HomeMy WebLinkAboutTrussil
®=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
ALL. TRUSSES AI?E TO BE SET DON'T LIFT TRUSSES
AT 2"-O OI\CENTER WITH SPANS LONGER THAN
EXGEF- AS NOTED 30' BY THE PEAK. Ito
CONSULT BCSI
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
A IF MULTIPLE PLY. A
30' Span Iorless A&
T 53 degrees
or less
Tcc Line sPe� 'cpprcx.
REFER. TO B�S'
Tr,is must be set pis way c c e used
ti§s 's a ex mple, yow tress May not matcn-
Insst crone operotor setstross the way.
30, to 60' Span A
Spreader Bar
4ag *-- APproK 2/3 to._-'
Lme 1/2 of Span
REFER TO I
Jss .at be set this way if crane used.
This Is an example, truss may not match...
.Insist crane operator sets truss this. way.
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
Q are installed. Ai
AIR HAIVC�I-�R �0��
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
Carrying Girder
For Truss to Truss
Connections see
hanger/connector Nails must be as
shown. Guide tabs o
schedule in engineering Dome angle nails.
package.
Carried Truss
r rc
vor eevEiEo.
ARENOTSEVEs
ENGINEEPINC
EKGsR."IW
MZ J
a
2£S O
24'Oa. rHRu
CORNER JACKS V'116 L
ONLY . q.
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
SEAT PLATES BY CHAMBERS I
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 8'-1"
ABOVE FINISHED FLOOR
® ARRANGE WITH RAN OPERATOR I ADVANCE FOR A SPREADER BAR OF 118' - 24' IN LENGTH
Do not stand on trusses until they are braced per I & properly nailed to straps & hangers
heel=315/16" 15'-10"
PLUMB CUT END
2 x 4 Top Chord —
BEARING HEIGHT 8'-l"
TYPICAL END DETAIL
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED a RETURNED The legal description of the property where the trusses will be Installed is:
The undersigned ecknowledgea and agrees;
t: Trusses will be made In strict accordance with this truss placement diagram layout, which Is the sole euthodry, for detarmining. successful fabdcatton of the trusses.
. 2. All dlmensbns In this layout have been verified by 1Fie undersigned
.3. Unleab wnden nodes Is provided by cardfied mall to Chambere Truss wRhln ten (10)
days of delhrery the undersigned agrees that no beckchargee will be ellowed..ln the event such written nodes Is fumlehed Chambers Trues shell have three (3) bussjjneaa days in welch
to begin repalre required, or to substitute oNec trusses, at Chambers optlsn.
4. The undersigned acknowledges receipt of "BCSI 1-03' summery sheet by TPI 8 WiCA.
deIs llveryuChambereJTNas heat the aoele authority to detennmloathe au� bllRy of the jobtalte iefor
portion of the Job she for delivery, Chambere as will be responsible for dump delivery only.
The buyer Is responsible for addldona(del Nsrr expenses tl Chambers Truss has to redelNer
I because Job aria Is riot proparod for delivery or buyer Is not prepared for delivery of trusses,
Buyer Is reaponalble to Chambers TNec for towing costa due to site conditions,
S. Price as shown Iq paregraph 7 below Is eubJeq to change If any changes are. made In
this layout. A $50 per hour fee for revisions may be charged by Chambers Truss. '
7: This Is a PURCHASE ORDER to Chambers, Trues of the sum agreed to or M na:.
agreement a reasonable price, Involee will be made on delivery and paid within terms o/ net
on delivery. Invoice may, be made at scheduled date of delivery tl buyer cannot eccepT
delivery of fabricated trusses. The undersigned agrees to pay Chambere.TNss reasonable
ettomey's tee for eolleglbne In event of payment not timely made. 1-t2 °%per month servJce '
charys will be added for all sumo not paidwithinteens.
B. Signature or Initials anywhere on this sheet constitutes agreement to all tense herein.
Ban consideration at Chambers Truss extending credit for this material the undersigned
uncondltlonelly guarantees payment when due of any and all Indebtedness owed to
Chambers TNsa by any eerily receiving material and Na undersigned agrees to pay such
Indebtedness Inqu•Ing attorneys tees, tl default In payment for material be made by the
regpleM. `_
-te. In the avant o1 any 1Rlgatlon concerning this agreement, the kema furnished hereunder
or payments referred to herein, the, parties ogres that the sole venue for any such adios will f
be Se1M l.uge County, Plonde.
11. Design respons1b111Gea are per 'National Standard And Recommended Guidelines On
Raeponslbllltlea For Construction Using Metal Plate Connected Wood Trusses
ANSI/rPIM/rCA 4 - 20a2"
DATED .
SIGNED ,
POR__.. TfRE
Aspre.'tde+' barmayba required Per'"SCSI 1-03" th prevent Iry'ta'y8 damage.
Multiple Iply trusses must be fastened together per engineering
before they are set; failure to do so can result In roof collapse.
Temporary and permanent bracing are required and ran save life
and properly and Is the responslblllty of the truss erector.
'Study the contents of the Information packet Included on delivery
before setting trusses. `
Trt�ses must be set and braced par design to prevent injury �, l�ytage,
Trusses must be sat plumb and square
Do not set bunks or stack of plywood, roofing material or any
-other concentrated loads on trusses, this can cause collapse.
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
Cl�]AMBERS TRUSS INC
3105 Oleander Avenue
Fort Pierce; Florida 34982-6423
800-551-5932
Fort Pierce 772r485-2012 Fax 772-465-8711
Vero Beach 772569.2012 Stuart 772-288J302 '
,.°-� sera.,. ruwunroerorlsST.nM
0 The Architect's or Architect's reprnsentafive's.
shop drawing approval is NOTa,
"double check" of the contraetpn
The contractor shall remain respolIhsible
for checking field measuremant g. and
.other construction criteria. Architect's
approval covers general roof shape,
review of truss strapping, an loading on
' structure from gravity and uplift loads and
their. res 'tivelocati ns j
Approved � `"D
,Date:
Braden ii BradenA.1.A. P.A.-
92.0/93.2 MITEK 42
DESIGN CRITERIA
County SAINT LUCIE
Building Department ST LUCIE COUNTY
+ Wind Design Criteria ASCE 7-2010
-� Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10
— w Roofing Material Metal Roof
y 2 Loading in PSF Roof R.D.L..
fr'I ° Top Chord Live 20
o � c � Top Chord Dead 7 4.2
L N Bottom Chord Live 10 Non -Concurrent
w �
Bottom Chord Dead 10 3
d � TOTAL Load 37 7.2
—' Duration Factor 1.25
� J Wind Speed 165mph
3 � �✓` Top Chord C.B. Sheeting by builder.
U
Bottom Chord C.B. Sheeting by builder.
Highest Mean Height 12'-0"
.Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017
R.D.L.=Restrainin Dead Load C.B.=Continuous Bracing
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Buildin Desi per and/or Engineer of Record.
�/ Chambers Truss Inc. Drawing Name: M11324
L� Scale: 1 /4 = 1'
L 83 total trusses, 27 different trusses.
MI 4: SAE AGAD: SAE Reviewed
Da1ie:07l19/12 Revised: 03/21118
�B
F('(-� Revised 3105/2fJ20
WYNNE BUILDING CRP.
