, 4-5=-3161/2095, 5-6=-3304/2150, 6-7=-5214/3232, 7-8=5695/3643 BOT CHORD 2-13=1853/3079, 12-13=-1853/3079, 11-12=-1338/2410, 10-11=-2826/4982, 8-10=-3331/5422 WEBS 3-13=0/293, 3-12=-854/595, 4-11 =-480/959, 5-11 =-360/724, 6-11 =-2280/1355, 6-1 0=1 118/1934, 7-1 0=-530/51 5 Scale = 1:61.3 3x12 PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 158 lb FT = 0% Structural wood sheathing directly applied or 2-5-0 oc pudins. Rigid ceiling directly applied or 2-2-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Extedor(2) 31-2-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 8. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 8634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE T79781780 M11324 A4 SPECIAL �Qty 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:22 2020 Page 1 ID:—kfiGCA6bx7j2Syl HDXFw7ye3KX-xb2ci2T9L1 GNggal T4MrBTNaQkzc?IfOwhJU WIzXjGI 1-0-0 6-5-8 12-0-0 17-8-4 23-0-0 2 11-1 26.9-9 35-0-0 6-0- -0-0 66 5-8 5-6-8 5-8-0 5-3-12 0-11-1 2%-13 8-2-7 -0-0 4.00 12 3x6 = 5x6 = 3x4 = 14 13 3x4 3x4 = 5x6 = 2.00 12 5x8 =2x3 II 6 7 Scale = 1:61.3 3x12 - 8-8-2 13.7-8 17-6-0 23-11-12 35-0-0 8-8-2 4-11-6 3-10-8 6-5-12 11-0-4 Plate Offsets (X,Y)— [2:0-0-6,Edge], [6:0-4-0,0-2-3], [9:0-1-15,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.73 11-12 >572 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -0.98 11-20 >429 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.77 Horz(CT) 0.36 9 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MS Weight: 160 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-8-0 Max Horz 2=157(LC 9) Max Uplift 2=-825(LC 10), 9=-825(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3367/2256, 3-4=-3093/2069, 4-5=-2645/1853, 5-6=-3425/2347, 6-7=-5165/3301, 7-8=-5219/3301, 8-9=5704/3714 BOT CHORD 2-14=2000/3170, 13-14=-1488/2537, 12-13=-2065/3480, 11-12=-2440/4196, 9-11=-3399/5431 WEBS 3-14=-429/415, 4-14=-323/584, 4-13=-142/386, 5-13=-1125/697, 5-12=-141/467, 6-12=861/437, 6-11 =-1 145/2016, 8-11=-542/518 Structural wood sheathing directly applied or 2-5-6 oc purlins. Rigid ceiling directly applied or 2-2-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 Ito uplift at joint 9. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 69D4 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED M1TEK REFERENCE PAGE MI1-7473 rev. 10/03/2015 BEFORE USE. �— Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply THE ROYALE T79781781 M11324 A6 HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:23 2020 Page 1 ID:_kriGCA6bx7j2Syl HDXFw7ye3KX-Pnc?AOUo6LOESg9E1 nt4khwkW8Mmkt1Y9L312BzXjGk �1-0-0 6-7-15 !I--' 0-0-0 13-8-0 21-4-0 25-0-0 28 4-0-1 1 `35-0-0 0-0 6-7-15 3 4-1 3.8.0 7-8-0 N 3--1 6-7-15 -0-0 �1 6 4x5 = 5x8 = 24 .II 2x3 II 5x8 = 4.00 12 4 23 24 5 25 26 6 27 28 7 16 15 14 13 12 11 3x4 = 4x6 = 3x4 = 3x4 = 4x6 = 3x4 = 10-M 1311 21-4-0 25-0-0 35-0-0 ' 10-0-0 3-6-0 7.8-0 3-8-0 10-0-0 Plate Offsets (X,Y)— [2:0-1-14,Edge], [4:0-5-4,0-2-8], [7:0-5-4,0-2-8], [9:0-1-14,Edge] LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 TCDL 7.0 Lumber DOL 1.25 BC 0.71 BCLL 0.0 Rep Stress Incr YES WB 0.31 BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1118/0-8-0, 14=379/0-8-0, 9=1201/0-8-0 Max Hors 2=-133(LC 8) Max Uplift 2=-692(LC 10), 14=-219(LC 10), 9=-739(LC 10) Max Grav 2=1118(LC 1),14=454(LC 19). 9=1 206(LC 20) Scale = 1:60.3 4x5 = DEFL. in (too) I/deft Ud PLATES GRIP Vert(LL) 0.6011-13 >424 360 MT20 244/190 Vert(CT) -0.78 13 >328 240 Horz(CT) 0.11 9 n/a n/a Weight: 153 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 4-6-3 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2600/2341, 34=-2215/1960, 4-5=-2527/2290, 5-6=-2527/2290, 6-7=-2527/2290, 7-8=-2531/2224,8-9=-2880/2572 BOT CHORD 2-16=-2074/2444, 14-16=-1569/2065, 13-14=-1968/2527, 11-13=-1833/2382, 9-11=-2290/2707 WEBS 3-16=-495/599, 4-16=-206/347, 4-14=-541/820, 5-14=-526/591, 6-13=-234/311, 7-13=1821282, 7-11 =-355/492, 8-11 =-444/551 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 16-9-7, Interior(1) 16-9-7 to 18-2-9, Exterior(2) 18-2-9 to 25-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 692 lb uplift at joint 2, 219 lb uplift at joint 14 and 739 lb uplift at joint 9. