HomeMy WebLinkAboutEnergy CodeComponent Performance Method for Commercial Buildings Form 40.OB-94--
w
ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
1,. Florida Department of Community Affairs
r FLA/COM-94 Version 2.1
,PROJECT NAME_MEDICAL OFFICES____________ PERMITTING OFFICE:
ADDRESS: XXXX MEDWAY ROAD ST. LU.CIE COUNTY
_WHITE'CITY, FL 34987_______ CLIMATE ZONE: _6_________
OWNER.: _DR. WALT RS _ _ PERMIT NO: ---
_------
___
AGENT: �/ � �f Pam, JURISDICTION NO,: _661000______
BUILDING TYPE: _Institutional (Health)_____
CONSTRUCTION CONDITION: New construction
DESIGN COMPLETION: _Finished Building__________
CONDITIONED FLOOR AREA: 5500 NUMBER OF ZONES: 1
- -----------------------
MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 3
COMPLIANCE CALCULATION:
METHOD B
DESIGN
CRITERIA
RESULT
ENVELOPE PERFORMANCE.
52.14
74.19
PASSES
OTHER ENVELOPE -REQUIREMENTS
PASSES
LIGHTING
INTERIOR LIGHTING
11682.00
11925.90
PASSES
EXTERIOR LIGHTING
395.00
2860.00
PASSES
LIGHTING CONTROL -.REQUIREMENTS
PASSES
- HVAC-EQUfiPME-NT-.«��..�_-_---,----'=--------------
�-- - --- --- -.
-- ----- �-- ---
COOLING EQUIPMENT
1. SEER -
10.00
10.00
PASSES
HEATING EQUIPMENT
1. Et-
7.00
N/A
AIR DISTRIBUTION SYSTEM INSULATION LEVEL
• 1. Unconditioned Space
6.00
4.20
PASSES.
WATER -HEATING EQUIPMENT
1. EF
0.88
,0.88
PASSES
PIPING INSULATION REQUIREMENTS
1. Non -Circulating
0.63
0.39
PASSES
----------=------------------=----------------------------------------------
COMPLIANCE CERTIFICATION:
I hereby'cer.tify-that the plans and Review of the plans and specifica-
specifications covered by this calcu- tions covered by this calculation
lation are in compliance with the indicates compliance with the
Florida Energy Ef 'c'ency C de. Florida Energy Efficiency Code.
PREPARED.BY:__ �-.,Before construction is completed,
DATE: - ____ this building will be inspected
for compliance in accordance with
hereby certify that this building i5 Section 553.908, Florida Statutes.
in compliance -with the Florida �Enry BUILDING OFFICIAL:
Efficiency Code. DATE:_____________________________
VWNER/AGENT:__
DATE :----------
I hereby certify(*) that the system -design is in compliance with the Florida
Energy Efficiency Code.
SYSTEM DESIGNER
REGISTRATION/STATE
ARCHITECT
MECHANICAL:
PLUMBING
- ---------------- -------------------------------------------------
ELECTRICAL:
-----------------------------------------------------------------
LIGHTING
Signature is required where Florida law requires design to be performed
by registered desi.gn professionals. Typed names and registration numbers may
be used where all relevant information is contained on signed/sealed plans.
