Loading...
HomeMy WebLinkAboutEngineering, product approvals, metal FILE Cbloy'4--�aoos -010& y" Southeast Building Engineers, LLC ° 3578 Rolling Acres Road � � 7� SEBE:;.t� Pace,FL 32571 � 772-774-9086 REVIEWED FOR s.sanders sebeningeers.com � ® �,B JU , OUN'TY contractor: Arc Roofing and Remodeling Inc. `r-Dafe: F01 Owner: Kilavaney Property Co. General Notes �r Job Address: 8573 S. US Hwy#1 1. Entire roof deck to be renailed w/8d Metal Roofing "5V" Cimp Panel ringshank nails @ 6"o.c. through out New Roof_ Re-Roof X Recovering_ Repair Area_ METAL ROOF PLAN DRAWING IS SCHEMATIC IN NATURE NOT ACTUAL SHAPE OF BUILDING ---------------------------- W I I i 3 i 0 �------------- o � OI lO I 122) �Iaa �I IQ � ASCE7-10& FBC 2017 6 h Edition Enclosed Bldg. X Semi Enclosed Bldg Open Part2 Low Rise C&C Simplified Risk Cat 2N= 160 /Exposure B /A= - /Kzt= 1.0/h= <30' / 7:12 Min to 12:12 Max Pitch Roof System 26 GA "5V" Cimp Panel NOA FL-29444.4 Zone 1 (Table R301.2(2)) -27.8 X Coefficient(Table R301.2(3))_1.0_ = -27.8 Zone 2 (Table R301.2(2)) -32.4 X Coefficient(Table R301.2(3))_1.0_ = -32.4 a= 3'-6" Zone 3 (Table R301.2(2)) -32.4 X Coefficient(Table R301.2(3))_1.0_ = -32.4 a= 3'-6" X 3'-6" Max Design Pressure per NOA -116.0 Deck Type Plywood Thickness Min 15/32" Underlayment Tri-Built SA, HT, TU, No. of Plies 1 Fastener Type Self-Adheared Spacing Underlayment NOA 'FL-16048.1 Insulation Type Size Type of Fasteners: Spacing Field Perimeter Corner Drip Edge Size 2"x2" Drip Material 26 GA Flashing Material 26 GA Type of Fasteners for Metal Roof Panels: #10-15 Woodtite Spacing: Field 12" O.C. Perimeter 12" O.C. Corner 12" O.C. Page 1 1 • I I r' 3 flc BCIS Home l Log In User Registration j Hot Topics I Submit Surcharge I Stats&Facts i Publications j Contact Us ( BCIS Site Map ; Links Search j �londa ,)Product Approval USER:Public User PILE 2, _ y Product Approval Menu>Product or Agglication Search>Application List>Application Detail FL# FL29444-RU" Application Type New Code Version 2017 REVIEWED � Application Status Approved BODE COMPLIANCE Comments TO. LUCIE COUNTY Archived 0 C C Product Manufacturer Integrity Metals LLC Address/Phone/Emali 2604 B Piper Drive Vero Beach,FL 32960 (772)584-2654 Admin@integritymetalsfl.com Authorized Signature Joe Keene Admin inte ri metaisfl.com @ 9 tY Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer _+ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Locke Bowden Evaluation Report Florida License PE-49704 Quality Assurance Entity PRI Construction Materials Technologies,LLC Quality Assurance Contract Expiration Date 05/25/2023 Validated By Diane Marotta,P.E. L J Validation Checklist-Hardcopy Received Certificate of Independence FL29444 RO COI Integrjty Metals Integril-ok IM 100 Min .029 AL Nail Strip. CS5.izd� Referenced Standard and Year(of Standard) Standard Year UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D I i Date Submitted 04/17/2019 Date Validated 04/17/2019 Date Pending FBCApproval 04/26/2019 Date Approved 06/18/2019 Date Revised 07/29/2020 Summary of Products FL# Model,Number or Name Description 29444.1 IntegriLok IM100 Min. .029"AL Nail IntegriLok IM100 Min. .029"AL Nail Strip Strip Limits of Use Installation Instructions Approved for use in HVHZ: No FL29444 RO II Integrity Metals IntegriLok IM 100 Min .029 Approved for use outside HVHZ:Yes AL Nail Strip-CSS.pdf Impact Resistant: N/A Verified By: Locke Bowden,P.E.49704 Design Pressure:+N/A/-153.5 Created by Independent Third Party:Yes Other:-153.5 psf @ 5-1/4"O.C.WITH adhesive-57.62 psf @ Evaluation Reports 5-1/4"O.C.WITHOUT adhesive Install per manufacturer's FL29444 RO AE Integrity Metals IntegriLok IM 100 Min.029 install details and in accordance with FBC 2017. AL Nail Strip-CSS.Rdf Created by Independent Third Party:Yes 29444.2 Min.26GA Galvalume IM36 AG Panel Min.26GA Galvalume IM36 AG Panel over OSB&CDX Limits of Use Installation Instructions Approved for use in HVHZ: No FL29444 RO II Integrity Metals Min,26GA Galvalume IM36 Approved for use outside HVHZ:Yes AG'Panel--CSS.pdf Impact Resistant: N/A Verified By: Locke