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verfly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIF7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall �..r. iTek- It building design. Bracing Indicated is to prevent buckling of individual truss web andfor chord members only. AddiOonal temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the iVl fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPIf quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply THE ROYALE T79781782 M11324 B COMMON 3 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:24 2020 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-uzANOjVQtfW53JQaVOJGuT?gYo2TNIhN?oaadzXjGj -1-0-0 6-11-0 13-10-0 1�+ 6-11-0 6-11-0 Scale: 1/2"=1' 46 = 1 1A 5 2x3 11 0 3x4 = 3x4 = 6-11-0 13-10-0 6-11-0 6-11-0 Plate Offsets (X,Y)— [2:0-2-10 Edge] [4:0-2-10,Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 - TC 0.37 Vert(LL) 0.10 5-8 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.33 Vert(CT) -0.13 5-8 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(CT) 0.01 4 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MS Weight: 47 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 7-7-1 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=510/0-8-0, 2=568/0-8-0 Max Horz 2=93(LC 9) Max Uplift 4=-292(LC 10). 2=-377(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-967/954, 3-4=-966/952 BOT CHORD 2-5=785/883, 4-5=-785/883 WEBS 3-5=84/315 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45tt; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 292 lb uplift at joint 4 and 377 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. VRegan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 ® WARNING - Verlly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall p qr It building design. Bracing Indicated Is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing IYI iT®k- is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-69 and BCS/ Building Component 6904 Parke East Blvd. Safetyinformadon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply THE ROYALE T19781783 M11324 131-17 BOSTON HIP 1 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:25 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-MAklb3W2dyeyh8lc8CvYp6?4vy5bCkwgcfY864zXjGi 15-" 21-6-0 1-0-0 7-0-0 9.6-0 11.6-0 13-M 1 -017-6-0 19-6-0 21-0-0 23-6-0 25-6.0 28.0-0 35-0-0 -0.0 7-0-0 2-6-0 2-0-0 2-0-0 016 1-6-0 2-0-0 2-0-0 1-6.00-6 2-0-0 2-0-0 2.6-0 7-0-0 -0-0 Scale = 1:62.6 35 3x5 = 4.00 12 5x6 = — 33 46 = 3x8 = 12 14 16 32 -' 3x4 = 4x6 = 30 3x6 = 7-0-0 14-0-0 21-0-0 28-0-0 35-0-0 7-0-0 7-0-0 7-007-0-0 7-0-0 Plate Offsets (X,Y)— [2:0-1-2,Edge), [28:0-0-2,Edge) LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.72 Vert(LL) 0.51 32-33 >826 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.56 Vert(CT) -0.67 32-33 >628 240 BCLL 0.0 Rep Stress Incr YES WB 0.48 Horz(CT) 0.14 28 n/a n/a BCDL 10.0 Code FBC2017lrP12014 Matrix -MS Weight: 208 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-8-6 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-6-1 oc bracing. WEBS 2x4 SP No.3 JOINTS 1 Brace at Jt(s): 11, 18, 15, 7, 23 REACTIONS. (lb/size) 2=1349/0-8-0, 28=1349/0-8-0 TOP CHORD MUST BE BRACED BY END JACKS, Max Horz 2=223(LC 8) ROOF DIAPHRAGM, OR PROPERLY CONNECTED Max Uplift 2=-825(LC 10), 28=-825(LC 10) PURLINS AS SPECIFIED. FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3392/2640, 3-4=1213/956, 4-8=-1157/946, 8-9=-1145/979, 9-12=-112211028, 12-14=-1125/1090,14-16=-1124/1089,16-19=-1121/1028,19-22=-1145/979, 22-26=-1157/946, 26-27=-1214/956, 27-28=-3393/2641, 3-5=-2373/2046, 5-7=-2376/2050, 7-10=-2376/2050, 10-11=-2376/2050, 11-13=-2376/2050, 13-15=-2376/2050, 15-17=-2376/2050, 17-18=-2376/2050, 18-20=-2368/2046, 20-23=-2368/2046, 23-25=-2368/2046,25-27=-2364/2041 BOT CHORD 2-35=-2358/3190, 33-35=-2360/3166, 32-33=-2652/3448, 30-32=-2361/3167, 28-30=-2358/3191 WEBS 3-35=0/284, 27-30=0/285, 3-33=-317/378, 18-33=-466/474, 27-32=-312/353, 14-15=405/437 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 10-8-9, Exterior(2)10-8-9 This item has been to 17-6-0, InteNor(1) 24-3-7 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 electronically signed and 3) Provide adequate drainage to prevent water ponding. Sealed by ORegan, Philip, PE 4) All plates are 2x3 MT20 unless otherwise indicated. Using a Digital Signature. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' Printed copies of this 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. document are not Considered 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at signed and sealed and the joint28. signature must be verified 8) Graphical purlin representation does not depict the size or the orientation of the purin along the top and/or bottom chord. on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cart 8634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall q� building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing WOW iTe k• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply THE ROYALE T19781784 M11324 GRA SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:27 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-1YsV01X19augwRS7GdxOuX5Zrlrvglw73z1 FByzxGg 1 0 0 4-1-8 5-71 8.2-13 9-8-8 13-10-0 14-10-0 1-0-0 4-1-8 1-5 11 2-7-9 1-5 11 4-1-8 1 0 0 Scale=1:26.6 2.37 12 4x4 = 44 = 4x10 4x10 19 4 20 21 