Loading...
HomeMy WebLinkAboutAPPROVED SH7600NOA MIAMI•DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy PGT Industries,Inc. 1070 Technology Drive North Venice,FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami—Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone.- DESCRIPTION: Series "SH7600A"Aluminum Single Hung Window—N.I. APPROVAL DOCUMENT: Drawing No. 7600NOA-1, titled "Aluminum Single Hung Install (NI)", sheets 1 through 12 of 12, dated 04/01/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami-Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No. 18-0430.07 MIAMI•DADE COUNTY Expiration Date: August 23,2023 (0116 Approval Date: August 23,2018 YeP Page 1 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. 7600NOA-1, titled "Aluminum Single Hung Install (NI), sheets 1 through 12 of 12, dated 04/01/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94 along with marked-up drawings and installation diagram of an aluminum single hung window,prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-18-7835.1, dated 04/03/18, signed and sealed by Idalmis Ortega, P.E. 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2)Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94 along with marked-up drawings and installation diagram of an aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-18-7835.2, dated 05/04/18, signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6` Edition (2017), dated 04/23/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). ManuZi Vez z,P.E. Product Contminer NOA No. 18-0430.07 Expiration Date: August 23,2023 Approval Date: August 23,2018 E- 1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of conformance to FBC 6tn Edition (2017), dated April 24, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated April 24, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 18-0005R issued by the Product Control Section, dated 01/16/18, signed by Manuel Perez, RE G. OTHERS 1. None. Manuel Pe a P.E. Product Control x iner NOA No. 18-0430.07 Expiration Date: August 23,2023 Approval Date: August 23,2018 E-2 SERIES SH7600A NON-IMPACT RESISTANT SINGLE HUNG WINDOW "I-1\17-13/16"MAX.O.0 DESIGN PRESSURE RATING IMPACT RATING 1)THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE REQUIREMENTS OF S18-3/8"MAX. VARIES PER GLASS TYPE, NOT RATED FOR THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ). // SEE SHEETS 2-5 IMPACT RESISTANCE 2)SHUTTERS ARE REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. !! / 3)FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY 17-3/4"MAX. 17-3/4" 52-1/8"MAX. BUCK WIDTH APPROVED MASONRY ANCHORS. MATERIALS USED FOR ANCHOR EVALUATIONS WERE (17-1/4"BUCK) 9-1/2"MAX. X.MAX. 4-11/16"MA SOUTHERN PINE,ASTM C90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN.KSI PER � (9"MAX.BUCK) �I I-t-- 5"MAX.O.C. ANCHOR TYPE. B,SEE O.C. D,SEE wa a SHEETS 8&9 SHEET 10 € $ ��$ ¢ 4)ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X A,SEE C,SEE WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD BUCKS SHEETS 8&9 SHEET 10 DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER. 1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND SECURED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE.WOOD EQUALLY BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER,(EOR)OR SPACED ARCHITECT OF RECORD, (AOR). ANCHORS PER TABLES 6&7 1 17-3/16"MAX.O.C. 5)ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR O ( I / i 84" o O STUCCO. USE ANCHORS OF SUFFICIENT LENGTH TO ACHIEVE REQUIRED MIN.EMBEDMENT. MAX. - 83" INSTALLATION ANCHORS SHOULD BE SEALED.OVERALL SEALING/FLASHING STRATEGY FOR TIP MAX. WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE 12-1/16"MAX.O.C. TO BUCK X SCOPE OF THESE INSTRUCTIONS. ' I HEITIP GHT + ° X I HEIGHT EQUALLY SPACED / 6) 1/4"MAX.SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS ANCHORS PER 13-5/16"MAX.O.C. NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. TABLES 6&7 l 00 1 b Y _ 5"MAX. ° W ? (n 7)DESIGN PRESSURES: 9-1/2"MAX. / O.C. ( / C > w p ?j nab A. NEGATIVE DESIGN LOADS BASED ON STRUCTURAL TESTING AND GLASS PER ASTM (9"MAX.BUCK) O 0 co E1300. B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE,STRUCTURAL TESTING A °� o� TOT O Q AND GLASS PER ASTM E1300. NO ANCHORS AT SILL Z O w (n O C. DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN,ASD. B D - 4-11/16"MAX. _j c� - 53-1/8"MAX.TIP TO TIP WIDTH ��V WEEP NOTCH l 1"WEEP NOTCH Q U- o ° F W O 8)THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS AT EACH END AT EACH END Z (p 0D x _-) (p CORRESPONDING TO THE REQUIRED DESIGN PRESSURE.THE 33-1/3%STRESS INCREASE = W - E Z g ELEVATION FOR TYP. FLANGE FRAME ELEVATION FOR TYP. FIN FRAME SHOWN WITH U C) o o o uMoa HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.THE 1.6 LOAD DURATION FACTOR W - 00 J 'ON WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD.ANCHORS THAT COME INTO SHOWN WITH EQUAL-LITE CONFIGURATION EQUAL-LITE CONFIGURATION F- w ¢ Q JMo CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE r, > a O FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. C:) Z 00 Z v - Q N 9)METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER U' > CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING GENERAL NOTES................................................. 1 Z W LL TABLE 1:ALLOWABLE GLASS TYPES ELEVATIONS................. . . . .. . . . .. . . ....... 1 JURISDICTION. �� � � � � �� = W Glass DP DESIGN PRESSURES/GLAZING DETAILS........ 2-5 10)REFERENCES:TEST REPORTS FTL 18-7835.1 &18-7835.2; ELCO ULTRACON NOA; ELCO Description (Listed from Exterior to Interior) ANCHOR QUANTITIES..........................................6-7 O N -1CRETEFLEX NOA; NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, Type Table # INSTALLATION, FLANGE......................................8 Z H ANSI/AF&PA NDS&ALUMINUM DESIGN MANUAL INSTALLATION, EQUAL LEG.................................9 = _ aa4S 1 1/8" Annealed 2 INSTALLATION, INTEGRAL FIN............................ 10 D z 11)APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. 2 13/16" IG: 1/8" Annealed Cap, Airspace, 1/8" Annealed 3 EXTRUSION PROFILES..... Z 11 U J Q ASSEMBLY&PARTS LIST....................................12 O Q 3 3/16" Annealed 3 z o 4 13/16" IG: 3/16" Annealed Cap, Airspace, 3/16" Annealed 4 w w FIGURE A:ALLOWABLE SASH CONFIGURATIONS AND SHAPES 5 1/8" Tempered 5 CODES/STANDARDS USED: 0 J W � -� WIDTH 6 13/16" IG: 1/8" Tempered Ca Airspace, 1/8" Tempered 5 •2017 FLORIDA BUILDING CODE(FBC),6TH EDITION Q (D -�� WIDTH �� WIDTH E►- ��- p P p p •ASTM E1300-09 a�}il 'asaQ sauas 3/16" Tempered 5 •ANSI/AF&PA NDS-2015 FOR WOOD CONSTRUCTION ( I I T *ALUMINUM DESIGN MANUAL,ADM-2015 I I I 8 13/16 IG: 3/16" Tempered Cap, Airspace, 3/16' Tempered 5 •AISI S100-12 •�` NY LYNN '�, •AISC 360-10 0 w w w w Q�,• �� x x x x J USER INSTRUCTIONS: No. 58705 i + 1) DETERMINE THE SITE SPECIFIC,WINDOW OPENING'S DESIGN PRESSURE REQUIREMENT FROM ASCE 7. -10 RECTANGULAR RADIUS-TOP RECTANGULAR 2)KNOWING YOUR GLAZING OPTION (TABLE 1),WINDOW CONFIGURATION AND SIZE, DETERMINE YOUR WINDOWS C(/ DESIGN PRESSURE FROM TABLES �` 2-5. IT MUST EQUAL OR EXCEED THE DESIGN PRESSURE REQUIREMENT FOR THE WINDOW OPENING OBTAINED IN STEP 1. O STATE OF WITH EQUAL WITH PROVIEW WITH CUSTOM 4)DETERMINE THE ANCHOR QUANTITY FROM TABLES 6&7. '� p F LITE SASH SASH SASH CORID .