DESGRIPTI®N: 7lo�atl
GARAGE RIGHT CODE COIi � NC:RI�YALE
OJT. �-U aC�I/E C NT PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
27 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT 1324 � oat
Gl
Al
Al
Al
Al
04
(10
GRB
,
16
N
<
f0
an
m
m
m
m
m
ap
m
a0
m
a7
fD
7
N
� �
r
i.V J2
N
J2
O
J6
III
I
A2
I �
�
I
s
I
Al
N
1� I IN
13'-72"
Al
I
I
A
I
I :
Al
I
Al
A
A
S
�Wc.)
� V O
A
WmQ
Z
zl
q
0
N
r�
T SETBACK BOSTON HIP TRJSS
I
� ' I
ill-
v rJ3
.—
B I
I I
I
�
I
a i I
35'
REVI
MiTek` ;
RE: ml1324 MiTek USA, Inc.
THE ROYALE 6904 Parke East Blvd.
Tampa, FL 33610-4115
Site Information:
Customer: WYNNE BUILDING CORPORATION Project Name: ml 1324
Lot/Block:. Model: ROYALE
Address: UNKNOWN Subdivision:
City: ST LUCIE State: FL
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 165 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 27 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal#
Truss Name
Date
No.
Seal# Truss Name Date
1
T19781776
A
4/22/2020
21
T19781796 JC 4/22/2020
2
T19781777
Al
4/22/2020
22
T19781797 KJ5 4/22/2020
3
T19781778
A2
4/22/2020
23
T19781798 KJ8 4/22/2020
4
T19781779
A3
4/22/2020
24
T19781799 KJA 4/22/2020
5
T19781780
A4
4/22/2020
25
T19781800 KJB 4/22/2020
6
T19781781
A6
4/22/2020
26
T19781801 MV2 4/22/2020
7
T1978178
B
4/22/2020
27
T1MV 0
9
8
T19781783
BHA
4/22/2020
1 �
9
T19781784
GRA
4/22/2020
10
T19781785
GRB
4/22/2020
11
12
T19781786
T19781787
GRC
J1
4/22/2020
4/22/2020
REVIEWED FOR
13
T19781788
J2
4/22/2020
COMPLIANCE
14
T19781789
J3
4/22/2020
CODE
ST. LUCIE COUNTY
16
T197817911
J5
4/22/2020
17
T19781792
J6
4/22/2020
S®CC
18
T19781793
J8
4/22/2020
19
T19781794
JA
4/22/2020
20
T19781795
JB
4/22/2020
This item has been electronically signed and sealed by ORegan, Philip using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc under my direct supervision ,,����jf1111j������
based on the parameters provided by Chambers Truss. ��� �Q •
Truss Design Engineer's Name: ORegan, Philip ��%% N . 0 E N sF�y2
My license renewal date for the state of Florida is February 28, 2021.
Florida COA: 6634 No 5 8126
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verity applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
T
-33:. STATE OF •:��/
Al
11111
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610 April 22, 2020
1 of 1 ORegan, Philip
w
Job
Truss
Truss Type
Qty
Ply
THE ROYALE
T19781776
M11324
A
COMMON
10
1
R
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:64:17 2020 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-bdFkwKP1 W Vd5kvh4gXmgUQgkzjKtK4bfmPcjgXzXjGq
1-0-0 8-4-0 12-11-0 17 6-0 22-1-0 26-8-0 35-0-0 6-0
-0-0 8-4-0 4-7-0 4-7-0 4-7-0 4 7-0 8-4-0 0-0
4.00 12
4x5 =
Scale=1:59.3
17 '" 15 `" `" 14 '" 12
46 — 2x3 II 5x6 WB = 3x8 = 2x3 II 4x5 =
3x8 =
5x6 WB =
84-0
12-11-0
22-1-0
26-8.0
35.0-0
8�
4-0 7-0
9-2-0
4 7-0
8-4-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
Well
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.59
Vert(LL)
0.33 14-15
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.68
Vert(CT)
-0.64 14-15
>652
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.63
Horz(CT)
0.13 10
n/a
n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MS
Weight: 169 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=1399/0-8-0, 10=1399/0-8-0
Max Horz 2=-223(LC 8)
Max Uplift 2=-775(LC 10), 10=-775(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=3404/2226, 3-5=2807/1885, 5-6=-2801/1990, 6-7=-2801/1990, 7-9=-2807/1885,
9-10=3404/2226
BOT CHORD 2-17=1946/3218, 15-17=-1946/3218,'14-15=-1116/2053, 12-14=-1946/3188,
10-12=-1946/3188
WEBS 6-14=-598/1034, 7-14=-252/246, 9-14=-702/541, 6-15=-598/1035, 5-15=-253/246,
3-15=701 /541
Structural wood sheathing directly applied or 3-1-13 oc purlins.
Rigid ceiling directly applied or 4-10-7 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Exterlor(2)12-8-6
to 17-6-0, Interior(1) 22-1-0 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at
joint 10.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-B9 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T19781777
M11324
Al
SPECIAL
�Qty
9
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.13u s Mar 11 LU18 Mi l ek inoustnes, mc. i ue Mar z4 iz:b4:ld 2u2Q rage 1
ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-3gp67gQfHplyL3GGEEHvldDr47c?3X1o?3LGM 7-XjGp
1-0-0 7-8-0 13-7-8 17 6-0 23-11-12 26-9-10 35-M 6-0
-0-0 7.8-0 5-11.8 3-10-8 6-5-12 2-9-14 8-2-6 1-0-0
Scale = 1:60.3
3x5 =
5x8 MT18HS =
4.00 12
14 13
2x3 11 5x12 =
2.00 12
LOADING (psi)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC20171TP12014
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3 *Except*
6-12: 2x4 SP M 30
OTHERS
2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 10=1349/0-8-0
Max Horz 2=-223(LC 8)
Max Uplift 2=-825(LC 10), 10=-825(LC 10)
35-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES
TC 0.89
Vert(LL) 0.80
12 >525 360
MT20
BC 0.94
Vert(CT) -1.39
12-13 >302 240
MT18HS
WB 0.62
Horz(CT) 0.37
10 n/a n/a
Matrix -MS
Weight: 159 lb
BRACING -
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD
Rigid ceiling directly applied.
WEBS
1 Row at midpt 6-12
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3309/2433, 3-5=2581/2012, 5-6=-2548/2113, 6-7=-5337/4002, 7-9=-5302/3868,
9-10=-5702/4143
BOT CHORD 2-14=-2151/3113, 13-14=-2151/3113, 12-13=-1450/2202, 10712=-3809/5431
WEBS 3-14=0/265, 3-13=-B13/590, 5-13=-269/317, 6-13=-317/567, 6-12=-2362/338B,
7-12=-298/368,9-12=-405/352
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
Il; Exp C; Encl., GCpj=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Exterior(2) 12-8-6
to 17-6-0, Interior(1) 22-3-10 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = I O.Opsf.
6) Bearing atjoint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 10.