5 22 6 zz 0 3x4 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017frP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=77010-8-0, 7=770/0-8-0 Max Horz 2=-65(LC 6) Max Uplift 2=-523(LC 8), 7=523(LC 8) Max Grav 2=787(LC 17), 7=787(LC 18) 2x3 II 3x4 = 3x4 = 2x3 II CSI. DEFL. in (loc) I/dell Lid TC 0.18 Vert(LL) 0.08 11 >999 360 BC 0.32 Vert(CT) -0.10 10 >999 240 WB 0.06 Horz(CT) 0.03 7 n/a n/a Matrix -MS 3x4 = PLATES GRIP MT20 244/190 Weight: 58 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 5-4-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-0-4 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1798/1192, 3-4=1761/1197, 4-5=-1724/1169, 5-6=1761/1190, 6-7=-1798/1137 BOT CHORD 2-12=-1083/1685,11-12=-1082/1692,10-11=-1112/1724,9-10=-1024/1692, 7-9=1028/1685 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate gdp DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 523 lb uplift at joint 2 and 523 lb uplift at joint 7. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 63 lb down and 114 lb up at 4-1-8, 85 lb down and 124 lb up at 5-0-0, 113 lb down and 146 lb up at 5-7-3, 60 lb down and 129 lb up at 5-11-0, 60 lb down and 129 lb up at 7-11-0, 113 Ito down and 146 lb up at 8-2-13, and 85 lb down and 124 lb up at 8-10-0, and 63 lb down and 139 lb up at 9-8-8 on top chord, and 6 lb down and 7 lb up at 4-1-8, 18 lb down and 15 lb up at 5-0-0, 33 lb down at 5-7-3, 39 lb down at 5-11-0 , 39 lb down at 7-11-0, 33 lb down at 8-2-13, and 18 lb down and 15 lb up at 8-10-0, and 6 lb down and 7 lb up at 9-8-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-4=-54, 4-5=-54, 5-6=-54, 6-8=-54, 13-16=-20 Concentrated Loads (lb) Vert: 3=7(B) 4=-64(B) 5=-64(B) 6=7(B) 12=6(121) 11=35(B) 10=-35(B) 9=-6(B) 19=-28(B) 20=60(B) 21=-60(B) 22=-28(B) 23=18(B) 24=-18(B) m I" This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - VeNly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 1`010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS87P/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE T19781785 M11324 GRB SPECIAL �Qty 1 1 Job Reference (optional) unamoefs I fuss, Inc., ron rlerce, rL o. ISU s Mar -,-, LUI0 IVII1 ex Inuustnes, inc. i ue ,Vlar L9 Ic[09:co cucu rdye r • ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-mlQuE5YwwtOXYbl BpLSFRkdg49ACP4oHldmojOzXjGf 0 5-0-0 10 3-0 15 6-0 21.6.0 26-2-0 28-1-0 35 0-0 36-0 q 0-0 5-0-0 5.3-0 5.3-0 60 -0 4 8 0 1-11-0 6 11-0 Scale=1:62.4 2x3 11 4x4 = 4.00 12 4x8 = 3x4 = 3x6 = 2x3 II 4x4 = 9 3 25 26 4 27 28 29 5 630 31 32 733 34 35 a ,n1 2 n 10 11 N }j��J 0EE0 I-. 18 36 37 17 38 16 39 42 14 4313 12 3x4 = 2x3 II 3x4 = 3x6 = 5x1 _4041 3x4 =3x6 = 30 30 = 5-0-0 10-3-0 15-6-0 21-6-0 28-1-0 35-0-0 5 0-0 5-3-0 6-0-0 6-7-0 6-11-0 Plate Offsets (X,Y)— [3:0-5-4,0-2-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.41 Vert(LL) 0.11 17-18 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.14 17-18 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.53 Horz(CT) 0.03 10 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MS Weight: 146 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-4-6 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at micipt 4-15 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=96(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 2=-536(LC 8), 15=-846(LC 8), 14=-555(LC 8), 10=-314(LC 8) 1 Max Grav All reactions 250 lb or less atjoint(s) except 2=787(LC 17), 15=1322(LC 1), 14=927(LC 1), 10=506(LC 14) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-1773/1106, 3-4=-1406/944, 4-6=-304/595, 6-7=-304/595, 7-8=-304/595, 8-9=-702/344, 9-10=-719/323 BOT CHORD 2-18=-96211659, 17-18=-958/1675, 15-17=-843/1406, 14-15=-595/429, 12-14=-158/622, 10-12=-196/636 WEBS 3-18=0/331, 3-17=-297/158, 4-17=0/362, 4-15=2076/1313, 6-15=505/480, 7-14=-431/408, 8-14=-10631625. 8-12=115/265 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 536 lb uplift at joint 2, 846 lb uplift at joint 15, 555lb uplift at joint 14 and 314 lb uplift at joint 10. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 257 lb down and 341 lb up at 5-0-0. 