HomeMy WebLinkAboutBlower door testfJ
F
Planning & Development Services
Building Q Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34952
Phone:772-462-2165 Fax.772-462-6443
BLOWER DOOR TEST F®P6911
House Infiltration Test Certleicatlen
Prescriptive and Pel"Wmarice Method
Date. 11 3'/ 2 n z-->
Contractor:
Job Address:
Permit r Q I — UG q 4
r
Construction: ( ,/ MM Construction — Complete
{ ) E„ isiing—A terAddldon
I -louse Infiltration Test Results SLC Climate Zone 2
CFM (50)= 1 31S q/30' Za 1a
Volume = 3 1-1 o Test Date:
ACH (50) =CFM (50) x GO /Volume= -5 -1 Mach pica! Ventilation required less than 3,^CH
Passing results must be & ACH (50) or less
(' ass ( )Fail
FBC,Energy
She building or dwelling unit shall be tested and verined as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(r'), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code ofciaL Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
F C. Residen'cial
Where the air infiltration rate of a dwelling unit is less than —3air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (So Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: Pro -Duct Services
Address: 1915 Pio Vista Drive, Ft. Pierce, FL 34949
1 hereby certifythat the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Matiin Klein
License/Certification #: 5061633