Bowden,P.E.49704 Design Pressure: +N/A/-93.5 Created by Independent Third Party:Yes Other:-93.5 psf @ 12"O.C. Fastening Pattern: Evaluation Reports 9"x9"x9"x6.5"x2.5'-78.5 psf @ 18"O.C.Fastening Pattern: FL29444 RO AE Integri Metals Min, 26GA Galvalume IM36 9"x9..x9"x9"Install per manufacturer's details and in AG Panel-CSS.pdf accordance with FBC 2017. Created by Independent Third Party:Yes 29444.3 Min.26GA Steel 1.5"Snap Lock Min.26GA Steel 1.5"Snap Lock over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL29444 RO II IntegLity Metals Min. 26GA Steel 1.5 Snap Approved for use outside HVHZ:Yes Lock-CSS.(df Impact Resistant: N/A Verified By: Locke Bowden, P.E.49704 Design Pressure: +N/A/-86 Created by Independent Third Party:Yes Other:-86 psf'@ 12"O.C.Install per manufactuer's install Evaluation Reports details and in accordance with FBC 2017. FL29444 RO AE IntegLty Metals Min.26GA Steel 1.5 Snap Lock-CSS.pdf' Created by Independent Third Party:Yes -� '29444 4 ;Mln 26GA Steel 5,V Crimp:Panel; Mm_26GA Steel 5 V Crimp Panel^over 15%32 Plywood Limits of Use a.ation'Tnstruc#ions I Approved for use in HVHZ: No FL2 44 R0 II.In `Irty Met V Crimp Panel' CSS pdf' Approved for use outside HVHZ:Yes a cke Bowden P E 49704 -� Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-116 Evaluation Reports Other:-116 psf @ 12"O.C.Install per manufacturer's details FL29444 RO AE Integrity Metals 5 V Crimp Panel-CSS.pdf and in accordance with FBC 2017. Created by Independent Third Party:Yes u39 YJCXt Contact Us::2601 Blair stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Cooght 2007-2013 State of Florida.::&jvact5jiiLement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: F.1i`ecY Credit Card Safe i I FY- �" � ...- e r�—_ r_,' '9 1 ,t ....t w..-• 3 r.3.,.^.{_4 T,+.°.h r +, 2604 B Piper Drive Vero Beach, Ft 32960 INTEGRITYMETALS 772-284-5613 hw.�. 'L4-e".„r' s'..j1�3=.» a ri �... "4,sC-• '-tf- - .k-E ._r �.r°.-"'. c-: S.-.-...6+_ss.:.. fit.. ua�.aq ',,+' `°t s5.:.:.R.[ cr _ s- .# ; S'tyT ,• Compliant with Florida Building Code 2017(61h ed.) Compliant with Florida Product Approval Rule#61G20-3 -Compliant Active Quality Assurance Program —� Product.�Jlh` 6GA°SV Crimptren ulesi 24 c:overage Max. Rib Height.3/g„ Minimum 15/32"plywood over supports at maximum 24"O.C. Design of plywood and`plywood supports are outside the scope of this evaluation. Must be designed in accordance*/Florida Building Code 2017. 34 penetration thru plywood supports 24"max. o.c. Corrosion Resistant Compliant: FBC Sec. iS07.4.3 —� Fasteneic0-15 Woodt�te fastener spaced Underlayment: To Sec. 1507, Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Method.l: Loads DESIGN PRESSURE* 116 PSF , SPACING Reference Data: Intertek Testing(TST 1527) REPORT#17226.03-450-44 RO UI.580-06 *Design Pressure safety margin of 2.1 *'This test is owned by Quality Metal fabricators, who has given permission to share testing. Certificate of independence: Locke Bowden,P.E.does not have,nor will acquire a financial Interest in any company manufacturing or distributing products under"this evaluation. Locke Bowden,P.E.is not owned,operated,or controlled by an company,manufacturer,or distributin Mnd under t� report. y ,p� i�Yii,,r► _( B AP 49304. ;ea I • TE 4,r r,�'o •. PL0P. 'O�,Z Integrity Metals Min. 26GA 5V Crimp Roof Panel Installation Details Limitations: 1.Underlayment to be compliance with current Florida Building Code(FBC)2017 6T"ed..see Chart 1507.1.1 2.Minimum slope to be compliant with Florida Building Code 2017 6th ed.,and per with Manufacturer's installation reference. 3.Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-1) 4.Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. S. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6th ed.,Chapter 22 Steel,Chapter 23 Wood and Chapter 16 Structural Loading. 7.This report does not imply warranty,installation,recommended product use outside of this report. 24" 3/811 PROFILE FASTENER PATTERN @ 12" O.C. ZONE 2 GAHLE.ROOF a., NIP RODF -a. a ;ZOtdE 2 a ZONE 3 ._ . RIDGE •' --RIDGE . ,i ZONE t ZONE 1 EAVE -ZONE 3 fJiVE.