•' G� 5) INSTALL AS PER SHEET 8 FOR FLANGE INSTALLATION,SHEET 9 FOR EQUAL LEG INSTALLATION OR SHEET 10 FOR INTEGRAL FIN INSTALLATION. ALL SHAPES WITH ALL SASH CONFIGURATIONS ARE APPROVED.SHAPES /'ONAL, MAY BE USED BY INSCRIBING THE SHAPE IN A BLOCK AND OBTAINING NOTE:DESIGN PRESSURE RATING DETERMINATION IS THE SAME PROCESS FOR ALL FRAME TYPES(FLANGE, INTEGRAL FIN OR EQUAL LEG/BOX). � / r r 1 1 1 1 r 0 N� DESIGN PRESSURES AND ANCHORAGE FOR THAT BLOCK SIZE FROM THE A.LYNN MILLER,P.E. TABLES ON THE FOLLOWING SHEETS. P.E.#58705 TABLE 2: Bottom Sash Sash Height Design Pressure(Ibslft)for Glass Type 1 Description Range(in) Tip to Tip Width for Gieen Range 18" 25" 33" 37" 41" 45" 49" 53-1/8" 24" Equal-lite 12.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -127.1 +80.0 -113.8 +80.0 -103.1 +80.0 -93.9 Equal-lite 15.964 +80.0 -130.0 +80.0 -130.0 +80.0 -104.0 +80.0 -95.5 +80.0 -89.1 +80.0 -84.2 +80.0 -81.4 +74.8 -74.8 1/8"ANNEALED 31" Standard Pro\Aew 12.994-15.963 +80.0 -130.0 +80.0 -127.0 +80.0 -86.9 +76.0 -76.0 +66.7 -66.7 +60.7 -60.7 +57.2 -57.2 +53.5 -53.5 GLASS Shortest 12.464-12.993 +80.0 -130.0 +80.0 -124.0 +80.0 -84.0 +73.8 -73.8 +63.2 -63.2 +57.2 -57.2 +52.4 -52.4 +49.1 -49.1 Equal-lite 19.652 +80.0 -130.0 +80.0 -124.0 +80.0 -84.0 +73.8 -73.8 +63.2 -63.2 +57.2 -57.2 +52.4 -52.4 +49.1 -49.1 30 � k xv Pk Hag'Standard Pro�iew 15.944-19.651 +80.0 -130.0 +80.0 -110.0 +80.0 -80.6 +70.3 -70.3 +60.2 -60.2 +52.2 -52.2 +46.8 -16.8 +41.0 -41.0 � J �1. 38-3/8" Custom Size 15.131 -15.943 +80.0 -130.0 +80.0 -102.0 +78.2 -78.2 +68.7 -68.7 +59.3 -59.3 +51.7 -51.7 +46.2 -46.2 +40.0 -40.0 26 ai- Custom Size 14.131 -15.130 +80.0 -124.0 +80.0 -98.5 +77.1 -77.1 +67.4 -67.4 +58.9 -58.9 +51.5 -51.5 +46.1 -46.1 +39.9 -39.9 1/2"NOM. } ,^ Shortest 12.464-14.130 +80.0 -118.0 +80.0 -95.2 +75.4 -75.4 +66.1 -66.1 +58.5 -58.5 +51.3 -51.3 +46.1 -46.1 +40.0 -40.0 GLASS BITE EXTERIOR Equal-lite 22.964 +80.0 -130.0 +80.0 -110.0 +80.0 -80.6 +70.3 -70.3 +60.2 -60.2 +52.2 -52.2 +46.8 -46.8 +41.0 -41.0 Custom Size 20.131-22.963 +80.0 -124.0 +80.0 -98.5 +77.1 -77.1 +67.4 -67.4 +58.9 -58.9 +51.5 -51.5 +46.1 46.1 +39.9 -39.9 Standard Promew 18.594-20.130 +80.0 -118.0 +80.0 -95.2 +75.4 -75.4 +66.1 -66.1 +58.5 -58.5 +51.3 -51.3 +46.1 -46.1 +40.0 -40.0 74 45" Custom Size 16.131-18.593 +80.0 -102.0 +80.0 -85.0 +69.9 -69.9 +62.1 -62.1 +55.7 -55.7 +50.4 -50.4 +45.3 -45.3 +40.0 -40.0 34 Custom Size 15.131-16.130 +80.0 -98.0 +80.0 -81.9 +68.1 -68.1 +60.6 -60.6 +54.6 -54.6 +49.7 -4g.7 +44.8 �34.8 +39.9 -39.9 'o Custom Size 14.131-15.130 +80.0 -95.5 +79.4 -79.4 +66.4 -66.4 +59.2 -59.2 +53.6 -53.6 +48.7 -48.7 +44.3 -44.3 +39.7 -39.7 GLASS TYPE 1 Shortest 12.464-14.130 +80.0 -89.4 +74.6 -74.6 +62.1 -62.1 +56.3 -56.3 +51.1 -51.1 +46.7 46.7 +42.7 -42.7 +38.6 -38.6 Equal-lite 24.964 +80.0 -130.0 +80.0 -102.0 +78.2 -78.2 +68.7 -68.7 +59.3 -59.3 +51.7 -51.7 +46.2 -46.2 +40.0 -40.0 Custom Size 22.131 -24.963 +80.0 -112.0 +80.0 -92.0 +73.5 -73.5 +64.8 -64.8 +57.9 1 -57.9 +51.0 -51.0 +46.0 -46.0 +40.0 -40.0 L 6) Standard ProNAew 20.194-22.130 +80.0 -102.0 +80.0 -85.0 +69.9 -69.9 +62.1 -62.1 +55.7 -55.7 +50.4 -50.4 +45.3 45.3 +40.0 40.0 _ a) = 49" Custom Size 18.131 -20.193 +80.0 -95.5 +79.4 -79.4 +66.4 -66A +59.2 -59.2 +53.6 -53.6 +48.7 -48.7 +44.3 -44.3 +39.7 -39.7 b Y _L ? U) F Custom Size 16.131-18.130 +80.0 -89.4 +74.6 -74.6 +62.1 -62.1 +56.3 -56.3 +51.1 -51.1 +46.7 -46.7 +42.7 -42.7 +38.6 -38.6 � Custom Size 14.131 -16.130 +80.0 -84.6 +69.5 -69.5 +59.2 -59.2 +53.7 -53.7 +48.8 -48.8 +44.8 -44.8 +40.9 -40.9 +37.6 -37.6 W w O > nay 'IT O Shortest 12.464-14.130 +80.0 -81.9 +64.0 -64.0 +56.4 1 -56.4 +51.0 1 -51.0 +46.6 -46.6 +42.3 -42.3 +39.4 -39.4 +36.0 -36.0 0 w O i Equal-lite 25.777 +80.0 -124.0 +80.0 -98.5 +77.1 -77.1 +67.4 -67.4 +58.9 -58.9 +51.5 -51.5 +46.1 -46.1 +39.9 -39.9 N z w a}°a Q Custom Size 24.131-25.776 +80.0 1 -112.0 +80.0 -92.0 +73.5 -73.5 +64.8 -64.8 +57.9 -57.9 +51.0 -51.0 +46.0 -46.0 +39.9 -39.9 O "4- F w O Standard Pro�iew 20.844-24.130 +80.0 -98.0 +80.0 -81.9 +68.1 -68.1 +60.6 -60.6 +54.6 -54.6 +49.7 -49.7 +44.8 -44.8 +39.9 -39.9 J J O a- Z O 50-5/8" Custom Size 19.131 -20.843 +80.0 -92.6 +77.0 -77.0 +64.1 -64.1 +57.7 -57.7 +52.3 52.3 +47.7 -47.7 +43.8 -43.8 +39.2 -39.2 Z (D o2= � Custom Size 16.131-19.130 +80.0 -84.6 +69.5 1 -69.5 +59.2 -59.2 1 +53.7 -53.7 +48.8 -48.8 +44.8 -44.8 +40.9 -40.9 +37.6 -37.6 1 = U j N Z 40 Shortest 13.089*-16.130 +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 +49.8 -49.8 +45.5 -45.5 +41.3 -41.3 +38.6 -38.6 +35.1 -35.1 W U 00 J J uM°aQ ° _¢ N Equal-lite 31.964 +80.0 95.5 +79.4 79.4 +66.4 66.4 +59.2 59.2 +53.6 53.6 +48.7 48.7 +44.3 44.3 +39.7 39.7 W c7 Q sM0 Custom Size 28.131 -31.963 +80.0 1 -84.6 +69.5 -69.5 +59.2 -59.2 +53.7 -53.7 +48.8 -48.8 1 +44.8 -44.8 +40.9 -40.9 +37.6 -37.6 > of F- 63" Standard Promew 25.794-28.130 +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 +49.8 -49.8 +45.5 -45.5 +41.3 -41.3 +38.6 -38.6 +35.1 -35.1 Z 0') ILZ O Shortest 25.049*-25.793 +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 +49.8 -49.8 +45.5 -45.5 +41.3 -41.3 +38.6 -38.6 +35.1 -35.1 U N_ Equal-lite 34.964 +80.0 -86.5 +72.2 1 -72.2 +60.6 1 -60.6 +55.0 -55.0 +49.9 -49.9 +45.8 45.8 +41.7 -41.7 +38.1 -38.1 Z ILL 69" Custom Size 33.131-34.963 +80.0 -83.1 +66.7 -66.7 +57.8 -57.8 1 +52.1 -52.1 +47.6 -47.6 +43.5 -43.5 +40.1 -40.1 +36.8 -36.8 0 Shortest 31.049*-33.130 +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 +49.8 -49.8 +45.5 1 -45.5 +41.3 41.3 +38.6 -38.6 +35.1 -35.1 = CV Equal-lite 36.964 +80.0 -83.1 +66.7 -66.7 +57.8 -57.8 +52.1 -52.1 +47.6 -47.6 +43.5 -43.5 +40.1 -40.1 +36.8 -36.8 ® N J rn N 73" Custom Size 36.131 -36.963 +80.0 -81.9 +64.0 -64.0 +56.4 -56A +51.0 -51.0 +46.6 -46.6 +42.3 -42.3 +39.4 -39.4 +36.0 -36.0 k (` Shortest 35.049*-36.130 +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 +49.8 -49.8 +45.5 -45.5 +41.3 -41.3 +38.6 -38.6 +35.1 -35.1 = Z ways 76" Tallest 38.464* +80.0 1 -80.6 1 +61.7 1 -61.7 +55.1 -55.1 +49.8 -49.8 +45.5 -45.5 +41.3 -41.3 1 +38.6 -38.6 +35.1 -35.1 *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-37.536 O J 00 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS: BUCK HEIGHT-36.536 Z CO (0 MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-37.951 w < F_ MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-36.951 U J d Q � al��l asaN sauas LYN/V4. �'�•, \,\GENSF No. 58705 0 ". STA F �GORIOP •' \�� 1)TIP 2)FOR SO P DIMENSIONS OT SHOWN, ROUND FOR INTEGRAL THE FIN AND EQUAL-LEG WINDOWS, SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. //'/ ®0NA6 SIZES 0 3)FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. A.LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 TABLE 3: Bottom Sash Sash Height Design Pressure(lbs/ft2)for Glass Types 2&3 Description Range(in) Tip to Tip Width 13/16"NOM. GLASS STACK for Given Range � 18" 25" 33" 37" 41" 45" 49" 53-1/8" 24" Equal-lite 12.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -124.8 AIRSPACE ANNEALED GLASS Equal-lite 15.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.6 +80.0 -109.6 +80.0 -99.5 1/8" 31" Standard Pro�iew 12.994-15.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.1 +80.0 -109.3 +80.0 -102.6 +80.0 -93.0 31 f Shortest 12.464-12.993 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -113.8 +80.0 -103.0 +8&0 -94.3 +80.0 -88.4 Equal-lite 19.652 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 113.8 +80.0 102.8 +80.0 92.2 +80.0 83.3 5�OR 5B '£ 1 t Blaid n8 Standard Promew 15.944-19.651 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.0 +80.0 -108.4 +80.0 -94.0 +80.0 -84.2 +73.8 -73.8 EXTERIOR G 38-3/8" Custom Size 15.131 -15.943 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -114.0 +80.0 -101.0 +80.0 -90.6 +80.0 -81.6 +72.0 -72.0 Custom Size 14.131 -15.130 +80.0 -130.0 +80.0 -130.0 +80.0 -129.0 +80.0 -110.0 +80.0 -97.7 +80.0 -87.1 +78.8 -78.8 +71.8 -71.8Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -124.0 +80.0 -107.0 +80.0 -94.8 +80.0 -84.0 +76.8 -76.8 +68.9 -68.9 Equal-lite 22.