----------------------------------------------------------------------------
BUILDING,INFORMATION'
COMPLI1
CF
401.------GLAZING- -ZONE 1------------------------------------------
------
Elevation Type U SC VLT Shading
Area(Sgft)I
South Commercial 1 .6 1 Continuous Ove
150
East Commercial 1 .6 1 Continuous Ove
42
Total, Glass Area in Zone 1 =
192
Total.Glass Area =
192
402------- WALLS --ZONE I ------------------- ------------------=---------I
Elevation Type U Added R
Gross(Sgft)
----------------------------------------- ------------
North Hvywt. Concrete Wall + 8" Concre 0.187 6
-----------
936
East Hvywt. Concrete Wall + 8" Concre 0.187 6
558
South Hvywt.,Concrete Wall + 8" Concre 0.187 6
936
West,• Hvywt. Concrete Wall, '+ 8" Concre 0.187 6
558
Total Wall Area in Zone .1 =
2988
Total Gross Wal'1 Area =
2988
403.----7-DOORS--ZONE 1---------------------------- --------------------
Elevation Type U
Area(Sgft)
South 2.0' STOREFRONT .9
42,
North-' 1-3/4-Steel Door -Solid mineral fiberboa 0.38
21
Total Door Area in Zone 1 =
63
Total Door Area =
63
_404.------.ROOFS--ZONE 1 ------------------------------------------------
Type Color .0 Added R
------------------------------------
Area(Sgft)
------ ------------
--STL DECK- -W%-4"-FO-AM^BD--INSL/N---' ---Light-'-0.09-0- - 19
----------
y -` -2a-40
` STL DECK W/4" FOAM BD INSL/N Light 0.090 19
3224I,
Total Roof Area in Zone 1 =
5564'
Total Roof Area =
5564
405.------FLOORS-ZONE 1------------ :------------- .-------------------------
' Type, R
Area(Sgft)
Slab on Grade/Uninsulated 1
2340
Slab on Grade/Uninsulated 1
3224
Total Floor Area in Zone 1 =
5564
Total Floor Area.=
5564
406------- INFILTRATION --------------------------------------------------
CHECK
Infiltration Criteria in 406:1.ABC.1 have been met.
1
407.= ----- COOLING SYSTEMS --------------------------------------------------
- Type No Efficiency IPLV
`
Tons
--------------=------------- ------------- -------------------
1. Split, System 2 10 .11
0.00
408------- HEATING SYSTEMS-----------------------------------------------
Type No Efficiency
BTU/hr
1. Electric Resistance 2 7
34000
409.------VENTILATION ----------------------------------------------------
"
•
CHECKVentilation
Criteria in 409.1.ABC.1 have been met.
J
410.-----AIR DISTRIBUTION SYSTEM-- ---- ----------------------------------
.'AHU Type Duct Location.
R-value,
a
1,. Split / PTAC Air Conditioner Unconditioned Space
6
41'1------ PUMPS AND 'PIPING -ZONE• I ----------------------------------------
Type R-value/in Diameter
Thickness,
1. Non -Circulating 6 .75
.625
412 ------ WATER HEATING SYSTEMS -ZONE I -----------------------
-----------
Type Efficiency StandbyLoss InputRate
--------------------------------------------
Gallons
----------
1 kW .88 .2 .88
----------
40
413.-----ELECTRICAL POWER DISTRIBUTION----------------------------------
CHECKMetering
criteria in 413.1.ABC.1 have been met.
Transformer criteria in 413.1.ABC.2 have been met.
414.=----MOTORS ----------------- =----------------------------------
---
Motor efficiencies in 414.1:ABC.1 have been met.
415.-----LIGHTING SYSTEMS -ZONE 1---------------------------------------
Space Type No Control Type 1 No Control Type 2 No Watts
Area(Sgft)
General Ar• 1 On/Off 8 4914
2340
General Ar 1' On%Off 11 6768
3224
Total Watts for Zone 1 =
11682
Total Area -for Zone 1 =
5564
Total.Watts =
11682
Total Area =
5564
ICHECK I
.Lighting criteria in 415.1.ABC have been meta
------------------------------------------------------------------
16. HVAC,load sizing -has been performed. (407.1":-ABC.1)
-----------------------------------------------------------
17,.-Duct sizing and design'have been performed. (410.1.ABC.1.2)
-------=----------------=-----------------------------------------
18. Testing and balancing will be,performed. (410.1.AB,C.4)
--------------------------------------------------------------
19. Operation/maintenance manual will be provided to-owner.(102.1)
iNCE
[ECK,