3x12 Zz
GRIP
244/190
244/190
FT = 0%
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addtional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781778
PM11324
A2
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Tue Mar 24 12:54:19 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-XONULORH26uozDrSoy0
8Zri3jXxjoyGyEj5gvQzXjGo
1-0- 8-0-1 13-7-8 16-0-0 19-0-0 23-11-12 26-9-9 35-0-0 6-0-
ON 8-0-1 5 7-7 2-4-8 3-M 4-11-12 2-9-13 8-2-7 -0-0
Scale = 1:62.3
4.00 12
5x6 = 4x4 =
3x8
5x10 7 5x6
34 8g
22 23
12
2 10 11 4
13 6x10 MT18HS = [ '-
14 3x10
15
3x5
2x3 II 5x6 = 3x12
= 2.00 12
9-0-0 23-11-12
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.70
Vert(LL) 0.75 12 >559 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.98
Vert(CT) -1.02 12-21 >412 240
MT18HS 244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.75
Horz(CT) 0.37 10 n/a n/a
BCDL 10.0
Code FBC2017rTP12014
Matrix -MS
Weight: 160 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-4-8 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied
or 2-2-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at midpt
7-13
REACTIONS. (lb/size) 2=1349/0-8-0, 10=134910-8-0
Max Horz 2=-205(LC 8)
Max Uplift 2=-825(LC 10), 10=-825(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3315/2113, 3-5=-2515/1641, 5-6=-2524/1699, 6-7=-2672/1734, 7-9=-5246/3199,
9-10=5687/3567
BOT CHORD 2-15=1849/3111, 14-15=-1849/3111. 13-14=1217/2314, 12-13=-2804/5025,
10-12=-3257/5414
WEBS 3-15=0/300, 3-14=-954/692, 5-13=-206/561, 6-13=-357/632, 7-13=-2796/1678,
7-12=1082/1957, 9-12=-479/463
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6
to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members.
electronically signed and
7) Bearing at joint(s) 10 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify
sealed by ORegan, Philip, PE
capacity of bearing surface.
using a Digital Signature.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
printed copies of this
P
joint 10.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE ROYALE
T19781779
M11324
A3
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:20 2020 Page 1
ID: _kfiGCA6bx7j2Syl HDXFw7ye3KX-7CxsYMSvpQOfbNQfLfJN62IEjxHyXPZ5SNgNRszXjGn
�1-0-0 8-0-1 14-M 21-0-0 1-1 1-1
, 26-9-10 35-0-0 3s-o-a
-0-0 8-0-1 5-11-15 7-0-0 2.11-12 2-9-14 8-2-6-0-0'
3x5 =
5x6 =
4x6 =
Ann ri—q- 4 b 'WA
13 "
2x3 11 5x6 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017frP12014
2.00 12
CSI.
DEFL.
in (loc)
Udefl
Ud
TC 0.69
Vert(LL)
0.72 10
>582
360
BC 0.98
Vert(CT)
-0.98 10-19
>427
240
WB 0.74
Horz(CT)
0.35 8
n/a
n/a
Matrix -MS
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 8=1349/0-8-0
Max Horz 2=-181(LC 8)
Max Uplift 2=-825(LC 10), 8=-825(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=3286/2122, 3-4=2556/1711, 4-5=-3161/2095, 5-6=-3304/2150, 6-7=-5214/3232,
7-8=5695/3643
BOT CHORD 2-13=1853/3079, 12-13=-1853/3079, 11-12=-1338/2410, 10-11=-2826/4982,
8-10=-3331/5422
WEBS 3-13=0/293, 3-12=-854/595, 4-11 =-480/959, 5-11 =-360/724, 6-11 =-2280/1355,
6-1 0=1 118/1934, 7-1 0=-530/51 5
Scale = 1:61.3
3x12
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight: 158 lb FT = 0%
Structural wood sheathing directly applied or 2-5-0 oc pudins.
Rigid ceiling directly applied or 2-2-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Extedor(2) 31-2-6
to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise Indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing atjoint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 8.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 8634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T79781780
M11324
A4
SPECIAL
�Qty
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:22 2020 Page 1
ID:—kfiGCA6bx7j2Syl HDXFw7ye3KX-xb2ci2T9L1 GNggal T4MrBTNaQkzc?IfOwhJU WIzXjGI
1-0-0 6-5-8 12-0-0 17-8-4 23-0-0 2 11-1 26.9-9 35-0-0 6-0-
-0-0 66 5-8 5-6-8 5-8-0 5-3-12 0-11-1 2%-13 8-2-7 -0-0
4.00 12
3x6 =
5x6 = 3x4 =
14 13 3x4
3x4 = 5x6 =
2.00 12
5x8 =2x3 II
6 7
Scale = 1:61.3
3x12 -
8-8-2 13.7-8
17-6-0
23-11-12
35-0-0
8-8-2 4-11-6
3-10-8
6-5-12
11-0-4
Plate Offsets (X,Y)—
[2:0-0-6,Edge], [6:0-4-0,0-2-3], [9:0-1-15,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc)
I/deft
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.67
Vert(LL) 0.73 11-12
>572
360
MT20
2441190
TCDL 7.0
Lumber DOL 1.25
BC
0.96
Vert(CT) -0.98 11-20
>429
240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB
0.77
Horz(CT) 0.36 9
n/a
n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MS
Weight: 160 lb
FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-8-0
Max Horz 2=157(LC 9)
Max Uplift 2=-825(LC 10), 9=-825(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3367/2256, 3-4=-3093/2069, 4-5=-2645/1853, 5-6=-3425/2347, 6-7=-5165/3301,
7-8=-5219/3301, 8-9=5704/3714
BOT CHORD 2-14=2000/3170, 13-14=-1488/2537, 12-13=-2065/3480, 11-12=-2440/4196,
9-11=-3399/5431
WEBS 3-14=-429/415, 4-14=-323/584, 4-13=-142/386, 5-13=-1125/697, 5-12=-141/467,
6-12=861/437, 6-11 =-1 145/2016, 8-11=-542/518
Structural wood sheathing directly applied or 2-5-6 oc purlins.
Rigid ceiling directly applied or 2-2-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6
to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing atjoint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 Ito uplift at
joint 9.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
69D4 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED M1TEK REFERENCE PAGE MI1-7473 rev. 10/03/2015 BEFORE USE.
�—
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek"
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE ROYALE
T79781781
M11324
A6
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:23 2020 Page 1
ID:_kriGCA6bx7j2Syl HDXFw7ye3KX-Pnc?AOUo6LOESg9E1 nt4khwkW8Mmkt1Y9L312BzXjGk
�1-0-0 6-7-15 !I--'
0-0-0 13-8-0 21-4-0 25-0-0 28 4-0-1 1 `35-0-0
0-0 6-7-15 3 4-1 3.8.0 7-8-0 N 3--1 6-7-15 -0-0
�1
6
4x5 =
5x8 = 24 .II 2x3 II 5x8 =
4.00 12
4 23 24 5 25 26 6 27 28 7
16 15 14 13 12 11
3x4 = 4x6 = 3x4 =
3x4 = 4x6 = 3x4 =
10-M 1311 21-4-0 25-0-0 35-0-0
' 10-0-0 3-6-0 7.8-0 3-8-0 10-0-0
Plate Offsets (X,Y)— [2:0-1-14,Edge], [4:0-5-4,0-2-8], [7:0-5-4,0-2-8], [9:0-1-14,Edge]
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.71
TCDL
7.0
Lumber DOL
1.25
BC 0.71
BCLL
0.0
Rep Stress Incr
YES
WB 0.31
BCDL
10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1118/0-8-0, 14=379/0-8-0, 9=1201/0-8-0
Max Hors 2=-133(LC 8)
Max Uplift 2=-692(LC 10), 14=-219(LC 10), 9=-739(LC 10)
Max Grav 2=1118(LC 1),14=454(LC 19). 9=1 206(LC 20)
Scale = 1:60.3
4x5 =
DEFL.
in (too)
I/deft
Ud
PLATES GRIP
Vert(LL)
0.6011-13
>424
360
MT20 244/190
Vert(CT)
-0.78 13
>328
240
Horz(CT)
0.11 9
n/a
n/a
Weight: 153 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins.