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.1 +80.0 -104.4 +80.0 -91.7 +80.0 -81.8 +73.6 -73.6 Custom Size 20.131 -22.963 +80.0 -130.0 +80.0 -130.0 +80.0 -129.0 +80.0 -110.0 +80.0 -97.7 +80.0 -87.1 +78.3 -78.3 +70.3 -70.3 35 OR 35B Standard Promew 18.594-20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -124.0 +80.0 -107.0 +80.0 -94.8 +80.0 -84.0 +76.8 -76.8 +68.9 -68.9 GLASS TYPE 2 45" Custom Size 16.131 -18.593 +80.0 -130.0 +80.0 -130.0 +80.0 -112.0 +80.0 -99.1 +80.0 -87.5 +79.2 -79.2 +72.0 -72.0 +62.5 -62.5 Custom Size 15.131 -16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -109.0 +80.0 -96.7 +80.0 -85.4 +78.0 -78.0 +70.8 -70.8 +61.5 -61.5 Custom Size 14.131 -15.130 +80.0 -130.0 +80.0 -130.0 +80.0 -105.0 +80.0 -94.5 +80.0 -83.5 +76.8 -76.8 +69.7 -69.7 +60.6 -60.6 a Shortest 12.464-14.130 +80.0 -130.0 +80.0 -127.0 +80.0 -99.8 +80.0 -90.7 +80.0 -81.2 +74.8 -74.8 +67.7 -67.7 +59.6 -59.6 Equal-lite 24.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -114.0 +80.0 -99.1 +80.0 -86.7 +77.0 -77.0 +69.1 -69.1 Custom Size 22.131 -24.963 +80.0 -130.0 +80.0 -130.0 +80.0 -120.0 +80.0 -104.0 +80.0 -9Z2 +80.0 -82.1 +74.2 -74.2 1 +66.3 -66.3 Standard Pro\Aew 20.194-22.130 +80.0 -130.0 +80.0 -130.0 +80.0 -112.0 +80.0 -99.1 +80.0 -87.5 +79.2 -79.2 +72.0 -72.0 +62.5 -62.5 00 49" Custom Size 18.131 -20.193 +80.0 -130.0 +80.0 -130.0 +80.0 -105.0 +80.0 -94.5 +80.0 -83.5 +76.8 -76.8 +69.7 -69.7 +60.6 -60.6 3/16"ANNEALED W Custom Size 16.131 -18.130 +80.0 130.0 +80.0 127.0 +80.0 99.8 +80.0 90.7 +80.0 81.2 +74.8 74.8 +67.7 67.7 +59.6 59.6 GLASS w p ?j nab Custom Size 14.131 -16.130 +80.0 -130.0 +80.0 -120.0 +80.0 -94.5 +80.0 -87.3 +79.0 -79.0 +72.9 -72.9 +65.8 -65.8 +58.7 -58.7 30 0 �o o O Shortest LU 12.464-14.130 +80.0 -130.0 +80.0 -112.0 +80.0 -89.1 +80.0 -82.3 +76.9 -76.9 +70.5 -70.5 +64.2 -64.2 +57.6 -57.6 + LO o a}oQ 0 Q L Equal-lite 25.777 +80.0 -130.0 +80.0 -130.0 +80.0 -129.0 +80.0 -110.0 +80.0 -97.2 +80.0 -84.9 +75.4 -75.4 +67.5 -67.5 26 O 'T -w O 1/2"NOM. co a Custom Size 24.131 -25.776 +80.0 -130.0 +80.0 -130.0 +80.0 -120.0 +80.0 -104.0 +80.0 -92.2 +80.0 -82.1 +73.8 -73.8 +66.0 -66.0 GLASS BITE � J O a Qi W O w~° Standard Pro\iew 20.844-24.130 +80.0 -130.0 +80.0 -130.0 +80.0 -109.0 +80.0 -96.7 +80.0 -85.4 +78.0 -78.0 +70.8 -70.8 +61.5 -61.5 EXTERIOR Z LL 0 oo= a Custom Size 20.131 -20.843 +80.0 -130.0 +80.0 -130.0 +80.0 -105.0 +80.0 -94.5 +80.0 -83.5 +76.8 -76.8 +69.7 -69.7 +60.6 -60.6 2 L oN c� 50-5/8" � � z 8 ~ ~ Custom Size 18.131 -20.130 +80.0 -130.0 +80.0 -127.0 +80.0 -99.8 +80.0 -90.7 +80.0 -81.2 +74.8 -74.8 +67.7 -67.7 +59.6 -59.6 74 W U J J uMaaQ ON Custom Size 16.131 -18.130 +80.0 -130.0 +80.0 -120.0 +80.0 -94.5 +80.0 -87.3 +79.0 -79.0 +72.9 -72.9 +65.8 -65.8 +58.7 -58.7 I- Z � =Q J 34 o W cD Q �M a Custom Size 14.131 -16.130 +80.0 -130.0 +80.0 -112.0 +80.0 -89.1 +80.0 -82.3 +76.9 -76.9 1 +70.5 -70.5 +64.2 -64.2 +57.6 -57.6 r- > H Shortest 12.464-14.130 +80.0 130.0 1 +80.0 108.0 +80.0 86.4 1 +80.0 80.6 +75.8 75.8 +69.3 69.3 +63.5 63.5 +57.0 57.0 GLASS TYPE 3 Z °' ° Z Equal-lite 31.964 +80.0 -130.0 +80.0 -130.0 1 +80.0 -105.0 +80.0 -94.5 +80.0 -83.5 +75.4 -75.4 +66.1 -66.1 +58.6 -58.6 - N Custom Size 28.131 -31.963 +80.0 -130.0 +80.0 -120.0 +80.0 -94.5 +80.0 -87.3 +79.0 -79.0 +72.9 -72.9 +64.1 -64.1 +56.7 -56.7 Z ILL Standard Promew 25.794-28.130 +80.0 -130.0 +80.0 -108.0 +80.0 -86.4 +80.0 -80.6 +75.8 -75.8 +69.3 -69.3 +63.5 -63.5 1 +57.0 -57.0 0 Custom Size 24.131 -25.793 +80.0 -130.0 +80.0 -105.0 +80.0 -83.5 +79.0 -79.0 +74.8 -74.8 +68.2 -68.2 +62.3 -62.3 +56.5 -56.5 (D = c7 63" Custom Size 22.131 -24.130 +80.0 -130.0 +80.0 -99.8 +80.0 -80.2 +75.9 -75.9 +71.4 -71.4 +65.9 -65.9 +60.6 -60.6 +55.4 -55.4 ® 0) J Custom Size 20.131 -22.130 +80.0 -130.0 +80.0 -93.4 +76.8 -76.8 +72.9 -72.9 +68.2 -68.2 +63.8 -63.8 +58.9 -58.9 +54.0 -54.0 = Z aayS Custom Size 18.131 -20.130 +80.0 -130.0 +80.0 -88.6 1 +73.4 -73.4 +69.5 -69.5 +65.1 -65.1 +61.1 -61.1 +57.3 -57.3 +52.1 -52.1 Custom Size 16.131 -18.130 +80.0 -129.1 +80.0 -83.7 +69.7 -69.7 +65.8 -65.8 +62.3 -62.3 +58.9 -58.9 1 +55.7 -55.7 +50.8 -50.8 Q LL Shortest 13.194*-16.130 +80.0 -125.5 +75.8 -75.8 +63.7 -63.7 +61-1 1 -61.1 +58.9 -58.9 +55.9 -55.9 +52.3 -52.3 1 +48.6 -48.6 1 O D J O Equal-lite 38.464 +80.0 -130.0 +80.0 -108.0 +8&0 -86.4 +80.0 -80.6 +75.8 -75.8 +69.3 -69.3 +60.7 -60.7 +53.2 -53.2 Z m Custom Size 36.131 -38.463 +80.0 -130.0 +80.0 -102.0 +80.0 -81.8 +77.4 -77.4 1 +73.1 -73.1 +67.0 -67.0 +60.0 -60.0 +52.5 -52.5 Lu _ Custom Size 34.131 -36.130 +80.0 1 -130.0 +80.0 -96.7 +78.5 -78.5 +74.4 -74.4 +69.8 -69.8 +64.8 -64.8 +59.7 -59.7 +52.7 -52.7 U J d U) 76" Standard Pro\iew 30.994-34.130 +80.0 -130.0 +80.0 -88.6 +73.4 -73.4 +69.5 -69.5 +65.1 -65.1 +61.1 -61.1 +57.3 -57.3 +52.1 -52.1 Q asaQ sauaS Custom Size 30.131 -30.993 +80.0 -130.0 +80.0 -86.2 +71.6 -71.6 +67.7 -67.7 +63.6 -63.6 +60.0 -60.0 +56.5 -56.5 +51.4 -51.4 a}!1 Custom Size 28.131 -30.130 1 +80.0 -127.8 +80.0 -81.0 +67.8 -67.8 +64.0 -64.0 +61.4 -61.4 +57.9 -57.9 +54.5 1 -54.5 1 +50.1 -50.1 Shortest 26.194*-28.130 +80.0 -125.5 +75.8 -75.8 +63.7 -63.7 +61.1 -61.1 +58.9 -58.9 +55.9 -55.9 +52.3 -52.3 +48.6 -48.6 Equal-lite 42.464 +80.0 -130.0 +80.0 -96.7 +78.5 -78.5 +74.4 -74.4 +69.8 -69.8 +64.8 -64.8 +58.9 -58.9 +51.1 -51.1 � oV LYNN 84" Custom Size 38.131 -4Z463 +80.0 130.0 +80.0 86.2 +71.6 71.6 +67.7 67.7 +63.6 63.6 +60.0 60.0 +56.5 56.5 +50.4 50.4 \�\��� \,ICENg '•r'/��l Standard ProNhew 34.194*-38.130 +80.0 125.5 +75.8 -75.8 +63.7 63.7 +61.1 61.1 +58.9 -58.9 1 +55.9 -55.9 +52.3 -52.3 +48.6 -48.6 Q ,•' )3 *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 _ NO. 58705 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 = _ MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 Q' 0 '. STATE OF �44j\ F(ORID P.• 1)TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS, SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. i� s/ 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. /�////I 3)FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. A.LYNt ULLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 TABLE 4: Bottom Sash Sash Height Design Pressure(Ibs/ft2)for Glass Type 4 Description Range(in) Tip to Tip Width for Given Range 18" 25" 33" 37" 41" 45" 49" 53-1/8" � 13/16"NOM. 24" Equal-lite 12.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 GLASS STACK Equal-lite 15.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 31" Standard Proview 12.994-15.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 AIRSPACE Shortest 12.464-12.993 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 GLASS ANNEALED GLASS ,t PP'T-vad na M 6, Equal-lite 19.652 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 Ft n, p Standard Proview 15.944-19.651 +80.0 1 -130.0 1 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 1 +80.0 -130.0 +80.0 -122.0 +80.0 -112.0 31 74 rr 38-3/8" Custom Size 15.131-15.943 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.05 Custom Size 14.131-15.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.6 25 OR 5B 1/2"NOM. Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -124.0 GLASS BITE Equal-lite 22.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -117.7 EXTERIOR Custom Size 20.131-22.