100 lb down and 129 lb up at 7-0-12, 100 lb down and 129 lb up at 9-0-12, 100 lb down and 129 lb up at 11-0-12, 100 lb down and 129 lb up at 13-0-12, 100 lb down and 129 lb up at 15-0-12, 100 lb down and 129 lb up at 17-0-12, and 100 lb down and 129 lb up at 19-0-12, and 100 lb down and 129 Ib up at 21-1-4 on top chord, and 83 lb down at 5-0-0, 39 lb down at 7-0-12, 39 lb down at 9-0-12, 39 lb down at 11-0-12, 39 lb down at 13-0-12, 39 lb down at 15-0-12, 39 lb down at 17-0-12, and 39 lb down at 19-0-12, and 39 lb down at 21-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not ��®® a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing WOW is always required for stability and to prevent collapse with.possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/f Quality Criteria, DSB49 and SCSI Building Component 6904 Parke East Blvd. Safety lnformallon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa. FL 36610 Job Truss Truss Type City Ply THE ROYALE T19781785 M11324 GRB SPECIAL 1 1 Job Reference (optional) I Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:28 2020 Page 2 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-mlQuE5YwwtOXYbl BpLSFRkdg49ACP4oHldmojOzXjGf LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-54, 8-9=-54, 9-11=-54, 19-22=-20 Concentrated Loads (lb) Vert: 3=-160(F) 18=A5(F) 25=-60(F) 26=-60(F) 27=-60(F) 29=-60(F) 30=-60(F) 31=-60(F) 32=-60(F) 33=60(F) 36=-13(F) 37=-13(F) 38=-13(F) 39=13(F) 40=-13(F) 41=-13(F) 42=-13(F)43=-13(F) ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II-7473 rev. f010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Iva I' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek♦ is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPN Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply THE ROYALE T19781786 M11324 GRC HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:30 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-i7XeenZBSVGFnvBaxlVjW9jxmzm3tvGamxFvoHz)gGd 1-0-0 8-M 13-8-0 17-6-0 21-4-0 27-0-0 35-0-0 6-0 0-0 8-M 5-8-0 3-10-0 3-10-0 5 8 0 M-0 -0-0 Scale=1:60.3 5x8 MT18HS = 5x8 MT18HS = 4.00 12 2x3 11 3x8 = 3x6 = 2x3 II 3 23 24 25 426 27 285 6 729 30 31 32 8 16 33 15 14 34 35 36 37 13 38 12 39 11 3x5 = 2x3 II 3x6 = 6x10 = 6x10 = 3x6 = 2x3 II 3x5 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 4-14,7-13: 2x6 SP No.2 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TC 0.71 Vert(LL) 0.2211-22 >999 360 MT20 244/190 BC 0.67 Vert(CT) -0.31 13-14 >830 240 MT18HS 244/190 WB 0.79 Horz(CT) 0.05 9 n/a n/a Matrix -MS Weight: 157 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-5-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-9-3 oc bracing. WEBS 1 Row at midpt 3-14. 5-14 REACTIONS. (lb/size) 2=412/0-8-0, 14=3582/0-8-0, 9=1192/0-8-0 Max Horz 2=-109(LC 6) Max Uplift 2=-299(LC 8), 14=-2133(LC 8), 9=764(LC 8) Max Grant 2=423(LC 17), 14=3582(LC 1), 9=1194(LC 18) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=377/225, 3-4=-1093/1954, 4-5=-109311954, 5-7=-1943/1220, 7-8=-1943/1220, 8-9=-2776/1671 BOT CHORD 2-16=-154/317,14-16=-160/350,11-13=-1475/2624,9-11=-1464/2591 WEBS 3-16=-200/679, 3-14=-2514/1528, 4-14=-641/586, 5-14=-2674/1707, 5-13=-1124/2080. 7-13=-592/548, 8-13=-760/483, 8-11=-201/684 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 299 lb uplift at joint 2, 2133 lb uplift at joint 14 and 764 lb uplift at joint 9. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 182 lb down and 312 lb up at 8-0-0. 107 lb down and 173 lb up at 10-0-12, 107 lb down and 173 lb up at 12-0-12, 107 lb down and 173 lb up at 14-0-12, 107 lb down and 173 lb up at 16-0-12, 107 lb down and 173 lb up at 16-114, 107 lb down and 173 lb up at 18-11-4, 107 lb down and 173 lb up at 20-11-4, 107 lb down and 173 lb up at 22-11-4, and 107 lb down and 173 lb up at 24-11-4, and 182 lb down and 312 lb up at 27-0-0 on top chord, and 411 lb down and 242 lb up at 8-0-0, 79 lb down and 1 lb up at 10-0-12, 79 lb down and 1 lb up at 12-0-12, 79 lb down and 1 lb up at 14-0-12, 79 lb down and 1 lb up at 16-0-12, 79 lb down and 1 lb up at 16-11-4, 79 lb down and 1 lb up at 18-11-4, 79 lb down and 1 lb up at 20-11-4, 79 lb down and 1 lb up at 22-11-4, and 79 lb down and 1 lb up at 24-11-4, and 411 lb down and 242 lb up at 26-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �g'e a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing pn AA T IYIi lt�n• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPIf quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE T19781786 M11324 GRC HIP �Qty 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8,130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:30 2020 Page 2 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-17XeenZBSVGFnvBaxlVjW9jxmzm3tvGamxFvoHzXjGd LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-54, 8-10=-54, 17-20=-20 Concentrated Loads (lb) Vert: 3=-126(B)6=-107(B)8=-126(B)15=-50(B)16=-411(B)11=-411(B)12=-50(B)23=-107(B)25=-107(B)26=-107(B)27=-107(B)28=-107(B)29=-107(B) 30=-107(B) 32=-107(B) 33=-50(B) 34=-50(B) 35=-50(B) 36=-50(B) 37=-50(B)38=-50(B) 39=-50(B) ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply THE ROYALE T19781787 M11324 J1 MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:31 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-AK5Os7apDoO5P3mmVT0y3NFEuMGVcYtj_a?SK4zXjGc -1-0-0 1-0-0 1-0-0 1-M 3x4 = Scale = 1:6.1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/de8 Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 5 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 5 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017rTP12014 Matrix -MP Weight: 5 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical Max Horz 2=48(LC 10) Max Uplift 3=-4(LC 7), 2=-140(LC 10) Max Grav 3=11(LC 15), 2=118(LC 1), 4=17(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 13=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cart 6634 8904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall �e building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information avallabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE �Qty T19781768 M11324 J2 MONO TRUSS 4 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:31 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-AK5Os7apDoO5P3mmVTOy3NFEuMFhcYtj_a?SKjzXjGc -1-0-0 2-M i 1-0-0 2-M 3x4 = Scale = 1:7.8 2-0-0 2-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 Na n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MP Weight: 8 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=37/Mechanical, 2=141/0-8-0, 4=23/Mechanical Max Horz 2=67(LC 10) Max Uplift 3=-28(LC 10), 2=-136(LC 10), 4=-3(LC 7) Max Grav 3=42(LC 15), 2=141(LC 1), 4=31(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint 2 and 3 Ito uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply THE ROYALE T19781789 M11324 J3 MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:32 2020 Page 1 ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-fWf03TbR_6Wy1DLy2AXBbaoPemaML77sDEkOsAzXjGb 1-0-0 3-0-0 1-0.0 3-0-0 3x4 = 3-0-0 LOADING (psf) SPACING- 2-0-0 CSL DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.01 4-7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.17 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=64/Mechanical, 2=173/0-8-0, 4=37/Mechanical Max Horz 2=85(LC 10) Max Uplift 3=-54(LC 10), 2=-147(LC 10), 4=4(LC 10) Max Grav 3=70(LC 15), 2=173(LC 1), 4=50(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:9.4 PLATES GRIP MT20 244/190 Weight: 11 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purling. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 8=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint 2 and 4 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cen 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/l Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. . Satefylnrormation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply THE ROYALE T19781790 M11324 J4 MONO TRUSS 4 1 Job Reference o tional Chambers Truss; Inc., Fort Pierce, FL 1-0-0 3x4 = 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:33 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-7iDnHoc3lQepfMv9cu2Q8oLW4AtR4SNOSuUZOczXjGa 4-0-0 4-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.02 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 ' Rep Stress [nor YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 14 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc pudins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=89/Mechanical, 2=206/0-8-0, 4=50/Mechanical Max Horz 2=104(LC 10) Max Uplift 3=-79(LC 10), 2=-161(LC 10), 4=-8(LC 10) Max Grav 3=97(LC 15), 2=206(LC 1), 4=67(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 3, 161 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. Ullegan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall q� building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additlonal temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply THE ROYALE T19781791 M11324 J5 MONO TRUSS 11 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 1-0-0 3x4 = 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:33 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-7iDnHoc3lQepfMv9cu2Q8oLSAApH4SNOSuUZOczXjGa 5-0-0 1 Scale = 1:12.7 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) 0.06 4-7 >939 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.64 Vert(CT) -0.06 4-7 >964 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 17 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=115/Mechanical, 2=243/0-8-0, 4=63/Mechanical Max Horz 2=123(LC 10) Max Uplift 3=-104(LC 10), 2=-177(LC 10), 4=-9(LC 10) Max Grav 3=125(LC 15), 2=243(LC 1), 4=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; 13=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at joint 2 and 9 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd, Tampa FL 33610 Data: March 24,2020 WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Not building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply THE ROYALE T19781792 M11324 J6 MONO TRUSS 4 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:34 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-bvn9U8dhWjmgGWULAbZfg?BWa6ypvd9hYD6x2zXjGZ -1-0-0 6-0-0 1-0-0 6-0-0 3x4 = Scale=1:14.3 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) 0.11 4-7 >664 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.80 Vert(CT) -0.11 4-7 >652 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017lrP12014 Matrix -MP Weight: 20 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=142/Mechanical, 2=275/0-8-0, 4=70/Mechanical Max Horz 2=140(LC 10) Max Uplift 3=-129(LC 10), 2=-192(LC 10), 4=8(LC 10) Max Grav 3=155(LC 15), 2=276(LC 15), 4=100(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 ((b) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf, h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3, 192 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 41,111-7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply THE ROYALE T79781793 M11324 J8 MONO TRUSS 11 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:35 2020 Page 1 ID:kFvnsnOwY419Zh0 nM3lc6ylJ9g-35LXiUdJHlvXug3XkJ4uDDOp7_XMYMtJvCzgTVzXjGY 1-0-0 B-0-0 1-0-0 8-0-0 3x4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) -0.14 4-7 >676 360 TCDL 7.0 Lumber DOL 1.25 BC 0.47 Vert(CT) -0.30 4-7 >310 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Wind(LL) 0.26 4-7 >368 240 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS. (lb/size) 3=188/Mechanical, 2=348/0-8-0, 4=99/Mechanical Max Horz 2=178(LC 12) Max Uplift 3=-174(LC 12), 2=-226(LC 12), 4=13(LC 12) Max Grav 3=195(LC 17), 2=348(LC 1). 4=141(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:17.5 PLATES GRIP MT20 244/190 Weight: 26 lb Fr = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(1) 2-7-3 to 7-104 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3, 226 lb uplift at joint 2 and 13 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 tdiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING . Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall�- building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP/i Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply T1978179M11324 =tional) JA MONO TRUSS 2 1 Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:36 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-XHuvvgex2L1 OWgekHOc7mCiz5eNyVHp7S8siD?xzXjGX -1-M 2-4-3 1-0.0 2-4-3 3x4 = 2-4-3 Scale = 1:8.3 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) -0.00 7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 9 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-4-3 cc purlins. BOT CHORD 2x4 SO No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS. (lb/size) 3=45/Mechanical, 2=150/0-8-0, 4=28/Mechanical Max Horz 2=73(LC 10) Max Uplift 3=-37(LC 10), 2=139(LC 10), 4=-4(LC 7) Max Grav 3=50(LC 15), 2=150(LC 1), 4=37(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 37 lb uplift at joint 3, 139 lb uplift at joint 2 and 4 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parametersand READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIl•7473 rev. 1e10312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall pp /�� building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing IYIiTek* Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply THE ROYALE T19781795 M11324 JB MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 3x4 = 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:36 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-XHuvvgex2L1 OWgekHOc7mOzl ONm1Hp7S8siD7xzXjGX Scale = 1:12.5 5-5-11 S5-11 LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.38 Vert(LL) 0.10 4-7 >645 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.89 Vert(CT) -0.07 4-7 >898 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 19 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 5-0-0 oc bracing. REACTIONS. (Ib/size) 3=127/Mechanical, 2=269/0-8-0, 4=63/Mechanical Max Horz 2=114(LC 10) Max Uplift 3=-109(LC 10), 2=-206(LC 10), 4=-6(LC 10) Max Grav 3=127(LC 15), 2=269(LC 1), 4=90(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone;C-C for members and farces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 109 lb uplift at joint 3, 206 lb uplift at joint 2 and 6 lb uplift at joint 4. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not �® a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Oty Ply THE ROYALE T19781796 M11324 JC MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:37 2020 Page 1 I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-1USH6Afape9F7_Dwrk7MIeVGNnJvOGNbN WSmXNzXIGW 1-0-0 1-1-4 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 TCDL 7.0 Lumber DOL 1.25 BC 0.02 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10:0 Code FBC2017rrP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=1 1 /Mechanical, 2=119/0-8-0, 4=4/Mechanical Max Horz 2=50(LC 10) Max Uplift 3=-6(LC 7), 2=-138(LC 10) Max Grav 3=14(LC 15), 2=119(LC 1), 4=14(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:6.2 3x4 = 1-1-4 1-1-4 DEFL. in (too) I/deft Ud PLATES GRIP Vert(LL) -0.00 5 >999 360 MT20 244/190 Vert(CT) -0.00 5 >999 240 Horz(CT) 0.00 4 n/a n/a Weight: 5 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-1-4 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 6 lb uplift at joint 3 and 138 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not �® a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall�e building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply THE ROYALE T19781797 M11324 KJ5 MONO TRUSS 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:38 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-TgOgKWgCayH6I8c6PRebrr2OYBbJljcfbABK4pzXjGV -1-5.0 3-11-0 7-0-2 ' 1-5-0 3-11-0 3-1-2 2.83 12 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 TCDL 7.0 Lumber DOL 1.25 BC 0.26 BCLL 0.0 Rep Stress Incr NO WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS. (lb/size) 3=194/Mechanical, 2=233/0-11-5, 4=94/Mechanical Max Horz 2=109(LC 8) Max Uplift 3=-174(LC 8), 2=-191(LC 8) Max Grav 3=198(LC 13), 2=233(LC 1), 4=133(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:16.7 DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) 0.09 4-7 >923 360 MT20 244/190 Vert(CT) -0.15 4-7 >563 240 Horz(CT) 0.00 2 n/a n/a Weight: 23 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; 9=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3 and 191 lb uplift at joint 2. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase--1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-3=-95(F=-20, B=-20), 5=0(F=10, B=10)-to-4=-35(F=-8, B=8) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. URegan PE No.58126 MiTek USA, Inc. FL Cert 6634 69D4 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall my building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE T19781798 M11324 KJ8 MONO TRUSS 2 1 Job Reference a tional Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:39 2020 Page 1 ID:_knGCA6bx7j2Sy1 HDXFw7ye3KX-xsa2XsggKGPzNHNlz89gN3bblbyjU50uqqxtcGzXjGU 1-5 0 7-2-7 11-3-0 1 5 0 7-2-7 4-0-9 3x4 = 3x4 = 5 7-2-7 11-0-12 11-3-D 7-2-7 3-10-5 012 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.21 TCDL 7.0 Lumber DOL 1.25 BC 0.25 BCLL 0.0 Rep Stress Incr NO WB 0.35 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=90/Mechanical, 2=46510-11-5, 5=409/Mechanical Max Horz 2=178(LC 8) Max Uplift 4=-91(LC 8), 2=-332(LC 8), 5=-223(LC 8) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-875/541 BOT CHORD 2-6=535/842, 5-6=-535/842 WEBS 3-6=1/287, 3-5=-923/587 DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) 0.08 6-9 >999 360 MT20 244/190 Vert(CT) -0.10 6-9, >999 240 Horz(CT) 0.01 5 n/a n/a Weight: 44 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 9-10-15 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 91 lb uplift at joint 4, 332 Ill uplift at joint 2 and 223 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 61 lb up at 2-11-0, 38 lb down and 61 lb up at 2-11-0, 8 lb down and 106 lb up at 5-8-15, 8 lb down and 106 lb up at 5-8-15, and 42 lb down and 145lb up at 8-6-14, and 42 lb down and 145 lb up at 8-6-14 on top chord, and 31 lb up at 2-11-0, 31 lb up at 2-11-0. 11 lb down and 31 lb up at 5-8-15, 11 lb down and 31 lb up at 5-8-15, and 31 lb down and 14 lb up at 8-6-14, and 31 lb down and 14 lb up at 8-6-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pig Vert: 1-4=-54, 5-7=-20 Concentrated Loads (lb) Vert: 10=80(F=40, B=40)11=-5(F=-3, B=-3)12=-83(F=-42, B=-42)13=14(F=7, B=7)14=-21(F=11, B=-11)15=-50(F=-25, B=-25) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 ,& WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev, 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall p p� building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VI iTe k• Is always required for stability and to prevent collapse with possible personal Injury and property damage, For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, sea ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE T19781799 M11324 KJA MONO TRUSS �Qby 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL -1-2-9 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.21 TCDL 7.0 Lumber DOL 1.25 BC 0.17 BCLL 0.0 Rep Stress Incr NO WB 0.00 BCDL 10.0 Code FBC2017frPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS. (lb/size) 3=142/Mechanical, 2=181/0-9-11, 4=69/Mechanical Max Horz 2=97(LC 8) Max Uplift 3=-129(LC 8), 2=150(LC 8) Max Grav 3=145(LC 13), 2=181(LC 1), 4=104(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:39 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-xsa2XsggKGPzNHN Iz89gN3bbNbzyUAsuggxtcGzXjGU Scale = 1:13.6 DEFL. in (loc) I/defi Lid PLATES GRIP Vert(LL) 0.04 4-7 >999 360 MT20 2441190 Vert(CT) -0.07 4-7 >974 240 Horz(CT) 0.00 2 n/a n/a Weight: 20 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3 and 150 lb uplift at joint 2. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pig Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-3=-81(F=-14, B=-14), 5=0(F=10, B=10)-to-4=-30(F=-5, B=-5) This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE. ° Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not Nil a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE ROYALE T19781800 M11324 KJB MONO TRUSS 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Tue Mar 24 12:54:40 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-Q28QIChS5ZXc_RyV Wsg3wG7oh7KKDd623UgR8izxjGT -1-2-9 4-11-9 1-2-9 4-11-9 R,: IA = 1.11 7 3x4 = 4-11.9 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Vert(LL) -0.02 4-7 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC - 0.10 Vert(CT) -0.03 4-7 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 17 lb FT = 0% LUMBER- BRACING - TOP CHORD2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-11-9 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=95/Mechanical, 2=148/0-9-11, 4=46/Mechanical Max Horz 2=75(LC 8) Max Uplift 3=-84(LC 8), 2=-136(LC 8) Max Gram 3=95(LC 1), 2=148(LC 1), 4=77(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 84 lb uplift at joint 3 and 136 lb uplift at joint 2. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) This item has been Vert: 2=0(F=27, l3=27)-to-3=-67(F=-7, B=-7), 5=0(F=10, B=10}1to4=25(F=-2, B=2) electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cart 6634 0904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7479 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not HV a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Duality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type City Ply=ptional) T19 M11324 MV2 VALLEY 1 Chambers Truss, Inc., Fort Pierce, FL 2-0-0 3x4 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:41 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-uFioyXi4stfhcbXh4ZBITUg_ROhoy4MBl8Q_h8zXjGS 4.00 12 Scale = 1:6.1 LOADING (psf) SPACING- 2-0-0 CS]. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.04 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix-P Weight: 5 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=41/2-0-0, 2=30/2-0-0, 3=11/2-0-0 Max Horz 1=21(LC 10) Max Uplift 1=-20(LC 10), 2=-30(LC 10) Max Grav 1=42(LC 15), 2=32(LC 15), 3=22(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 2 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint 1 and 30 lb uplift at joint 2. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58128 MiTek USA, Inc. FL Cart 8634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component. not ��AA a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall -•Y�• building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Ply THE ROYALE T19781802 M11324 MV4 VALLEY �Qty 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 3x4 4-0-0 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:41 2020 Page 1 ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-uFioyXi4stfhcbXh4ZBITUgvHOfUy4MB18Q h8zXjGS 3x4 11 Scale = 1:9.4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.17 Vert(CT) n/a n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-P Weight: 12 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc puriins, BOT CHORD 2x4 SP No.3 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=109/4-0-0, 3=109/4-0-0 Max Horz 1=56(LC 10) Max Uplift 1=-54(LC 10), 3=-72(LC 10) Max Grav 1=112(LC 15). 3=117(LC 15) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. NOTES- 1•) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 1 and 72 lb uplift at joint 3. This item has been electronically signed and sealed by ORegan, Philip, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Philip J. O'Regan PE No.58126 MiTek USA, Inc. FL Cert 8634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - v.1Ity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall p qr building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Addiflonal temporary and permanent bracing 1 VI iTe k• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Symbols Numbering System ® General Safety Notes PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. Ole For 4 x 2 orientation, locate plates 0- 'lid' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. `Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSIITP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 2 3 TOP CHORDS Ct-2 C2-3 WEBS q,Q 4 0 of d a E— C7-e c6-7 C5-6 00 BOTTOM CHORDS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear lightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSIIrPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.