BOT CHORD Rigid ceiling directly applied or 4-6-3 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2600/2341, 34=-2215/1960, 4-5=-2527/2290, 5-6=-2527/2290, 6-7=-2527/2290,
7-8=-2531/2224,8-9=-2880/2572
BOT CHORD 2-16=-2074/2444, 14-16=-1569/2065, 13-14=-1968/2527, 11-13=-1833/2382,
9-11=-2290/2707
WEBS 3-16=-495/599, 4-16=-206/347, 4-14=-541/820, 5-14=-526/591, 6-13=-234/311,
7-13=1821282, 7-11 =-355/492, 8-11 =-444/551
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 16-9-7, Interior(1) 16-9-7 to 18-2-9, Exterior(2) 18-2-9
to 25-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 692 lb uplift at joint 2, 219 lb uplift at
joint 14 and 739 lb uplift at joint 9.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verfly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIF7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall �..r.
iTek-
It
building design. Bracing Indicated is to prevent buckling of individual truss web andfor chord members only. AddiOonal temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the iVl
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPIf quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE ROYALE
T79781782
M11324
B
COMMON
3
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:24 2020 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-uzANOjVQtfW53JQaVOJGuT?gYo2TNIhN?oaadzXjGj
-1-0-0 6-11-0 13-10-0
1�+ 6-11-0 6-11-0
Scale: 1/2"=1'
46 =
1
1A
5
2x3 11
0
3x4 =
3x4 =
6-11-0
13-10-0
6-11-0
6-11-0
Plate Offsets (X,Y)—
[2:0-2-10 Edge] [4:0-2-10,Edge)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25 -
TC 0.37
Vert(LL) 0.10
5-8 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.33
Vert(CT) -0.13
5-8 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.12
Horz(CT) 0.01
4 n/a n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MS
Weight: 47 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 7-7-1 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=510/0-8-0, 2=568/0-8-0
Max Horz 2=93(LC 9)
Max Uplift 4=-292(LC 10). 2=-377(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-967/954, 3-4=-966/952
BOT CHORD 2-5=785/883, 4-5=-785/883
WEBS 3-5=84/315
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45tt; L=50ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 292 lb uplift at joint 4 and 377 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. VRegan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
® WARNING - Verlly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall p qr It
building design. Bracing Indicated Is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing IYI iT®k-
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-69 and BCS/ Building Component 6904 Parke East Blvd.
Safetyinformadon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE ROYALE
T19781783
M11324
131-17
BOSTON HIP
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:25 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-MAklb3W2dyeyh8lc8CvYp6?4vy5bCkwgcfY864zXjGi
15-" 21-6-0
1-0-0 7-0-0 9.6-0 11.6-0 13-M 1 -017-6-0 19-6-0 21-0-0 23-6-0 25-6.0 28.0-0 35-0-0
-0.0 7-0-0 2-6-0 2-0-0 2-0-0 016 1-6-0 2-0-0 2-0-0 1-6.00-6 2-0-0 2-0-0 2.6-0 7-0-0 -0-0
Scale = 1:62.6
35
3x5 =
4.00 12 5x6 =
— 33
46 = 3x8 =
12 14 16
32 -'
3x4 = 4x6 =
30
3x6 =
7-0-0 14-0-0
21-0-0 28-0-0 35-0-0
7-0-0 7-0-0
7-007-0-0 7-0-0
Plate Offsets (X,Y)—
[2:0-1-2,Edge), [28:0-0-2,Edge)
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in (loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.72
Vert(LL) 0.51 32-33 >826 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.56
Vert(CT) -0.67 32-33 >628 240
BCLL 0.0
Rep Stress Incr YES
WB 0.48
Horz(CT) 0.14 28 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MS
Weight: 208 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 3-8-6 oc pudins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 4-6-1 oc bracing.
WEBS 2x4 SP No.3
JOINTS 1 Brace at Jt(s): 11, 18, 15, 7, 23
REACTIONS. (lb/size) 2=1349/0-8-0, 28=1349/0-8-0
TOP CHORD MUST BE BRACED BY END JACKS,
Max Horz 2=223(LC 8)
ROOF DIAPHRAGM, OR PROPERLY CONNECTED
Max Uplift 2=-825(LC 10), 28=-825(LC 10)
PURLINS AS SPECIFIED.
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3392/2640, 3-4=1213/956, 4-8=-1157/946, 8-9=-1145/979, 9-12=-112211028,
12-14=-1125/1090,14-16=-1124/1089,16-19=-1121/1028,19-22=-1145/979,
22-26=-1157/946, 26-27=-1214/956, 27-28=-3393/2641, 3-5=-2373/2046, 5-7=-2376/2050,
7-10=-2376/2050, 10-11=-2376/2050, 11-13=-2376/2050, 13-15=-2376/2050,
15-17=-2376/2050, 17-18=-2376/2050, 18-20=-2368/2046, 20-23=-2368/2046,
23-25=-2368/2046,25-27=-2364/2041
BOT CHORD 2-35=-2358/3190, 33-35=-2360/3166, 32-33=-2652/3448, 30-32=-2361/3167,
28-30=-2358/3191
WEBS 3-35=0/284, 27-30=0/285, 3-33=-317/378, 18-33=-466/474, 27-32=-312/353,
14-15=405/437
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10: Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 10-8-9, Exterior(2)10-8-9
This item has been
to 17-6-0, InteNor(1) 24-3-7 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
electronically signed and
3) Provide adequate drainage to prevent water ponding.
Sealed by ORegan, Philip, PE
4) All plates are 2x3 MT20 unless otherwise indicated.
Using a Digital Signature.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
Printed copies of this
6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
document are not Considered
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signed and sealed and the
joint28.
signature must be verified
8) Graphical purlin representation does not depict the size or the orientation of the purin along the top and/or bottom chord.
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cart 8634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall q�
building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing WOW
iTe k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE ROYALE
T19781784
M11324
GRA
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:27 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-1YsV01X19augwRS7GdxOuX5Zrlrvglw73z1 FByzxGg
1 0 0 4-1-8 5-71 8.2-13 9-8-8 13-10-0 14-10-0
1-0-0 4-1-8 1-5 11 2-7-9 1-5 11 4-1-8 1 0 0
Scale=1:26.6
2.37 12
4x4 = 44 =
4x10 4x10
19 4 20 21 5 22 6 zz
0
3x4 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017frP12014
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3
REACTIONS.