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.3 +80.0 -112.5 a Standard Promew 18.594-20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.1 +80.0 -116.0 45" Custom Size 16.131-18.593 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -126.0 +80.0 -112.5 70-73 35 OR 35B Custom Size 15.131-16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -127A +80.0 -110.7 Custom Size 14.131-15.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.5 +80.0 -109.1 GLASS TYPE 4 Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 1 -121.9 +80.0 1 -107.3 Equal-lite 24.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -123.3 +80.0 -110.6 Custom Size 22.131 -24.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.7 +80.0 -106.3 Standard Proview 20.194-22.130 +80.0 1 -130.0 1 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 1 -130.0 +80.0 -121.3 +80.0 -108.6 _O 49" Custom Size 18.131-20.193 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.8 +80.0 -108.1 Z ) Custom Size 16.131 -18.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.9 +80.0 -107.3 � � O nab Custom Size 14.131 -16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.4 +80.0 -105.7 0 �0 0 w LO Shortest 12.464-14.130 +80.0 -130.0 +80.0 130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -126.9 +80.0 -115.6 +80.0 -103.7 �- o aaoQ O Q c uJ Equal-lite 25.777 +80.0 130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.6 +80.0 -108.1 NT - w O = Custom Size 24.131-25.776 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.1 +80.0 105.7 0 co C u) Z O J 00 a W 0 o Standard Proview 20.844-24.130 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 116.7 +80.0 104.3 Z LL 0 02 = O o Custom Size 20.131 -20.843 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.1 +80.0 -107.4 = 1JJ N Z 50-5/8" � � 8 Custom Size 18.131 -20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.8 +80.0 -107.0 W U 0 (D J -� uM0j(7 JON Custom Size 16.131 -18.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.4 +80.0 -105.7 H W Q JQ Custom Size 14.131 -16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 1 +80.0 -126.9 +80.0 -115.6 +80.0 -103.7 Or > r H Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -124.7 +80.0 -114.3 +80.0 -102.6 Z CY) EL Z_ O Equal-lite 31.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.6 +80.0 -105.7 1 +76.2 -93.8 O Custom Size 28.131 -31.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -117.5 +80.0 -102.6 +73.7 -90.8 Z LL Standard Proview 25.794-28.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.8 +80.0 -104.6 +75.2 -92.6 D O Custom Size 24.131 -25.793 +80.0 -130.0 1 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.8 +80.0 -106.3 +76.4 -94.0 rn _ 63" Custom Size 22.131 -24.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -128.5 +80.0 -118.6 +80.0 -107.4 +77.0 -94.8 ® N J Custom Size 20.131 -22.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -122.8 +80.0 -114.8 +80.0 -106.0 +78.3 -96.3 * 0 = Z aauS Custom Size 18.131 -20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.1 +80.0 -117.2 +80.0 -110.0 +80.0 -103.1 +79.9 -93.8 ♦- Custom Size 16.131 -18.130 +80.0 -130.0 +80.0 -130.0 +80.0 -125.5 +80.0 -118.4 +80.0 -112.1 +80.0 -106.0 +80.0 -100.3 +80.0 -91.4 Q � Shortest 13.194*-16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -114.7 +80.0 -110.0 +80.0 -106.0 +80.0 -100.6 +80.0 -94.1 +80.0 -87.8 0O J O Equal-lite 38.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -112.5 +78.9 -97.1 +69.1 -85.1 Z m Custom Size 36.131-38.463 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -111.7 +78.1 -96.1 +68.2 -84.0 w _ Custom Size 34.131-36.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.6 +80.0 -112.1 +78.4 -96.5 +68.5 1 -84.4 U J 0_ U) 76" Standard Proview 30.994-34.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.1 +80.0 -117.2 +80.0 -110.0 +78.7 -96.9 +68.7 -84.5 Q Custom Size 30.131 -30.993 +80.0 -130.0 +80.0 -130.0 +80.0 -128.9 +80.0 -121.9 +80.0 -114.5 +80.0 -108.0 +80.0 -99.0 +70.2 -86.4 a}1 asaQ sauaS Custom Size 28.131-30.130 +80.0 -130.0 +80.0 -130.0 +80.0 -122.0 +80.0 -115.2 +80.0 -110.5 1 +80.0 -104.2 +80.0 -98.1 +70.4 -86.6 \t ! l I 1 1 1 1///' Shortest 26.194*-28.130 +80.0 -130.0 +80.0 -130.0 +80.0 -114.7 +80.0 -110.0 +80.0 -106.0 +80.0 -100.6 +80.0 -94.1 +71.5 -87.8 '�iz, Equal-lite 42.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.6 +80.0 -110.4 +76.5 -94.2 +66.5 81.8 ` `� •.�;CE��S•. 84" Custom Size 38.131-42.463 +80.0 -130.0 +80.0 -130.0 +80.0 -128.9 +80.0 -121.9 +80.0 -114.5 +80.0 -108.0 +75.8 -93.3 +65.5 -80.6 F '•,l� r Standard Promewl 34.194*-38.130 +80.0 -130.0 +80.0 -130.0 +80.0 -114.7 1 +80.0 -110.0 +80.0 -106.0 +80.0 1 -100.6 +76.8 -94.1 +66.3 -81.6 *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 No. 58705 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 _ �j _ MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG, RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 %S .TF ��\ 'c`ORIDP 1)TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 1ONAL 2)FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 3)FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. A.LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 TABLE 5: Bottom Sash Sash Height Design Pressure(lbs/ft)for Glass Types 5-8 Description Range(in) Tip to Tip Width 1/8"TEMPERED for Gi\,en Range GLASS 18" 25" 33" 37" 41" 45" 49" 53-1/8" 24" Equal-lite 12.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +8&0 -130.0 30 Equal-lite 15.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 26 31" Standard Proview 12.994-15.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 (G�LASS M. Shortest 12.464-12.993 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 BITE „f, q ..< u ng tt t Equal-lite 19.652 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 EXTERIOR Standard Pro\Aew 15.944-19.651 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -122.0 +80.0 -112.0 :azte 38-3/8" Custom Size 15.131 -15.943 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 74 Custom Size 14.131 -1&130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 Ives 3 D,-e o I 34 Shortest 12.464-14.130 +80.0 130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 GLASS TYPE 5 Equal-lite 22.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -117.7 Custom Size 20.131 -22.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.3 +80.0 -112.5 13/16"NOM. Standard Promew 18.594-20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.1 +80.0 -116.0 I GLASS STACK 45" Custom Size 16.131 -18.593 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -126.0 1 +80.0 -113.7 Custom Size 15.131 -16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.6 AIRSPACE 2 Custom Size 14.131 -15.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.5 1/8"TEMPERED GLASS Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 1 -119.7 cr 31 74 Equal-lite 24.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -123.3 +80.0 -110.6 Custom Size 22.131 -24.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.7 +80.0 -106.3 25 OR 5B 1/2"NOM. Standard Provew 20.194-22.130 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.3 +80.0 -108.6 0 Y 49" Custom Size 18.131 -20.193 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.8 +80.0 -108.1 EXTERIOR GLASS BITE LU z U) Custom Size 16.131 -18.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -123.5 +80.0 -110.3 a � w O Custom Size 14.131 -16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.8 +80.0 -112.1 0 N o CO U) = Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.2 +80.0 -114.9 70-73 >- � a oQ O o �w 0 Q .5 Equal-lite 25.777 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.6 +80.0 -108.1 35 OR 356 0 � z U) O GLASS TYPE 6 O W U) 2_ Custom Size 24.131 -25.776 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.1 +80.0 -105.7 O J O cr Z ZO .2 Standard Pro\Aew 20.844-24.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -116.7 +80.0 -104.3 z U_ 0 _ I LU 0 n Custom Size 20.131 -20.843 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.1 +80.0 -107.4 2 L N Z 8 ti 50-5/8" 3/16"TEMPERED U ( O O 4 Custom Size 18.131 -20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.8 +80.0 -107.0 LLJ W (6 J J UMOJQ GLASS °N Custom Size 16.131 -18.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.7 +80.0 -108.5 I- W ¢ Q HMO Custom Size 14.131 -16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -124.2 +80.0 -110.5 30 O� > } d U) Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -127.8 +80.0 -113.4 26 Z O Z Equal-lite 31.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.6 +80.0 -105.7 +76.2 -93.8 1/2"NOM. Custom Size 28.131 -31.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -117.5 +80.0 -102.6 +73.7 -90.8 GLASS BITE Z LL EXTERIOR Standard Pro�iew 25.794-28.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.8 +80.0 -104.6 +75.2 -92.6 � � D O Custom Size 24.131 -25.793 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.8 +80.0 -106.3 +76.4 -94.0 CO r L0 63" Custom Size 2Z 131 -24.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -123.3 +80.0 -107.4 +77.0 -94.8 74 ® N J Custom Size 20.131 -22.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -126.0 +80.0 -109.4 +78.3 -96.3 0 34 Z as 1 US Custom Size 18.131 -20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.4 +80.0 -112.0 +79.9 -98.3 GLASS TYPE 7 Custom Size 16.131 -18.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -115.1 +80.0 -100.7 Q Shortest 13.194*-16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.2 +80.0 -118.8 +80.0 -103.5 0 D J o Equal-lite 38.464 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 130.0 +80.0 130.0 1 +80.0 112.5 +78.9 97.1 +69.1 85.1 13/16"NOM. z Q Custom Size 36.131 -38.463 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -111.7 +78.1 -96.1 +68.2 -84.0 GLASS STACK LU _ Custom Size 34.131 -36.130 +80.0 1 -130.0 +80.0 -130.0 1 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -112.1 +78.4 -96.5 +68.5 -84.4 U J 0- U) 76" Standard Pro\Aew 30.994-34.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -113.0 +78.7 -96.9 +68.7 -84.5 AIRSPACE 3/16"TEMPERED Q 0 Custom Size 30.131 -30.993 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 1 -115.2 +80.0 -99.0 +70.2 -86.4 GLASS a 311 asaa sauaS Custom Size 28.131 -30.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -115.9 +80.0 -99.5 +70.4 -86.6 Shortest 26.194*-28.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -117.9 +80.0 -101.3 +71.5 -8&0 31KLASS t�\\ ®�\! LYNX�B rrrr Equal-lite 42.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -110.4 +76.5 -94.2 +66.5 -81.8 �\ 't.`a \CEN 84" Custom Size 38.131 -42.463 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -110.1 +75.8 -93.3 +65.5 -80.6 25 OR 5B •' L �' Standard Provew 34.194*-38.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -111.1 +76.8 44.5 +66.3 -81.6 EXTERIOR _ No. 58705 MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 r�MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG, RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 OR35B 0 S ATE OF (� � GLASS TYPE 8 1)TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. srrr/ �ONAL\ ``�� \a 2) FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. 3) FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. A.LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 TABLE 6: Anchor Quantities Required for Tip to Tp Width "Through-Frame"Installation 18" 25" 33" 37" 41" 45" 49" 53-1/8" using Glass Ty es 1-3 Jamb Jamb Jamb Jamb Jamb Jamb Jamb Jamb Bottom Sash g a g g 2 a � -o 2 � a � � -00 Descr tion Sash Height 0 � T 0 3 T) 0 3 a) 0 3 a) 0 3 a`) 0 3 a) 0 3 a) 0 3 p Range(in) o o = o o = o _ 'o o = o o = o o = o o = o o = for Gi\en Range -0 a a a) -0 0 -0 a -0 0 a) -0 a) n a) TABLE 6b: ¢ m ¢ m ¢ co ¢ m ¢ m ¢ m ¢ m ¢ m Glass 24" Equal-lite 12.464 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 Type Description(Listed from Exterior to Interior) Equal-lite 15.964 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 as cat"�t;ar 1** 1/8"Annealed 31" Standard Pro\iew 12.994-15.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 2 13/16"IG: 1/8"Annealed Cap,Airspace, 1/8"Annealed L � ) Av 'ace-, Shortest 12.464-12.993 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3/16"Annealed r $ + Equal-lite 19.652 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 _ `�TIP TO TIP SIZE FOR WINDOW USING GLASS TYPE 1 IS Vf•� {� ��e�'�°G `"•�` t Standard Pro\iew 15.944-19.651 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 LIMITED TO 53-1/8"X 76". 38-3/8" Custom Size 15.131-15.943 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 14.131 -15.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Shortest 12.464-14.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Equal-lite 22.964 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 20.131 -22.963 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Standard Pro\iew 18.594-20.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 > m 45" Custom Size 16.131 -18.593 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 15.131 -16.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 $22 2 2 2 2 2 2 Custom Size 14.131-15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 3 2 2 3 2 2 b 0 Y Equal-lite 24.964 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 W z U) Custom Size 22.131 -24.963 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 � wOStandard Promew 20.194-22.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 0 �o Op 0 49" Custom Size 18.131-20.193 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 o> a/oQ Q Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 O F W O Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 J J O a X Z O Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 LL 0 oo= W 0 .5 Equal-lite 25.777 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 LLI N E Z �8 r = Custom Size 24.131 -25.776 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 W U � 0 J uMoaQ n ON y Standard Promew 20.844-24.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 W L¢ Q DMQ a Custom Size 20.131-20.843 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 > r F-- 50-5/8" O ao to Custom Size 18.131 -20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Z Z Custom Size 16.131 -18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 - W N Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Z J LL Z m LL Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Equal-lite 31.964 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 GLASS TYPE 1: Custom Size 28.131 -31.963 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-37.536 ® rn J O Standard Proview 25.794-28.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-36.536 (� F_ MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-37.951 = Z ways Custom Size 24.131 -25.793 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Z Q 63" Custom Size 22.131 -24.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG, RADIUS TOP WINDOWS IS: BUCK HEIGHT-36.951 : U � Custom Size 20.131 -22.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 *GLASS TYPE 2&3: u D Of ¢O MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 O Z O Custom Size 18.131 -20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 H _ O MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 Custom Size 16.131 -18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 L _ ~ MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 U : U 2 Shortest 13.194*-16.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 2 4 2 2 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG, RADIUS TOP WINDOWS IS: BUCK HEIGHT-48.806 J Z in Equal-lite 38.464 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 Q Q Custom Size 36.131 -38.463 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 ai tl asap sauas Custom Size 34.131-36.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 76" Standard Proview 30.994-34.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 ���\�&Y LY/ At Custom Size 30.131-30.993 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 �� � Custom Size 28.131-30.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 v LICENSE .Clio Shortest 26.194*-28.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 2 4 2 2 Equal-lite 42.464 3 4 1 3 4 1 3 4 1 3 4 2 77 2 3 4 2 3 4 2 3 4 2 _ No. 58705 84" Custom Size 38.131-42.463 3 4 1 3 4 1 3 4 1 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 1)TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM s THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. Standard PrmAew 34.194*-38.130 4 3 1 4 3 1 4 3 1 4 3 2 4 3 2 4 3 2 4 3 2 4 3 2 = 2)FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. ® SATE OF 3)FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE �� °cI0RIDP• \ � RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. >// [VAL e'\\\\\ 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF A.LYNN MILLER,P.E. +65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 TABLE 7: Anchor Quantities Required for Tip to Tip Width "Through-Frame"Installation 18" 25" 33"' 37" 41" 45" 49"' 53-1/8" using Glass Ty s 4-8 Jamb Jamb Jamb Jamb Jamb Jamb Jamb Jamb Bottom Sash a o g o o g o 2i 5 a 2i g o 2 2 a Description Sash Height o 3 aa) o 3 Q) a)g. 3 a) 0g. 3 Q) a) 3 aa) a) 3 aa, 3 a�i a) 3 aai Range(in) o o = o o = o o = o = o o = o o = o o = o o = for Given Range _6 a) s a) a ro -o a) a a) -o m .8 a) -0 a> TABLE 7b: ¢ m ¢ m ¢ m ¢ m ¢ m ¢ m ¢ m ¢ m 24" E ual-lite 12.464 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 Glass Description(Listed from Exterior to Interior) .. q Type -1 m yet ns CAIP=fs.Y°.119 wi€h th*,_ Equal-lite 15.964 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2t 4 13/16"IG: 3/16"Annealed Cap,Airspace, 3/16"Annealed s 31" Standard Proview 12.994-15.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 5 1/8"Tempered -)A' Shortest 12.464-12.993 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 6 13/16"IG: 1/8"Tempered Cap,Airspace, 1/8"Tempered 'mod *'. Equal-lite 19.652 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 7 3/16"Tempered Standard Proview 15.944-19.651 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 8 13/16"IG: 3/16"Tempered Cap,Airspace, 3/16"Tempered 38-3/8" Custom Size 15.131 -15.943 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Custom Size 14.131 -15.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Shortest 12.464-14.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 3 Equal-lite 22.964 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 Custom Size 20.131 -22.963 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 Standard Proview 18.594-20.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 2 3 3 m 45" Custom Size 16.131 -18.593 2 2 dl 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 3 Custom Size 15.131 -16.130 2 2 2 2 12 2 2 2 2 2 2 2 2 2 2 2 3 2 3 3 2 3 Custom Size 14.131 -15.130 2 2 2 2 12 2 2 2 2 2 2 2 2 3 2 2 3 2 3 3 2 3 Shortest 12.464-14.130 3 2 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 00 Y Equal-lite 24.964 2 2 1 2 2 1 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 ; Z U) Custom Size 22.131 -24.963 2 2 1 2 2 1 1 2 2 21 2 3 2 2 3 2 2 3 21 2 3 2 2 3 2 w O > nab Standard Proview 20.194-22.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 3 2 3 3 0 o 0p U 49" Custom Size 18.131 -20.193 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 3 3 21 3 3 3 2 3 3 > a}o0 O ' Custom Size 16.131 -18.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 O N z N O O �.,� Custom Size 14.131 -16.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 J Z Z O J O IL cn Shortest 12.464-14.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 Z I L. C) _ LU 0 Equal-lite 25.777 2 2 1 2 2 1 1 2 1 2 1 21 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 = Ld 2 Z 48 = Custom Size 24.131 -25.776 2 2 dI 2 2 1 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 W U @ J J uMoaQStandard Proview 20.844-24.130 2 2 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 H Z NT _¢ JoN _ C� Q DMO Custom Size 20.131 -20.843 2 2 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 3 2 3 3 C) � r50-5/8" Custom Size 18.131 -20.130 3 2 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 3 3 3 2 3 C1 Z O Z_ Custom Size 16.131 -18.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 J C14 Custom Size 14.131 -16.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 Z m LL Shortest 12.464-14.130 3 2 1 3 2 1 3 2 2 1 3 2 2 3 2 2 3 2 3 3 2 3 3 2 1 3 1 < O Equal-lite 31.964 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 rn _ Custom Size 28.131 -31.963 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 ® rn J Standard Proview 25.794-28.130 3 2 1 3 2 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 3 3 3 O Z Z aays Custom Size 24.131 -25.793 3 2 1 3 2 1 3 2 2 3 3 2 3 3 2 3 3 3 3 3 3 3 3 3 Z Q 63" Custom Size 22.131 -24.130 3 2 1 3 2 1 3 2 2 3 2 2 3 3 2 3 3 3 3 3 3 3 3 3 Custom Size 20.131 -22.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 4 3 3 3 3 3 3 2 3 00 O Custom Size 18.131 -20.130 3 2 1 3 2 1 3 2 2 3 2 2 4 2 2 4 2 3 4 2 3 3 2 3 Z O Custom Size 16.131 -18.130 3 2 1 3 2 1 3 2 2 4 2 2 4 2 2 4 2 3 4 2 3 4 2 3 w 5 U 2 Shortest 13.194*-16.130 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 3 4 2 3 4 2 3 U J Z (n Equal-lite 38.464 3 3 1 3 3 1 3 3 2 3 1 4 2 3 1 4 2 3 4 2 3 4 2 3 3 2 Q Q Custom Size 36.131 -38.463 3 3 1 3 3 1 3 3 2 3 4 2 3 4 2 3 4 2 3 4 2 3 3 2 a}1 asao sauas Custom Size 34.131 -36.130 3 3 1 3 1 3 1 3 3 2 3 3 2 3 4 2 3 4 2 3 3 2 3 3 2 //// 76" Standard Proview 30.994-34.130 3 3 1 3 3 1 3 3 2 3 3 2 4 4 2 3 3 2 3 3 2 3 3 2 `; t LYNX Custom Size 30.131 -30.993 3 3 1 3 3 1 3 3 2 3 3 2 4 3 2 4 3 2 3 3 2 3 3 3 Fs tom Size 28.131 -30.130 3 3 1 3 3 1 3 3 2 4 3 2 4 3 2 4 3 2 3 3 3 3 3 3ortest 26.194*-28.130 4 2 1 4 2 1 4 3 2 4 3 2 4 3 2M44 4 3 3 4 3 3 IVO. 58705 .13 Equal-lite 42.464 3 4 1 3 4 1 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 84" Custom Size 38.131 -42.463 3 4 1 3 4 1 3 4 2 3 4 2 4 4 2 3 4 2 3 4 2 1)TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. - TJ Standard Proview 34.194*-38.130 4 3 1 4 3 1 4 3 2 4 4 2 4 4 2 4 4 2 4 3 2 * 411 MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 2)FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. '• WTE � MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 i `•."40R,pP MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 3)FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE /O MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. °e// t A �\��� 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF A. LYNN MILLER,P.E. +65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 INSTALLATION DETAILS FOR FLANGE FRAMES INSTALLATION OPTION 2 INSTALLATION OPTION 3 INSTALLATION ANCHORED THROUGH FRAME ANCHORED THROUGH FRAME AND 1X EDGE DISTANCE