(lb/size) 2=77010-8-0, 7=770/0-8-0
Max Horz 2=-65(LC 6)
Max Uplift 2=-523(LC 8), 7=523(LC 8)
Max Grav 2=787(LC 17), 7=787(LC 18)
2x3 II 3x4 = 3x4 = 2x3 II
CSI.
DEFL.
in
(loc)
I/dell
Lid
TC 0.18
Vert(LL)
0.08
11
>999
360
BC 0.32
Vert(CT)
-0.10
10
>999
240
WB 0.06
Horz(CT)
0.03
7
n/a
n/a
Matrix -MS
3x4 =
PLATES GRIP
MT20 244/190
Weight: 58 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-4-7 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-0-4 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=1798/1192, 3-4=1761/1197, 4-5=-1724/1169, 5-6=1761/1190, 6-7=-1798/1137
BOT CHORD 2-12=-1083/1685,11-12=-1082/1692,10-11=-1112/1724,9-10=-1024/1692,
7-9=1028/1685
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate gdp DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 523 lb uplift at joint 2 and 523 lb uplift at
joint 7.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 63 lb down and 114 lb up at
4-1-8, 85 lb down and 124 lb up at 5-0-0, 113 lb down and 146 lb up at 5-7-3, 60 lb down and 129 lb up at 5-11-0, 60 lb down and
129 lb up at 7-11-0, 113 Ito down and 146 lb up at 8-2-13, and 85 lb down and 124 lb up at 8-10-0, and 63 lb down and 139 lb up at
9-8-8 on top chord, and 6 lb down and 7 lb up at 4-1-8, 18 lb down and 15 lb up at 5-0-0, 33 lb down at 5-7-3, 39 lb down at 5-11-0
, 39 lb down at 7-11-0, 33 lb down at 8-2-13, and 18 lb down and 15 lb up at 8-10-0, and 6 lb down and 7 lb up at 9-8-8 on bottom
chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-4=-54, 4-5=-54, 5-6=-54, 6-8=-54, 13-16=-20
Concentrated Loads (lb)
Vert: 3=7(B) 4=-64(B) 5=-64(B) 6=7(B) 12=6(121) 11=35(B) 10=-35(B) 9=-6(B) 19=-28(B) 20=60(B) 21=-60(B) 22=-28(B)
23=18(B) 24=-18(B)
m
I"
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - VeNly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 1`010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS87P/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T19781785
M11324
GRB
SPECIAL
�Qty
1
1
Job Reference (optional)
unamoefs I fuss, Inc., ron rlerce, rL o. ISU s Mar -,-, LUI0 IVII1 ex Inuustnes, inc. i ue ,Vlar L9 Ic[09:co cucu rdye r
• ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-mlQuE5YwwtOXYbl BpLSFRkdg49ACP4oHldmojOzXjGf
0
5-0-0 10 3-0 15 6-0 21.6.0 26-2-0 28-1-0 35 0-0 36-0 q
0-0 5-0-0 5.3-0 5.3-0 60
-0 4 8 0 1-11-0 6 11-0
Scale=1:62.4
2x3 11
4x4 =
4.00 12
4x8 =
3x4 =
3x6
=
2x3 II
4x4 =
9
3
25 26
4 27
28 29 5
630 31 32
733 34 35
a
,n1 2
n
10 11 N
}j��J
0EE0
I-.
18
36 37
17 38
16 39
42
14 4313
12
3x4 =
2x3 II
3x4 =
3x6 =
5x1 _4041
3x4 =3x6 =
30
30 =
5-0-0
10-3-0
15-6-0
21-6-0
28-1-0
35-0-0
5 0-0
5-3-0
6-0-0
6-7-0
6-11-0
Plate Offsets (X,Y)—
[3:0-5-4,0-2-01
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/deft
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.41
Vert(LL)
0.11 17-18 >999
360
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.38
Vert(CT)
-0.14 17-18 >999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.53
Horz(CT)
0.03 10 n/a
n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MS
Weight: 146 lb
FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-4-6 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at micipt 4-15
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=96(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-536(LC 8), 15=-846(LC 8), 14=-555(LC 8), 10=-314(LC
8) 1
Max Grav All reactions 250 lb or less atjoint(s) except 2=787(LC 17), 15=1322(LC 1), 14=927(LC 1), 10=506(LC
14)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-1773/1106, 3-4=-1406/944, 4-6=-304/595, 6-7=-304/595, 7-8=-304/595,
8-9=-702/344, 9-10=-719/323
BOT CHORD 2-18=-96211659, 17-18=-958/1675, 15-17=-843/1406, 14-15=-595/429, 12-14=-158/622,
10-12=-196/636
WEBS 3-18=0/331, 3-17=-297/158, 4-17=0/362, 4-15=2076/1313, 6-15=505/480,
7-14=-431/408, 8-14=-10631625. 8-12=115/265
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 536 lb uplift at joint 2, 846 lb uplift at
joint 15, 555lb uplift at joint 14 and 314 lb uplift at joint 10.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 257 lb down and 341 lb up at
5-0-0. 100 lb down and 129 lb up at 7-0-12, 100 lb down and 129 lb up at 9-0-12, 100 lb down and 129 lb up at 11-0-12, 100 lb
down and 129 lb up at 13-0-12, 100 lb down and 129 lb up at 15-0-12, 100 lb down and 129 lb up at 17-0-12, and 100 lb down and
129 lb up at 19-0-12, and 100 lb down and 129 Ib up at 21-1-4 on top chord, and 83 lb down at 5-0-0, 39 lb down at 7-0-12, 39 lb
down at 9-0-12, 39 lb down at 11-0-12, 39 lb down at 13-0-12, 39 lb down at 15-0-12, 39 lb down at 17-0-12, and 39 lb down at
19-0-12, and 39 lb down at 21-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of
others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not ��®®
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing WOW
is always required for stability and to prevent collapse with.possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/f Quality Criteria, DSB49 and SCSI Building Component 6904 Parke East Blvd.
Safety lnformallon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa. FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781785
M11324
GRB
SPECIAL
1
1
Job Reference (optional)
I Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:28 2020 Page 2
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-mlQuE5YwwtOXYbl BpLSFRkdg49ACP4oHldmojOzXjGf
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-8=-54, 8-9=-54, 9-11=-54, 19-22=-20
Concentrated Loads (lb)
Vert: 3=-160(F) 18=A5(F) 25=-60(F) 26=-60(F) 27=-60(F) 29=-60(F) 30=-60(F) 31=-60(F) 32=-60(F) 33=60(F) 36=-13(F) 37=-13(F) 38=-13(F) 39=13(F) 40=-13(F)
41=-13(F) 42=-13(F)43=-13(F)
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II-7473 rev. f010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Iva I'
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek♦
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPN Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE ROYALE
T19781786
M11324
GRC
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:30 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-i7XeenZBSVGFnvBaxlVjW9jxmzm3tvGamxFvoHz)gGd
1-0-0 8-M 13-8-0 17-6-0 21-4-0 27-0-0 35-0-0 6-0
0-0 8-M 5-8-0 3-10-0 3-10-0 5 8 0 M-0 -0-0
Scale=1:60.3
5x8 MT18HS = 5x8 MT18HS =
4.00 12 2x3 11 3x8 = 3x6 = 2x3 II
3 23 24 25 426 27 285 6 729 30 31 32 8
16 33 15 14 34 35 36 37 13 38 12 39 11
3x5 = 2x3 II 3x6 = 6x10 = 6x10 = 3x6 = 2x3 II 3x5 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017/TPI2014
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3 *Except*
4-14,7-13: 2x6 SP No.2
CSI.