DIRECTLY INTO CONCRETE/CMU. BUCKSTRIP INTO CONCRETE/CMU. OPTION 1 -� --- SEE NOTE 2,THIS SHEET. � -�--- --T--� EMBEDMENT ANCHORED THROUGH - EMBEDMENT FRAME INTO 2X WOOD f 1/4"MAX SHIM 1/4"MAX SHIM If FRAME OR BUCKSTRIP. ° I ( EMBED- ( 4 SASH VISIBLE 17 SEE NOTE 2,THIS SHEET. EDGE l MENT DISTANCE ° ° � �7 EDGE ° LIGHT WIDTH 0-ppvM4 PA DISTANCE 1 a ` 1/4"MAX SHIM i 19 + 'k0X ° FIXED VISIBLE ° n §4_ s , 26 L-- - - L--J I� LIGHT WIDTH 1 SEE TABLE e NOTE B,FOR ° 18 HEAD TYPE TYP.ANCHOR TYPE, ° ° 44 FIXED EMBEDMENTAND VISIBLE EDGE DISTANCE PER LIGHT SUBSTRATE,SEE HEIGHT 31 5 OR 5B TABLE 8. j TIP TO TIP WIDTH TYP.ANCHO\TYPE, 32 EMBEDME b 00 2 TYP.ANCHOR TYPE, EXTERIOR HORIZONTAL SECTION A-A EDGE DISTAN � Z 45 EMBEDMENT AND EDGE SUBSTRATE,SEE w O °a� DISTANCE PER SUBSTRATE, TABLE 8. o 14 SEE TABLE 8. I� 1/4"MAX.SHIM O N z W a}oQ O Q VISIBLE LIGHT FORMULAS: p � W O 46 55 DADE APPROVED MULLION,FBC (SHOWN FOR HI-RISE SILL;SEE -% J O d u) Z O COMPLIANT ALUMINUM/STEEL FRAMING SHEET 10 FOR STANDARD SILL) L- O �_ W � 43 OR STEEL STUD. MAY BE VERTICAL OR 1E TIP LLI CD N CD TO HORIZONTAL. SEE SUBSTRATE ' � Z e 13 WIDTH U (� O OO J unnoa TIP g3 USE EITHER 1 PROPERTIES,TABLE 8. @ SASH&FIXED LITE:TIP TO TIP WIDTH-5.12" Z F-LLI ¢ J �NNa HEIGHT SWEEP LATCH @ HEIGHT(EQUAL-LITE) O0 > ~ MIDSPAN OR 2 O CL L7 BOTTOM LOCKS INSTALLATION TIP TO TIP HEIGHT/2-3.73" Z o Z OPTION 4 HEIGHT(PROVIEW) SASH > ANCHORED THROUGH Z LL VISIBLE >> FRAME INTO METAL @FIXED LITE:TIP TO TIP HEIGHT/2+3.78" = O LIGHT @SASH:TIP TO TIP HEIGHT/2-11.93" rn 2 Z 00 HEIGHT ® N W HEIGHT(CUSTOM SASH) C @FIXED LITE:TIP TO TIP HEIGHT-SASH HEIGHT-3.55" Z U ways @SASH:SASH HEIGHT-4.60" _ U) �W EXTERIOR TABLE 8: U- X oa W O 33 Anchor Substrate Min. Edge Min. Embedment NOTES: Z co 10 Distance w = 15 P.T. Southern Pine (SG=0.55) 9/16" 1-3/8" 1)USE ONLY SUBSTRATE-APPROPRIATE ANCHORS LISTED ON U J J U) OPTIONAL HI-RISE #12 Steel, TABLE 8. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS.ANY Q U_ SILL SHOWN.SEE Aluminum, 6063-T5 min. 3/8" 0.063" INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF aµil asaa sauas 1"WEEP 42 SHEET 10 FOR 18-8 or 410 THE WINDOW. A36 Steel 3/8 0.063 NOTCH AT STANDARD SILL. SS Screw EACH END Steel Stud, Gr. 33 min. 3/8" 0.045" (18 Ga) 2)MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE SHIM 410 SS Concrete (min. 3.35 ksi) 1" 1-3/4" 8.ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE `�°• �10ENS 1/4" CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL °'•;f�, Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD BUCKS CreteFlex P.T. Southern Pine (SG-0.55) 1" 1-3/8" DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER. 1X AND 2X BUCKS N®. 58705 (WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER NO ANCHORS Concrete (min. 2.85 ksi) 1" 1-3/8" LOADS TO THE STRUCTURE.WOOD BUCK DESIGN AND REQUIRED IN ° 1/4" Steel Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR e Ultracon ARCHITECT OF RECORD. C� °. SATE OF e FLANGE OR ° Southern Pine (SG=0.55)P.T. 1" 1-3/8" EQUAL-LEG ORtD�.•° A MIN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. 3)VISIBLE LIGHT WIDTH OR HEIGHT(ALSO REFERRED TO AS r ° '•••.•• `\ FRAME SILLS )B) USE ONLY FLATHEAD ANCHORS IN JAMBS, PAN/HEX/FLAT HEAD TYPE IS DAYLIGHT OPENING)IS MEASURED FROM BEADING TO BEADING. sJ f NIAL \\\\ l! i VERTICAL SECTION B-B ALLOWABLE FOR ANCHORS IN THE HEAD. 6 I I V t 0 C)"UNGROUTED CMU"VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. A. LYNN MILLER,P.E. P.E.#58705 INSTALLATION DETAILS FOR EQUAL-LEG FRAMES INSTALLATION OPTION 2 INSTALLATION OPTION 3 INSTALLATION ANCHORED THROUGH FRAME ANCHORED THROUGH FRAME AND 1X EDGE DISTANCE DIRECTLY INTO CONCRETE/CMU. BUCKSTRIP INTO CONCRETE/CMU. OPTION 1 — -- ------ SEE NOTE 2,THIS SHEET. ANCHORED THROUGH r j. ► EMBEDMENT �---� EMBEDMENT FRAME INTO 2X WOOD 1/4"MAX SHIM 1/4"MAX SHIM I►— —� FRAME OR BUCKSTRIP. EDGE SEE NOTE 2,THIS SHEET. EMBED- ( SASH VISIBLE 17 MENT LIGHT WIDTH EDGE ° DISTANCE DISTANCE ° a 140 -F— ��2"1/4"MAX SHIM 19 - . � '. I FIXED VISIBLE a 26 L_-- LIGHT WIDTH - .l SEE TABLE 11 r 3 NOTE B,FOR ° e IC 30 18 HEAD TYPE TYP.ANCHOR TYPE, ° 44 FIXED EMBEDMENT AND VISIBLE EDGE DISTANCE PER ° ° ° LIGHT SUBSTRATE,SEE HEIGHT 31 TABLE 8. 5 OR 5B 6 - BUCK WIDTH TYP.ANCHO\TYPE, 32 EXTERIOR EMBEDME 0TYP.ANCHOR TYPE, HORIZONTAL SECTION A-A EDGE DISTAN � ? (>n 45 EMBEDMENT AND EDGE SUBSTRATE,SEE W W O > a� DISTANCE PER SUBSTRATE, TABLE 8. 0 o SEE TABLE 8. r o W a�oQ O Q 14 VISIBLE LIGHT FORMULAS: OO M F W O 1/4"MAX.SHIM 46 55 (SHOWN FOR HI-RISE SILL;SEE 0 _j O a� Z ZO SHEET 10 FOR STANDARD SILL) Z LL O _ W � co 43 DADE APPROVED MULLION,FBC = W T N E Z 48 BUCK 13 COMPLIANT ALUMINUM/STEEL FRAMING WIDTH W — 00 O o0 uMoaQ HEIGHT 63 USE EITHER 1 OR STEEL STUD. MAY BE VERTICAL OR @SASH&FIXED LITE: BUCK WIDTH-4.12" H Lu Q J 5M0 SWEEP LATCH @ HORIZONTAL. SEE SUBSTRATE HEIGHT(EQUAL-LITE) O0 MIDSPAN OR 2 PROPERTIES,TABLE 8. BUCK HEIGHT/2-3.23" O Z O o Z BOTTOM LOCKS 0 _ N INSTALLATION SASH HEIGHT(PROVIEW) O VISIBLE EQUAL OPTION 4 @FIXED LITE: BUCK HEIGHT/2+4.28" D O O LIGHT LEG/BOX ANCHORED THROUGH @SASH: BUCK HEIGHT/2-11.43" m 2 O HEIGHT FRAME FRAME INTO METAL ® N W ~ _ SHOWN HEIGHT(CUSTOM SASH) W 11 @FIXED LITE: BUCK HEIGHT-SASH HEIGHT-2.55" Z U) ways @SASH:SASH HEIGHT-4.60" ? X EXTERIOR TABLE 8: W O¢ 0 O a 33 Anchor Substrate Min. Edge Min. Embedment NOTES: 1- 12 Distance w _ 15 J P.T. Southern Pine (SG=0.55) 9/16" 1-3/8" 1)USE ONLY SUBSTRATE-APPROPRIATE ANCHORS LISTED ON U C3 (q OPTIONAL HI-RISE #12 Steel, TABLE 8. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS.ANY Q W SILL SHOWN.SEE Aluminum, 6063-T5 min. 3/8" 0.063" INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF 1"WEEP SHEET 10 FOR a Ill saQ sauas 42 18-8 or 410 THE WINDOW. t A36 Steel 3/8 0.063 NOTCH AT STANDARD SILL. SS Screw EACH END Steel Stud, Gr. 33 min. 3/8" 0.045" (18 Ga) 2)MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE 1/4"MAX. Concrete (min. 3.35 ksi) 1" 1-3/4" 8.ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE \� � . ' �tCEh1Sl ••C'� SHIM 1/4"410 SS CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL �~ •' f�� Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD BUCKS No. 58705 CreteFlex DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER. 1X AND 2X BUCKS P.T. Southern Pine (SG=0.55) 1" 1-3/8" _ (WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER _ ROEQUIRE ANCHORS ° ° ° ° Concrete (min. 2.85 ksi) 1" 1-3/8" LOADS TO THE STRUCTURE.WOOD BUCK DESIGN AND _ 1/4" Steel INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR \ FLANGE OR Ungrouted CMU, (ASTM C-90) 2-1/2 1-1/4 % O °. i�T70r EQUAL-LEG Ultracon ARCHITECT OF RECORD. de FRAME SILLS ° P.T. Southern Pine (SG=0.55) 1" 1-3/8" %,�`�, '40RIDP.•'`�� � A MIN.OF 3 THREADS BEYOND THE METAL SUBSTRATE. 3)VISIBLE LIGHT WIDTH OR HEIGHT(ALSO REFERRED TO AS5��� DAYLIGHT OPENING) IS MEASURED FROM BEADING TO BEADING. �/7 NAB- B)USE ONLY FLATHEAD ANCHORS IN JAMBS.PAN/HEX/FLAT HEAD TYPE IS >I 1 I I I I y 10 t VERTICAL SECTION B-B ALLOWABLE FOR ANCHORS IN THE HEAD. C)"UNGROUTED CMU"VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. A.LYNN MILLER,P.E. P.E.#58705 INSTALLATION DETAILS FOR INTEGRAL FIN FRAMES EDGE EDGE DISTANCE DISTANCE �— EMBEDMENT U � EDGE I � DISTANCE I 1/4"MAX SHIM 1/4"MAX SHIM 5 SASH VISIBLE _� 17 { W MIiB4W2&€ w LIGHT WIDTH ale 4! y`` _ EMBEDMENT ��� 26 19 a L1/4"MAX. EMBEDMENT FIXED VISIBLE —( 2 1 SHIM LIGHT WIDTH nnL �® f30 18 TYP.ANCHOR TYPE, EMBEDMENT AND EDGE FIXED DISTANCE PER SUBSTRATE, 44 ° VISIBLE SEE TABLE 9. LIGHT Qf HEIGHT 31 5 OR 5B 5 — IL 1 BUCK WIDTH 32 HORIZONTAL SECTION C-C TYP.ANCHOR TYPE, ° Y 45 DISTANCE PER SUBSTRATE,UE STRATE,NT AND SEE0-1 O na b TABLE 9.