DEFL.
in (loc) I/defl Lid
PLATES
GRIP
TC 0.71
Vert(LL)
0.2211-22 >999 360
MT20
244/190
BC 0.67
Vert(CT) -0.31 13-14 >830 240
MT18HS
244/190
WB 0.79
Horz(CT)
0.05 9 n/a n/a
Matrix -MS
Weight: 157 lb
FT = 0%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-5-6 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 5-9-3 oc bracing.
WEBS
1 Row at midpt 3-14. 5-14
REACTIONS. (lb/size) 2=412/0-8-0, 14=3582/0-8-0, 9=1192/0-8-0
Max Horz 2=-109(LC 6)
Max Uplift 2=-299(LC 8), 14=-2133(LC 8), 9=764(LC 8)
Max Grant 2=423(LC 17), 14=3582(LC 1), 9=1194(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=377/225, 3-4=-1093/1954, 4-5=-109311954, 5-7=-1943/1220, 7-8=-1943/1220,
8-9=-2776/1671
BOT CHORD 2-16=-154/317,14-16=-160/350,11-13=-1475/2624,9-11=-1464/2591
WEBS 3-16=-200/679, 3-14=-2514/1528, 4-14=-641/586, 5-14=-2674/1707, 5-13=-1124/2080.
7-13=-592/548, 8-13=-760/483, 8-11=-201/684
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 299 lb uplift at joint 2, 2133 lb uplift at
joint 14 and 764 lb uplift at joint 9.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 182 lb down and 312 lb up at
8-0-0. 107 lb down and 173 lb up at 10-0-12, 107 lb down and 173 lb up at 12-0-12, 107 lb down and 173 lb up at 14-0-12, 107 lb
down and 173 lb up at 16-0-12, 107 lb down and 173 lb up at 16-114, 107 lb down and 173 lb up at 18-11-4, 107 lb down and 173
lb up at 20-11-4, 107 lb down and 173 lb up at 22-11-4, and 107 lb down and 173 lb up at 24-11-4, and 182 lb down and 312 lb up
at 27-0-0 on top chord, and 411 lb down and 242 lb up at 8-0-0, 79 lb down and 1 lb up at 10-0-12, 79 lb down and 1 lb up at
12-0-12, 79 lb down and 1 lb up at 14-0-12, 79 lb down and 1 lb up at 16-0-12, 79 lb down and 1 lb up at 16-11-4, 79 lb down and
1 lb up at 18-11-4, 79 lb down and 1 lb up at 20-11-4, 79 lb down and 1 lb up at 22-11-4, and 79 lb down and 1 lb up at 24-11-4,
and 411 lb down and 242 lb up at 26-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility
of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�g'e
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
pn AA T
IYIi lt�n•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPIf quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T19781786
M11324
GRC
HIP
�Qty
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8,130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:30 2020 Page 2
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-17XeenZBSVGFnvBaxlVjW9jxmzm3tvGamxFvoHzXjGd
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-8=-54, 8-10=-54, 17-20=-20
Concentrated Loads (lb)
Vert: 3=-126(B)6=-107(B)8=-126(B)15=-50(B)16=-411(B)11=-411(B)12=-50(B)23=-107(B)25=-107(B)26=-107(B)27=-107(B)28=-107(B)29=-107(B)
30=-107(B) 32=-107(B) 33=-50(B) 34=-50(B) 35=-50(B) 36=-50(B) 37=-50(B)38=-50(B) 39=-50(B)
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781787
M11324
J1
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:31 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-AK5Os7apDoO5P3mmVT0y3NFEuMGVcYtj_a?SK4zXjGc
-1-0-0 1-0-0
1-0-0 1-M
3x4 =
Scale = 1:6.1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/de8 Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00
5 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.02
Vert(CT) -0.00
5 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2017rTP12014
Matrix -MP
Weight: 5 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (Ib/size) 3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical
Max Horz 2=48(LC 10)
Max Uplift 3=-4(LC 7), 2=-140(LC 10)
Max Grav 3=11(LC 15), 2=118(LC 1), 4=17(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 13=45ft; L=50ft; eave=6ft; Cat.
11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cart 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall �e
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information avallabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
�Qty
T19781768
M11324
J2
MONO TRUSS
4
1
Job Reference (optional)
Chambers Truss, Inc.,
Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:31 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-AK5Os7apDoO5P3mmVTOy3NFEuMFhcYtj_a?SKjzXjGc
-1-0-0 2-M i
1-0-0 2-M
3x4 =
Scale = 1:7.8
2-0-0
2-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00
7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.07
Vert(CT) -0.00
7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 Na n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MP
Weight: 8 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 2-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=37/Mechanical, 2=141/0-8-0, 4=23/Mechanical
Max Horz 2=67(LC 10)
Max Uplift 3=-28(LC 10), 2=-136(LC 10), 4=-3(LC 7)
Max Grav 3=42(LC 15), 2=141(LC 1), 4=31(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint
2 and 3 Ito uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781789
M11324
J3
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc.,
Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:32 2020 Page 1
ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-fWf03TbR_6Wy1DLy2AXBbaoPemaML77sDEkOsAzXjGb
1-0-0 3-0-0
1-0.0 3-0-0
3x4 =
3-0-0
LOADING (psf)
SPACING-
2-0-0
CSL
DEFL.
in
(loc)
I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
0.01
4-7
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.17
Vert(CT)
-0.01
4-7
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=64/Mechanical, 2=173/0-8-0, 4=37/Mechanical
Max Horz 2=85(LC 10)
Max Uplift 3=-54(LC 10), 2=-147(LC 10), 4=4(LC 10)
Max Grav 3=70(LC 15), 2=173(LC 1), 4=50(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:9.4
PLATES GRIP
MT20 244/190
Weight: 11 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purling.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 8=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint
2 and 4 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cen 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/l Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. .