(NAIL SHOWN) p i_Cl O U) DADE APPROVED MULLION, FBC cn w O Q 14 COMPLIANT ALUMINUM/STEEL FRAMING N o=W a}°Q W 1/4"MAX.SHIM ? z OR STEEL STUD.MAY BE VERTICAL OR O HORIZONTAL. SEE SUBSTRATE J �`� W Z z PROPERTIES,TABLE 9, VISIBLE LIGHT FORMULAS: i O ~ W o z CD _ ^ � c4 43 (SHOWN FOR STANDARD SILL;SEE = W N� BUCK 13 SHEET 8 OR 9 FOR HI-RISE SILL) W U 000 —j UNiD (7 ON HEIGHT 63 USE EITHER 1 � Z N Q J SON #10 OR#12 STEEL W SWEEP LATCH @ WIDTH O cc MIDSPAN OR 2 46 55 SELF-DRILLING @ SASH&FIXED LITE: BUCK WIDTH-4.12" o �1 a j SMS(G5), SEE TABLE 9. O � N BOTTOM LOCKS �— z O Z HEIGHT(EQUAL-LITE) Z SASH BUCK HEIGHT/2-3.23" z _O LL VISIBLE INSTALLATION Z) H O LIGHT HEIGHT(PROVIEW) co HEIGHT U OPTION 7 @FIXED LITE: BUCK HEIGHT/2+4.28" ® N w W ANCHORED THROUGH @SASH:BUCK HEIGHT/2-11.43" � (D INTEGRAL FIN INTO METAL = Z z ways HEIGHT(CUSTOM SASH) (n 16 STANDARD SILL @FIXED LITE: BUCK HEIGHT-SASH HEIGHT-2.55" < EXTERIOR SHOWN.SEE @SASH:SASH HEIGHT-4.60" p Q O Z of O 33 SHEET 9 FOR = $ OPTIONAL HI-RISE w W r IJ77—, 1"WEEP 42 SILL. TABLE 9: U J z U) NOTCH AT Q EACH END Anchor Substrate SHI1/4"M Min. Edge Min. a 3u asao sa aas MAX Distance Embedment NOTES: SHIM 2-1/2"x.113" Box Nail P.T. Southern Pine(SG=0.55) 5/16" 2.438 ,, LYE 2-1/2"x.131"Common Nail P.T. Southern Pine(SG=0.55) 3/8" 2.438 1) USE ONLY SUBSTRATE-APPROPRIATE \�� ���' /��� r� ANCHORS LISTED ON TABLE 8.FOLLOW �CEN °• f�� � 2-1/2"x.145" Roofing Nail P.T. Southern Pine(SG=0.55) 3/8" 2.438 EMBEDMENT AND EDGE DISTANCE LIMITS.ANY �` S� 2-1/2"x.145" Roofing Nail P.T. Southern Pine(SG=0.55) 3/8" 2.438 INSTALLATION OPTION SHOWN MAY BE USED TYP.ANCHOR TYPE P.T. Southern Pine(SG=0.55) 1/2" 1.375 ON ANY SIDE OF THE WINDOW. No. 58705 —_ EMBEDMENT AND EDGE EDGE DISTANCE #10 Steel Trusshead Screw or 0.125"Aluminum, 6063-T5 min. 5/16" 0.090 DISTANCE PER SUBSTRATE, #12 Steel, 18-8 or 410 SS 2)VISIBLE LIGHT WIDTH OR HEIGHT(ALSO SEE TABLE 9. 0.050"A36 Steel 5/16" 0.050 REFERRED TO AS DAYLIGHT OPENING)IS (SCREW SHOWN) EMBEDMENT Screw 0.045" 18 Ga Steel Stud, Gr. 33 min. 5/16" 0.0450 MEASURED FROM BEADING TO BEADING. �'•• STATE/F (fie VERTICAL SECTION D-D A)MIN.OF 3 THREADS BEYOND THE METAL SUBSTRATE. 'ONAL A.LYNN MILLER,P.E. P.E.#58705 2.560" 3.185" - 2.060" - 2.848" - 2.848" �-�- .062" 1.125" 062" .062" 2.848" 062" 2.724" r 2.112" 2.724" 2.724" L_ I r"a€"'ecvuems "`plrt re" _ o e 1.489" III����987" 1.125" y 062" 062" 062" + INTEGRAL FIN FRAME p O FLANGE FRAME HEAD O HEAD O EQUAL LEG FRAME HEAD O FLANGE FRAME JAMB INTEGRAL FIN FRAME O5 JAMB O EQUAL LEG FRAME JAMB 2.798" � 2.798" � 2.798" 0 2.798" 2.798" �I 2.798" �I oc) Y 3.008" j 2.841" 3.466" w O na 2.341" 3.508" 4.133" 0 w o O 062" 062' O 0 062" .062" - 062" 062" �- O N o w a}op � Q O M w U) O LL m �� w C) 1.125" _ Lu 7 N gw Z r-- 1.125" U C) O 9uMo p FLANGE FRAME SILL EQUAL LEG FRAME W a0 J oN 7O FLANGE FRAME SILL + O EQUAL LEG FRAME SILL 10 HI-RISE + iz SILL HI-RISE H w m ¢ Q s OINTEGRAL FIN a r a FRAME SILL INTEGRAL FIN FRAME O Z O o z 2.273" -�� O SILL-HI-RISE N - z LL 2.273" �I O 1.300" 120 SILICONE HOT-MELT BUTYL ® N W STRUCTURAL a, J 1/4"NOM. STRUCTURAL 3/16"NOM. POLYISOBUTYLENE (� 170" 2.772" WITH SILICONE = Z ways 2.150" 2.211" 2.105" DESICCANT DEOSICCAAM INT Q TH z Z 062" LL .062" EXT.GLASS O Z O 00 EXT.GLASS w 1.300" (f INT. GLASS INT. GLASS v J X � .062" -� (�- 1.300" Q LLI 70 KODISPACE 4SG TIPS71 SUPER SPACER®NXT TM aril asap sauas is SASH TOP RAIL �a FIXED MEETING RAIL 15 SASH BOTTOM RAIL- is SASH BOTTOM RAIL HI-RISE �ti1lI/ji ®)v LYN/y� ALUMINUM POLYISOBUTYLENE DESICCANT FILL ACEN 1.446' 465" REINFORCEMENT SEAL 5/16"NOM. �.'° SF .6 4" � � .773" �+ SILICONE SEAL 1.522" 040" t ROLL-FORMED _ I�1o• 58705 .062" .627' BUTYL& STAINLESS STEEL = ; 1.235' 040" T802" 802" DESICCANT 813" 802" FOAM ( ;' 44/ 1.370" EXT.GLASS EXT.GLASS ®;<\ STA E F 4(- 1.300" 070" 070" 045" -i Imo- INT.GLASS INT. GLASS leGRIDP.• �\�e i7 SASH SIDE RAIL �$ HEAD COVE ANCHOR �s SASH STOP COVER z5A IG BEAD z5B IG SNAP BEAD zs 1/8"&3/16"BEAD TM //�/®SAL 72 DURASEAL SPACER 73 XL EDGE SPACER A.LYNN MILLER,P.E. P.E.#58705 TABLE 11: Item PGT Part# Description Material 51 ASSEMBLY DETAILS FOR 1 642001 Head, Flange Alum. 6063-T6 FLANGE FRAMES 2 642017 Head, Integral Fin Alum. 6063-T6 (OTHER FRAME TYPES SIMILAR). 3 624028 Head, Equal-leg Alum. 6063-T6 e 4 624004 Jamb, Flange Alum. 6063-T6 4 4A Jamb, Flange(Used For Alternate Radius Top Head) Alum. 6063-T52 1 a 4 5 624020 Jamb, Integral Fin Alum. 6063-T6 51 :,t;t�� t 5A Jamb, Integral Fin (Used For Alternate Radius Top Head) Alum. 6063-T52 3$Y� 6 624031 Jamb, Equal-leg Alum. 6063-T6 6A Jamb, Equal-leg (Used For Alternate Radius Top Head) Alum. 6063-T52 e Prodn Con",I 4o HEAD 7 624002 Sill, Flange Alum. 6063-T6 8 624018 Sill, Integral Fin Alum. 6063-T6 INTERIOR 9 624029 Sill, Equal-leg Alum. 6063-T6 41 10 624003 Sill, Hi-Rise, Flange Alum. 6063-T6 JAMB 11 624019 Sill, Hi-Rise, Integral Fin Alum. 6063-T6 12 624030 Sill, Hi-Rise, Equal-leg Alum. 6063-T6cl 4 14 13 624006 Sash Top Rail Alum. 6005A-T61 14 624005 Fixed Meeting Rail Alum. 6005A-T61 INTERIOR 15 624012 Sash Bottom Rail-Hi-Rise Alum. 6063-T6 �1 16 624068 Sash Bottom Rail Alum. 6063-T6 JAMB w z 0 17 624007 Sash Side Rail Alum. 6063-T6 > 0 FIXED MEETING RAIL 18 624051 Head Anchor Cover Alum. 6063-T6 0 'T O 19 624015 Sash Stop Alum. 6063-T6 � C ao p 25A 624009 IG Bead Alum. 6063-T5 � z U ofQ 0 O 25B 624011 IG Snap Bead Alum. 6063-T5 Uj Z z 26 624013 1/8" &3/16" Bead Alum. 6063-T6 O o _ W 30 6TP247 Glazing Bead, Bulb Vinyl for#624023 Vinyl SASH BOTTOM RAIL = L N Z ~ SASH b U o 31 6TP248 Glazing Bead, Bulb Vinyl for#624009&#624011 Vinyl W — 05 J 'ON 32 724046 Sweep Latch (@ Top Rail) Cast Zlnc 4 o W 'IT ¢ Q 5mo 16 33 624049 Bottom Latch (@ Sill) Alum. 6063-T6 SIDE r— > a F- 34 Setting Block (1/8"X 1/2"X4") Neoprene RAIL z °= o z N 35A IG Setting Block (1/8"X3/4"X4") Neoprene JAMB O U) u_ 35B 724014 IG Snap Setting Block Vinyl Q O 36 724044 Bottom Rail Weatherstrip Extension = I— N LU 37 724053 Sill Gasket Polyethylene 17 ® CN J p 38 724054 Sash Top Rail Gasket Polyethylene Z W aaus 39 724055 Sash Bottom Rail Gasket Polyethylene 37 40 724057 Head Gasket Polyethylene < O Q 41 724063 Meeting Rail Gasket Polyethylene 0 Z) U 00 42 61226D Sash Bottom Rail Bulb Vinyl Polyethylene 06 43 Weatherstrip, .270"X.187", Fin Seal (@ MR) INTERIOR 0 J O U 44 67S16G Weatherstrip, .170"X.270", Fin Seal (@ Sash Side Rail) 39 Q m 45 Weatherstrip, .170"X.187", Fin Seal (@ Top Sash Rail) ai}1 sao sa aas 46 varies Balance with Cover&Trim Rigid Vinyl 51 781 PSQX #8 X 1" PH SMS (Assembly) Stainless Steel 55 7834AA #8 X3/4" Ph. PN SMS (Balance) Stainless Steel SILL TABLE 10: MATERIAL PROPERTIES USED 63 - Alum. Screen with Fiberglass Mesh Varies 51 FOR ANCHORAGE CALCULATIONS: ��.•' �ICEn�s� .l�� 7 Material Min. Fy Min. F ?� 70 - Kommerling Kodispace 4SG TPS No. 58705 71 - Quanex Super Spacer nXT See Sheet Steel Screw 92 ksi 120 ksi 72 - Quanex Duraseal Spacer 11 for INTERIOR 18-8 Screw 60 ksi 95 ksi - Materials 410 Screw 90 ksi 110 ksi 73 Cardinal XL Edge Spacer — '• 51 Elco UltraCon® 155 ksi 177 ksi ATE F A� 74 - Dow 791, 899 or GE 7700 Backbedding Silicone e`�° (0 </\ NOTES: 410 SS Elco CreteFlex® 127.4 ksi 189.7 ksi 11, ' RIDP.. ��� 1 �nJ ALL CORNERS TO USE GASKET AND/OR SEALANT. 6063-T5 Aluminum 16 ksi 22 ksi �i� j • •• e� A36 Steel 36 ksi 58 ksi °�� AL � �\\ Gr. 33 Steel Stud 33 ksi 45 ksi /1/1 1 1 I 1 1 ' 2)SOME PARTS/OPTIONS NOT SHOWN ON DRAWING FOR CLARITY, A. LYNN MILLER,P.E. P.E.#58705