Satefylnrormation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE ROYALE
T19781790
M11324
J4
MONO TRUSS
4
1
Job Reference o tional
Chambers Truss; Inc., Fort Pierce, FL
1-0-0
3x4 =
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:33 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-7iDnHoc3lQepfMv9cu2Q8oLW4AtR4SNOSuUZOczXjGa
4-0-0
4-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL) 0.02
4-7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.37
Vert(CT) -0.02
4-7 >999 240
BCLL 0.0 '
Rep Stress [nor YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 14 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=89/Mechanical, 2=206/0-8-0, 4=50/Mechanical
Max Horz 2=104(LC 10)
Max Uplift 3=-79(LC 10), 2=-161(LC 10), 4=-8(LC 10)
Max Grav 3=97(LC 15), 2=206(LC 1), 4=67(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 3, 161 lb uplift at joint
2 and 8 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. Ullegan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall q�
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additlonal temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781791
M11324
J5
MONO TRUSS
11
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
1-0-0
3x4 =
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:33 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-7iDnHoc3lQepfMv9cu2Q8oLSAApH4SNOSuUZOczXjGa
5-0-0 1
Scale = 1:12.7
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.70
Vert(LL) 0.06
4-7 >939 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.64
Vert(CT) -0.06
4-7 >964 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 17 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=115/Mechanical, 2=243/0-8-0, 4=63/Mechanical
Max Horz 2=123(LC 10)
Max Uplift 3=-104(LC 10), 2=-177(LC 10), 4=-9(LC 10)
Max Grav 3=125(LC 15), 2=243(LC 1), 4=87(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; 13=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at
joint 2 and 9 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd, Tampa FL 33610
Data:
March 24,2020
WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Not
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781792
M11324
J6
MONO TRUSS
4
1
Job Reference (optional)
Chambers Truss, Inc.,
Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:34 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-bvn9U8dhWjmgGWULAbZfg?BWa6ypvd9hYD6x2zXjGZ
-1-0-0 6-0-0
1-0-0 6-0-0
3x4 =
Scale=1:14.3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.34
Vert(LL) 0.11
4-7 >664 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.80
Vert(CT) -0.11
4-7 >652 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MP
Weight: 20 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=142/Mechanical, 2=275/0-8-0, 4=70/Mechanical
Max Horz 2=140(LC 10)
Max Uplift 3=-129(LC 10), 2=-192(LC 10), 4=8(LC 10)
Max Grav 3=155(LC 15), 2=276(LC 15), 4=100(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 ((b) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf, h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3, 192 lb uplift at
joint 2 and 8 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 41,111-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE ROYALE
T79781793
M11324
J8
MONO TRUSS
11
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:35 2020 Page 1
ID:kFvnsnOwY419Zh0 nM3lc6ylJ9g-35LXiUdJHlvXug3XkJ4uDDOp7_XMYMtJvCzgTVzXjGY
1-0-0 B-0-0
1-0-0 8-0-0
3x4
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deb
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.61
Vert(LL)
-0.14
4-7
>676
360
TCDL 7.0
Lumber DOL
1.25
BC 0.47
Vert(CT)
-0.30
4-7
>310
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Wind(LL)
0.26
4-7
>368
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
REACTIONS. (lb/size) 3=188/Mechanical, 2=348/0-8-0, 4=99/Mechanical
Max Horz 2=178(LC 12)
Max Uplift 3=-174(LC 12), 2=-226(LC 12), 4=13(LC 12)
Max Grav 3=195(LC 17), 2=348(LC 1). 4=141(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:17.5
PLATES GRIP
MT20 244/190
Weight: 26 lb Fr = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(1) 2-7-3 to 7-104 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3, 226 lb uplift at
joint 2 and 13 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
tdiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING . Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall�-
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP/i Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
T1978179M11324
=tional)
JA
MONO TRUSS
2
1
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:36 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-XHuvvgex2L1 OWgekHOc7mCiz5eNyVHp7S8siD?xzXjGX
-1-M 2-4-3
1-0.0 2-4-3
3x4 =
2-4-3
Scale = 1:8.3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00
7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.09
Vert(CT) -0.00
7 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 9 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 2-4-3 cc purlins.
BOT CHORD 2x4 SO No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 cc bracing.
REACTIONS. (lb/size) 3=45/Mechanical, 2=150/0-8-0, 4=28/Mechanical
Max Horz 2=73(LC 10)
Max Uplift 3=-37(LC 10), 2=139(LC 10), 4=-4(LC 7)
Max Grav 3=50(LC 15), 2=150(LC 1), 4=37(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 37 lb uplift at joint 3, 139 lb uplift at joint
2 and 4 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parametersand READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIl•7473 rev. 1e10312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall pp /��
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing IYIiTek*
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE ROYALE
T19781795
M11324
JB
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
3x4 =
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:36 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-XHuvvgex2L1 OWgekHOc7mOzl ONm1Hp7S8siD7xzXjGX
Scale = 1:12.5
5-5-11
S5-11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL, in
(loc) I/deb L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.38
Vert(LL) 0.10
4-7 >645 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.89
Vert(CT) -0.07
4-7 >898 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 19 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-5-11 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-0-0 oc bracing.
REACTIONS. (Ib/size) 3=127/Mechanical, 2=269/0-8-0, 4=63/Mechanical
Max Horz 2=114(LC 10)
Max Uplift 3=-109(LC 10), 2=-206(LC 10), 4=-6(LC 10)
Max Grav 3=127(LC 15), 2=269(LC 1), 4=90(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone;C-C for members and farces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 109 lb uplift at joint 3, 206 lb uplift at
joint 2 and 6 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not �®
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE ROYALE
T19781796
M11324
JC
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:37 2020 Page 1
I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-1USH6Afape9F7_Dwrk7MIeVGNnJvOGNbN WSmXNzXIGW
1-0-0 1-1-4
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.18
TCDL
7.0
Lumber DOL
1.25
BC 0.02
BCLL
0.0
Rep Stress Incr
YES
WB 0.00
BCDL
10:0
Code FBC2017rrP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=1 1 /Mechanical, 2=119/0-8-0, 4=4/Mechanical
Max Horz 2=50(LC 10)
Max Uplift 3=-6(LC 7), 2=-138(LC 10)
Max Grav 3=14(LC 15), 2=119(LC 1), 4=14(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:6.2
3x4 =
1-1-4
1-1-4
DEFL. in (too) I/deft Ud PLATES GRIP
Vert(LL) -0.00 5 >999 360 MT20 244/190
Vert(CT) -0.00 5 >999 240
Horz(CT) 0.00 4 n/a n/a
Weight: 5 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 1-1-4 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 6 lb uplift at joint 3 and 138 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not �®
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall�e
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781797
M11324
KJ5
MONO TRUSS
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:38 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-TgOgKWgCayH6I8c6PRebrr2OYBbJljcfbABK4pzXjGV
-1-5.0 3-11-0 7-0-2
' 1-5-0 3-11-0 3-1-2
2.83 12
3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.34
TCDL
7.0
Lumber DOL
1.25
BC 0.26
BCLL
0.0
Rep Stress Incr
NO
WB 0.00
BCDL
10.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
REACTIONS. (lb/size) 3=194/Mechanical, 2=233/0-11-5, 4=94/Mechanical
Max Horz 2=109(LC 8)
Max Uplift 3=-174(LC 8), 2=-191(LC 8)
Max Grav 3=198(LC 13), 2=233(LC 1), 4=133(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:16.7
DEFL. in (loc) I/deft Ud PLATES GRIP
Vert(LL) 0.09 4-7 >923 360 MT20 244/190
Vert(CT) -0.15 4-7 >563 240
Horz(CT) 0.00 2 n/a n/a
Weight: 23 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; 9=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3 and 191 lb uplift at
joint 2.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase--1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plf)
Vert: 2=0(F=27, B=27)-to-3=-95(F=-20, B=-20), 5=0(F=10, B=10)-to-4=-35(F=-8, B=8)
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. URegan PE No.58126
MiTek USA, Inc. FL Cert 6634
69D4 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall my
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE ROYALE
T19781798
M11324
KJ8
MONO TRUSS
2
1
Job Reference a tional
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:39 2020 Page 1
ID:_knGCA6bx7j2Sy1 HDXFw7ye3KX-xsa2XsggKGPzNHNlz89gN3bblbyjU50uqqxtcGzXjGU
1-5 0 7-2-7 11-3-0
1 5 0 7-2-7 4-0-9
3x4 = 3x4 =
5
7-2-7 11-0-12 11-3-D
7-2-7 3-10-5 012
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.21
TCDL
7.0
Lumber DOL
1.25
BC 0.25
BCLL
0.0
Rep Stress Incr
NO
WB 0.35
BCDL
10.0
Code FBC2017/TPI2014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=90/Mechanical, 2=46510-11-5, 5=409/Mechanical
Max Horz 2=178(LC 8)
Max Uplift 4=-91(LC 8), 2=-332(LC 8), 5=-223(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-875/541
BOT CHORD 2-6=535/842, 5-6=-535/842
WEBS 3-6=1/287, 3-5=-923/587
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
Vert(LL)
0.08
6-9
>999
360
MT20 244/190
Vert(CT)
-0.10
6-9,
>999
240
Horz(CT)
0.01
5
n/a
n/a
Weight: 44 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins.
BOT CHORD Rigid ceiling directly applied or 9-10-15 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 91 lb uplift at joint 4, 332 Ill uplift at joint
2 and 223 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 61 lb up at
2-11-0, 38 lb down and 61 lb up at 2-11-0, 8 lb down and 106 lb up at 5-8-15, 8 lb down and 106 lb up at 5-8-15, and 42 lb down
and 145lb up at 8-6-14, and 42 lb down and 145 lb up at 8-6-14 on top chord, and 31 lb up at 2-11-0, 31 lb up at 2-11-0. 11 lb
down and 31 lb up at 5-8-15, 11 lb down and 31 lb up at 5-8-15, and 31 lb down and 14 lb up at 8-6-14, and 31 lb down and 14 lb
up at 8-6-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pig
Vert: 1-4=-54, 5-7=-20
Concentrated Loads (lb)
Vert: 10=80(F=40, B=40)11=-5(F=-3, B=-3)12=-83(F=-42, B=-42)13=14(F=7, B=7)14=-21(F=11, B=-11)15=-50(F=-25,
B=-25)
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
,& WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall p p�
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VI iTe k•
Is always required for stability and to prevent collapse with possible personal Injury and property damage, For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, sea ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T19781799
M11324
KJA
MONO TRUSS
�Qby
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
-1-2-9
3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.21
TCDL
7.0
Lumber DOL
1.25
BC 0.17
BCLL
0.0
Rep Stress Incr
NO
WB 0.00
BCDL
10.0
Code FBC2017frPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
REACTIONS. (lb/size) 3=142/Mechanical, 2=181/0-9-11, 4=69/Mechanical
Max Horz 2=97(LC 8)
Max Uplift 3=-129(LC 8), 2=150(LC 8)
Max Grav 3=145(LC 13), 2=181(LC 1), 4=104(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:39 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-xsa2XsggKGPzNHN Iz89gN3bbNbzyUAsuggxtcGzXjGU
Scale = 1:13.6
DEFL. in (loc) I/defi Lid PLATES GRIP
Vert(LL) 0.04 4-7 >999 360 MT20 2441190
Vert(CT) -0.07 4-7 >974 240
Horz(CT) 0.00 2 n/a n/a
Weight: 20 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3 and 150 lb uplift at
joint 2.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pig
Vert: 1-2=-54
Trapezoidal Loads (plf)
Vert: 2=0(F=27, B=27)-to-3=-81(F=-14, B=-14), 5=0(F=10, B=10)-to-4=-30(F=-5, B=-5)
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
°
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
Nil
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE ROYALE
T19781800
M11324
KJB
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Tue Mar 24 12:54:40 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-Q28QIChS5ZXc_RyV Wsg3wG7oh7KKDd623UgR8izxjGT
-1-2-9 4-11-9
1-2-9 4-11-9
R,: IA = 1.11 7
3x4 =
4-11.9
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.11
Vert(LL) -0.02
4-7 >999 360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC - 0.10
Vert(CT) -0.03
4-7 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.00
Horz(CT) 0.00
2 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 17 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-11-9 oc pudins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=95/Mechanical, 2=148/0-9-11, 4=46/Mechanical
Max Horz 2=75(LC 8)
Max Uplift 3=-84(LC 8), 2=-136(LC 8)
Max Gram 3=95(LC 1), 2=148(LC 1), 4=77(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 84 lb uplift at joint 3 and 136 lb uplift at
joint 2.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plf)
This item has been
Vert: 2=0(F=27, l3=27)-to-3=-67(F=-7, B=-7), 5=0(F=10, B=10}1to4=25(F=-2, B=2)
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cart 6634
0904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7479 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
HV
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Duality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply=ptional)
T19
M11324
MV2
VALLEY
1
Chambers Truss, Inc., Fort Pierce, FL
2-0-0
3x4
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:41 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-uFioyXi4stfhcbXh4ZBITUg_ROhoy4MBl8Q_h8zXjGS
4.00 12
Scale = 1:6.1
LOADING (psf)
SPACING- 2-0-0
CS].
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.04
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.02
Vert(CT) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
2 n/a n/a
BCDL 10.0
Code FBC2017frP12014
Matrix-P
Weight: 5 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 2-0-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=41/2-0-0, 2=30/2-0-0, 3=11/2-0-0
Max Horz 1=21(LC 10)
Max Uplift 1=-20(LC 10), 2=-30(LC 10)
Max Grav 1=42(LC 15), 2=32(LC 15), 3=22(LC
3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint 1 and 30 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cart 8634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component. not ��AA
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall -•Y�•
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T19781802
M11324
MV4
VALLEY
�Qty
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
3x4
4-0-0
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:41 2020 Page 1
ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-uFioyXi4stfhcbXh4ZBITUgvHOfUy4MB18Q h8zXjGS
3x4 11
Scale = 1:9.4
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.37
Vert(LL)
n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.17
Vert(CT)
n/a n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.00 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Weight: 12 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc puriins,
BOT CHORD 2x4 SP No.3
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=109/4-0-0, 3=109/4-0-0
Max Horz 1=56(LC 10)
Max Uplift 1=-54(LC 10), 3=-72(LC 10)
Max Grav 1=112(LC 15). 3=117(LC 15)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
NOTES-
1•) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 1 and 72 lb uplift at
joint 3.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 8634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - v.1Ity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall p qr
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Addiflonal temporary and permanent bracing 1 VI iTe k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Symbols Numbering System ® General Safety Notes
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
Ole
For 4 x 2 orientation, locate
plates 0- 'lid' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
`Plate location details available in MiTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSIITP11: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
1 2 3
TOP CHORDS
Ct-2 C2-3
WEBS q,Q 4
0 of
d
a
E— C7-e c6-7 C5-6 00
BOTTOM CHORDS
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek® All Rights Reserved
MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear lightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSIIrPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.